Loading...
BRES2018-000778-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type/Subtype: Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: MCCLURE HOMES LLC 52765 CLARET COVE LA QUINTA, CA 92253 Twr4 4 Ru;qrw DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT BUILDING RESIDENTIAL/DWELLING - SINGLE FAMILY DETACHED BRES2018-0007 81560 SHACKLETON WY 767870024 MCCLURE HOMES / 7,267SF DWELLING/VB/RES-3/CLASS A-FR/13D $653,114.20 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Owner: MCCLURE HOMES LLC 52765 CLARET COVE LA QUINTA, CA 92253 D ZZ\, U D Contractor: WHALL CONSTRUCTION MAY 14 2010 1494 AVOCADO ROAD OCEANSIDE, CA 92054 _P D CITY OF LA QUINTA (619)787-2276 DESIGN & DEVELOPMENT DEPARTMENT Llc. No.: 733556 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: L nse No.: 733556 .r f/ Date: f LCon[ractoe: I OWNER -BUILDER D LARAWN I hereby affirm under penalty of perjury that I exempt from the Contractor's State License Law for the following reason (Sec. 7VA.5, Business and Professions Code: Any city or county that requires a permit to co ruct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Date: 5/13/2019 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is Issued. workers' compensation insurance carrier and policy number are: Carri M Policy Number: _ I certify that in the performance of the work for which this permit is issued, I s dt employ any person in any manner so as to be me subject to the workers' co nsation laws of California, and agree that, if I ould become e workers' compensation provisions of Section 37 r Code, I shall forthwith comply with thus prov' ions. G Date: ( Applicant: WARNING: FAILURE TO SECURE WORKERS' OMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO C MINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance ofthis permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work For 180 days will subject permit to cancellation. certify that I have read this application and state that the above infor atinn is correct. agree to comply with all city and county ordinances and state laws ating to building :onstruction and Pereby authorize representatives of this er upon the 'Rent ion edilopoty far inspection purposes. Lender's Address: Date: �' . jSignature (Applicant or � Date: 5/13/2019 Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: MCCLURE HOMES LLC 52765 CLARET COVE LA QUINTA, CA 92253 BRES2018-0007 81560 SHACKLETON WY 767870024 MCCLURE HOMES / 7,267SF DWELLING/VB/RES-3/CLASS A-FR/13D $653,114.20 Owner: MCCLURE HOMES LLC 52765 CLARET COVE LA QUINTA, CA 92253 Contractor: WHALL CONSTRUCTION 1494 AVOCADO ROAD OCEANSIDE, CA 92054 (619)787-2276 Llc. No.: 733556 Detail: 1,854SF DWELLING - [VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES NOT INCLUDE POOLi SPA, BLOCK WALLS OR DRIVEWAY APPROACH. A FINISH FLOOR ELEVATION CERTIFICATION BY A LICENSED SURVEYOR,OR ENGINEER IS REQUIRED PRIOR TO FOUNDATION INSPECTION. 2016 CALIFORNIA BUILDING CODES. FINANCIAL INFORMATION DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($104.55) DESCRIPTION ACCOUNT CITY AMOUNT PLAN CHECK/PERMIT EXTENSION PROCESSING 101-0000-42600 0 $107.27 DESCRIPTION ACCOUNT CITY AMOUNT PLAN CHECK/PERMIT EXTENSION PROCESSING 101-0000-42600 0 $104.55 Total Paid for ADMINISTRATIVE: $107.27 DESCRIPTION ACCOUNT CITY AMOUNT ART IN PUBLIC PLACES - RESIDENTIAL 270-0000-43201 0 $1,132.78 Total Paid for ART IN PUBLIC PLACES - AIPP: $1,132.78 DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $27.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $27.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - CIVIC CENTER 252-0000-43200 0 $942.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF- LIBRARIES 253-0000-43200 0 $344.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - PARKS/REC 251-0000-43200 0 $2,048.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 DESCRIPTION ACCOUNT CITY AMOUNT TEMP POWER SERVICE 101-0000-42403 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT TEMP POWER SERVICE PC 101-0000-42600 0 $18.20 Total Paid for ELECTRICAL: $44.21 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0 $92.82 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF, PC 101-0000-42600 0 $38.22 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $156.04 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $51.49 Total Paid for ELECTRICAL - NEW CONSTRUCTION: $338.57 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT >7KSF 101-0000-42408 0 $39.01 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT>7KSF PC 101-0000-42600 0 $195.05 Total Paid for GRADING: $234.06 DESCRIPTION ACCOUNT CITY AMOUNT CONDENSER/COMPRESSOR 101-0000-42402 0 $195.05 DESCRIPTION) ACCOUNT CITY AMOUNT CONDENSER/COMPRESSOR PC 101-0000-42600 0 $130.05 DESCRIPTION ACCOUNT CITY AMOUNT EXHAUST HOOD 101-0000-42402 0 ter y.rv.v n0 DESCRIPTION ACCOUNT CITY AMOUNT EXHAUST HOOD PC 101-0000-42600 0 $10.40 DESCRIPTION ACCOUNT CITY AMOUNT FURNACE 101-0000-42402 0 $195.05 DESCRIPTION ACCOUNT CITY AMOUNT FURNACE PC 101-0000-42600 0 $130.05 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN 101-0000-42402 0 $130.00 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN PC 101-0000-42600 0 $52.00 Total Paid for MECHANICAL: $868.60 DESCRIPTION ACCOUNT CITY AMOUNT NEW CONSTRUCTION PERMIT 101-0000-42400 0 $902.66 Total Paid for NEW CONSTRUCTION PERMIT: $902.66 DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($1,095.45 ) DESCRIPTION ACCOUNT CITY AMOUNT NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $809.45 DESCRIPTION ACCOUNT QTY AMOUNT NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $1,095.45 Total Paid for NEW CONSTRUCTION PLAN CHECK: $809.45 DESCRIPTION ACCOUNT CITY AMOUNT PLAN CHECK DEPOSIT- RESIDENTIAL 101-0000-42600 1 $1,200.00 Total Paid for PLAN CHECK DEPOSIT - RESIDENTIAL: $1,200.00 DESCRIPTION ACCOUNT CITY AMOUNT BACKFLOW DEVICE 101-0000-42401 0 $13.00 DESCRIPTION ACCOUNT CITY AMOUNT BACKFLOW DEVICE PC 101-0000-42600 0 $5.20 DESCRIPTION ACCOUNT CITY AMOUNT BUILDING SEWER 101-0000-42401 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT BUILDING SEWER PC 101-0000-42600 0 $18.20 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $338.00 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $338.00 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 5+ OUTLETS 101-0000-42401 0 $39.01 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 5+ OUTLETS PC 101-0000-42600 0 $26.01 DESCRIPTION ACCOUNT CITY AMOUNT ROOF DRAIN 101-0000-42401 0 $117.00 DESCRIPTION ACCOUNT CITY AMOUNT ROOF DRAIN PC 101-0000-42600 0 $117.00 DESCRIPTION ACCOUNT CITY AMOUNT WATER HEATER/VENT 101-0000-42401 0 $26.00 DESCRIPTION ACCOUNT CITY AMOUNT WATER HEATER/VENT PC 101-0000-42600 0 $15.60 Total Paid for PLUMBING FEES: $1,079.03 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 $20.00 Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $20.00 DESCRIPTION ACCOUNT CITY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $84.90 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $84.90 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 DESCRIPTION ACCOUNT CITY AMOUNT SINGLE FAMILY DETACHED 224-0000-20320 0 $1,837.44 Total Paid for TUMF - RESIDENTIAL: $1,837.44 TOTALS::4 PERMIT # V�92't)t v PLAN LOCATION: O'D lYl��Sp a Gfv�J 41ee Project Address: g�•--5� h k! i► zr, 7-64 Project Description: Pool Remodel Add't Elect, Plumb Mech J P ' ' ' APN p� Applicant Name: 0 G (/lore, He 05 aa,7 / •-Q/ ti•raL �l Address: L101 P S / 27 City, ST, Zip: Telephone: f2a Email: M �Ar �- /-V% Valuation of Project $ Contractor Name: New SFD Construction: Address: Conditioned Space SF City, St, Zip Garage SF Telephone: Patio/Porch SF Email: Fire Sprinklers SF State Lie:- City Bus Lie: Arch/Eng Name: Construction Type: Occupancy: Address: Grading: City, St, Zip Bedrooms: Stories: # Units: Telephone: Email: State Lie: City Bus Lie: Property Owner's Name: !' :2 New Commercial / Tenant Improvements: Address: S `��-,-- V Total Building SF City, ST, Zip "n Construction Type: Occupancy: Telephone: -- S O J Z f� Email: �Ola•`f L/� �i 50 M a,' can �I J 78495 CALLE TAMPICO LA QU I NTA, CA 92253 760-777-7000 OFFICE USE ONLY # Submittal Req'd . Req'd Plan Sets Structural Calcs 2 Truss Calcs Title 24 Calcs 2— Soils Report �^ Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT; LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMIIND. AMOUNT: DATE: R CGI Et . INITIALS MAY 1 3 2019 ' CERTIFICATE OF COMPLIANCE J (California Education Cod ��IC2�0)__n �� � �� Project Name: McClure Homes LLC —Madison Club [? Aw1Yy QW9 019 Owner's Name: McClure Homes LLC Phone No. 858-414-0490 Project Address: 81-560 Shackleton Way, LaQuinta Project Description: SFD APN: 767-870-024 Tract #: Lot #'s: 48B Type of Development: Residential XX Commercial Industrial Total Square Feet of Building Area: 7,267 sq. ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to *n on behalf of the owner/developer, Dated: May 13, 2019 Signature: ********************************************************************* SCHOOL DISTRICT'S REQUIREMENTS FOR TI ,ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code 17620 Number of Sq.Ft. Amount per Sq.Ft. Amount Collected Gov. Code 65995 7267 $3.79 $27541.93 Project Agreement Existing Not Subject to Fee Approval Prior to 1/1/87 Requirement Building Permit Application Completed: Yes/No By: Larry Moen, Director Facilities Dev. & Planning Note: Pursuant to AB 181 any room additions or enclosures of 500 sq. ft. or less are exempt from developer fees. Any mobile homes being relocated within the same school district's jurisdiction are exempt from developer fees. Certificate issued by: Laurie Howard, Administrative Spec. Signature: A)k� NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90-day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90-day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. 11/2010 Recording Requested by: FNTG ,Builder Services RECORDING REQUESTED BY First American Title Company MAIL TAX STATEMENT AND WHEN RECORDED MAIL DOCUMENT TO: Mark McClure and Doren McClure 52647 Via Savona La Quinta, CA 92253 DOC # 2016-0151143 04/15/2016 03:58 PM Fees: $30.00 Page 1 of 6 Recorded in Official Records County of Riverside Peter Aldana Assessor -County Clerk -Recorder "'This document was electronically submitted to the County of Riverside for recording" Receipted by: SOPHIA #466 Space Above This Line for Recorder's Use Only GRANT DEED A.P.N.: 767-870-024-5 - —! T.R.A. No.020-172 The Undersigned Grantor(s) Declare(s): DOCUMENTARY TRANSFER TAX $825.00; CITY TRANSFER TAX $0.00; X computed on the consideration or full value of property conveyed, OR computed on the consideration or full value less value of liens and/or encumbrances remaining at time of sale, unincorporated area; [ X ] City of La Quinta, and File No.: RIW-5132527 (SE) FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Terrence J. Rose and Trudy A. Rose, Trustees of the Terrence and Trudy Rose 1979 Living Trust dated 05/14/1979 hereby GRANTS to Mark McClure and Doren McClure, husband and wife as joint tenants, as to an undivided 25.64% interest and Equity Trust Company custodian FBO Mark McClure IRA, as to an undivided 74.36% interest, as tenants in common the following described property in the City of La Quinta, County of Riverside, State of California: Legal description per Exhibit "A" Mail Tax Statements To: SAME AS ABOVE DOC #2016-0151143 Page 2 of 6 Grant Deed - continued Date: 03/29/2016 Dated: March 29, 2016 Terrence J. Rose and Trudy A. Rose, Trustees of the Terrence and Trudy Rose 1979 living Trust da d Q5114/1979 Terrence J. Rose, Trustee Trudy A. Rase, Trustee A notary public or other officer completing this certificate verifies only the identity of the individual who signed the document to which this certificate is attached, and not the truthfulness, accuracy, or validity of that document. STATE OF 4YU )SS COUNTY OF ) On Mad (3U, Re _ before me, Ka lc� l*f1&ja , Notary Public, personally appeared T-e�r�r►�ecl . � who proved to me on the basis of satisfactory evidence to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. 4�AMRI 1 I certify under PENALTY OF PERJURY under the laws of the State of-Gali€emie that the foregoing paragraph is true and correct. WITNESS my hand and y rtg ayf r�'rr 00""' 1 o# This area for official notarial seal. 140.,4411 Page 2 DOC #2016-0151143 Page 3 of 6 Grant Deed - continued Date: 03/29/2016 Dated: March 29, 2016 Terrence J, Rose and Trudy A. Rose, Trustees of the Terrence and Trudy Rose 1979 Living Trust da d 05/14/1979 Terrence J. Rose, Trustee J!!� � '- 149m� - - Trudy A. Rvse, Trustee A notary public or other officer completing this certificate verifies only the identity of the individual who signed the document to which this certificate is attached, and not the truthfulness, accuracy, or validity of that document. STATE OF 49r, )SS COUNTY OF On ..lWggfi (30, ad go before me, KQt W /1!!i , Notary Public, personally appeared who proved to me on the basis of satisfactory evidence to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. 4ia+tiQl1 I certify under PENALTY OF PERJURY under the laws of the State off that the foregoing paragraph is true and correct. WITNESS my hand and "WWQ"^101oyfl3ll� l � Doc. Deli o bl/ L # Pages: 3 NOtery Nww Kelso Warfield 3rd Circuit Doo. Deecriptiom Notary Signature This area for official notarial seal. DOC #2016-0151143 Page 4 of 6 Grant Deed - continued Date: 03/29/2016 A notary public or other officer completing this certificate verifies only the identity of the individual who signed the document to which this certificate is attached, and not the truthfulness, accuracy, or validity of that document. 1. STATE OF )SS COUNTY OF On 20 ( before me, e&�M r� , Notary Public, personally appeared who proved to me on the bMis of satisfactory evidence to be the persons) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of Ca4fernia that the foregoing paragraph is true and correct. WITNESS my hand and LOMWVf'A Y1 +rfrJ 07113 [I: �pIF'O r� This area for official notarial seal. Page 3 DOC #2016-0151143 Page 5 of 6 Grant Deed - continued Date; 03/29/2016 A notary public or other officer completing this certificate verifies only the Identity of the individual who signed the document to which this certificate is attached, and not the truthfulness, accuracy, or validity of that document. 1. STATE OF)SS COUNTY OF ) On 1!56 f 2-0 (� �T before me, �"�ifi , Notary Public, personally appeared TrctAA& -A- Ar3e, who proved to me on the b8is of satisfactory evidence to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/thelr authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument, I certify under PENALTY OF PERJURY under the laws of the State of � that the foregoing paragraph is true and correct. WITNESS my hand and WmPase-I1 1,1pird 0711-3It i PA" r— J N This area for official notarial seal. ov 400 ;" ooalD�he �tG 6talldelt� Notary Nm IK" YYllrflyd W Coed Page 3 Exhibit "A" DOC #2016-0151143 Page 6 of 6 Lot 3 of Tract No. 34969, in the City of La Quinta, County of Riverside, State of California as per map recorded in Book 430, Pages 3 through 9 inclusive of Maps, in the office of the County Recorder of said County. Excepting from a portion of said land all water, minerals, oil, gas, petroleum, other hydrocarbon substances and all geothermal energy sources in or under said land or which may be produced from said land as excepted by East of Madison, LLC, a Delaware limited liability company in the deed to The Madison Club Owners Association, a California nonprofit mutual benefit corporation, recorded on December 3, 2009 as Document No. 2009-06244810 of Official Records, in the office of the County Recorder of said county. Q12Es�I,g_�,,o07 CITY OF LA QUINTA SUB -CONTRACTOR LIST JOB ADDRESS �156o 5W)UPERMIT NUMBER OWNER, -BUILDER Qn5A This form shall be pQster on the job with the Building Inspection Card at all dimes in a_ conspicuous place. Only persons appearing on this list or their employees are authorized to work on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance of hitilriinn narmit Fnr aar.h annlirnhle trade. all infnrmntinn rRnuestPd helow must be rmmnleted by anolicant. "On File" is not an acceptable response. Tradef Classification J Contra tar .. .-.-. Sxate,G - ' ntractar's License... Workers-Gom..pen.s..ati.an Insurance City ,business License Carrier Name Policy Number Exp. Date License Number Exp. Date (e.g. State Fund, CalComp) (Format Varies) (xx/xx/xx) (xxxx) (xx/xx/xx) Company Name Classification (e.g. A, B, C-8) License Number (xxxxxx) Exp. Date (xx/xx/xx) EAIRTH:WOAK (:C-12): Ma-/-� l; 96 5, 2 -? CONCRETE (C=8) FRAMING (C-5) STRUGT. STEEL (C=51) MASONRY (C-29:) PLUMBING (C-86) �-\E.c.`k-.,`C \ .��er- �-+_+ LATH, :PLASTER:-(:C-35) DRYWALL (C-9) HVlkC (C-20) MAY 14 2019 ELECTRICAL (C=T.0) `.� �-.�� 1 c�� C- l O i".y y 3 ?-o CITY OF LA INTA T ROOFING (C-39) DESIGN A ID DEVELOPMENT DEPARTMENT SHEET METAL (C-43) FLOORING (C-15). GLAZING (C-17) INSULATION (C-2) SEWAGE DISP:(C-42): PAINTING. (C-33) CEFiAMI:C TILE (:C-54:) CABINETS (C-6): FENCING :(CA 3) LANRS.CAPING (C-27) POOL (C-53) EsG11 DATE: 06/ 15/ 18 ❑ APPLICANT �URIS. JURISDICTION: LA QUINTA PLAN CHECK #.: BRES2018-0007 SET: III PROJECT ADDRESS: 81-560 SHACKLETON WAY PROJECT NAME: NEW SFD FOR McClure HOMES LLC LOT 48B(STRUCTURAL ONLY) ❑ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. ® The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. ❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ❑ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. ❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: ® EsGil staff did not advise the applicant that the plan check has been completed. ❑ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: ems— Telephone #: Date contacted: y: Email: Mail Telephone Fax In Person ® REMARKS: Have civil engineer note on sheet SD-6, that detail 19 is applicable to the required guard rail system located on stairway. By: Javier Snider (BD) Enclosures: EsGil 06/15/18 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 33 �C3 Zo 1 F CITY OF LA QUINTA - PUBLIC WD KS D ZPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated & effective 9/25/2009 Green Sheet approvals are forwarded to the Building & Safety Department directly by Public Works. Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed below are complete. Incomplete applications or applications which cannot be processed will be returned to applicant. Date: 'J / 01 1_Developer: �i��fl��-^y��� uc�'� C-�`�'t��K Tract No.: 3301 - 2 Tract Name: .� `` J 0 r• ('T"l 3 y q fcq Lo+3 d No.{s): � � Address(s): $1-S >O S�v��-k�t,�� Phone Number: (�60) 7�3�SZ�1 I 1 The following are the requirements for Public Works Clearance to authorize issuance of a building permit from the Building & Safety Department: ❑ CUSTOM HOMES: PROVIDE ITEMS #2, #3, #4 #5 & #7 BELOW ❑ TRACT HOMES: PROVIDE ITEMS #1, #2, #3 & #5 BELOW ❑ COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1, #2, #3, #5 & #7 BELOW ❑ WALLS, SIGNS, OTHER: PROVIDE ITEM #6 BELOW 1. Attach Pad Elevation Certificates in compliance with the approved design elevation for building pad (maximum allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of current date). If a precise grading plan creates the pad for approval, please withhold green sheet submittal until a Pad Elevation Certificate can be provided. Attach geotechnical certification of grading plan compliance including compaction reports from a licensed Soils Engineer. Recently rough graded residential developments which have a previously approved geotechnical certification are exempt from this requirement. Attach recorded final map or title information/grant deed showing proposed building locations are legal lots. Complete the attached <1 acre per lot or infill project Fugitive Dust Control project information form, PM10 plan & agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy plan. PM10 plans for commercial & residential developments (beyond 1 lot) are submitted separately with grading plans & are subject to additional requirements. A current PM10 certification number is required. PAttach a copy of the rough or precise grading plan to the Public Works Department showing building location(s) for pad elevation verification. AO flood zone developments will require an approved flood plain development plan. T�Attach supporting documentation for wall plan, monument sign, grease trap or special facility installations. Complete and sign the attached water quality management plan (WQMP) exemption form, if applicable. PW approved building construction projects require either a WQMP or a completed WQMP exemption form. Approved maps/plans may be viewed at the following link: http://www.la-guinta.org/PlanChecklm search.aspx I have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to my findings, the above project may be released for building permit issuance. This section completed by City staff. I Recommended by: Date: �/ 1 l+ 1 / It Public Works Distribution: ( ✓) Green Sheet to Building & Safety ( ) Green Sheet to Planning Department Declined for approval for reason(s) as follow(s), please correct and resubmit: T:1Checklists - Forms & ApplicationslFonns & Applications\GREEN SHEET cover & PM10 less than 1 Acre Revised 10-02-12.doc City of La Quinta - PM10 Fugitive Dust Control Project Information Construction Phase PM10 Agreement (<1 acre/lot or Infill Project) Project Information Pro'ect Contractor: Project Phase (check one) ❑ • Construction ❑ Demolition Project Name: M'_Ct0 --i (4`6 Project Tract/Lot Numbers: CUO CL Project Street Address: Total Acres in Active Construction (<1 acre per Lot)' Anticipated Start Date: L'i « Anticipated Completion Date: L{ / 1 /I -'rx Please note: Dust control is required 24 hours a day, 7 days a week, regardless of construction status. Person listed below is responsible for dust control during business and non -business hours. r Sv �� In a-�• �ti� PM10 Contact Information Name: Title: Company Name: 1� i c o.� ,c. u ;� Ci...'r ►�� Mailing Address: 3 " %� ��•��� ��" V'/ L city, State, ZIP Code: l_... o; ,- V .. G 'rI LZ Primay, Phone M 0 - Vt Fax #: 72b 0 - 35- 6570 -LiD (plat- 24 Hour Emergency Phone#: Cell Phone M & t 'k -'7rZ - Z2 •i Email Address: C t")t�14` V\4 (lG • L, "'� PM10 Certificate #: CV t 601 •0030 -6 -16 The above stated property owner (or authorized representative): ❖ Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to SCAQMD Rules 403, 403.1, 401, 402, 201, 203 and PERP; ❖ Shall constitute an Agreement to comply with all project conditions as identified in the approved dust control plan. ❖ Acknowledges that dust control is required twenty-four (24) hours a day, seven (7) days a week, throughout the period of project performance, regardless of project size or status; ❖ Shall ensure that each and every contractor, subcontractor and all other persons associated with the project shall be in continuous compliance with all requirements of the approved dust control plan; ❖ Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the dust control plan are necessary; ❖ Shall authorize representatives of City/County to enter the property for inspection and/or abatement purposes; ❖ Shall hold harmless the City/County and its representatives from liability for any actions related to this dust control plan or any City/County initiated abatement activities. A _- SignatVre oYProjkerty Owner or Authorized Representative h 19 Date City of La Quinta - PM10 Fugitive Dust Control Plan (<1 acre per Lot or Infill Project) This Fugitive Dust Control Plan shall take into account applicable SCAQMD Regulations Rule 403, 403.1, 401, 402, 201, 203 and Portable Equipment Registration Program (PERP). ❖ WATERING: Continuous watering is required to prevent dust and must occur a minimum of four (4) times daily. Water shall be applied from an adequate sized metered water source to dry soils to prevent: ■ Visible dust emissions >20% opacity ■ Visible dust emissions that travel >100 feet from the source (within site) • Visible dust emissions that cross any property line ❖ EDUCATION: The responsible dust control Individual and key personnel shall attend SCAQMD PM10 class and obtain PM10 certificate number prior to construction activity (training information may be obtained by contacting SCAQMD at (909) 396-2183). ❖ CONSTRUCTION & DEMOLITION ACTIVITIES: A copy of this approved Fugitive Dust Plan must be kept on site. At least one short-term stabilization method must be used during off hours. At least one long-term stabilization measure must be used within ten (10) days of ceasing activity. ❖ WEATHER MONITORING: Wind predictions shall be monitored. ❖ SIGNAGE: Approved signs shall be installed at a highly visible location. Please refer to the Coachella Valley Fugitive Dust Control Plan Handbook for Construction Signage Guidelines. ❖ TRAFFIC: Construction traffic shall not be allowed on the pad, unless absolutely necessary. If vehicles operate on pad, pad shall be kept firm and moist through hose watering and sprinklers; and a maximum traffic speed of 15mph will be enforced. Fugitive Dust shall be prevented by fencing off site to prevent unauthorized traffic on pad. ❖ PARKING: Parking is not allowed on pad. All vehicles must park on street at designated areas only. ❖ TRACK OUT: Provide 24 hour street cleaning and track out system as approved by City Public Works inspectors. No dirt on public or private roads. Track out shall be cleaned up within one (1) hour of incident and at the conclusion of each workday. ❖ DIRT PILES: Dirt piles shall be limited to 50 cubic yards and built per California Building Code grading requirements. Piles shall be kept moist or covered with tarp material. Larger dirt piles will require stockpile or grading permit. ❖ FENCING: Provide PM10 fencing at perimeter of public roads and where applicable. Wood slat fencing can be installed at rear of property and return 20 feet on either side if HOA restrictions apply. Block walls can replace PM10 fencing during the construction phase. ❖ EQUIPMENT: Extra hoses and sprinklers shall be maintained on site. ❖ EXCAVATION MEASURES: All areas to be excavated or graded shall be pre -watered. Water shall also be applied during excavation or grading operations. ❖ DUMP TRUCKS: Open top dump trucks shall be wet down, moist and covered with a tarp prior to leaving site. ❖ INACTIVE SITE: Within 10 days of ceasing of activities, re -vegetate or permanently stabilize as required. ❖ RECORD KEEPING: Fugitive Dust Control Plan records (i.e. self inspection records, records of use of chemical suppressants, etc.) shall be maintained for 3 years by the Property Owner (or Authorized Representative). Property Owner shall notify the City and SCAQMD within 10 days of completion of project. Water Quality Management Plan (WQMP) Exemption Form - Whitewater River Region Documentation of Project Not Requiring a WQMP but Requiring Site Design BMPs and Source Control BMPs by Entitlement Conditions of Approval or Permit Conditions - WQMP Required for the Listed Change of Land Uses or for Changes of Pollutant Stream (All Questions Below Must be Answered "No" To Exempt Project) Entitlement or construction of new single-family hillside residence(s) that create 10,000 square feet, or more, of impervious area where the re -development natural sl❑ a is 25% or rester? Yes ` No X Entitlement or construction of new single-family hillside residence(s) that create 10,000 square feet, or more, of impervious area where the pre -development natural slope is 10% or greater where erosive soil conditions are known? _ Entitlement or construction of new commercial and industrial development(s) of 100,000 square feet or more? Entitlement or construction of new automotive repair shop(s) including body, upholstery, paint, exhaust, tire, transmission, engine or other automotive specialty repair. [Standard Industrial Classification (SIC) codes 5013. 7532, 7533, 7534, 7537, 7538, and 7539 ? u / Entitlement or construction of new retail gasoline outlet(s) disturbing greater than 5,000 square feet? Entitlement or construction of new restaurant(s) (or potential restaurant shell space) disturbing greater than 5,000 square feet? Entitlement or construction of new home subdivisions with 10 or more housing units? Entitlement or construction of new parking lot(s) of 5,000 square feet or more, or with 25 or more parking spaces, and potentially exposed to Urban Runoff? Applicant Information Name and Title ea 4t_ c -�; t.. Company 1 ; Phone Email ,,,�„�� t G�..rtr yo: ��S c.. c,d -►. Project Information Project Name 0,4-LC "— �rS3 Type (SFH, Multi -Family, Commercial, Etc.) F tA Location or Street Address I , 5-(6 DcJ- Nearest Cross Streets �{ ri +�►t., Via., Municipality/County/Zip Code La Quinta Tract Number(s) and/or Assessor Parcel Number(s) 3 O�{fl. Z 6 . 1'1 p• C> Lq Other Location Information Watershed Whitewater River Source Control BMP Information Size of Project Area (nearest 0.1 acre) S Project Area managed with Site Design or Low Impact Development (LID) BMPs (nearest 0.1 acre) _ 31 Is the project subject to onsite retention by City ordinance or policy? 10 p Name of the Entity that will implement, operate, and maintain the Source Control BMPs r Contact Name Street or Mailing Address (o ,t �,.,.�� }- 'N J €, City ��, •` Zip Code G(-L►LX—) Phone 7 0 - 57 — S VI Check Item To be Performed Source Control BMP Requirements - All Projects Require Non -Structural BMP Source Control Non -Structural BMP (See Appendix H, Section 4.5.2.1) Ongoing Irrigation System and Landscape Maintenance ✓ Ongoing Litter Control Ongoing Drainage System Inspection & Maintenance Education/Training for Property Owner, Operators, Occupants, or Employees ✓ Activity Restrictions — Prohibition of Debris Blowing/Sweeping/Washing into Street/Storm Drain, Closed Trash Lids, Restriction of Vehicle Washing Ongoing Street Sweeping at Private Streets and Private Parking Lots Check Item To be Provided Source Control BMP Requirements — Small Sloped Lots, Small Commercial, <10 Unit Subdivisions, <5,000 Square Ft. Parking Lots, Etc. Structural BMP (See Appendix H, Section 4.5.2.2) Storm Drain Inlet Stenciling and Signage Landscape and Irrigation System Design to Minimize Erosion & Nuisance Runoff Protection of Slopes and Channels to Minimize Erosion Multi -Family Project Use of Community Car Wash Racks Wash Water Controls for Food Preparation Areas to Use Sanitary Sewer Fueling Area (Design & Maintenance) Including PCC Surface, Canopy & Spill Prevention Air/Water Supply Area Drainage (Design & Maintenance) Including Spill Area Containment Trash Storage Areas (Design & Maintenance) Including Attached Lids, Storm Water Controls I Loading Docks (Design & Maintenance) Including Storm Water Controls, Dry & Frequent Cleaning Procedures Maintenance Bays (Design & Maintenance) Including Indoor Location & Storm Water Containment Vehicle and Equipment Wash Areas (Design & Maintenance) Including Canopy & Containment Outdoor Material Storage Areas (Design & Maintenance) Including Canopy & Containment Outdoor Work Areas or Processing Areas (Design & Maintenance) Including Canopy & Containment CC&R's, Maintenance Agreements or Other mechanisms will be used to ensure the ongoing operation, maintenance, funding, transfer and implementation of the project -specific WQMP requirements. Legal description and plat stamped by Registered Surveyor to be attached to the applicable CC&R or Maintenance Agreement for recordation at Riverside County. (Optional Requirement to be reviewed on a Project by Project basis) BMP Acknowledgement The applicant shall comply with listed BMPs and applicable provisions of the City's NPDES stormwater discharge permit, LQMC Sections 8.70.010 et seq. (Stormwater Management and Discharge Controls), and 13.24.170 (Clean Air/Clean Water); Riverside County Ordinance No. 457; the California Regional Water Quality Control Board —.Colorado River Basin Region Board Order No. R7-2008-0001 and the State Water Resources Control Board's Order No. 99-08-DWQ. Signature: ~ Print Name: fejl K Title: ��' _r h • `t �' Date: S ! 1 f Phone: ( Ic 3 53 Zl 1 Applicant Certification I certify that I have read this'form in its entirety and understand the City's submittal and review process and the requirements for this form. I understand and agree that if during the processing of the form, it is determined the information contains errors or omissions, clarification and/or supplemental information may be required and the preparation of such information may be considered, in the Community Development Director's judgment, an unreasonable delay and will result in a suspension of processing time limits in accordance with the California Code of Regulations, Title 14, Section 15109. Signature: U —4k)� w��•r Print NameZFr.(t `� ..: �� `! 04 Title:�`0 Date: r I ( I t Y Phone: ( 0 - 3 Owner Certification I certify under the penalty of the laws of the State of California that I am the property owner of the property that is the subject matter of this application and I am authorizing and hereby do consent to the filling of this application and acknowledge that the final approval by the City of La Quinta, if any, may result in restriction, limitations and construction obligations being imposed on this real property. Print Name: �� k`- WI-t-G(.J ,-t- Title:�� (.1 • ��-. t - MC.0 [V •c Five Date: S I - I (d Phone: (5-S &) -7i S (0 Y t Building Permit Number: Project Description: SFR Exempt: ❑ (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan Plan Submittal Datel 3/9/2018 Job Site Add Owner's Nar Number, Street, or PO B City, State, Postal Co Owner's Phone Numt Owner's E-Mail Addre 51-560 Shackleton Way Lot 48B McClure, Mark 53-965 Humboldt Blvd. La Quinta, CA 92253 Project Manager's Namel Zach D. Hanan Project Manager's Phone Number 760-393-5271 Project Manager's E-mail Address Builder / Contra Number, Street or PO City, State, Postal C Project Square City Approval By Date of City Approval zhanan edi scovervbu ildersl Ic.com Discovery Builders, LLC 53-965 Humboldt Blvd. La Quinta, CA 92253 7,186 Materials To Be Discarded: Product Tons Trash 13.65 Not recyclable Asphalt 0.00 Recyclable Brick/Block 0.00 Recyclable Cardboard 2.37 Recyclable Commingled 0.00 Recyclable Concrete 0.57 Recyclable Drywall 0.42 Recyclable Donated / Reuse" 0.00 Recyclable "Describe Items Totals: Recycle Tra=]7 24.0 RECEIVED APR 3 a 2018 CITY OF LA QUINTA COMMUNITY DEVELOPMENT Product Tons Masonry (broken) 0.00 Plaster 1.44 Scrap Metal 0.00 Tile (floor) 1.22 Tile (roof) 0.00 Wood 17.97 Landscape Debris 0.00 Projected Diversion: 63.7% understand it is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, Implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 50% of the jobsite waste is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is. still issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through bi-monthly reports. if self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer Owner / Developer / Project Manager / Superintendent Date 3/16/2018 Mr Bill Harris Masonry Fireplace Industries, 6391 Jurupa Ave. Riverside, CA 92504 Dear Mr. Harris, CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE 2A 16BY MDTOW A TWINING COMPANY This is to certify that the Artisan Series -gas fired decorative appliance model ASL 120 has completed the following test criteria in compliance with the essential requirements of ANSI Z21.50/CSA 2.22-2016 standard for "Decorative Gas Appliances". Product Description: The fireplace consists of interlocking precast parts fitted together using a premixed mortar. The unit is custom made for assembling on site. The vent system consists of a 12" diameter Listed B vent duct extended vertically above the top of the unit equipped with Listed terminal hood at the top of the duct. An internal Listed draft hood is employed in conjunction with the B venting system described above. A ground mounted stainless steel burner located across the entire length of the fireplace hearth is used covered with icy mint fiberglass media. A tempered glass door is installed across the length of the front of the fireplace. Performance Testing - Natural Gas 1. Input Rate — rate received at 5" WC manifold pressure 200,000 Btu/Hr 2. Combustion — Done 3. Pilot Operating Characteristics (POC) — Done 4. Burner Operating Characteristics (BOC) — Done 5. Glass Impact test - Done 6. Water Shock test — Done 7. Temperatures (enclosure, combustible wall and floor) - Done Test and Report By Albert M. To' o Consultant Engineer, CGE. RECEIVED APR 3 0 2018 CITY OF LA UINTA COMM NI'TY DEVELOPMENT I.UPNIEN7° BUILDING ENERGY ANALYSIS REPORT I PROJECT: Custom Residence Lot 48B The Madison La Quinta, CA 92253 Project Designer: Zach Hanan Discovery Lot 48B The Madison La Quinta, CA 92253 (858) 414-0492 Report Prepared by: Jon d. Scott Scott Design and Title 24, Inc, 74818 Velie Way Suite 8 Palm Desert, CA 9 2 VTY ®F I._A s 4 0U (760) 200-4780 BUILDING & SAFETY F'PT APPR0W, FOR CONSTRUCTION Job Number: c-- DAT % BY� RECEIVED Date: SUIT p B 2018 6/1 /2018 CITY pV: LA QUINTA COMMUNITY DEVELOPMENT The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com 63 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 48B Calculation Date/Time: 13:56, Fri, Jun 01, 2018 Calculation Description: Title 24 Analysis Input File Name: tmpE44B.tmp.xml CF1 R-PRF-01 Page 1 of 13 GENERAL INFORMATION 01 Project Name Lot 48B 02 Calculation Description Title 24 Analysis 03 Project Location Lot 48B The Madison 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 20l6.3.0 (1016 SP2) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 90 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft) 7267 15 Number of Zones 4 16 Slab Area (ft2) 4983 17 Number of Stories 12 18 Addition Cond. Floor Area(ft2) n/a 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) n/a 21 Glazing Percentage (%) 136.4% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 4.70 843 -3.73 -79.4% Space Cooling 89.41 82.88 6.53 7.3% IAQ Ventilation 0.70 0.70 000 0.0% Water Heating 1.96 3.41 -1.45 -74.0% Photovoltaic Offset ---- I 0.00 0.00 ---- Compliance Energy Total 96.77 95.42 1.35 1.4% Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-01 13:57:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 48B Calculation Date/Time: 13:56, Fri, Jun 01, 2018 Calculation Description: Title 24 Analysis Input File Name: tmpE4413.tmp.xmI C F1 R-PR F-01 Page 2 of 13 ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR 46.6 46.0 0.0 46.0 ❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreenA4.203.1.2.1) and QII verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. ❑ Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified. Notes: • Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering tNEMj rules REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Window overhangs and/or fins HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High quality insulation installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: • Pipe Insulation, All Lines Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-01 13:57:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Lot 48B Calculation Date/Time: 13:56, Fri, Jun 01, 2018 Page 3 of 13 Calculation Description: Title 24 Analysis Input File Name: tmpE44B.tmp.xml BUILDING - FEATURES INFORMATION 01 02 03 04 05 I 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Lot 48B 7267 1 4 I 4 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Floor Area Avg. Ceiling Zone Name Zone Type HVAC System Name (ft2) Height Water Heating System 1 Water Heating System 2 master Conditioned HVACmstrl 9 DHW Sys 1 n/a stairs Conditioned HVACstair2 1 542 9 DHW Sys 1 n/a main level Conditioned HVAC grt3 2695 9 DHW Sys 1 n/a 2nd level Conditioned HVAC 2nd4 2284 9 ! DHW Sys 1 n/a Registration Number: Registration DateMme: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-01 13:57:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 48B Calculation Date/Time: 13:56, Fri, Jun 01, 2018 Calculation Description: Title 24 Analysis Input File Name: tmpE44B.tmp.xml C F1 R-PRF-01 Page 4 of 13 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) N Wall master R-21 Wall 0 Right 1029 119.5 90 E Wall master R-21 Wall 90 Front 566 68.3 90 S Wall master R-21 Wall 180 Left 588 59.9 90 W Wall master R-21 Wall 170 - specify - 566 213.8 90 Interior Surface master»stairs R-13 Wall n/a n/a 200 0 n/a Roof 3 master R-38 Roof AtticR19 n/a n/a 1746 n/a n/a N Wall 2 stairs R-21 Wall 0 Right 388 360 90 E Wall 2 stairs R-21 Wall 90 Front 388 114 90 S Wall 2 stairs R-21 Wall 180 Left 588 139.4 90 W Wall 2 stairs R-21 Wall 170 - specify - 566 43 90 Interior Surface 2 I stairs»main level R-13 Wall n/a n/a 200 0 n/a Roofstr stairs R-38 Roof AtticR19 n/a n/a 542 n/a n/a N Wall 3 main level R-21 Wall 0 Right 1101 162.8 90 E Wall 3 main level R-21 Wall 90 Front 986 220.8 90 S Wall 3 main level R-21 Wall 180 Left 288 216 90 W Wall 3 main level R-21 Wall 170 - specify - 986 344.4 90 Interior Surface 3 main level»2nd level R-13 Wall n/a n/a 200 0 n/a Roof 4 main level R-38 Roof AtticR19 n/a n/a 2656.8 n/a n/a N Wall 4 2nd level R-21 Wall 0 Right 832 151.9 90 E Wall 4 2nd level R-21 Wall 90 Front 788 34.5 90 S Wall 4 2nd level R-21 Wall 180 Left 832 197.6 90 W Wall 4 2nd level R-21 Wall 270 Back 788 261,921 90 Interior Surface 4 2nd level»master R-13 Wall n/a n/a 200 0 n/a Roof 5 2nd level coolR-38 Roof AtticR19 n/a n/a 22777 n/a n/a Registration Number: Registration DateTl-ime: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-01 13:57:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot48B Calculation DatelTime: 13:56, Fri, Jun 01, 2018 Calculation Description: Title 24 Analysis Input File Name: tmpE44B.tmp.xml CF1 R-PRF-01 Page 5 of 13 OPAQUE SURFACES — Cathedral Ceilings 01 02 03 04 05 06 07 08 09 10 11 Name Zone Type Orientatio n Area (ft2) Skylight Area (ft2) Roof Rise (x in 12) Roof Pitch Roof Tilt (deg) Roof Reflectance Roof Emittance Framing Factor Roof main level R-38 Roof AtticR191 I Right 38.3 382 3 0.25 14.04 0.65 0.91 0.1 Roof 2 2nd level coolR-38 Roof AtticR191 Right I 6.4 1 1 3 0.25 1 14.04 0.65 0.91 0.1 ATTIC 01 02 I 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic master Attic Roofmaster Unventilated 3 0.65 0.91 Yes Yes Attic stairs Attic Roofstairs Unventilated 3 065 0.91 Yes Yes Attic main level Attic Roofmain level Unventilated 3 I 065 0.91 Yes Yes Attic 2nd level Attic Roof2nd level Unventilated 3 0.65 0.91 Yes Yes Registration Number: Registration Date/T-ime: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-01 13:57:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 48B Calculation Description: Title 24 Analysis Calculation Date/Time: 13:56, Fri, Jun 01, 2018 Input File Name: tmpE44B.tmp.xml CF1 R-PRF-01 Page 6 of 13 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft2) U-factor SHGC Exterior Shading 3w Window N Wall (Right-0) - 1 34.0 0.48 0.23 Insect Screen (default) 7w Window N Wall (Right-0) 1 33.0 0.48 0.23 Insect Screen (default) 5d Window N Wall (Right-0) -- 1 52.5 0.39 0.23 Insect Screen (default) 6d Window E Wall (Front-90) - -- 1 68.3 0.48 0.23 Insect Screen (default) 4d Window S Wall (Left-180) 1 59.9 0.48 0.23 Insect Screen (default) 4d 2 Window W Wall (- specify --170) - 1 183.8 0.48 0.23 Insect Screen (default) 6w Window W Wall (- specify --170) 1 30.0 0.48 0.23 Insect Screen (default) 51w Window N Wall 2 (Right-0) - -- 1 360.0 0.48 0.23 Insect Screen (default) 52w Window E Wall 2 (Front-90) - 1 90.0 0.48 0.23 Insect Screen (default) 4W Window S Wall 2 (Left-180) -- - - 1 15.6 0.48 0.23 Insect Screen (default) 53w Window S Wall 2 (Left-180) -- 1 90.0 0.48 0.23 Insect Screen (default) 5w Window S Wall 2 (Left-180) - 1 33.8 0.48 0.23 Insect Screen (default) 2w Window W Wall 2 (- specify - 170) - - - 1 43.0 0.48 0.23 Insect Screen (default) 57w Window N Wall 3 (Right-0) --- -- 1 162.8 1 0.48 0.23 Insect Screen (default) 2d Window E Wall 3 (Front-90) 8.0 12.0 1 96.0 0.39 0.23 Insect Screen (default) 1 W Window E Wall 3 (Front-90) ---- ---- 1 42.0 0.48 0.23 Insect Screen (default) 54w Window S Wall 3 (Left-180) - --- 1 72.0 0.39 0-23 Insect Screen (default) 55w Window S Wall 3 (Left-180) - 1 72.0 0.39 023 Insect Screen (default) 56w Window S Wall 3 (Left-180) - - 1 72.0 0.39 0.23 Insect Screen (default) 3d Window W Wall 3 (- specify --170) 28.7 12.0 1 344.4 0.39 0.23 Insect Screen (default) Skylight22 Skylight Roof (Right-0) 1 13.3 0.39 0.25 Skylight21 Skylight Roof (Right-0) 1 24.9 0.39 0.25 9w Window N Wall 4 (Right-0) -- 1 29.2 0.39 0.23 Insect Screen (default) 8w Window N Wall 4 (Right-0) ---- - 1 14.5 0.48 0.23 Insect Screen (default) 58w Window' N Wall 4 (Right-0) -- - - 1 72.0 0.48 0.23 Insect Screen (default) 11w Window N Wall 4 (Right-0) -- 1 19.3 0.48 0.23 Insect Screen (default) 12W Window N Wall 4 (Right-0) - --- 1 16.9 0.48 0.23 Insect Screen (default) 13W Window E Wall 4 (Front-90) ---- -- 1 34.5 0.48 023 Insect Screen (default) 59w Window S Wall 4 (Left-180) -- 1 54.6 0.48 L 023 Insect Screen (default) Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-01 13:57:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot48B Calculation Date/Time: 13:56, Fri, Jun 01, 2018 Calculation Description: Title 24 Analysis Input File Name: tmpE44B.tmp.xml CF1 R-PRF-01 Page 7 of 13 60w Window S Wall 4 (Left-180) -- 1 54.6 0.48 0.23 Insect Screen (default) 61w Window S Wall 4 (Left-180) ---- 1 54.6 0.48 0.23 Insect Screen (default) 10w Window S Wall 4 (Left-180) ---- -- 1 33.8 0.48 0.23 Insect Screen (default) 7ad Window W Wall 4 (Back-270) 165 9.1 1.005 150.9 0.39 0.23 Insect Screen (default) 7bd Window W Wall 4 (Back-270) 12.2 9.1 1 111.0 0.39 0.23 Insect Screen (default) Skylight20 Skylight Roof 2 (Right-0) 1 6.3 0.39 0.25 OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor 8d garage E Wall 2 24.0 0.50 1 D E Wall 3 82.8 0.50 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up I Dist L Bot Up Depth Top Up Dist R Bot Up 2d 6 0.1 6 0 0 0 0 0 0 0 0 0 3d 18 0.1 18 18 0 0 0 0 0 0 0 0 0 7ad 18 0.1 18 18 0 0 0 0 0 0 0 0 0 7bd 18 0.1 18 18 0 0 0 0 0 0 0 0 0 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-01 13:57:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Lot 48B Calculation Description: Title 24 Analysis Calculation Date/Time: 13:56, Fri, Jun 01, 2018 Input File Name: tmpE44B.tmp.xml Page 8 of 13 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers • Around Roof Joists: R-6.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofmaster Attic Roofs Wood Framed Ceiling in. O.C- R 19 0.059 Roofing: Light Roof (Asphalt Shingle) Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof AtticR19 attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Ceiling Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R-21 /2x6 R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.069 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board • Cavity/Frame: R-13/2x4 R-13 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.092 Other Side Finish: Gypsum Board • Around Roof Joists: R-6.0 insul. • Cavity / Frame: R-13.0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofstairs Attic Roofs Wood Framed Ceiling in O.C. R 19 0.059 Roofing: Light Roof (Asphalt Shingle) • Around Roof Joists: R-6.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck Wood Siding/sheathing/decking Attic Roofmain level Attic Roofs Wood Framed Ceiling in. O.C. R 19 0.059 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Sheathing / Insulation: R19 Sheathing • Cavity / Frame: R-38 / 2x4 • Roof Deck: Wood Siding/sheathing/decking R-38 Roof AtticR191 Cathedral Ceilings Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.019 Roofing: Light Roof (Asphalt Shingle) • Around Roof Joists: R-6.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roof2nd level Attic Roofs Wood Framed Ceiling in. O.C. R 19 0.059 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 coolR-38 Roof AtticR19 attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Ceiling Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Sheathing / Insulation: R19 Sheathing • Cavity / Frame: R-38 / 2x4 • Roof Deck: Wood Siding/sheathing/decking coolR-38 Roof AtticR191 Cathedral Ceilings Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.019 Roofing: Light Roof (Asphalt Shingle) Registration Number: Registration DateMme: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-01 13:57:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 48B Calculation Date/Time: 13:56, Fri, Jun 01, 2018 Calculation Description: Title 24 Analysis Input File Name: tmpE44B.tmp.xml CF1 R-PRF-01 Page 9 of 13 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Slab -on -Grade master 1746 212 None 0.8 No Slab -on -Grade 2 stairs 542 212 None 0.8 No Slab -on -Grade 3 main level 2695 212 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW (HERS req'd) Pipe Insulation, All Lines DHW Heater 1 (2) 2 .0% WATER HEATERS 01 02 03 04 05 06 07 I 08 09 10 11 12 Name Heater Element Type Tank Type Number of Units Tank Volume (gall Uniform Energy Factor / Energy Factor / Efficiency Input Rating / Pilot / Thermal Efficiency Tank Insulation R-value (Int/Ext) Standby Loss / Recovery Eff First Hour Rating / Flow Rate NEEA Heat Pump Brand / Model / Other Tank Location or Ambient Condition DHW Heater 1 Gas Small Storage 2 75 0.68 EF 65,000 Btu/hr R-0/R-0 n/a n/a T n/a n/a WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/2 Pipe Insulation, All Lines n/a n/a n/a I n/a n/a Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-01 13:57:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 48B Calculation Date/Time: 13:56, Fri, Jun 01, 2018 Calculation Description: Title 24 Analysis Input File Name: tmpE44B.tmp.xml CF1 R-PRF-01 Page 10 of 13 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVACmstr1 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVACstair2 Other Heating and Cooling System Heating Component 2 , ,Cooling Component 2 HVAC Fan 2 Air Distribution System 2 HVAC grt3 Other Heating and Cooling System Heating Component 3 Cooling Component 3 HVAC Fan 3 Air Distribution System 3 HVAC 2nd4 Other Heating and Cooling System Heating Component 4 Cooling Component 4 HVAC Fan 4 I Air Distribution System 4 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Efficiency Heating Component 1 CntrlFurnace I 1 80 AFUE Heating Component 2 CntrlFurnace 1 80 AFUE Heating Component 3 CntrlFurnace 2 80 AFUE Heating Component 4 CntrlFurnace 1 80 AFUE HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Efficiency Name System Type Number of Units EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 SplitAirCond 1 12.7 16 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component 2 SplitAirCond 1 13 16 Not Zonal Single Speed Cooling Component 2-hers-cool Cooling Component 3 SplitAirCond 2 12.7 16 Not Zonal Single Speed Cooling Component 3-hers-cool Cooling Component 4 SplitAirCond 1 12.7 16 Not Zonal Single Speed Cooling Component 4-hers-cool Registration Number: Registration DateRme: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-01 13:57:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 48B Calculation Date/Time: 13:56, Fri, Jun 01, 2018 Calculation Description: Title 24 Analysis Input File Name: tmpE44B.tmp.xml CF1 R-PRF-01 Page 11 of 13 HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Required Required Cooling Component 2-hers-cool Required 350 Required Required Required Cooling Component 3-hers-cool Required 350 Required Required Required Cooling Component 4-hers-cool Required 350 Required Required Not Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Specified Lower Leakage Target 8 Attic None Air Distribution System 1-hers-dist Air Distribution System 2 DuctsAttic Specified Lower Leakage Target 8 Attic None Air Distribution System 2-hers-dist Air Distribution System 3 DuctsAttic Specified Lower Leakage Target 8 Attic None Air Distribution System 3-hers-dist Air Distribution System 4 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 4-hers-d ist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required Air Distribution System 2-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required Air Distribution System 3-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required Air Distribution System 4-hers-dist Required 5.0 Not Required Not Required Not Required Not Required n/a Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-01 13:57:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 48B Calculation Date/Time: 13:56, Fri, Jun 01, 2018 Calculation Description: Title 24 Analysis Input File Name: tmpE44B.tmp.xml CF1 R-PRF-01 Page 12 of 13 HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.54 HVAC Fan 1-hers-fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.54 HVAC Fan 2-hers-fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.54 HVAC Fan 3-hers-fan HVAC Fan 4 Single Speed PSC Furnace Fan 0.58 HVAC Fan 4-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.54 HVAC Fan 2-hers-fan Required 0.54 HVAC Fan 3-hers-fan Required 0.54 HVAC Fan 4-hers-fan Required I 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 110 0.25 Default I 0 Required Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-01 13:57:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 48B Calculation Date/Time: 13:56, Fri, Jun 01, 2018 Calculation Description: Title 24 Analysis Input File Name: tmpE44B.tmp.xml C F1 R-PRF-01 Page 13 of 13 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name Documentation Author Signature: Jon d. Scott Company: Signature Date: Scott Design and Title 24, inc, 5/1/2018 Address: 74818 Veiie Wad Suite 8 CEA/HERS %ertification Identification (If applicable): City/Stat p: �Im Bert, 92269 Phone: ��� 291 -4789 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Zach Hanarl Responsible Designer Signature: Company- Zach Hanan Discovery Date Signed: Address: Lot 48B The Madison License: City/StatefZip: La Quinta, CA 92258 Phone: (858) 414-9492 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-01 13:57:48 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Custom Residence Project Address Lot 48B The Madison La Quinta Building Type m Single Family ❑ Addition Alone f ❑ Multi Family ❑ Existing+ Addition/Alteration California Energy Climate Zone Total Cond. Floor Area Addition CA Climate Zone 15 7,267 n/a Date 61112018 - # of Units 1 INSULATION Construction Tye Cavity Area (ft) Special Features Status Roof Wood Framed Attic R 38 4,945 Add=R-19.0 Cool Roof New Wall Wood Framed Slab Unheated Slab -on -Grade Demising Wood Framed R 21 - no insulation R 13 8,572 4,983 Perim = 636' 800 New New New Door Opaque Door - no insulation 107 New Roof Wood Framed Attic R 38 2,278 Add=R-19.0 Cool Roof New FENESTRATION Orientation Area ft2 I Total Area: 2.646 Glazin Percentage: 36.4/ New/Altered Average U-Factor. U-Fac SHGC Overhang Sidefins Exterior Shades 0.44 Status Right (N) 712.5 0.480 0.23 none none Bug Screen New Right (N) 81.7 0.390 0.23 none none Bug Screen New Front (E) 234.8 0.480 0.23 none none Bug Screen New Left (S) 396.9 0.480 0.23 none none Bug Screen New Left (S) 256.8 0.480 0.23 none none Bug Screen New Skylight 13.3 0.390 0.25 none none None New Skylight 24.9 0.390 0.25 none none None New Front (E) 96.0 0.390 0.23 6.0 none Bug Screen New Left (S) 216.0 0.390 0.23 none none Bug Screen New Left (S) 344.4 0.390 0.23 18.0 none Bug Screen New Skylight 6.3 0.390 0.25 none none None New Rear(lM 261.9 0.390 a23 18.0 none Bug Screen New HVAC SYSTEMS Qt . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE 1 Central Furnace 80% AFUE 2 Central Furnace 80% AFUE HVAC DISTRIBUTION Location Heating Split Air Conditioner 16. 0 SEER Setback Split Air Conditioner 16.0 SEER Setback Split Air Conditioner 16.0 SEER Setback Duct Cooling Duct Location R-Value New New New Status HVACmstr Ducted HVACstair Ducted HVAC gr1 Ducted WATER HEATING Qty. Type Ducted Attic 8.0 Ducted Attic 8.0 Ducted Attic 8.0 Gallons Min. Eff Distribution New New New Status 2 Small Storage Gas 75 0.68 All Pipes Ins (HERS) New Eneie Pro 7.2 by EnergySoft User Number: 6712 ID: Page 16 of 42 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Custom Residence Project Address Lot 48B The Madison La Quinta Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration California Energy Climate Zone Total Cond. Floor Area Addition CA Climate Zone 15 7, 267 n/a Date 61112018 # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status FENESTRATION Total Area: Z646 Glazing Percentage: 36.4% 1 New/Altered Average U-Factor. Orientation Area ff U-Fac SHGC Overhang Sidefins Exterior Shades 0.44 Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE HVAC DISTRIBUTION Location Heating Split Air Conditioner 16 0 SEER Setback Duct Cooling Duct Location R-Value New Status HVAC 2nd Ducted Ducted Attic 8.0 WATER HEATING Qty. Type Gallons Min. Eff Distribution New Status EnerqyPro 7.2 by EnerqySoft User Number.' 6712 ID: R! e 17 of 42 2016 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. "Exceptions may apply. fOrioinal 08/20191 Building Envelope Measures: § 110.6(a)1: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft' or less when tested per NFRC-400 orASTM E283 orAAMA/WDMA/CSA 101/I.S.2/A440-2011.' § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES 110.E-A and 110.E-B for cam fiance and must be caulked andlor weatherstri ed.' § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 110.8 € when the installation of a cool roof is specified on the CF1 R. § 110.8(j): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average 1-1-factor must not exceed 0.043. Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on to2 of a drywall ceiling.' § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-factor of 0.074 or § 150.0(c): less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly.* § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor; § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration; and, when installed as art of a heated slab floor, meet the requirements of § 110.$ . § 150.0(g)l: Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to J 150.0(d). § 150.0(g)2: Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all insulation in all exterior walls, vented attics and unvented attics with air -permeable Insulation. 150.0 § (q)' Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-factor of 0.58; or the weighted averse U-factor of all fenestration must not exceed 0.58." Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)lA: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)l B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is OuIpped with a readily accessible, ❑ erable, and tight -fitting damper or combustion -air control device." § 150.0(e)l C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0-§ 110.3: Certification. Healing, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appIiances must be certified b the manufacturer to the Energy Commission.' § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating.' § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat.' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 11 0.3c . § 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushin2 when the valves are closed. § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- ances without an electrical supply voltage connection with Ilot lights that consume less than 150 Btu/hr are exem t); and pool and spa heaters' Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)l: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J using design conditions s cified in § 150.0(h)2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any d er vent. § 150.0(h)3B: Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's instructions. 150.0 § U)1 ' Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures' § 1500(j)2B: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve.' § 150.0(j)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution i in for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind, Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.0(j)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the material. § 150.0(j)3B: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class II vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)l: 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr, § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar Water -heating Systems. Solar water- heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation SRCC or by a lisling agency that is approved by the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CIVIC). If a contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CIVIC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CIVIC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)l: (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than''/< inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts: Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such.tape is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustion iniet and outlet airopenings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)l l : occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0 m 11 and Reference Residential A endix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure drop, and labeling requirements of § 1 50.0m 12. 2016 Low -Rise Residential Mandatory Measures Summary Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (;PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RAU. This applies to both single zone central forced air systems and every zone for zonally controlled central forced airs stems.' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(o): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing whole -building ventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.' § 110.4(b)1: Pip!ng. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heatino. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only dude Off-peak electric demand p0bds. § 110,5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. 150.0 Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow § (p)' rater piping, filters, and valves.' Lighting Measures: § 110.9.. Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9.' § 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must be certified to the Energy Commission aocordig to Reference Joint Aependix JAB. § 150.0(k)1A: Luminatre Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan speed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1 C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection in all recessed downl' ht luminaires in oeilin s. § 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods § 150.0(k)1 F: must meet the applicable requirements of § 150.0(k); ) Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1 G: with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016' or "JA8-2016-E" as specified in Reference Joint Appendix § 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E." § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.Ofkl. § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4, meets the EMCS requirements of § 130.5 ; and meets all other requirements in § 150.0(k)2. Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5 ; and all other requirernenls in,§ 150.0(k)2. § 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it Provides the functionality of a dimmer accordin to § 110.9 and complies with all other applicable requirements in §i 150,0fki2. 0 2016 Low -Rise Residential Mandatory Measures Summary § 150 0(k)2J: hrterior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancy sensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.* § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMCS. Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either 150.4 k 3A or with the applicable requirements in 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0 k 3B or§ 150.0 k 3D must comply with the a2plicable requirements in 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of power as determined according to § 130.0(c). § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in §§ 110.9. 130.0,130.1 130.4 140.6, and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150,0(k)6B: i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of in ress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110,10(a)1: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the requirements of § 110.10(b) through § 110.10 e . § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1: greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.' § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110,10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment.* Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical lane.' § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof five load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through 11 0.10c must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location. and permanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Custom Residence 6/1/2018 System Name Floor Area HVACmstr 1,746 ENGINEERING CHECKS SYSTEM LOAD Number of S stems 1 COIL CFM Total Room Loads 1,381 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. Sensible Latent CFM 28,469 2,366 790 0 1,341 0 0 0 0 1,489 1,341 32,640 2,366 PEAK Heating System Sensible Output perSystem 89,000 28,980 Total Output Btuh 89,000 Output Btuh/s ft 51.0 1,106 Coolin2 System 0 Output per System 57,500 0 Total Output Btuh 57,500 -1,489 Total Output (Tons) 4•8 1,106 Total Out ut Btuh/sgft) 32-9 Total Output s ft/Ton 364.4 29,704 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow (cfm) 2,000 24ACP760/58PH**l 10 432776 43,776 5,087 5,087 89,000 89,000 Jan 1 AM Airflow (cfm/s ft) 1.15 Airflow (cfm/Ton) 417.4 Outside Air %) 0•0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Outside Air (cfm/sgft) 0.00 Note: values above given at A conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak 26 °F 70 °F 105 °F 105 OF Outside Air 0 cfm Heating Coil Supply Fan 2,000 cfm 104 OF ROOM 69 °F 70 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak) 112/78OF 76/62°F 55/54°F 55/54°F Outside Air 0 cfm Cooling Coil Supply Fan 56 / 54 OF 2,000 cfm 47.3% + ROAM 75 / 62 OF I1fl EnergyPro 7.2 by Energy5oft User Number: 6712 ID: Pape 22 of 42 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Custom Residence System Name HVACstair Date 6/1 /2018 Floor Area 1 549 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,121 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 71,000 23,246 734 716 26,326 Total Output Btuh) 71,000 0 Output Btuh/s ft 131.0 1,095 1,005 Cooling System 0 0 Output per System 23,500 0 0 0 0 Total Output (Btuh 23,500 1,489 734 -1.489 Total Output(Tons).2•0 1,095 1,005 Total Output (Btuh/sgft) 43.4 Total Output (sgft/Ton) 276.8 26,925 26,847 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ACP724/58PH""045 or = 2 13,776 13,776 6.092 6,092 71,000 71,000 Jan 1 AM Airflow (cfm/s ft) 3.69 Airflow (cfm/Ton) 1,021.3 Outside Air (%) 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Outside Air cfmfs ft) 0.00 Aug 3 PM Note: values above given at ARI conditions I HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF 105 OF 105 OF ❑ Ok Outside Air 0 cfm Heating Coil Fa n an Supply105 2,000 cfm OF ROOM 70 °F COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112 / 78 OF 76 / 62 °F 55 / 54 °F 55 / 54 OF Outside Air a I 0 cfm Cooling Coil Supply Fan 56 / 54 OF 2,000 cfm 46.3% � M ROO 76 / 62 °F= 75 161 OF Ener'gyPro 7.2 by EnergySoft User Number.- 6712 ID: FWW 23 of 42 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Custom Residence Date 6/1/2018 Floor Area 2,695 System Name HVAC grt ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 2,252 Return Vented Lighting Return Air Ducts Return Fan Ventilation [ 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. Sensible Latent CFM 46,691 3,651 1.111 0 2,200 0 0 0 0 2,978 2,200 F 54,069 3,651 PEAK Heating System Sensible Output per System 89,000 40,963 Total Output (Btuh) 178,000 Output Btuh/s ft 66.0 1,564 CoolinR System 0 Output per System 57,500 0 Total Output Btuh 115,000 -2,978 Total Output (Tons) 9.6 1,564 Total Output (Btuh/s ft) 42.7 Total Output s ft/Ton 281.2 41,112 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 4,000 24ACP760/58PH**l10 87,626 9.902 178,000 178,000 Jan 1 AM Airflow cfm/s ft) 1.48 Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Airflow (cfm/Ton) 417.4 Outside Air (%) 0.0% 87,626 9,902 Outside Air cfm/sgft) 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 26 °F 70 OF 105 OF 105 OF Outside Air i 0 cfm Heating Coil Supply Fan 4,000 cfm 105 F ROOM 70 "F COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak 112 178 OF 76 / 62 OF 55 / 54 °F 5 / 54 OF Outside Air 0 cfm Cooling Coil Supply Fan 4,000 cfm 76 / 62 °F H U 56 / 54 OF E ROOM 47.0% j 75 / 62 OF .._ EnergyPro 7.2 by EnergySoft User Number.- 6712 ID: Page 24 of 42 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date _Custom Residence 6/1/2018 System Name Floor Area HVAC 2nd 2,284 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent CFM Sensible Output perSystem 89,000 Total Room Loads 1,427 29,382 3,094 760 27,907 Total Output Btuh 89,000 Return Vented Lighting Return Air Ducts 0 1,3841 1,065 Output Btuh/s ft 39•0 Cooling System Return Fan Ventilation 0 Supply Fan Supply Air Ducts 0 0 0 0 0 0 1,489 -1,489 1,384 1,065 Output per System 57,500 Total Output Btuh 57,500 Total Output (Tons) 4•8 Total Output (Btuh/s ft) 25.2 TOTAL SYSTEM LOAD 33,639 3,094 28,549 Total Output s ft/Ton 476.7 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow (cfm) 2,000 24ACP760/58PH"'110 43,545 5.424 89,000 Airflow cfmis ft) 0.88 43.545 5.424 89,000 Jan 1 AM Airflow (cfm/Ton) 417.4 Outside Air [o/a) 0.0°/o Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Outside Air (cf n1s ft) 0.00 Note: values above eiven at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 °F 105 OF 105 °F 0 � Outside Air I 0 cfm Heating Coil Supply Fan 2,000 cfm 104 OF ROOM 69 °F 70 °F 14 COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78OF 76/62°F 55/54°F 5.5/54OF Outside Air ■ i 0 cfm Cooling Coil Supply Fan 56 / 54 OF 2,000 cfm 47.8% � �©�� 76/62°F 75/62OF EnergyPro 7.2 by EnergySoft User Number. 6712 ID: Page 25 of 42 ZONE LOAD SUMMARY Project Name Custom Residence Date 61112018 System Name HVACmstr J Roof Area II 1,746 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM I Sensible Latent CFM Sensible master 1.0 0 Aug 3 PM 1,381 28,469 2,366 790 28,980 TOTALS 0 0 0 0 Aug 3 PM 28,469 2,366 28,980 (BLOCK LOAD) EnergyPro 72 by Energy5oft User Number: 6712 ID page 26 of 42 ZONE LOAD SUMMARY Project Name Date Custom Residence 6/1/2018 System Name HVACstair Floor Area 542 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible stairs 1.0 0 Aug 3 PM 1,121 23,246 734 716 26,326 I TOTALS 0 0 0 0 Aug 3 PM 23,246 1 734 26,326 (BLOCK LOAD) EnergyPro 7.2 by EnergySoR User Number. 6712 fA: Page 27 of 42 ZONE LOAD SUMMARY Project Name Date Custom Residence 61112018 System Name Floor Area HVAC grt 2,695 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible main level 1.0 0 Aug 3 PM 2,252 46,691 3,651 1,111 40,963 I iI I TOTALS 0 01 01 0 Aug 3 PM 46, 691 3, 651 ! 40,963 (BLOCK LOAD) EnergyPro 7.2 by EnergySoff user Number: 6772 ID: Page 28 of 42 ZONE LOAD SUMMARY Project Name Custom Residence Date 6/1/2018 System Name HVAC 2nd Floor Area 2,284 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME J SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM I Sensible 2nd level 1.0 0 Aug 3 PM 1,427 29,382 3,094 760 27,907 I TOTALS 0 0 0 0 Aug 3 PM 29,382 3,094 27,907 (BLOCK LOAD) EnergyPro 7.2 by Energy5afi User Number., 6712 )D: Page 29 Cf 42 ROOM LOAD SUMMARY Project Name Custom Residence System Name HVACmstr ROOM LOAD SUMMARY Date 61112018 Floor Area 1,746 ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name I Room Name Mult. CFM Sensible I Latent CFM I Sensible Latent CFM I Sensible master I Master bedroom 1 1 1,381 28,4691 2,3661 1,3811 28,4691 2,366 7901 28,960 PAGE TOTAL TOTAL" 1,381 28,469 2,366 790 28;980 1,381 26,4691 2,3661 7901 28,980 " Total includes ventilation load for zonal s stems. Energyero 7.2 P1 Ener Soft User Number. 6712 ID: Page 30 of 42 ROOM LOAD SUMMARY Project Name Custom Residence Date ! 61112018 Floor Area 542 System Name HVACstair ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM I Sensible Latent CFM Sensible stairs Stair Well 1 1,121 23,246 734 1,121 23,246 734 716 26,326 PAGE TOTAL 1,121 23,246 734 7i6 26,326 TOTAL ` 1,121 23,246 734 716 2fi,328 ' Total includes ventilation load for zonal systems. Enea7LPro 7.2 by EnergySoft User Number: 6712 ID: Pace 31 of 42 ROOM LOAD SUMMARY Project Name Custom Residence Date 6/1/2018 Floor Area 2,695 System Name HVAC glf ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible main level Main level Lot 488 1 2,252 46,691 3,651 2,252 46,691 3,651 12111 40,963 PAGE TOTAL 2,252 46,691 3,651 1,111 40,963 TOTAL" Z252 46,591 3,6511,111 40,963 Total includes ventilation load for zonal systems. Ener Pro 7.2 by FnergySoft User Number: 6712 ID: Page 32 of 42 ROOM LOAD SUMMARY Project Name Date Custom Residence 6/1/2018 System Name Floor Area HVAC 2nd 2,284 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. I CFM I Sensible LatentP1,4271 FM Sensible Latent CFM Sensible 2nd level second level Lot 48B 1 1,427 29,382 3,09429,3821 3,094 7601 27,907 PAGE TOTAL TOTAL " 1,427 29,382 3,0941 760 27,907 1,427 29,382 3,094 7601 27,907 Total includes ventilation load for zonal systems. EnergyPro 7.2 by EnergySoft User Number. 6712 ID: Pa e 33 of 42 ROOM HEATING PEAK LOADS Project Name Custom Residence Date 6/1/2018 ROOM INFORMATION DESIGN CONDITIONS Room Name Master bedroom Floor Area 1,746.00 ftz Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area _ 1,746.0 X X X X X X X X, X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 3551 { AT °F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 441 Btu/hr R-36 RoofA(UcR19 0.0174 44 1,337 R-21 Wall 2,287.5 0.0690 44 6,945 Window.48.23 30001 409.0 0.4800 44 8,638 Window.39.23 3000f 52.5 0.3900 44 901 Slab -On -Grade perim = 212.0 a7300 44 6,809 'R-13 Wag 200.0 0.1020 0 0 another room 9.00 X Height AC Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1, 746 X Area Page Total / 60 X' AT 24,630 TOTAL HOURLY HEAT LOSS FOR ROOM 28,980 EnergyPro 7.2 by EnergySoft User Number: 6712 ID: Page 34 of 42 ROOM HEATING PEAK LOADS Project Name Custom Residence Date 6/1/2018 ROOM INFORMATION DESIGN CONDITIONS Room Name Stair Well Floor Area 542.00 ftz Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Celiing U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F = = = = = c = = = = = = = = = = = = = = = = = = = = = = = = 44 Btu/hr R-38 RoofAtlicR19 542.0 0.0174 44 415 R-21 Wall 1,273.6 0.0690 44 3,867 Window.48-23 3000f 632.4 0.4800 44 13,356 Wood Door 24.0 0.5000 44 528 Slay -Ors -Grade perim = 212.0 0.7300 44 6,809 'R-13 Wall 200.0 0.1020 0 0 Items shown with an asterisk (") denote conduction Infiltration:[ 1.Q0 X 1.064 Schedule Air Sensible Fraction through an interior surface X 542 X Area another room 9.00 X 0.355 Height ACH Page Total / 60 ] X AT 24,975 = 1,35Q TOTAL HOURLY HEAT LOSS FOR ROOM 26,326 EnergyPro 7-2 by EnergySoft User Number-- 6712 1D: Page 35 of 42 ROOM HEATING PEAK LOADS Project Name Custom Residence Date 61112018 ROOM INFORMATION DESIGN CONDITIONS Room Name Main level Lot 48B Floor Area 2,695.00 ft2 Indoor Dry Bulb Temperature 70 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area 2,656.8 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 44 Btu/hr R-38 Roof A tticR 19 0.0174 44 2,034 Skylight .39.25 38.2 0.3900 44 656 R-21 Wall 2,417.0 0.0690 44 7,338 Window.48.23 3000f 204.8 0.4800 44 4,325 Window.39.23 3000f 656.4 0.3900 44 11,264 Wood Door 82.8 0.5000 44 1,822 Slab -On -Grade perim = 212.0 0.7300 44 6,809 "R-13 Wall 200.0 0.1020 0 0 through an interior surface X F 2,695 X Area Items shown with an asterisk (") denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction another room 9.00 X 0.355] Height ACH Page Total / 60 ] X AT 34,248 6,714 TOTAL HOURLY HEAT LOSS FOR ROOM 40,963 EnergyPro 7.2 by EnergySoft User Number. 6712 ID: Page 36 of 42 ROOM HEATING PEAK LOADS Project Name Date Custom Residence 61112018 ROOM INFORMATION DESIGN CONDITIONS Room Name second level Lot 48B Floor Area 2,284.00 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area coofR-38 Roof AttrcR19 2,277.7 X Skylrghf .39.25 6.3 X R-21 }Nall 2,594.1 X Window 39.23 3000f 291.1 X Window.48,23 3000f 354.8 X 'R-13 watt 200.0 X X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction through an interior surface to Infiltration:[ 1.00 X 1.064 X 2,284 X Schedule Afr Sensible Area Csilfng Fraction U_-Value 0.0174 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F = 0 = = _ = = = = = = = = = = = = = = = = = = = = = = = = = 44 Btu/hr 44 44 1,744 0.3900 108 0.0690 44 7,876 0.3900 44 4,995 0.4800 44 7,493 0.1020 0 0 Page Total / 60 X AT another room 9.00 X 0.355 Height ACH 22.217 5,690 TOTAL HOURLY HEAT LOSS FOR ROOM 27,907 EnargyPro 7.2 by EnergySoft User Number.- 6712 ID: Page 37 of 42 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 61112018 ROOM INFORMATION DESIGN CONDITIONS Room Name Master bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 1,746.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 0F1 Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 Roo[AtfrcR19 (N) 1,746.0 X 0.0174 X 77.0 = 2,340 R-21 Wall (N) 909.5 X 0.0690 X 31.0 = 1,945 R-21 Wall (E) 497.7 X 0.0690 X 44.0 = 1,511 R-21 Wall (S) 528.1 X 0.0690 X 38.0 = 1,385 R-21 Wat! (S) 352.2 X 0.0690 X 39.1 = 950 IR-13 well 200.0 X 0.1020 X 0.0 = 0 X X = X X = X X = Page Total 8,131 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 3W (N) 0.0 X 21.0 + 34.0 X 21.0 = 713 7w (N) 0.0 X 21.0 + 33.0 X 21.0 = 692 5d (N) 0.0 X 19.2 + 52.5 X 19.2 = 1,007 6d (E) 0.0 X 21.0 + 68.3 X 41.5 = 2,832 4d (S) 0.0 X 21.0 + 59.9 X 26.0 = 1,560 4d (S) 0.0 X 21.0 + 183.8 X 27.4 = 5.038 6w (S) 0.0 X 21.0 + 30.0 X 27.4 = 822 X + X = X + X = Page Total 12,665 Internal Gain Btulhr Occupants 5.2 Occupants X 245 Btuh/occ. - 1,285 1,746 FloorArea X 0.50 g 2Equipment ,980 Infiltration: 1.064 X 1.20 X 72.01 X 37 = 3,409 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 28,469 Latent Gain Btulhr Occupants 5 2 Occupants X 155 Btuh/occ. = 813 Infiltration: 4,771 X 1.20 X 72.01 X 0.00376, Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 813 EnerqyPro 7.2 by EnergySoft User Number: 6712 ID: Page 38 of 42 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 61112018 ROOM INFORMATION DESIGN CONDITIONS Room Name Stair We// Outdoor Dry Bulb Temperature 112 OF Floor Area 542.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btulhr R-38 RoofAtHoR19 (N) 542.0 X 0.0174 X 77.0 = 726 P 21 Wart (N) 28.0 X 0.0690 X 31.0 = 60 R•21 Wall (E) 274.0 X 0.0690 X 44.0 = 832 Wood Door (E) 24.0 X 0.5000 X 47.0 = 564 R-21 Watl (S) 448.6 X 0.0690 X 38.0 = 1,176 R-21 Wall (S) 523.0 X 0.0690 X 39.1 = 1,.411 'R-13 Wall 200.0 X 0.1020 X 0.0 = 4 x x = x x = Page Total 4,770 Items shown with an asterisk (") denote conduction through an interior surface to another room 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 51w (N) 0.0 X 21.0 + 360.0 X 21.0 = 7,553 52w (E) 0.0 X 21.0 + 90.0 X 41.5 = 3,732 4W (S) 0.0 X 21.0 + 15.6 X 26.0 = 406 53w (S) 0.0 X 21.0 + 90.0 X 26.0 = 2,344 5W (S) 0.0 X 21.0 + 33.8 X 26.0 = 880 2W (S) 0.0 X 21.0 + 43.0 X 2T4 = 1,179 X + X = X + X = X + X = Page Total 16,094 Internal Gain Btulhr Occupants 1 6 1 Occupants X 245 Btuh/occ. = 399 Equipment 542 I Floor Area X 0.50 w/sqft = 925 Infiltration: 1.064 X 1.20. X 22 36 X 37 = 1,058 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 23,246 Latent Gain Btu/hr Occupants 1.6 Occupants X 155J Btuh/occ. = 252 Infiltration: 4,771 X 1.20 X 22.36 X .L 0.003761 482 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 252 EnerqyPro 7.2 by EnergySoft User Number: 6712 ID Page 39 of 42 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 61112018 ROOM INFORMATION DESIGN CONDITIONS Room Name Main level Lot 48B Outdoor Dry Bulb Temperature 112 OF Floor Area 2,695.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Ran e: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38Roof AfflcR19 (N) 2,656.5 X 0,0174 X 77.0 = 3,560 R-21 Wall (N) 938.2 X 0.0690 X 31.0 = 2,007 R-21 Wall (E) 765.2 X 0.0690 X 44.0 = 2,323 Woad Door (E) 82.8 X 0.5000 X 47.0 = 1.946 R-21 Wall (S) 72.0 X 0,0690 X 38.6 = 189 R-21 Wall (S) 641.6 X 0.0690 X 39.1 = 1,731 1R-13 Wall 200.0 X 0.1020 X 0.0 = 0 X X = X X = Page Total 11,756 Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Skyligh122 (N) 0.0 X 20.6 + 13.3 X 80.0 = 1,063 SkyligI2121 (N) 0.0 X 20.6 + 24.9 X 80.0 = 1,991 57w (N) 0.0 X 21.0 + 162.8 X 21.0 = 3.415 2d (E) 37.6 X 19.2 + 58.4 X 39.7 = 3.037 1 W (E) 0.0 X 21.0 + 42.0 X 41.5 = 1,741 54w (S) 0.0 X 19.2 + 72.0 X 24.2 = 1,746 55w (S) 0.0 X 19.2 + 72.0 X 24.2 = 1,746 56w (S) 0.0 X 19.2 + 72.0 X 24.2 = ,7463d (S) 344.4 X 19.2 + 0.0 X 25. ==,605Page L263 Total,092 Internal Gain Btu/hr Occupants 8.1 Occupants X 245 Btuh/occ. = 1,983 Equipment 2, 695 Floor Area X 0.50 w/sgft = 4,599 Infiltration: 1.064 X 1.20 X 111.16 X 37 = 5,261 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 46,691 Latent Gain Btu/hr Occupants 81 Occupants X 155 Btuh/occ. 1,254 Infiltration: 4,771 X 1.20 X 111.16 X 0.00376 = 2,397 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,254 EnerqyFro 7.2byFnergySoft User Number: 6712 ID: Page 40 of 42 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 61112018 ROOM INFORMATION DESIGN CONDITIONS Room Name second level Lot 48B Outdoor Dry Bulb Temperature 112 OF Floor Area 2,284.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Ranae: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' cooIR-3BRoof AllicRl9 (N) 2,277.7 X 0.0174 X 56.0 = R-21 Wall (N) 680.1 X 0.0690 X 23.0 = R-21 Wall (E) 753.5 X 0.0690 X 33.0 = R-21 Wall (S) 634.4 X 0.0690 X 26.0 = R-21 Wall (W) 526.1 X 0.0690 X 33.0 = "R-13 Watt 200.0 X 0.1020 X 0.0 = X X = X X = X X L= Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Skylrght20 9w 8w 58w 11w 12W 13W 59w 60w Orientation (N) (N) (N) (N) (N) (N) (E) (S) (S) Btulhr 2,220 1,079 1,716 1.138 1,198 1 7.3511 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 17.4 6.3 51.2 0.0 16.3 29.2 16.3 0.0 18.1 14.5 18.1 0.0 18.1 72.0 18.1 0.0 18.1 19.3 18.1 0.0 18.1 16.9 18.1 0.0 18.1 34.5 31.8 0.0 18.1 54.6 18.2 0.0 18.1 54.6 18.2 Page Total Btulhr 323 477 263 1,306 350 306 1,097 993 6,1 Internal Gain Btulhr Occupants 6 9 Occupants X 245 Btuh/occ. Equipment 2,284 Floor Area X 0.50 w/sgft Infiltration: 1.064 X 1.20 X 94.20 X 37 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 29,3821 Latent Gain Btulhr Occupants 69 Occupants X 155 Btuh/occ. _ 1,053 Infiltration: 4,771 X 1.20 X 94.20 X 0.00376 2,03i Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1.0631 EnerQvPro 7.2 by EnergySoft User Number. 6712 ID: Page 41 of421 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence 1 61112018 ROOM INFORMATION DESIGN CONDITIONS Room Name second level Lot 48B Outdoor Dry Bulb Temperature 112 OF Floor Area 2,284.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr X X X X = X X — X X X X = X X = X X = X X = X X — Page Total 0 Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 61 W (S) 0.01 X 18.1 + 54.6 X 18.2 = 993 low (S) 0.0 X 18.1 + 33.8 X 18.2 = 615 7ad (lM 150.9 X 16.3 + o o X 30.0 = 2, 465 7bd (KO 111.0 X 16.3 + 0. 0 X 30.0 = 1,813 X + X = X + X = X + X = X + X = X + X = Page Total 5,886 Internal Gain Btu/hr Occupants _ fi•9 Occupants X 245 Btuh/occ. = 1,680 E ui ment 2,284 Floor Area X 0 50 w/sgft = 3,898 Infiltration: 1.064 X 1.201 X 94.20 X 37 4,459 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 29,382 Latent Gain Btu/hr Occupants 6.9 Occupants X 155 Btuh/occ. = 1,063 Infiltration: 4,771 X 1.20 X 94.2X F 2,031 AlrSensible Cr--M ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,063 EnerflyPro 7.2 by Ener vSoft User Number: 6712 ID: Page 42 of 42 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 48B Calculation Date/Time: 13:56, Fri, Jun 01, 2018 CF1 R-PRF-01 Page 1 of 13 Calculation Description: Title 24 Analysis Input File Name: tmpE44B.tmp.xml GENERAL INFORMATION 01 Project Name Lot 48B 02 Calculation Description Title 24 Analysis 03 Project Location Lot 48B The Madison 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3 0 (1016 SP2) 08 Climate Zone CZ15 09 Software Version EnergyPro 7 2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 90 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ftZ) 7267 15 Number of Zones 4 16 Slab Area (ftZ) 4983 17 Number of Stories 2 18 Addition Cond. Floor Area(ftZ) n/a 19 Natural Gas Available Yes 20 Addition Slab Area (ftZ) n/a 21 Glazing Percentage (%) 36.4% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ftZ-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 4.70 in 8.43 -3.73 -79.4% Space Cooling 89.41 6.53 7.3% IAQ Ventilation 0 70 f 0.00 0.0% Water Heating 1. 6 , , &PF:T'P•flEPT- I -1.45 -74.0% Photovoltaic Offset - -DUIL 0 0.00 -- Compliance Energy Total 96. 7 N II 1.35 1.4% RECEIVED JUN 0 6 2018 f1 CITY OFF LA QUINTA Re�igFr; iePNGhibLREV��90�Apl�T9H-00o-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: 2018-06-01 14:01:36 Report Version - CF1 R-04302018-1016 SP2 HERS Provider: CaICERTS ine. Report Generated at: 2018-06-01 13:57:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 48B Calculation Date/Time: 13:56, Fri, Jun 01, 2018 CF1 R-PRF-01 Page 2 of 13 Calculation Description: Title 24 Analysis Input File Name: tmpE44B.tmp.xml ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Efficiency I EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR 46.6 46.0 0.0 46.0 ❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. ❑ Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified. Notes: • Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Window overhangs and/or fins HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High quality insulation installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: • Pipe Insulation, All Lines Registration Number: 218-P010001729H-000-000-0000000-0000 Registration Date/Time: 2018-06-01 14:01:36 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-01 13:57:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 48B Calculation Date/Time: 13:56, Fri, Jun 01, 2018 CF1 R-PRF-01 Page 3 of 13 Calculation Description: Title 24 Analysis Input File Name: tmpE44B.tmp.xml BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Lot48B 7267 1 4 4 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 master Conditioned HVACmstrl 1746 9 DHW Sys 1 n/a stairs Conditioned HVACstair2 542 9 DHW Sys 1 n/a main level Conditioned HVAC grt3 2695 9 DHW Sys 1 n/a 2nd level Conditioned HVAC 2nd4 2284 9 I DHW Sys 1 n/a [ Registration Number: 216-P010001729H-000-000-0000000-0000 Registration Date/Time: 2018-06-01 14:01:36 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-01 13:57:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Lot 48B Calculation Description: Title 24 Analysis Calculation Date/Time: 13:56, Fri, Jun 01, 2018 Input File Name: tmpE44B.tmp.xml Page 4 of 13 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) N Wall master R-21 Wall 0 Right 1029 119.5 90 E Wall master R-21 Wall 90 Front 566 68.3 90 S Wall master R-21 Wall 180 Left 588 59.9 90 W Wall master R-21 Wall 170 specify - 566 213.8 90 Interior Surface master»stairs R-13 Wall n/a n/a 200 0 n/a Roof master R-38 Roof AtticR1 9 n/a n/a 1746 n/a n/a N Wall 2 stairs R-21 Wall 0 Right 388 360 90 E Wall 2 stairs R-21 Wall 90 Front 388 114 90 S Wall 2 stairs R-21 Wall 180 Left I 588 139.4 90 W Wall 2 stairs R-21 Wall ! 170 specify - I 566 43 90 Interior Surface 2 stairs»main level R-13 Wall n/a n/a 200 0 n/a Roofstr stairs R-38 Roof AtticR19 n/a n/a 542 n/a n/a N Wall 3 main level R-21 Wall 0 Right 1101 162.8 90 E Wall 3 main level R-21 Wall 90 Front 986 220.8 90 S Wall 3 main level R-21 Wall 180 Left I 288 216 90 W Wall 3 main level R-21 Wall 170 - specify - 986 344.4 90 Interior Surface 3 main level»2nd level R-13 Wall n/a n/a 200 0 n/a Roof 4 main level R-38 Roof AtticR19 n/a n/a 2656.8 n/a n/a N Wall 4 2nd level R-21 Wall 0 Right I 832 151.9 90 E Wall 4 2nd level R-21 Wall 90 Front 788 34.5 90 S Wall 4 2nd level R-21 Wall 180 Left 832 197.6 90 W Wall 4 2nd level R-21 Wall 270 Back 788 261.921 90 Interior Surface 4 2nd level»master R-13 Wall n/a n/a 200 0 n/a Roof 5 2nd level coolR-38 Roof AtticR19 n/a n/a 2277.7 n/a n/a Registration Number: 218-Po10001729H-000-000-0000000-0000 Registration Date/Time: 2018-06-01 14:01:36 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-01 13:57:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 48B Calculation Date/Time: 13:56, Fri, Jun 01, 2018 CF1 R-PRF-01 Page 5 of 13 Calculation Description: Title 24 Analysis Input File Name: tmpE44B.tmp.xml OPAQUE SURFACES — Cathedral Ceilings 01 02 03 04 05 06 07 08 09 10 11 Name Zone Type Orientatio n Area (ft2) Skylight Area (ft2) Roof Rise (x in 12) Roof Pitch Roof Tilt (deg) Roof Reflectance Roof Emittance Framing Factor Roof main level R-38 Roof AtticR191 Right 38.3 38.2 3 0.25 1404 065 091 01 Roof 2 2nd level coolR-38 Roof AtticR191 Right 6.4 6.3 3 0.25 14.04 0.65 0.91 0.1 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic master Attic Roofmaster Unventilated 3 065 0.91 Yes Yes Attic stairs Attic Roofstairs Unventilated 3 065 091 Yes Yes Attic main level Attic Roofmain level Unventilated 3 0.65 0.91 Yes Yes Attic 2nd level Attic Roof2nd level Unventilated 3 0.65 0.91 I Yes I Yes Registration Number: 218-P010001729H-000-000-0000000-0000 Registration Date/Time: 2018-06-01 14:01:36 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-01 13:57:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot48B Calculation Date/Time: 13:56, Fri, Jun 01, 2018 CF1 R-PRF-01 Page 6 of 13 Calculation Description: Title 24 Analysis Input File Name: tmpE44B.tmp.xml FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 1 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft2) U-factor SHGC Exterior Shading 3w Window N Wall (Right-0) -- -- 1 34.0 0.48 0.23 Insect Screen (default) 7w Window N Wall (Right-0) --- 1 33.0 0.48 0.23 Insect Screen (default) 5d Window N Wall (Right-0) 1 52.5 0.39 0.23 Insect Screen (default) 6d Window E Wall (Front-90) -- - 1 68.3 0.48 0.23 Insect Screen (default) 4d Window S Wall (Left-180) 1 59.9 0.48 0.23 Insect Screen (default) 4d 2 Window W Wall (- specify --170) 1 183.8 0.48 0.23 Insect Screen (default) 6w Window W Wall (- specify --170) 1 30.0 0.48 0.23 Insect Screen (default) 51w Window N Wall 2 (Right-0) - - 1 360.0 0.48 0.23 Insect Screen (default) 52w Window E Wall 2 (Front-90) - 1 90.0 0.48 0.23 Insect Screen (default) 4W Window S Wall 2 (Left-180) ---- ---- 1 1 15.6 0.48 0.23 Insect Screen (default) 53w Window S Wall 2 (Left-180) - - - - 1 90.0 0.48 0.23 Insect Screen (default) 5w Window S Wall 2 (Left-180) 1 33.8 0.48 0.23 Insect Screen (default) 2w Window W Wall 2 (- specify -170) - 1 43.0 0.48 0.23 Insect Screen (default) 57w Window N Wall 3 (Right-0) - --- 1 162.8 0.48 1 0.23 Insect Screen (default) 2d Window E Wall 3 (Front-90) 8.0 12.0 1 96.0 0.39 0.23 Insect Screen (default) 1 W Window E Wall 3 (Front-90) 1 42.0 0.48 0.23 Insect Screen (default) 54w Window S Wall 3 (Left-180) 1 72.0 0.39 0.23 Insect Screen (default) 55w Window S Wall 3 (Left-180) -- - 1 72.0 0.39 0.23 Insect Screen (default) 56w Window S Wall 3 (Left-180) - - - 1 72.0 0.39 0.23 Insect Screen (default) 3d Window W Wall 3 (- specify - 170) 28.7 12.0 1 344.4 0.39 0.23 Insect Screen (default) Skylight22 Skylight Roof (Right-0) 1 133 0.39 0.25 Skylight21 Skylight Roof (Right-0) 1 I 24.9 0.39 0.25 9w Window N Wall 4 (Right-0) ---- ---- 1 29.2 0.39 0.23 Insect Screen (default) 8w Window N Wall 4 (Right-0) I - 1 14.5 0.48 0.23 Insect Screen (default) 58w Window N Wall 4 (Right-0) - - 1 72.0 0.48 0.23 1 Insect Screen (default) 11w Window N Wall 4 (Right-0) ---- ---- 1 19.3 0.48 0.23 Insect Screen (default) 12W Window N Wall 4 (Right-0) ---• I 1 16.9 0.48 0.23 Insect Screen (default) 13W Window I E Wall 4 (Front-90) - I - 1 34.5 0.48 023 Insect Screen (default) 59w Window S Wall 4 (Left-180) 1 546 0.48 ` 0.23 Insect Screen (default) Registration Number: 218-P010001729H-000-000-0000000-0000 Registration Date/Time: 2018-06-01 14:01:36 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-01 13:57:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Lot 48B Calculation Description: Title 24 Analysis Calculation Date/Time: 13:56, Fri, Jun 01, 2018 Input File Name: tmpE44B.tmp.xml Page 7 of 13 60w Window S Wall 4 (Left-180) 1 54.6 0.48 0.23 Insect Screen (default) 61w Window S Wall 4 (Left-180) - 1 54.6 0.48 0.23 Insect Screen (default) 10w Window S Wall 4 (Left-180) -- --- 1 33.8 0.48 0.23 Insect Screen (default) 7ad Window W Wall 4 (Back-270) 16.5 9.1 1.005 150.9 0.39 0.23 Insect Screen (default) 7bd Window W Wall 4 (Back-270) 12.2 9.1 1 111.0 0.39 0.23 Insect Screen (default) Skylight20 Skylight Roof 2 (Right-0) 1 6.3 0.39 0.25 OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2) U-factor 8d garage E Wall 2 24.0 050 1 D E Wall 3 828 0.50 OVERHANGS AND FINS 01 02 03 04 05 06 I 07 08 09 10 11 12 13 14 Overhang I Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 2d 6 0.1 6 6 0 0 0 0 0 I 0 0 0 0 3d 18 0.1 18 18 0 0 0 0 0 0 0 0 0 7ad 18 0.1 18 18 0 0 0 0 0 0 0 0 0 7bd 18 0.1 18 18 0 0 0 0 0 0 0 0 0 Registration Number: 218-P010001729H-000-000-0000000-0000 Registration DateMme: 2018-06-01 14:01:36 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-01 13:57:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 48B Calculation Date/Time: 13:56, Fri, Jun 01, 2018 C F1 R-PRF-01 Page 8 of 13 Calculation Description: Title 24 Analysis Input File Name: tmpE44B.tmp.xml OPAQUE SURFACE CONSTRUCTIONS 01 02 03 ! 04 05 06 07 f Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor I Assembly Layers • Around Roof Joists: R-6.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck., Wood Siding/sheathing/decking Attic Roofmaster Attic Roofs Wood Framed Ceiling in. O.C. R 19 0.059 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof AtticR19 attic) Wood Framed Ceiling 2x4 @ 16 in. O C. R 38 0.025 Over Ceiling Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-21 / 2x6 R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.069 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board • Cavity/Frame: R-13/2x4 R-13 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.0 R 13 0.092 Other Side Finish: Gypsum Board • Around Roof Joists: R-6.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofstairs Attic Roofs Wood Framed Ceiling in. O.C. R 19 0.059 Roofing: Light Roof (Asphalt Shingle) • Around Roof Joists: R-6.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofmain level Attic Roofs Wood Framed Ceiling in. O.C. R 19 0.059 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Sheathing / Insulation: R19 Sheathing • Cavity / Frame: R-38 / 2x4 • Roof Deck: Wood Siding/sheathing/decking R-38 Roof AtticR191 Cathedral Ceilings Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.019 Roofing: Light Roof (Asphalt Shingle) • Around Roof Joists: R-6.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roof2nd level Attic Roofs Wood Framed Ceiling in. O.C. R19 0.059 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 coolR-38 Roof AtticR19 attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Ceiling Joists: R-28.9 insul. Inside Finish: Gypsum Board Sheathing / Insulation: R19 Sheathing Cavity / Frame: R-38 / 2x4 Roof Deck: Wood Siding/sheathing/decking coolR-38 Roof AtticR191 Cathedral Ceilings Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.019 Roofing: Light Roof (Asphalt Shingle) Registration Number: 218-P010001729H-000-000-0000000-0000 Registration Date/Time: 2018-06-01 14:01:36 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-01 13:57:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 48B Calculation Date/Time: 13:56, Fri, Jun 01, 2018 Calculation Description: Title 24 Analysis Input File Name: tmpE44B.tmp.xml CF1 R-PRF-01 Page 9 of 13 SLAB FLOORS 01 02 03 ! 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Slab -on -Grade master 1746 212 None 0.8 No Slab -on -Grade 2 stairs 542 212 None 0.8 No Slab -on -Grade 3 main level 2695 212 None 08 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW (HERS req'd) Pipe Insulation, All Lines DHW Heater 1 (2) 2 .0% WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Uniform Energy Factor / Energy Factor / Efficiency Input Rating / Pilot / Thermal Efficiency Tank Insulation R-value (Int/Ext) Standby Loss / Recovery Eff First Hour Rating / Flow Rate NEEA Heat Pump Brand / Model / Other Tank Location or Ambient Condition DHW Heater 1 Gas Small Storage 2 75 0.68 EF 65,000 Btu/hr R-0/R-0 n/a n/a n/a n/a WATER HEATING - HERS VERIFICATION 01 02 03 04 05 I 06 07 Name Pipe Insulation Parallel Piping Compact Distribution F Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/2 Pipe Insulation, All Lines I n/a n/a I n/a n/a n/a Registration Number: 218-Po10001729H-000-000-0000000-0000 Registration Date/Time: 2018-06-01 14:01:36 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-01 13:57:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 48B Calculation Date/Time: 13:56, Fri, Jun 01, 2018 CF1 R-PRF-01 Calculation Description: Title 24 Analysis Input File Name: tmpE44B.tmp.xml Page 10 of 13 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVACmstr1 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVACstair2 Other Heating and Cooling System Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2 HVAC grt3 Other Heating and Cooling System Heating Component 3 Cooling Component 3 HVAC Fan 3 Air Distribution System 3 HVAC 2nd4 Other Heating and Cooling System Heating Component 4 Cooling Component 4 HVAC Fan 4 Air Distribution System 4 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Efficiency Heating Component 1 CntrlFurnace 1 80 AFUE Heating Component 2 CntrlFurnace 1 80 AFUE Heating Component 3 CntrlFurnace 2 80 AFUE Heating Component 4 CntrlFurnace 1 80 AFUE HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Name System Type Number of Units Efficiency EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 SplitAirCond 1 12.7 16 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component 2 SplitAirCond 1 13 16 1 Not Zonal Single Speed Cooling Component 2-hers-cool Cooling Component 3 SplitAirCond 2 12.7 16 Not Zonal Single Speed Cooling Component 3-hers-cool Cooling Component 4 SplitAirCond 1 I 12.7 16 Not Zonal Single Speed Cooling Component 4-hers-cool Registration Number: 218-Po10001729H-000-000-0000000-0000 Registration Date/Time: 2018-06-01 14:01:36 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-01 13:57:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 48B Calculation Date/Time: 13:56, Fri, Jun 01, 2018 CF1 R-PRF-01 Page 11 of 13 Calculation Description: Title 24 Analysis Input File Name: tmpE44B.tmp.xmi HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required I 350 Required I Required Required Cooling Component 2-hers-cool Required 350 Required ! Required Required Cooling Component 3-hers-cool Required 350 Required Required Required Cooling Component 4-hers-cool Required 350 Required Required Not Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 I 06 07 Name Type Duct Leakage I Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Specified Lower Leakage Target 8 Attic None Air Distribution System 1-hers-dist Air Distribution System 2 DuctsAttic Specified Lower Leakage Target 8 Attic None Air Distribution System 2-hers-dist Air Distribution System 3 DuctsAttic Specified Lower Leakage Target 8 Attic None Air Distribution System 3-hers-dist Air Distribution System 4 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 4-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required Air Distribution System 2-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required Air Distribution System 3-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required Air Distribution System 4-hers-dist Required 5.0 Not Required Not Required Not Required Not Required n/a Registration Number: 218-P010001729H-000-000-0000000-0000 Registration DateMme: 2018-06-01 14:01:36 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-01 13:57:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 48B Calculation Date/Time: 13:56, Fri, Jun 01, 2018 Calculation Description: Title 24 Analysis Input File Name: tmpE44B.tmp.xml CF1 R-PRF-01 Page 12 of 13 HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 I Single Speed PSC Furnace Fan 0.54 HVAC Fan 1-hers-fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.54 HVAC Fan 2-hers-fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.54 HVAC Fan 3-hers-fan HVAC Fan 4 Single Speed PSC Furnace Fan 0.58 HVAC Fan 4-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.54 HVAC Fan 2-hers-fan Required 0.54 HVAC Fan 3-hers-fan Required 0.54 HVAC Fan 4-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 110 0.25 Default 0 Required Registration Number: 218-P010001729H-000-000-0000000-0000 Registration Date/Time: 2018-06-01 14:01:36 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-01 13:57:48 CF1 R-PRF-01 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Lot 48B Calculation Date/Time: 13:56, Fri, Jun 01, 2018 Calculation Description: Title 24 Analysis Input File Name: tmpE44B.tmp.xml Page 13 of 13 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature Tim Scott Company: Signature Date: Scott Design and Title 24, Inc. 2018-06-01 14:01:36 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3 The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Tim Scott L+sifi�C6/ Company: Date Signed: Scott Design and Title 24, Inc. 2018-06-01 14:01:36 Address: License: 77085 Michigan Drive na City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. 0 1 w Easy to Verify at CaICERTS.com Registration Number: 218-Po10001729H-000-000-0000000-0000 Registration Datefrime: 2018-06-01 14:01:36 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 HERS Provider: CaICERTS inc. Report Generated at: 2018-06-01 13:57:48