Loading...
BPAT2019-003278-495 CALLE TAM PICO LA QUINTA, CALIFORNIA 92253 Permit Type/Subtype: Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: CS PATIO COVERS 82857 WHEATLEY COURT INDIO, CA 92201 c&tit4.GfvQu;,a DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT PATIO COVER/CITY STANDARD/PRE-ENGINEERED - OPEN BPAT2019-0032 44630 N N HARLAND DR 604231015 BEHRENS / 354SF TRELLIS DURALUM PATIO COVER AT FRONT YARD VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Owner: Behrens Garrett R & Natascha B 44630 NORTH HARLAND DR LA QUINTA, CA 92253 $1,675.00 Contractor: CS PATIO COVERS JUN 2 g 2019 82857 WHEATLEY COURT INDIO, CA 92201 CITY OF LA QUINTA (760)625-4225 DESIGN & DEVELOPMENT DEPARTMENT Llc. No.: 1004320 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: D03 License No.: 1004320 % Date: I— I'L-A 1I"X Contractor OWNER -BUILDER DECLAFMT10N I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) 1 am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Date: 6/28/2019 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: MP Policy Number: _ Z IV1 certify that In the performance of the work for which this permit is issued, I shal at mp ❑ person In any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Cod , I shall forthwith comply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPEN ON COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upo the above-mentlanetUd� property for inspection purpryses. Date: L4 Signature (Applicant or Agent Date: 6/28/2019 Application Number: BPAT2019-0032 Owner: Property Address: 44630 N N HARLAND DR Behrens Garrett R & Natascha B APN: 604231015 44630 NORTH HARLAND DR Application Description: BEHRENS / 354SF TRELLIS DURALUM PATIO COVER AT FRONT YARD LA QUINTA, CA 92253 Property Zoning: Application Valuation: $1,675.00 Applicant: Contractor: CS PATIO COVERS CS PATIO COVERS 82857 WHEATLEY COURT 82857 WHEATLEY COURT INDIO, CA 92201 INDIO, CA 92201 ' (760)625-4225 r i = Llc. No.: 1004320 Detail: BEHRENS / 354SF TRELLIS PATIO COVER AT FRONT YARD; [DURALUM] THIS PERMIT DOES NOT INCLUDE ELECTRICAL INSTALLATIONS. 2016 CALIFORNIA BUILDING CODES. DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT CITY AMOUNT PATIO COVER, STD, OPEN 101-0000-42404 0 $107.27 DESCRIPTION ACCOUNT CITY AMOUNT PATIO COVER, STD, OPEN PC 101-0000-42600 0 $105.66 Total Paid for PATIO COVER / COVERED PORCH / LATTICE: $212.93 DESCRIPTION ACCOUNT QTY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT CITY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $0.50 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $0.50 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 PERMIT # PLAN LQCATION : Project Address: D f Project Description: APN #: O (,1 a-tI� LPL �� ir1�j C V� Applicant Name: Cl�l �feS C.�k / .q o +�b, VQL ea Address: �{ �--�l. t C7 oS City, ST, Zip: t zzo 1 l_G✓VCY'-� f7C Telephone: 7&0 Cp-2-5 ` 2-2-9- Email: Valuation of Project $ Contractor Name: GS /u�7rU (OlVflS New SFD Construction: Address: (�ZYS Cl Conditioned Space SF City, St, Zip Garage SF Telephone: 76, 0 ZS �� Patio/Porch SF Email: Fire Sprinklers SF State LigleVq�Zv City Bus Lic: Architect/Engineer Name: Construction Occupancy: Address: Grading: City, St, Zip Telephone: i Bedrooms: Stories: # Units: Email: State Lic: City Bus Lic: r ,� l� 1_�21,� � Property Owner's Name: do inNew �-V Commercial / Tenant Improvements: Address: '/ V&30 r4r Total Building SF City, ST, ZipS Construction Type: Occupancy: Telephone: 70 0 53 4 510 Email: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 OFFICE USE ONLY # Submittal i Plan Sets Structural Calcs Truss Calcs Required Received I Title 24 Calcs Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License ,It Vic{ r�-oi C=�grc�e i 13FA-r2ON -003Z CITY OF D QUlffTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE�710�11BY 346q sF potAl-VA4 L An FA -no ",/" C> r-40r YAR D ana.wa,� I<.vP. (�n-,n-A- YUrd ) C): 1' lib AV-eaj19C- , 7k 6Z S Zt2 Z. C-4 . 0 � C) WigP T/Ayjr CS PATIO COVERS 82857 Wheatley Ct Indio, Ca 92201 Phone: (760) 625-4225 Email: candspatiocovers@hotmaii.com Web: www.cspatiocovers.com Description 12x30 Weatherwood Open lattice Structure Natascha Behrens 44630 north harland dr, La quinta (760) 534-8017 Payment Terms Invoice # Date Business / Tax # Attached to wood fascia board Reinforce eave with A34 framing angles ' Posts arnchord to concrete footings. { 3x3 posts with 2x6 filled side plates c^� 3x8 header cros m l� v � Lattice tube size: 2x or 2x2 Spacing between tice: 2" standard Color: End cut: Lifetime warranty AVAILABLE UPGRADES 4" Led lighhting $135.00 each Lifetime warranty included for lights and electeical work. Fan beam and electrical $220.00 each (Fan not included) City Permit Cost And Processing fee 3 Posts Are Required With No Steel Reinforcements Per Engineering Specs From Duralum Manufacturer Christian Angulo 760.625.4225 Subtotal Total Pagel of 4 Due upon receipt 000910 05/27/2019 Lic # 1004320 Total $3,960.00 $0.00 $485.00 $0.00 $4,445.00 $4,445.00 owAE0. AcrAoiLmATIvA CONTRACTOR AGREEMENT THIS AGRE ME i made and entered this 24 day of ` 416 i.J• r b nd between hereinafter called the Contractor, and hereinafter cal ed he Owner. THIS AGREEMENT shall become effective on the date of execution hereof, and shall remain in force until terminated by either party. In the event of any termination of this Agreement, all work -in -progress will be completed in accordance with the terms and conditions set forth herein. WITNESSETH, that the Contractor and the Owner for the consideration named herein agree as follows: ARTICLE 1. SCOPE OF THE WORK The Contractor shall furnish all the materials and perform all of the work shown on the drawings and/or described in the Estimate, unless specified otherwise. ARTICLE 2. TIME OF COMPLETION 7/� The vxork to be performed under this Contract shall be cornrnenced on or before 20_a and shall be substantially completed on or before "` ; 20 iL ; . Time is of the es5er1ce. ARTICLE 3. THE CONTRACT PRICE The Owner shall pay the Contractor for the material and labor to be performed as shown on Contract. Therefore, 10% of the total balance shall be liquidated upon Contract Approval. Finally, a 50% of the total balance will be immediately due on special order material and rushed jobs. ARTICLE 4. DETAILED PAYMENT BREAKDOWN In reference to the liquidation of TOTAL CONTRACT PRICE: Owner and Contractor hereby agree to the following Payments being processed by this manner and will follow t is paymen schedule set forth: ARTICLE 5. OWNER CANCELLATION In the event Owner wishes to cancel this transaction the following will occur: Contractor and Owner acknowledge the existence of a three day period to cancel and may exercise this right based upon Contract Agreement dated above. The Owner is fully responsible that he/or she is liable of paying 50% from the total Restocking Fees if cancels after the three day period time frame. 50% deposit on special order materials or Rushed jobs, 10% deposit upon agreement However, if the Owner cancels before the three day period time frame, there will be no monetary penalty for doing so. Contractor: Initials:C4 Owner. 0 Initials. ARTICLE 6. GENERAL PROVISION 1. All work shall be completed in a workmanship like manner and in compliance with all building codes and other applicable laws. 2. Contractor may at its discretion engage subcontractors to perform work here -under, provided Contractor shall fully pay said subcontractor and in all instances remain responsible for the proper completion of this Contract. 3. All modifications pertaining to the project shall be processed in writing and must be mutually signed by both Owner and Contractor. 4. Contractor warrants it is adequately insured for injury to its employees and others incurring loss or injury as a result of the acts of Contractor or its employees and subcontractors. 5. Contractor agrees and is responsible to remove all debris and leave the premises in broom clean condition. Page 2 of 4 6. In the event Owner shall fail to pay any periodic or installment payment due here -under, Contractor may cease work without breach pending payment or resolution of any dispute. 7. Upon completion of this Contract, Owner shall fully pay remaining balances immediately. In the event Owner breaches this Agreement, Contractor may exercise its right to seek legal counsel and/or seek legal remedy by reporting this fraudulent act to a Collection Agency or file a Mechanics Lien against subject property where the project took place if not done so within 20 days of completing project. 8. All disputes here -under shall be resolved by binding arbitration in accordance with the rules of the American Arbitration Association. 9. Contractor shall not be liable for any delay due to circumstances beyond its control such as caused by natural disasters, examples include ❑ods, eartklqukes and other geologic processes. Strikes, casualty or general unavailability of ate i 1 10. Contractor warrants all work for a perio of ontfs following completion. ARTICLE 7. OTHER TERMS a;�4e n• �1-P11 ; Signed this day of i' ' , 20-a- I' Home Our Contra DURALUM PRODUCT LIFETIME -WARRANTY Full Warranty- Duralum warrants that its Patio Covers, Room Enclosures, Weather products, Window Awnings, Screen Rooms, when installed with proper engineering and permitting in accordance with local U.S building codes and in accordance with installation instructions, are free form defects in material & workmanship & the finish on the products will not chip, peel, flake, or blister under conditions of ordinary wear for the lifetime of the product, except as provided below under "Exclusions & Limitations." What C&S Patio Covers Will Do- C&S Patio Covers shall have 45 days to repair or to address any defects covered under this Limited Warranty. Exclusions & Limitations- Neither of these warranties covers any chipping, peelings, flaking or blistering of the products as the results of damage of any kind resulting form faulty or improper installation, accidental or intentional damage, setting structural shrinking or other distortion of the property structure, popping due to expansion or contraction, acts of God, harmful chemicals (including harmful cleaning compounds), fumes or vapors, surface deterioration due to air pollution, "normal weathering', condensation, mildew accumulation, impact of foreign objects, rust or corrosion of any of any components or the products, or the failure of the owner to provide reasonable maintenance of the product including periodic removal of dirt and pollution residue as necessary. Neither of these warranties covers fading of any paired finish due to normal weathering, or any rust of any components of the products, including but no limited to, screws and other fasteners, and any steel components. Also, no warranty applies if the product has been painted or the surface has been altered. "Normal weathering' is defined as the Page 3 of 4 damage affects of sunlight & the extremes of weather and atmosphere that may cause any colored surface to face or become soiled or stained. If air occurs up to 130 miles per hour warranty covers. Christian Angulo Page 4 of 4 Natascha Behrens PATIO OVER SYSTEM AS MFG.' BY: DURALUM PRODUCTS, INC. POINT OF CONTACTS INFORMATION REQUESTS SHALL BE DIRECTED AS FOLLOW. CONTRACTORS: PLEASE CONTACT DURALUM BUILDING DEPARTMENTS : PLEASE CONITAC145TR ENGINEERING HOME OWNERS: PLEASE REOUESTANY INFORMATION THROUGH YOUR CONTRACTOR 26030 ACERO SUFTE 2D0 PHONE: (949) 3D5.1150 MISSION VIEJO, CA 92691 FAX 1949) 30S.1420 STRUCTURAL ENGINEER OF RECORD: DUSTIN K ROSEPINIC SE 5BB5 POINT OF CONTACT: MARIE-DOMINIQUE SETA SE 5967 DESIGN PARAMETERS SN IF ATTACHED AND FREESTANDING COVERS SHOWN IN THIS REPORT COMPLIES WITH THE FOLLOWING CODES • 2DI3/2D15/2011 INTERNATIONAL BUILDING AND RESIDENTIAL CODES, • 2DI3/2016 CAUFOHNIA BUILDING AND RESIDENTIAL CODES, • ASMJSEI7.10 and 7.16 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHERSTRUCTURES, - 2D35 ALUTAINUM DES: GN MAN UAL N -~ W..`..,..,�, ♦% NTFTYSUBMIEFINMEDRAWINGSFORTHISPROJECFTOVENPYLIVELOADSWITHTHELOCALAUTHORITYRAVINGJURISDICTION L IN RESIDENTIAL APPLICATIONS, ROOF LIVE LOAD CAN GENERALLY BETAKEN AS 10 PSF PER IRC / CRC APPENDIX H, SECTION AH1D510R IBC/ CBC APPENDIX L SEL11ON 1051 2 IN COMMERCUALAPPLICATIONS, ROOF LIVE LOAD CAN GENERALLY BETAKEN AS 20 PSF PER IBC/ CBC CHAPTER 16 WIND SPEED DESIGN pAlIAMma- L THE PRE E TANDHNEAND ATTACHED COVERS NOTED HERON ARE DESIGNED AS'OPEN STRUCTURLS,' IN ACCORDANCE WITH ASCFJaE17. 1 FREESTANDING COVERS SHALL NOT BE ENCLOSED WITH ANY TYPE OF SOLID OR MESH MATERIAL, UNLLaT SPEOFCALLY• L 95NM OVA REGISTERED PROFESSIONAL ENGINEER 3. COVERS SHALL NOT BE INSTALLED IN AREAS NEAR HILLS, RIDGES AND BCARPMEN75 AS DEFINED IN ASCE/SO 7, SE=N 2" UNLESS 3 7E SPEC HE EHGI NEWNG 6 PROVIDED VALIDATING THE WIND LOAD USED. 4. THE BASIC VVIND SPEEDS CONSIDVp_-D IN THS R:POFT ARE 110, 32D, 33D MPH, EXPOSURES BAND C (BASED ONTP.E20121BC 2015/2➢18 IBCARC. AND 2DJ3/2DL6 CBC/CRC). S. FOR USE WITH THE 2012IRCAN02G13CRC,DMDETHE ABOVE MFNTIONNEDWIND SPEEDS BYSQRT(D.6), CBC / IBC WIND SPEED 11D MPH 120 MPH 1 130 MPH EQUIVALENT CRCRRC WIND SPEED BS MPH" B3 MPH 1G1 MPH EYAMPLE IF 2012 IRC OR 2013 CRC WIND SPEED 6 95 MPH, THE PATIO COVER CONSTRUCTION SHALL BE BASED ON 95 MPH/ SQRTI(L6)=11D MPK SNOW 1=5 DMIGN PA,tAmETEp3• IT IS THE RESPONSIBILITY OF THE ENTITY SUBMITTING THE DRAWINGS FOR THIS PROJECTTO VERIFY SNOW LOADS WITH THE LOCAL AUTHORITY HAVING JURISDICTION L GROUND SNOW LOADS Pg ARE LISTED IN THE TABLES OF THISREPORT. FLAT ROOF SNOW LOADS Pf WERE USED 70 GENERATE THOSE TABLES, PER ASCE EQUATION 73.1, U51NG Cr-LD AND CI=12 THE FOLLOWING TABLECJH DM INE _ p y; 2 WHEN THE LOCAL AW HAS SPECIFIED A FIAT ROOF SNOW LOAD TO BE USED AT THE ATE, THE CONTRACTOR SHALL USE THE TABLE ABOVE TO FIND THE EQUIVALENT GROUND SNOW LOAD TO BE USED WHEN USING THLSREPDRT. WHEN NO ROOF SNOW LOAD IS SPECIFIED BY LOCAL ARI, USE THE CODE SPECIFIC GROUND SNOW LOAD VALUES ATTHE SITE WHEN USING THE WORT, 3. WHERE SNOW LOADS OCCUR, THE CONTRACTOR FOR THE PROJECT SHALL VERIFY WITH THE LOCAL AUTHORITY HAVING JURI.SDICnON WHERE DESIGN FOR SNOW DRIFTING / ORSUDING G REQUIRED PER ASCE 7-10 AND 7-16, SECTION 7.7 AND 7.8. 4. DESIGN FOR SNOW DRIFT AND SLIDING HAVE BEEN CONSIDERED IN THIS SET OF DRAWINGS FOR ATTACHED COVERS. WHERE SNDW LOADS DRIFTING AND / OR SUDING 0'['tUR, REDUCTION FACTORS PER SHEET 521 OR L21 SHALL DE APPLIED TDTHE STRUCTURE ' S. DESIGNFDRSNOWDRIFTANDSUDINGFORDETACHEDCOVERS15BEYONDTHESCOPEOFTHISREPORTANDREQUIRESSTTESPECIFICENGINEERING. PW FR-IuM FARAM1LILK5 TO 0E USED WITH InP410 D505: APPLIED PRESSURE LOADING. TO BE USED IN IAPMC7 am WIND (MPI•Q ROOF WE/GROUHD SNOW LOAD AS REFERENCED IN'MLSREPDRT 10 20 1 25, 3D 4p 5Q 0313EIEI 310 1.2DC 15 25 25 3D 40 45 SIB 2D 25 25 30 40 cs USE LESSER SPAN FROM IAPMD-0505 FROM ALL LOAD TIDES (LNE, WIND, SNOW) FOR APPLIED PRESSURE LOADING FROM TABLE ABOVE 5EISNIIC LOAD DESIGN PARAMETERS: SEISMIC DESIGN BASE SHEAR:17 POUNDS PER LINEAR FOOT PER WIDTH OF COVER, CONSIDERING THE FOLLOWING DESIGN PARAMETERS: L SITE CLASS: D 2 SEISMIC DESIGN CATEGDRI': E 3. MAPPEDSPECTRALRE5PDNSECOEFFICIENTS: Ss =15D,S3 -0.6,Sds = III, Sd1 =O5D A. RESPONSE MODI R DATION FACTOR, R=125 , S, RISK CATEGORY II G. THE PATIO COVER MU,'TURES DETAREO IN THIS SET DF PLANS ARE IN COMPLIANCE WITH ASCE 7.10 SECTION 126.13. AS A RESULT, THE SET OF PLANS CAN BE USED AT ANY SITE WITH Ss > ]S0, WNSIDERING S<= L5D WHEN DESIGNED PER 2MZnD15 IBC,RNC AND 2DI3/2D16 CBC/CgC 7. THE PATIO COVER G7RUCTU RES DETAILED M TNIS SET OF PLANS ABLE IN COMPLIANCE WITH ASCE 7-16 SECTION IM•y3, ,t A RESULT, THIS SET OF PUNS CAN BE USED AT ANY SITE WITH LDdds4A2B, CONSIDERING Sds = %A FOR SFFES WITH S&s *Z, USE Sd , FOR SITES WITH 56PL428, IT ISACCPTABLE TO REDUCE 1HE MFEMIC LOADS USING 0.7 Sds INSTEAD DF $6, OTHER DSIGN PARAMETERS- L DESIGN LOADS COMBINATIONS ARE IN ACCORDANCE WITH IBC AND CBC SECTION 16053-L L ALL APPLICABLE REDUCTION FACTORS DETAILED IN THIS REPORT ARE CUMULATIVE 3. SOLID AND LATTICE ALUMINUM COVERS ARE CLASS A ROOF A55EMBLY IN ACCORDANCE WITH SECTION CBC 1505-7, EXCEPTION L L MINIMUM ROOF SLOPE FOR SOLID ROOF PANELS WITH DECX: SEE DETAIL I8/531 2 MINI AUMROOFSLOPE FOR SOLID ROOF PANELS WITH DURAPANEI:SEE DETAIL IA/92 3. MAYIMJM R DOF SLOPE FOR ALLSTR LICTIR S IS 3 DEGREES A. THE'LENuTH OF STRUC I-mrSHALLSETAX5 AS THE mNFINUM61STAKU MERSUREDALONE THE E"a BUILDING WALL FROM ONE END OF PATIO COVER SUFPORT BEAM TO THE OTHER: INCLUDING ANY BEAM SPLICES. THE SFP.UCTURE LENGTH SHALL SE DETERMINED WAY REGARDUM OF ROOF COrRING TYPE.INCLUIDINGCOMBINATION ROOFS WITH 07M 7RELW AND DECK ROOF USED ONTHE SAME CONTINUOUS PATIO COVFRSTRUCTURE. HOWEVEA, OPEN LATTIMPORTIOYS DFTYFSTRUCTURESHALLNOT IECOVERI.o BY ROOF DEOL PER j"D M S. CkLICU ATTOYS FOR MAXIMUM SPANS Yr7:EN ATIACHI NG TV AN MSFI NG ROOF OVERHANG AS SHOWN ON TABLE 1 ON 561 AND/OR I6.%ARE ASSUMING THAT THE DLISFTNG WODD RAFTERS OR TRUSSES ARE DDUGW 1111-LARCH NDL THIS TABLE CAN ALM BE USED FOR [TITTER WOOD SPECIES WITH Fb290D psi AND Fv i 180 psL GENERAL NOTES DRAWINGIJpTES ; 1 THE ➢RAV5IN DDIRECTTHEWO +l,7HSSHIOLVM R8'RE3EFTITH# FTNi571EDSTRUCTLRE; UNLs55 07i4RPPlSE HOTEO, RHD DO NDT INDICATE THE METHOD OF CON511TUL'.TpP1THE CDNTRACTpRSHALL SUtiERVLSE AND DIRECT THE WORK AND STALL BE $OLESY RIVDNS W FOR ALL CDKM UMDN Z TdEAPPeOVM SCT DF DPUAMNMAND3pla;r no!D SHALL W KEpTp, plE )DB in AYD ��TMIQUI3 SEOUENCSAND PROCEDURM SHALL BENODEVIA7XIN}�MTNT APPROVED PLANSAND SPECInCATIDNSWFTODUTANAFFRDVEDDCHANGE ORDER. AlT<HpRZ=➢REPRESENTATIV}3OFTHEBUILhfNGAND54FE'FYDEPARTMEM.THERE MATEEBEI SP9:DFIG{TpffSS L ALTERNATE E iUM1NUMAUDYSMAYBE SUBSiTR1TEDFOR THOSE SHDWN,PgDVIDEDiHEYARERE MEGLSREDWITH 7HEALUTA1NUMkZOCIA710NAN0HAVE EQUAL 0RGREA7ERYEILDANDULTIMATE CATS 2 M—ETES.I;?UIWEAMWIMUM23DAY CDMPRMFVEMENGTHDF2SDOPOIINDSPEILSQUARE INCH. 3. EMBEDDEOSTEELh!EMBERSSHALLgEy�7,plppEDGAiVRHiTED,ANPCOHFD 4. BOLTS:PLMT0ASLb6PUEB,ROIIFORMED STEEL MEMBERS 5HALL CONFORM TOA93-SS(STRUCrURALSTEEL)GRADE 50G60. . 1AMUMBOLTSSRALLBE2024-T4ISTEEL RMTSSHAU.BEASTMA-307. ALL BOLwkA4HAVESiANDARD.ozRATED WAS HERS. S. SCAEINS: ALL 5CREWSA,AESE F DRILLING (SDSI ORSNEF7 METAL SCR V4,VS) IN CONMRMANCEW rL FASTIFN ICC-FS ESR1976, ICE•FSR 3006, ORAPPROVED EQUAL FJVERS To WOOD: WOOD AND IAGSCAEVt; ARE RERINRED TO REINSTALLF9 IN ACCORDANCE V`fM"gE2r RAT DNALDESIGH SPECIFICATIONS, INCLUDING PRE-DRIWNG OF HOLES. 7. POST INSTALLED ANCHDRS-PDST-]NSTALLEDANCHORS LISED SHALL OEM"'P;ON STRDNC TIE STRONG BELT 7, STAINLESSSTEEL JICC-ESR 3037) OR EQUAL B. ALIMh1PDNEhTS_FAANUPP4TURpORSUPPLIED BYDURALUMAND DESCRWIDNTHE DUCIOAENRARE iNTEgD1qD}uEABLE,PRDVIDEDTHFYpRESEIFCTEDAPPRDPRIATELY7D5UPPDRTTHELOADRJG THEY ARE SUBIECT 70. LF B. ROOF THE INSULATED ED PAN S (AHD ®VER LDM*pNEN!S IN THIS REPORT CAN BE CALCULATED FROM SECTION PR OPEATUMTHE SOLID COVERS VARY IN WEIGHT FROM ABOUT I PSF TO ABOUT 3 PSF, E PA 10, ROOF INSULATED FME15 (WHERE QCDASS'ASff 532. SDLARPAHELINSikIAnoH: JURISDIAT10N OF SDI.AR PnNElS ON TOP DFTHLS STAUCNRE HAS SPEUFIC REQUTAEMENR PLEASE CONTACT DURALUM PRIOR TD ORDERING THE PARTS AND SUB MRTNG DRg1Yl NGS 77 LOCAL ALJTHDRHY HAV NG JLOIGLICTIpsI FOOTINGS: w L ALL NEW CDNCRETT ICALSOFBEARINSSHALL BEAR 1,500P POUNDNl-WRS RSQUREFOOD501lOBCE1CTIFlEDFlU_ CIi9l, � A 2 DESIGN VERTICAL SOIL BEARING PRESSUREB150D POUNDS PER SQUARE FOOT. VV. fI�IO� 3. DESIGN LATEMBOIL BEARING PRESSURE G 20D POUNDS PER SQUARE FOOT PER FC>"JT OFFOOTINGD V A. THE BOTTOM OP FOOTINGS SHALL EXTEND BELOW THE FROST DEPTH. CONTRACTORTOVMFYFROSTD (EQUALS WffHAIJfHkoWbOFOR SLABON@KALIFUSEDASAFpUNDAnDN,vmM: W WRRCE IRC%.RCAPFfFI~ AH1D52, AND IBUIRCAPPENDIX LSECTION 11M2,INA WRHAFRDS 70ANExlSTFNG SAPRMIDEDTHEFD=WING: * ER'BE53pFJiDALUSEMAV EaxL]IBEDL THE SLABDNGRADEISATLEASF31/2INCHESTHICK , `v2. THE MAXIA'IIM DFZ&DLRFE j SNOW LOAD ATLACH COLUMN IS750 POUNDS, 3. THE SLAB ON GRADE SHALL BE A MINIMUM OF 10'•D' WIPE BY THE MAXIMUM COLUMN SPACINGMEASU 0 00NTROLIWANSIDN JOINT DEEPERTTmJf2'.�OR 4. THERE SHALL OR AV MINIMUM 087ANCE EFIYVEEN RlJT' ANCHOR BDLTAND ASLAB EISGE CRACK WIDEF 1TLAN 1/32- OR CONTROL/EXPANSION JOINT DEEPERTHAN 11Z- OSTGRFDAPATTDCOVETSSi1PPpRFEOON{M1QE-ES:ABpNGRAOF151ItA=;LDAritiaWITH2/2D]EIRCAND2➢]3/2D16CACSE[TIDNAH1052FOR]DPSFRESIDENTIALCONSTRUCTION,ANO4O37B-14 f{}R2D, 25 AN4 BD PSF RE5111E)IIHN,,yIDpypAy,� CONSIRULTTON. NOTES TO LOCAL AUTHORITY HAVING JURISDICTION AND ENTITY SUBMITTING DRAWINGS FOR APPROVAL 116E DFTHIS SIT OF PIAM FM ASTTESPEOPIC7'Rag.. L H P OF i+fE IAPIAO W1U. USED s0R A SITE SPECIFIC PROTECT. EACH PADJECTSLF81,1FTTEDiD7}7ELD-_ALALFD{pgnHAYPLG JURLSD;C41045H➢Ltl-0 INCiU➢EONLY THE PEE71NLT[S!icyFEpFKS7 ,UCRIP.ALMMPONDM LOCATED WiTHJNTH[S IAPM�LtSTED EVALUATIONREPpgT. L ALLREIM PE ITAHNG70 AD WSiASIATION (TYPE OF ROOF PANEL, HEADER SPAN, COLU14NM CONNE, DETAILS ETq SH41L BE CIRCLED AND rtsex2+IDENTIFIED BY THE i1FfFT!'S1IWRTI'DR'aTHE OR4W1NC5 FOR APPROVAL 3. PLEASE NCrl'ETHATAS[EL ENMNPE'-'ING CanAm. AND STAMPED THE ORICINAL WMD gEpDeT AS AVAILABLE FROM "0 DIRE00, SUT WAS um INVOSVEO IN MAKING AYYSM SPECIFIC UhMrMNNTH DNSORA iS FOP APP OVAHQSE DAALyNC2 ANY HANOMJSAi',ING OR HIGHLIGHTING ON THE SITE SPECIFIC SET OF DRAWINGSARETHE "DHSIBILM DFTHE ENTRY SUBMF]T'fNG7HEORAWItru� FOP APPROVAL 4, EACHINSYALIATINSHALLBEARAN1DENTiW-T,4GINDICATINGTHENAMEAMADDRESSOFTHEMANUFACTURFRDEIEHL0SD5AtDEI�OSABIUTY_ 5. THEORIGI.NAL IAPMD RETMaFAR5AN E ECTpONICSTAJ 1P FROM WITS ENGINEERING, AnDAW'ETSTAtAF 1S NOT REQUIRED BJ ACCOROANC# WITH THE REDlI1ATFCH STATE➢ BYT1E PRDI-s.SIDNk B0;3m OF ENGINEEPS. B, I L WRY COPE OF TI'E WILLN ORI F NAL VMBAGE3 A8LAC A ]A NIOWPM REPORT 6NDT REQIIfAED. A CDLDR COPY UP THE CDVSTRU;~71OR DOCUMENTS MAY BE REQL'IFIM FSELECTJONS WERE MADE IN A WA77HAT WILL NOT BE VISIBHE O.L' AB[ACK ANDWHITE COPY ATAMHNIMUNLSUBTA6S[UF! FDRA1SLiI%Ec PfRA11If ARUA E5,9D3 LNCIUDE THE FMLOWlK 10"MAMN FROM TFBSEVALUAT*N RDrORT: S TILE SHEET+WDU?YE#ALIWT 2 SMLrMJRAICONTM? iATDN p.e SOLID OP, L"LE ROOF, FREESTANDING OR A7ACHED;.57.xOR Li, 3, BASED 0NTHE REQUIRMDIT2GN LOADS, SHE•SpmRC RAFTER ANRMR PANEL SPAN7ASLEC 4. TYPE OF HLAEEk P=TYPE & WANTRY, FOOTING SZE (WHERE REOLNRRDI LVED ONTHE SITDSPECIFlC DESIGN LOS. AD 5. AaPROPAIRTESTRLk.NRALDFIAl1.5, 6, OTHER DOCUMENTAIIDNTHAT MAYBE REQUIRED BYTHE LOCAL AUTHORITY 7. SEE S3xMUjFOR SmgTpfNy_ HANNGJURISDICTIDN,SUCH ASASITE P1AfL J17? IWAE. I� JOB0 WIND LOAD. - a LIVE I SNOW LOAD: SEE SHEET S1 A OR Ll A FOR SHEET INDEX ALL UNUSED SHEETS SHALL BE REMOVED FROM THIS SET OF DRAWINGS. 11 z )(-ZCI 1 (0 ri, SHEETINDEX I I I r I 1 S COVEi1ICONN�CDOIj o w I I TO BLD�` sma ROTE 2 I I ' a, I a SOLID COVER CONNECTION m s T7 BFiI SEE NOW 2 (E) BUILDING COL, TYP SEE NOTE.4 ' - I I r 1 ' I r I Kw CLE1.R SPAN BEAM CLEAR SPAN LENGTH 'L' SEE NOTE 1 C PLAN YfEW 1 /1 b'=1'-0• NOTES: PATIO- A LENGTH OF STRUCTURE T SHALL NOT BE LESS THAN ITS PROUECT10N 'P'. SEE DESIGN ASSUMPTION NOTE 10 FOR PATIO COWERS CONSISTING OF SOLID CO ERS AND 1AT10E FRAMING. & HEIGHT OF STRUCTURE `FT (TO TOP OF CCrrL i) SHALL NOT BE OYTR 12 Fr. C. BEAM OVERHANG 'OXT SHALL NOT EXCEIM 25% OF BEAMS ADJACENT CLEAR SPAN. EJCCEPTION= NO OVM- WG AJ_GWa AT 19EAM5 CONNECTED TO SIDE OF COL D. SOLID CUAR OVERHANG 'UH' SHALL NOT EXCEED 25Y OF BOTH DECK d IRP SOLID COVER'S ADJACENT C1FAR SPAN, (OR 24' MAXL AT IRP, WHICHEVER IS LBS). E. TRIBUTARY WIDTH ARE AS SHOWN ON PLAN: .TRIG (Bext). k ADJACENT DECK CLEAR SPAN Q RIGHT + DECK OH @ LEFT •TRIB (BLDG)=Yi ADJACENT DECK CLEAR SPAN s01 E Co m A. SEE SHEET S3.1A AND S33 FOR DECK PROFILES AND WAXIMUM SPANS. ' B. SEE SHEET S3.2 FOR DURAPANEL INSULATED STRUCTURAL SAN➢W1CH PANELS MAXIMUM SPANS C. SEE SHEET 521 FOR REDULTON OF SOUD COVER MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEET S32 FOR CONNECTION DF SOLID CW MS TO SUPPORTING UE. WS. E. SEE SHEETS S3.2&S6.1 FOR CONNECTION OF SOLID COVERS TO W SUILDING. F. MINIMUM SLOPE OF SOLID DECK COVERS TO BE PER SHEET 53.1 G, MINIMUM SLOPE OF DURAPANEiS TO BE PER SHEET 53.2. SOLID ROOF PANEL SEE CONCRETE FTG, SEE NOTE 5, Ti? � l80MEIAIC VIEW pjr_'kl 0 �i N EXT. BEAM x SEE NOTE 3 A. SEE SHEETS S4.1 & S4.2 FOR BEAM PROFILES B. SEE SHEET S42 FOR FAN BEAM WHERE OCCURS C. SEE SHEETS S7.1 AND SB.xxx FOR TABLES SHOWING MAXIMUM BEAM SPANS. D. SEE SHEET S2.1 FOR REDUCTION OF BEAN MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS E. SEE SHEETS S6x FOR BEAM CONNECTIONS & DETAILS F. SEE SHEETS 55.1 AND 56.3 FOR BEAM SPLICE DETA:L WHERE REQUIRED, BEAM SIMPLE SPLICE, WHEN NEEDED. SHALL BE LOCATED IMMEOIATEI.Y ABOVE All INTERIOR COLUMN. NO BEAM SPLICE SHALL BE PERMITTED SUWEDi COLUMNS OR ON TOP OF AN MIRIDR COLUMN. 4 COLUMNS A. SEE TABLE 1 ON THIS SHEET FOR MINIMUM NUMBERS OF POSTS REQUIRED BASED ON COVER DIMENSIONS B. SEE SHEET $42 FOR COLUMN PROFILES. C. SEE SHEETS $7.1 AND SB.ru FOR TABLES SHOWING MAMMUM POST SPACING. D. SEE SHEETS S5x AND S7x FOR POSTS CONNECM & DUALS. "• W111-1 A SEE SHEET S7.1 FOR COLUMN CONNECTION 70 FOUNDATION. B. SEE SEAM SPAN TABLES ON SHIEST SB.mr. FOR MINIMUM FOOTING 512E FOR PATIO CCrJER SUPPORTED ON CONCRETE FOOTING, BASED ON BEAM SPAN SELECTED. C. SEE S7.1 FOR ALTERNATE FOOTING SIZES. D. SEE B/S7.1 FOR ATTACHED PATIO COVER SUPPORTED ON SLAB ON GRADE CONCRETE SLAB. SEE NOTE 5 TABLE 1 MNMUM NUMBER OF POSTS FtECIURNG NOTES; 1. NUMBER OF POSTS SHOWN IN 719S TABLE S A V NIMUM, ADD POS-M AS REOUEREDTo ENS URETHATTHE -MAXPOST SPAC NG 1SPANi SHD•NN ON SHEETS Sa. x OR LSxxx IS NOTE=EDED. 2. THI57ABLE LS7D BE USED IN CONUUNC7ION WITH DMILWS" OR 3U-% 3. THIS TABLE DOE$ NOT APPLY VTHE SIDE PLATES ARE PRWDE D FOR AESTHETCAL PURPOSES AND THE SEAR IS CONNEC7EU TO 7HE COLUMN DSRECTLY OR "MN A BRACKET PER 1 ¢" OR LE-3. A TABLE 1 i-MMMUM UM91^R OF COL REQLRRITOCHMENT PER3/SB.3 ORr S H EET INDEX - S OLTD. PA NEL STRUCTURE 5' TYPE A G0.1 -TITLE SHEET, DESIGN LOADS, GENERAL NOTES S1.1 -SOLD PANEL 57RUCTURES:TYPE A 52.1 - SOLID PANEL STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION FACTORS DUE TO DRi7- AND SLIDING SBAA-SOLD PANEL STRUCTURES: ATTACHED COVERS MAXIMUM SPANS AND MNUUM FAS7ENERS S32 -SOLID PANEL STRUCTURES: CROSS SECTIONS SSA - SOLID PANEL STRUCTURES: DURAKNG AND TRIPLE SIX PAN MAXIMUM SPANS AND MINIMUM FASTENERS S4.1 - SOLID PANE L STRUCTUP-ES: 5 EAM PROFILES S4 Z - SOLID P ANEL STRUCTURES: B EAM P ROFILE S S4.9 - SOLID PANEL STRUCTLRES: COLUMN PROFILES 54.4 -SOLD PANEL STRUCTURES' MEM BERS PR OFILES 54.6 -SOLID PANEL STRUCTURES: GCINNECTORS 55.1 -SOLID PANEL STRUCTURES: SPLICE DETAILS S5.1- SOLD P ANE L STRUCTURE": ATTA C HY ENT 70 EXI57NG SUl'- DNO S02 - SOLID PANEL STRUCTURES: CDNNECTIDN DF-7AILS 56.3 - SOLID PANE L STRUCTURES: C ON NE CilDN D E TA E 5 57.1 -SOLID PANEL STRUCTURES: FC,UNDAT ON D ETAES 572 -SOLD PANEL STRUCTURES: FOUNDATION D ETAILS SBxxx- SOLD PANEL STRUCTURES: BERM SPANS AND FOUNDATION SMES xc PSF LL7SL. 1i9 MPH G9.1-ADDTIIONAL STATE UCENSURE STAMPS SOLID PANEL STRUCTURE TYPE A: ATTACHED SINGLE SPAN WITH OPTIONAL CANTILEVER x m T RAFTER (E) BUILDING I SEE NOTE 2 vruuu•rif•�iiii»fiii�i�•ir�ririiu••�1•ri.•..•••••�•.••.� • I 1 I I I I I 1 I I w I I TD BLDG im NOTE 2 ! I 1 f I I I I I I I LATTICE @ 3' DR 6'1 D.C. N I ! SEE NOTE 2 IZ aX � w w COL. TO CL _ I SEE NOTE 4 W I TtAljt7i CONNECTIONI BEAM SEE NOTE 3 I TO Via 3EE MOTE Z I I i ON - BEAM CLEAR SPAN BEAM CLEAR SPAN LENGTH 'L' SEE NOTE 1 3"n � PU1N vl�w NOTES: 1. PATIO COVER ,PENSIONS A. LENGTH OF STRUCTURE 'L' SHALL NOT BE LESS THAN ITS PROJECTION 'P'. SEE DESIGN ASSUMPTION NOTE 10 FOR PATIO COVERS CONSISTING OF SOLID COVERS AND LATTICE FRAMING. B. HEIGHT OF STRUCTURE 'H' (TO TOP OF COVER) SHALL NOT BE OVER 12 FT. C. BEAM OVERHANG 'OH' SHALL NOT EXCEED 25% OF BEAM'S ADJACENT CLEAR SPAN. D. RAFTER OVERHANG 'OH' SHALL NOT EXCEED 25% OF RAFTER'S ADJACENT CLEAR SPAN. E. LATTICE OVERHANG 'OH' SHALL NOT EXCEED 25% OF THE TOTAL UNSPLICED LENGTH OF THE LATTICE MEMBER OR 24", WHICHEVER IN LESS. F. TRIBUTARY WIDTH ARE AS SHOWN ON PLAN: • TRIB (Bext)= X ADJACENT RAFTER CLEAR SPAN @ RIGHT + RAFTER OH @ LEFT • TRIB (BLDG)=X ADJACENT RAFTER CLEAR SPAN A SEE SHEET I-Cl FOR LATTICE PROFILES. B. SEE SHEETS L3.1A & L3.1F FOR RAFTER PROFILES AND MAXIMUM SPANS. C. SEE SHEET L2.1 FOR REDUCTION OF RAFTER MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEET L6.1 FOR CONNECTION OF LATTICE COVERS TO (E) BUILDING. ISOMEITIIC VIEW 3/32"=1'-0" 3. BEAMS A. SEE SHEET L4.1 FOR BEAM PROFILES. B. SEE SHEETS L7,1 & L8.xx.x FOR TABLES SHOWING MAXIMUM BEAM SPAN. C. SEE SHEET L2,1 FOR REDUCTION OF BEAM MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEETS L6.x FOR BEAM CONNECTIONS & DETAILS. 4. COLUMNS A SEE TABLE 1 ON THIS SHEET FOR MINIMUM NUMBERS OF COLUMNS REQUIRED BASED ON COVER DIMENSIONS, B. SEE SHEET L4.2 FOR COLUMN PROFILES. C. SEE SHEETS L7.1 AND L8.xx.x FOR TABLES SHOWING MAXIMUM POST SPACING. D. SEE SHEETS L6.x & L7.x FOR COLUMN CONNECTIONS & DETAfLS. 5. UN'DATI NS A SEE SHEET L7.1 FOR COLUMN CONNECTION TO FOUNDATION. B. SEE BEAM SPAN TABLES ON SHEETS LS.xx.x FOR MINIMUM FOOTING 'SIZE FOR PATIO COVER SUPPORTED ON CONCRETE FOOTING, BASED ON BEAM SPAR SELECTED. C. SEE L7.1 FOR ALTERNATE FOOTING SIZES. D. SEE 8/0.1 FOR ATTACHED PATIO COVER SUPPORTED ON SLAB ON GRADE. I 0 z W x TABLE 1 MINIMUM NUMBER OF POSTS REQUIRING ATTACHMENT PER 31S6.3 OR31L6 3 WITH 2 x 6.5 x 0.032 SIDE PLATES (SIDE PLATE TYPE SP3) TRIG WIDTH WIN 15DB 110C }�qB l2DC 1356 UOC rv' 2 2 2 3 3 3 R 2 3 3 3 3 q 7 2 3 4 4 8 3 4 4 1 $ 3 4 4 4 4 g 1D 3 4 i 6 5 6 17' 4 4 4 5 6 6 7 W TM 2 x 6.5 x 0.D42 SIDE PLATES (SIDE PLATE TYPE SP4) TRTB DS :EDA LVIOSuRE WIDTH 1100 170G 7206 12CC t309 t9GC 5' 2 2 2 2 2 3 2 2 2 3 3 2 3 3 3 3 4 8 2 3 3 4 3 4 9 3 3 3 4 q 5 !lt 3 4 4 4 _4 _5 11' 3 4 a 5 5 5 12, 3 4 1 4 5 s i 5 NOTES: 1. NUMEER OF POSTS SHOW N 1N THIS TABLE 3 A IAINIMUM. ADD POSTS AS REOUI,TED TO ENSURE THAT THE 'MAX POST 5PACING (SPAN1-SHOWN OV SMEFTS S6.xx.x OR LP_yX.x IS NOT EXCEEAF0. 2. THIS TABLE IS TO BE USED IN CONJUNCTION WITH DETAIL 3IS5.3 oR 3!16.3. 3. THI5 TABLE DOE5 NOt APPLY IF THE S IDE PLATES ARE PROVIDED FOR AESTHETCAL PURPOSES AND THE BEAM IS CONNECTED TO THE COLUMN DIRECTLY OR WITH A BRACKET PEA $6.3 OR 0.3. (A*TAIILE 1MINIMUM NUMBER OF COL QUlRIHCi TOP ATTACHMENT SHEET INDEX- LA717CE STRUCTURES TYPE E GO.1-TITLE SHEET, DESIGN LOADS, GENERAL NOTES L1.1- LATTICE STRUCTURES: TYPE E L21- LATTICE STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION FACTORS DUE TO DRIFT ANM SLDING L3.1A - LATTICE STRUCTURES: ATTACHED COVERS RAFTER SPANS L4.1 -LATTICE STRUCTURES: BEAM PRGFILES L42 - LATTICE STRUCTURES: COLUMN PROFILES L4.3 - LATTICE STRUCTURES: CONNECTORS L6.1- LATTICE STRUCTURES-. ATTACHMENTTO EXISTING BUILDING L62 -LATTICE STRUCTURES; CONNECTION DETAILS LG.3 -LATTICE STRUCTURES: CONNECTION DETAILS L7.1- LATTICE STRUCTURES: FOUNDATTON DETAILS L72-LATTICE STRIXTURES: FDUNDATON DETAILS L&xxx - LATTICE STRUCTURES: BEAM SPANS AND F OLIN CATION 62ES m Ps LLISL� 14 MPH G9.1 -ADDITIONAL STATE UCENSURE STAMPS LATTICE COVER STRUCTURE TYPE E; ATTACHED SINGLE SPAN WITH OPTIONAL CANTILEVER tt 2485 RAILROAD ST, CORONA, CA 9288D 951.736.4500 5 5B 5 Tic OF CA tF� DATE SIGNED: JLIEy 06, 2D18 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 �AP M� OTM ES REVISIONS 94RK DATE DESCRIPTION A STEL JOB R 17.1071 DATE A125i78 DRAWN BY RER CHECKED MDS IAPMO 195 V 3.0 LATTICE STRUCTURES: TYPE E Ll . 1 m m RAFTER SEE NOTE 2 (E) BUILDING RAFTER CgNNEC1:IDN a TO BLDG SEE NOTE 2 C — m= LATTICE @ ; 3" OR 6" O.C. 2 SEE NOTE 2 I i I x I COL,,.TYP I l SEE NOTE 4 i m RAFTER COS NE60,'i I To aFwa NOTE 2I I 1 II BAR SPAR I, BEAM CLEAR SPAN LENGTH 'L' SEE NOTE I C PLAN VIEYV NOTES: i PATIO COVER DIMENSIONS A. LENGTH OF STRUCTURE 'L' SHALL NOT BE LESS THAN ITS PRWECTICN 'P'. SEE DESIGN PCSUMPTION NOTE 10 FOR PATIO COVERS CONSISTING OF SOLID COVERS AND LATTICE FRAMING. B. HEIGHT OF STRUCTURE 'H' (T0 TOP OF COVER) SHALL NOT BE OVER 12 FT. C. BEAM OVERHANG 'OH' SHALL NOT EXCEED 2`% OF BEAM'S ADJACEiYT CLEAR SPAN. D. RAFTER OVERHANG 'OFT SHALL NOT EXCEED 25Y OF RAFTER'S ADJACENT CLEAR SPAN. E. LATTICE OVERHANG 'OH' SHALL NOT EXCEED 25% OF THE TOTAL UNSPLICED LENGTH OF THE LATTCE MEMBER OR 2e, WHICH`VER IS LESS, F. TRIBUTARY WIDTH ARE AS SHOWN ON PLAN: • TRIS (BCA)= Ys ADJACENT RAFTER CLEAR SPAN 0 RIGHT + RAFTER OH 0 LEFT • TRIB (Dint)= h ADJACENT RAFTER CLEAR SPAN @ RIGHT + Xt ADJACENT RAFTER CLEAR SPAN 0 LEFT • TRIB (BLDG)=X ADJACENT RAFTER CLEAR SPAN 2- LATTICE COVERS A SEE SHEET L4.1 FOR LATTICE PROFILES. B. SEE SHEETS L3.1A & L3.1F FOR RAFTER PROFILES AND MAXIMUM SPANS. C. SEE SHEET L2.1 FOR REDUCTION OF PJFIER MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEETS LEA FOR CONNECTION OF LATTICE COVERS TO (E) BUILDING. ......1 "..,rou"un n° wnnn rnNrRCIF B IgDMETRiC VIEW 3• BEAMS A SEE SHEET L4.1 FOR BEAM PROFILES. B. SEE SHEETS L7.1 & LB.xx.x FOR TABLES SHOWING MAXIMUM BEAM SPAN. C. SEE SHEET L2.1 FOR REDUCTION OF BEAM MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEETS L6.x FOR BEAM CONNECTIONS & DETAILS. 4. COLUMNS A SEE TABLE 1 ON THIS SHEET FOR MINIMUM NUMBERS OF COLUMNS REQUIRED BASED ON COVER DIMENSIONS. B. SEE SHEET LC2 FOR COLUMN PROFILES. C. SEE SHEETS L7.1 AND L8.mx FOR TABLES SHOWING MAXIMUM POST SPACING. D. SEE SHEETS L6.x & LTx FOR COLUMN CONNECTIONS & DETAILS. 5 FOUNQlTIONS A SEE SHEET ILIA FOR COLUMN CONNECTION TO FOUNDATIDN. B. SEE SEW py CONCRETE FOOTING BAASEDxFOR ON 13DMIIUM FOOTING SPAN SELECTED- C. FOR PA110 COVER C. SEE L7.1 FOR JL'.TERNATE FOOTING SIZES. D. SEE B/L7.1 FOR ATTACHtD PATIO COVER SUPPORTED ON SLAB ON GRADE TABLE 1 MINIMUM NUMBER OF POSTS REQUIRING ATTACHMENT PER"6.3 OR31L6.3 WITH 2 x $,5 Y. 0.03.' SIDE PLATES (SIDE PLATE TYPE SP3) WLTFI2 x 6•� x u,cns aiuc ru. �c� {SIDE PLATETVPE91 T" D PE DAN U WIDTH 1108 13M 130C 12�_2': To" g 2 32 3 4 8 2 3 3 a 4 g 3 3 3 4 4 5 1ST 3 4 4 4 � 5 w 11' 3 4 4 -5 5 6 12 3 4 4 5 6 6 .Y NOTES. 1. NUMBER OF POSTS SHOWN 1NTHE TABLE 13 A MINIMUM. ADC 'MAX POST 6 FACIN G POSTS A5 REO U IRED TO E NSURE THAT THE (SPANrSHOWN ON SHEETS 56.xx.x OR LBxx.x IS NOT EMEEDED. 2. THIS TABLE IS TO BE USED IN CONJUNCTION WITH DETAIL3IS6.3 OR 31L6.3. R' 3. THIS TABLE DOES NOT APPLY IF THE SIDE PLATES ARE PROVIDE D FOR AESTAETICAL PURPOSES AND THE BEAM IS CONNECTED 70 THE COLUMN ❑LRECTLY OR WTH A 0RACKET PER 56,3 OR L6.3, (A)T�AIILE 1 -MINI�ATTAUCMMEN OF COLING TOca 4 AA T IIN] EX - iATTl. TR T R : TYP F GDA -TITLE SHEET, DESIGN LOADS. GENERAL NOTES L12 - LATTICE STRUCTURES: TYPE F L2_1 -LATTICE STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION FACTORS DUE TO DRIFT AND SLIDING L3.1A-LATTICE STRUCTURES: A17ACHPD COVERS RAFTER SPANS L4.1 - LATTICE STRUCTURES: BEAM PROFILES L42-LATTICE STRUCTURES: COLUMN PROFILES L4.3 - LATTICE STRUCTURES: C014NECTORS L&_1 - LATTIC E STRUCTURES: ATTAC HM E NT TO EXISTING E UILD LNG Lag- LATTICE STRUCTURES: CONNECTION DETAILS L6.3-LATTICE STRUCTURES: CONNECTION DETAL.S L7.1 - LATTICE STRUCTURES: FOUNDATION DETAILS L72 - LATTIC E STRUYTURES: FOUNDATION DETALLS Le jox.x - IATTIC E STRUCTURES: BEA M S PANS AND FOUNDATION S IZES xx PS F LLISL,1xO MPH G9.1 -ADDITIONAL STATE LICENSLTRE STAMPS LATTICE COVER STRUCTURE TYPE F: ATTACHED MULTI -SPAN WITH OPTIONAL CANTILEVER ALUMS. ALLOY 3004-H36 ALUM: ALLOY 3004-H36 ALUM. ALLOY 3004-H36 0.042 g 3.000" � 3' x 8' RAFTER 3x8 RAFTER -ATTACHED STRUCTURE LUGSL T SPACING W ND SPEED 1 EXF 8N) 01C 110 B 110 C 120 B 120CI i3D B 130 C 10 0.042 ''s 2414' 29'-V 2$$" 28'-9' 1 29'-W 2V-3' 24' 24'•P 24=1- 24'-2" 23 6' 24'•Er 21 r 20 0.042 i6' Zr-V 2X-D' 23'-Cr 23 tr 234r 22"-9' 24' 1 E'-9' 18'-9" 18'•9' 1$ 9` 18•9' 18'-9' 25 0,042 Is 79$" 19'-8" 24' 16'-7' i5.1' 161•1' 76 1' 16 Y' 1v-1' 30 0.042 16• 18'-1" 1B'-1" 18'•1' 18'•i' 1B-1" 1B`•1• 1_4' 131•9" 13'-9" 131•9` 1 13-9" 13-9 13 r 40 0.042 16' 15-10` 75=70' 75-10' 15'-TO" 15'-10` 1510' 24' 12'-1" 12-1' 7$-t" 12=1" 12'•1' 50 0.042 75' t3$" 73 4' T3'4' 13'A' 13'•4" 17-41 24' 10'•3 I 10-3' 10-3" 10=3' 1 T0'-3" 1O_3" NOTE: IT IS ACCEPTABLE TO SUBSTITUTE: -(2) 3X8 C 32"OC IN LIEU OF (1) 3K8 16"OC -(2) 3X8 9 48"OC IN LIEU OF (1) 3X8 24"OC (2) 2K6 @ 32.00 IN LIEU OF (1) 2K8 16"OC (2) 2X5 L5 48.00 IN LIEU OF (1) 2K6 24"010 T o 0 2 000" 2x6112 RAFTER -ATTACHED S7RUCTQK OIC 0.024 0.032 0.024 `. 1 11- 1w-4• IZ-4" lzm4l_ 1Y';4" 1T- 24' 10'-2' 10'•2` 1p•-2' 7G-2' t0.r IV. 20 0.032 16" 15 8' i5'-B' 15'$' 15' 8' 15' 8' 15'a 24' 12'-10' T� 10. i� i0" 12'-70" i2'-i0' 1.- 0.042 15' Vr-0' 19'JO" 1$-0" 17-0' 19' 0• ifi'-1 24" I5-6• 1 T-v 15'£ 1 S-6' 0.024 16 Sil-r" 1[F-7` 7Q'•7' 17T 1P•7' 10'-i 24' r-1" 9-1' 8'-I' 8'-7' 8'•1' 8-1 25- 25- 0,032 16, 14'$' 14'4• 14'-41 1a a 74'F4" 14'1 24" 11'-1' 11'-i" 1T'•1' 1i=1' 11-1" 17-1 0.042 16" 1r-0" 17 4' 17 4` ir-4' Tr-4- 74 24" 13-3" 13'-3` 137-3• 13.3' 0.074 is" 7-9' 9'a, 9'-9' 91-9. 24" T-B' 7-S• T-V T-6• 30 0.032 i2'3" 42$" 12' G' 12 b" M77-G, 24' 10-2" 1vz 10'-2' 10•2" 0.042 16" 7 S'-O' 16'-D' 16' 0' i 6.0' 24' 12 3" 7 2'-3" 12 ti3" 7 2 3" 12.3 123 0.024 i8" 8'-0' 8'-0' 24' 6-21 O-2' 6•_r 5_ti• fi, 2 E72_' 40 0.032 is 10'-10' f0 t0' 10=10" 10'-10• 10'-10' 10=1( 24' W-3" 8'3• B'•3" 8'3- 8 7' 8-3+ 0.042 1fi' T3'-2" 13'--"' 13.2• 13-2' 13-2' 13':' ' 70'•9' t0'-9' 10'•9" SO'-9' t0-9' 10-9' 0.024 rti3 r3• r•3' T 3" r-3" 24. 5'-Y g'2• 5 =• 5'2' S-2 5.2• 50 0.032 16• 9� 9.9 9' 9 9'-9' rr 9.9' 24. 0.042 ifib 11'-9` 11'-9 11'-9` 11=9` 71•9' i7'� `T o 2.000' I 6.DOD" " 2.000" L # MAX R3 DBL 2' x 8.5' RAFTER 3.=1,-0„ DEL. W 112 RAFTER -ATTACHED STRUCTURE LUGS J 0.024 25 0,032 0,042 0.024 30 D.D32 0.042 0.D24 46 0,032 0.042 0.024 50 0.032 0.042 Olc le, itl 76-2• 1V-2" 1G•2' •17110-10' 10.112 1W-10" 10-TD 14 8" 14'-8' 113' '•9• 1 T-9' 1 T-9' 1 T-3• i r•9' r T' 13'-7' 13'•T 73'-T' 13_T- 2485 RAILROAD ST, CORONA, CA 925BO 951.736.4500 "rESS if S 5 OF DATE CAL 1Fv - DATE SIGNED: July 06, 2018 &.1 7iCL 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305,1150 1 FAX 949.305.1420 iES TM REVISIONS MARK DATE DESCRIPTION 4 STEL dOB # 17-1071 DATE WWII DRAWN BY RER CHECKED MDS IAPM0195 V 3.0 LATTICE STRUCTURES: ATTACHED COVERS RAFTER SPANS L3. 1 A � S' x 8` RAFTEF; a.OW I �Lur�. aLLar 3aDa-��s +AI-1i1. PLLOI' 'JOD�^Fi35 T o u� z.DoO" L2.000' � 2' x 8,� RAFTER 3x8 RAFTER- FREESTANDING STRUCTURE IGSL T 4N SPACING 01C 1108 WINE] 110 C SPEED I W 120 B 120 C 130 1T 254` 2V-" 291ti3 26'•3" 2s- 10 O.D42 Z4' 21'f' 2i'-0' 21'-0' 21 21'- t5 21=10' 21-TD' 21'•1D' 21.10' Zi=' 20 0.1162 24' 1T•10" 11-10 17-10' 1T•iv- 1T� i6' 21'•6'- 21'-5' 21'-0" 21'•2' 21'• 25 0.042 24' 1T-r 1T-7" 1T•7' 1FA. .17', ie, 19'-1' i$'•1" 19'•1" 19.1' i5 30 0.042 24" 15'-r 15'•7' -1 S-T.' 15-7' 15' Is, Tow l6-F t@•8' 19-2" IF 40 0.042 24 1 1Y-- 131•a• 13' 8" 13-v 13' 16. 10{I- 15-0' 15-0" 1S-0' 1S 50 0.042 �m 111•2- 1 11-2' 1i' Z• 11'-Z 11' wya fTIS ACCEFTABLE TO SVBS I TUTS: (2) 3za 32-OC IN 'JEU Of (1) 3x8 0 16'0G 12) 3%B $}49.00 IN LIEU OF (1) 3019 24'DC (2) 2(6 g 32'OC IN LIEU OF (1} 2x6 Q 16`OG (2) a6 a 49'OC 1N LIEU OF 11) 2x6 & 24'OG 2x6112 RAFTER- FREESTANDING STRUCTURE T SPACING W INp SPEED 1 E7sp M 01C ISOB 1t0C 7s0B 520C 5308 0.024 24 16' 10 0.032 24" 0,042 16• 24• 0.024 16" 24' 16, 20 0.032 24" 0.Oa2 16" 24- 1T 0:024 '4- 1� 25 0.032 +s" 0.042 24, 0.024 1 24" IT 30 0.032 '04- 0.042 1 za 0.024 ' 24, 24 6' 40 0.032 11 0.042 24" 0.024 76' 76` SO 0,032 24- 16, 1 S-9• 11'-3' 1 i 1'-3' I1 tL3' g-2' 6'•2' 9'�' $-T s•s s�' s'-s• s'•g 10'-3" 10'�' 17-3' 10'•3" 114' 8�" a'�" V_,r 176 1Zr S7.6' ST-5' 117-7' 1V•2' 1tr2- 17.7' RS R6L. 7 x 8.5' RAFTER 6.000, UAX T 2.000" DBL. W 112 RAFTER- FREESTANDING STRUCTURE T $PAGINv 1NiN❑ SPEE[]! EXf LLIGSL 17H1 OIC 7t0B 11D C 120 B 120 C 73D B 130 C 15` SS-t0' 157-10' 19•SO" 17-10• i9'•10' 19'-• 0.024 za" 167 56-0' IV-Y 16'-0' sE r 15'-10' 16, 2T 25'-3' 25'-3" 253 2S3' 24'-r 10 0.D32 24'�. 2(T•9"6' 20$' 2Q8' 20'-2 15" 30'-=1"25B' 30'•8' 3ff-6' 3Q-0" 30'•a' 29=10' � O.d4_ 24" 251•1' 2S•1- 25-1' «5-1' 2s'd" 1ti" 1E-T" 16=f 7B-r SG7" 1r7' I -r 0.024 2d' 13'-7- 13-r s3'•7- 13-T' i3'-r 13-r T6" 21`-1" 21'-i' 21'-1' 21:1• 21=1' 21'•1• 20 0.032 24" 1T-3' 1T-3" 1T-3' 77�' ST'-1.' 1T•3' 16' 25'-G :5-0' 26 6' 25' £' 2S�i 35'49 O,D42 24. 2U:10' 20-1D' 217•1Ir 2D-10' ZO-IV ZD'-10' 18^ 16-3' S5'-3' 1C•d` 16 t' 15•T is'$" 0.024 24' 9'3- 5-3' ��' 9'.3` 9',3" 16, 20'-S• 20'•9' 2D'•3' 20'6` 201•r 19'-10' 25 0.032 24' 7r-0' 17-0' iT•0- 16+4I• le-V 16'- 16' 26'-1' 1 28-1' 25.5 25.1` 25-1' 25-1" 0.042 24' -0 YO'' 12o-s' 20'-G 20E' 2D'•5' 20'fi IV 14'-W 14' -0' 14'-V 14LV 14'-0' 14'0 0.024 24.11-10' 11'-10' 111.10' 1 t'-1R' 11'-10" 11'-1W 16, 18'4" 11i'•4' 18'-" 18'�" iB-4' 181-V 30 a.032 24' 15-l' 15-1' 15.5' 'IS", 15,-1, 15-1" 16' =-2" 2T-2' 22-7' 22-2` 27-2" 27.7 0.042 24' 1S•-2. 18'-2' 18-r 18'--2' 16-Z' i9=2' t5 ti a' 17-9' 12'-I' 12'-0' 12'$' 12'-a' 0.024 24' 10'-4' 10'-4' 10 4' 10i" tD i0' to, 16=1' 16-1' tG•1' 18 1" 1G 1' S6'•t' 40 0,632 24' t3'•2' 1�-2' 13' 2- 13'-Z' 13'-Z' 13'-Z' 16" 19 a• 115 �" 59' 4^ 19�' 19, 19 i" 0.042 24' 1 W.10• 15• t d' 15.10' 15'-10' 16-10' 1 5'-10 i � 17'�• 13 t'•4' t t'-4" t 1'�' 11=4• i 1'�' 0.024 24' 9.4' 4-4• 9'•a' 9'3' 9'-4' 9'�' ie, 14'-0" T4'•fi' 14'-0' 14 14'•6' ta' 50 0.032 24" 11'-10' St-10' "'-10' 1"-30' 11'-10' 1t'-1D' 16, 1r.• I-r 17--0- 'ITO 17-0' 1T-0" 0.042 24" 14' r i 14s3" 14'•3• 14s3' 14-3' lf-T au-m- ALLOT a0ofxs6 2485 RAILROAD ST, CORONA CA 928BO 951.736.4500 ��F�ss +cat S 58 5 DATE SIGNED: July 06, 2018 C"'A TCL_ 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 REVISIONS MARK I DATE I DESCRIPTION 4 STEL JOB 0 17-1071 DATE 04125118 DRAWN BY RER CHECKED MDS IAPM0195 V 3.0 LATTICE STRUCTURES: FREESTANDING COVERS RAFTER SPANS L3.1 F ALUM. ALLOY 3004-N36 ALUW ALLOY 3oo4-1-{36 STEEL ASTM A653 SS GRADE 5p G6D ALUM. �5 �' 3b ALUAi. ALLOY 3DD4-H38 1.229" 3,000" a 12 GA 2.908" CONTINUOUS p 2D8• 0 D18• STEEL INSERT S�n m D.o42 0 0.042' CO a1 p 3.000" 4 3.000' L3-UDO° L1 2 x 3 LATTICE TUBE3 x 8 x 0.042' ALUM. BEAM WI- — — y GA STL INSERT =1'-0^ 7[.I�.7[..t 3 x 3 x 0"032' ALUM BEAM W/- 3"=1'-0" � 12 GA STL 'U" CiiANHEL 3"=1'-0" ALUM. ALLAY 3DOT 36 ALUM. ALLOY W04-436 STEEL ASTM A653-SS GRADE 50 060 ALUM• ALLOY 34O¢H3S AWIA. ALLOY 3064-1i36 ALUMINUM BEAM do COMINUOUS STEEL INSERT PER B14/S4.2 TYP. D.042° g 0.042' o W TYR 1.500" OR 2.00 LIU 3 GOD" ^ 2.000" 4.000" 2.000" Mtn{: 3.000" 4,OD0' 3.OD0" MAX MAR 1 V2 x 11/2 OR 2 x 2 DBL 3 x 8 x 0.042' ALUR& BEAM LATTICE TUBE s'at' o" BibW/ 14 f3A STL INSERT 3"=1'-0• 012 0BL 3 x $ x 0.042" 317BL 2 x 6 V2 x 0.442' =1.-0�� I'J9 ALU1A, A11GY 3DQ�Fi36 STEEL ASTM A653 55 GRADE 50 C50 ALU}f•+4LLCY 3004-H36 1 229" STEEL ASTM A653 SS GRADE 5D GoD ALUM• A1L01 3D04-+f36 ALUMINUM BEAM k CONTINUOUS STEEL INSERT z PER B14/S4-.2 a 14 GA. TMP• CONTINUOUS STEEL INSERT go g n 0.032" o � o co m n 0.042° TYP. h Typ cv j o 3.000" iL.O00" i ` 3 D00" L3ODO" 4" 2.000" 4.000" 2.000° VAX. �i MAX 3 x 8 x 004r ALUM BEAMJ(��DBL 12 GA STL IN 3"=r-0° Big 3 x 8 X OA42' ALUIJL BEAM WI- DBL 2 x B 112 x 0.03,2' 14 GA STL INZ 3"=V-O" f310 ALUM, ALLOY 3004-H35 NUM. ALLOY 3004-H36 ASTH A500 GRADE E ASST1 A500 CRADE B 3" ALUMINUM OR STEEL POST PER PLAN � t0.032- .041 E,lg n0.1BB'o�p 3.00D" 0.042" 3.000" O =4.00u. F�, 2 O00" 3.000" * 2.OD0" x SEE TfiaLE 1 ON L1.x FOR APPLICATION OF THIS DETAIL HSS 4 x 4 x 3/iS C, HSS 3 x 3 x 3/16 3"=1'-U CIO3"=1'-0' ALU6i. ALLOY W63-T6 ALUM. ALLOY 3004iL3fi ASi►1 A5D0 GRADE H ASTM A5D0 GRADE 3 $ c g 0.046 0.400' 0 0E-§t- o - +R0.1 0.250" 0 0.250' $ ,•;, 45 0 3.OD0" o � 3.000" 3 4,000" L� ff IS ACCEPTABLE COVER THIS COLUMN SECTION (FULL HEIGLiT) BY IT IS ACCEPTABLE i0 COVER -HIS COLUMN SEC710N (FULL ARE HEIG4{TJ BY SECTION CI FOR ASTHEfICAL PURPOSES. NO FASTEl�ERS ARE IEOUIF SLED SHALL D7FND FROM THERPOSES. No FOUNOATION 7 FASTENERS o REQUIRED. SLEEVE SHALL a 7END FROM THE FOUNDATION TO THE L'NOET'SiCE OF THE BEAM/COLUMN CONNECTION. THE BEAM/COLUMN CONNECTION. 3' MAG POST C� 3' SQ. ALUM. POST H33 4 x 4 x 1/4 GS H38 3 x 3 x 1/4 C1i 3"=1'-D"-1 y7EEi A653 GRADE SD GP60 ALUM, ALLOY 3D0¢H35 ASfGI 1150D GRADE H 3' ALUMINUM OR STEEL POST PER PLAN A� N 1.500' p o 0' OACC o N 0.313' e o �RO.12 `D ri 4 �( TYP. r 3.000" 3' c FT IS ACCEPTRBLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) HY SEC110N Cl FOR ArrMETICAL PURPOSES' NO FASTENERS ARE REQUIRED. TABLE 1 ON Lt.x FOR APPLICATION OF THIS DETAIL SLEEVE SHALL EXTEND FROM THE FOUNDATION. TO THE UNDr�i5VOE OF SEE THE BEAM/COLUMN CONNECTION. 3' SCL STEEL POST SP3 0.03� SIDE PLATER C9 HSS 3 x 3 x 5/16 Go 2.875" D.D. • o 0 0 M 0 0 1p g 0.060° N p°0 O r^� a.—ft saw BRACKET IS AV LONG 4 If BRACKET AT COLUMN 'W BRACKET N.T.S. cd � o o 0 p rrp. zog7. p 2.275' C7 LENGTH= 2)�' @ SINGLE 3 x 8 OR 3 x 3 BEAM BELOW LENGTH = &Y4" @ DOUBLE 2 x 15� BEAM BELOW 7,Oprf LENGTH= 8�° @ DOUBLE 3 x B BEAM BELOW 5 ROOF BRACKET LI` BRACKEN L8 x 8 x l/4 x 2' 3°=r-o° 2 '2 x B 17 RAFTER TO BEAM 6 =r-0• Do n D o /n� N V O c Q 0.065' 1n TTp 4 cn � 00' 2.00. 3.315' a LENGTH= Zk" SINGLE 3 x 8 OR 3 x 3 BEAM BELOW &OD" LENGTH= EY4' @ DOUBLE 2 x Ca' BEAM BELOw 2 LENGTH= 6'4' @ DOUBLE 3 x S BFAM BE.Ow 8 sNow BFIACKET `tr BRACKET Lit x 8 x V2 x Z 2•=r-0" 3 3 x 8 RAFTER TO BEAM s"=t'-o° TABLE 1A- MAXWUM PROJECTION 11$ING ROOF BRACKET PER 4CIL4.3 WIND SPEED la en EJTOS URE 30CWGSL121308 1B(PSF) 12DC 20'dIff OTE: 1HEN USING ROOF BRACKET PER 4CJL4.3, MAXIMUM R DJ ECTION SHALL BE T KE SMALLEST P ROJECTION FROM ABLE I AND TABLE 1A TABLE 2 - NUMBER OF SMPSON A345 EA END REQUIRED AT ROOF PANEL OR RAFTER CONNECTED TO EXISTING ROOF OVERHANG (EA. END) TRIS 10 PSF 20 PSF 25 PSF 30 PSF 40 PSF 5D PSF WIDTH WGSL WGSL GSL GSL G5L GSL g 1 1 1 1 1 2 g' 1 1 1 1 2 2 g 1 1 1 1 2 2 19 1 1 1 2 2 2 11' 1 1 2 2 2 2 12' 1 1 2 2 2 2 NOTES: 1 - USE (B) SIMPSON SD9112 SCREWS INTO EACHA34 2- WHEN USING (2) A34s AT EA END, PROVIDE 2x FULL DEPTH WOOD SCAB, FULL LENGTH OF RAFTER TAIL, W/ 10d @ 12' O.C. MAX T&B, STAGGERED (WOOD SCAB TO RAFTER) 3 - A NUMBER 1 N THIS TABLE MEANS THAT 2 A34s TOTAL ARE REO D. A NUMBER 2 IN THIS TABLE MEANS THAT 4 A34s TOTAL ARE REQ`D TABLE4 -ANCHORS NSTALLED NROTHE SIDE OF 6 N THICK MIN CONCRETE OR CMO WALLS CONCRETE, USE 1fr DIA SIMPSON STRONG.SOLT2. STAINLESS STEEL, WITH 3' MIN &BED, INSTALLED PER ICC-ESR-3037. LL STAINLESS STEEL WRH 3 918' MIN EMBED, CMU, USE 11r DIA SIMPSON WEDGE-A STALLED PER ICC-ESR-1396. MAIMUM ANCHOR SPACING 102D, 25 PSF 30 PSF 40 PSF 50 PSF LUGSL GSL GSL GSL 36" 3B- 24' SE 3' SQ.x114' STAINLESS STEEL WASHER WHEN INSTALLING NEW WOOD LEDGER GAINST EJO5TING CONCRETE WALL NOTE WH=N (E) WALL HAS AN CPENING UNDER THE ATTACFOAEN7 OP 171E PATIO TO74E SAVE OR WALL, SITE-SPECI=IC ENGINEER]' IS REOUERED TO VERIFY ADEQUACY OFT HE EXISTING STUD WALL FRAMING {INCLUDING HEADER SIZE) WHENTHE FOLLCWING CONDITIONS OCCUR: FOR LUGSL = 20 PSF MAX; COVER PROJECTION> 1 B' AND OPENING IN WALL WIDER THAN B' FOR GSL= 50 PSF MAX: COVER PROJECTION> 14'AND OPENING IN WALL WIDER THAN E NO ADDITIONAL SITE SPECIFIC ENGINEERING IS REQUIRED WHEN EXISTING OPENINGS I PROJECTIONS ARE SMALLER THAN THOSE STATED ABOVE. ALLOWABLE CLEAR DIMD+iS10N TO SEAM L D SEE TABLE 1A ON 1-6.1 SEE TABLE I ON L6.1 2 x Of or 3 x 8 WOOD FILLED ALUMINUM LEDGER U-BRACKET AND ATTACHMENT PER 2/L6.2 ALUMINUM RAFTER ALTERNATIVE ROOF BRACKET ORIENTATION 4" MIN. }r�" MIN DECK/ OI,EC COLUA BEAM BEAM COLUA TRIBUTARY AREA TRIBUTARY AREA DECK/RAFTER PLAN DIRECTION BM BRACKET w+- "` (E) WALL SEE N.T.S. NOTE ABOVE LEDGER OR WALL E 1' THICK MAX LATH AND E EAVE OH E RAFTER OR TRUSS BACKSPAN HANGER w/ FASTENERS Pi/ufFR OR WOOp SING OR 24 MAX 6-0 WN 40'-0' MA]I PER TABLES 3A & 4 ON 1-6.1 1, 2 OR 3 COATS OF STUCCO SEE NOTE 3 NO TES: RAFTER BRACKET AND 1. EXISTING ROOF DESIGN LOADS: ROL = 3 PSF (MIN) TO 8 PSF (wix) ATTACHMENT PER 2/L6.2 S 2. NEW PAVO DESIGN LOADS: LL = 10 PSF MAX (NO SNOW LOAD) x 3. PLACE "SIKA FLEX' OR SIMILAR MATERIAL BETWEEN BRACKET AND COMPOSITE SHINGLE ROOFING TO PROVIDE SEAL 4. WHEN THE BRACKET IS INSTALLED AT ALTERNATE LOCATION SHOWN. USE TABLE 1 FOR D=5% 5. USE THIS DETAIL WITH ROOF BRACKET PER 5/1-4.3 AND TABLES 1 AND 1A ON 1-6.1. 2xOR 3x CONNECTION TO TOP OF EXISTING ROOF ALUMINUM RAFTER C LL = 10 PSF MAX. 2 x WOOD STUD WALL SIM AT CONCRETE, BRICK NOTE: OR MASONRY WALL 1) WALL LEDGER SHALL BE SEE NOTE ABOVE ALLOWABLE CLEAR DTMENS,DN TO BEAM - NOM'NAL LUMBER SIZE 2 x 6 AT 2 x 6i MINIMUM RAFTERS), SEE TABLE I ON 1-6.1 - NOMINAL LUMBER SIZE 2 x 8 (AT 3 x 8 MINIMUM R.AFTRS), OR - KILN -DRY WbOD-FILLED 2 x b)" OR 3 x B ALUMINU.M SECTION. U BRACKET AND 2) EDGE DISTANCE VARIES WITH DIAMETER OF SCREW. 3 x 8 WOOD FILLED 3) PLYWOOD SHEATHING DOES NOT COUNT TOWARD THIS 1' MAx. ATTACHMENT PER 2/1-6.2 ALUMINUM LEDGER ALUMINUM RAFTER ROOF BRACKET PER 6/1-4.3 $ WA4L CONIVECTIOlV (3) )i"0 LAG SCREWS (3) )i"O LAG SCREWS W/- 4" PENETRATION W/-2;4' PENETRATION D" SE` T ON L6.1 SIMPSON A34 EA ENO SEE TABLE 2 ON L6.1 U-BRACKET AND FOR NUMBER OF A34 READ AT EA END ATTACHMENT PER 2/L6.2 b` E ) BLOCKING BETWEEN CONT. NO RAFTERS OR 6 I TRUSSES ROOF BRACKET PER 5/1-4.3 (3) S-0 LAG SCREWS W/- 1%" PENETRATION (3) )f"0 LAG SCREWS W/- 4- PENETRATION B. ALTERNATIVE ROOF BRACKET MAX. LOCATION AND/OR ORIENTATION SEE NOTE 4 (E) BLOCKING BETWEEN CONT. RAFTERS OR TRUSSES WHERE OCCURS (E) BLOCKING BETWEEN CONT. RAFTERS OR TRUSSES, WHERE OCCURS (E) WALL SEE NOTE ABOVE NOTES: 1. EXISTING ROOF DESIGN LOADS: RDL = 3 PSF (MIN) TO 8 PSF (MAX) 2. NEW PATIO DESIGN LOADS: LL = 50 PSF MAX 3. PLACE "SIKA FLEX" OR SIMILAR MATERIAL BETWEEN BRACKET AND COMPOSITE SHINGLE ROOFING TO PROVIDE SEAL 4. BRACKET MUST BE ORIENTATED TOWARDS ROOF EDGE AS SHOWN. 5, USE THIS DETAIL WITH ROOF BRACKET PER 6/1-4.3 AND TABLES 1 AND 1B ON 1-6.1. 6. VERTICAL LEG OF BRACKET SHALL BE LOCATED 6' MAX. FROM FACE OF WALL, ON EITHER SIDE OF WALL (�)CONNEOTION TO TOP OF EXISTING _ROOF GSL = 50 PSF MAX" CONNECTION TO M) BLN 3/4._,,-O. 2xOR3x ALUMINUM RAFTERS EXISTING FASCIA BOARD ADD 2 x FULL DEPTH WOOD SCAB, WHERE 2434 ARE REQUIRED PER TABLE 2-,ON 1-6:1 SEE NOTE 3 ON L6.1 SAVE OR (E) TRUSS- OR RAFTERS 0 24" CC (E) WALL SEE NOTE ABOVE MIN 40'-0" MAX NOTES: 1. EXISTING ROOF DESIGN LOADS; RDL = 3 PSF (MIN) TO 8 PSF(MAX) RLL/GSL = 10, 20, 25, 30, 40 OR 50 PSF 2. FASTENERS TO BE LOCATED 4" MIN FROM SPLICE IN (E) FASCIA BOARD. 3. SEE NOTE 2 ON TABLE 2/1-6.1. A CONNECTION TO EDGE OF EXISTING ROOF, (E) STUD WALL (3) )i'0 LAG SCREW TYP.- 3' x B" x 0.042" HEADER (3) J14 SMS EA SIDE _LfJ 1" THICK MAX LATH XkI3 t L PUSTil OR WOOD SIDikG OR 1. 2 OR 3 COATS OF STUCCO LL 3"x B" RAFTER BRACKET NOTES: SEE NOTE 6 1. USE OF TH;S DETAIL 15 UMffM TO -WE FOLLOWING; FOR LL/GSL - 10 PSF, MAX TRIO AREA To CONNECTION . 1Do FT2 FOR LL/GSL = 20 OR 25 PSF, MAX TRIO AREA TO CONNECTION = 55 FI2 FOR GSL = 30 PSF, MAX TMB AREA TO CONNECTION - 45 FT2 FOR GSL > 30 PSF, DETAIL IS NOT ALLOWED 2. SEE PLAN FOR DEFINITION OF TRIBUTARY AREA, 3. BEM MUST LINE UP WITH EXISTING FULL HEIGHT WALL STUD. NO OPENING ALLOWED UNDER CONNECTION. 4. USE (2) %" HIM KB-TZ W/ 4" EMBED 0 CONC WALL, W/ 6- SPACING 5. USE 10' TALL BRACKET & (2) h- HILT] KB-3 W/ 4" EMBED @ CMU WALL W/ 8" SPACING 6. PLYWOOD SHEATHING DOES NOT COUNT TOWARD THIS 1" MAX. �l LTWWITH O (N) OR (E) 2 x WOOD ATHING AND LEDGER (LL = 10 PSF MAX CCO OR 2 x OR 3 x WOOD FILLE ALUMINUM MEMBER (GSL = Ys'% x 2' FULL 50 PSF MAX), SEE DETAIL 714 THREADED 4B/L6.2 SCREWS EI1GER TO WALL E ASIEHE85 PER RAFTER PER PLAN I/1,6'2 SMS PER 3/1-6.2, TYP U BRACKET, SIM TO 2/L4.3 OR 3/1-4.3 NOTES: 1. MAX SPAN OF SINGLE RAFTER SW,1.L BE AS FOLLOWS: 10 PSF LL/GSL - 24' FOR 24' AND 16' SPACING 20 PSF LL/GSL - 2Z FOR 24" SPACING, 24' FOR 16' SPACING 25 PSF LL/GSL - 20' FOR 24" SPACING, 24' FOR 16' SPACING 30 PSF LL/GSL - 18' FOR 24' SPACING, 22' FOR 16' SPACING 40 PSF LL/GSL - 12' FOR 24" SPACING, 20' FOR 16' SPACING 50 PSF LL/GSL - 10' FOR 24'' SPACING, 16' FOR 16' SPRING RAFTER TO WALL LEDGER CONNECTION t12 THICKMAX LATH ANnR OR WODD SIpIHGDR QR 3 COATS OF5TLICCOOTE 3 RAFTER PER PLAN FOR LL/SL = 10 PSF, USE (2)114 SMS EA SIDE AND (3) Yi'0 x X' LAG SCREWS. FOR LL/GSL = 20. 25, OR 30 PSF, USE (3)j14 SMS EA SIDE AND (3) %l x 3V' LAG SCREWS. FOR GSL = 40 OR 50 PSF, USE (4)J14 SMS EA SIDE AND (3) X'0 x A7 LAG SCREWS. U BRACKET, SIM TO 2/11.4.3 OR 3/L4.3 ATTACHMENT PER TABLE 3A OR 4 ON L6.1 NOTE: �-- (E) STUD WALL 0 16' O.C. 1. USE LEDGER PER 2/L6.2 WHERE RAFTER SPACING EXCEEDS EXISTING STUD SPACING, SEE TABLE 3 SHEET 1-61. 2. PLYWOOD SHEATHING DOES NOT COUNT TOWARD THIS 1' MAX. S RAFTERECTo " WALL CONNTION 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 F55► ,Q� S585 T� OF CA%- l DATE SIGNED: July 06. 2018 >�� TC� 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 SAP V ES TM REVISIONS MkRK DATE DESCRIPTION 4 STEL JOB A 17-1071 DATE 04/2S�1B DRAWN BY RER CHECKED MDS IAPM0195 V 3.0 LATTICE STRUCTURES: CONNECTION DETAILS L6.2 LATTICE ATTACHMENT PER #B SMS 7/L6.3 3 x 8 x 0.42 BEAM OR 3' SQ. STEEL BEAM DOUBLE BEAM (4) #14 SMS EA (6)-J14 SOS 0 E4 SIDE B9, BID, B12, WAFTER TO COLUMNF— \—TOP k BOT TOTAL = 24 B15 OR B16 (8 TOTAL) l S0. OR 2' S0. OR 5/8'0 HOLE WITH 2 x 3" LATTICE @ 3' H BRACKET PER 1/54.5 MIN. UP TO 6' D.C. M D.C..0 I $ I PLASTIC PLUG, AS OR 1/L4.3 REO'D, TYP. IT IS ACCEPTABLE TO USE 3' OR 4" SQ. RAFTER I I ONE HOLE TO ALUM. OR STEEL POST I INSTALL SEVERAL I } SCREWS, TYP. (3) #14 SMS 3 x 3 x .024 EACH SIDE CONNECTOR TH S DETAIL IS NOT TO BE USED IN LIEU OF A COLUMN. i LATT}CE TUBE TO RAFTER STUB COLUMN TO DBL BEAM i *w BRACKET TO POST 7 3"=1'-0" CONNECTION 1-1/2"=V-o" 3.125' FOR 3 x RAFTER LAjTllCE ATTACHMENT PER 7/L6.3 1 2" 1�A4X 5PLl0F 7--T7-111' FOR 2 x RAFTER WHERE OCCURS (6)$14 SMS p EACH (INT COL ONLY) t=0.040' @ 6063-76 HEADER TO COLUMN DOUBLE BEAM B9, DBL RAFTER (12) FASTENERS PER B10, B12, B15 OR (4) 114 SMS EA RAFTER CONNECT" B16 TO COLUMN (B TOTAL) 5/8'q HOLE WITH II j 5/8"0 HOLE WITH PLASTIC PLASTIC PLUG, AS I 11 I PLUG, AS REO'D, TYP. IT IS REO'D, TYP. R ISLj I I ACCEPTABLE TO USE ONE ACCEPTABLE TO o p p HOLE TO INSTALL SEVERAL USE ONE HOLE 1 I SCREWS, TYP. TO INSTALL SEVERAL SCREWS,HTYP.in ATTACHMENTS PER 2/L6.3 0 � { (2)#14 SMS EACHSIDE T&B 03VARCHrrECTURAL SIDE BB5 ORR B1fi , B10, B12, U.C. PLATES, WHERE OCCUR, I6EL W 6EWk FLUSH ylyf3 k 3" OR 4' SD. POSE W/ OPTIONAL SIDE PLATE OR 3" OR 4" S0. POST ARCH COL WHERE OCCURS BRACKET A8L BEAM TO COL SCALE: D8L RARER TO DBL BEAM. 2 CONNECTIOt�f =1'-0" 1-1/2°=1' 0" 1-1/2 (2)414 x Y4' TEK SCREWS 3" WIDE BEAM TYP 82, RAFTER EACH SIDE BRACKET TO 95, 811, 813 OR Ell rfl'ER � SPUOE RAFTER 3" OR 8" BEAM (6) J14 SMS EA. SIDE E OCCURS SMS PER ELEVASIDE TYP-AT SIDE PLATE SP3 COL O1JLY) (B) J14 SIASS Ek SIDE a LO Wo PLASTIC AT SIDE PLAT SP4. SEE NOTE 1. BRACKET PER (4)-j14 x Y4" TEK SCREWS BRACKET TO BEAMPROVIDE FULL BEARING OF#• 2/L4.3 OR 3/L4.3 w BEAM ON POST. u SINGLE 3 x 8 OR 3 x 3 BEAM %-0 HOLE WITH PLASTIC PLUG, ASREO'D, TYP. IT IS ACCEPTALT E TO ° °SIDE PLATUSE ONE HOLE TO INSTALL SEVERAL SCREWS, TYP.(2)-i14 x TEK SCREWS(2) 114 SMS EA SIDE ATbuz" SIDE PLAIE EA. SIDE SEE RAFTER EACH SIDE BRACKET TO TABLE 1 ON S1.x OR L1.x RAFTER 3' SQ. POSTBOTTOV AND AT 32' OC MAX. (2)- 14 z 3i" TEK SCREWS SIDE PLATES OPTIONAL STYROFOAM INFILL OF A EUWAXIN SIDE PLATES BRACKET TO EACH BEAM -- 2 3" SQ. POST BETWEEN THE CON ECIOON STOP BELOW t�e (4) TOTAL SIDE PLATES DBL 2 x 6 BEAM BELOW OR DBL 3 x 8 BEAM BELOW mm RAFTER BRACKET 3 BEAM TO POST CONNECTION AT COLUMN 02, ADJUST SCREW LOCATION TO LOCATE SCREWS (�-�CONNEC'TION^=1'-D° 1NIO THE FLAT PORnON / VERT1CAf WALL OF BI AM STEEL SLEEVE PER 4/0.2 AT POST TYPE C7, C8, & C9 BOLTS PER TABLE 2 ADJACENT GRADE TIP 3' OR 4" STEEL POST. GRADADJAENT GRADE TIP. ,�1-1 ° Ii TABLE 1 ALTERNATE FOOTING DIMENSIONS FTG(IN) Alt AIt2 AA3(ATTACHED) At4 At5 Alt6 AIt7 W=L-D WxLxD WxLxD WxLxIB" WxLx1B" WxLx24" WxLx3O' WxLx36" (SEE NOTE I) ISL<N07E2) (5EENOTE 3) (SEE NOTE 4) {SEENOTES) (SEE NOTES) (SEE NOTE7) (SEE NOTE8) IB 19xIsxIs 17x12x12 18K18xis 28928x18 16x16x24 14x14x30 13x23x36 20 20x20x20 12x12x12 21x21xI8 25x2Sx19 29x19X24 17x17x30 15x15x36 zz 22x22x22 16x16x16 25x25x18 33x33x18 21x21x24 19x19x30 17x17x36 At8 WxLx42" (SEE NOTE9) 12x12x42 44x14x42 16x26x42 ,I a .• I _ �� } ��'�) •a ' ' • . I� • 24 24x24x24 20x20x20 28x28x18 43x43x18 24x24x24 22x22x30 20x20x36 26 SBx18x42 • i� _ 3•A41N. ` 26M26X26 23x23x23 32x32x18 31x31x24 24x2Rx30 22x22x36 2B 28x28x2B 21x21x42 • + z 2Sx2Sx2S 35x35x18 38x38x24 27x27x30 25x25x36 30 23x23x42 PER 4/0-2 - x ¢ • • - a . 4 y �� 30x30x30 28x28x28 39x39x18 30x3Dx30 28x28x36 26x26x42 • `• a. =a + ` w~ ' a 32 32x3Zx32 30x3px30 43x43x16 37x37x30 30x30x36 34 2Bx26x42 _ .- w �9 • 'g,• . cia �: 34x34x34 32x32x32 47x47x1B 33x33x36 31x31x42 ,- • a • - • A + , m o o ti _a �m 36 36x36x35 34x34x34 S1x51x18 36x36x36 38 38x38x36 34x34x42 4 37x37x37 55x55x18 43 ` - - _ a x43x36 4D 40x40x40 39x39x39 60x60x1B 36x36x42 ' . I- • • I '` • a' .t ��� :2 42x42x42 41z47x41 64x64x18 39 x39x42 POURETE'� ' I I I I ED ' E I I' 42x42x42 ONCPOU CONRCRETE ` ' I' Tip q A36 THREADED NOTES: FDDTING FOOTING ROD W/- NUT EA SIDE 1- "FTG 4N)" IS THE FOOTING DIMENSION REFERENCED IN BEAM SPAN TABLES ON SHEETS 5B,,x OR LBxx.x. WIDTH =LENGTH EN OF COL OR WjC1TH #4 RED 2-'AL1 15THE FOOTING DIMENSIONBASED ONTHE "FTG(M)"DIMSI:51ON.NDTETHATW=D� "AL72" - 40 MIN. SECURED G 3 - 15 THE ALTERNATE FDDTING DI MEFISION REgUIRED W HEh A3 S" MIN THICK SLAB 15 PRESENT ABOVE THE FOOTING. NOTETHAT W L "A.T3" IN BEAM SPAN TABLES IN IN BEAM SPAN TABLES IN PLACE 4 - 15 THE ALTERNATE FOOTING DI MENSION REQUIRED WHEN THE FOOTING 15 KEPTTO AN 18" DEPTH FOR UPLIFTDESIGN ONLY.THIS VALUE ONLY ATATTACHEOPA'HOSTRUCTURES. NOTE THAT- W-LArXD-18', ISTO BE USED NOTES: NOTES; S-'ALT4^ 15 THEALTERNAT-t FOOTING 01MEN51 ON REQUI RID WHEN THE FOOTING IS KPTTD AN IS- DEPTH. NOTE THAT W=LAND D=IB-. 1. THIS DETAIL CAN BE USED FOR STEEL POST TYPES C6, C7, C8, OR C9. I. THIS DETAIL IS TO BE USED FOR POST TYPES CIO & C11. 6- ALT5'15THEALTERNATEFOOTING DIME151ONK-CLUIREDWHEN THE FDST:NG15KPTTOAN24"DEPTH. NOTE THATWdANDD•24". "ALT 2. THIS DETAIL SHALL NOT BE USED FOR STEEL POST TYPES C1, C2, OR C5. 2. THIS DETAIL CAN ALSO BE USED FOR STEEL POST TYPES C6, C7, C8, C9 7 6' 15 7HEALTiRNATE FOOTING DI MEN.91ON RMU1 10 WHEN -HE FOOT ING IS KEPT To 3. IT IS ACCEPTABLE TO EMBED THE STEEL POST DIRECTLY INTO THE FOOTING PER TABU= 2 ON L7.1. B-'U77"15THE ALTmNAT2 OOTINGDIMENSION R OUIRLD WHENTHEPD"NGISK PTTOAN36"DEPTH.NDTETHATW3ANDD=36". PER 5/0.1 INSTEAD OF USING THE POST SLEEVE SHOWN IN THIS DETAIL 3. THIS DETAIL SHALL NOT BE USED FOR ALUMINUM POST TYPES C1, C2, 9--AL78"ISTHE ALTERVA_EfODTTNG01MENVONRMUIREDWHEN THE F"DOTINGISKEPTTOAN42'DEPTH. NOTE THATW=LANDD=42". OR C5. &MSTEEOL POST SLEEVE CONNECTION STEEL POST EMBEDDED CNCRETE FOOTING 1•Qi'-0• INTO CONCRETE FOOTING - 1"=1'-o" >� TABLE 3 - (MAX WIND SPEED:130MPH, EXP C) MAXIMUM POST SPACING WHEN PATIO COVER IS INSTALLED ON SLAB ON GRADE TRIB WIDTH LATTI CE FRAMI NG LLJGSL(psfi GSL(psf) 10 psf 20 psf 25 psf 30 psf S. 13'-7" 11'-0" 10'4" 9'-0" 6' 11'4" 91-9" 9'4)" 8'4" 7' 91-8" W-0" 81•0" 7'-6• 8' 8'-6" 81-6" 7'-S' 7'-0" 9' T-7" B'-0" 7'-W NP 10' 6'-9" 7'-0" N.P. NP 11' 6'-2" 7'-0" NP NP 12, S1-8' W-6- NP NP 3 STEEL OR ALUMINUM POST TABLE 2-ANCHORAGE SCHEDULE (ATTACHED STRUCTURES ONLY) 7 BRACKET PER 1/1.7.2, 2/L7.2, BRACKET DETAIL POSTTYPE ANCHOR BOLTS SEE 3" STEEL OR OR 3/L7-2- ;5E5NOTE2) NOTES ALUMINUM POST ADJACEHi GRADE ,T BRACKET PER 1/L7.2, ALUM 7 ALUM 1/L7,2 CI 18" dla wl 1-7J8" embed *ALLf2)-3/8m BOLTS PER TABLE 2 WHERE OCCURS 2/L7.2 OR 3/L7.2 T 10.2 Cl 18" dia w/ 2-7/8' embed ALUM T z �L7 2 a J8' dia w/ 1.7/8' embed 3 S' Ek15i1N OR NEW SLAB ON ALUM T 2J17-2 C2 dia w12-7/8' embed 3 IaIN, ° GRADE. f'c=2,500 PSI MIN. PLUM T 2/ 7,2 CS SOG (2)-3/8"diaw/1-7/8"embed 3 ADJACENT GRADETYP. ALUM T 2/L7-Y CS ALL (2j-3; 8" dla w/ 2.718" embed 3 ° " • ;° . STEELY 3/llLL C6 SOG {2P3J8• dia wJ 1-]J3' embed • i * iE STEELY 3J17,2 C6 522' {2)_3/8'd1aw/2-7/8-embed 1,3,4 fI I a= �I-T I L SLAB STEELY STEEL INS 3/E7-2 4/17.2 C6 s24" (2)-112" dia wJ 3.1/4' embed 1,3,4 x �� -DF WHERE.000URS BOLTS PER TABLE 2 C6 530" (4)-1J2"dia w/ 3-IJ4' embed 1,4 • w aJ RED CONCRETE FOOTING STEEL INS 4/L7,2 [6 534' (4)-5/8'dlaw/4"embed 1.4 _ a STEELINS 4/L7,2 C6 23S" (41.3/4'diaw/4-31A"embed 1,4 0 NOTES: STEEL INS 4JL7,2 C7, CB, C9 ALL (4)-3J4' dia w/ 4-3/4' embed S,S r` m 1-"NP" INDICATES THATAFOOTINGISREQUIRED, AND THE PATIO NOTES' I. THIS DETAIL CAN BE USED WffH POST TYPES C1, C2, C3, C5, OR C6. EMBED I 5/L7,1 C10,CI1 ALL WA • ° COVER CAN NOT BE SUPPORTED ON A SLAB ON GRADE. 2- FOR LIVE ORSNOW LOADS HIGHERTHAN THE ONES SHOW NON 2. THIS DETAL SHALL NOT 13E USED FOR METSTANDING STRUCTURES ANO/QR C01IMF1fCIA1 APPLICATIO 5. NOTES. 1-"FTG(IN)"ISTHEFOOTINGDIMENSIONREFERENCEDINBEAMSPANTABLFSON %1% LENGTH IN THIS TABLE A FOOTING IS REQUIRED AND THE PA O COVER CANNOT 3. THIS DETAIL SHALL NOT BE USED FOR POST TYPE C7, C8, C9, CIO, SHEETS LSxxx SEE FTG- 5CF[Ef](1[E BEAM SPAN TABLE BE INSTALLED ON SLAB ON GRADE- Q 1 1- 2 -ANCHOR BOLTS SHALL B E 51 MPSON STRONG BOLT 2, STAI NLESS STEEL (ICC-ESR 3 -WHEN THE PATIO COVER IS INSTALLED ON A SLAB ON GRADE 4. SLAB ON GRADE SHALL BE IN GOOD CONDITION (NO VISIBLE CRACKS 3037) NOTES' (RESIDE1MALAPPUCATIONSONLY),THE MAXIMUM POSTSPACINGIS WITHIN 12" FROM POST). 3-IT IsACCEFTpsLEToUSE THESTEELINSERTP;R4/L7.2INSTEAD OFTHE I. THIS DETAIL SHALL NOT BE USED FOR FREESTANDING STRUCTURES. THE LOWEST OF THE"MAX POST SPACING(SPAN)"SHOWN ABOVE 5. MINIMUM OVERALL DIMENSION OF SLAB ON GRADE SHALL BE PER ALUMINUM TPER 2/L7.2 FOR PDSTTYPES C2 AND C5. BOLTS CAN CAN REMAIN AS 2, THIS DETAIL SHALL NOT BE USED FOR POST TYPE C7, C8, C9, CID, AND THE MAXIMUM P05TSPACINGSSHOWN ONSHEE-rLBJ(X.X FOOTING NOTE 4 ON GO.1 SPECiFIEDlN7H15TABLE. C11- 4 - IT IS ACCEPTABLE TO USE THE EM0 EDDED POST DETAI L 5/L7 a I NSTEAD O F 1T' E STEEL INSERT OR STE ELT FOR STEEL P0575 C6. 5 - IT 15 ACCEPTABLE TO USE THE EMBEDDED P05T DETAI L 5/1.7a I INSTEAD OF TH E STEELIN5ERT FOR STEEL POS75 C7, C8 AND C9. T BRACKET CONNECTiON B CONE TO SLAC ON I' =1'-0" (�) AN0H0RA11E OF POSTS BRACI[ET CDHN>ECiIOH TO SLAB OR FOOTING (�)T TO CONCRETE FOOTING 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 EMI K S 58 5 •P)� OF GAL lF DATE SIGNED: July C6, 2C' f; A-:VAP hr��d 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 SAP WTM ES REVISIONS MARK DATE I DESCRIPTION 4 STEL JOB R 17.11371 DATE 04125118 DRAWN BY RER CHECKED MDS IAPMO 195 V 3.0 LATTICE STRUCTURES: FOUNDATION DETAILS U.1 ASTM A500 GRADE 6 1t'L'M ASiOY 64fi3 76 N � (4)-J14 SMS 2 OR TSCREWS � w � NSFITT TO 1 ' EA SIDE, TYP.PLAN :ii BASE PL 3" STEEL POST c N L )"0 HOLE EA. SIDE --- 0.188' THICK MIN HSS INSERT I 0,085' TYR I - (3) -wo BOLTS 5.662" T17. —1 if S0. x %, BASE PL - T.O.C. I BRACKET LETIGTH 15 275" 2. THIS BRACKET IS TO 13E USED WITH POST TYPE C1, WTrr1 OR WITHOUT NO ; ELEVATION SIDE PLATES PER SP3 OR SP4. 1. THIS BRACKET 15 TO BE USED WITH POST TYPE C7, C8 do C9, AND WITH C6 3. SEE TABLE 2 ON L7,1 FOR ATTACHMENT TO FOOTING/SLAB. (WHEN FOOTING ON SIZE IS W OR FOR TTALARUER TO FOOTING/SLAB. 4• INSTALL 1Y x 1Y x 36 HDG WASHER PLATE AT ANC 2. HORS FOR 130 MPH KMENr 3. INSTALL 1Y x 1Y4 x J6 HOG WELDED WASHER PLATE AT ANCHORS SMALLER THAN Y4 "0. 4 THIS ES) ON BRACKET N A ABL2BEUSSEDSFOR PST /TYP; C2, C5, OR C6 (ALL FOOTING (�)MOR pD8T SLEEVE sts C7, M Cs 3/4°=1'-0" ALUM ALLOY 6063-T6 4-114 SMS OR SITED ,TREWS, I L"0 HOLE EA. SIDE 0.094 TY7�__�0.75(�r L5.50" NOTES 1. BRACKET LENGTH 1S 2.7V. 2, THIS BRACKET 15 TO BE USED WITH POST TYPE C2 OR C5, WITH OR WITHOUT SIDE PLATES PER SP3 OR SP4. 3. SEE TABLE 2 ON L7.1 FOR ATTACHMENT TO FODUNG/SLAB. 4. BALL lYt x A 06 HOG WASHER PLATE AT ANCHORS FOR 13G MPH. 5. STEEL TICKET PER 3/L7.2 CAN BE USED IN UEU OF THIS BRACKET. M T-BRACKET DIF%OMPOSTS C, C6 0.75" 4.00" Z AS00 GRADE B 1.75' x 0 HOLES c 1 Xo"0 k 2-%6 D 0� � � HOLES, TYP EA SIDE o 0 O 0 0 0 PLAN 2,� ` 3.50" TP 2-3(6 0 HOLES FOR —Q c %"0 M.B. TYP. N N ELEVATION NOTES: 1. THIS BRACKET IS TO BE USED WITH POST TYPE C6 WHEN FOOTING SIZE IS 24" OR SIOLLER, WITH OR WITHOUT SIDE PLATES PER SP3 OR SP4. 2. BRACKET CAN ALSO BE USED WITH POST TYPE C2 OR C5 PER TABLE 2 ON L7.1 AND 2/L7.1 3. SEE TABLE 2 ON L7.1 FOR ATTACHMENT TO FOOTING/SLAB. 8 STEEL IT-BRACKET PAST CB 3"=1' 0" 24B5 RAILROAD ST, CORONA, CA 92880 951.736.4500 ��Y, I S 5885 9T>" OF CA1-YF� DATE SIGNED: July 06, 2018 V'wry 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 REVISIONS DESCRIPTION 4 STEL JOB # 17.1071 DATE 041291E III DRAWN BY RER CHECKED MDS IAPM0195 V 3.0 LATTICE STRUCTURES: FOUNDATION DETAILS ATTACHED & FREESTANDING LATTICE COVERS -10 PSF SNOW LOAD OR LIVE LOAD -110 MPH - EXP. B & C BS 3"SQ. ALUM W/ B9 8 DSL2x6.5xO.042 81; 12GASTL"U"CHANNEL 3x8x0.042 B;0 D8L2x6.5x0.032 B12 DBL3x8xD.042 B73 3x8x0.042W/ ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING 14 GA STL INSERT MAX MIN MAX MIN MAX MIN MAX MAX MAX A7 C—HEO FREESTANOING ATTACHEp FREESTAND A7iACHED FREESTANDING TRIB VIDTH WIND F� POST SPACING FTG POST POST POST POST PAST POST FIG MIN POST POST F.G MIN POST POST FTG MINLFTG POST MIN MAX MIN MAX MIN MAX MAX MAX (SPAN) (IN) TYPE SPACING OM (IM TYPE SPACING (IN) ON) TYPE SPACING (IN) TYPE SPACING (N) TYPE SPACING ON) POSTPOST POST SPACING FTG POST POST FTG POST POST FTG MIN POST POST FTG MIN POST POST FTC, MIN (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) TYPETYPE (SPAN) I (M TYPE S ACING (N) TYPE SPACING (N) APE SPACING (IN) SPACING QN) POS1 5 1106 iS-9 15 Cl 14'T 29 C7 14'-10^ 15 Ci 74'-10" 28 CT 15"4^ t5 15-0" (SPAN) (SPAN) (SPAN) TYPE 18=9 17 14'-7' 3t CB 14'117' 17 i4'S 30 S5�" 17 C1 15=1" 30 C7C1 1829 CT 21'-0" 1B el'Hi" 31 C7 21) 6" 1 18 C1 73'3' 28 C7 19=T' 13 T3=T' 28 74'•}^ 7g i4'_}" 2B 1r� 31 2rs' 1s Ci 21-2' 39 CS 20-8" 19110C c16 20.9 31 C7 110 C 1S3" 78 13'�' 30 C8 13-7" 1T 13'-3' 29 CT 1C 7" 17 C1 C7C1 98'� 28 +.8-9' 17ti17C1 18 2U2^ 33 CB 7 110 6 I4'-2' 16 Ci S7�" 28 C7 12'-T' i5 12� 28 73'-1" I5 73'.g• 13=1" 18'0 30 C7 1g'_ 9 1@ C2 19'-3" 32 C7 7E}-0 3007 11DC 1A-2. Te 12W- 30 12'-T' 1T C1 i2� 29 C7 13'•1' 17 Cl 28 C7 15-7' 16 C1 is_� 29 1B'� 17 18�" 3D 18-0" S9 18�" 32 !3 17RE3 13 :6 C1 11-i 29 C7 ills" 1B 11-0" 28 T2S" 78 12'-9" 29 15',2' 18 1A-f17' 30 C7 18'4^ 20 C2 17=1{1 31 CT i7=T' 17 iT-7" 30 C7 i50 C 19 3 19 11 T' 29 11'-0" 1B 1 71 2B C7 72-9 18 Ci i2 9" 28 C7 14-3' iT C7 14'�" 29 17.2 1B 1T-2 31 1T-7" iB TT-S" g1 9 110B 177" T7 C2 77 0 29 CT 57-2 iB 11'2 28 1}_T 18 1Z-p' Za 14-° 19 _ 13 CT 17'-7 2n C2 15-9 3i C7 7fi-0 18 C2 1B$" 37 C7 110 C 17-T 19 1 T T 29 11-x' 16 C1 10'-10" 28 CT 11'-7" 7 B C1 11=T' 11'3" 2g OT 73'�' 17 CZ So- 18'S" 18 76'3'" 31 16� 20 18-1' 3S 10, 1140 1x0 17 C2 10A" 30 C7 1Q7" f8 C1 7n'-7" 28 11-0 16 f1'U" 28 2i1 13'-0"' 19 13=1" 30 C7 16'ti9 2f C5 31 CT 15'S T5$ 1E C2 15'S^ 31 C7 110 C 12 R 19 t0'A" 30 10'-7" 1$ in-3^ 29 CT 1147 19 Cl i0:8 79 C7 12-5 TT C2 12 9 30 C7 15 4 18 15�" 32 14-9" 20 15-2' 31 11' 1i0 B f1'�" 17 C2 9-10 30 C8 10. 1" 17 10-1" 29 1n'� 17 16'�i 29 12,_2. 2015'~" 21 C5 75=1" 32 C7 18 CS T4_g- 32 C7 71DC S7'�" 20 81n 30 10=1" 18 C1 9'-10" 29 C7 10E 19 CT 10=7" 2B C7 72'?' 18 C2 12=2 31 C7 14'e'" 1B 148" 32 IS, 9" 21 144d" 32 12' 710 B SG-70" 18 C2 5� 30 CB 9'$ 17 8'-0" 9'-0" 77 9'-B" 12 7' 20 11'-i0 30 14'$ 2S C5 14'�" 32 C7 :4-7" T9 CS 1d'-i" 32 C7 1 to C 10 10" 20 Ste" 30 @-0 18 C2 C7 29 T1�" 18 14-1"' 2T 13'$" 32 11'�" 37 14=1" 22 13-9" CT C7 32 73'8' 27 13'2" 32 NOTES: 1 - WHEN THE PATIO COVER IS INS7ALLED ON A SLAB ON GRADE (RESIDENTIAL APPLICATIONS ONLY), THE MAX -MUM POST SPACING IS THE LOWEST OF THE 'MAY, POSTS PACING (SPA NY- SHOWN ABOVE AND THE MA4MUM POST SPACINGS SHOWN ON DETAIL W0.1 2 - IT IS ACCEPTABLE TO SUST1TUiE COLUMNS W/ HIGHER NUM BERSW1 THOSE SPECIFIED IN THE TABLES SHOWN. ATTA CHED & FREESTANDING LATTICE COVERS -10 PSF SNOW LOAD OR LIVE LOAD - 120 MPH - EXP. B & C B9 DBL 2 x6.5 x 0.042 $i1 3x8xD.04239 B10 DBL2x6.5x0.032 B12 DBL 3xBx0.042 B13 3x8x0.042W1 14 GA STL INSERT 3"SQ. ALUM W! 85 12 GA STL"U" CHANNEL - FREESTANOING ATTACHED FREESTANDING ATTACHED FREESTANDING FREESTANDING A�ACHED FFiEESTAN'DING ATTACHEED FREFSTANAItJG ATTACHED MAX MAX MAX MAX MIN.POST MAX MAX FTG MIN. ATTACHED MAX MAX MIN. L MAX MIN. MAX MAXMIN FTC'' MIN. MAX POST FTG. MIN POST G• MIN. POST POST 1 p05T (IN POST SPAC NG ON) S N) POST E TR1B WIND POST FTG. MIN. P09T POST F7tt POST POST M. PYP� POST SPACING FfG- ON.) OST POST SSACWG ON.) PCST SPACING (IN.) POST TYPE ON) TYPE SPACING NG )TYPE SPACING (N TYPE SPACING (SPAN) TYPE (SPAN) TYPE SPAN) VIDTH EXP. SPACING (IN.) Tl'P£ SPACING ON.) TypE SPACING ON.) TYPE ( PAN) TypE SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) C1 C9 20�" 20 C1 B» 34 CS #206 18 6' 16 14'-T 31 C8 14-#C 15 C1 14 Ir 30 C7 15 C1 14 7` Si C7 IT'S, 19 C1 TT-0 31 Ca Z7 4" 20 20'7" 34 C7 #94" 18 G1 19-0" 32 C7 5' 12DC iS�" 18 C1 14-7' 39 C#0 14'8 78 14'-#" 31 151.2" 14-7" 1t 16 14-1" 29 15 C1 15�,. 3° C7 18'!7' 1a Cz 19=5' 19=9 32 34 CS 1B�" Za C2 18 0 33 C8 12(I B 15-3^ 13'3' 30 C8 ITT, 1B —I C7 IT-T' 29 13-10^ 18 C7 13 4" 37 C7 16'2' 19 �9 1$ 4" 31 1T-T' 18 1T T 31 8 Inc8 15-0 Cl 13-3' 32 C9 IT-4^ a— 12^I0•' 31 2& 13'-1" 76 13-1" 29 C7 15-2 17 C1 30 C7 #8'� 21 C2 1T 4" 33 C$ TT 3" 24 1B 8 33 12D B 74=T r17 C7 # 1" 29 C7 —co— 1T-7• 16 C7 72 7" 12-0 37 C7 17: 0 79 C1 3D 1sIJ 2D 14�' 33 1e'-s' 19 1T-2" 31 75� 1a 1 C7 rIra t3 1U #24" 31 72�' 19 1 `$ 77 12' 2& C7129Ct3fl" 74=3" 18 C7 14'-3" 29 CT 17�' C7 13'3 C1 17=7' Z9 C7 i1'-9" 1T C7 17'2' 30 C7 i21" 19 C1 11'7" 3D 14-1" 2U G2 ice$ 16-3 31 31 C7 8 17-T' 31 S 17'8 79 11' 2' 28 71' 7" 77 C7 1 2� 1S B C7 #8'3 1B� OS 15�" 32 C7 153" x2 1A$ 32 12 S 1Z 7 78 C2 I T-U' 29 CT 11,T` 17 C1 70 7" 2$ C7 17'�4" 20 cy 11 �] 29 ar 17�9 30 1S 4' 1$ i5i4' 3Y t4�9" 78 CS 1-0' 9 31 CT 5 12 0C 12� 20 iT-0' 3o Ca 71'-0 20 29 11' 0 17 71 ?9 C7 12'A" C2 17� 34 C7 22 C5 14'-7" 31 C7 1-0 8 xz 14-0 31 120 B 12 D 18 C2 14 4 30 C7 10-7" t7 C1 70'-T' 29 C7 10 9" 20 Cl 10' 4" 28 17-7' 28 Z9 72_1 yp 15� �' C7 10 120 C 17'$ 27 21 7V.4• 30 C9 ty-Ir 20 7➢-#" 29 1V8 77 108 C7 C2 C7 23 CS 1 32 C7 73'-1D" 23 iSa 3� 120C 17'�" C2 9-71Y' 39 C9 701" 77 C1 10•^7" C7 10'}S^ 2E1 C1 gam` 1Z-0" 2g W-7' 3D 14� 14-1" 32 C7 18� 20 13'� C7 11' 120C 17 Il-r 21 21 9 7P 30 1D-0 2D g �' 29 29 9'�• 1a 20 C7 #1'-9^ 19 C2 11 $" 31 C7 14-7 2D x3 C5 13'�" 32 GS 13'-3" Y3 C5 72 5' 32 12DB 1 C2 98" 30 Ca 9'-S is 93 C7 B� 21 C2 8_g• 30 11'6' 22 11'-7" 31 13-18 17 ranc 70 S q$ 34 7, 21 3 x8 x 0.042 BEAM W/ Bi4 12 GA STL INSERT DBL 3 x 8 x 0.042 W/ B1" DBL 14 GA STL INSERT 6i8 DBL 12 GASTL INSERT DBL 12 GA STL INSERT ,y + .. _ a, ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING TRIB W ID i1-f WIND E)P. MAX POST SPACING (SPAN) FTG. ON.) S I" B 2`2-C' 18 12 20 S 120 B 2D.E. i8 12D C 20'-C 21 7 12A H 79-2' 19 120 C iB=10 21 6 s2D s sa-u' 19 120 C 77 8 22 9, 720 B 1T-0" 79 120 C 1B�" 18-1" 22 2D 10' 1209 120 C IT -It' 23 11' 2-1 B M-4' 20 120 C 15.2" 23 rIT,129 B 74'-9" 20 120 C #4W 23 MIN. TYPE MAX POST FTG. MIN. MAX POST FIG. MIN. MAX POST FTG. MIN. SE MAX POST FTG. MIN POST MAX POST FTG POST SPACING (IN.) T°pE SPACING ON) TYPE SPACING ON.) SPACING (IN) TYP> SPACING (SPAN) (INJ TYPE (SPAN) (SPAN) (SPAN) (SPAN) Cl 2Z-8- 33 CB 28-2' 19 C2 29-2 35 C9 3F-0' 20 CS 32-0 29'-2• C11 35 c9 "J7 32 c7 �.$" 20 2s.$' 35 c9 z0•�' 2n cz � � 25-3" 35 C77 28'-Z 23 Z7'$ C71 19�" 1°-2 34 32 CB 26-3' C7 24'-8 23 24'�" 34 CB 2T1" 21 C5 27'-r' 35 C9 C2 CS 25 8 37 C11 CS 18-2' 33 CB 24'_4" 23 IT-F 3S C9 T 1' 24 78�' 31 CT 23'-S 21 C5 23'•T 33 CB iS3' 21 CS 25'T 34 C2 17'-1" 33 C8-9 24 22 0' 35 09 2S 3 25 24' ' 23-10" 39 C11 35 17-0 C7 21'-1d' 21 C5 2 34 C9 23=10" 22 C5 C9 35 'IF-T, 1- 5y" 32 32 24 21 200Ar 20_g 3d 34 C9 23-1C" 2Z4" 25 22 Z2'�f 22 C5 21'� 35 C5 C7 2O'-Er' 2D'-0 C5 CS C5 35 25 79-8' 34 28 22-1" 15•-3" 15-' 32 32 CT 19'-G' 22 CS 19 $' 35 Z1. �" 27' 71 C5 Z1 C9 3S I,C 7' 32 CS IV-6' 25 1B 3" 34 21' $' 28 B" 28 T3 21'•#" 20'$ CS 36 C11 CS 14' S' ... 9 33 TrT C8 o a 22 x CS 794r la W 35 34 C9 20$' 28 CS ZD' 2' 35 C9 NOTES: t - WHEN THE PATIO COVER IS INSTALLED ON A SLAB ON GRADE (RESIDENTIALAPFUCA71ONS ONLY), THE MAAMUM POST SPACING 13 THE LOWEST OF THE "MAX POST SPACING (SPAN' SHOWN ABOVE AND THE MA)OML;M POST SPACINGS SHOWN ON DETAIL 8fL7-1 2.- 7 Z ACCEPTABLE TO SUBTIT[ITE COLUMNS WI HIGHER NUMBERS WI THOSE SPECIFIED IN THE TABLES SHOWN. ATTACHED & FREESTANDING LATTICE COVERS -10 PSF SNOW LOAD OR LIVE LOAD -130 MPH - E XP, i & C 3"SQ. ALUM W/ B9 DBL2x6.5x0.042 B1] 3x8x0.042 B5 12GASTL"U"CHANNEL 610 DBL2x6.5x0.032 B12 DBL3x8x0.042 B13 xO.042 VW ATTACHED FREESTANDINCs ATTACHEb FREESTANL}NG ATTRCHE❑ ���JJJ 14GASTLINSERT FREESTANDING ATTACHED FREESTANDING ATTACHEp FREESTANDING ATTACHED FREESTANDING MAX MIN. MAX MIN. MAX MIN MAX MIN MAX MIN. MAX MIN. MAX MAX MAX TRIB WIND POST i fG. POST POST FTG. POST POST FTG. POST POST FTG. POST FTG. POST FTG. POST FTG. MIN. POST FTC. MOST POST FTG. MIN. POSOST FTG. MAX MAX POST FIG. POST POST FTG. P031 W DTH EXP, MAX SPACING (IN) TYPE SPACING (IN.) TYPE SPACING (IN.) TYPE SPACING OR) POST SPACING N POST POST POST MIN.MIN. MIN. (SPAN) (SPAN) POST (SPAN) (SPAN) iYPt (SPAN) )TYPE SPACING (IN.) TYPE SPACING (IN.) TYPE (SPANG (IN.) TYPE SPACING ON.) TYPE SPACING (SPAN) QN.) TYPE (PACING (IN.) TYPE SPACING (IN) TYPE 5 1300 1t79" 17 Cl 14-7" 32 co 14�17 tg Cl 14'-10" 31 C7 ig�" 1g (SPAN) i5'•2' 3T 18-0 17 M (SPAN) 130 C #5�7 19 14 7" 34 C10 14'�^ 79 13=8" 33 14=10' 19 C1 C7 C1 1T$" 33 G7 2t'8 19 21''I" 34 CS 2D'-0 16 2D-0" 32 C8 s 13013 15'•3" 18 Cl 13'�' 31 C9 TT-7` 17 T3=7' 91 Id_1^ 14 ' 17'•3 20 16$' 31 C6 20'-10" 21 Ct C1 C1 C7 17 C7 13'-10" 31 16� 18 2D-0" 36 C11 20�I' 23 19-1" 34 G9 130C i3.9 I 13-3" 34 CIO 73'-1' T8 12'W 32 13'7' 19 i8'-0' 32 C7 C1 18-2' 3Z C7 1B=6' 19 19'•7" 33 CB 19'-0 19 CI 18'-S, 32 C8 7 130 B 14-2 58 C1 12'�^ 97 Ce T2 7" 17 C1 12'--7' 30 C7 13=7" 77 T2-10 30 iv-1Lr 20 15-1" 33 G8 79-!" 22 18'�" 35 C9 T8'.3" 21 G2 17 B 33 C9 130C 12'� 20 12-0" 33 C10 12'-2 20 1T=7' 31 12_T• 20 C1 C7 15'2' T8 C1 P5-v 31 C7 16�" 20 1B'•1" 33 tT_T' v is 13'•3' 19 C1 11-7" 30 C8 7f'-9' 18 11-9' 29 C7 12�„ 19 12 7 31 14$ 2T 14'-0" 33 -8 17 8 22 C8 13 C2 17'3" 3S C7 12.1" 29 14'-3" 19 C7 14'-1" 31 77. 16-10" 34 T7 0 22 161 33 CS 1309 11-10" 20 11'-7^ 32 CIO 11'�" 20 1D'-TO" 31 i1 9 20 C7 1T'-3 31 C7 C7 2' 20 1T-0 32 C7 15�' 20 T8'2 30 C7 9 130 B 12 T 19 C1 11-0 30 CD 11'� 19 Cl 1T-2 2a C7 11-7 T6 11,y 29 T3'-9' 21 C2 13'-1' 32 1$-7^ 75-10" 34 CB 1S"7t?' 130 G 11'"3' 21 11-0" 3x CB 10.9' 21 10'-s' 30 11 �" 21 C1 10 6' 30 C7 13 $' 19 C2 13;g 30 C7 15,�„ 21 16 T 32 C9 18-0 32 C7 15 20 15; 1308 12 0 19 C2 10'-0" 90 CS 10'-7 18 10'-7' Zg f3'� 22 12� 37 75$" CS C2 3" 3i C7 10' 10 9 29 15-0" 33 CB 15 0" 23 14'' 3" 32 co 130G 10 $" 2f Cl tp 4" 32 C7 10-Z 21 Cl S 30 C7 10 T, 2� C7 y_IO" 30 C7 12.9 20 C2 12-T' 30 C7 i5'�" 2T 15.2 37 G7 14'-9' 2f 14 B' 31 130E 71'4 18 9-}0 30 CB 70.T^ 19 TO'-1' 29 12'� �2 11-9 3# 14'-10 24 CS CS C7 11' C2 i0S' 18 14'�" 39 C8 14 2 23 13.7" 31 130 C I0'q" ZZ 9'-10" 32 C9 e. C7 C7 C7 1a�,. C7 72' 2' 20 17-0" 31 1d 8 2t T4 32 C8 14'-1" 2f is-10` 32 07 9' 2T 3'3" 31 H=10" 27 A'-0 37 11'•9 23 C2 C7 CS 7309 10-10 20 9 fi 31 C8 9'�" 19 9'8' 29-To- -t1'-3. 31 14'•Z 24 13'•i' 32 C7 18-7" 24 C' 13-0 3f C8 12' 13D C g=9 22 C2 9 5 33 010 9'�" 22 9'-0' 3T C7 9' C2 ° 4 20 C7 f 1'•t� C2 T7 37 14'-t" 22 13'-10 32 8'-3" 31 11'-3" 23 70'9 3T C7 13'•7 24 C' CB TS'S' 27 13'�" 32 OTES: 1 - WHEN THE PATIO COVER IS INSTALLED ON A SLAB ON GRADE (RESIDENTALAPPLICAT)ONS ONLY), THE MAAMUM POST SPACING IS THE LOWEST OF THE "MAX POSTSPACING (SPAN)' SHOWN ABOVE AND THE MAXIM UM POST SPACINGS SHOWN ON DETAIL WL7.1 2 -IT IS ACC;PTABLE TO SUBTFWTE COLUMNS WI HIGHER NUMBERS W/ THOSE SPECIFIED IN THE TABLES SHOWN. 49725 DUSTI ROSEEINK �FS 5885 rp DO L 51970 , y%Iko iIu I IIli III,, D� CONNcj •,r,�J ,4 N0.32875 N .2 877 = �QNA u. 5 �T� OF CAL1� s10NAl E ►rfrlrrl lr111►j1�',, '+/+f lf1/111100 ARIZONA LICENSE CALIFORNIA LICENSE COLORADO LICENSE CONNECTICUT LICENSE DELAWARE LICENSE 1Q�1 I. �Cn'G ��,�p�5,•.. �.]� +r 'J'hlNi d' -:0 ` .r LICENSED <11 ~ PROFESSIONAL 16508 J 'DUSTIN R06Ff'INK;'° p ► 081.0074N ENGINEER r No. 15 87 �� - OF ,�Q [ 0f rtN ROSEe ""+Irn11111111411i��� 1 - HAWAII LICENSE IDAHO LICENSE ILLINOIS LICENSE tiµsr u u r`ri,,�/+/ ��u lu I I I I I ill,►► `�t�► of 1r "'�i t� OF &fA O� h4 ! a y rG,fFrrr 00 �P �L to ON" ��Q ;G � a� DUSTIN K DUSTIN K. -Z ' y: ROSEPINK "' = ROSEPINK CIVIL = 2 No. 6201065154 ❑.53 78 '''•%p�,IDNAL��'.�` '�r,// �I r11111►►'''�� MARYLANDrLICENSE MASSACHUSETTS LICENSE MICHIGAN LICENSE •:•_— o'�E551p�''�ir. DUSTIN K. Uzl: ROSEPINK r r 9 ___E,41: •�lrrrnls►ti,. IOWA LICENSE ```slrrrrrr/i ,t K RO y1+ti,,1, 1111r1r+r+!/!r .Q NS - 20550 z, •.ur -r u c. r '�,!//r�+1NA 1-1114``t` KANSAS LICENSE ENGINEER �1 55517 S ci OF M110 op miss ff+lrlrtiss ��iy►,rRl�f 10 MINNESOTA LICENSE MISSISSIPPI LICENSE ,tjllil II1111I t�rir K ' Rps� 001111 MI/jr11 CAR �, p,O?ESS/O � 4p NEW �iq �{C �+1,p ✓/�I `� S A ti�,,�gN ❑ �C5 1 '' • a DUSTIN -�\ s� - �� �{G31 MSC ¢ ROSEPINK z DUSTIN K. �0 C x = _ � cn - PE 19228 v, ROSEPINK m 204 U = 035378 - m fn ' No.15 02 - 1 _ SGf��4�?; � O /ONAL E,,,�' ,N � �S '� aye. RTH DPI �IIJIIIIf11111 NEW HAMPSHIRE LICENSE NEW MEXICO LICENSE NORTH CAROLINA LICENSE NORTH DAKOTA LICENSE DUSTIN ROSEPINK 123841 A E I TEXAS LICENSE gT RUCco TU�q! ,y w No.9466229-2203 tL Oac DUSTIN ROSEPIN UTAH LICENSE Q USM K. ROSEPINK Lic. No. 040205B543 � 'd �a 0 o� VIRGINIA LICENSE L ASHINGTON LICEN ? GEN��E'���: 84040 rll +Ilf1111114115•�� FLORIDA LICENSE •°����,,c�C� KEN •r�f''�''- ..........T� DUSTIN K. * ROSEPINK 32350 TONAL •E`;�t`'��� •f �11114Iplrr I I11 m 4uOO'N KENTUCKY LICENSE OF MIS P ` rbG ~ DUSTIN �i 1eosErl:;t` , PE-201502503� ��; h �Z/ oN.aL �tP!PISTNo. PE042590 f10FESSI0NA GEORGIA LICENSE •►� 0 OFi `.wg4t� M��'. DUSTIN K * FIOSEPINK =b PE1 � NAB ►►�` MAINE LICENSE rr' DUSTIN K. ROSEPINK I E-16923 MISSOURI LICENSE NEBRASKA LICENSE ��►y�p PROFE �`co �NC,VNI=tir�i 61971PE 7- 3ON k �11V7K'.'RO.54, OREGON LICENSE .,esq, ra l Jt < ', PE 15352��r_ YC. J�OS,f "11I'1'Y0 M1N�' WYOMING LICENSE K. ROSEPINK PE087174 ENGINEER PENNSYLVANIA LICENSE HGTE PROFESSIONAL VAMPS ARE SHOWNY/ITYOUT THE UGEhSE EXPIRATION DATE. PLEASE CHECK WITH THE STATE►YIleRE THE PRD]EGT 1S BUILT OR CALL GST'cL MINEERING FOR C1IRREIdf UCE45E EXPIRATION DATE.