BMCH2019-022378-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type/Subtype: Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: c&t�t44094& DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT MECHANICAL/ BMCH2O19-0223 48751 SANTA URSULA 646130012 KNUDSEN / (2) HVAC CHANGE OUTS - 16SEER/80AFUE SPLIT SYSTEM $15,500.00 Applicant: IE INC. 32115 LA BAYA WESTLAKE VILLAGE, CA 91362 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 6/10/2019 Owner: ANN & MILES S. KNUDSEN 48751 SANT URSULA LA QUINTA, CA 92253 �. Contractor: JNN 10 2019 A#1 SERVICES HEATING & AIR CONDITIONING 78206 VARNER RD #D-189 CITY OF LA QUINTA PALM DESERT, CA 92211 DESIGN & DEVELOPI'viENT DEPARTMENT (760)565-2691 Llc. No.: 977333 LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C20, C36 License No.: 977333 Date: Ld 1051 Contractor:_ 7; .,��•z—.�� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: INSURANCE COMPANY OF THE WEST Policy Number: WPL5041680 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: (�L Applicaht: -�• WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above - mentioned property for inspection purposes. Date: fir" I D, I I q Signature (Applicant or Agent):; �� Date: 6/10/2019 Application Number: BMCH2019-0223 Property Address: 48751 SANTA URSULA APN: 646130012 Application Description: KNUDSEN / (2) HVAC CHANGE OUTS - 16SEER/80AFUE SPLIT SYSTEM Property Zoning: Application Valuation: $15,500.00 Applicant: IE INC. 32115 LA BAYA WESTLAKE VILLAGE, CA 91362 Owner: ANN & MILES S. KNUDSEN 48751 SANT URSULA LA QUINTA, CA 92253 Contractor: A#1 SERVICES HEATING & AIR CONDITIONING 78206 VARNER RD #D-189 PALM DESERT, CA 92211 (760)565-2691 Llc. No.: 977333 Detail: (2) 5-TON HVAC CHANGE OUTS - 16 SEER/80 AFUE SPLIT SYSTEM. CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. PER 2016 CALIFORNIA BUILDING CODES. CERTIFICATE OF COMPLIANCE Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC) Project Name: Ann Dotson Knudson I Date Prepared: CF1R-ALT-02-E (Page 1 of 3) 2019-06-07 A. General Information CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF1R-ALT-02 document for each dwelling unit. 01 Project Name Ann Dotson Knudson 02 Date Prepared 2019-06-10 03 Project Location 487515anta Ursula Street 04 Building Type Single family 05 CA City La Quinta 06 Dwelling Unit Name Ann Dotson Knudson Dwelling Unit Conditioned 07 Zip Code 92253 08 Floor Area (ft ) 3316 Number of Space 09 Climate Zone 15 10 Conditioning (SC) Systems in 2 this Dwelling Unit: B. Space Conditioning (SC) System Information 01 02 03 04 05 06 07 08 09 10 Is the SC Installing a SC System SC System CFA served system a refrigerant Installing new SC Installing Installing Installing Identification or Location or Area by this SC ducted containing system more than 40 entirely new entirely new Name Served System (ft) system? component? components? feet of ducts? duct system? SC system? Alteration Type Altered space System 1 Location 1 1658 Yes Yes Yes No No No conditioning system Altered space System 2 Location 2 1658 Yes Yes Yes No No No conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)1Diib) This section does not apply to this project. Registration Number: 419-A020058361A-000-000-0000000-0000 Registration Date/Time: 2019-06-10 13:22:08 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-06-10 13:22:08 Schema Version: rev 20180426 CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC) (Page 2 of 3) D. Altered Space Conditioning System (Sections 150.2(b)1E and F) O1 02 03 04 05 06 07 08 09 10 11 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length R-Value Central gas All new Central split All new This field or This field or System 1 furnace heating AFUE 0.8 AC cooling -SEER 16 Setback section is iot section is not components components applicable applicable Central gas All new Central split All new This field or This field or System 2 furnace heating AFUE 0.8 AC cooling SEER 16 Setback section is iot section is not components components applicable applicable Required Documentation: CF2R-MCH-01-E - Space Conditioning Systems - Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16) CF2R and CF3R-MCH-20-H - Duct Leakage Test required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced -Leakage rate compliance: <= 15 percent or <= 10 percent leakage to outside, or seal all accessible leaks. CF2R and CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2R and CF3R-MCH-23 Airflow Rate >=300 CFM per ton required when MCH-25 is required. Exceptions: Duct systems registered with HERS provider as previously sealed are exempt from MCH-20 Duct Leakage Testing requirements. Heating -only systems and Air Handler Furnace changes do not require verification of Air Flow MCH-23, or Refrigerant Charge MCH-25. -Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH-20 Duct Leakage Testing requirements. E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)1Diia and 150.2(b)1E, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C) This section does not apply to this project. Registration Number: 419-A020058361A-000-000-0000000-0000 Registration Date/Time: 2019-06-10 13:22:08 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-06-10 13:22:08 Schema Version: rev 20180426 CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC) (Page 3 of 3) Documentation Author's Declaration Statement 1.1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name Documentation Author Signature: Patty Hernandez Patty fternandek Company: Signature Date: I Permit E Raters 2019-06-10 Address: CEA/ HERS Certification Identification (if applicable): 31225 La Baya Drive City/State/Zip: Phone: Westlake Village CA 91362 818-735-7876 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Responsible Designer Signature: Cara Goldberg Cara.GoUberg, Company: Date Signed: A#1 Services Heating & Air Conditioning 2019-06-10 Address: License: 78026 Varner Road #D-189 977333 City/State/Zip: Phone: Palm Dessert CA 92211 (760) 342-3610 Digitally signed by CHEERSTM. This digital signature is provided in order tc secure the content of this registered document, and In no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 419-A020058361A-000-000-0000000-0000 Registration Date/Time: 2019-06-10 13:22:08 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-06-10 13:22:08 Schema Version: rev 20180426 ta Qaigra n/ /,,GSLKI'— PERMIT#GH11 PLAN LOCATION: Project Address: 48751 Santa Ursula Street Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: Replace (2) 5 ton / 60,000 BTU complete HVAC systems Applicant Name: Steven Schnierer Address: 31225 La Baya Drive Suite 213 City, ST, Zip: Westlake Village, CA 91362 Telephone: 818-735-7876 Email: swschnierer@roadrunner.com Valuation of Project $ 15,500 00 Contractor Name: A#1 Services Heating & A/C New SFD Construction: Address: 78206 Varner Road #D-189 Conditioned Space SF City, St, Zip Palm Desert, CA 92211 Garage SF Telephone: 760-565-2691 Patio/Porch SF Email: Fire Sprinklers SF State Lic: 977333 City Bus Lic: Arch/Eng Name: Construction Type: Occupancy: Address: Grading: City, St, Zip Telephone: Bedrooms: Stories: # Units: Email: State Lic: City Bus Lic: Property Owner's Name: Ann Dotson Address:48751 Santa Ursula Street City, ST, Zip La Quinta, CA 92253 Telephone: Email: New Commercial / Tenant Improvements: Total Building Construction Type: Occupancy: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 SF OFFICE USE ONLY # Submittal Req'd Rec'd Plan Sets Structural Calcs Truss Calcs Title 24 Calcs Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License Jack Lima From: swschnierer <swschnierer@road run ner.com> Sent: Monday, June 10, 2019 12:33 PM To: Jack Lima Subject: RE: Permit Request 1 of 3 - HVAC Replacement At 48751 Santa Ursula Street EXTERNAL: This message originated outside of the City of La Quinta. Please use proper judgement and caution when opening attachments, clicking links or responding to requests for information. The correct name is Ann D Knudson. Her name is listed first on the title, full name is Ann Dotson Knudson. -------- Original message -------- From: Jack Lima <jlima@laquintaca.gov> Date: 6/10/19 10:26 AM (GMT-08:00) To: Steven Schnierer <swschnierer@roadrunner.com> Subject: RE: Permit Request 1 of 3 - HVAC Replacement At 48751 Santa Ursula Street Good Morning Steven, Please verify the property owner name for this permit. The name provided on the application does not match the County. Respectfully, I j I ima2laaui ntaca. gov Jack Lima I Permit Technician City of La Quinta 78495 Calle Tampico - La Quinta, CA 92253 760.777.7195 From: Steven Schnierer <swschnierer@roadrunner.com> Sent: Monday, June 10, 2019 6:53 AM To: Aaron Hickson <ahickson@laquintaca.gov>; Armando Magallon <amagalion@laquintaca.gov>; Jack Lima <jlima@laquintaca.gov>; Stephanie Swanstrom <sswanstrom@laquintaca.gov> Subject: Permit Request 1 of 3 - HVAC Replacement At 48751 Santa Ursula Street EXTERNAL: This message originated outside of the City of La Quinta. Please use proper judgement and caution when opening attachments, clicking links or responding to requests for information. Steven Schnierer I Permit E Raters 31225 La Baya Drive Suite 213 Westlake Village, CA 91362 Office: (818) 735-7876 Fax: (818) 735-3575 Cell: (951) 334-9978 Email: swschnierer@roadrunner.com Website: www.ipermiteraters.com 2 DocuSign Envelope to: 42A70370-5EBA-47BA-B1 BE-002AEEE93859 C �- � .-i:I1-rrTrr�a License Number 977333 78206 Varner Rd, Ste D-189 • Palm Desert, CA 92211 (760) 565-2691 • info@al svc.com PROPOSAL AND HOME PERFORMANCE CONTRACT This home improvement contract is entered into by and between A#1 Service Heroes Conditioning ("contractor") and Ann Dotson dotsoninteriordesign@gmail.com (Owner), whose residence address is 48751 SANTA URSULA, LA QUINTA, cA 92253 and project address is SAME AS ABOVE 1. Description ofwork, description of the project and description or the significant materials to be used and equipment to be installed: See the Plans Attached 2. Date of proposal: 6/6/2019 API Service Heroes proposes to furnish you, the client with all materials, labor, and supplies as detailed in the plans approved by you which are attached to this contract 3. Acceptance: This proposal is null and void if you have not accepted it within seven (7) days following the date of proposal specified above, unless A01 Service Heroes extends the acceptance period in writing. If you accept the proposal and sign this contract including the plans it is binding on you, subject to your right to cancel in paragraph 19 below. 12. Applicable Law: This contract is governed by the laws of the stale of California, 13. Cost of Dispute: If any dispute between you and AiiI Service Heroes results in arbitration or litigation„ the prevailing party (as determined by the arbitrator or court will be entitled to recover its - reasonable attorney fees and costs 14. Commercial General Liability Insurance: Aill Service Heroes carrier's commercial general liability insurance written by Praetorian Insurance Company you may call 760-360-4700 to check the contractor's insurance coverage 15. Workers Compensation Insurance: Ad1 Service Heroes carries workers compensation insurance for all employees- 4. Contract Price: S S15.500 16. List of Documents Incorporated into the Contract: (1) Plans, The plans will be completed in a professional and workmanlike (2) Three -Day Right to Canccl, (3) Notice of Cancellation, and (4) manner for the contract price listed above Limited Warranty (5) Mechanics ]can Warning 5. Down payment: S 55, 500 THE DOWN PAYMENT MAY NOT EXCEED S1,000.00 OR 10% OF THE CONTRACT PRICE, WHICHEVER IS LESS. 6. Payments: Payment will be made in full less any down payment by cash, check, or credit card to Atil Service Heroes' installers or other A41 Service Heroes representative at the completion of the install. Install is complete when the equipment and materials outlined in the contract arc installed and operating. Balance Due: S $10,000 (BEN3I) 7. Approximate Start Date: 6/6/2019 Ai,'] Service Heroes plans to start work on the approximate date above Work is considered to have begun when materials for your plans have been ordered 8. Approximate Completion Date: 6/6/2019 The work should be substantially completed by the approximate date above unless the work has been delayed due to circumstances beyond the control of Alll Service Heroes, 9. Permits and Tests: AIli Service Heroes will pull all of the required building permits required for this job, and will have a 3rd party perform all of the required HERS testing as required by Title 24. 10. Note about Extra Work and Change Orders: Extra work and change orders become part of the contract once the order is prepared in writing and signed by the parties The order must describe the scope of the extra work or change, the cost to be added or subtracted from the contract, and the effect the order will have on the schedule of progress ofpayments, ifany Failure to comply with the requirements of this paragraph does not preclude the recovery of compensation for work performed based upon legal and equitable remedies designed to prevent unjust enrichment 11. Default by ANI Service Heroes: If you believe that A41 Service Heroes has breached this contract, you must notify Alil Service Heroes in writing at the above address, ATTN: General Manager, describe the alleged breach, and give A01 Service Heroes at least thirty (30) days to cure the alleged breach 17. Entire Agreement: This contract, the plans, the warranty (which appears on a separate page if applicable), and any other document attached or otherwise made part of this contract constitute the entire agreement between Aill Service Heroes and you, the client relating to the plans. No other agreements, oral or written, regarding the work to be performed or the price to be paid under this contract exists between you and A8I Service Heroes However AN I Service Heroes will deliver to you any manufacturer warranties that come with any materials you purchase Manufacturer warranties arc the responsibility of the manufacturer and Aiil Service Heroes is not liable for them 18. Information about the California Contractors State License Board (CSLB): CSLB is the state consumer protection agency that licenses and regulates construction contractors • Contact CSLB for information about the licensed contractor you are considering, including information about disclosable complaints, disciplinary actions and civil judgments that arc reported to CSLB, • Use only licensed contractors • If you file a complaint against a licensed contractor within the legal deadline (usually four years), CSLB has the authority to investigate the complaint • If you use an unlicensed contractor, CSLB may not be able to help you resolve your complaint Your only remedy may be in civil court, and you may be liable for damages arising out of any injuries to the unlicensed contractor or the unlicensed contractors employees. For more information: Visit CSLB's web site at www.cslb,cagov Call CSLB at 800-321-CSL13 (2752) _"WriW SCLB at P.O Box 26000, Sacramento, CA 95826 Ww.. 19. Three Day Right to Cancel: The law requires that the contractor give you a notice explaining your right to cancel, Initial the checkbox if the contractor has given you a Notice of the Threc-Day Right to Cancel, 20. Notice to Client: You are entitled to a completely filled in copy of this contract, signed by both parties, before any work may be started. �Docual�•re[y Signature ofClient&A(uLV', Date:6/6/2019 �--+s9a��wvawm Print name of Client: Ann Dotson Signature ofA#1 Service Heroes's representative pt]Lr.us Print name ofA#1 Service Heroes'srepresentative Greg GrargLr Comfort Advisors Registration #: 115279 SP Date 6/6/2019 Do uSign Envelope ID: 42A70370-5EBA-478A-B1 BE-002AEEE93859 C Mechanics' Lien Warning Anyone who helps improve your property, but who is not paid, may record what is called a mechanics' lien on your property- A mechanics' lien is a claim, like a mortgage or home equity loan, made against your property and recorded with the county recorder. Even if you pay your contractor in full, unpaid subcontractors, suppliers, and laborers who helped to improve your property may record mechanics' liens and sue you in court to foreclose the lien. If a court finds the lien is valid, you could be forced to pay twice or have a court officer sell your home to pay the lien. Liens can also affect your credit. To preserve their right to record a lien, each subcontractor and material supplier must provide you with a document called a '20-Day Preliminary Notice'. This notice is not a lien. The purpose of the notice is to let you know that the person who 'sends you the notice has the right to record a lien on your property if he or she is not paid. BE CAREFUL. The Preliminary Notice can be sent up to 20 days after the subcontractor starts work or the supplier provides material. This can be a big problem if you pay your contractor before you have received the Preliminary Notices You will not get Preliminary Notices from your prime con- tractor or from laborers who work on your project. The law assumes that you already know they are improving your property. PROTECT YOURSELF FROM LIENS. You can protect yourself from liens by getting a list from your contractor of all the subcontractors and material suppliers that work on your project. Find out from your contractor when these subcontractors started work and when these suppliers delivered goods or materials. Then wait 20 days, paying attention to the Preliminary Notices you receive, PAY WITH JOINT CHECKS. One way to protect yourself is to pay with a joint check. When your contractor tells you it is time to pay for the work of a subcontractor or supplier who has provided you with a Preliminary Notice, write a joint check payable to both the contractor and the subcontractor or material supplier. For other ways to prevent liens, visit CSLB's Web site at www-csib.ca.gov or call CSLB at 800-321-CSLB (2752)_ REMEMBER, IF YOU DO NOTHING, YOU RISK HAVINGA LIEN PLACED ON YOUR HOME. This can mean thatyou may have to pay twice, or face the forced sale of your home to pay what you owe Notice required by California Business and Professions Code § 7159(c)(4): When payment is made for any por- tion of the work performed, Contractor shall prior to any further payment being made, furnish to Owner a full and unconditional release from any claim or mechanics' lien pursuant to § 3114 of the Civil Code for that portion of the work for which payment has been made.