BRES2019-017978-495 CALLE TAMPICO D VOICE (760) 777-7125
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011
DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 6/12/2019
Permit Type/Subtype: BUILDING RESIDENTIAL/REMODEL Owner:
Application Number: BRES2019-0179 ROBERT FOSTER
Property Address: 53569 VIA PISA 30 SAVONA WALK
APN: 777190006 � LONG BEACH, CA 92253
Application Description: FOSTER / ADD FIREPLACE & R DOO�� D
Property Zoning:
Application Valuation: $22,500.00
JUN 12 2019
Applicant: Contractor:
1LC CUSTOM HOME IMPROVEMENT AND REMODELI CITY OF LA QUINTA JLC CUSTOM HOME IMPROVEMENT AND REMODELI
42215 WASHINGTON STREET DESIGN & DEVELOPMENT DEPARTMENT 42215 WASHINGTON STREET
SUITE A354 SUITE A354
PALM DESERT, CA 92211 PALM DESERT, CA 92211
(760)464-5676
Llc. No.: 1009256
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 {commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: B License No.: 1009256
Date: W Contractor: (W I
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
() I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) 1, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
oftk for which this permit is issued.
kl-I'have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: MID-CENTURY INSURANCE COMPANY Policy Number: BNUWC0147044
certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
complywiththose provisions. �(
Date: [L' 2 )G Applicant: `
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE 15 UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above -mentioned property for inspection purposes. L,
Date:% Signature (Applicant or Agent): ����
Date: 6/12/2019
Application Number:
BRES2019-0179
Property Address:
53569 VIA PISA
APN:
777190006
Application Description
FOSTER / ADD FIREPLACE & FRENCH DOOR
Property Zoning:
Application Valuation:
$22,500.00
Applicant:
JLC CUSTOM HOME IMPROVEMENT AND REMODEU
42215 WASHINGTON STREET
SUITE A354
PALM DESERT, CA 92211
Owner:
ROBERT FOSTER
30 SAVONA WALK
LONG BEACH, CA 92253
Contractor:
JLC CUSTOM HOME IMPROVEMENT AND REMODELI
42215 WASHINGTON STREET
SUITE A354
PALM DESERT, CA 92211
(760)464-5676
Llc. No.: 1009256
Detail: INSTALLATION OF FRENCH DOORS AND NEW FIREPLACE AT MASTER BEDROOM AREA (CHARLES GARLAND ENGINEERING]. 2016 CALIFORNIA
BUILDING CODES.
DESCRIPTION
ACCOUNT CITY AMOUNT
BSAS SB1473 FETE
101-0000-20306 0 $1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES, FIRST 20
101-0000-42403
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES, FIRST 20 PC
101-0000-42600
0
$26.68
Total Paid for ELECTRICAL: $53.36
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PLAN CHECK DEPOSIT - ADDITION/REMODEL
101-0000-42600
1
$125.00
Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $125.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RECORDS MANAGEMENT FEE - MAJOR
101-0000-42416
0
$21.00
Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
REMODEL, FIRST 100 SF
101-0000-42400
0
$54.43
DESCRIPTION
ACCOUNT
CITY
AMOUNT
REMODEL, FIRST 500 SF PC
101-0000-42600
0
$148.89
Total Paid for REMODEL: $203.32
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SMI - RESIDENTIAL
101-0000-20308
0
$2.93
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $2.93
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($18.27)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($106.73)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DOOR/WINDOW, NEW/ALT, FIRST 1
101-0000-42400
0
$106.73
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DOOR/WINDOW, NEW/ALT, FIRST 1 PC
101-0000-42600
0
$103.40
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DOOR/WINDOW, NEW/ALT, FIRST 1 PC
101-0000-42600
0
$18.27
Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: $103.40
W
Project Address:
APN #:
Applicant Name: cetsi M ""o
Address:`
City, ST, Zip:
Telephone:
Email: Joy (J)JLGCuS �Un-, � CoP717
Property Owner's Name:
Address:
City, ST, Zip CZ-r cw �f a
Telephone: - a So - r.
Email • 1e
PERMIT #
S Project Description:
C- C
(-)( Fv' .
Valuation of Project $
No
New Commercial / Tenant Improvements:
Total Building SE
Construction Type: Occupancy:
V,Jto `1-1 hG ICA 0"d L U F-n 1
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
ki
vir I 01-picv�*->39 8
OFFICE USE ONLY
# Submittal
vian Sets
Structural Calcs
Required Received
Truss Calcs
Title 24 Calcs
Soils Report
Grading Plan (PM10)
Landscape Plan
Subcontractor List
Grant Deed
HOA Approval
School Fees
Burrtec Debris Plan
Planning approval
Public Works approval
Fire approval
City Business License
BUILDING ENERGY ANALYSIS REPORT
-2.619
S3-576q VlA ply
PROJECT:
FOSTER RESIDENCE's alteration
53569 VIA PISA
LA QUINTA, CA 92253
Project Designer:
GLS ARCHITECTURE GROUP INC.
74991 JONI DR #9
PALM DESERT, CA 92260
760 340.3528
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
DATE ly
Report Prepared by:
Armando Chavez
44890 SEELEY
LA QUINTA, CA 92253
760 278.1840
Job Number:
19-GLS/025 -041
Date:
5/17/2019
RECEIVED
MAY 302019
CITY OF LA QUINTA
DESIGN AND DEVELOPMENT DEPARTMENT
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards.
This program developed by EnergySoft Software — www.energysoft.com.
1 TABLE OF CONTENTS I
Cover Page 1
Table of Contents 2
Form CF-1 R-PRF-01-E Certificate of Compliance 3
Form RMS-1 Residential Measures Summary 10
Form MF-1 R Mandatory Measures Summary 11
HVAC System Heating and Cooling Loads Summary 15
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: FOSTER RESIDENCE Calculation Date/Time: 15:25, Fri, May 17, 2019
Calculation Description: Title 24 Analysis Input File Name: 041 - 53569 VIA PISA.ribd16x
CF1 R-PRF-01
Page 1 of 7
GENERAL
INFORMATION
01
Project Name
FOSTER RESIDENCE
02
Calculation Description
Title 24 Analysis
03
Project Location
53569 VIA PISA
04
City
LA QUINTA 05 Standards Version Compliance 2017
06
Zip Code
92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149)
08
Climate Zone
CZ15 09 Software Version CBECC-Res 2016.3.1 (1019)
10
Building Type
Single Family 11 Front Orientation (deg/Cardinal) 90
12
Project Scope
Addition and/or Alteration 13 Number of Dwelling Units 1
14
Total Cond. Floor Area (ft2)
4361 15 Number of Zones 1
16
Slab Area (ft)
4361 17 Number of Stories 1
18
Addition Cond. Floor Area (ft2)
0 19 Natural Gas Available Yes
20
Addition Slab Area (ft)
0 21 Glazing Percentage (%) 15.4%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building DOES NOT require HERS Verification
03 This building incorporates one or more Special Features shown below
04
Energy Use (kTDV/ft2-yr)
Space Heating
05
Standard Design
3.45
ENERGY USE SUMMARY
06
Proposed Design
3.54
07
Compliance Margin
-0.09
08
Percent Improvement
-2 6%
Space Cooling
195.99
195.09
0.90
0.5%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water Heating
6.18
6.18
0.00
0.0%
Photovoltaic Offset
----
0.00
0.00
----
Compliance Energy Total
205.62
204.81
0.81
0.4%
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-05-17 15:25:47
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1 R-PRF-01
Project Name: FOSTER RESIDENCE
Calculation Description: Title 24 Analysis
HERS FEATURE SUMMARY
Calculation Date/Time: 15:25, Fri, May 17, 2019
Input File Name: 041 - 53569 VIA PISA.ribdl6x
Page 2 of 7
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• --None--
Cooling System Verifications:
• -- None --
HVAC Distribution System Verifications:
• -- None --
Domestic Hot Water System Verifications:
• -- None --
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
FOSTER RESIDENCE
4361
1
3
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
(E) 4361
Conditioned
(E) AC-1
4361
8
DHW Sys 1
n/a
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
10
11
Name
Zone
Construction
Azimuth
Orientation
Gross Area
(ft)
Window & Door
Area (ft2)
Tilt
(deg)
Wall
Exception
Status
Verified
Existing
Condition
N - 476
(E) 4361
Def Wall '92 to Present
0
Right
476
35.25
90
n/a
Existing
No
E - 437
(E) 4361
Def Wall '92 to Present
90
Front
437
116
90
n/a
Existing
No
S - 159
(E) 4361
Def Wall '92 to Present
180
Left
159
24
90
n/a
Existing
No
SW - 625
(E) 4361
Def Wall '92 to Present
225
135
625
173.246
90
n/a
Existing
No
NW - 755
(E) 4361
Def Wall '92 to Present
315
225
755
33725
90
n/a
Existing
No
SE- 120
(E) 4361
Def Wall '92 to Present
135
45
120
11.4525
90
n/a
Existing
No
4361
(E) 4361
Def Roof '78 to Present
4361
n/a
Existing
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-05-17 15:25:47
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: FOSTER RESIDENCE Calculation Date/Time: 15:25, Fri, May 17, 2019
CF1 R-PRF-01
Page 3 of 7
Calculation Description: Title 24 Analysis
Input File Name: 041 - 53569 VIA PISA.ribd16x
ATTIC
01
02
03
04
05
06
07
08
09
10
Name
Construction
Type
Roof Rise
Roof
Reflectance
Roof
Emittance
Radiant
Barrier
Cool
Roof
Status
Verified Existing
Condition
Attic (E) 4361
Attic Roof(E) 4361
Ventilated
4
0.1
0.85
No
No
Existing
No
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multiplier
Area (ft2)
U-factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
2646
N - 476 (Right-0)
2.5
4.5
1
11.3
0.71
0.73
Insect Screen (default)
Existing
No
2020
N - 476 (Right-0)
2.0
2.0
1
4.0
0.71
0.73
Insect Screen (default)
Existing
No
2050
N - 476 (Right-0)
2.0
5.0
1
10.0
0.71
0.73
Insect Screen (default)
Existing
No
20502
N - 476 (Right-0)
2.0
5.0
1
10.0
0.71
0.73
Insect Screen (default)
Existing
No
5080
E - 437 (Front-90)
5.0
8.0
1
40.0
0.71
0.73
Insect Screen (default)
Existing
No
50802
E - 437 (Front-90)
5.0
8.0
1
40.0
0.71
0.73
Insect Screen (default)
Existing
No
4090
E - 437 (Front-90)
4.0
9.0
1
36.0
0.71
0.73
Insect Screen (default)
Existing
No
2656
SW - 625 (- specify --225)
2.5
5.6
0.982
13.7
0.71
0.73
Insect Screen (default)
Existing
No
26562
SW - 625 (- specify --225)
2.5
5.6
0.982
13.7
0.71
0.73
Insect Screen (default)
Existing
No
26563
SW - 625 (- specify 7-225)
2.5
5.5
1
13.8
0.71
0.73
Insect Screen (default)
Existing
No
8090
SW - 625 (- specify --225)
8.0
9.0
1
72.0
0.71
0.73
Insect Screen (default)
Existing
No
60100
SW - 625 (- specify --225)
6.0
10.0
1
60.0
0.71
0.73
Insect Screen (default)
Existing
No
26564
NW - 755 (- specify --315)
2.5
5.5
1
13.8
0.71
0.73
Insect Screen (default)
Existing
No
26565
NW - 755 (- specify --315)
2.5
5.5
1
13.8
0.71
0.73
Insect Screen (default)
Existing
No
26566
NW - 755 (- specify --315)
2.5
5.5
1
13.8
0.71
0.73
Insect Screen (default)
Existing
No
80902
NW - 755 (- specify --315)
8.0
9.0
1
72.0
0.71
0.73
Insect Screen (default)
Existing
No
601002
NW - 755 (- specify --315)
6.0
10.0
1
60.0
0.71
0.73
Insect Screen (default)
Existing
No
12090
NW - 755 (- specify --315)
12.0
9.0
1
108.0
0.71
0.73
Insect Screen (default)
Existing
No
7080
NW - 755 (- specify --315)
7.0
8.0
1
56.0
0.51
0.24
Insect Screen (default)
Altered
n/a
26462
SE- 120 (- specify --135)
2.5
4.5
1.018
11.5
0.71
0.73
Insect Screen (default)
Existing
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-05-17 15:25:47
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: FOSTER RESIDENCE Calculation Date/Time: 15:25, Fri, May 17, 2019
CF1 R-PRF-01
Page 4 of 7
Calculation Description: Title 24 Analysis
Input File Name: 041 - 53569 VIA PISA.ribd16x
OPAQUE DOORS
01
02
03
04
05
06
Name
Side of Building
Area (ft2)
U-factor
Status
Verified Existing Condition
3080
S - 159
24.0
0.50
Existing
No
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
2646
2
0.1
2
2
0
0
0
0
0
0
0
0
0
2020
2
0.1
2
2
0
0
0
0
0
0
0
0
0
2050
2
0.1
2
2
0
0
0
0
0
0
0
0
0
20502
2
0.1
2
2
0
0
0
0
0
0
0
0
0
5080
2
0.1
2
2
0
0
0
0
0
0
0
0
0
50802
2
0.1
2
2
0
0
0
0
0
0
0
0
0
4090
2
0.1
2
2
0
0
0
0
0
0
0
0
0
2656
2
0.1
2
2
0
0
0
0
0
0
0
0
0
26562
2
0.1
2
2
0
0
0
0
0
0
0
0
0
26563
2
0.1
2
2
0
0
0
0
0
0
0
0
0
8090
2
0.1
2
2
0
0
0
0
0
0
0
0
0
60100
2
0.1
2
2
0
0
0
0
0
0
0
0
0
26564
2
0.1
2
2
0
0
0
0
0
0
0
0
0
26565
2
0.1
2
2
0
0
0
0
0
0
0
0
0
26566
2
0.1
2
2
0
0
0
0
0
0
0
0
0
80902
2
0.1
2
2
0
0
0
0
0
0
0
0
0
601002
2
0.1
2
2
0
0
0
0
0
0
0
0
0
12090
2
0.1
2
2
0
0
0
0
0
0
0
0
0
7080
2
0.1
2
2
0
0
0
0
0
0
0
0
0
26462
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-05-17 15:25:47
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: FOSTER RESIDENCE Calculation Date/Time: 15:25, Fri, May 17, 2019 Page 5 of 7
Calculation Description: Title 24 Analysis
Input File Name: 041 - 53569 VIA PISA.ribd16x
OPAQUE SURFACE CONSTRUCTIONS
01 02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name Surface Type
Construction Type
Framing
R-value
U-factor
Assembly Layers
• Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roof(E) 4361 Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
Inside Finish: Gypsum Board
Cavity / Frame: R-13 / 2x4
Def Wall '92 to Present Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.101
Exterior Finish: 3 Coat Stucco
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
Def Roof'78 to Present attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
Rig
0.049
Over Ceiling Joists: R-9.9 insul.
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ft2)
Perimeter
(ft)
Edge Insul. R-value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
4361 2
(E) 4361
4361
0.1
None
0.8
No
Existing
No
BUILDING ENVELOPE - HERS VERIFICATION
01
Quality Insulation Installation (QII)
02
Quality Installation of Spray Foam Insulation
03
Building Envelope Air Leakage
04
CFM50
Not Required
Not Required
Not Required
n/a
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
N
Status
Verified Existing
Condition
DHW Sys 1
DHW
Standard
DHW Heater 1
1
0
Existing
No
Registration Number: Registration DatelTime: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-05-17 15:25:47
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: FOSTER RESIDENCE
Calculation Description: Title 24 Analysis
Calculation Date/Time: 15:25, Fri, May 17, 2019
Input File Name: 041 - 53569 VIA PISA.ribdl6x
CF1 R-PRF-01
Page 6 of 7
WATER HEATERS
01 02 03
04 05 06 07 08 09
10
11
12
Input Rating / Tank Standby
Heater
Tank Uniform Energy Pilot / Insulation Loss I
First Hour
Tank Location
Element
Number Volume Factor / Energy Thermal R-value Recovery
Rating /
NEEA Heat Pump
or Ambient
Name Type Tank Type
of Units (gal) Factor / Efficiency Efficiency (Int/Ext) Eff
Flow Rate
Brand / Model
Condition
DHW Heater 1 Gas Small Storage
1 50 0.525 EF <= 75 kBtu/hr 0 n/a
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01 02
03 04 05
06
07
08
Distribution
Verified Existing
SC Sys Name System Type
Heating Unit Name Cooling Unit Name Fan Name
Name
Status
Condition
(E) AC-1 Other Heating and Cooling Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution
System 1
Existing
No
System
HVAC - DISTRIBUTION SYSTEMS
01 02
03 04 05 06 07
08
09
10
Insulation Supply Duct Return Duct
Verified Existing
HERS
Name Type
Duct Leakage R-value Location Location Bypass Duct
Status
Condition
Verification
Ducts located in attic
Air Distribution (Ventilated and
Existing (not 6.0 Attic Attic None
Existing
No
n/a
System 1 Unventilated)
specified)
IAQ (Indoor Air Quality) FANS
01
02 03 04
05
06
IAQ Recovery
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type
Effectiveness(%) HERS Verification
SFam IAQVentRpt
0 0.25 Default
0
Not Required
PROJECT NOTES
-- ALL EXISTING AND PROPOSED INPUT DATA USED IN THIS REPORT WAS PROVIDED BY THE PLANS PREPARER. -- LOAD CALCULATIONS AND AC SIZING EQUIPMENT SHALL BE
VERIFIED BY THE AC CONTRACTIOR PRIOR TO PLACEMENT OF ITS ORDER. -- AC EQUIPMENT'S EFFICENCY SHALL BE EQUAL (OR BETTER) THAN REQUIRED BY THIS REPORT. --
ANY ALTERATION OR DEVIATION FROM THIS REPORT WILL BE GENERAL CONTRACTOR'S RESPONSABILITY.
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-05-17 15:25:47
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: FOSTER RESIDENCE Calculation Date/Time: 15:22, Fri, May 17, 2019 Page 7 of 7
Calculation Description: Title 24 Analysis Input File Name: 041 - 53569 VIA PISA.ribd16x
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name: Documentation Author Signature:
Armando Chavez
Company: Signature Date:
5/17/2019
Address. CEA/HERS Certification Identification (If applicable):
44890 SEELEY
City/StateRbU I NTA, CA 92253 Phone: 760 278.1840
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Dees�ner Name: Responsible Designer Signature:
Company: t�IIVV Date Signed.
GLS ARCHITECTURE GROUP INC.
Address: License:
74991 JONI DR #9
City/State?zi : Phone:
PI,LM DESERT, CA 92260 760 340.3528
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2019-05-17 15:23:16
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
FOSTER RESIDENCE'S alteration
Project Address
53569 VIA PISA LA QUINTA
Building Type 2 Single Family ❑ Addition Alone
❑ Multi Family 10 Existing+ Addition/Alteration
Date
511712019
California Energy Climate Zone Total Cond. Floor Area Addition
CA Climate Zone 15 4,361 0
# of Units
1
INSULATION
Construction Type
Area
Cavity (e) Special Features
Status
Wall Wood Framed R 13 1,875
Door Opaque Door no insulation 24
Slab Unheated Slab -on -Grade - no insulation 4,361 Perim = 0'
Existing
Existing
Existing
Roof Wood Framed Attic R 19 4,361
Existing
FENESTRATION Total Area: 673 Glazin Percents e: 15.4°� N,,JAltered Average U-Factor.
Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades
0.51
Status
Right (N) 35.3 0.710
0.73 2.0 none Bug Screen
Existing
Front (E) 116.0 0.710
0.73 2.0 none Bug Screen
Existing
Left (SW) 173.3 0.710
0.73 2.0 none Bug Screen
Existing
Rear (NW) 281.3 0.710
0.73 2.0 none Bug Screen
Existing
Rear (NW) 56.0 0.510
0.24 2.0 none Bug Screen
Altered
Front (SE) 11.5 0.710
0.73 2.0 none Bug Screen
Existing
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff Thermostat
Status
1 Central Furnace 78% AFUE
HVAC DISTRIBUTION
Location Heating
Split Air Conditioner 9.7 SEER Setback
Duct
Cooling Duct Location R-Value
Existing
Status
(E) AC- Ducted Ducted Attic 6.0
WATER HEATING
Qty. Type Gallons Min. Eff Distribution
Existing
Status
EnerqyPro 7.1 by EnergySoft User Number: 20648
ID: 19 - GLS / 025 - 041
Paqe 10 of 15
cill r�
2016 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. *Exceptions may apply.
in inai uurzu-i 1, i
Building Envelope Measures:
Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ftz or less when tested per
§ 110.6(a)1:
NFRC-400 or ASTM E283 or AAMAIWDMA/CSA 101/I.S.2/A440-2011.'
§ 110.6(a)5:
Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a).
Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES
§ 110.6(b):
110.6-A and 110.6-B for compliance and must be caulked and/or weatherstri ed.'
Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
§ 110.7:
asketed, or weather stripped.
§ 110.8(a):
Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material.
§ 110.8(g):
Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g).
§ 110.8(i):
Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing
material must meet the requirements of § 11 0.8i when the installation of a cool roof is specified on the CF1 R.
§ 110.80):
Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043.
Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
§ 150.0(a):
insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited
to placing insulation either above or below the roof deck or on top of a drywall ceiling.*
§ 150.0(b):
Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value.
Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-factor of 0.074 or
§ 150.0(c):
less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a
wood framed assembly.*
§ 150.0(d):
Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.'
§ 150.0(f):
Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light
deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 11 0.8.
Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This
§ 150.0(g)1:
requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 150.0(d).
Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all
§ 150.0(g)2:
insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation.
150.0
§ (q)'
Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.'
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 150.0(e)1A:
Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)l B:
Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area
and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.'
§ 150.0(e)1 C:
Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control:
§ 150.0(e)2:
Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of
the building, are prohibited.
Space Conditioning, Water Heating, and Plumbing System Measures:
§ 110.0-§ 110.3:
Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
appliances must be certified by the manufacturer to the Energy Commission.`
§ 110.2(a):
HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.'
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§ 110.2(b):
must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for
compression heafingis higher than the cut-off temperature for supplementary heating.'
§ 110.2(c):
Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat.'
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
§ 110.3(c)5:
meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of §
110.3(c)5.
§ 110.3(c)7:
Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs
or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed.
Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli-
§ 110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt); and pool and spa heaters!
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment
§ 150.0(h)1-
Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA
Manual J using design conditions specified in § 150.0(h)2.
2016 Low -Rise Residential Mandatory Measures Summary
§ 15Q.0(h)3A:
Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any
dryer vent.
§ 150.0(h)3B:
Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by
manufacturer's instructions.
§ 150.00)1:
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must
be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a
§ 150.00)2A:
nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter;
piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to
kitchen fixtures.'
§ 150.00)2B:
Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof
and non -crushable casing or sleeve!
§ 150.00)2C:
Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution
piping for steam and h dronic heating systems or hot water s stems must meet the requirements in TABLE 120.3-A.`
§ 150.00)3:
Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by
§ 150.00)3A:
aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can
cause degradation of the material.
§ 150.00)3B:
Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a
Class I or Class II vapor retarder.
Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a
§ 150.0(n)1:
120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside
termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr.
§ 150.0(n)2:
Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification
Corporation (SRCC) or by a listiq agency that is approved by the Executive Director.
Ducts and Fans Measures:
§ 110.8(d)3:
Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a
contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement.
CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC
§§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or
a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing
§ 150.0(m)1
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than'/. inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain
ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts.'
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
§ 150.0(m)2:
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such tape is used in combination with mastic and draw bands.
§ 150.0(m)3:
Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
mastics, sealants, and other requirements specified for duct construction.
§ 150.0(m)7:
Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
automatic dampers.
§ 150.0(m)8:
Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
§ 150.0(m)9:
wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation.
§ 150.0(m)10:
Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)11:
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 150.0(m)11 and Reference Residential Appendix RA3.
Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,
pressure drop, and labeling requirements of § 150.0(m)12.
R
2016 Low -Rise Residential Mandatory Measures Summary
Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable
space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the
supply plenum. The space conditioning system must also demonstrate airflow z 350 CFM per ton of nominal cooling capacity through the return
§ 150.0(m)13:
grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central
forced airs stems.'
Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor
§150.0(o):
continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of
providing whole -building ventilation.
Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic
§ 150.0(o)1A:
testing, in accordance with Reference Residential Appendix RA3.7.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater
§ 110.4(a):
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heating.'
Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated
§ 110.4(b)1:
suction and return lines, or built-in or built-up connections to allow for future solar heating.
§ 110.4(b)2:
Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
§ 110.4(b)3:
will allow all pumps to be set or programmed to run only during off-peak electric demand periods.
§ 110.5:
Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
150.0
§ (p)'
rate, piping, filters, and valves.'
Lighting Measures:
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
§ 110.9:
of § 110.9.'
JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must
§ 110.9(e):
be certified to the Energy Commission according to Reference Joint Appendix JA8.
§ 150.0(k)1A:
Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or
§ 150.0(k)1 B:
other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fan speed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)1 C:
labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C. A JA8-2016-E light source rated for
elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings.
§ 150.0(k)1 D:
Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than
20 kHz.
Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no
§ 150.0(k)1 E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled
by, vacancy sensors.
§ 150.0(k)1 F:
Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
must meet the applicable requirements of § 150.0(k).'
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply
§ 150.0(k)1 G:
with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix
JA8.'
§ 150.0(k)1 H:
Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E."
§ 150.0(k)2A:
Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B:
Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.'
§ 150.0(k)2C:
Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually
switched ON and OFF.
§ 150.0(k)2D:
Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with
150.0(k).
§ 150.0(k)2F:
Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it:
§ 150.0(k)2G:
functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of §
130.5(f); and meets all other requirements in § 150.0(k)2
Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the
§ 150.0(k)2H:
following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of §
130.5 ; and all other requirements in § 150.0(k)2.
§ 150.0(k)21:
Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
2016 Low -Rise Residential Mandatory Measures Summary
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
§ 15Q.0(k)2J:
be controlled by a vacancy sensor
Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with
§ 150.0(k)2K:
Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.'
§ 150.0(k)2L:
Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A:
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item
§ 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3A11i (photo control and automatic time switch control, astronomical time clock, or
EMCS).
Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies,
§ 150.0(k)3R
and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with
either § 150.0(k)3A or with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by
§ 150.0(k)3C:
150.0 k 3B or § 150.0(k)3D must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more
§ 150.0(k)3D:
vehicles per site must complywith the applicable requirements in 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
§ 150.0(k)4:
power as determined according to § 130.0(c).
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
§ 150.0(k)5:
applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1,130.4, 140.6, and 141.0.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A:
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be high efficacy luminaires and controlled by an occupant sensor.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must:
§ 150.0(k)6B:
i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent. The occu part sensors must be capable of turnip g the right ful ly on and off from all d esig ned p aths of i rig ress and eg Tess.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1:
application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the
requirements of § 110.10(b) through § 110.10 e .
§ 110.10(a)2:
Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d).
Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local
jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet
each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas
§ 110.10(b)1:
greater than 10,000 square feet.
For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250
square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang
of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less
than 15 percent of the total roof area of the building excluding any skylight area.'
§ 110.10(b)2:
Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.'
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)3B.
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone, measured in the vertical lane.`
§ 110.10(b)4
Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof
dead load and roof live load must be clearly indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for
§ 110.10(c):
routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system.
§ 110.10(d):
Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
110.1 0c must be provided to the occupant.
§ "0'10(e)1:
Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2:
breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or
main circuit location; and permanently marked as "For Future Solar Electric".
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Date
FOSTER RESIDENCE's alteration
5/17/2019
System Name
Floor Area
(E) AC-
4,361
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
COOLING PEAK
COIL HTG.
PEAK
Heating System
CFM
Total Room Loads 3,848
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation F 0
Supply Fan
Supply Air Ducts
Sensible
Latent
CFM
Sensible
Output per System
80,000
73,714
1,590
1,274
43,798
Total Output (Btuh
80,000
0
Output (Btuh/sgft)
18.3
5,030
2,526
Cooling System
0
0
Output per S stem
1
0
0
0
Total Output (Btuh)
1
0
0
Total Output (Tons)
0.0
5,030
2,526
Total Output (Btuh/sgft)
0.0
TOTAL SYSTEM LOAD
1,590
Total Output s ft/Ton
52,332,000.0
F 83,775
48,851
Air System
CFM per System
0
HVAC EQUIPMENT SELECTION
Airflow (cfm)
0
1992 - 2005 Fau/AC
1
0
80,000
Airflow cfm/sgft
0.00
80,000
Jan 1 AM
Airflow (cfm/Ton)
0.0
Outside Air (%)
0•0%
Total Adjusted System Output 1
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
0
Aug 3 PM
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI
conditions
HEATING SYSTEM PSYCHROMETRICS
(Airstream Temperatures at Time of Heating Peak)
26 IF
67 IF
Outside Air
0 cfm
Heating Coil
100 °F
ROOM
67 IF
68 OF
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak
112/73OF
77/62OF 55/54OF
Outside Air
0 cfm
Cooling Coil
57/55OF
46.6% ROOM
77 / 62 OF
75 ; 62 OF
EnergyPro 7.1 by EnergySoft
User Number: 20648 ID: 19 - GLS / 025 - 041 Page 15 of 15