Loading...
05-1556 (CSCS) Revision 1Bin y of La uinta City,Q 1/I St?0�t S _/® Building U Safety Division Permit # P.O. Box 1504, 78-495 Calle Tampico �15362vls/r`JHs `p pec �� La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Project Address: y6,,, -v d e.5—^ Owner's Name: L,Zi 4r A. P. Number: Address: �U 6de Legal Description: City, ST, Zip: `� Q xi 92, Contractor: Telephone:• r ` Address: Project Description: City, ST, Zip: Dee. z Telephone: State Lic. # : City Lic. #: Arch., Engr., Designer: Address: City, ST, Zip: Telephoner �'- Construction Type: Occupancy: N q State Lic. #: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person:��// Sq. Ft.: #Stories: # Units: Telephone # of Contact Person: Estimated Value of Project:- APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES 3 Plan Sets Plan Check submitted Item Amount --77 l� Structural Calcs. Reviewed, ready for corrections Z b Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy Calcs. Plans picked up Construction Flood plain plan Plans resubmitted 11 '�j til/ Mechanical Grading plan' 2"" Review, ready for correctionsfissue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted . i Grading IN ROUSE:- ''" Review, ready for corrections/issue Developer Impact Fee . Planning Approval Called Contact Person AJ. P. Pub. Wks. Appr Date of permit issue ) �� School Fees Total Permit Fees 1012- 0(D -"� ESGI L OUE : i 0 13 OCo 1ol21oc0� cooC�i6�t� %b/� +/.r -9 wl-t odoX1A to- Iav ea:-GiL p PROVED� (�paov� ��bb. ON �b Title 24 Report for:. Washington Park—P_ad_4 6=48.0 Washingtn Street LaQuina CA 92253; • CITY �F A BUILDING & SAFEETY DEpA �A , APPROVED OR CONSTRUCTION T. Project Designer: DATE is e6gYic KKE Architects, Inc, vis.eti, 20321 SW Birch Street, Suite 20 Newport Beach, CA 92660 (949) 250-3911 Report Prepared By: SIA GARESTANI, P.E. SPEC Engineering 6800 Owensmouth Ave. #140 Woodland Hills, CA 91303 (818) 5921-6643 FSPEC :Engineering: OVE Job Number: DEC 14 2006 05-088 Date: 12/5/2006 x The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 897-6400. EnergyPro 3.1 By EnergySoft Job Number: 05-088 User Number: 3358 J TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Nonresidential Performance Title 24 Forms r 3 Form ENV-MM Envelope Mandatory Measures 11 Form MECH-MM Mechanical Mandatory Measures 12 HVAC System Heating and Cooling Loads Summary 14 Room Load Summary 16 Room Heating Peak Loads 18 Room Cooling Peak Loads 20 Room Cooling Coil Loads 22 EnergyPro 3.1 By EnergySoft Job Number: 05-088 User Number: 3358 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 PROJECT NAME This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and DATE Washington Park - Pad 4 BUILDING CONDITIONED FLOOR AREA 2,973 Sq.Ft. 12/5/2006 PROJECT ADDRESS - - 46-480 Washingtn Street La Quinta for this permit application are consistent with all other forms and >�W sheets, specifications, and other calculations submitted with this ADDITION [:] ALTERATION EXISTING + ADDITION PRINCIPAL DESIGNER - ENVELOPE TELEPHONE Building Permit #' KKE Architects, Inc (949) 250-3911 ❑ ❑ [:1 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section DOCUMENTATION AUTHOR TELEPHONE Checked by/Date SPEC Engineering (818) 592-6643 EriforcementAgency Use GENERAL INFORMATION This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Building using therformapfte compliance approach. DATE OF PLANS 04-01-05 BUILDING CONDITIONED FLOOR AREA 2,973 Sq.Ft. CLIMATE ZONE 15 BUILDING TYPE 191NONRESIDENTIAL HIGH RISE RESIDENTIAL HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION NEW CONSTRUCTION for this permit application are consistent with all other forms and >�W sheets, specifications, and other calculations submitted with this ADDITION [:] ALTERATION EXISTING + ADDITION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Building using therformapfte compliance approach. DOCUMENTATION AUTHOR SIGNATURE DATE SIA GARESTANI P.E. 121512006 The Principal Designers hereby certify that the proposed building g re nted in the construction documents and modelled for this permit application are consistent with all other forms and >�W sheets, specifications, and other calculations submitted with this permit application. The proposed building as designed meet a energy efficiency requirements of the State Building Code, Title 24, Part 6. ENV. LTG. MECH. LXJ 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, mechanical engineer, electrical engineer or architect. ❑ ❑ [:1 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing documents for work that I have contracted to perform. F ❑ F] 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pusuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code ae printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures NV -1 Required For PRINCIPAL ENVELOPE DESIGNER - NAME SIGNATURE ILIC. NO. DATE KKE Architects Inc C.-2:770 II Z o Ob LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Lighting Compliance Not In The Scope Of ThIS—Submittal Required Forms PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE LIC. NO. DATE MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures N4FCECH-2,MECH-3 Required Forms PRINCIPAL MECHANICAL DESIGNER -NAME SIGNATURE LIC. NO. DATE SIA GARESTANI, P.E. I M26426 121512006 I EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number: 05-088 Page:3 of 23 1 PERFORMANCE CERTIFICATE OF. COMPLIANCE Part 2 of 3 ' PERF -1 DATE Washin ton Park - Pad 4 �' 12/5/2006 ANNUAL SOURCE ENERGY USE SUMMARY kBtu/s ft- r Standard Proposed Compliance ENERGY COMPONENT Design Design Margin s�ndam_:erovoaea , Space Heating _3.43 2.02 1.41 � � ��a� ' " y ~ • Space Cooling 93.44 88.19 5.25 °° ' ' 5` � Indoor Fans 15.64 17.66 .y Yet -2.02 "°°� .' t ` �'�: •' Heat Rejection 0.00 ' 0.00 ,, 0.00 Pumps & Misc. 0.00 0.00 0.00 Domestic Hot Water 12.01 + 11.30 r 0.71 Lighting 39.15 39.15 0.00 Receptacle ; , . 25.43 � 25.43 Recap e `t sis` a -• •"1.. 0.00 '°.• tli ' f Process 84.66 84.66 0.00 ' • -- 20, + 0 0 1:.. s30.40 50 Trao 70 80 HBO'` TOTALS: 273.76 268.42 . + 5.35 ke'`wisgti-yr '« Percent better than Standard: 2.0% ( 2.8% excluding process) BUILDING COMPLIES GENERAL INFORMATION Building Orientation Southwest 225 deg Conditioned Floor Area. 2,973 sqft. Number of Stories 1 Unconditioned Floor Area 2,472 sqft. Number of Systems -3 Conditioned Footprint Area 0 sqft. Number of Zones , 3 Orientation . Gross Area Glazing Area Glazing Ratio , Front Elevation (Southwest 795 sqft. .310 sqft. 39.0% - Left Elevation (Northwest 928 sqft. 399 sqft. 43.0% Rear Elevation ' . Northeast 795 sqft. 69 sqft. 8.7% Right Elevation " (Southeast) +0 sgft-' 0 sqft. 0.0% Total 2,518 sqft. 778 sqft. 30.9% •" Roof ' 2,673 sqft .sqft. 0.0% ' Standard Proposed +LERP Energy -8 Atmosphere_Credit. Lighting Power Density 1.330 w/sgft. 1.330 w/sgft. Savings vs. Title 241 3.27% Prescriptive Env. Heat Loss 697 Btu/h 1,143 Btu/h Energy Performance Credit2 0 Points Prescriptive Env. Heat Gain 84,807 Btu/h-F 124,338 Btu/h-F 1. excludes process and receptacle 2. see LEED table 8c or 8-d Remarks: Run Initiation Time: 12/05/06 16:46:40 Run Code: 1165366000 EnergyPro 3.1 By EriergySoft User Number: 3358 Job Number: 05-088 PageA of 23 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 PROJECT NAME DATE Washington Park - Pad 4 12/5/2006 justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted- '1 The Zone "Zone 1" has a Display Perimeter Credit of 46 ft.' , The Zone "Zone 2" has a Display Perimeter Credit of 28 ft. The Zone "Zone 3 Future Retail)" has a -Display Perimeter Credit of 27 ft. 4 The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. • • . .'fit � •1 . t ' �k _ Authorized Signature or Stamp Run Initiation Time:' 12/05/06 16:46:40 Run Code: 1165366000 EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number: 05-088 Page:5 of 23 ,max � � } ,� .• 'r., `� - ENVELOPE COMPLIANCE SUMMARY Performance ENV -1 PROJECT NAME Washington Park - Pad 4 SH.GC Glazing Type Location / Comments DATE 12/5/2006 OPAQUE SURFACES 225 0.82 Sin le Clear Default NM one 1 2 Window Surface Framing Act.Gains # Type Type Area U -Fac. Azm. Solar - Tilt Y/N Form 3 Reference Location / Comments 1 Roof Wood 1 403 0.035 0 0 X11 R-30 Roof R.30.2x12.16 Zone 1 2 Wall Wood 213 0.065 225 90 X11 R-19 Wall W.19.2x6.16 Zone 1 3 Wall Wood 299 0.065 45 90 X R-19 Wall W.19.2x6.16 Zone 1 4 Wall Wood 529 0.065 315 90 R-19 Wall W.19.2x6.16 Zone 1 5 Roof Wood 1,570 0.035 0 0 X R-30 Roof R.30.2x12.16) Zone 2 6 Wall Wood 427 0.065 45 90 X R-19 Wall W.19.2x6.16 Zone 2 7 Wall Wood 272 0.065 225 90 X R-19 Wall W.19.2x6.16 Zone 2 8 Roof Wood 2,472 0.035 0 0 X R-30 Roof R.30.2x12.16 Zone 3 Future Retail 9 Wall Wood 1,014 0.065 135 1 90 x I I R-19 Wall W.19.2x6.16 Zone 3 Future Retail 10 Wall Wood 519 0.065 45 1 90 X I I R-19 Wall (W.19.2x6.16) Zone 3 (Future Retail) 11 Wall Wood 390 0.065 225 90 X R-19 Wall W.19.2x6.16 Zone 3 Future Retail EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Len, Hgt, LExt.RExt. Dist, Left Fin Right Fin Len.Dist, L 1 None 0.76 14.2 14.0 6.0 0.1 6.0 6.0 2 None 0.76 8.7 8.0 6.0 0.1 6.0 6.0 3 None 0.76 14.2 14.0 6.0 0.1 6.0 6.0 4 None 0.76 14.0 6.0 6.0 0.1 6.0 6.0 5 None 0.76 8.0 17.0 6.0 0.1 6.0 6.0 6 None 0.76 14.2 14.0 6.0 0.1 6.0 6.0 7 None 0.76 10.5 3.7 1.0 0.1 1.0 1.0 8 None 0.76 7.5 6.0 1.0 0.1 1.0 1.0 9 None 0.76 10.5 3.7 1.0 0.1 1.0 1.0 10 None 0.76 10.0 3.7 FENESTRATION SURFACES 0.1 11.0 11.0 11 None 0.76 10.0 Site Assembled Glazing U t,necK Dox it rsunaing is - iuu,uuu sgrr or crA and - 1u,uuu sqtt vertical glazing then NFRC Certification is required. Follow NFRC 100 -SR PrnrP.d11rP9 and cuhmit NERC I nhPl r.ar ifirnte Fnrm # Type Area U -Fac. Act. Azm. SH.GC Glazing Type Location / Comments 1 Window 155 1.190 225 0.82 Sin le Clear Default NM one 1 2 Window 69 1.190 45 0.82 Single Clear Default NM one 1 3 Window 155 1.190 315 0.82 Sin le Clear Default NM one 1 4 Window 97 1.190 315 0.82 Sin le Clear Default NM one 1 5 Window 147 1.190 315 0.82 Single Clear Default NM one 1 6 Window 155 1.190 1 225 0.82 Single Clear Default NM one 2 7 Window 38 1.190 45 0.82 Single Clear Default NM one 3 Future Retail 8 Window 45 1.190 45 0.82 Single Clear Default NM one 3 Future Retail 9 Window 38 1.190 45 0.82 Single Clear Default NM one 3 Future Retail 10 Window 37 1.190 225 0.82 Sin le Clear Default NM one 3 Future Retail 11 Window 60 1.190 225 0.82 Single Clear Default NM one 3 Future Retail 12 Window 37 1.190 225 0.82 Single Clear Default NM one 3 Future Retail 13 Window 37 1.190 225 0.82 Single Clear Default NM one 3 Future Retail 14 Window 42 1.190 225 0.82 Single Clear Default NM one 3 Future Retail 15 Window 37 1.190 225 0.82 Single Clear Default NM one 3 Future Retail EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Len, Hgt, LExt.RExt. Dist, Left Fin Right Fin Len.Dist, L 1 None 0.76 14.2 14.0 6.0 0.1 6.0 6.0 2 None 0.76 8.7 8.0 6.0 0.1 6.0 6.0 3 None 0.76 14.2 14.0 6.0 0.1 6.0 6.0 4 None 0.76 14.0 6.0 6.0 0.1 6.0 6.0 5 None 0.76 8.0 17.0 6.0 0.1 6.0 6.0 6 None 0.76 14.2 14.0 6.0 0.1 6.0 6.0 7 None 0.76 10.5 3.7 1.0 0.1 1.0 1.0 8 None 0.76 7.5 6.0 1.0 0.1 1.0 1.0 9 None 0.76 10.5 3.7 1.0 0.1 1.0 1.0 10 None 0.76 10.0 3.7 11.0 0.1 11.0 11.0 11 None 0.76 10.0 6.0 11.0 0.1 11.0 11.0 12 None 0.76 10.0 3.7 11.0 0.1 11.0 11.0 13 1 None 0.76 10.0 3.7 11.0 0.1 11.0 11.0 14 None 0.76 7.0 6.0 11.0 0.1 11.0 11.0 15 None 0.76 10.0 3.7 11.0 0.1 11.0 11.0 Run i io Time: 12/05/06 16:46:40 Run Code: 1165366000 EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number: 05-088 Page:6 of 23 71, CERTIFICATE OF COMPLIANCE ♦' Performance . MECH-1 PROJECT NAME r DATE Washington Park - Pad 4 12/5/2006 SYSTEM FEATURES MECHANICAL SYSTEMS SYSTEM NAMENOTE TO DHW Heater + RTU -1,2 RTU -3 ` FIELD r r. e DIY'• TIME CONTROL ' SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL r VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH-3, COLUMN I HEATING EQUIPMENT TYPE. HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER � PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION R -VALUE COOLING DUCT LOCATION R -VALUE VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE n/a ' n/a n/a n/a n/a n/a n/a n/a, n/a. n/a n/a . n/a n/a " n/a. n/a. Electric Res 98% n/a - n/a CHRONOMITE S-30 I -P Yes A Yes n/a n/a n/a n/a n/a Programmable Switch Heating 8 tooling Required n/a Yes + .0.0 kW „. Constant Volume .No No Constant Tem Constant Temp ; n/a Air Balance Auto No Economizer 478 cfm - Heat Pum 8.00 HSPF Packaged DX - 12.0 SEER / 10.6 EER CARRIER 50HJQ005 Yes - No Ducts in Attic 4.2 Ducts in Attic 4.2 No' Programmable Switch Heatin & Cooling Required n/a Yes. 0.0 kW ConstantVolume r No No Constant Tem Constant Tem n/a Air Balance • Auto No Economizer 336 cfm Heat Pum 3.40 COP Packaged DX 10.5 EER CARRIER 50HJ0007 1 Yes No Ducts in Attic 4.2 Ducts in Attic - No CODE TABLES: Enter code from table below Into columns above. n/a ' n/a n/a n/a n/a n/a n/a n/a, n/a. n/a n/a . n/a n/a " n/a. n/a. Electric Res 98% n/a - n/a CHRONOMITE S-30 I -P Yes A Yes n/a n/a n/a n/a n/a Programmable Switch Heating 8 tooling Required n/a Yes + .0.0 kW „. Constant Volume .No No Constant Tem Constant Temp ; n/a Air Balance Auto No Economizer 478 cfm - Heat Pum 8.00 HSPF Packaged DX - 12.0 SEER / 10.6 EER CARRIER 50HJQ005 Yes - No Ducts in Attic 4.2 Ducts in Attic 4.2 No' Programmable Switch Heatin & Cooling Required n/a Yes. 0.0 kW ConstantVolume r No No Constant Tem Constant Tem n/a Air Balance • Auto No Economizer 336 cfm Heat Pum 3.40 COP Packaged DX 10.5 EER CARRIER 50HJ0007 1 Yes No Ducts in Attic 4.2 Ducts in Attic - No CODE TABLES: Enter code from table below Into columns above. Programmable Switch Heating 8 tooling Required n/a Yes + .0.0 kW „. Constant Volume .No No Constant Tem Constant Temp ; n/a Air Balance Auto No Economizer 478 cfm - Heat Pum 8.00 HSPF Packaged DX - 12.0 SEER / 10.6 EER CARRIER 50HJQ005 Yes - No Ducts in Attic 4.2 Ducts in Attic 4.2 No' Programmable Switch Heatin & Cooling Required n/a Yes. 0.0 kW ConstantVolume r No No Constant Tem Constant Tem n/a Air Balance • Auto No Economizer 336 cfm Heat Pum 3.40 COP Packaged DX 10.5 EER CARRIER 50HJ0007 1 Yes No Ducts in Attic 4.2 Ducts in Attic - No CODE TABLES: Enter code from table below Into columns above. Programmable Switch Heatin & Cooling Required n/a Yes. 0.0 kW ConstantVolume r No No Constant Tem Constant Tem n/a Air Balance • Auto No Economizer 336 cfm Heat Pum 3.40 COP Packaged DX 10.5 EER CARRIER 50HJ0007 1 Yes No Ducts in Attic 4.2 Ducts in Attic - No CODE TABLES: Enter code from table below Into columns above. CODE TABLES: Enter code from table below Into columns above. MECHANICAL EQUIPMENT SUMMARY Part 1 of 2 MECH-2 PROJECT NAME Washington Park - Pad 4 v� DATE 12/5/2006 CHILLER AND TOWER SUMMARY System Name Efficiency Tons PUMPS BHP Motor Eff. Equipment Name Equipment Type Qty. Tot. Qty GPM BHP Motor Eff. Drive Eff. Pump Control 0.12 77.0% 97.0% none CARRIER 50HJ0007 Constant Volume Draw -Through 2,400 0.40 77.0% 97.0% none _I DHW BOILER SUMMARY Energy Factor or Recovery . Efficiency Standby Loss or Pilot TANK INSUL. System Name System Type Distribution Type Qty Rated Input (Gals.) Vol. Ext. R -Val. CHRONOMITE S-30 LP Instant Elec Standard 2 91429 0 0.98 n/a n/a CENTRAL SYSTEM RATINGS HEATING COOLING System Name System Type Qty. Output Aux. kW Eff. Output Sensible Efficiency Economizer Type_ CARRIER 50HJ0005 Packaged DX 2 46,000 0.0 8.00 HSPF 47,400 32,80012.0 SEER / 10.6 EER No Economizer CARRIER 50HJQ007 Packaged DX 1 69,000 0.0 3.40 COP 76,000 56,40010.5 EER No Economizer CENTRAL SYSTEM FAN SUMMARY SWF PLY FAN _RETURN FAN_ System Name Fan Type _ Motor Location CFM BHP Motor Eff. Drive Eff. CFM BHP Motor Eff. Drive Eff. CARRIER 50HJQ005 Constant Volume Draw -Through 1,600 0.12 77.0% 97.0% none CARRIER 50HJ0007 Constant Volume Draw -Through 2,400 0.40 77.0% 97.0% none I EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number: 05-088 Page:8 of 23 1 MECHANICAL EQUIPMENT SUMMARY. Part 2 of 2 MECH-2 PROJECT NAME Washinciton Park - Pad 4 DATE 12/5/2006 ZONE TERMINAL SUMMARY VAV TERMINAL BOX TERMINAL FAN Min. CFM Reheat Coil Motor Drive S stem Tvoe Oty. Ratio —Type DeltaT CFM BHP Eff. Eff. Type Output EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number: 05-088 Page:9 of 23 HAUSTFAN EXHAUSTFAN Room Name Qty. I CFM BHP Motor Eff. Drive Eff. Room Name Qty. CFM BHP Motor Eff. Drive Eff. Zone 1 1.0 100 0.20 77.0°/ 97.0% EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number: 05-088 Page:9 of 23 MECHANICAL VENTILATION MECH-3 PROJECT NAME - DATE Washington Park - Pad 4 12/5/2006 MECHANICAL VENTILATION a ©© o o a© a a a o AREA BASIS COND. MIN. ZONE/SYSTEM AREA CFM CFM (SF) PER SF (B x C) Zone 1 RTU -1,2 Zone 2 RTU -3 1,403 0.23 323 1,570 0.40 628 OCCUPANCY BASIS NO. OF PEOPLE CFM PER PERSON MIN. CFM (ExF) 31.9 15.0 478 TRANS. (MAX OF Total 22.4 15.0 336 REQ'D DESIGN O.A. OUTDOOF VAV TRANS. (MAX OF AIR MIN. FER D OR G) CFM RATIO AIR 478 478 628 628 478 478 336 336 292 C Minimum Ventilation Rate per Section 121, Table 1-F. E Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. I Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. K Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H -J). EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number: 05-088 Page:10 of 23 1 ENVELOPE MANDATORY MEASURES PROJECT NAME Washington Park - Pad 4 A ENV -MM DATE 12/,' DESCRIPTION Resig nerL Enforcement §118(.) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. ❑X § 118(.) All Insulating Materials shall be installed in compliance with the flame spread rating I and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. § 117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. R § 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). I X] § 116(a)1 Manufactured boors and Windows installed shall have air infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured , fenestration products must be labeled for U -value according to NFRC procedures. R § 118(e) Demising Walls in Nonresidential Buildings: ' The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value of no less than R-11 between framing members. _ t - 3 EnergyPro 3.1 By EnergySoft User Number: 3358 ` Job Number: 05-088 Page:11 of 23 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM PROJECT NAME DATE Washington Park - Pad 4 12/5/2006 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies t ❑X . §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. 0 § 115(a) Fan type central furnaces shall not have a pilot light. X❑ § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. X❑ § 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 603 and 604 of the Uniform Mechanical Code. Controls § 122(e)1 Each space conditioning system shall be installed with one of the following: X] § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or FX], § 122(e)16 An occupancy sensor to control the operating period of the system; or ❑X § 122(e)1C A 4 -hour timer that can be manually operated to control the operating period of the system. RX § 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint.. { § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall. be provided with Isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply ' of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above., § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be -adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. RX § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. § 112(b) Heat pumps shall be installed with controls to prevent electric resistance ' supplementary heater operation when the heating load can be met by the heat pump alone. r EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number: 05-088 Page: 12 of 23 MECHANICAL MANDATORY MEASURES PROJECT NAME Washington Park Pad 4 Part 2 of 2 MECH-MM DATE - 12/5/2006 ' Description - Designer Enforcement Ventilation n§ 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at / the ventilation rates as specified on these plans. n § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown_ shall be provided on the outside -air intakes and discharges of all space conditioning and exhaust systems. X❑ § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air , openings. 0 § 121(f)l Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or i Associated Air Balance Council (AABC) National Standards (1989); or § 121(g2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the Installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the . person with overall responsibility for the design of the ventilation system; or ❑ § 121(83 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on_a readily accessible display divice; or §121(q4 Another method approved by the Commission. I Service Water Heating. Systems JAI § 113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. . X❑ § 113(b)3B Lavatories 1n restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. X❑ § 113(b)3C Lavatories in restrooms of public facilities shall be equipped with one of the following: ' Outlet devices that limit the flow of hot water to a maximum"of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per, minute. Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). EnergyPro 3.1 By EnergySoft " User Number: 3358 Job Number: 05-088 Page:13 of 23 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Washington Park - Pad 4 12/5/2006 SYSTEM NAME FLOOR AREA RTU -1,2 1,403 24.0 OF — ) ;4 Outside Air 478 cfm 69.4 of R7 R OF LOAD Total Room Loads sturn Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts OTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM I Sensiblel Latent I ensible 5,268 108,058 6,058 245 39,478 0 5,403 1,974 0 0 F—'478 17,265 10,846 478 23,457 0 0 5,403 1,974 136,128 16,904 1 66,883 HVAC EQUIPMENT SELECTION CARRIER 50HJQ005 73,307 11,241 57,991 Total Adjusted System Output 73,307 11,241 57,991 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 5 pm an 12 am ream Temperatures at Time of Heatina Peak1 105,00F Heating Coil Supply Fan 3200 cfm 105.0 of -.,�Supply Air Ducts 104.4 of ROOMS 70.0 OF Return Air Ducts I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 109.0 / 77.8 OF 80.6 / 64.3 OF 55.0 / 53.5 OF 55.0 / 53.5 OF Outside Air Supply Air Ducts 478 cfm Cooling Coil Supply Fan 56.6 / 54.2 of 3200 cfm 48,5% R.H. ROOMS 75.6/61.9°F 74.0/61.3OF o„a...., n :. n....... E I EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number: 05-088 Page:14 of 23 ■� HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Washington Park - Pad 4 12/5/2006 SYSTEM NAME FLOOR AREA RTU -3 1,570 Number of Systems 1 Heating System Output per System 69,000 Total Output (Btuh) 69,000 Output (Btuh/sqft) 43.9 Cooling System Output per System 76,000 Total Output (Btuh) 76,000 Total Output (Tons) 6.3 Total Output(Btuh/sgft) 48.4 Total Output (sgft/Ton) 247,9 Air System CFM per System 2,400 Airflow (cfm) 2,400 Airflow (cfm/sgft) 1.53 Airflow (cfm/Ton) 378.9 Outside Air (%) 14.0 Outside Air (cfm/sgft) 0.21 Note: values above aiven at ARI conditions 24.0 OF Outside Air 336 cfm RICS R1 "OC Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 3,325 68,209 4 347 13,097 0 3,410 655 0 0 336 12,990 7,636 336 16,615 0 0 3,410 655 88,1071 11,898 31 022 CARRIER 50HJQ007 62,472 4,410 43,493 Total Adjusted System Output 62,472 4,410 43,493 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 4 pm Jan 12 am tream Temperatures at Time of Heating Peak) 105.0 °F 105.0 OF e Supply Air Ducts Heating Coil Supply Fan 104.7 °F 2400 cfm ROOMS 69.7 OF 70.0 OF Return Air Ducts 1000LING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 111.1 / 78.3 OF 80.3 / 64.1 °F 55.0 / 53.5 OF 55.0 / 53.5 OF Outside Air O Supply Air Ducts 336 cfm Cooling Coil Supply Fan 56.3 / 54.1 OF 2400 cfm 48.4% R.H. ROOMS 75.3/61.7 °F 74.0 / 61.3 OF Return Air Ducts I EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number: 05-088 Page: 15 of 23 ROOM LOAD SUMMARY PROJECT NAME Washington Park - Pad 4 DATE 12/5/2006 SYSTEM NAME RTU -1,2 FLOOR AREA 1,403 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 1 Zone 1 1 5,268 108,058 6,058 5,268 108,058 6,058 1,045 39,478 PAGE TOTAL 1 5,268 108,058. 6,058 1,045 39,478 TOTAL 1 5,268 108,058 6,058 1,045 39,478 EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number: 05-088 Page:16 of 23 ROOM LOAD SUMMARY I PROJECT NAME Washington Park - Pad 4 DATE 12/5/2006 SYSTEM NAME RTU -3 FLOOR AREA 1,570 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM I SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 2 Zone 2 1 3,368 69,075 4,261 3,325 68,209 4,261 347 13,097 PAGE TOTAL 1 3,325 68,209 4,261 TOTAL 3,325 68,209 4,261 .347 13,097 347 13,097 EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number: 05-088 Page: 17 of 23 ROOM HEATING PEAK LOADS Project Title Date Washington Park - Pad 4 112/5/2006 Room Information Desi n Conditions Room Name zone 1 Time of Peak Jan 12 am Floor Area 1,403 Outdoor Dry Bulb Temperature 24 of Indoor Dry Bulb Temperature 70OF Conduction Area U -Value QT of Btu/hr 1403.0 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x X x x x x x 0.0347 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 46.0 = = = = = = c = = = = = c = = = = = c = 2,241 1,041.0 0.0655 46.0 31134 623.0 1.1900 46.0 34,103 _ Items shown with an asterisk (•) denote conduction through an interior surface to another room. Page Total: 39.4781 Infiltration: [ 1.00 1 x 1.080 x 1 403 x 16.00 x 0.00 / 60] x 46 Schedule Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 39,478 EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number: 05-088 Page: 18 of 23 FRow HEATING PEAK LOADS Conduction Area U -Value AT of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 13 097 Infiltration: F1.00 x 1.080 x 1 570 x 16.00 x 0.00 / 60] X 46 = chedule Air Sensible Area . Ceiling Height ACH &T Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 13,097 EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number: 05-088 Page:19 of 23 1,570.0 X X x x x X x x X x x X x x x x x x X x X X X x X X x x X x x x X x X x X x X 0.0347 X x x x X X x x X x x x x x x x x x X x x X X x x x x x X x x X X x X x x x X 46.0 = = = = = = = = = = = = = = = = c = — = = = = = = 2,508 699.0 0.0655 46.0 2,105 155.0 1.1900 46.0 8,485 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 13 097 Infiltration: F1.00 x 1.080 x 1 570 x 16.00 x 0.00 / 60] X 46 = chedule Air Sensible Area . Ceiling Height ACH &T Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 13,097 EnergyPro 3.1 By EnergySoft User Number: 3358 Job Number: 05-088 Page:19 of 23 ROOM COOLING PEAK LOADS - I Project Title Washington Park - Pad 4 Date 12/5/2006 ROOM INFORMATION DESIGN CONDITIONS 0.0347 Room Name zone 1 Time of Peak Jul 5 pm Floor Area 1,403 Outdoor Dry Bulb Temperature 109 `F Indoor Dry Bulb Temperature 74`l7 Outdoor Wet Bulb Temperature 78 9F Conduction Area X X X X X X X X X U -Value X X X X X X X X X 1,403.0 0.0347 213.0 0.0655 310.0 1.1900 299.0 0.0655 69.0 1.1900 529.0 0.0655 97.0 1.1900 147.0 1.1900 155.0 166 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain DETD 1 49.9 = 48.5 = 23.9 = 36.7 = 23.9 = 53.2 = 23.9 = 23.9 = Page Total Orientation Area X X X X X X X X X X SGF X X X X X X X X X X SC Weighting X X X X X X X X X X Page Factor = = = = = = (Southwest) 155.0 105 0.861 0.633 _(Northeast)_ 69.0 24 0.861 1.671 (Northwest) 155.0 166 0.861 0.456 (Northwest) 97.0 165 0.861 0.456 _(Northwest) 147.0 142 0.861 0.446 Total Btu/hr 2,431 676 8,833 718 1966 1,842 2,764 4,188 23 418 Btu/hr 8 874 2,382 _ 10,089 6_287 8,016 35,649 Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor Fights - 1.00 X 1,403 X 1.700 Watts/sgft X 3.413 Btuh[Watt X 1.000 = 8,138 Occu ants 1.00 X 1,403 x 230 Btuh/OCC. / 44 sgft/occ. X 1.00 = 7,334 ece tacle 01 x 1,403 X 2.000 Watts/sqft x 3.413 Btuh[Watt X 1.00 = 9,577 Process 01 X 1,403 X 5.000 Watts/sgft X 3.413 Btuh[Watt X 1.00 = 23,942 Infiltration: L 1.00 x 1.080 x 1 403 x 16.00 x 6] x 38 = Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 108,058 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x1403 X 190 Btuh/OCC. / 44 sgft/occ. Receptacle L.0.0 X _,4.03 X 0..000 Watts/sqft x 3.41.3 Btuh/Watt = 0 Process 1.00 X 1,403 X 0.000 Wafts/sgft x 3.413 Btuh/Watt = 00 Infiltration:[ oo X .784.0 x 1,_403 X 6.0.0 X 0...0. / 6] x 0.0.0.0.0.0 = BOJ Schedule Air Latent Area Ceiling Height ACH ow ROOM COOLING PEAK LOADS Project Title Washington Park - Pad 4 Date 12/5/2006 ROOM INFORMATION DESIGN CONDITIONS Room Name zone 2 Time of Peak Sep 4 pm Floor Area 1,570 Outdoor Dry Bulb Temperature 106 OF Indoor Dry Bulb Temperature 74`F Outdoor Wet Bulb Temperature 74 OF Conduction 30 Roof R.30.2x12.16 19 Wall (W.19.2x6.16) 19 Wall (W.19.2x6.16) Single Clear Default (NM) Area 1 1.570.01 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 0.0347 0.0655 DETD 1 42.4 = 31.0 = 51.5 = 21.0 = Page Total Weighting Orientation Area SGF SC Factor (Southwest) 155.0 X 180 x 0.861 X 0.545 X X X = X X X = X x X = X X X = x x x = X X X = X X x = X X X = X x X = Page Total Btu/hr 2,311 865 917 3,881 7,975 Btu/hr 13,076 13,076 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights — 1.0 13 X 1,570 X 1.000 Watts/sgft X 3.4Btuh/Watt X 1.000 = 5,357 Occu ants 1.00 x 1,570 X 230 Btuhlocc. / 70 Sgft/occ. X 1.00 = 5,159 eceptacle 01 X 1,570 X 2.000 Watts/sgft x 3.413 Btuh/Watt X 1.00 = 10,717 Process 01 X 1,570 x 5.000 Watts/sgft X 3.413 Btuh/Watt X 1.00 = 26,792 Infiltration: 1.00 x 1.080 x 1 570 x 16.00 x 0.00 / 60] x 38 = chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 69,075 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 1 570 X 190 Btuh/OCC. / 70 sgft/occ. = 4 261 Receptacle 1 00 X 1 570 X 0.000 Watts/Sgft X 3413 Btuh/Watt = 0 Process 1.00 x 1,570 X 0.000 Wafts/sgft X 3.413 Btuh/Watt = o0 Infiltration: [ 1 00 X X 57.0 x 6..0.0 X �0� / 60] X 0.0.0.0.0.0 = 0 Schedule Air Latent Area Ceiling Height ACH pw ROOM COOLING COIL LOADS I Project Title Washington Park - Pad 4 X X X X X X X X X Date 12/5/2006 ROOM INFORMATION DESIGN CONDITIONS = = = = = = Room Name zone 1 Time of Peak Jul 5 pm Floor Area 1,403 Outdoor Dry Bulb Temperature 109 OF Indoor Dry Bulb Temperature 74`F Outdoor Wet Bulb Temperature 78 `k Conduction �R-30 Roof R.30.2x12.16) -19 Wall W.19.2x6.16 in le Clear Default NM 19 Wall (W.19.2x6.16) in le Clear Default (NM) 19 Wall (W.19.2x6.16) ,Sin le Clear Default (NM) i5in le Clear Default NM Area X X X X X X X X X U -Value X X X X X X X X X DETD 1 = = = = = = 1,403.0 0.0347 49.9 213.0 0.0655 48.5 310.0 1.1900 23.9 299.0 0.0655 36.7 69.0 1.1900 23.9 529.0 0.0655 0.456 97.0 1.1900 23.9 147.0 1.1900 23.9 147.0 142 0.861 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Page Total Orientation Area x X x X X X X X X X SGF X X . X X X X X X X X SC Weighting X X X X X X x X X X Factor = = = = = = = = = = _(Southwest) 155.0 105 0.861 0.633 _(Northeast) 69.0 24 0.861 1.671 Northwest 155.0 166 0.861 0.456 _(Northwest) 97.0 165 0.861 0.456 _(Northwest) 147.0 142 0.861 0.446 - Page Total Btu/hr 2,431 676 8.833 718 1 966 1,842 2,764 4,188 23 418 Btu/hr 8,874 2,382 10,089 6,287 8 016 35,649 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr ights 1.00 X 1,403 X 1.700 Watts/sqft X 3.413 Btuh/Watt X 1.000 = 8,138 "Occupants 01 X 1,403 X 230 Btuh/OCC. / 41 sgft/occ. X 1.00 = 7,334 Receptacle 01 X 1,403 X 2.000 Watts/sgft x 3.413 Btuh/Watt X 1.00 = 9,577 Process X 1,403 x 5.000 •Watts/sqft X 3.413 Btuh/Watt X 1.00 = 23,942 Infiltration: 1.00 x 1.080 x 1 403 x 16.00 x 0.00 /601 x chedule Air Sensible Area Ceiling Height ACH LST Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 108,058 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 X 1 403 X 190 Btuh/OCC. / 44 sgft/occ. = 6 058 Receptacle x..0.0 X 03 X 0000 Watts/sgft X 3413 Btuh/Watt = 0 Process 1.00 X 1,403 X 0.000 Wafts/sqft X 3.413 Btuh/Watt = o Infiltration: [ 1...0.0 X 84.0 X 1.,403 X 6..0.0 X L O 1/ 6] X L OD.0.0.0 0 Schedule Air Latent Area Ceiling Height ACH n ROOM COOLING COIL LOADS Project Title Washington Park - Pad 4 DETD 1 Date 12/5/2006 ROOM INFORMATION DESIGN CONDITIONS 55.8 Room Name. zone 2 Time Of Peak Aug 4 pm Floor Area 1,570 Outdoor Dry Bulb Temperature 111 9F Indoor Dry Bulb Temperature 74`F Outdoor Wet Bulb Temperature 78 OF Conduction R-30 Roof (8.30.2x12.16) Area 427 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value I 1.19001 X X X X X X X' X X DETD 1 = = = = = = _ = = 55.0 38.0 55.8 25.0 Page Total Weighting Orientation Area SGF SC Factor. _(Southwest) .155.0 X 155 X 0.861 X 0.509 = X X X X X X = X X X = X X X X X X = X X X X X X X X X X X X = Page Total Btu/hr 3,001 1,063 993 4 610 9,667 Btu/hr 10,518 10,518 Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor Lights 1.0 X 1,570 X 1.000 Watts/sqft X 3.413 Btuh[Watt X 1.000 = 5,357 Occu ants 01 0 X 1,570 X 230 Btuh/OCC. / 70 sgft/occ. X 1.00 = 5,159 Occupants Receptacle r 1.00 X 1,570 X 2.000 Watts/sqft X 3.413 Btuh/Watt X 1.00 = 10,717 Process 1.0 X 1,570 X 5.000 Watts/sgft X 3.413 Btuh/Watt X 1.00 = 26,792 Infiltration: [ 1.00 X 1.080 X 1 570 X 16.00 X 0.00 / 60] X 38 = Schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FORROOM 68,209 Sched. Btu/hr Latent Gain Frac. Area Heat'Gain Occupants 1.00 x1.5701 X 190 Btuh/OCC. / 70 sgft/OCc. = 4 261 Receptacle 1..00 X _,57-0 X 0.0.00 Watts/sgft X 34x_3 Btuh/Watt = 0 Process 1.00 X� 1,570 X 0.000 Watts/sgft X 3.413 Btuh/Watt = o0 Infiltration: [ -00 E::4 8740 X X 5710 X t60X 00 s] X 00 Schedule Air Latent AreaCeiling Height ACH I pw