BRES2018-0420VOICE (760) 777-7125
78-495 CALLE TAMPICO Tit�t D
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 4/25/2019
Permit Type/Subtype: BUILDING RESIDENTIAL/DWELLING - SINGLE FAMILY DETACHED Owner:
Application Number: BRES2018-0420 BRADLEY E. TONKIN TRUSTEE OF THE BRADLY E.
Property Address: 53079 VIA SAVONA TONKIN TRUST
APN: 777380003 53079 VIA SAVONA
Application Description: TONKIN /7,283 SF DWELLING/VB/RES-3/CLASS A-FR/13D LA QUINTA, CA 92253
Property Zoning:
Application Valuation: $638,301.20
Applicant: ! `� \ r
Contractor:
STRACTS INC -ANTON MARINKOVICH D L IL� MARIO A YANEZ CONSTRUCTION
550 S. OLEANDER ROAD PO BOX 580925
PALM SPRINGS, CA 92264 APR 2 5 2019 NORTH PALM SPRINGS, CA 92258
CITY I OF LAQUI(':'.,TA (760)285-1532
DESIGN l & DEVELOPMENT DEPARTMENT Llc. No.: 1026884
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 70001 of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: B License No.: 1026884
Contractor' 'I
OWNER -BUILDER DECLARATION
1 hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
() I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
() I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's
Lender's Address:
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor code, for the performance
of t r which this permit is issued.
have and will maintain workers' campen5atian insurance, as required by
5ectiin 3 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: NORGUARD INSURANCE COMPANY Policy Number: MAWC045971
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Co hall forthwith
comply with those provisions.
s.
Date:. yrL T / Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to buildfn
construction, and hereby authorize representatives of this city to enter u n th
above -mentioned property for inspection purposes.
Date: — �r Cture (Applicant or Agent)
Date: 4/25/2019
Application Number:
BRES2018-0420
Property Address:
53079 VIA SAVONA
APN:
777380003
Application Description:
TONKIN /7,283 SF DWELLING/VB/RES-3/CLASS A-FR/13D
Property Zoning:
Application Valuation:
$638,301.20
Applicant:
STRACTS INC- ANTON MARINKOVICH
550 S. OLEANDER ROAD
PALM SPRINGS, CA 92264
Owner:
BRADLEY E. TONKIN TRUSTEE OF THE BRADLY E.
TONKIN TRUST
53079 VIA SAVONA
LA QUINTA, CA 92253
Contractor:
MARIO A YANEZ CONSTRUCTION
PO BOX 580925
NORTH PALM SPRINGS, CA 92258
(760)285-1532
Llc. No.: 1026884
Detail: 7,283SF SINGLE FAMILY DWELLING - [VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY
APPROACH. 2016 CALIFORNIA BUILDING CODES.
DESCRIPTION ACCOUNT QTY AMOUNT
ART IN PUBLIC PLACES - RESIDENTIAL 270-0000-43201 0 $1,095.75
Total Paid for ART IN PUBLIC PLACES - AIPP: $1,095.75
DESCRIPTION
ACCOUNT
QTY
AMOUNT
BSAS SB1473 FEE
101-0000-20306
0
$26.00
I Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $26.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - CIVIC CENTER
252-0000-43200
0
$942.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - COMMUNITY CENTERS
254-0000-43200
0
$129.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - FIRE PROTECTION
257-0000-43200
0
$433.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF- LIBRARIES
253-0000-43200
0
$344.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - PARK MAINTENANCE
256-0000-43200
0
$40.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - PARKS/REC
251-0000-43200
0
$2,048.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - STREET MAINTENANCE
255-0000-43200
0
$116.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - TRANSPORTATION
250-0000-43200
0
$2,842.00
Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, EA ADDITION 1,000SF
101-0000-42403
0
$122.49
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, EA ADDITION 1,000SF, PC
101-0000-42600
0
$50.40
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, FIRST 1,000SF
101-0000-42403
0
$160.10
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, FIRST 1,OOOSF, PC
101-0000-42600
0
$52.83
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $385.82
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT >7KSF
101-0000-42408
0
$40.02
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT >7KSF PC
101-0000-42600
0
$200.12
Total Paid for GRADING: $240.14
DESCRIPTION
ACCOUNT
QTY
AMOUNT
CONDENSER/COMPRESSOR
101-0000-42402
0
$200.10
DESCRIPTION
ACCOUNT
QTY
AMOUNT
CONDENSER/COMPRESSOR PC
101-0000-42600
0
$133.40
DESCRIPTION
ACCOUNT
CITY
AMOUNT
EXHAUST HOOD
101-0000-42402
0
$13.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
EXHAUST HOOD PC
101-0000-42600
0
$5.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FURNACE
101-0000-42402
0
$200.10
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FURNACE PC
101-0000-42600
0
$133.40
DESCRIPTION
ACCOUNT
CITY
AMOUNT
VENT FAN
101-0000-42402
0
$120.06
DESCRIPTION
ACCOUNT
QTY
AMOUNT
VENT FAN PC
101-0000-42600
0
$48.06
i Total Paid for MECHANICAL: $853.80
DESCRIPTION
ACCOUNT
CITY
AMOUNT
MULTI -SPECIES RESIDENTIAL 0-8 UNITS - 2018 UPDATE
101-0000-20310
0
$1,290.00
Total Paid for MULTI -SPECIES RESIDENTIAL: $1,290.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
NEW CONSTRUCTION PERMIT
101-0000-42400
0
$914.17
Total Paid for NEW CONSTRUCTION PERMIT: $914.17
DESCRIPTION
ACCOUNT
CITY
AMOUNT
NEW CONSTRUCTION PLAN CHECK
101-0000-42600
0
$1,984.21
Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,984.21
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PLAN CHECK DEPOSIT - RESIDENTIAL
101-0000-42600
1
$1,200.00
Total Paid for PLAN CHECK DEPOSIT - RESIDENTIAL: $1,200.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
BUILDING SEWER
101-0000-42401
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
BUILDING SEWER PC
101-0000-42600
0
$18.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FIXTURE/TRAP
101-0000-42401
0
$440.22
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FIXTURE/TRAP PC
101-0000-42600
0
$440.22
DESCRIPTION
ACCOUNT
CITY
AMOUNT
GAS SYSTEM, 5+ OUTLETS
101-0000-42401
0
$40.02
DESCRIPTION
ACCOUNT
CITY
AMOUNT
GAS SYSTEM, 5+ OUTLETS PC
101-0000-42600
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
ROOF DRAIN
101-0000-42401
0
$146.74
DESCRIPTION
ACCOUNT
CITY
AMOUNT
ROOF DRAIN PC
101-0000-42600
0
$146.74
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WATER HEATER/VENT
101-0000-42401
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WATER HEATER/VENT PC
101-0000-42600
0
$16.00
Total Paid for PLUMBING FEES: $1,328.66
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RECORDS MANAGEMENT FEE - MAJOR
101-0000-42416
0
$21.00
Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SMI - RESIDENTIAL
101-0000-20308
0
$82.98
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $82.98
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($1,200.00)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SINGLE FAMILY DETACHED 2018 UPDATE
224-0000-20320
0
$1,200.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SINGLE FAMILY DETACHED 2018 UPDATE
224-0000-20320
0
$1,110.00
Total Paid for TUMF - RESIDENTIAL: $1,110.00
aca
PERMIT #' Seel 20 � IMOy2D
PLAN LOCATION:
Project Address: / ON
Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech
APN #: - & O
Applicant Name:
Address:
City, ST, Zip: ifJ� ►j�/r/
Telephone: 7l�1/ • ��. . C�lS
Email: 4h <;7y✓', exrm
Valuation of Project 5��a—�
Contractor Name:
New SFD Construction:
Conditioned Space
�SF
Address:
City, St, Zip
Garage
Zz S SF
Telephone:
Patio/Porch
�_ SF
Email:
Fire Sprinklers
7�40SF
State Lic: City Bus Lic:
Arch/Eng Name: ���
Construction Type: .-��(/ Occupancy+. ��
Address: tom:- S
Grading:
City, St, Zip y
Telephone: �0•���•� $--/
Bedrooms: Stories: # Units:
Email:
State Lic:�•� G)/ City Bus Lic.10/o Y&O
Property Owner's Name: 6wft A114fft!VAF—
New Commercial / Tenant Improvements:
Address:&W/
Total Building SF
City, ST, Zip .97A
Construction Type: Occupancy:
Telephone: • -57,-04:5)
Email: �• •6d41
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
Coachella Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
(760) 398-5909 — Fax (760) 398-1224
This Box For District Use Only
DEVELOPER FEES PAID
AREA: AMOUNT
LEVEL ONE AMOUNT; LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT:
DATE: RECEIPT: CHECK#: INITIALS
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: Bradley Tonkin (Hideaway)
Owner's Name: Bradley Tonkin
Project Address: 53-079 Via Savona, LaQuinta
Project Description: New SFD
APN: 777-380-003 Tract #:
Type of Development: Residential xx Commercial
Total Square Feet of Building Area: 7,283 s . ft.
Date: April 25, 2019
Phone No. 760-702-0119
Lot #'s.
Industrial
Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under
penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer.
Dated: April 25, 2019 Signature:
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code
17620
Number of Sq.Ft.
Amount per Sq.Ft.
Amount Collected
Gov. Code
65995
7283
$3.79
$27602.57
Building Permit Application Completed: Yes/No
Project
Approval
By: Larry Moen, Director Facilities Dev. & Planning
Agreement Existing Not Subject to Fee
Prior to 1/1/87 Requirement
Note:
Pursuant to AB 181 any room additions or enclosures of 500
sq. ft. or less are exempt from developer fees. Any mobile
homes being relocated within the same school district's
jurisdiction are exempt from developer fees.
Certificate issued by: Laurie Howard Administrative Spec. Signature: ;tt� 1--./ 46,walt"L
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1,1997, requires that this District provide (1) a written notice to the
project appellant, al the tirrtt of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90-day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordaucc with section 66020 of the Goverrunent code and other applicable law, this Notice shall serve to
advise you that the 90-day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
lime or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts an the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extetti_sian will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted.
11/2010
RECORDING REQUESTED BY:
WFG National Title Company
AND WHEN RECORDED MAIL TO:
Bradley E. Tonkin
6001 SW Delker Road
Tualatin, OR 97062
order No.: 17-134475
Escrow No.: F32414
A.P.N.:777.380.003 tra 020-205
AND [;[]l F ECTC.OPY 0 " "r-' anlrlllALr. GY:
r(7l}IiSCASONS CROW.fNC.
SPACE ABOVE THIS LINE 1S FOR RECORDER'S USE
GRANT DEED
THE UNDERSIGNED GRANTOR(S) DECLARE(S)
DOCUMENTARY TRANSFER TAX IS $ 781 .00
[ X ] computed on full value of property conveyed,. or
[ ] computed on full value lass value of liens or encumbrances remaining at time of sale.
[ ] unincorporated area [ X ] City of La Quinta
FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged,
Bill D. Farleigh, Trustee of The Bill D. Farleigh Revocable Trust, Dated January 21, 1983
hereby GRANT(S) to
Bradley E. Tonkin, Trustee of The Bradley E. Tonkin Trust dated
October 31, 2017
the following described real property in the County of Riverside, State of California
See Exhibit "A" attached hereto and made a part hereof.
Commonly known as: 53079 Via Savona (Lot 31/32C) , La Quinta, CA 92253
Dated: December 7, 2017
A notary public or other officer completing this certificate
verifies only the identity of the individual who signed the
document to which this certificate is attached, and not the
truthfuiness, accuracy, or valldlty of that document.
STATE OF t�ll%JbVWr t► QqV
COUNTY OF& &.
On A Z6 t K before me,
The Bill D. Farleigh Revocable Trust, Dated
January 21, 1 3 _
SS. By: BIII D.arlelg rustee
A, a nota2 public,
personally � red I�
c 9 /j
who proved to me n the basis of satisfactory evidence to be the
person(s) whose name(s) is/are subscribed to the within
instrument and acknowledged to me that he/she/they executed
the same In his/her/their authorized capacity(ies), and that by
his/her/their signature(s) on the instrument the person(s), or the
entity upon behalf of which the person(s) acted, executed the
instrument.
/g831
I certify under PENALTY OF PERJURY under the laws of the
State of that the foregoing paragraph Is true and
correct. o" JsCloy NOTARY PUBLIC
CHRISTINE D, VIRCKS
WITNESS my hand and official seal. srATE of wYOMING
COUNTY OF NATRONA
Commissfan Ear Ires Ju 8, 202'1
Signature
(Seal)
(This area for official notary seal)
MAIL TAX STATEMENTS AS DIRECTED ABOVE
Order No.: 17-134475
EXHIBIT "A"
LEGAL DESCRIPTION
THE LAND REFERRED TO HEREIN BELOW IS SITUATED IN THE COUNTY OF RIVERSIDE, STATE OF
CALIFORNIA AND IS DESCRIBED AS FOLLOWS:
PARCEL NO. 1:
LOTS 31 AND 32 OF TRACT NO.29894-3, IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE
OF CALIFORNIA, AS SHOWN BY MAP ON FILE IN BOOK 351, PAGES 3.5 THROUGH 48, INCLUSIVE OF
MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF RIVERSIDE COUNTY, CALIFORNIAAND SHOWN
ON GRANT DEED RECORDED APRIL 13, 2004 AS INSTRUMENT NO.2004-0266760 OF OFFICIAL
RECORDS.
GRANT DEED. REFLECTS PARCEL MERGER NO. 2004-452, AS APPROVED BY THE CITY OF LA QUINTA.
PARCEL NO.2:
NON-EXCLUSIVE EASEMENTS FOR ACCESS, INGRESS, EGRESS, DRAINAGE, MAINTENANCE, REPAIRS
AND FOR OTHER PURPOSES, ALL AS DESCRIBED IN THE DECLARATION.
APN; 777-380-003-5
THB IS TO CERTIFY THAT THIS IS A TRUr
AND C>O -IRLCT COPY OF THE ORIGlP11J.
HEREOF �,
FdDR .^E'ASONS ROW.IWC.
WFG Form No. 3151600 CLTA Preliminary Report Form (06-05-14)
Page 2 of 12
THE HIDEAWAY
PR0pF,P, Y DWNFRS ASSOCIA-RON
January 22, 2019
Mr. and Mrs. Brad Tonkin
6001 SW Delker Road
Tualatin, OR 97062
Re: Lot 31132C at 53079 Via Savona
Construction Document Review 41
Dear Mr. and Mrs. Tonkin:
This correspondence shall serve as notification that the Hideaway Design Review Committee
(DRC) reviewed your construction document submittal at the January 15, 2019 meeting. The
project was approved to start construction subject to the following comments being addressed, in
a revised submittal package, no later t an February 12th for review at the February 19, 2019
meeting.
The committee reviewed the respernse letter provided by Stracts regarding the shed roof
design; however, there seems to be some confusion regarding the request for
modification. The November 1')1 letter expressed the committee's concerns and images
were provided as attachments to the letter that indicated exactly what was expected based
on the November 6" meeting and plan review. The modification being requested will
also allow for ease in installing window coverings on the interior of the home. As this
element is a guest room located at the main entry of the home, privacy will be needed on
occasion. While the committee does not typically review the interior aspects of the
home, they offer this information as a secondary reason to support the requested
modification. An image has been provided again for your review. In addition, the
window panes greatly exceed the guideline allowance at approximately 4-Moot by 5-foot.
2. Please clarify the wall design on the southwest side of the lot where there are elements
that appear to extend over the side yard property line.
3. The committee included the request to add the privacy wall at the stairs on previous
review letters and it has still not been modified. This may not leave been a requirement
on previous homes, but it is included in the current guidelines and the modification is
required.
4. The exterior wall sconces include no specifications on the plans.
5. The roof file coloring is not specified on the Roof plan or Elevations (just the
manufacturer is provided).
6. The Mechanical and Plumbing sheets were missing from the submittal and are required
with your next submission.
7. The lawn extension proposed on the golf course property must be approved by Gerry
Tarsitano on behalf of the Golf Club.
8. Please submit the artificial turf sample for review and approval.
9. The irrigation plan references pots; however, the committee was unable to locate any pots
on the plans.
10. Courtesy comment: There are Ficus proposed at 2' on center which will create a very
dense hedge.
80955 Avenue 52, La Quinta, CA 92253 0 760-393,5210
Building Permit Number:
Project Description: �SFR
Exempt: ❑
(Materials may contain hazardous wastes and
are not subject to recycling provisions)
Construction Debris Management Plan
Plan Submittal Date 2/21/2019
Job Site Address
Owner's Namel
Number, Street, or PO Boxl
City, State, Postal Codel
Owner's Phone Numberlllli
Owner's E-Mail Address
Project Manager's Name
Project Manager's Phone Number
Project Manager's E-mail Address
Builder / Contractor
Number, Street or PO Box
City, State, Postal Code
Project Square Footage
City Approval By
Date of City Approval
Materials To Be Discarded:
53079 Via Savona (Lot #31 & 32C)
Brad & Michelle Tonkin
c/o 40101 Monterey Ave B1-214
Rancho Mirage, CA. 92270
760-702-0119
sunrose.sedonar
Sunrose Corp
760-702-0119
suer_ os0.sedonnnnmr ll.com
Sunrose Corp
40101 Monterey Ave B1-214
Rancho Mirage, CA. 92270
Approx. 7,283 square feet
Renado Gouldlock-DEC/Burrtec Waste
02) 21 ) 10
Product
Tons
Trash
29.50
Not recyclable
Asphalt
0.00
Recyclable
Brick/Block
0.00
Recyclable
Cardboard
0.00
Recyclable
Commingled
0.00
Recyclable
Concrete 1
32.00
1 Recyclable
Drywall
3.50
Recyclable
Donated / Reuse*
0.00
Recyclable
RE E.
IVED
CITY OF LA QUINTA
Ca"M'UNiTy Dr-WEDPMEWT
Product
Masonry (broken)
Plaster
Scrap Metal
Tile (floor)
Tile (roof)
Wood
Landscape Debris
Tons
0.00 Recyclable
8.50 Recyclable
0.00 Recyclable
0.50 Recyclable
0.75 Recyclable
0
*Describe Items
Totals: Rec cle Trash
58-311 29.5
Projected Diversion:
436,3! -
I understand it Is the property owner's responsibility to submit copies of weight tickets or receipts to the District
Environmental Coordinator as these hauls occur. i hereby certify that completion, implementation and adherence of the
Debris Management Plan (DMP) for the above named project shall guarantee that at least 65%n of the jobsite waste is
diverted from landrilling. The remaining material will be recycled or reused- I will divert, for recycling or re -use, remaining
materials generated from the first day of the project through the completion of the project in accordance with Mis plan. This
OMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or
demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still
issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the
DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through
bi-monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved recycier or transfer
Owner / Developer / Project Manager / Supsrintendant Date
THE HIDEAWAY
PROPERTY OWNERS AssomnoN
April 10, 2019
Mr. and Mrs. Brad Tonkin
6001 SW Delker Road
Tualatin, OR 97062
Re: Lot 31132C at 53079 Via Savona
Revised Final Construction Documents
Dear Mr. and Mrs. Tonkin:
This correspondence shall serve as notification from the Hideaway Design Review Committee
(DRC) that your revised final working drawings were approved to start construction; subject to
the surge tank for the pool area having an overflow drain in case there is an issue with the auto
fill.
Please contact Brook Marshall at 760-219-8057 or by email at DRCFacilitator@gmail.com with
any questions or to schedule your Pre -Construction Meeting once a Building Permit has been
obtained.
Sincerely,
THE HIDEAWAYDESIGN REIVIEW C0MjV1ITTEE
By:_
`t✓ 1 r i� Gf.�.�
Title: Y - Date: �. J 0-
cc: stracts
DRC File
Pursuant to Cal. Civil Code, any rejection by the DRC may be appealed to the Board of.Directors for the Association. If you wish to pursue an appeal, ,please contact the Assactatian's property manager directly.
RECEIVED
CITY OF LA QUINTA
Co�1A R k';-VWPMENT
80955 Avenue 52, La Quinta, CA 92253 0 76M93.5210
City of La Quinta
BUILDING AND SAFETY DEPARTMENT
PLAN CHECK COMMENTS
PLAN CHECK NO.: BRES2018-0420
PROJECT ADDRESS: 53079 Via Savona
WORK DESCRIPTION: New Single Family Residence
APPLICANT NAME:
ADDRESS:
STATUS: Approved with Conditions
DATE SUBMITTED: 12/20/18
TEL NO:
EMAIL:
USE
OCCUPANCY
GROUP
FLOOR
AREA
SF
OCCUPANT
LOAD
TYPE OF
CONSTR.
NO. OF
STORIES
FIRE
SPRINKLER
(YIN)
VALUATION
The approval of plans and specifications does not permit the violation of any sections of the California Building Codes,
local ordinances, or state laws.
In an effort to speed up the plan review process, follow the steps provided below to ensure that there is no delay in
processing your application and reviewing your responses to these plan check comments.
• Revised plans and calculations shall incorporate and address all comments marked on the original checked set of
plans, calculations, and this plan check comment list.
• Provide a written response to each comment adjacent to the comment listed
• Cloud the location on the plan where it has been addressed and how.
• Identify, in your response letter, the sheet number, detail, or reference note on the revised plans where the
corrections were made.
■ Time spent searching for the corrected items on the revised plans or calculations may delay the review
and approval process.
PLAN CHECKER: Adam Tekunoff
TEL. NO.: (424) 237-8395
DATE: 12/31 /18
Should you have any questions or need clarification pertaining to the comments made on your project, you may contact
the plan check staff by telephone from 8:00 A.M. to 4:00 P.M.
• Bring the original checked set of plans and calculations along with this comment list to the City of La Quinta.
• Do not submit plans for review with the plan check staff until all comments have been addressed.
• Return this Comment list with separate itemized list showing how the item was resolved and where to find
it on the plans and the Red Marked set of plans along with (3) three complete revised sets of plans,
calculations (if applicable). Defaced, incomplete, indefinite, or faded drawings or calculations will not be
accepted. Failing to provide the information may result in your review being delayed or returned for
additional information.
Paae 1 of 2
A. PERMIT APPLICATION COMMENTS:
1. Structural Engineer needs to stamp and sign all structural sheets
2. Provide note on plans for deferred truss calculations.
END OF PLAN REVIEW
Paae 2 of 2
3rW52018 -ogzo
Z
Coachella Valley Water District
75515 Hovley Lane East
Domestic Water System Flow Analysis Palm Desert, CA 92211
Domestic Water System Flow Analysis (Hydraulic Model)
Requested By: COLE TUVELL Date: 4/15/19
Address: 40101 MONTEREY AVE., STE. B1-214 APN:
RANCHO MIRAGE, CA 92270 Req. Fire Flow: gpm at 20psi for hours.
Contact Name: COLE TUVELL Project Name: VIA SAVONA, LOT 31-32
Phone: 760.218.0566
Email: sunrose.sedona@gmail.com Cell:
Domestic Water System FIRE FLOW ANALYSIS -HYDRANT NEAR LOT 31-32C, VIA SAVONA, HIDEAWAY, LA QUINTA.
Flow Analysis Location: GEO 6-7-10-3, PZ 19-9689
Model Information
Flow Analysis Description ' ' •
• •
Re��7
Test 1 Test 2
Test 3
Test 4
exceeding
Elevation (Ft):
.5
Steady State, Dynamic (psi):
117.57
Residual Pressure (psi):
90.76
Fire Flow Tested (gpm):
3,400
CVWD's
Combined Total:
_N/A
N/A
criteria.
Tested Model Junction: J2292
Duration: 2 hours
Demand Conditions: Peak Day Demand (PDD)
Reservoir No./Level (s): Reservoir 6630/24.91'
Pumps Operating No's: Pumps On
Pressure Zone and HGL: Lower La Quinta (225')
Model: Tamara FF-CVWD DomesticWater 012616
Comments: The domestic water system is capable of providing 3,400 gpm for 2 hours that satisfies CVWD's minimum
pressure, velocity, and/or head loss criteria. This flow can be achieved by using multiple fire hydrants. This
simulated system flow analysis may not Include all facilities that may be required for this development/project.
Please check with Development Services for further information on all required facilities. The theoretical flow to
drop the residual pressure to 20 psi is greater than 5,000 gpm. Please note the theoretical flow exceeds CVWD's
design criteria on the domestic water network.
These results are based on hydraulic modelling and not a guarantee that CVWD's domestic water system will have the capacity to
supply water to the project at the flows or pressures indicated. It is important to note that the capacity of the on -site fire system,
meters, service lines, backflow assemblies and other appurtenances were not considered in this analysis, which may alter actual
flows or pressures. Due to continuous changes in the system, CVWD only considers this system flow analysis valid for six months
from date of modelling/analysis, These system flow analysis comments are for plan check purposes only. The ultimate design
responsibility resides with the Engineer -of -Record for this Project.
Should you have any questions or need additional information, please contact me at (760) 398-2661, ext. 2397.
Completed By: - :_::2
-,,, Page 1 of 1 ENG DS-016
CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET
PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT
Form updated & effective 9/25/2009
Gleen_Sheet approvals are forwarded_ tothe _Building & Safety Department directly by Public Works. Please DO NOT
submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed
below are complete. Incomplete applications or applications which cannot be processed will be returned to applicant.
Date: 02 /21 12018 Developer: Sunrose Corporation
Tract No.: 29894-3 Tract Name: Hideaway
Address(s): 53-079 Via Savona, La Quinta CA 92253
Lot No.(s):31-32C
Phone Number: (760 1 218-0566
The following are the requirements for Public Works Clearance to authorize issuance of a building permit from the
Building & Safety Department:
❖ CUSTOM HOMES: PROVIDE ITEMS #2 #3 #4 #5 & #7 BELOW
❖ TRACT HOMES: PROVIDE ITEMS #1, #2 #3 & #5 BELOW
❖ COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1 #2 #3 #5 & #7 BELOW
❖ WALLS SIGNS OTHER: PROVIDE ITEM #6 BELOW
2
3
4
5.
6.
7.
Attach Pad Elevation Certificates in compliance with the approved design elevation for building pad (maximum
allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of current date).
If a precise grading plan creates the pad for approval, please withhold green sheet submittal until a Pad Elevation
Certificate can be provided.
Attach geotechnical certification of grading plan compliance including compaction reports from a licensed Soils
Engineer. Recently rough graded residential developments which have a previously approved geotechnical
certification are exempt from this requirement.
Attach recorded final map or title information/grant deed showing proposed building locations are legal lots.
Complete the attached <1 acre per lot or infill project Fugitive Dust Control project information form, PM10 plan &
agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy plan.
PM10 plans for commercial & residential developments (beyond 1 lot) are submitted separately with grading plans
& are subject to additional requirements. A current PM10 certification number is required.
Attach a copy of the rough or precise grading plan to the Public Works Department showing building location(s)
for pad elevation verification. AO flood zone developments will require an approved flood plain development plan.
Attach supporting documentation for wall plan, monument sign, grease trap or special facility installations.
Complete and sign the attached water quality management plan (WQMP) exemption form, if applicable. PW
approved building construction projects require either a WQMP or a completed WQMP exemption form.
Approved maps/plans may be viewed at the following link: h#tp//www.)a-guinta_org/PlanCheck/m searah.asox
I have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently
complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to my findings,
the above project may be released for building permit issuance.
This section completed by City staff.
Recommended by Date: 1 %0
Public Works Distribution: ( L- }-Green Sheet to Building & Safety
( ) Green Sheet to Planning Department
Declined for approval for reason(s) as follow(s), please correct and resubmit:
TAChecklists - Forms & Applications\Fonns & ApplicationsMEEN SHEET cove
City of La Quinta - PM10 Fugitive Dust Control Project Information
Construction Phase PM10 Agreement (<1 acre/lot or Infill Project)
Pro ect Information
Project Phase
(check one)
Construction
❑ Demolition
i Total Acres in Active
Construction (<1 acre per
Lot): 24771
PM10 Contact
Information
Contractor: Sunrose Corporation
Project Name: Tonkin Residence
Project Tract/Lot Numbers: 29894-3 / Lot 31-32C
Project Street Address: 53-079 Via Savona
La Quinta, CA 92253
Anticipated Start Date: 02 121 / 2018Anticipated Completion Date: 02 / 21 / 2018
Please note: Dust control is required 24 hours a day, 7 days a week, regardless of
construction status. Person listed below is responsible for dust control during business and
non -business hours.
Name: I Cole Tuvell
Title: I Administration
Company Name Sunrose Corporation
Mailing Address: 140101 Monterey Ave. 131-214
Cam: Stater ZIP Code: Rancho Mirage, CA 92270
Primary Phone #: 760-218-0566
Fax #: _
24 Hour Emergency
Phone#: 1 760-218-0566
Cell Phone #: I Same
Email Address: sunrose.sedona@gmail.com
PM10 Certificate #:
CV1802-005850-5908
The above_ stated property owner (or authorized representative):
❖ Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to SCAQMD
Rules 403, 403.1, 401, 402, 201, 203 and PERP;
❖ Shall constitute an Agreement to comply with all project conditions as identified in the approved dust control plan.
❖ Acknowledges that dust control is required twenty-four (24) hours a day, seven (7) days a week, throughout the
period of project performance, regardless of project size or status;
❖ Shall ensure that each and every contractor, subcontractor and all other persons associated with the project shall
be in continuous compliance with all requirements of the approved dust control plan;
❖ Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the dust
control plan are necessary;
❖ Shall authorize representatives of City/County to enter the property for inspection and/or abatement purposes;
❖ Shall hold harmless the City/County and its representatives from liability for any actions related to this dust control
plan or any City/County initiated abatement activities.
Signature of Property Owner or Authorized Representative Date
TACheeklists - Forms & Applications\Fonns & Applications\GREEN SHEET cover & PM10 less than 1 Acre Revised 9-25-09.dee
Water Quality Manaaement Plan (WQMP) Exemption Form - Whitewater River Region
Documentation of I?roiect Not Requiring a WQMP but Reguirlrt Site Design BMPs and Source Control BMPs 1
by Entitlement Conditions of Approval or Permit Conditions — WQMP Required for the Listed Change of Land
Uses or for Changes of Pollutant Stream (All Questions Below Must be Answered "No" To Exempt Project)
Yes
No
Entitlement or construction of new single-family hillside residence(s) that create 10,000 square feet, or
more, of impervious area where the pre -development natural slope is 25% or greater?
❑
Entitlement or construction of new single-family hillside residence(s) that create 10,000 square feet, or
more, of impervious area where the pre -development natural slope is 10% or greater where erosive
soil conditions are known?
❑
❑✓
Entitlement or construction of new commercial and industrial development(s) of 100,000 square feet
or more?
Entitlement or construction of new automotive repair shop(s) including body, upholstery, paint,
exhaust, tire, transmission, engine or other automotive specialty repair. [Standard Industrial
Classification SIC codes 5013, 7532. 7533, 7534, 7537, 7538, and 7539 ?
❑
❑
✓❑
Entitlement or construction of new retail gasoline outlets disturbing greater than 5,000 square feet?
❑
Entitlement or construction of new restaurant(s) (or potential restaurant shell space) disturbing greater
than 5,000 square feet?
❑
Entitlement or construction of new home subdivisions with 10 or more housing units?
❑
`❑
Entitlement or construction of new parking lot(s) of 5,000 square feet or more, or with 25 or more
parkingspaces, and potentiallyexposed to Urban Runoff?
El
❑
Applicant
Information
Name and Title
Mike Tuvell, President
Company
Sunrose Corporation
Phone
760-218-0566
Email
sunrose.sedona@gmail.com
Project Information
Project Name
Type (SFH, Multi -Family, Commercial, Etc.)
Tonkin Residence
SFR
Location or Street Address
53-079 Via Savona
Nearest Cross Streets
Via Mallorca
Municipality/County/Zip Code
La Quinta
Tract Number(s) and/or Assessor Parcel Number(s)
29894-3 / 777-380-003
Other Location Information
Watershed
Whitewater River
Source Control BMP Information
Size of Project Area (nearest 0.1 acre)
24771
Project Area managed with Site Design or Low
Impact Development (LID) BMPs (nearest 0.1 acre)
Is the project subject to onsite retention by City
ordinance or policy?
yes
Name of the Entity that will implement, operate, and
maintain the Source Control BMPs
Contact Name
Sunrose Corporation
Cole Tuvell
Street or Mailing Address
City
40101 Monterey Ave. B1-214
Rancho Mirage
Zip Code
92270
Phone
760-218-0566
TACheckllsts - Forms & Applications\Forms & Applications\GREEN SHEET cover & PM10 less than 1 Acre Revised 9-25-09.doc
Check Item
To be
Performed
Source Control BMP Requirements - All Projects Require Non -Structural BMP Source Control
Non -Structural BMP (See Appendix H, Section 4.5.2.1)
Ongoing Irrigation System and Landscape Maintenance
Ongoing Litter Control
Ongoing Drainage System Inspection & Maintenance
Education/Training for Property Owner, Operators, Occupants, or Employees
Activity Restrictions — Prohibition of Debris Blowing/Sweeping/Washing into Street/Storm Drain, Closed
Trash Lids, Restriction of Vehicle Washing
Ongoing Street Sweeping at Private Streets and Private Parking Lots
Source Control BMP Requirements — Small Sloped Lots, Small Commercial, <10 Unit
Subdivisions, <5,000 Square Ft. Parking Lots, Etc.
Structural BMP (See Appendix H, Section 4.5.2.2)
Storm Drain Inlet Stenciling and Signage
Landscape and Irrigation System Design to Minimize Erosion & Nuisance Runoff
Protection of Slopes and Channels to Minimize Erosion
Check Item
To be
Provided
Multi -Family Project Use of Community Car Wash Racks
Wash Water Controls for Food Preparation Areas to Use Sanitary Sewer
Fueling Area (Design & Maintenance) Including PCC Surface, Canopy & Spill Prevention
Air/Water Supply Area Drainage (Design & Maintenance) Including Spill Area Containment
Trash Storage Areas (Design & Maintenance) Including Attached Lids, Storm Water Controls
❑
Loading Docks (Design & Maintenance) Including Storm Water Controls, Dry & Frequent Cleaning
Procedures
Maintenance Bays (Design & Maintenance) Including Indoor Location & Storm Water Containment
Vehicle and Equipment Wash Areas (Design & Maintenance) Including Canopy & Containment
Outdoor Material Storage Areas (Design & Maintenance) Including Canopy & Containment
Outdoor Work Areas or Processing Areas (Design & Maintenance) Including Canopy & Containment
CC&R's, Maintenance Agreements or Other mechanisms will be used to ensure the ongoing operation,
maintenance, funding, transfer and implementation of the project -specific WQMP requirements. Legal
description and plat stamped by Registered Surveyor to be attached to the applicable CC&R or
Maintenance Agreement for recordation at Riverside County. (Optional Requirement to be reviewed on
a Project by Project basis)
BMP Acknowledgement
The applicant shall comply with listed BMPs and applicable
provisions of the City's NPDES stormwater discharge permit,
Signature:
LQMC Sections 8.70.010 et seq. (Stormwater Management and I
Discharge Controls), and 13.24.170 (Clean Air/Clean Water); Print Name: Cole Tuvell
Riverside County Ordinance No. 457; the California Regional
Water Quality Control Board — Colorado River Basin Region Title: Administration
Board Order No. R7-2008-0001 and the State Water Resources
Control Board's Order No. 99-08-DWQ. Date: 02 121 12018
Phone: (760 218-0566
TACheckllsts - Fonns & ApplicationslFonns & Applications\GREEN SHEET cover & PM10 less than 1 Acre Revised 9-25-09.doc
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Tonkin Res. Calculation Date/Time: 09:01, Thu, Dec 06, 2018
Calculation Description: Title 24 Analysis
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribdl6x
CF1 R-PRF-01
Page 1 of 15
GENERAL INFORMATION
01
Project Name
Tonkin Res.
02
Calculation Description
Title 24 Analysis
03
Project Location
Lot 31 & 32C. The Hideaway
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.3.1 (1149)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.2
10
Building Type
Single Famil
11
Front Orientation (deg/Cardinal)
135
12
Project Scope
Newly Constru
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ftZ)
17283
15
Number of Zones
5
16
Slab Area (ftZ)
6269
17
Number of Stories
1
18
Addition Cond. Floor Area(ftZ)
n/a
19
Natural Gas Available
Yes
20
Addition Slab Area (ftZ)
n/a
21
Glazing Percentage (%)
34.2%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ftZ-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
3.04
5.56
-2.52
-82.9%
Space Cooling
82.99
73.29
9.70
11.7%
IAQ Ventilation
0-79
0.79
0.00
0 °
Water Heating
CA I
Y OF LA20
�
9.04
-6-79 i 1et"tIldilmu
Photovoltaic Offset
QUILDINQ
DiVISIQN
0.00
0.00
Compliance Energy Total
REVIEWED IE FOR
88.68
0.39 J
0.4%
CODE �'LL v !UIrS
C MPLIANCE , CITY OF LA QUZNTA
qDATA 10 1� COMMUN M DEVELOPMENT
Registration Number: 218-P010323021A-000-000-0000000-0000 Registration Date/Time: 2018-12-06 09:27:42 HERS Provider: CaICERTS i
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Tonkin Res. Calculation Date/Time: 09:01, Thu, Dec 06, 2018
Calculation Description: Title 24 Analysis
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribd16x
CF1 R-PRF-01
Page 2 of 15
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery
Final Proposed EDR
47.9 47.7 0.0
47.7
❑
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV)
renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified.
Notes:
• Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High quality insulation installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Verified Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Low -leakage Air Handling Unit
Domestic Hot Water System Verifications:
-- None --
Registration Number: 218-P010323021A-000-000-0000000-0000 Registration Date/Time: 2018-12-06 09:27:42 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Tonkin Res Calculation Date/Time: 09:01, Thu, Dec 06, 2018
Calculation Description: Title 24 Analysis
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribd16x
CFI R-PRF-01
Page 3 of 15
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Tonkin Res.
7283
1
6
5
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Master Suite
Conditioned
HVAC-Master1
1361
10
DHW Sys 1
n/a
Living Space
Conditioned
HVAC-Great/Living/Kit. /D2
3292
13.4
DHW Sys 1
n/a
Bdrms 2
Conditioned
HVAC-Great/Living/Kit. /D2
345
10
DHW Sys 1
n/a
Casita Zone
Conditioned
HVAC-Casita3
1271
10.9
DHW Sys 1
n/a
2nd Floor
Conditioned
HVAC-2nd Floor4
1014
9.5
DHW Sys 1
n/a
Registration Number: 218-P010323021A-000-000-0000000-0000 Registration Date/Time: 2018-12-06 09:27:42 HERS Provider: CaiCERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Tonkin Res. Calculation Date/Time: 09:01, Thu, Dec 06, 2018
Calculation Description: Title 24 Analysis
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18 ribd16x
CF1 R-PRF-01
Page 4 of 15
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
I Orientation
Gross Area (ft2)
Window & Door Area (W)
Tilt (deg)
75d Wall
Master Suite
R-21 Wall
75
- specify -
290
18.9
90
165d Wall
Master Suite
R-21 Wall
165
- specify -
350
0
90
255d Wall
Master Suite
R-21 Wall
255
- specify -
540
106.3
90
345d Wall
Master Suite
R-21 Wall
345
- specify -
280
104
90
Interior Surface
Master Suite»Living Space
R-0 Interior Surface
n/a
n/a
530
0
n/a
Roof
Master Suite
R-38 Roof Attic R19 High
n/a
n/a
1361
n/a
n/a
NE Wall
Living Space
R-21 Wall
45
Right
633
195
90
SE Wall
Living Space
R-21 Wall
135
Front
1007
405
90
165d Wall 2
Living Space
R-21 Wall
165
specify -
140
80
90
SW Wall
Living Space
R-21 Wall
225
Left
608
98
90
NW Wall
Living Space
R-21 Wall
315
Back
970
530
90
345d Wall 2
Living Space
R-21 Wall
165
specify -
80
32
90
Interior Surface 2
Living Space»Master Suite
R-0 Interior Surface
n/a
n/a
530
0
n/a
Interior Surface 3
Living Space»Bdrms 2
R-0 Interior Surface
n/a
n/a
360
0
n/a
Roof 2
Living Space
R-38 Roof Attic R19 High
n/a
n/a
3292
n/a
n/a
NE Wall 2
Bdrms 2
R-21 Wall
45
Right
195
74
90
SE Wall 2
Bdrms 2
R-21 Wall
135
Front
175
0
90
NW Wall 2
Bdrms 2
R-21 Wall
315
Back
70
0
90
Interior Surface 4
Bdrms 2»Living Space
R-0 Interior Surface
n/a
n/a
360
0
n/a
Roof 3
Bdrms 2
R-38 Roof Attic R19 High
n/a
n/a
345
n/a
n/a
75d Wall 2
Casita Zone
R-21 Wall
75
specify -
429
99.1
90
165d Wall 3
Casita Zone
R-21 Wall
165
- specify -
466
214.4
90
255d Wall 2
Casita Zone
R-21 Wall
255
specify -
380
46.5
90
345d Wall 3
Casita Zone
R-21 Wall
345
specify -
507
162.4
90
Interior Surface 5
Casita Zone»Living Space
R-0 Interior Surface
n/a
n/a
530
0
n/a
Roof 4
Casita Zone
R-38 Roof Attic R19 High
n/a
n/a
1271
n/a
n/a
75d Wall 3
2nd Floor
R-21 Wall
75
specify -
428
76.3
90
165d Wall 4
2nd Floor
R-21 Wall
165
specify -
276
106
90
255d Wall 3
2nd Floor
R-21 Wall
255
specify -
428
49.6
90
345d Wall 4
2nd Floor
R-21 Wall
345
specify -
276
92
90
Registration Number: 218-P010323021A-000-000-0000000-0000 Registration Date/Time: 2018-12-06 09:27:42 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Tonkin Res. Calculation Date/Time: 09:01, Thu, Dec 06, 2018
Calculation Description: Title 24 Analysis
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribd16x
CFI R-PRF-01
Page 5 of 15
Interior Surface 6
2nd Floor —Living Space
R-0 Interior Surface
n/a
n/a
530
0
n/a
Roof 5
2nd Floor
R-38 Roof Attic R19 High
n/a
n/a
1014
n/a
n/a
Raised Floor
2nd Floor
R-19 Floor
n/a
n/a
371
n/a
n/a
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Master Suite
Attic RoofMaster Suite
Unventilated
3
0.1
0.85
No
No
Attic Living Space
Attic RoofLiving Space
, Unventilated
3
0.1
0.85
No
No
Attic Bdrms 2
Attic RoofBdrms 2
Unventilated
3
0.1
0.85
No
No
Attic Casita Zone
Attic RoofCasita Zone
Unventilated
3
0.1
0.85
No
No
Attic 2nd Floor
Attic Roof2nd Floor
Unventilated
3
0.1
0.85
No
No
Registration Number: 218-Po10323021A-000-000-0000000-0000 Registration Date/Time: 2018-12-06 09:27:42 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Tonkin Res. Calculation Date/Time: 09:01, Thu, Dec 06, 2018
Calculation Description: Title 24 Analysis
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribd16x
CF1 R-PRF-01
Page 6 of 15
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft2)
U-factor
SHGC
Exterior Shading
x
Window
75d Wall (- specify --75)
-
-
I 1
6.3
025
0.16
Insect Screen (default)
Y
Window
75d Wall (- specify --75)
-
1
6.3
0.25
0.16
Insect Screen (default)
Z
Window
75d Wall (- specify --75)
-
--
1
6.3
025
j 0.16
I Insect Screen (default)
M
Window
255d Wall (- specify --255)
1
6.3
0.25
0.16
Insect Screen (default)
16
Window
255d Wall (- specify --255)
10.0
8.0
1
80.0
0.41
0.21
Insect Screen (default)
15
Window
255d Wall (- specify --255)
---
----
1
20.0
0.39
0.18
Insect Screen (default)
14
Window
345d Wall (- specify --345)
--
1
104.0
0.41
0.21
Insect Screen (default)
K
Window
NE Wall (Right-45)
---
-
1
130.0
0.25
0.16
Insect Screen (default)
9
Window
NE Wall (Right-45)
---
-
1
40.0
0.39 1
0.18
Insect Screen (default)
J
Window
NE Wall (Right-45)
1
25.0
0.25
0.16
Insect Screen (default)
2
Window
SE Wall (Front-135)
12.5
8.0
1
100.0
0.41
0.21
Insect Screen (default)
B
Window
SE Wall (Front-135)
6.5
10.0
1
65.0
0.25
0.16
Insect Screen (default)
1
Window
SE Wall (Front-135)
8.0
10.0
1
80.0
0.25
0-16
Insect Screen (default)
A
Window
SE Wall (Front-135)
6.5
10.0
1
65.0
0.25
0.16
Insect Screen (default)
AA
Window
SE Wall (Front-135)
1
80.0
0.25
0.16
Insect Screen (default)
CC
Window
SE Wall (Front-135)
1
7.5
0.25
0.16
Insect Screen (default)
DID
Window
SE Wall (Front-135)
----
-
1
7.5
0.25
0.16
Insect Screen (default)
AA 2
Window
165d Wall 2 (- specify --165)
-
-
1
80.0
0.25
0-16
Insect Screen (default)
D
Window
SW Wall (Left-225)
1
16.0
0.25
0.16
Insect Screen (default)
C
Window
SW Wall (Left-225)
5.0
8.0
1
40.0
0.25
0.16
Insect Screen (default)
BB
Window
SW Wall (Left-225)
---
---
1
10.0
0.25
0.16
Insect Screen (default)
BB 2
Window
SW Wall (Left-225)
---
1
11.0
0.25
0.16
Insect Screen (default)
BB 3
Window
SW Wall (Left-225)
1
11.0
0.25
0.16
Insect Screen (default)
BB 4
Window
SW Wall (Left-225)
1
10.0
0.25
0.16
Insect Screen (default)
13
Window
NW Wall (Back-315)
30.0
10.0
1
300.0
0.41
0.21
Insect Screen (default)
12
Window
NW Wall (Back-315)
5.0
10.0
1
50.0
0.41
0.21
Insect Screen (default)
11
Window
NW Wall (Back-315)
---
•-••
1
150.0
0.41
0.21
Insect Screen (default)
EE
Window
NW Wall (Back-315)
1
7.5
0-25
0.16
Insect Screen (default)
FF
Window
NW Wall (Back-315)
-
1
7.5
0.25
0.16
Insect Screen (default)
Registration Number: 218-P010323021A-000-000-0000000-0000 Registration Date/Time: 2018-12-06 09:27:42 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Tonkin Res. Calculation DatelTime: 09:01, Thu, Dec 06, 2018
Calculation Description: Title 24 Analysis
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribd16x
CF1 R-PRF-01
Page 7 of 15
GG
Window
NW Wall (Back-315)
-
-
1
7.5
0-25
0.16
Insect Screen (default)
HH
Window
NW Wall (Back-315)
1
7.5
0.25
0.16
Insect Screen (default)
L
Window
345d Wall 2 (- specify --165)
4.0
8.0
1
32.0
0.25
0.16
Insect Screen (default)
8
Window
NE Wall 2 (Right-45)
--
- 1
1
68.0
0.41
0.21
Insect Screen (default)
H
Window
NE Wall 2 (Right-45)
--
-
1
6.0
0.25
0.16
Insect Screen (default)
W
Window
75d Wall 2 (- specify --75)
2.5
3.0
1
7.5
0.25
0.16
Insect Screen (default)
19
Window
75d Wall 2 (- specify --75)
2.5
8.0
1
20.0
0.39
0.18
Insect Screen (default)
U
Window
75d Wall 2 (- specify --75)
---
-
1
44.0
0-25
0.16
Insect Screen (default)
NN
Window
75d Wall 2 (- specify --75)
--
-
1
4.6
0-25
0-16
Insect Screen (default)
PP{
Window
75d Wall 2 (- specify --75)
---
1
4.6
0.25
0.16
Insect Screen (default)
QQ
Window
75d Wall 2 (- specify --75)
-
1
4.6
0.25
0.16
Insect Screen (default)
RR
Window
75d Wall 2 (- specify --75)
-
-
1
4.6
0.25
0.16
Insect Screen (default)
SS
Window
75d Wall 2 (- specify --75)
--•
1
4.6
0.25
0.16
Insect Screen (default)
TT
Window
75d Wall 2 (- specify --75)
---
1
46
0.25
0.16
Insect Screen (default)
U 2
Window
165d Wall 3 (- specify --165)
-
1
154.0
0.25
0.16
Insect Screen (default)
T
Window
165d Wall 3 (- specify -165)
•• •
1
6.0
0.25
0-16
Insect Screen (default)
S
Window
165d Wall 3 (- specify --165)
--
1
6.0
0.25
0.16
Insect Screen (default)
R
Window
165d Wall 3 (- specify --165)
1
30.0
0.25
0.16
Insect Screen (default)
AF
Window
165d Wall 3 (- specify --165)
-
1
4.6
0.25
0.16
Insect Screen (default)
AG
Window
165d Wall 3 (- specify --165)
1
4.6
0.25
0.16
Insect Screen (default)
AH
Window
165d Wall 3 (- specify --165)
1
4.6
0.25
0.16
Insect Screen (default)
AJ
Window
165d Wall 3 (- specify --165)
-
1
4.6
0.25 1
0.16
Insect Screen (default)
Q
Window
255d Wall 2 (- specify --255)
1
6.3
0.25
0.16
Insect Screen (default)
P
Window
255d Wall 2 (- specify --255)
-
1
6.3
0.25
0.16
Insect Screen (default)
N
Window
255d Wall 2 (- specify --255)
--
1
6.3
0.25
0.16
Insect Screen (default)
YY
Window
255d Wall 2 (- specify --255)
I
1
4.6
0.25
0.16
Insect Screen (default)
ZZ
Window
255d Wall 2 (- specify --255)
---
1
4.6
0-25
0.16
Insect Screen (default)
AB
Window
255d Wall 2 (- specify -255)
----
1
4.6
0.25
0.16
Insect Screen (default)
AC
Window
255d Wall 2 (- specify --255)
--
-
1
4.6
0.25
0.16
Insect Screen (default)
AD
Window
255d Wall 2 (- specify --255)
--
-
1
4.6
0.25
0.16
Insect Screen (default)
AE
Window
255d Wall 2 (- specify --255)
----
-
1
4.6
0.25
0.16
Insect Screen (default)
142
Window
345d Wall 3 (- specify --345)
1
104.0
0.41
0.21
Insect Screen (default)
V
Window
345d Wall 3 (- specify --345)
1
16.0
0.25
0.16
Insect Screen (default)
Registration Number. 218-P010323021A-000-000-0000000-0000 Registration Date/Time: 2018-12-06 09:27:42 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1 R-PRF-01
Project Name: Tonkin Res.
Calculation Description: Title 24 Analysis
Calculation Date/Time: 09:01, Thu, Dec 06, 2018 Page 8 of 15
Input File Name: Hideaway 31-32C-Tonkin-Stracts-18.ribd16x
JJ
Window
345d Wall 3 (- specify --345)
1
6.0
0.25
0.16
Insect Screen (default)
KK
Window
345d Wall 3 (- specify --345)
1
6.0
0.25
0.16
Insect Screen (default)
LL
Window
345d Wall 3 (- specify --345)
-
---
1
6.0
0.25
0.16
Insect Screen (default)
MM
Window
345d Wall 3 (- specify --345)
-
--
1
6.0
0.25
0.16
Insect Screen (default)
UU
Window
345d Wall 3 (- specify --345)
1
4.6
0.25
0.16
Insect Screen (default)
VV
Window
345d Wall 3 (- specify --345)
1
4.6
0.25
0.16
Insect Screen (default)
WW
Window
345d Wall 3 (- specify --345)
1
4.6
0.25
0.16
Insect Screen (default)
XX
Window
345d Wall 3 (- specify --345)
1
4.6
0.25
0.16
Insect Screen (default)
AL
Window
75d Wall 3 (- specify --75)
-
-
1
25.0
0.25
0.16
Insect Screen (default)
52
Window
75d Wall 3 (- specify --75)
-
--
1
40.0
0.39
0.18
Insect Screen (default)
AL 2
Window
75d Wall 3 (- specify --75)
1
11.3
0.25
I 0.16
Insect Screen (default)
AM
Window
165d Wall 4 (- specify --165)
----
1
30.0
0.25
0.16
Insect Screen (default)
51
Window
165d Wall 4 (- specify --165)
9.5
8.0
1
76-0
0.39
0.18
Insect Screen (default)
AV
Window
255d Wall 3 (- specify -255)
1
11.3
0.25
0.16
Insect Screen (default)
AT
Window
255d Wall 3 (- specify --255)
---
-
1
11.3
0.25
0.16
Insect Screen (default)
AS
Window
255d Wall 3 (- specify -255)
-
1
6.0
0.25
0.16
Insect Screen (default)
AR
Window
255d Wall 3 (- specify --255)
--
1
6.0
1 0.25
0.16
Insect Screen (default)
AQ
Window
255d Wall 3 (- specify -255)
----
--
1
5.0
1 0.25
0.16
Insect Screen (default)
AP
Window
255d Wall 3 (- specify --255)
-
1
5.0
0.25
0.16
Insect Screen (default)
AN
Window
255d Wall 3 (- specify --255)
----
--
1
5.0
0.25
0.16
Insect Screen (default)
50
Window
345d Wall 4 (- specify --345)
8.5
8.0
1
68.0
0.39
0.18
Insect Screen (default)
49
Window
345d Wall 4 (- specify --345)
3.0
8.0
1
24.0
0.39
018
Insect Screen (default)
Registration Number: 218-Po10323021A-000-000-0000000-0000 Registration Date/Time: 2018-12-0609:27:42 HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Tonkin Res. Calculation Date/Time: 09:01, Thu, Dec 06, 2018
Calculation Description: Title 24 Analysis
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribd16x
CF1 R-PRF-01
Page 9 of 15
OVERHANGS AND FINS
01
02 03
04
05
06
07
08
09 I 10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
16
8
0.1
8
8
0
0
0
0
0
0
0
0
0
2
10
0.1
10
10
0
0
0
0
0
0
0
0
0
B
10
0.1
10
10
0
0
0
0
0
0
0
0
0
1
10
0.1
10
10
0
0
0
0
0
0
0
0
0
A
10
0.1
10
10
0
0
0
0
0
0
0
0
0
C
12
0.1
12
12
0
0
0
0
0
0
0
0
0
13
16
0.1
16
16
0
0
0
0
0
0
0
0
0
12
14
0.1
14
14
0
0
0
0
0
0
0
0
0
L
20
0.1
20
20
0
0
0
0
0
0
0
0
0
W
8
0.1
8
8
0
0
0
0
0
0
0
0
0
19
8
0.1
8
8
0
0
0
0
0
0
0
0
0
51
10
0.1
10
10
0
0
0
0
0
0
0
0
0
50
16
0.1
16
16
0
0
0
0
0
0
0
0
0
49
16
0.1
16
16
0
0
0
0
0
0
0
0
0
Registration Number: 21 8-Po10323021A-000-000-0o00o00-0000 Registration Date/Tme: 2018-12-06 09:27:42 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Tonkin Res. Calculation Date/Time: 09:01, Thu, Dec 06, 2018
Calculation Description: Title 24 Analysis
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribd16x
CF1 R-PRF-01
Page 10 of 15
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-factor
Assembly Layers
Under Roof Joists: R-6.0 insul.
Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofMaster Suite
Attic Roofs
Wood Framed Ceiling
in. O.0
R 19
0.052
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic R19 High
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Ceiling Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
R-21 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in O C.
R 21
0.069
Exterior Finish: 3 Coat Stucco
• Inside Finish: Gypsum Board
• Cavity / Frame: no insul. / 2x4
R-0 Interior Surface
Interior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
none
0.277
Other Side Finish: Gypsum Board
Under Roof Joists: R-6.0 insul.
• Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofLiving Space
Attic Roofs
Wood Framed Ceiling
in. 0 C.
R 19
0.052
Roofing: Light Roof (Asphalt Shingle)
• Under Roof Joists: R-6.0 insul.
• Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofBdrms 2
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 19
0.052
Roofing: Light Roof (Asphalt Shingle)
• Under Roof Joists: R-6.0 insul.
• Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofCasita Zone
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 19
0.052
Roofing: Light Roof (Asphalt Shingle)
• Under Roof Joists: R-6.0 insul.
• Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roof2nd Floor
Attic Roofs
Wood Framed Ceiling
in. O.0
R 19
0.052
Roofing: Light Roof (Asphalt Shingle)
• Floor Surface: Carpeted
Floors Over
R 19 in 5-1/2 in.
Floor Deck: Wood Siding/sheathing/decking
R-19 Floor
Crawlspace
Wood Framed Floor
2x6 @ 16 in. O.C.
cavity (R-18)
0.050
Cavity/Frame: R-19 in 5-1/2 in. (R-18) /2x6
Registration Number: 218-P010323021A-000-000-000000a0000 Registration Date/Time: 2018-12-06 09:27:42 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Tonkin Res Calculation Date/Time: 09:01, Thu, Dec 06, 2018
Calculation Description: Title 24 Analysis
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribdl6x
CF1 R-PRF-01
Page 11 of 15
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Slab -on -Grade
Master Suite
1361
112
None
0.8
No
Slab -on -Grade 2
Living Space
3292
278
None
0.8
No
Slab -on -Grade 3
Bdrms 2
345
44
None
0.8
No
Slab -on -Grade 4
Casita Zone
1271
158
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
n/a
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Standard
DHW Heater 1 (2)
2
.0%
WATER HEATERS
01
02
03
04
05
06
I 07
' 08
09
10
11
12
Name
Heater
Element
Type
Tank Type
Number
of Units
Tank
Volume
(gal)
Uniform Energy
Factor / Energy
Factor / Efficiency
Input Rating /
Pilot /
Thermal
Efficiency
Tank
Insulation
R-value
(Int/Ext)
Standby
Loss /
Recovery
Eff
First Hour
Rating /
Flow Rate
NEEA Heat Pump
Brand / Model /
Other
Tank Location
or Ambient
Condition
DHW Heater 1
Gas
I Large Storage
2
100
0.8 TE
85,000 Btu/hr
R-0/R-0
0.03
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
I 06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC-Masterl
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC-Great/Living/Kit. /D2
Other Heating and Cooling
System
Heating Component 2
Cooling Component 2
HVAC Fan 2
Air Distribution System 2
HVAC-Casita3
Other Heating and Cooling
System
Heating Component 3
Cooling Component 3
HVAC Fan 3
Air Distribution System 3
HVAC-2nd Floor4
Other Heating and Cooling
System
Heating Component 4
Cooling Component 4
HVAC Fan 4
Air Distribution System 4
Registration Number: 218-Po10323021A-000-000-0000000-0000 Registration Date/Time: 2018-12-06 09:27:42 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Tonkin Res. Calculation Date/Time: 09:01, Thu, Dec 06, 2018
Calculation Description: Title 24 Analysis
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribd16x
CFI R-PRF-01
Page 12 of 15
HVAC - HEATING UNIT TYPES
01
02
03
04
Name
System Type
Number of Units
Efficiency
Heating Component 1
CntrlFurnace
1
80 AFUE
Heating Component 2
CntrlFurnace
3
80 AFUE
Heating Component 3
CntrlFurnace
1
80 AFUE
Heating Component 4
CntrlFurnace
1
80 AFUE
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
08
Name
System Type
Number of Units
Efficiency
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
1
13
16
Not Zonal
Single Speed
Cooling Component
1-hers-cool
Cooling Component 2
SplitAirCond
3
13
16
Not Zonal
Single Speed
Cooling Component
2-hers-cool
Cooling Component 3
SplitAirCond
1
13
16
Not Zonal
Single Speed
Cooling Component
3-hers-cool
Cooling Component 4
SplitAirCond
I 1
13
16
Not Zonal
Single Speed
Cooling Component
4-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
Cooling Component 2-hers-cool
Required
350
Required
Required
Required
Cooling Component 3-hers-cool
Required
350
Required
Required
Required
Cooling Component 4-hers-cool
Required
350
Required
Required
Required
Registration Number: 218-P010323021A-000-000-0000000-0000 Registration Date/Time: 2018-12-06 09:27:42 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Tonkin Res Calculation Date/Time: 09:01, Thu, Dec 06, 2018
Calculation Description: Title 24 Analysis
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18 ribdl6x
CF1 R-PRF-01
Page 13 of 15
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation
R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Specified Lower Leakage
Target
8
Attic
None
Air Distribution System
1-hers-dist
Air Distribution System 2
DuctsAttic
Specified Lower Leakage
Target
8
Attic
None
Air Distribution System
2-hers-dist
Air Distribution System 3
DuctsAttic
Specified Lower Leakage
Target
8
Attic
None
Air Distribution System
3-hers-dist
Air Distribution System 4
DuctsAttic
I Specified Lower Leakage
Target
8
Attic
None
Air Distribution System
4-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-list
Required !
5.0
Not Required
Not Required
Not Required
Not Required
Required
Air Distribution System 2-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
Required
Air Distribution System 3-hers-list
Required
5.0
Not Required
Not Required
Not Required
I Not Required
Required
Air Distribution System 4-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
Required
HVAC-FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.53
HVAC Fan 1-hers-fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.53
HVAC Fan 2-hers-fan
HVAC Fan 3
Single Speed PSC Furnace Fan
0.53
HVAC Fan 3-hers-fan
HVAC Fan 4
Single Speed PSC Furnace Fan
0.53
HVAC Fan 4-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.53
HVAC Fan 2-hers-fan
Required
0.53
HVAC Fan 3-hers-fan
Required
0.53
HVAC Fan 4-hers-fan
Required
0.53
Registration Number: 216-Po10323021A-000-000-0000000-0000 Registration DateTFime: 2016-12-06 09:27:42 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Tonkin Res. Calculation Date/Time: 09:01, Thu, Dec 06, 2018
Calculation Description: Title 24 Analysis
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribd16x
CF1 R-PRF-01
Page 14 of 15
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
125
0.25
Default
0
Required
Registration Number. 218-P010323021A-000-000-0000000-0000 Registration DateMme: 2018-12-06 09:27:42 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Tonkin Res. Calculation Date/Time: 09:01, Thu, Dec 06, 2018
Calculation Description: Title 24 Analysis
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribdl6x
CF1 R-PRF-01
Page 15 of 15
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tc�,5�a?r
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2018-12-06 09:27:42
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Tim Scott
Company:
Date Signed:
Scott Design and Title 24, Inc.
2018-12-06 09:27:42
Address:
License:
77085 Michigan Drive
NA
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document and in no way implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 218-P010323021A-000-000-0000000-0000 Registration Date/Time: 2018-12-06 09:27:42
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149
Easy to Verify
at CaICERTS.com
HERS Provider: CaICERTS inc
Report Generated at: 2018-12-06 09:03:45
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Tonkin Residence
Lot 31 & 32C, The Hidea
La Quinta, CA 92253
�$I I r +fit- LA QUINTA
BUILDING DIVISION
F►EVIEWED FOR
CODE
COMPLIANCE
y
�6 & tA1-E n RY t II"
Project Designer:
Stracts, Inc
550 S. Oleander
Palm Springs„ CA 92264
(760) 636-8951)� Ar //%/Jq
Report Prepared by:
Tim Scott
Scott Design and Title 24, Inc,
74-818 Velie Way, Suite #8
Palm Desert, CA 92260
(760) 200-4780
653-0 �q VIA S Wop\f �
Job Number: RECEIVED
DEC 2 0 n18
Date: CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
12/6/2018
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards.
This program developed by EnergySoft Software — www.energysoft.com.
G��y
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF-1 R-PRF-01-E Certificate of Compliance 3
Form RMS-1 Residential Measures Summary 18
Form MF-1 R Mandatory Measures Summary 20
HVAC System Heating and Cooling Loads Summary 24
Zone Load Summary 28
Room Load Summary 32
Room Heating Peak Loads 36
Room Cooling Peak Loads 41
CERT' 1TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: Tonkin Res.
Calculation Description: Title 24 Analysis
'HOD
Calculation Date/Time: 09:01, Thu, Dec 06, 2018
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribdl6x
CF 'RF-01
Page 1 of 15
GENERAL INFORMATION
01
Project Name
Tonkin Res.
02
Calculation Description
Title 24 Analysis
03
Project Location
Lot 31 & 32C, The Hideaway
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.3.1 (1149)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.2
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
135
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ftZ)
7283
15
Number of Zones
15
16
Slab Area (ftZ)
6269
17
Number of Stories
1
18
Addition Cond. Floor Area(ft2)
n/a
19
Natural Gas Available
Yes
20
Addition Slab Area (ftZ)
n/a
21
Glazing Percentage (%)
34.2%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04
05 1
06
07
08
Energy Use (kTDV/ftZ-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
3.04
5.56
-2.52
-82.9%
Space Cooling
82.99
73.29
9.70
11.7%
IAQ Ventilation
0.79
0.79
0.00
0.0%
Water Heating
2.25
9.04
-6.79
-301.8%
Photovoltaic Offset
---
0.00
0.00
—
Compliance Energy Total
89.07
88.68
0.39
0.4%
Registration Number: 218-Po10323021A-000-000-0000000-0000 Registration Date/Time: 2018-12-06 09:27:42 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERT' JE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE -HOD CF 'RF-01
Project Name: Tonkin Res. Calculation Date/Time: 09:01, Thu, Dec 06, 2018 Page 2 of 15
Calculation Description: Title 24 Analysis Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribdl6x
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency
EDR of Proposed Efficiency
EDR Value of Proposed PV + Battery
Final Proposed EDR
47.9
47.7
0.0
47.7
❑
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV)
renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified.
Notes:
• Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering NEM) rules
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
Provided in the building components tables below.
Building -level Verifications:
• High quality insulation installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Verified Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Low -leakage Air Handling Unit
Domestic Hot Water System Verifications:
-- None --
Registration Number: 218-Po10323021A-000-000-0000000-0000 Registration Date/Time: 2018-12-06 09:27:42 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERTI TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: Tonkin Res.
Calculation Description: Title 24 Analysis
'HOD
Calculation Date/Time: 09:01, Thu, Dec 06, 2018
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribdl6x
CF 'RF-01
Page 3 of 15
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Tonkin Res.
7283
1
6
5
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Master Suite
Conditioned
HVAC-Master1
1361
10
DHW Sys 1
n/a
Living Space
Conditioned
HVAC-Great/Living/Kit. /D2
3292
13.4
DHW Sys 1
n/a
Bdrms 2
Conditioned
HVAC-Great/Living/Kit. /D2
345
10
DHW Sys 1
n/a
Casita Zone
Conditioned
HVAC-Casita3
1271
10.9
DHW Sys 1
n/a
2nd Floor
Conditioned
HVAC-2nd Floor4
1014
9.5
DHW Sys 1
n/a
Registration Number: 218-P010323021A-000-000-0000000-0000 Registration Daterflime: 2018-12-06 09:27:42 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERTr 1TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE -HOD
Project Name: Tonkin Res. Calculation Date/Time: 09:01, Thu, Dec 06, 2018
Calculation Description: Title 24 Analysis
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribd16x
CF 'RF-01
Page 4 of 15
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ft)
Tilt (deg)
75d Wall
Master Suite
R-21 Wall
75
- specify -
290
18.9
90
165d Wall
Master Suite
R-21 Wall
165
- specify -
350
0
90
255d Wall
Master Suite
R-21 Wall
255
- specify -
540
106.3
90
345d Wall
Master Suite
R-21 Wall
345
- specify -
280
104
90
Interior Surface
Master Suite»Living Space
R-0 Interior Surface
n/a
n/a
530
0
n/a
Roof
Master Suite
R-38 Roof Attic R19 High
n/a
n/a
1361
n/a
n/a
NE Wall
Living Space
R-21 Wall
45
Right
633
195
90
SE Wall
Living Space
R-21 Wall
135
Front
1007
405
90
165d Wall 2
Living Space
R-21 Wall
165
specify -
140
80
90
SW Wall
Living Space
R-21 Wall
225
Left
608
98
90
NW Wall
Living Space
R-21 Wall
315
Back
970
530
90
345d Wall 2
Living Space
R-21 Wall
165
- specify -
80
32
90
Interior Surface 2
Living Space»Master Suite
R-0 Interior Surface
n/a
n/a
530
0
n/a
Interior Surface 3
Living Space»Bdrms 2
R-0 Interior Surface
n/a
n/a
360
0
n/a
Roof 2
Living Space
R-38 Roof Attic R19 High
n/a
n/a
3292
n/a
n/a
NE Wall 2
Bdrms 2
R-21 Wall
45
Right
195
74
90
SE Wall 2
Bdrms 2
R-21 Wall
135
Front
175
0
90
NW Wall 2
Bdrms 2
R-21 Wall
315
Back
70
0
90
Interior Surface 4
Bdrms 2»Living Space
R-0 Interior Surface
n/a
n/a
360
0
n/a
Roof 3
Bdrms 2
R-38 Roof Attic R19 High
n/a
n/a
345
n/a
n/a
75d Wall 2
Casita Zone
R-21 Wall
75
specify -
429
99.1
90
165d Wall 3
Casita Zone
R-21 Wall
165
specify -
466
214.4
90
255d Wall 2
Casita Zone
R-21 Wall
255
specify -
380
46.5
90
345d Wall 3
Casita Zone
R-21 Wall
345
- specify -
507
162.4
90
Interior Surface 5
Casita Zone»Living Space
R-0 Interior Surface
n/a
n/a
530
0
n/a
Roof 4
Casita Zone
R-38 Roof Attic R19 High
n/a
n/a
1271
n/a
n/a
75d Wall 3
2nd Floor
R-21 Wall
75
- specify -
428
76.3
90
165d Wall 4
2nd Floor
R-21 Wall
165
- specify -
276
106
90
255d Wall 3
2nd Floor
R-21 Wall
255
- specify -
428
49.6
90
345d Wall 4
2nd Floor
R-21 Wall
345
- specify -
276
92
90
Registration Number: 218-Po10323021A-000-000-0000000-0000 Registration DateMme: 2018-12-06 09:27:42 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERTI LTE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: Tonkin Res.
Calculation Description: Title 24 Analysis
C
Calculation Date/Time: 09:01, Thu, Dec06, 2018
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribd16x
CF ')RF-01
Page 5 of 15
Interior Surface 6
2nd Floor —Living Space
R-0 Interior Surface
n/a
n/a
530
0
n/a
Roof 5
2nd Floor
R-38 Roof Attic R19 High
n/a
n/a
1014
n/a
n/a
Raised Floor
2nd Floor
R-19 Floor
n/a
n/a
371
n/a
n/a
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Master Suite
Attic RoofMaster Suite
Unventilated
3
0.1
0.85
No
No
Attic Living Space
Attic RoofLiving Space
Unventilated
3
0.1
0.85
No
No
Attic Bdrms 2
Attic RoofBdrms 2
Unventilated
3
0.1
0.85
No
No
Attic Casita Zone
Attic RoofCasita Zone
Unventilated
3
0.1
0.85
No
No
Attic 2nd Floor
Attic Roof2nd Floor
Unventilated
3
0.1
0.85
No
No
Registration Number: 218-P010323021A-000-000-0000000-0000 Registration DateRme: 2018-12-06 09:27:42 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERTI ,TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 'HOD
Project Name: Tonkin Res. Calculation Date/Time: 09:01, Thu, Dec 06, 2018
Calculation Description: Title 24 Analysis Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribd16x
CF 'RF-01
Page 6 of 15
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft)
U-factor
SHGC
Exterior Shading
X
Window
75d Wall (- specify -75)
-
1
6.3
0.25
0.16
Insect Screen (default)
Y
Window
75d Wall (- specify --75)
-
-
1
6.3
0.25
0.16
Insect Screen (default)
Z
Window
75d Wall (- specify -75)
-
-
1
6.3
0.25
0.16
Insect Screen (default)
M
Window
255d Wall (- specify -255)
-
-
1
6.3
0.25
0.16
Insect Screen (default)
16
Window
255d Wall (- specify -255)
10.0
8.0
1
80.0
0.41
0.21
Insect Screen (default)
15
Window
255d Wall (- specify -255)
-
-
1
20.0
0.39
0.18
Insect Screen (default)
14
Window
345d Wall (- specify -345)
-
1
104.0
0.41
0.21
Insect Screen (default)
K
Window
NE Wall (Right-45)
--
1
130.0
0.25
0.16
Insect Screen (default)
9
Window
NE Wall (Right-45)
-
-
1
40.0
0.39
0.18
Insect Screen (default)
J
Window
NE Wall (Right-45)
-
-
1
25.0
0.25
0.16
Insect Screen (default)
2
Window
SE Wall (Front-135)
12.5
8.0
1
100.0
0.41
0.21
Insect Screen (default)
B
Window
SE Wall (Front-135)
6.5
10.0
1
65.0
0.25
0.16
Insect Screen (default)
1
Window
SE Wall (Front-135)
8.0
10.0
1
80.0
0.25
0.16
Insect Screen (default)
A
Window
SE Wall (Front-135)
6.5
10.0
1
65.0
0.25
0.16
Insect Screen (default)
AA
Window
SE Wall (Front-135)
-
-
1 1
80.0
0.25
0.16
Insect Screen (default)
CC
Window
SE Wall (Front-135)
-
-
1
7.5
0.25
0.16
Insect Screen (default)
DID
Window
SE Wall (Front-135)
-
1
7.5
0.25
0.16
Insect Screen (default)
AA 2
Window
165d Wall 2 (- specify --165)
-
1
80.0
0.25
0.16
Insect Screen (default)
D
Window
SW Wall (Left-225)
-
-
1
16.0
0.25
0.16
Insect Screen (default)
C
Window
SW Wall (Left-225)
5.0
8.0
1
40.0
0.25
1 0.16
Insect Screen (default)
BB
Window
SW Wall (Left-225)
-
-
1
10.0
0.25
0.16
1 Insect Screen (default)
BB 2
Window
SW Wall (Left-225)
-
-
1
11.0
0.25
0.16
Insect Screen (default)
BB 3
Window
SW Wall (Left-225)
-
-
1
11.0
0.25
0.16
Insect Screen (default)
BB 4
Window
SW Wall (Left-225)
----
-
1
10.0
0.25
0.16
Insect Screen (default)
13
Window
NW Wall (Back-315)
30.0
10.0
1
300.0
0.41
0.21
Insect Screen (default)
12
Window
NW Wall (Back-315)
5.0
10.0
1
50.0
0.41
0.21
Insect Screen (default)
11
Window
NW Wall (Back-315)
1
1 150.0
0.41
0.21
Insect Screen (default)
EE
Window
NW Wall (Back-315)
-
1
7.5
0.25
0.16
Insect Screen (default)
FF
Window
NW Wall (Back-315)
----
-
1
7.5
0.25
0.16
Insect Screen (default)
Registration Number: 218-Po10323021A-000-000-0000000-0000 Registration Date/Time: 2018-12-06 09:27:42 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-1 1302018-1149 Report Generated at: 2018-12-06 09:03:45
CERTI ,TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: Tonkin Res.
Calculation Description: Title 24 Analysis
'HOD
Calculation Date/Time: 09:01, Thu, Dec 06, 2018
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribd16x
CF 'RF-01
Page 7 of 15
GG
Window
NW Wall (Back-315)
--
-
1
7.5
0.25
0.16
Insect Screen (default)
HH
Window
NW Wall (Back-315)
---
1
7.5
0.25
0.16
Insect Screen (default)
L
Window
345d Wall 2 (- specify -165)
4.0
8.0
1
32.0
0.25
0.16
Insect Screen (default)
8
Window
NE Wall 2 (Right-45)
----
--
1
68.0
0.41
0.21
Insect Screen (default)
H
Window
NE Wall 2 (Right-45)
-
--
1
6.0
0.25
0.16
Insect Screen (default)
W
Window
75d Wall 2 (- specify --75)
2.5
3.0
1
7.5
0.25
0.16
Insect Screen (default)
19
Window
75d Wall 2 (- specify --75)
2.5
8.0
1
20.0
0.39
0.18
Insect Screen (default)
U
Window
75d Wall 2 (- specify -75)
-
-
1
44.0
0.25
0.16
Insect Screen (default)
NN
Window
75d Wall 2 (- specify --75)
-
-
1
4.6
0.25
0.16
Insect Screen (default)
PP(
Window
75d Wall 2 (- specify --75)
•----
-
1
4.6
0.25
0.16
Insect Screen (default)
QQ
Window
75d Wall 2 (- specify --75)
-
--•--
1
4.6
0.25
0.16
Insect Screen (default)
RR
Window
75d Wall 2 (- specify --75)
---
-
1
4.6
0.25
0.16
Insect Screen (default)
SS
Window
75d Wall 2 (- specify --75)
-
--
1
4.6
0.25
0.16
Insect Screen (default)
TT
Window
75d Wall 2 (- specify --75)
---
1
4.6
0.25
0.16
Insect Screen (default)
U 2
Window
165d Wall 3 (- specify --165)
-
-
1
154.0
0.25
0.16
Insect Screen (default)
T
Window
165d Wall 3 (- specify -165)
-
1
6.0
0.25
0.16
Insect Screen (default)
S
Window
165d Wall 3 (- specify --165)
-
1
6.0
0.25
0.16
Insect Screen (default)
R
Window
165d Wall 3 (- specify --165)
-
-
1
1 30.0
0.25
0.16
1 Insect Screen (default)
AF
Window
165d Wall 3 (- specify --165)
-
-
1
4.6
0.25
0.16
Insect Screen (default)
AG
Window
165d Wall 3 (- specify -165)
-
1
4.6
0.25
0.16
Insect Screen (default)
AH
Window
165d Wall 3 (- specify -165)
-
1
4.6
0.25
0.16
Insect Screen (default)
AJ
Window
165d Wall 3 (- specify -165)
-
-
1
4.6
0.25
0.16
Insect Screen (default)
Q
Window
255d Wall 2 (- specify --255)
--
-
1
6.3
0.25
0.16
Insect Screen (default)
P
Window
255d Wall 2 (- specify -255)
1
6.3
0.25
0.16
Insect Screen (default)
N
Window
255d Wall 2 (- specify --255)
-
-
1
6.3
0.25
0.16
Insect Screen (default)
YY
Window
255d Wall 2 (- specify --255)
-
1
4.6
0.25
0.16
Insect Screen (default)
ZZ
Window
255d Wall 2 (- specify --255)
-
1
4.6
0.25
0.16
Insect Screen (default)
AB
Window
255d Wall 2 (- specify --255)
-
1
4.6
0.25
0.16
Insect Screen (default)
AC
Window
255d Wall 2 (- specify --255)
-
-
1
4.6
0.25
0.16
Insect Screen (default)
AD
Window
255d Wall 2 (- specify --255)
-
1
4.6
0.25
0.16
Insect Screen (default)
AE
Window
255d Wall 2 (- specify --255)
-
1
4.6
0.25
0.16
Insect Screen (default)
142
Window
345d Wall 3 (- specify --345)
-
-
1
104.0
0.41
0.21
Insect Screen (default)
V
Window
345d Wall 3 (- specify --345)
-
-
1
16.0
0.25
0.16
Insect Screen (default)
Registration Number: 218-Po10323021A-000-000-0000000-0000 Registration Date/Time: 2018-12-06 09:27:42 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERV ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: Tonkin Res.
Calculation Description: Title 24 Analysis
'HOD
Calculation Date/Time: 09:01, Thu, Dec 06, 2018
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribd16x
CF 'RF-01
Page 8 of 15
JJ
Window
345d Wall 3 (- specify --345)
-
-
1
6.0
0.25
0.16
Insect Screen (default)
KK
Window
345d Wall 3 (- specify -345)
1
6.0
0.25
0.16
Insect Screen (default)
LL
Window
345d Wall 3 (- specify --345)
1
6.0
0.25
0.16
Insect Screen (default)
MM
Window
345d Wall 3 (- specify --345)
1
6.0
0.25
0.16
Insect Screen (default)
UU
Window
345d Wall 3 (- specify --345)
-
-
1
4.6
0.25
0.16
1 Insect Screen (default)
VV
Window
345d Wall 3 (- specify --345)
-
-
1
4.6
0.25
0.16
Insect Screen (default)
WW
Window
345d Wall 3 (- specify --345)
1
4.6
0.25
0.16
Insect Screen (default)
XX
Window
345d Wall 3 (- specify --345)
-
1
4.6
0.25
0.16
Insect Screen (default)
AL
Window
75d Wall 3 (- specify --75)
1
25.0
0.25
0.16
Insect Screen (default)
52
Window
75d Wall 3 (- specify --75)
-
-
1
40.0
0.39
0.18
Insect Screen (default)
AL 2
Window
75d Wall 3 (- specify --75)
1
11.3
0.25
0.16
Insect Screen (default)
AM
Window
165d Wall 4 (- specify --165)
--
-
1
30.0
0.25
0.16
Insect Screen (default)
51
Window
165d Wall 4 (- specify -165)
9.5
8.0
1
76.0
0.39
0.18
Insect Screen (default)
AV
Window
255d Wall 3 (- specify --255)
-
-
1
11.3
0.25
0.16
Insect Screen (default)
AT
Window
255d Wall 3 ( specify --255)
-
1
11.3
0.25
0.16
Insect Screen (default)
AS
Window
255d Wall 3 (- specify --255)
-
-,
1
6.0
0.25
0.16
Insect Screen (default)
AR
Window
255d Wall 3 (- specify --255)
-
-
1
6.0
0.25
0.16
Insect Screen (default)
AQ
Window
255d Wall 3 (- specify -255)
-
1
5.0
0.25
0.16
1 Insect Screen (default)
AP
Window
255d Wall 3 (- specify --255)
-
-
1
5.0
0.25
0.16
Insect Screen (default)
AN
Window
255d Wall 3 (- specify --255)
---
-
1
5.0
0.25
0.16
Insect Screen (default)
50
Window
345d Wall 4 (- specify --345)
8.5
8.0
1
68.0
0.39
0.18
Insect Screen (default)
49
Window
345d Wall 4 (- specify --345)
3.0
8.0
1
24.0
0.39
0.18
Insect Screen (default)
Registration Number: 218-P010323021A-000-000-0000000-0000 Registration DateMme: 2018-12-06 09:27:42 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERTI .TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: Tonkin Res.
Calculation Description: Title 24 Analysis
HOD
Calculation Date/Time: 09:01, Thu, Dec 06, 2018
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribd16x
CF IRF-01
Page 9 of 15
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
16
8
0.1
8
8
0
10
0
0
0
0
0
0
0
2
10
0.1
10
10
0
0
0
0
0
0
0
0
0
B
10
0.1
10
10
0
0
0
0
0
0
0
0
0
1
10
0.1
10
10
0
0
0
0
0
0
0
0
0
A
10
0.1
10
10
0
0
0
0
0
0
0
0
0
C
12
0.1
12
12
0
0
0
0
0
0
0
0
0
13
16
0.1
16
16
0
0
0
0
0
0
0
0
0
12
14
0.1
14
14
0
0
0
0
0
0
0
0
0
L
20
0.1
20
20
0
0
0
0
0
0
0
0
0
W
8
0.1
8
8
0
0
0
0
0
0
0
0
0
19
8
0.1
8
8
0
0
0
0
0
0
0
0
0
51
10
0.1
10
10
0
0
0
0
0
0
0
0
0
50
16
0.1
16
16
0
0
0
0
0
0
0
0
0
49
16
0.1
16
16
0
0
0
0
0
0
0
0
0
Registration Number: 218-Po10323021A-000-000-0000000-0000 Registration DateMme: 2018-12-06 09:27:42 HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERT' JE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: Tonkin Res.
Calculation Description: Title 24 Analysis
'HOD
Calculation DatelTime: 09:01, Thu, Dec 06, 2018
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribdl6x
Cf 'RF-01
Page 10 of 15
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-factor
Assembly Layers
Under Roof Joists: R-6.0 insul.
Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofMaster Suite
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 19
0.052
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic R19 High
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Ceiling Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
R-21 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.069
Exterior Finish: 3 Coat Stucco
• Inside Finish: Gypsum Board
• Cavity/Frame: no insul. /2x4
R-0 Interior Surface
Interior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
none
0.277
Other Side Finish: Gypsum Board
Under Roof Joists: R-6.0 insul.
Cavity/Frame: R-13.0 /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck., Wood Siding/sheathing/decking
Attic RoofLiving Space
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 19
0.052
Roofing: Light Roof (Asphalt Shingle)
• Under Roof Joists: R-6.0 insul.
• Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofBdrms 2
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 19
0.052
Roofing: Light Roof (Asphalt Shingle)
• Under Roof Joists: R-6.0 insul.
• Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofCasita Zone
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 19
0.052
Roofing: Light Roof (Asphalt Shingle)
• Under Roof Joists: R-6.0 insul.
• Cavity/Frame: R-13.0 /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck., Wood Siding/sheathing/decking
Attic Roof2nd Floor
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 19
0.052
Roofing., Light Roof (Asphalt Shingle)
• Floor Surface: Carpeted
Floors Over
R 19 in 5-1/2 in.
Floor Deck: Wood Siding/sheathing/decking
R-19 Floor
Crawlspace
Wood Framed Floor
2x6 @ 16 in. O.C.
cavity (R-18)
0.050
Cavity/Frame: R- 19 in 5-1/2 in. (R-18) /2x6
Registration Number: 218-PO10323021A-000-000-0000000-0000 Registration Date/Time: 2018-12-06 09:27:42 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERT' ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 'HOD
CF 'RF-01
Project Name: Tonkin Res.
Calculation Description: Title 24 Analysis
Calculation DatelTime: 09:01, Thu, Dec 06, 2018 Page 11 of 15
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribdl6x
SLAB FLOORS
01
02
03
04
I 05
06
07
Name
Zone
Area (ft)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Slab -on -Grade
Master Suite
1361
112
None
0.8
No
Slab -on -Grade 2
Living Space
3292
278
None
0.8
No
Slab -on -Grade 3
Bdrms 2
345
44
None
0.8
No
Slab -on -Grade 4
Casita Zone
1271
158
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03 04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage CFM50
Required
Not Required
Not Required n/a
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Standard
DHW Heater 1 (2)
2
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11 1
12
Input Rating I
Tank
Standby
Heater
Tank
Uniform Energy
Pilot /
Insulation
Loss /
First Hour
NEEA Heat Pump
Tank Location
Element
Number
Volume
Factor / Energy
Thermal
R-value
Recovery
Rating /
Brand / Model /
or Ambient
Name
Type
Tank Type
of Units
(gal)
Factor / Efficiency
Efficiency
(Int/Ext)
Eff
Flow Rate
Other
Condition
DHW Heater 1
Gas
Large Storage
2
100
1 0.8 TE
85,000 Btu/hr
R-0/R-0
0.03
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC-Masterl
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC-Great/Living/Kit. /D2
Other Heating and Cooling
System
Heating Component 2
Cooling Component 2
HVAC Fan 2
Air Distribution System 2
HVAC-Casita3
Other Heating and Cooling
System
Heating Component 3
Cooling Component 3
HVAC Fan 3
Air Distribution System 3
HVAC-2nd Floor4
Other Heating and Cooling
System
Heating Component 4
Cooling Component 4
HVAC Fan 4
Air Distribution System 4
Registration Number: 218-Po10323021A-000-o00-0000000-0000 Registration Date/Time: 2018-12-06 09:27:42 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERT' \TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE -HOD
Project Name: Tonkin Res. Calculation Date/Time: 09:01, Thu, Dec 06, 2018
Calculation Description: Title 24 Analysis
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribdl6x
Cf 'RF-01
Page 12 of 15
HVAC - HEATING UNIT TYPES
01
02
03
04
Name
System Type
Number of Units
Efficiency
Heating Component 1
CntrlFumace
1
80 AFUE
Heating Component 2
CntrlFurace
3
80 AFUE
Heating Component 3
CntrlFumace
1
80 AFUE
Heating Component 4
CntrlFumace
1
80 AFUE
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
08
Efficiency
Name
System Type
Number of Units
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
1
13
16
Not Zonal
Single Speed
Cooling Component
1-hers-cool
Cooling Component 2
SplitAirCond
3
13
16
Not Zonal
Single Speed
Cooling Component
2-hers-cool
Cooling Component 3
SplitAirCond
1
13
16
Not Zonal
Single Speed
Cooling Component
3-hers-cool
Cooling Component 4
SplitAirCond
1
13
16
Not Zonal
Single Speed
Cooling Component
4-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
Cooling Component 2-hers-cool
Required
350
Required
Required
Required
Cooling Component 3-hers-cool
Required
350
Required
Required
Required
Cooling Component 4-hers-cool
Required
350
Required
Required
Required
Registration Number: 218-Po10323021A-000-000-0000000-0000 Registration DateRme: 2018-12-06 09:27:42 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERT' 1TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: Tonkin Res.
Calculation Description: Title 24 Analysis
.emu
Calculation Date/Time: 09:01, Thu, Dec 06, 2018
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribd16x
Cf 'RF-01
Page 13 of 15
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Specified Lower Leakage
8
Attic
None
Air Distribution System
Target
1-hers-dist
Air Distribution System 2
DuctsAttic
Specified Lower Leakage
8
Attic
None
Air Distribution System
Target
2-hers-dist
Air Distribution System 3
DuctsAttic
Specified Lower Leakage
8
Attic
None
Air Distribution System
Target
3-hers-dist
Air Distribution System 4
DuctsAttic
Specified Lower Leakage
8
Attic
None
Air Distribution System
Target
4-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
Required
Air Distribution System 2-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
Required
Air Distribution System 3-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
Required
Air Distribution System 4-hers-list
Required
5.0
Not Required
Not Required
Not Required
Not Required
Required
HVAC-FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.53
HVAC Fan 1-hers-fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.53
HVAC Fan 2-hers-fan
HVAC Fan 3
Single Speed PSC Furnace Fan
0.53
HVAC Fan 3-hers-fan
HVAC Fan 4
Single Speed PSC Furnace Fan
0.53
HVAC Fan 4-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.53
HVAC Fan 2-hers-fan
Required
0.53
HVAC Fan 3-hers-fan
Required
0.53
HVAC Fan 4-hers-fan
Required
0.53
Registration Number: 218-P010323021A-000-000-0000000-0000 Registration Date/Time: 2018-12-06 09:27:42 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERTI iTE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: Tonkin Res.
Calculation Description: Title 24 Analysis
'HOD
Calculation Daterrime: 09:01, Thu, Dec 06, 2018
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribdl6x
CF 'RF-01
Page 14 of 15
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
125
0.25
Default
0
Required
Registration Number: 218-P010323021A-000-000-0000000-0000 Registration Date/Time: 2018-12-06 09:27:42 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance ReportVersion - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
CERT! ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 'HOD
Project Name: Tonkin Res.
Calculation Description: Title 24 Analysis
Calculation Date/Time: 09:01, Thu, Dec 06, 2018
Input File Name: Hideaway 31_32C-Tonkin-Stracts-18.ribd16x
CF ')RF-01
Page 15 of 15
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2018-12-06 09:27:42
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature
Tim Scott
Company:
Date Signed:
Scott Design and Title 24, Inc.
2018-12-06 09:27:42
Address:
License:
77085 Michigan Drive
NA
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration
Provider responsibility for the accuracy of the information.
0
Easy to Verify
at CaICERTS.com
Registration Number: 218-P010323021A-000-000-0000000-0000 Registration Date/Tme: 2018-12-06 09:27:42 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-11302018-1149 Report Generated at: 2018-12-06 09:03:45
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Tonkin Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
121612018
Project Address
Lot 31 & 32C, The Hideaway
La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
7,283
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
Cavity ft)
Special Features Status
Roof Wood Framed Attic
R 38 7,283
Add=R-19.0
New
Wall Wood Framed
R 21 6,039
New
Slab Unheated Slab -on -Grade
no insulation 6,269
Perim = 592'
New
Demising Wood Framed
no insulation 2,840
New
Floor Wood Framed w/Crawl Space R 19 371
New
FENESTRATION Total Area: 2,490 Glazing Percents e: 34•2
Orientation Area ft2 U-Fac SHGC Overhang Sidefins
NewfAltered Average U-Factor: 0.33
Exterior Shades Status
Right (E) 126.8
0.250
0.16 none
none
Bug Screen New
Left (W) 102.4
0.250
0.16 none
none
Bug Screen New
Left (W) 60.0
0.410
0.21 8.0
none
Bug Screen New
Left (W) 20.0
0,390
0.18 none
none
Bug Screen New
Rear (N) 104.0
0.410
0.21 10.0
none
Bug Screen New
Right (NE) 161.0
0.250
0.16 none
none
Bug Screen New
Right (NE) 40.0
0.390
0.18 none
none
Bug Screen New
Front (SE) 100.0
0.410
0.21 10.0
none
Bug Screen New
Front (SE) 210.0
0.250
0.16 10.0
none
Bug Screen New
Front (SE) 95.0
0.250
0.16 none
none
Bug Screen New
Front (S) 324.4
0.250
0.16 none
none
Bug Screen New
Left (SW) 58.0
0.250
0.16 none
none
Bug Screen New
Left (SW) 40.0
0.250
0.16 12.0
none
Bug Screen New
Rear (NW) 300.0
0.410
0.21 16.0
none
Bug Screen New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling
Min. Eff
Thermostat Status
1 Central Furnace
80% AFUE
Split Air Conditioner
16.0 SEER
Setback
New
3 Central Furnace
80% AFUE
Split Air Conditioner
16.0 SEER
Setback
New
1 Central Furnace
80% AFUE
Split Air Conditioner
16.0 SEER
Setback
New
HVAC DISTRIBUTION
Location Heating
Cooling Duct Location
Duct
R-Value Status
HVAC-Master Ducted
HVAC-Great/Living/Kit. /Dir Ducted
Ducted Attic
Ducted Attic
8.0 New
8.0 New
HVAC-Casita Ducted
WATER HEATING
Qty. Type
Ducted Attic
Gallons Min. Eff
8.0 New
Distribution Status
2 Large Storage Gas
100
0.80
Standard
New
EneogyPro 7.2 by EnerqySoft User Number: 6712
ID: Pape 18 of 51
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Tonkin Residence
Building Type
1
m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
121612018
Project Address
Lot 31 & 32C, The Hideaway La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area Addition
7,283 n/a
# of Units
1
INSULATION
Construction Type
Cavity
Area
(ft) Special Features
Status
FENESTRATION
Orientation Area ft2
Total Area: 2•490 34�
U-Fac SHGC Overhang Sidefins
wMit
Exterior Shades
0.33.P
Status
Rear (NW) 50.0
0.410
0.21 14.0
none
Bug Screen
New
Rear (NW) 150.0
0.410
0.21 none
none
Bug Screen
New
Rear (NW) 30.0
0.250
0.16 none
none
Bug Screen
New
Front(S) 3ZO
0.250
0.16 20.0
none
Bug Screen
New
Right (NE) 68.0
0.410
0.21 none
none
Bug Screen
New
Right (E) 7.5
0.250
0.16 8.0
none
Bug Screen
New
Right (E) 20.0
0.390
0.18 8.0
none
Bug Screen
New
Rear (N) 104.0
0.410
0.21 none
none
Bug Screen
New
Rear (N) 58.4
0.250
0.16 none
none
Bug Screen
New
Right (E) 40.0
0.390
0.18 none
none
Bug Screen
New
Front (S) 76.0
0.390
0.18 10.0
none
Bug Screen
New
Rear (N) 92.0
0.390
0.18 16.0
none
Bug Screen
New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling
Min. Eff
Thermostat Status
1 Central Furnace 80% AFUE
HVAC DISTRIBUTION
Location Heating
Split Air Conditioner 16.0 SEER
Cooling Duct Location
Setback New
Duct
R-Value Status
HVAC-2nd Floor Ducted
WATER HEATING
Qty. Type
Ducted Attic 8.0 New
Gallons Min. Eff Distribution Status
Enera Pro 7.2 by Enera Soft User Number: 6712
ID:
Pace 19 of 51
IG
2016 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used, Review the respective section for more information. `Exceptions may apply.
(Revised 04/20171
Building Envelope Measures:
§ 110.6(a)l:
Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft2 or less when tested per
NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-2011.'
§ 110.6(a)5:
Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a).
§ 110.6(b):
Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES
110.6-A and 110.6-B for compliance and must be caulked and/or weatherstri ed.'
§ 110.7:
_
Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
asketed or weather stripped.
§ 110.8(a):
Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material.
§ 110.8(g):
Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g).
§ 110.8(i):
Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing
material must meet the requirements of § 11 0.8i when the installation of a cool roof is specified on the CF1 R.
§ 110.80):
Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043.
Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
§ 150.0(a):
insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited
to placing insulation either above or below the roof deck or on top of a drywall ceilin .'
§ 150.0(b):
Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value.
Above Grade Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-
§ 150.0(c):
factor of 0.074 or less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed
value of R-13 in a wood framed assembly.*
§ 150.0(d):
Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor,'
§ 150.0(f):
Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light
deterioration and when installed as pad of a heated slab floor, meet the requirements of § 1 10.8.
§ 150.0(g)l:
Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This
requirement also applies to controlled ventilation crawls ace for buildings complying with the. exception to § 150.0 d .
§ 150.0(g)2:
Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all
insutation in ail exterior walls vented attics and unvented attics with alr- ermeable insulation.
150.0
§ (q)'
Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
maximum U-factor of 0.58; or the weighted avers a U-factor of all fenestration must not exceed 0.58.'
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 150.0(e)lA:
Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)l B:
Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area
and is a ui ed with a readily accessible operable, and tight -fitting damper or combustion -air control device.'
§ 150.0(e)1C:
_
Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.'
§ 150.0(e)2:
Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of
the building, are prohibited.
Space Conditioning, Water Heating, and Plumbing System Measures:
§ 110.0-§ 110.3:
Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
must be certified by the manufacturer to the Energy Commission.'
§ 110.2(a):
_appliances
HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.'
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§ 110.2(b):
must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for
compression heating is higher than the cut-off temperature for supplementary heating..*
§ 110.2(c):
Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat.'
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
§ 110.3(c)5:
meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of §
110.3(c)5.
§ 110.3(c)7:
Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTUfhr (2 kW) must have isolation valves with hose bibbs
or other fittings on both cold water and hot water lines of water heating systems to allow for water tank hushing when the valves are closed.
§ 110.5:
Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli-
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt): and pool and spa heaters'
Building Cooling and Heating Loads. Heating andlor cooling loads are calculated in accordance with ASHRAE Handbook, Equipment
§ 150.0(h)l:
Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; orACCA
Manual J using design conditions specified in § 1%0 h 2.
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(h)3A:
Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any
drier vent.
§ 150.0(h)3B:
Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by
manufacturer's instructions.
§ 150.00)1:
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must
be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a
§ 150.00)2A:
nominal diameter of 314 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter;
piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to
kitchen fixtures.'
§ 150.00)2B:
Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof
and non -crushable casing or sleeve.'
§ 150.00)2C:
Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution
piping for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.'
§ 150.00)3:
Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by
§ 150.00)3A:
aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can
cause de radation of the material.
§ 150.06)3B:
Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a
Class I or Class II vapor retarder.
Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a
§ 150.0(n)1:
120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside
termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the
water heater, and allows natural draining without pump assistance; and a gas suppI line with a capacity of at least 200,000 Btu/hr.
§ 150.0(n)2:
Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
§ 150.0(n)3.
Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification
Corporation SRCC or by a listing agency that is approved by the Executive Director.
Ducts and Fans Measures:
§ 110.8(d)3:
Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a
contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement.
CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC
§§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSIISMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or
a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing
§ 150.0(m)1:
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than'/4 inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain
ducts. Ducts fnstalied in cavities and support pjalforms must not be compressed to cause reductions in the cross -sectional area of the ducts:
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
§ 150.0(m)2:
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such toe is used in combination with mastic and draw bands.
§ 150.0(m)3:
Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
mastics, sealants, and other requirements specified for duct construction.
§ 150.0(m)7:
Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
automatic dampers.
§ 150.0(m)8:
Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually operated dampers in all openings to the outside except combustion inlet and outlet air o enin s and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
§ 150.0(m)9:
wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation.
§ 150.0(m)10:
Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)11:
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 150.0 m 11 and Reference Residential Appendix RA3.
Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,
pressure drop, and labeling re uirements of § 150.0(m)12.
2016 Low -Rise Residential Mandatory Measures Summary
Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable
space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the
§ 150.0(m)13:
supply plenum. The space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with
Reference Residential Appendix RAU. This applies to both single zone central forced air systems and every zone for zonally controlled central
forced airs stems.'
Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor
§150.0(o):
continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of
providing whole -building ventilation.
§ 150.0(o)1A:
Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.7.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
§ 110.4(a):
that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heating.*
§ 110.4(b)1:
Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated
suction and return lines, or built-in or built-up connections to allow for future solar heating.
§ 110.4(b)2:
Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b)3:
Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
will allow all pumps to be set or programmed to run only during off-peak electric demand periods.
§ 110.5:
Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
150.0
§ (p)'
Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
rate, pining, filters, and valves.'
Lighting Measures;
§ 110.9:
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
of 110.9.*
§ 110.9(e):
JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must
be certified to the Energy Commission according to Reference Joint Appendix JA8.
§ 150.0(k)1A:
Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or
§ 150.0(k)1 B:
other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fan speed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)1 C:
labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C. A JA8-2016-E light source rated for
elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings.
§ 150.0(k)1 D:
Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than
20 kHz.
Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no
§ 150.0(k)1 E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled
by vacancy sensors.
§ 150.0(k)1 F:
Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
must meet the applicable requirements of § 150.0(k).'
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply
§ 150.0(k)1 G;
with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix
JA8.'
§ 150.0(k)1 H:
Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E."
§ 150.0(k)2A:
Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B:
Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.'
§ 150.0(k)2C:
Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually
switched ON and OFF.
§ 150.0(k)2D:
_
Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with
150.0(k).
§ 150.0(k)2F:
Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it:
§ 150.0(k)2G:
functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of §
130.5(fD; and meets all other requirements in § 150.0(k)2.
Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the
§ 150.0(k)2H:
following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of §
130.5 ; and all other requirements in § 150.0 k 2.
§ 150.0(k)21:
Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
provides the functionality of a dimmer according to § 110.9 and complies with all otherapplicable requirements in § 150.0(k)2.
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(k)2J:
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
be controlled byvacancy sensor.
§ 150.0(k)2K:
_a _
Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with
Reference. Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.'
§ 150.0(k)2L:
Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A:
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item
§ 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or
EMCS).
Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies,
§ 150.0(k)3B:
and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with
either 150.0 k 3A or with the applicable requirements in §§ 110.9, 130.0, 130.2,130.4, 140.7 and 141.0.
§ 150.0(k)3C:
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by
150.0 k 3B or § 150.0 k 3D must comply with the applicable requirements in §§ 110.9 130.0 130.2 130.4 140.7 and 141.0.
§ 150.0(k)3D:
Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more
vehicles per site must comply with the applicable requirements in §§ 110.9. 130.0. 130.2, 130.4.140.7, and 141.0.
§ 150.0(k)4:
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
power as determined according to § 130.0(c).
§ 150.0(k)5:
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
applicable requirements for nonresidential garages in §5 110.9, 130.0, 130.1 130.4 140.E and 141.0.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A:
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be high efficacy luminaires and controlled by an occupant sensor.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must:
§ 150.0(k)6B:
i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress
-
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1:
application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the
requirements of § 110.10 b I hfo ug h § 110.1D e .
§ 110.10(a)2:
Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110,10(b) through § 110.10(d).
Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local
jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet
each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas
§ 110.10(b)1:
greater than 10,000 square feet.
For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250
square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang
of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less
than 15 percant of the total roof area of the building excluding any sk I ht area.'
§ 110.10(b)2:
Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.'
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)3B:
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone, measured in the vertical plane.'
§ 110.10(b)4:
Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof
dead load and roof live load must be clearty indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for
§ 110.10(c):
routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system.
§ 110.10(d):
Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
§ 110.10(c) must be provided to the occupant.
§ 110.10(e)1:
Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2:
breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or
main circuit location; and permanently marked as "For Future Solar Electric".
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Tonkin Residence
Date
12/6/2018
System Name
HVAC-Master
Floor Area
1,361
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 691
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation E 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output perSystem
89,000
14,399
1,794
421
15,541
Total Output Btuh
89,000
0
Output Btuh/s ft
65.4
831
764
Cooling System
0
0
Output perSystem
57,500
0
0
0
0
Total Output Btuh
57,500
89
1,794
-89
Total Output (Tons)
4.8
831
764
Total output Btuh/s ft
42.2
Total Out ut s ft/Ton
284.0
16,151
16,986
Air System
CFM perSystem
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
2,000
Carrier 214ANB760/58PH**110
42,711
5,867
89,000
Airflow (cfm/s ft
1.47
Airflow cfmfTon
417.4
Outside Air %
0.0 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
42,711
5.867
89,000
Jan 1 AM
Outside Air cfm/s ft
0,00
Note: values abase given at AR1 conditions
Aug 3 PM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF
Outside Air
0 cfm
70 OF
70 OF 105 IF 105 IF
Heating Coil Supply Fan
2,000 cfm
0 I
ROOM
70 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling
Peak
112/78IF
Outside Air
0 cfm
75 / 62 OF
75/62OF 55/54IF 55/54OF
Cooling Coil Supply Fan
2,000 cfm
11
55 / 54 OF
47.2 % ROOM
it
75 / 62 OF
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Tonkin Residence
System Name
HVAC-Great/Living/Kit. /Din.
Date
12/6/2018
Floor Area
3,637
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
3
COIL
LCFM
Total Room Loads2,371
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 61,000
49,075
4,7951 1,354
49,746
Total Output Btuh
183,000
Output Btuh/s ft
50.3
2,833
2,445
Cooling System
01
0
Output EerSystem
49,000
01 0
0
0
Total Output Btuh
147,000
01
2,833
54,741 4,795
0
Total Ou ut Tons
12.3
2,445
Total Output Btuh/s ft
40.4
Total Output s ft/Ton
296.9
54,636
Air System
CFM perSystem
1,600
HVAC EQUIPMENT SELECTION
Airflow 0m
4,800
Carrier 24ANB748-58CVX080
110,908
13,445
183,000
Airflow cfmis ft
1.32
Airflow cfmlTon)
391.8
Outside Air (%)
0•0 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
110,908
13,445
183,000
Jan 1 AM
Outside Air cfmis ft
0.00
Note: values above given at ARI conditions
Aug 3 PM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak)
26 OF 70 OF 105 OF ^ 105 OF
Outside Air H
0 cfm Heating Coil Supply Fan
4,800 cfm
70 OF
E05F
ROOM
70 °F
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling
Peak
112 / 78 OF
Outside Air
0 cfm
76 / 62 OF
76 162 OF 55 / 54 OF 55 / 54 OF
Cooling Coil Supply Fan
4,800 cfm
56 / 54 OF
47.3% ROOM
75 162 T
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Tonkin Residence
System Name
HVAC-Casita
Date
12/6/2018
Floor Area
1,271
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 873
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
61,000
18.019
1.676
532
19,492
Total Output (Btuh)
61,000
0
-Output Btuh/s ft
48.0
1,040
958
Cooling System
0
0
Outj2ut per System
49,000
0
fl
0
0
Total Output Btuh
49,000
0
1,e76
0
Total Output Tons
4•1
1,040
958
Total Output Btuh/s ft
38.6
Total Output s ft/Ton
311.3
1 20,099
21,407
Air System
CFM per System
1,600
HVAC EQUIPMENT SELECTION
Airfiow cfm
1,600
Carrier 24ANB748-58CVX080
36,999
4,473
61,000
Airflow cfm/s ft
1.26
Airflow cfm/Ton
391 Z
Outside Air %a
0.0 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
36,999 4,473
Aug 3 PM
61,000
Jan 1 AM
Outside Air efmis ft
0.00
Note: values above -given at ARI conditions I
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF
Outside Air
0 cfm
69 IF
69 OF 105 IF 105 IF
t ►
Heating Coil Supply Fan
1,600 cfm
ll I
104 OF
ROOM''
,
70 IF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling
Peak
112/78°F
Outside Air
0 cfm
76/62°F
76/62°F 55/54°F 55/54°F
Cooling Coil Supply Fan
1.600 cfm
56 / 54 OF
47.3 % ROOM
_ A_.__
75/62°F
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Tonkin Residence
System Name
HVAC-2nd Floor
Date
12/6/2018
Floor Area
1,014
ENGINEERING CHECKS
SYSTEM LOAD
Number of S stems
1
COIL
CFM
Total Room Loads 668
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation I 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output perSystem
61,000
13,878
1.337
323
11,923
Total Output Btuh
61,000
0
Output Btuh/s ft .
60.2
801
586
Cooling System
0
0
Output perSystem
49,000
0
0
0
0
Total Output Btuh
49,000
0
1,337
0
Total Output Tons
4.1
801
586
Total Output Btuh/s ft
48.3
Total Output s ft/Ton
248.3
1 15,480
13,095
Air System
CFM perSystem
1,600
HVAC EQUIPMENT SELECTION
Airflow cfm
1,600
Carrier 24 ANB748-58CVX080
36,980
4,417
61,000
Airflow cfm1s ft
1.58
Airflow cfmfTon
391.8
Outside Air (%)
0•0 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
36,980
4,417
61,000
Jan 1 AM
Outside Air cfm/s ft
0.00
Note: values above given at ARI conditions 1
Aug 3 PM
HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating
Peak
26 OF
Outside Air Ar
0 cfm
70 OF
70 OF 105 OF 105 OF
I 1
Heating Coil Supply Fan
1,600 cfm
1 1 1 1 U
1
ROOM
70 °F
COOLING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Cooling
Peak
112/78°F
Outside Air
0 cfm
75/62OF
75/62OF 55/54OF 55/54OF
ll
Cooling Coil Supply Fan
1,600 cfm
fl { 1 I 1
��JJ
55 / 54 OF
---
47.1 % ROOM
ZONE LOAD SUMMARY
Project Name
Tonkin Residence
System Name
HVAC-Master
Date
12/6/2018
Floor Area
1,361
ZONE LOAD SUMMARY
ZONAL SYSTEM
COOLING PEAK
HEATING PEAK
ZONE NAME
SYSTEM NAME
Mult.
CFM
Sensible
Latent
Heating
OA CFM
Peak Hr
CFM
Sensible
Latent
CFM
Sensible
Master Suite
1.0
0
Aug 3 PM
691
14,399
1,794
421
15,547
l
TOTALS
0
0
01
0
Aug 3 PM
1 14,399
1,794
15,547
(BLOCK LOAD)
ZONE LOAD SUMMARY
Project Name
Tonkin Residence
Date
121612018
System Name
HVAC-Greaftiving/Kit. /Din.
Floor Area
3,637
ZONE LOAD SUMMARY
ZONAL SYSTEM
COOLING PEAK
HEATING PEAK
ZONE NAME
SYSTEM NAME
Mult.
CFM
Sensible
Latent
Heating
OA CFM
Peak Hr
CFM
Sensible
Latent
CFM
Sensible
Living Space
1.0
0
Aug 3 PM
2,167
44,845
4,340
1,221
44,846
Bdrms 2
1.0
0
Aug 3 PM
204
4,230
455
133
4,900
TOTALS
0
0
01
0
Aug 3 PM
49, 075', 4,795
49,746
(BLOCK LOAD)
ZONE LOAD SUMMARY
Project Name
Tonkin Residence
Date
12/6/2018
System Name
H VA C-Casita
Floor Area
1,271
ZONE LOAD SUMMARY
ZONAL SYSTEM
COOLING PEAK
HEATING PEAK
ZONE NAME
SYSTEM NAME
Mult.
CFM
Sensible
Latent
Heating
OA CFM
Peak Hr
CFM
Sensible
Latent
CFM
I Sensible
Casita Zone
1.0
01
Aug 3 PM
873
18,019
1,676
532
19,492
TOTALS.
0
01
0
0
Aug 3 PM
18,019
1,676
19,492
(BLOCK LOAD)
ZONE LOAD SUMMARY
Project Name
Tonkin Residence
Date
121612018
System Name
HVAC-2nd Floor
Floor Area
1,014
ZONE LOAD SUMMARY
ZONAL SYSTEM
COOLING PEAK
HEATING PEAK
ZONE NAME
SYSTEM NAME
Mult.
CFM
Sensible
Latent
Heating
OA CFM
Peak Hr
CFM
Sensible
Latent
CFM
I Sensible
2nd Floor
1.0
0
Aug 3 PM
668
13,878
1,337
323
11,923
TOTALS1
0
0
0
0
Aug 3 PM
13,8781
1,337
11,923
(BLOCK LOAD)
ROOM LOAD SUMMARY
Project Name
Tonkin Residence
System Name
HVAC-Master
ROOM LOAD SUMMARY
Date
121612018
Floor Area
1,361
ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. I CFM I Sensible I Latent CFM Sensible I Latent CFM Sensible
Master Suite Master 1 1 691 14,399 1,794 691 14,3991 1,794 421 15,547
PAGE TOTAL
TOTAL*
* Total includes ventilation load for zonal
691
14,399 1,794
421
15,547
691
14,399 1,7941
4211
15,547 ]
ROOM LOAD SUMMARY
Project Name Date
Tonkin Residence 121612018
System Name Floor Area
HVAC-Greaftivin /Kit. Min. 3,637
ROOM LOAD SUMMARY
Zone Name Room Name
Living Space Living Area
Living
2 Bedrooms 2
I * Total includes ventilation load for zonal systems.
ROOM COOLING PEAK
Mult. CFM Sensible Latent
1 2,167 44,845 4,340
1 204 4,230 455
PAGE TOTAL
TOTAL*
COIL COOLING PEAK
CFM Sensible Latent
2,167 44,845 4,341
204 4,230 45,
COIL HTG. PEAK
CFM Sensible
1,221 44,846
133 4,900
2,371
49.075
4,795
1,354
49,746
Z3711
49,0751
4,7951
1.354
49,7461
ROOM LOAD SUMMARY
Project Name Date
Tonkin Residence 12/6/2018
System Name Floor Area
HVAC-Casita 1,271
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK_ COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible I Latent CFM Sensible Latent CFM I Sensible
rsC,., ita Zone eCasita 1 1 8731 18,0191 1,676 8731 18,019 1,676 5321 19,492
PAGE TOTAL
TOTAL*
* Total includes ventilation load for zonal systems.
873
18,019 1,676
532
19,492
873
18,019 1,676
532
19,492
ROOM LOAD SUMMARY
Project Name
Tonkin Residence
System Name
HVAC-2nd Floor
ROOM LOAD SUMMARY
Zone Name
2nd Floor
Room Name
Second Floor
Total includes ventilation load for zonal
ROOM COOLING PEAK
Mult. CFM Sensible Latent
1 668 13,8781 1,337
PAGE TOTAL
TOTAL"
Date
121612018
Floor Area
1,014
COIL COOLING PEAK COIL HTG. PEAK
CFM Sensible I Latent CFM I Sensible
6681 13,8781 1,337 3231 11,923
6.88
13,878
1,337 323
11,923
668
13,878
1,337 323
11,923I
ROOM HEATING PEAK LOADS
Project Name Date
Tonkin Residence 121612018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Master
Floor Area 1,361.00 ft2
Indoor Dry Bulb Temperature 70 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U-Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT OF
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
44
Btu/hr
R-38 Roof Affic R19 High Performance
1.361.0
0.0174
44
1,042
R-21 Wall
1,230.8
0.0690
44
3,737
Sierra Pacific .261.16
25.2
0-2500
44
277
La Cantina .411.21
184.0
0.4100
44
3,319
FR. Door.391..18
20.0
0.3900
44
343
Slab -On -Grade
perim = 112.0
0.7300
44
0
3,597
'R-0 inferior Surface
530.0
0.3560
0
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 1,361 X
Area
another room
10.00 X 0.304
Height Aai
Page Total
/ 60 ] X
AT
12,316
T 3,231
TOTAL HOURLY HEAT LOSS FOR ROOM 15,547
ROOM HEATING PEAK LOADS
Project Name
Tonkin Residence
Date
121612018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Living Area
Floor Area 3,292.00 ft2
Indoor Dry Bulb Temperature 70 °F
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U-Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT °F
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
44
Btu/hr
R-36 Roof Attic R19 Nigh Performance
3,292.0
0.0174
44
Z521
R-21 Wag
2,098.0
0.0690
44
6,370
Sierra Pacific .261..15
700.0
0.2500
44
7.700
FR. Dom.391..18
40.0
0.3900
44
686
La Can[ina .41/.21
600.0
0.4100
44
10,824
Slab -On -Grade
perim = 2 78. 0
0.7300
44
8,929
'R-0 Interior Surface
890.0
0.3560
0
0
items shown with an asterisk (`) denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 3,292 X
Area
another room
13.40 X 0.227
Height ACH
Page Total
/ 60 ] X
AT
37,030
= 7,815
TOTAL HOURLY HEAT LOSS FOR ROOM 44,846
ROOM HEATING PEAK LOADS
Project Name Date
Tonkin Residence 121612018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Bedrooms 2
Floor Area 345.00 ftZ
Indoor Dry Bulb Temperature 70 OF11
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Coiling
U-Value
0.0174
AT OF
X 44
X 44
X 44
X _ 44
X 44
X 0
X
=
=
=
=
_
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
,
49
Btu/hr
R-36 RoafAttic R19 High Performance
345.0
264
R-21 Wall
366.01
0.0690
1,111
La Canfina ,41121
68.0
0.4100
1,227
Sierra Pacific .261..16
6.0
0.2500
66
Siab-On-Grade
perim = 44.0
0.7300
1,413
Ft-0 Interior Surface
360.0
0.3560
0
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 345 X
Area
another room
10.00 X 0.304
Height ACK
Page Total
/ 60 ] X
AT
4,081
= 819
TOTAL HOURLY HEAT LOSS FOR ROOM 4,900
ROOM HEATING PEAK LOADS
Project Name 1 Date
Tonkin Residence 1 121612018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Casita
Floor Area 1,271.00 ftz
Indoor Dry Bulb Temperature 70 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
to
Ceiling
U-Value
AT °F
X 44
X 44
X 44
X 44
X 44
X 44
X 0
X
X
X
X
X
X
X
X
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Page Total
/ 60 J X
AT
=
=
=
=
=
_
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
44
Btu/hr
R 38 RoofA[fic R19 Nigh Performance
1,271.0
0.0174
973
R-21 Wall
1,259.6
0.0690
3,824
Sierra Pacifra .2fi/.16
398.4
0.2500
4,382
FR. Door 391.18
20.0
0.3900
343
Le Canine .411.21
104.0
0.4100
1,876
Slab -On -Grade
perim = 158.0
0.7300
5,075
'R-0 Inferior Surface
530.0
0.3560
0
Items shown with an asterisk (`) denote conduction
Infiltration:[ 1.00 X 1.064
50edule Air Sensible
Fraction
through an interior surface
X 1,271 X
Area
another room
10.90 X 0.279
Height ACH
f6,474
3,017
TOTAL HOURLY HEAT LOSS FOR ROOM 19,492
ROOM HEATING PEAK LOADS
Project Name Date
Tonkin Residence 12/6/2018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Second Floor
Floor Area 1,014.00 ft2
Indoor Dry Bulb Temperature 70 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
to
Ceiling
U-Value
AT *F
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
_
_
44
Btu/hr
R-38 Roof Attic R19 Nigh Performance
1,014.0
0.0174 x
44
776
R-21 Watt
1,084.1
0.0690 x
0.25001 x
0.3900 x
0.0370 x
0.3560 x
fx
Ix
Jx
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
another room
9.50 x 0.320
Height A;I I
44
3,291
Sierra Pacific .261.16
115.9
44
44
1,275
FR. Door.391.18
208.0
3,569
R-19 Floor
371.0
44
604
`R-0 Interior Surface
530.0
0
0
Items shown with an asterisk (") denote conduction
Infiltration:[ 1.00 x 1.064
Schedule Air Sensible
Fraction
through an interior surface
x 1,014 x
Area
Page Total
/ 60 ] x
AT
9,51.6
= 2,407
TOTAL HOURLY HEAT LOSS FOR ROOM 11,923
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Tonkin Residence
1 121612018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Master
Outdoor Dry Bulb Temperature
2 OF
Floor Area
1,361.00 ftz
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 75 OF,
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btu/hr
R-38 Roof Atlic R19 Nigh Performa (N) 1,361.0 x 0.0174
x
56.0 = 1.326
R-21 Wall
(E) 271.1 x 0.0690
x
31.7 c 592
R•21 Wall
(S) 350.0 x 0.0690
x
27.7 = 668
R-21 Walf
(W) 433.7 x 0.0690
x
32.3 = 968
R-21 WAIL
(N) 176.0 x 0.0690
x
29.0 = 352
'R-0 Interior Surface
530.0 x 0.3560
x
0.0 = 0
x
x
=
x
x
=
x
x
=
Page Total 3.907
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF Btulhr
X
(E) 0.0 x 10.9 +
6.3
x
19.0 = 120
Y
(E) 0.0 x 10.9 +
6.3
x
19.0 = 120
Z
(E) 0.0 x 10.9 +
6.3
x
19.0 = 120
M
(W) 0.0 x 10.9 +
6.3
x
19.9 = 125
16
(W) 80.0 x 16.0 +
0.0
x
27.8 = 1,279
15
(W) 0.0 x 14.5 +
20.0
x
24.6 = 491
14
(N) 0.0 x 16.0 +
104.0
x
22.7 = 2,366
x
x
=
x
x
=
Page Total 4,621
Internal Gain
Btu/hr
Occupants
41 Occupants x 245
Btuh/occ.
= 1,001
Equipment
1,361 Floor Area x _ 0.50
w/sgft
= 2,323
Infiltration: 1.064
x 0.89 x 72.50 x 37
Z548
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
14,399
Latent Gain
Btu/hr
Occupants
4.1 =1 Occupants x 155
Btuh/occ.
= C'33
Infiltration: 4,771
x 0.89 X 72.50 X 0.00376
1,161
Air Latent
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
633
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Tonkin Residence 121612018
ROOM INFORMATION DESIGN CONDITIONS
Room Name Living Area Outdoor Dry Bulb Temperature 112 OF
Floor Area 3,292.00 ft2 Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 75 OF Outdoor Daily Range: 34 OF
Opaque Surfaces
P-38 Roof Attic R19 High Performa
R-21 Wall
R-21 Wall
R-21 Wall
R-21 Wall
R-21 Wall
'R-0 Interior Surface
Orientation
(N)
(NE)
(SE)
(S)
(SW)
(NW)
Area
X
X
X
X
X
X
X
x
x
U-Factor
X
X
X
X
X
X
X
x
x
CLTD'
=
=
=
=
=
=
-
3,292.0
0.0174
56.0
438.0
0.0690
29.0
602.0
0.0690
31.0
108.0
0.0690
27.7
510.0
0.0690
31.0
440.0
0.0690
30.2
890.0
0.3560
0.0
Page Total
Items shown with an asterisk (") denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
K
9
J
2
B
1
A
AA
cc
Internal Gain
Orientation
(NE)
(NE)
(NE)
(SE)
(SE)
(SE)
(SE)
(SE)
(SE)
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
-
0.0
10.9
130.0
16.1
0.0
14.5
40.0
20.3
0.0
10.9
25.0
16,1
100.0
16.0
0.0
20.8
65.0
10.9
0.0
14.6
80.0
10.9
0.0
14.6
65.0
10.9
0.0
14.6
0.0
10.9
60.0
14.6
0.0
10.9
7.5
14.6
Page Total
9 9 1 Occupants X 245 Btuh/occ.
3,292 1 Floor Area X 0.50 w/sgft
Infiltration: 1.064 X 0.89 X 175.37 X 37 W
Air Sensihfe CFM ELA AT
Btu/hr
3,208
876
1,286
206
1,091
918
0
7.5871
Btu/hr
2,091
811
402
1.599
711
875
711
1,170
110
8.479
Btu/hr
2,422
5,618
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 44,845
Latent Gain Btu/hr
Occupants 9 9 Occupants X 1551 Btuh/occ. = 1532
Infiltration: 4,771 X 0.89 X 175.37 X 0.00376 = 2,809
Air Latent CFM ELA ❑w
I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,5321
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Tonkin Residence
121612018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Living Area
Outdoor Dry Bulb Temperature
112 OF
Floor Area
3,292.00 ftZ
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 75 OF,
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor CLTD'
Btu/hr
X X
=
X X
_
X X
=
X X
X X
=
X X
=
X X
=
X X
=
X X
=
Page Total
0
Items shown with an asterisk (`)
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded Unshaded
Fenestration
Orientation Area GLF Area GLF
Btu/hr
DD
(SE) 0.0 X 10.9 + 7.5 X
14.6 =
110
AA
(S) 0.0 X 10.9 + 80.0 X
12.2 =
975
D
(SW) 0.0 X 10.9 + 16.0 X
14.6 =
234
C
(SW) 40.0 X 10.9 + 0.0 X
14.6 =
437
BB
(S W) 0.0 X 10.9 + 10.0 X
14.6 =
146
BB
(SW) 0.0 X 10.9 + 11.0 X
14.6 =
161
BB
(SW) 0.0 X 10.9 + 11.0 X
14.6 =
161
BB
(SW) 0.0 X 10.9 + 10.0 X
14.6 =
146
13
(NW) 0.0 X 16.0 + 300.0 X
22.7 =
6824
Page Total
9,194
Internal Gain
Occupants
9•9 Occupants X 245 Btuh/occ.
13,292
Btu/hr
2,422
Equipment
Floor Area X 0.50 w/sgft
_
5,618
Infiltration: 1.064
X 0.89 X 175.57 X 37 =
6,163
Air Sensible
CFM EIA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
44,845
Latent Gain
Btu/hr
Occupants
9 9 Occupants X 1551 Btuh/occ.
=
1,532
Infiltration: 4,771
X 0.89 X 175.37j X �_00376I =
2,808
Air Latent
CF 1V1 ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
1,532
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Tonkin Residence
121612018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Living Area
Outdoor Dry Bulb Temperature
112 OF
Floor Area
3,292.00 ft'
Outdoor Wet Bulb Temperature
78 OF
Indoor D Bulb Temperature 75 °F
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
0
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF
Area
GLF Btu/hr
12
(NW) 0.0 X 16.0 +
50.0
X
22.7 = 1.131
11
(NW) 0.0 X 16.0 +
150.0 X
22.7 = 3,412
EE
(NW) 0.0 X 10.9 +
7.5
X
16.1 = 121
FF
(NW) 0.0 X 10.9 +
7.5
X
16.1 = 121
GG
(NW) 0.0 X 10.9 +
7.5
X
16.1 = 121
HH
(NW) 0.0 X 10.9 +
7.5
X
16.1 = 121
L
(s) 32.0 X 10.9 +
0.0
X
12.2 = 350
X +
X
=
X +
X
=
Page Total 5,382
Internal Gain
Occupants
9.9 Occupants X 245
Btuh/occ.
Btu/hr
= 2,422
E ui ment
3,292 Floor Area X 0.50
w/sgft
= 5,6i8
Infiltration: 1.064
X 0.89 X 175.37 X 37 =
6,163
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
44,845
Latent Gain
Btu/hr
(]c-c:upanls
9•9 1 Occupants X 155
Btuh/occ.
= 1.532
Infiltration: 4,771
X o.89 X ! 175.37 X 0.00376 =
2,608
Air Latent
CFM FLA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
1,532
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Tonkin Residence
12/6/2018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Bedrooms 2
Outdoor Dry Bulb Temperature
112 OF
Floor Area
345.00 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor D Bulb Temperature 75 OF1
Outdoor Daily Ran e:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btu/hr
R-38 Roof Attic R19 Nigh Aerforma (N) 345.0 X 0.0174
X
56.0 =
336
R 21 Wall
(NE) 121.0 X 0.0690
X
29.0 =
242
R-21 Wafi
(SE) 175.0 X 0.0690
X
31.0 =
374
R-21 Wall
(NW) 70.0 X 0.0690
T
X
30.2 =
146
'R-0 Interior Surface
360.0 X 0.3560
X
0.0 =
0
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
1,099
Items shown with an asterisk (")
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
$
(NE) 0.0 X 16.0 +
68.0
X 22.7 =
1,547
H
(NE) 0.0 X 10.9 +
6.0
X 16.1 =
96
X +
X
X +
X
X +
X -
X +
X -
X +
X =
X +
X =
X +
X
Page Total
1.643
Internal Gain
Btuthr
Occupants
1.0 Occupants X 245
1
Btuh/occ.
Equipment
345 Floor Area X _ 0.50
w/sgft
=
589
Infiltration: 1.064
X 0.89 X 18.38 X 37 =
646
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
4,230
Latent Gain
Btu/hr
Occupants
1.0 Occupants X 555
Btuh/occ.
=
161
Infiltration: 4,771
X 0.89 X 18.38 X 0.00376 =
294
Air Latent
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
161
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Tonkin Residence
121612018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Casita
Outdoor Dry Bulb Temperature
112 OF
Floor Area 1,271.00 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor D Bulb Temperature 75 °F
Outdoor DailM Range:
34 OF
Opaque Surfaces Orientation Area U-Factor
CLTD'
Btu/hr
R-38 Roof Attic R19 Nigh Performa (N) 1,271.0 X 0.0174
X
56.0 = 1,239
R-21 Wall (E) 329.9 X 0.0690
X
31.7 = 721
R-21 well (s) 251.6 X 0.0690
X
27.7 = 480
R-21 Wall (W) 333.5 X 0.0690
X
32.3 = 744
R-21 Wall (N) 344.6 X 0.0690
X
29.0 = 690
"R-0 Interior Surface 530.0 X 0.3560
X
0.0 = 0
X
X
=
X
X
=
X
X
=
Page Total 3,873
Items shown with an asterisk (") denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF Area
GLF Btu/hr
W (E) 7.5 X 10.9 +
0.0
X
19.0 = 82
19 (E) 10.4 X 14.5 +
9.6
X
23.5 = 376
U (E) 0.0 X 10.9 +
44.0
X
19.0 = 835
NN (E) 0.0 X M 9 +
4.6
X
19.0 = 87
PP( (E) 0.0 X 10.9 +
4.6
X
19.0 = 87
QQ (E) 0.0 X 10.9 +
4.6
X
19.0 = 87
RR (E) 0.0 X 10.9 +
4.6
X
19.0 = 87
ss (E) 0.0 X 10.9 +
4.6
X
19.0 = 87
TT (E) 0.0 X 10.9 +
4.6
X
19.0 = 67
Page
Total
Internal Gain
Btu/hr
Occupants 3.8 X 245
Btuh/occ.
935
_Occupants
Equipment 1,271 Floor Area X 0.50
w/sg
Z169
Infiltration: 7.064 X = 0.89 X L 77.71 X 37 =
2,380
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
18,019
Latent Gain
Btu[hr
Occupants 3 8 Occupants X _ 155
Btuh/occ.
= 592
Infiltration: 4,771 X 0.89 X = 677771 X 0.003761 =
1,0$4
Air Latent CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
592
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
Tonkin Residence 121612018
ROOM INFORMATION DESIGN CONDITIONS
Room Name Casita Outdoor Dry Bulb Temperature 112 OF
Floor Area 1,271.00 ftZ Outdoor Wet Bulb Temperature 78 OF
Indoor Dry Bulb Temperature 75 OF Outdoor Dailv Ranae: 34 OF
ue Surfaces
Orientation
Area
X
X
X
X
X
X
X
X
X
U-Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
Page Total
Items shown, with an asterisk (") denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
U
r
s
R
AF
AG
AN
AJ
Q
nripntatinn
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
0.0
10.9
154.0
12.2
0.0
10.9
6.0
12.2
0.0
10.9
6.0
12.2
0.0
10.9
30.0
12.2
0.0
10.9
4.6
12.2
0.0
10.9
4.6
12.2
0.0
10.9
4.6
12.2
0.0
10.9
4.6
12.2
0.0
10.9
6.3
19.9
Page Total
Btu/hr
Btu/hr
1 561
2,
Internal Gain Btu/hr
Occupants 3 8 Occupants X 245 Btuh/occ.
Equipment 1,271 Floor Area X 0.50� w/sgft n 2,
Infiltration: 1.064 X 0.891 X 67.71 X 371 = 2.,
Air 5ensfble CFM ElA 4T
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 18,019
Latent Gain Btu/hr
Occupants 3 8 Occupants X 155 Btuh/occ. = 592
Infiltration: 4,771 X 0 89� X 67.71 X 0.00376 W �;D614
Air Latent C f M ELA AVN
I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 5921
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Tonkin Residence
121612018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Casita
Outdoor Dry Bulb Temperature
112 OF
Floor Area
1,271.00 ftz
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 75 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
TO
Items shown with an asterisk (')
denote conduction through an interior surface to another room-
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area GLF
Btu/hr
P
(W) 0.0 X 10.9 +
6.3 X
19.9
= 125
N
(W) 0.0 X 10.9 +
6.3 X
19.9
= 125
YY
(W) 0.0 X 10.9 +
4.6 X
19.9
= 92
z7
(W) 0.0 X 10.9 +
4.6 X
19.9
= 92
AB
(W) 0.0 X 10.9 +
4.6 X
19.9
= 92
AC
(W) 0.0 X 10.9 +
4.6 X
19.9
= 92
AD
(W) 0.0 X 10.9 +
4.6 X
19.9
= 92
AE
(W) 0.0 X 10.9 +
4.6 X
19.9
= 92
14
(N) 0.0 X 16.0 +
104.0 X
22.7
=
Page Total
�--q
Internal Gain
Occupants
3-8 Occupants X 245
Btuh/occ,
Btu/hr
935
Equipment
1,271 _ Floor Area X 0.50
w/sgft
=
2,169
Infiltration: 1.064
X 0.89 X 67.71 X 37 =
2,380
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
18,019
Latent Gain
Btu/hr
Occupants
3 8 _ Occupants X 155
Btuh/occ.
_
_592
Infiltration: 4,771
X 0.89 X 67.71� X 0.00376 =
7,084
Air Latent
CFM EI.A MV
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
592
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Tonkin Residence
121612018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Casita
Outdoor Dry Bulb Temperature
112 OF
Floor Area 1,271.00 ftZ
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
75 OF1
Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation
Area U-Factor CLTD'
X X
=
Btu/hr
X X
=
X X
=
X X
=
X X
_
X X
=
X X
=
X X
=
X X
=
Page Total
Items shown with an asterisk (") denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fenestration Orientation
Area GLF Area GLF
Btu/hr
V (N)
0.01 X 10.9 + 16.0 X
16.1 =
257
id (N)
0.0 X 10.9 + 6.0 X
16.1 =
96
KK (N)
0.0 X 10.9 + 6.0 X
16.1 =
96
LL (N)
0.0 X 10.9 + 6.0 X
16.1 =
96
MM (N)
0.0 X 10.9 + 6.0 X
16.1 =
96
UU (N)
0.0 X 10.9 + 4.6 X
16.1 =
74
VV (N)
0.0 X 10.9 + 4.6 X
16.1 =
74
tMIN (N)
0.0 X 10.9 + 4.6 X
16.1 =
74
XX (N)
0.0 X 10.9 + 4.6 X
16.1
74
Page Total
939
Internal Gain
Occupants 3 8 Occupants
_
X 245 Btuh/occ.
»
Btu/hr
d!935E
ui ment 1,271 Floor Area
X o.50 w/sgft
Z
Infiltration: 1.064 X 0.89 X 67.71 X 37 =
2,360
Air Sensible CFM ELA
AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
18,019
Latent Gain
Occupants 38 Occupants
155Btuh/occ.
Btu/hr
592
Infiltration: 4,771 X 0.69 X 67.71 X 0.00376 =
1,684.
Air Latent CFM ELA
AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
592
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Tonkin Residence
121612018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Second Floor
Outdoor Dry Bulb Temperature
112 OF
Floor Area
1,014.00 ft'
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 75 OFI
Outdoor Dail Ran e:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btu/hr
R-36 Roof Attie Rig High Performa (N) 1,014.0 X 0,0174
X
56.0 = 988
R-21 Wall
(E) 351.7 X 0.0690
X
31.7 = 768
R-21 Wall
(S) 170.0 X 0.0690
X
27.7 = 325
R-21 Wall
(W) 378.4 X 0.0690
X
32.3 = 844
R-21 Wall
(N) 184.0 X 0.0690
X
29.0 = 368
R•19 Floor
371.0 X 0.0370
X
19.0 = 261
*R-0 Interior Surface
530.0 X 0.3560
X
0.0 = 0
X
X
=
X
X
=
Page Total 3,554
Items shown with an asterisk (*)
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF
Area
GLF Btu/hr
A!
(E) 0.0 X 10.9 +
25.0 X
19.0 = 475
(E) 0.0 X 14.5 +
40.0 X
23.5 = 941
AL
(E) 0.0 X 10.9 +
11.3 X
19.0 = 215
AM
(S) 0.0 X 10.9 +
30.0 X
12.2 = 366
51
(S) 76.0 X 14.5 +
0.0 X
15.9 = 1,100
AV
(W) 0.0 X 10.9 +
11.3 X
19.9 = 225
AT
(W) 0.0 X 10.9 +
11.3 X
19.9 = 225
AS
(W) 0.0 X 10.9 +
6.0 X
19.9 = 119
AR
(W) 0.01 X 10.9 +
6.0 X1
19.9 =1 119
Page Total 3.78
Internal Gain
Btu/hr
Occupants
3.0 Occupants X 245
Btuh/occ.
= 746
Equipment
1,014 _I Floor Area XF 0.50
w/sgft
= 1.730
Infiltration: 1.064
X 0.89 X 54.02 X 37
1.699
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
13,878
Latent Gain
Btu/hr
Occupants
3.0 Occupants X 155
Btuh/occ.
= 472
Infiltration: 4,771
X 0.89 X 54.02 X 0.00376 =
865
Air Latent
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
472
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Tonkin Residence
121612018
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Second Floor
Outdoor Dry Bulb Temperature
112 OF
Floor Area
1,014.00 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 75 OF1
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btu/hr
X
X
-
X
X
=
X
X
=
X
X
=
X
X
-
X
X
-
X
X
X
X
=
X
X
=
Page Total
Items shown with an asterisk (")
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF
Area
GLF
Btu/hr
AQ
(W) 0.0 X 10.9 +
5.0
X 19.9
= 100
AP
(W) 0.0 X 10.9 +
5.0
X 19.9
= 100
AN
(W) 0.0 X 10.9 +
5.0
X 19.9
= 100
50
(N) 0.0 X 14.5 +
68.0
X 20.3
= 1,375
49
(N) 0.0 X 14.5 +
24.0
X 20.3
= 486
X +
X
=
X +
X
=
X +
X
=
X +
X
=
Page Total
Z163
Internal Gain
Occupants
3 0 Occupants X 245
Btuh/occ.
=
Btu/hr
746
Equipment
1,014 Floor Area X 0.50
w/sgft
Infiltration: 1.064
X 0.89 X 54.02 X 37
1,898
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
13,878
Latent Gain
Btu/hr
Occupants
3 0 Occupants X 155
Btuh/occ.
w
472
Infiltration: 4,771
X 0.89 X 54.02 X 0.00376 =
865
Air Latent
CFM ELA dW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
472