Loading...
BWFE2019-008978-495 CALL TAM PICO LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Permit Type/Subtype: WALL/FENCE/CITY STANDARD/PRE-APPROVED Application Number: BWFE2019-0089 Property Address: 54085 AVENIDA MENDOZA APN: 774222023 Application Description: BIENEK / 94LF GARDEN AND 37'4"1F COMBO WALLS AT PL Property Zoning: Application Valuation: $8,500.00 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Owner: DAVID EUGENE BIENEK III 54085 AVEN I DA M EN DOZA LA QUINTA, CA 92253 Applicant: /,_`='�� Contractor: HEY DUDE CONSTRUCTION INC D [� 1— HEY DUDE CONSTRUCTION INC P0BOX 1018 PO BOX1018 THOUSAND PALMS, CA 92276 MAY 14 2019 THOUSAND PALMS, CA 92276 Ls CITY OF (.AGUINTA (760)343-5272 DESIGN & DEVELOPMENT DEPARTMENT Llc. No.: 845115 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 845115 Date: 51(4 I I!A Contractor: 1l )Ude Cr)n`, OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: () 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). () 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: Date: 5/14/2019 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Cr6 I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: ACE AMERICAN INSURANCE COMPANY Policy Number: RWCC65188041 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: � �((� Applicant:_ Af1drP,--\ 6-cr ,Cx WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. Date: 51144 111, Signature (Applicant or Agent): Ag�v Date: ' 5/14/2019 Application Number: BWFE2019-0089 Property Address: 54085 AVENIDA MENDOZA APN: 774222023 Application Description: BIENEK / 94LF GARDEN AND 37'-6"LF COMBO WALLS AT PL Property Zoning: Application Valuation: $8,500.00 Applicant: HEY DUDE CONSTRUCTION INC P 0 BOX 1018 THOUSAND PALMS, CA 92276 Owner: DAVID EUGENE BIENEK III 54085 AVENIDA MENDOZA LA QUINTA, CA 92253 Contractor: HEY DUDE CONSTRUCTION INC P 0 BOX 1018 THOUSAND PALMS, CA 92276 (760)343-5272 Llc. No.: 845115 Detail: 94LF OF 6' GARDEN WALL & PILASTERS AT THE FRONT PROP. LINE AND INTERIOR YARD LOCATIONS NOT TO ENCROACH INTO 12' PUBLIC RIGHT-OF- WAY [ANGELUS 5-1.1LQ & 5-1.9LQ SPECIFICATIONS] 37'-6"LF OF 6' COMBO WALL AT THE NORTH, AND SOUTH PROPERTY LINES [ANGELUS 5-1.51-Q & S- 1.6LQ SPECIFICATIONS] PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. THE AREA BETWEEN THE BACK OF CURB AND ANY FENCING SHALL BE LANDSCAPED, HAVE A SUITABLE PERMANENT IRRIGATION SYSTEM, AND BE CONTINUOUSLY MAINTAINED BY THE PROPERTY OWNER. 2016 CALIFORNIA BUILDING CODES. DESCRIPTION ACCOUNT CITY AMOUNT RETAINING/COMBINATION WALL EA 50LF 101-0000-42400 0 $16.01 DESCRIPTION ACCOUNT QTY AMOUNT WALL/FENCE - FIRST 100 LF 101-0000-42404 0 $53.37 DESCRIPTION ACCOUNT CITY AMOUNT WALL/FENCE - FIRST 100 LF PC 101-0000-42600 0 $66.71 Total Paid for BLOCK WALL: $136.09 DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 Property Owner's Name:�y Address: 5tjob5 k.vtf,,, kq City, ST, ZiPi_,. ['_) _ -k Telephone: Email k I New Commercial / Tenant Improvements: Total Building Construction Type 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 SF Occupancy: OFFICE USE ONLY # � Submittal � Required � Received Plan Sets Structural Calcs Truss Calcs Title 24 Calcs Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License �Let,-rQILL A L� ► v u,%Xk�e 1 � C+►n.�t,� P I TYF Vt� A BUILDING REVIEWED FOR CODE n-� 8 5'LlubS ,-4sy c-r-t-( C-� pv" V-4, I I �0�� 1211 cblvmnsl �z! 3i' G LF n3 (-' Sc,�- ,ec-N cd r) w 0, 5q 0 S S AvEN%t) A MENDOZA -- > Tv dif ANGELUS BLOCK MASONRY FENCE WALL SYSTEM DESIGN CRITERIA: 1. DESIGN CRITERIA PER 2016 CBC 2 ALLOWABLE SOIL BEARING PRESSURE = 1500psf 3. ALLOWABLE SOIL PASSIVE PRESSURE = 150pcf 4. COEFFICIENT OF FRICTION = 0.25, COHESION = Opsf 5. CANTILEVER ACTIVE = 30pcf 6. MASONRY COMPRESSIVE STRENGTH, fm = 1500psi. SPECIAL INSPECTION NOT REQUIRED PER CBC SECTION 1704.2, EXCEPTION 2, 'U' OCCUPANCY. 7. USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE PROJECT SPECIFIC SITE. NOTES: 1. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 GRADE 60. PROVIDE SPLCES (LAPS) OF 48 BAR DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER. CENTER VERTICAL BARS IN CELLS. 2. JOINT REINFORCEMENT ("LADDER" TYPE) SHALL BE COLD -DRAWN STEEL WIRE CONFORMING TO ASTM A951. PROVIDE MINIMUM 6 INCH LAP SPLICES 3. STRENGTH OF CONCRETE FOR FOOTINGS = 2500psi ® 28 DAYS, UNLESS OTHERWISE REQUIRED BY SOILS REPORT. 4. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS BLOCK PRECISION, SPLIT FACE, BURNISHER, OR SHOTBLAST, WITH OR WITHOUT MORTARLESS HEAD JOINTS (TONGUE -AND -GROOVE), OR ANGELUS BLOCK SLUMPSTONE SHALL BE USED. 5. MORTAR SHALL BE SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS MANUFACTURED BY E-2 MIX INC., CONFORMING TO PROPORTIONS AND REQUIREMENTS OF ASTM C270, OR SPEC MIX IWR MASONRY MORTAR AS MANUFACTURED BY E-2 MIX INC., CONFORMING TO PROPERTY REQUIREMENTS OF ASTM C270. 6. GROUT SHALL CONFORM TO ASTM C476. WITH AN 8-11 INCH SLUMP, AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2000ps1. 7. FIRST COURSE MAY BE WET -SET 1 1/2 INCHES MAX. WHILE CONCRETE IS PLASTIC. 8 CONCRETE BLOCK SHALL BE LAID IN RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS. 9. VERTICAL CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF 40'-D"o.c. OR 20'-O"o.c. IF WALL IS TO BE STUCCO COATED OR MORTAR WASHED 1 n. GROUT ALL CELLS WITH REINFORCEMENT. 11. INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL FOOTING REINFORCING IS TIED IN PLACE. B. AFTER VERTICAL REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT. 12. FOR TYPICAL FOOTING STEP AND DRAINAGE BLOCK -OUT DETAILS SEE DETAIL SHEET S-5.1. 13. DO NOT PLACE FOOTING WITHIN 5'-0" OF A SLOPE MASONRY FENCE WALL SCHEDULE 'H' MAX. 'X SIARS 'B' MIN. 16' LONG CMU 18" LONG CMU 6' 0' 4048"o.c. #4®54 o.c. 2'-6" 6'-B" 4(�440"o.c. 4®45"o.c. 2'-9" 7'-4" 4032"o.c. 4®36"o.c. 3'-0" 8'-0" 1 #4024"o.c. 4027"o.c. 3'-3" GHL INC. ARCHITECTURE - ENGINEERING 228 East Badillo Street 1 Covina, CA 91723 T:626.938,1595 P 626,938.0485 _ www.ghl-oe.com 6' to 8' High Site Wall Eccentric Spread Footing C a 110mph (ult.) Risk Category I 6" Wide CMU UN IIUNAL WAI STD. LADD #5 STD FOR JOINT REINF. COURSE, AT F COURSE, AND 6" WIDE (NOM GROUT CELLS w/ REINF. 'X' BARS PER SCHEDULE CTR. OF WALL DWLS. TO MAT VERT. REINF. 1 24" MIN. F.G. - WET -SET FIRS' COURSE 2-#4 CONT. CONT. CONC. F CITY OF LA QUINTA BUILDING DIVISION APPROVED FOR CONSTRUCTION BY: ADATE: 09/21/2018 PER SCHEDULE e�pF E5510 N0. 85681 i[ EXP. 9-30-20 V E OF C AL�F 4 DATE SIGNED 9-10-18 S-1.1LQ #16-077 BLOCK CO., INC. Since 1946 ANGELUS BLOCK MASONRY FENCE WALL SYSTEM DESIGN CRITERIA: 1. DESIGN CRITERIA PER 2016 CBC 2. ALLOWABLE SOIL BEARING PRESSURE = 1500psf 3. ALLOWABLE SOIL PASSIVE PRESSURE = 150pcf 4. COEFFICIENT OF FRICTION = 0.25. COHESION = Opsf 5. CANTILEVER ACTIVE = 30pcf 6. MASONRY COMPRESSIVE STRENGTH, f m = 1500psi. SPECIAL INSPECTION NOT REQUIRED PER CBC SECTION 1704.2, EXCEPTION 2, 'U' OCCUPANCY. 7. USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE PROJECT SPECIFIC SITE. NOTES: 1. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 GRADE 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER. CENTER VERTICAL BARS IN CELLS. 2. JOINT REINFORCEMENT ("LADDER" TYPE) SHALL BE COLD —DRAWN STEEL WIRE CONFORMING TO ASTM A951. PROVIDE MINIMUM 6 INCH LAP SPLICES. 3. STRENGTH OF CONCRETE FOR FOOTINGS = 2500psi ® 28 DAYS, UNLESS OTHERWISE REQUIRED BY SOILS REPORT. 4. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS BLOCK PRECISION, SPLIT FACE, BURNISHED, OR SHOTBLAST, WITH OR WITHOUT MORTARLESS HEAD JOINTS (TONGUE —AND —GROOVE), OR ANGELUS BLOCK SLUMPSTONE SHALL BE USED. 5. MORTAR SHALL BE SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS MANUFACTURED BY E—Z MIX INC., CONFORMING TO PROPORTIONS AND REQUIREMENTS OF ASTM C270, OR SPEC MIX IWR MASONRY MORTAR AS MANUFACTURED BY E—Z MIX INC., CONFORMING TO PROPERTY REQUIREMENTS OF ASTM C270, 6. GROUT SHALL CONFORM TO ASTM C476, WITH AN 8-11 INCH SLUMP, AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2000ps1. 7. FIRST COURSE MAY BE WET —SET 1 1/2 INCHES MAX. WHILE CONCRETE IS PLASTIC. 8. CONCRETE BLOCK SHALL BE LAID IN RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS. 9. VERTICAL CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF 40'—O"o.c. OR 20'-0"o.c. IF WALL IS TO BE STUCCO COATED OR MORTAR WASHED 10. GROUT ALL CELLS WITH REINFORCEMENT 11. INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL FOOTING REINFORCING IS TIED IN PLACE, B. AFTER VERTICAL REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT. 12. FOR TYPICAL FOOTING STEP AND DRAINAGE BLOCK —OUT DETAILS SEE DETAIL SHEET S-5.1. 13. DO NOT PLACE FOOTING WITHIN 5'-0" OF A SLOPE MASONRY FENCE RETAINING WALL SCHEDULE .H, 'X BARS 16' LONG CMU ly BARS 16" LONG CMU 'B' MIN. 'C' MIN. 2 —0' 4032 o.c. 4®48 o.c. 2'-4 0'-3" 2'-8" 4032"o.c. 4048"o.c. 2'-4" 0'-6" 4®48"o.c. 2'-6" 0'-9" L03-44:14032"o.c. " 1 #4@32"o.c. 4®48"o.c. 1 2'-10" GHL INC. ARCHITECTURE - ENGINEERING 228 East Badillo Street Covina, CA 91723 T: 626 9381595 F: 626 938 0485 B w 0111'3q_ nm 6' High Wall 2' to 4' Retaining Toe -out Footing C o 110mph (ult) Risk Category I 678' Wide CMU OPTIONAL WALL CAP STD. LADDER TYPE #5 STO FOR SLUMPSTONE) JOINT REINF. AT TOP COURSEr­__ AT FIRST COURSE, AND 24"o.c. AT FENCE 6" WIDE (NOM.) CMU w/ 'Y' BARS PER SCHEDULE 0 CTR, OF WALL. GROUT CELLS w/ REINF. #4 HORIZ. 024"o.c. ® RETAINING 4"0 SDR 35 PERE. PIPE w/ 1c.f. 3/4" GRAVEL WRAPPED IN MIRAFI 140N FILTER FABRIC— —� SLOPE TO DRAIN. WATERPROOF BACKSIDE OF RETAINING WALL 8" WIDE (NOM.) CMU_ FULLY GROUTED _ 'X' BARS PER SCHEDULE, LAP 24" MIN. FG WET —SET FIRST COURSE — #4 CONT. CONT. CONC. FTG. 1 CONC. KEY 12" 12" 'B' MIN. LOADING PER SCHEDULE 1. SEISMIC, 5% DAMPING ® 1 SECOND ACCELERATION Cs=0.33Wt. 2. FOUNDATION SIZES BASED ON MAXIMUM WIND OR SEISMIC LOADING. CITY OF LA QUINTA BUILDING DIVISION APPROVED FOR CONSTRUCTION BY:A. 6,t&q DATE: 09/21/2018 ' H' + 12" DISTANCE TO EDGE OF NEAREST ADJACENT FOUNDATION O X 1 a OPTIONAL CHAMFER BACKFILL— WELL GRADED, CLEAN ••SAYDS OR GRAVEL OR COMBINATION USC= GW,GP OR SW,SP 24" OUTSIDE FACE OF BLOCK TO D I. OF VERT w U to w 0- 3" CLR. b TYP. #4016"o.c. STAGGERED w/ STEM BAR FOR TYPE 'A' WALLS RETAINING 3'-4" & 4'-0" DATE SIGNED 9-10-18 S-1.5LQ #16-077 BLOCK CQ. INC. Since "1946 ANGELUS BLOCK MASONRY FENCE WALL SYSTEM DESIGN CRITERIA: 1. DESIGN CRITERIA PER 2016 CBC 2. ALLOWABLE SOIL BEARING PRESSURE = 1500psf 3. ALLOWABLE SOIL PASSIVE PRESSURE = 150pcf 4. COEFFICIENT OF FRICTION = 0.25, COHESION = Opsf 5. CANTILEVER ACTIVE = 30pcf 6. MASONRY COMPRESSIVE STRENGTH, fm = 1500psi. SPECIAL INSPECTION NOT REQUIRED PER CBC SECTION 1704.2, EXCEPTION 2, 'U' OCCUPANCY. 7. USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE PROJECT SPECIFIC SITE. 1. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 GRADE 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER. CENTER VERTICAL BARS IN CELLS. 2. JOINT REINFORCEMENT ("LADDER" TYPE) SHALL BE COLD —DRAWN STEEL WIRE CONFORMING TO ASTM A951. PROVIDE MINIMUM 6 INCH LAP SPLICES. 3. STRENGTH OF CONCRETE FOR FOOTINGS = 2500psi ® 28 DAYS, UNLESS OTHERWISE REQUIRED BY SOILS REPORT. 4. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS BLOCK PRECISION, SPLIT FACE, BURNISHED, OR SHOTBLAST, WITH OR WITHOUT MORTARLESS HEAD JOINTS (TONGUE —AND —GROOVE), OR ANGELUS BLOCK SLUMPSTONE SHALL BE USED. 5. MORTAR SHALL BE SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS MANUFACTURED BY E—Z MIX INC., CONFORMING TO PROPORTIONS AND REQUIREMENTS OF ASTM C270, OR SPEC MIX IWR MASONRY MORTAR AS MANUFACTURED BY E—Z MIX INC., CONFORMING TO PROPERTY REQUIREMENTS OF ASTM C270. 6. GROUT SHALL CONFORM TO ASTM C476, WITH AN B-11 INCH SLUMP, AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2000psi. 7. FIRST COURSE MAY BE WET —SET 1 1/2 INCHES MAX. WHILE CONCRETE IS PLASTIC. 8. CONCRETE BLOCK SHALL BE LAID IN RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS. 9. VERTICAL CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF 40'—O"o.c. OR 20'-0"o.c. IF WALL IS TO BE STUCCO COATED OR MORTAR WASHED 10_ GROUT ALL CELLS WITH REINFORCEMENT, 11. INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL FOOTING REINFORCING IS TIED IN PLACE. B. AFTER VERTICAL REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT. 12. FOR TYPICAL FOOTING STEP AND DRAINAGE BLOCK —OUT DETAILS SEE DETAIL SHEET S-5.1. 13. DO NOT PLACE FOOTING WITHIN 5'-0" OF A SLOPE MASONRY FENCE RETAINING WALL SCHEDULE 'H, 'X' BARS 16" LONG CMU ''Y' BARS 16" LONG CMU •B' MIN. 'C' MIN. 2 —0 4®32"o.c. 4®48"o.c. 2 —9 N A 2'-8" 3'-0" N/A 3'-4" 4032"o.c. 4®48"o.c. 3'-5" N A 4' O" 4®32"o.c. 4®48"o.c. 3'-11" 0' 2" GHL INC. ARCHITECTURE - ENGINEERING 228 East Badillo Street 1 Covina, CA 91723 T: 626 938.1595 F: 626 938 0485 _ Vwvw ghlve C1un 6' High Wall 2' to 4' Retaining Heel -in Footing C o 110mph (ultj Risk Category I 678" Wide CMU OPTIONAL WALL CAP STO. LADDER TYPE 05 STD FOR SLUMPSTONE) JOINT REINF. AT TOP COURSE, - AT FIRST COURSE, AND 24"o.c. AT FENCE 6" WIDE (NOM.) CMU w/ 'Y' BARS PER SCHEDULE 0 CTR. OF WALL. GROUT CELLS w/ REINF. #4 HORIZ. 024"o.c. ® RETAINING 4"0 SDR 35 PERF. PIPE w/ 1c.f. 3/4" GRAVEL WRAPPED IN MIRAFI 14ON FILTER FABRIC— - SLOPE TO DRAIN. WATERPROOF BACKSIDE OF RETAINING WALL 8" WIDE (NOM.) CMU FULLY GROUTED _ 'X' BARS PER SCHEDULE, LAP 24" MIN. F.G. - WET —SET FIRST ? COURSE #4 CONT. #4 CONT. ® 12"o.c- CONT. CONC. FTG. — CONC. KEY LOADING 1. SEISMIC, 5% DAMPING ® 1 SECOND ACCELERATION Cs=0.33Wt. 2. FOUNDATION SIZES BASED ON MAXIMUM WIND OR SEISMIC LOADING. CITY OF LA QUINTA BUILDING DIVISION APPROVED FOR CONSTRUCTION BY:A. 09/21/2018 U to H' + 12" DISTANCE TO EDGE OF NEAREST ADJACENT FOUNDATION O X I m � OPTIONAL CHAMFER BACKFILL— WELL GRADED, CLEAN SANDS OR GRAVEL OR COMBINATION USC= GW,GP OR SW,SP 2}" OUTSIDE FACE Ld OF BLOCK TO C OF VERT w 12" 1 12" 'B' MIN. PER SCHEDULE DATE SIGNED 9-10-18 S-1.6LQ #16-077 =1x U N (J of rjfioA 9L0CKCCk,1NC. nce 1946 ANGELUS BLOCK MASONRY FENCE WALL SYSTEM DESIGN CRITERIA: 1. DESIGN CRITERIA PER 2016 CBC 2. ALLOWABLE SOIL BEARING PRESSURE = 1500psf 3. ALLOWABLE SOIL PASSIVE PRESSURE = 150pcf 4. COEFFICIENT OF FRICTION = 0.25, COHESION = Opsf 5. CANTILEVER ACTIVE = 30pcf 6. MASONRY COMPRESSIVE STRENGTH, fin = 1500psi SPECIAL INSPECTION NOT REQUIRED PER CBC SECTION 1704.2, EXCEPTION 2, 'U' OCCUPANCY. 7. USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE PROJECT SPECIFIC SITE. NOTES: 6'-8" to 8'-8" High Pilaster Spread Footing Seismic, 5% o 1 second 16" or 240 CMU Pilaster OPTIONAL WALL CAP CMU PILASTER, SOLID GROUT (16" SHOWN) 1. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 GRADE 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER. CENTER VERTICAL BARS IN CELLS. 3j"OUTSIDE FACE 2. NOT USED. OF BLOCK TO Ct OF VERT 3. STRENGTH OF CONCRETE FOR FOOTINGS = 2500psi ® 28 DAYS, UNLESS OTHERWISE REQUIRED BY SOILS REPORT. 4. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS 2-#4 VERT. BARS BLOCK PRECISION, SPLIT FACE, BURNISHED, OR SHOTBLAST, OR ANGELUS BLOCK SLUMPSTONE SHALL BE USED. �► 5. MORTAR SHALL BE SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS MANUFACTURED BY E-Z MIX INC., CONFORMING TO PROPORTIONS AND REQUIREMENTS OF ASTM C270, OR SPEC MIX IWR MASONRY MORTAR AS MANUFACTURED BY E-Z MIX INC., CONFORMING TO PROPERTY REQUIREMENTS OF ASTM C270. 6. GROUT SHALL CONFORM TO ASTM C476, WITH AN 8-11 INCH SLUMP, AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2000psi. 7. FIRST COURSE MAY BE WET -SET 1 1/2 INCHES MAX. WHILE CONCRETE IS PLASTIC. 8. NOT USED. 9. PROVIDE EXPANSION / CONTROL JOINT ON EACH SIDE OF PILASTER WHERE INTERSECTING BLOCK WALLS OCCUR. 10. NOT USED. 11. INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL FOOTING REINFORCING IS TIED IN PLACE. B. AFTER VERTICAL REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT. 12. OPTIONAL ADHERED VENEER (MAX WEIGHT=10psf) MAY BE APPLIED TO EACH FACE OF PILASTER. INSTALLATION BY OTHERS. MECHANICALLY -ANCHORED VENEER IS NOT PERMITTED. 11 DO NOT PLACE FOOTING WITHIN 5'-0" OF A SLOPE 16816 OR 16616 CMU MASONRY PILASTER SCHEDULE PILASTER, SOLID GROUT H' 'V MAX. 1 13' N' 6'-8" 16 2 -9 4 24" 3'-4" 5 7'-47 16" 3'-0" 4 24" 3'-6" 5 16" 31-3" 5 24" 4'-0" 6 LOADING 1. SEISMIC, 5% DAMPING ® 1 SECOND ACCELERATION Cs=0.33Wt. 2. SEISMIC LOADING EXCEEDS ALL WIND LOADING FOR EXPOSURE C, 130mph AND LESS. ,W,� w d d w 2-#4 d w w GHL INC. ARCHITECTURE - ENGINEERING 228 East Badillo Street I Covina, CA 91723 T: 626,938,1595 F: 626,93&0485 = www.ghlbe.com OWLS. TO MATCH VERT. REINF. LAP 24" MIN. 3j"OUTSIDE F4CE OF BLOCK TO t OF VERT EQ. EQ. F. G. a� WET -SET FIRST COURSE - 'N'- LONG EA. WAY CONC. FTG. B' SQUARE MIN. PER SCHEDULE 8" WIDE (NOM.) CMU PILASTER, SOLID GROUT ALL CELLS CENTER VOID OPEN OR SOLID -GROUT 'W'=24" SQ. A PILASTER SECTION i� 3" CLR. TYP. CITY OF LA QUINTA BUILDING DIVISION APPROVED FOR CONSTRUCTION BY: A. DATE: 09/21/2018 C� 7 h NO. 85 81 ♦c EXP. 9-30-20 C / V' d OF CA��FO DATE SIGNED 9-10-18 S-1.9LQ #16-077 w J