BRES2019-015978-495 CALLE TAMPICO T-itit UVOICE (760) 777-7125
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 6/4/2019
Permit Type/Subtype: BUILDING RESIDENTIAL/REMODEL Owner:
Application Number: BRES2019-0159 PAMELA HIMEL
Property Address: 80575 VIA TERRACINA 71 GLEN EDYTH DR
APN: 777260009 TORONTO ON CANADA M4V, V8 92253
Application Description: HIMEL/ REMODEL- WINDOW/DOOR CHANGES+ RELOCATE BAR SINK
Property Zoning:
Application Valuation: $50,000.00
Applicant: ❑ Contractor:
WHITLEY'S CONSTRUCTION CORPORATION WHITLEY'S CONSTRUCTION CORPORATION
77-775 JACKAL DRIVE SUITE B F
77-775 JACKAL DRIVE SUITE B
PALM DESERT, CA 92211 JU1J 0 4 2019 PALM DESERT, CA 92211
CITY OF LACUINTA (760)341-9480
DESIGN & DEVELOPMENT DEPARTMENT Llc. No.: 805021
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 {commencing with Section 70001 of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: B License No.: 805021 r� r
i� �
Dat�=k Cdntractor:
r
OWNER -BUILDER DECLARATION f
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
() I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Add
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of t w rk for which this permit is issued. ,
lyhave and will maintain workers' compensation insurance, as required by
Se ion 3 00 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: BENCHMARK INSURANCE COMPANY • Policy Number: CST5015957
I certify that in the performance of the work for which this permit is issued, 1
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
>7afe. Applicant: n
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVE�GE WFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above -mentioned property for inspection purposes.
Date: Signature (Applicant or Agent):
Date: 6/4/2019
Application Number:
BRES2019-0159
Owner:
Property Address:
80575 VIA TERRACINA
PAMELA HIMEL
APN:
777260009
71 GLEN EDYTH DR
Application Description
HIMEL/ REMODEL- WINDOW/DOOR CHANGES+ RELOCATE BAR SINK
TORONTO ON CANADA M4V, V8 92253
Property Zoning:
Application Valuation:
$50,000.00
Applicant:
Contractor:
WHITLEY'S CONSTRUCTION CORPORATION
WHITLEY'S CONSTRUCTION CORPORATION
77-775 JACKAL DRIVE SUITE B
77-775 JACKAL DRIVE SUITE B
PALM DESERT, CA 92211
PALM DESERT, CA 92211
(760)341-9480
Llc. No.: 805021
Detail: HIMEL/ REMODEL AT REAR OF DWELLING. REMOVE POST TO ENLARGE WINDOW OPENINGS, REMOVE WINDOW & INSTALL DOOR+ RELOCATE BAR
SINK. 2016 CALIFORNIA BUILDING CODES.
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT
CITY
AMOUNT
101-0000-42600
($2.00)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
BSAS SB1473 FEE
101-0000-20306
0
$2.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $0.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PLAN CHECK DEPOSIT - ADDITION/REMODEL
101-0000-42600
1
$125.00
Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $125.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($13.34)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($13.34)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FIXTURE/TRAP
101-0000-42401
0
$13.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FIXTURE/TRAP PC
101-0000-42600
0
$13.34
Total Paid for PLUMBING FEES: $0.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($10.00)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RECORDS MANAGEMENT FEE
101-0000-42416
0
$10.00
Total Paid for RECORDS MANAGEMENT FEE: $0.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($0.50)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SMI - RESIDENTIAL
101-0000-20308
0
$0.50
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
101-0000-42600
($5.00)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $0.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($80.82)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DOOR/WINDOW, NEW/ALT, EA ADDITION 1
101-0000-42400
0
$22.42
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DOOR/WINDOW, NEW/ALT, EA ADDITION 1 PC
101-0000-42600
0
$25.72
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DOOR/WINDOW, NEW/ALT, FIRST 1
101-0000-42400
0
$106.73
DESCRIPTION I ACCOUNT I CITY
AMOUNT
DOOR/WINDOW, NEW/ALT, FIRST 1 PC 101-0000-42600 0 $40.85
DESCRIPTION ACCOUNT CITY AMOUNT
DOOR/WINDOW, NEW/ALT, FIRST 1 PC 101-0000-42600 0 $80.82
Total Paid for WINDOW/SLIDING GLASS DOOR/FENESTRATION: $195.72
PERMIT # 01,�q
P1 AN LOCATION:
Project Address: vS�s'�r� (e� �a Project Description:z
Applicant Name: �e-
Ad d ress:
City, ST, Zip:
Telephone:
Email: Valuation of Project 5 S6, ood
Property Owner's Name: ( S
_ C r Wtc�
Address: is
0VtkTcl-rici t
City, ST, Zip (a7
Telephone:
Email
New Commercial / Tenant Improvements:
Total Building SF
Construction Type: Occupancy:
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
OFFICE USE ONLY
i
# Submittal Required Received
Plan Sets
Structural Calcs
Truss Calcs
i
Title 24 Calcs
Soils Report
Grading Plan (PM10)
Landscape Plan
Subcontractor List
Grant Deed
HOA Approval
School Fees
Burrtec Debris Plan
Planning approval
Public Works approval
Fire approval
City Business License
Construction
77-775 Jackal Drive Suite B Palm Desert, Ca. 92211
Office 760-341-9480 Fax 760-341-9481
Lie. # 805021
City of La Quinta
78495 Calle Tampico
La Quinta, CA. 92253
To whom it may concern,
Please note Bobby Mignogna is authorized to submit plans, pick up plans and permits
on behalf of Whitley's Construction Corp.
Thank yo TJ
-A
Jason Whitley
Whitley's Construction Corp.
760-341-9480
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
HIMEL S.F.R. alteration
80575 VIA TERRACINA
LA QUINTA, CA 92253
Project Designer:
GLS ARCHITECTURE GROUP INC.
74991 JONI DR #9
PALM DESERT, CA 92260
760 340.3528
RECEIVED
MAY 17 2019
CITY OF LA QUINTA
DESIGN AND DEVELOPMENT DEPARTMENT
Report Prepared by:
Armando Chavez
44890 SEELEY
LA QUINTA, CA 92253 BRES?•ot1- OI 549
760 278.1840 CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
DATE r] BY JF
Job Number:
19 - GLS / 016 - 034
Date:
5/3/2019
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards.
This program developed by EnergySoft Software — www.energysoft.com.
0
I TABLE OF CONTENTS I
Cover Page
Table of Contents
Form CF-1 R-PRF-01-E Certificate of Compliance
Form RMS-1 Residential Measures Summary
Form MF-1 R Mandatory Measures Summary
2
3
10
11
I EnergyPro 7.1 by EnergySoft Jnh Nurnhnr- ID: 19 - GLS 1016 - 034 User Number: 20648 1
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: HIMEL S.F.R. Calculation Date/Time: 11:31, Fri, May 03, 2019
CFI R-PRF-01
Page 1 of 7
Calculation Description: Title 24 Analysis
Input File Name: 035 - 041 - 80575 VIA TERRACINA.ribd16x
GENERAL INFORMATION
01
Project Name
HIMEL S.F.R.
02
Calculation Description
Title 24 Analysis
03
Project Location
80575 VIA TERRACINA
04
City
LA QUINTA
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.3.1 (1149)
08
Climate Zone
CZ15
09
Software Version
CBECC-Res 2016.3.1 (1019)
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
90
12
Project Scope
Addition and/or Alteration
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ftZ)
1732
15
Number of Zones
1
16
Slab Area (ftZ)
1732
17
Number of Stories
1
18
Addition Cond. Floor Area (ftZ)
0
19
Natural Gas Available
Yes
20
Addition Slab Area (ftZ)
0
21
Glazing Percentage (%)
25.8%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building DOES NOT require HERS Verification
03
This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ftZ-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
17.36
18.72
-1.36
-7.8%
Space Cooling
444.74
419.99
24.75
5.6%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water Heating
15.32
15.32
0.00
0.0%
Photovoltaic Offset
----
0.00
0.00
----
Compliance Energy Total
477.42
454.03
23.39
4.9%
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-05-03 11:32:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: HIMEL S.F.R.
Calculation Description: Title 24 Analysis
HERS FEATURE SUMMARY
Calculation Date/Time: 11:31, Fri, May 03, 2019
Input File Name: 035 - 041 - 80575 VIA TERRACINA.ribd16x
CF1 R-PRF-01
Page 2 of 7
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• --None--
Cooling System Verifications:
• --None --
HVAC Distribution System Verifications:
• --None --
Domestic Hot Water System Verifications:
- ..None --
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ftZ)
Number of Dwelling
Units.
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
HIMEL S.F.R.
1732
1
3
1
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
(E) 1732
Conditioned
AC-1
1732
9
DHW Sys 1
n/a
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
10
11
Name
Zone
Construction
Azimuth
Orientation
Gross Area
(ftZ)
Window & Door
Area (ft)
Tilt
(deg)
Wall
Exception
Status
Verified
Existing
Condition
N - 282
(E) 1732
Def Wall '92 to Present
0
Right
282
53
90
n/a
Existing
No
E - 995
(E) 1732
Def Wall Prior to '78
90
Front
995
74
90
n/a
Existing
No
S - 536
(E) 1732
Def Wall Prior to '78
180
Left
536
225
90
n/a
Existing
No
W - 1025
(E) 1732
Def Wall Prior to '78
270
Back
1025
122
90
n/a
Existing
No
TO GARAGE
(E) 1732
Def Wall Priorto'781
320
0
n/a
Existing
No
1732
(E) 1732
Def Roof'78 to Present
1732
n/a
Existing
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-05-03 11:32:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: HIMEL S.F.R. Calculation Date/Time: 11:31, Fri, May 03, 2019
CF1 R-PRF-01
Page 3 of 7
Calculation Description: Title 24 Analysis
Input File Name: 035 - 041 - 80575 VIA TERRACINA.ribd16x
ATTIC
01
02
03
04
05
06
07
08
09
10
Name
Construction
Type
Roof Rise
Roof
Reflectance
Roof
Emittance
Radiant
Barrier
Cool
Roof
Status
Verified Existing
Condition
Attic (E) 1732
Attic Roof(E) 1732
Ventilated
4
0.1
0.85
No
No
Existing
No
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multiplier
Area (ft2)
U-factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
5050
N - 282 (Right-0)
5.0
5.0
1
25.0
0.71
0.60
Insect Screen (default)
Existing
No
4040
E - 995 (Front-90)
4.0
4.0
1
16.0
0.71
0.60
Insect Screen (default)
Existing
No
40402
E - 995 (Front-90)
4.0
4.0
1
16.0
0.71
0.60
Insect Screen (default)
Existing
No
3040
E - 995 (Front-90)
3.0
4.0
1
12.0
0.71
0.73
Insect Screen (default)
Existing
No
1640
E - 995 (Front-90)
1.5
4.0
1
6.0
0.71
0.73
Insect Screen (default)
Existing
No
16402
E - 995 (Front-90)
1.5
4.0
1
6.0
0.71
0.73
Insect Screen (default)
Existing
No
16403
E - 995 (Front-90)
1.5
4.0
1
6.0
0.71
0.73
Insect Screen (default)
Existing
No
30402
E - 995 (Front-90)
3.0
4.0
1
12.0
0.71
0.73
Insect Screen (default)
Existing
No
8050
S - 536 (Left-180)
8.0
5.0
1
40.0
0.71
0.73
Insect Screen (default)
Existing
No
13016
S - 536 (Left-180)
13.0
1.5
1
19.5
0.51
0.24
Insect Screen (default)
New
n/a
13080
S - 536 (Left-180)
13.0
8.0
1
104.0
0.51
0.24
Insect Screen (default)
New
n/a
3080
S - 536 (Left-180)
3.0
8.0
1
24.0
0.51
0.24
Insect Screen (default)
New
n/a
3016
S - 536 (Left-180)
3.0
1.5
1
4.5
0.51
0.24
Insect Screen (default)
New
n/a
30802
S - 536 (Left-180)
3.0
8.0
1
24.0
0.51
0.24
Insect Screen (default)
New
n/a
6016
S - 536 (Left-180)
6.0
1.5
1
9.0
0.51
0.24
Insect Screen (default)
New
n/a
40403
W - 1025 (Back-270)
4.0
4.0
1
16.0
0.71
0.60
Insect Screen (default)
Existing
No
6040
W - 1025 (Back-270)
6.0
4.0
1
24.0
0.71
0.60
Insect Screen (default)
Existing
No
2040
W - 1025 (Back-270)
2.0
4.0
1
8.0
0.71
0.60
Insect Screen (default)
Existing
No
20402
W - 1025 (Back-270)
2.0
4.0
1
8.0
0.71
0.60
Insect Screen (default)
Existing
No
60402
W - 1025 (Back-270)
6.0
4.0
1
24.0
0.71
0.60
Insect Screen (default)
Existing
No
5040
W - 1025 (Back-270)
5.0
4.0
1
20.0
0.71
0.60
Insect Screen (default)
Existing
No
2640
W - 1025 (Back-270)
4.0
4.0
0.625
10.0
0.71
0.60
Insect Screen (default)
Existing
No
30403
W - 1025 (Back-270)
4.0
4.0
0.75
12.0
0.71
0.60
Insect Screen (default)
Existing
No
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149
HERS Provider:
Report Generated at: 2019-05-03 11:32:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: HIMEL S.F.R. Calculation Date/Time: 11:31, Fri, May 03, 2019
CF1 R-PRF-01
Page 4 of 7
Calculation Description: Title 24 Analysis
Input File Name: 035 - 041 - 80575 VIA TERRACINA.ribd16x
OPAQUE DOORS
01
02
03
04
05
06
Name
Side of Building
Area (ft2)
U-factor
Status
Verified Existing Condition
3680
N - 282
28.0
0.50
Existing
No
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09 10
11 12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
5050
2
0.1
2
2
0
0
0
0
0
0
0
0
0
4040
2
0.1
2
2
0
0
0
0
0
0
0
0
0
40402
2
0.1
2
2
0
0
0
0
0
0
0
0
0
3040
2
0.1
2
2
0
0
0
0
0
0
0
0
0
1640
2
0.1
2
2
0
0
0
0
0
0
0
0
0
16402
2
0.1
2
2
0
0
0
0
0
0
0
0
0
16403
2
0.1
2
2
0
0
0
0
0
0
0
0
0
30402
13
0.1
13
13
0
0
0
0
0
0
0
0
0
8050
2
0.1
2
2
0
0
0
0
0
0
0
0
0
13016
13
0.1
13
13
0
0
0
0
0
0
0
0
0
13080
13
0.1
13
13
0
0
0
0
0
0
0
0
0
3080
13
0.1
13
13
0
0
0
0
0
0
0
0
0
3016
13
0.1
13
13
0
0
0
0
0
0
0
0
0
30802
2
0.1
2
2
0
0
0
0
0
0
0
0
0
6016
2
0.1
2
2
0
0
0
0
0
0
0
0
0
40403
2
0.1
2
2
0
0
0
0
0
0
0
0
0
6040
2
0.1
2
2
0
0
0
0
0
0
0
0
0
2040
2
0.1
2
2
0
0
0
0
0
0
0
0
0
20402
2
0.1
2
2
0
0
0
0
0
0
0
0
0
60402
2
0.1
2
2
0
0
0
0
0
0
0
0
0
5040
2
0.1
2
2
0
0
0
0
0
0
0
0
0
2640
2
0.1
2
2
0
0
0
0
0
0
0
0
0
30403
2
0.1
2
2
0
0
0
0
0
0
0
0
0
Registration Number: Registration DatelTime: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-05-03 11:32:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: HIMEL S.F.R.
Calculation Description: Title 24 Analysis
Calculation Date/Time: 11:31, Fri, May 03, 2019
Input File Name: 035 - 041 - 80575 VIA TERRACINA.ribd16x
CF1 R-PRF-01
Page 5 of 7
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-factor
Assembly Layers
Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roof(E) 1732
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
Def Roof '78 to Present
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 19
0.049
Over Ceiling Joists: R-9.9 insul.
• Inside Finish: Gypsum Board
• Cavity/Frame: R-13/2x4
Def Wall '92 to Present
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.101
Exterior Finish: 3 Coat Stucco
• Inside Finish: Gypsum Board
• Cavity/Frame: no insul. /2x4
Def Wall Prior to '78
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
none
0.361
Exterior Finish: 3 Coat Stucco
Inside Finish: Gypsum Board
• Cavity/Frame: no insul. /2x4
Def Wall Prior to '781
Interior Walls
I Wood Framed Wall
2x4 @ 16 in. O.C.
none
0.277
Other Side Finish: Gypsum Board
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ft)
Perimeter
(ft)
Edge Insul. R-value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
17322
(E) 1732
1732
0.1
None
0.8
No
Existing
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Not Required
Not Required
Not Required
n/a
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
N
Status
Verified Existing
Condition
DHW Sys 1
DHW
Standard
DHW Heater 1
1
0
Existing
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-05-03 11:32:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: HIMEL S.F.R. Calculation Date/Time: 11:31, Fri, May 03, 2019 Page 6 of 7
Calculation Description: Title 24 Analysis
Input File Name: 035 - 041 - 80575 VIA TERRACINA.ribd16x
WATER HEATERS
01
02
03 04
05
06
07
08
09
10
11
12
Input Rating I
Tank
Standby
Heater
Tank
Uniform Energy
Pilot /
Insulation
Loss /
First Hour
Tank Location
Element
Number
Volume
Factor / Energy
Thermal
R-value
Recovery
Rating /
NEEA Heat Pump
or Ambient
Name
Type
Tank Type of Units
(gal)
Factor / Efficiency
Efficiency
(Int/Ext)
Eff
Flow Rate
Brand / Model
Condition
DHW Heater 1
Gas
Small Storage
1
50
0.525 EF
<= 75 kBtu/hr
0
n/a
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
Distribution
Verified Existing
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Name
Status
Condition
AC-1
Other Heating and Cooling
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution
System 1
Existing
No
System
I
I
I
I
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R-value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
(Ventilated and
Existing (not
2.1
Attic
Attic
None
Existing
No
n/a
System 1
Unventilated)
specified)
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
0
0.25
Default
0
Not Required
PROJECT NOTES
-- ALL EXISTING AND PROPOSED INPUT DATA USED IN THIS REPORT WAS PROVIDED BY THE PLANS PREPARER. -- LOAD CALCULATIONS AND AC SIZING EQUIPMENT SHALL BE
VERIFIED BY THE AC CONTRACTIOR PRIOR TO PLACEMENT OF ITS ORDER. -- AC EQUIPMENT'S EFFICENCY SHALL BE EQUAL (OR BETTER) THAN REQUIRED BY THIS REPORT. --
ANY ALTERATION OR DEVIATION FROM THIS REPORT WILL BE GENERAL CONTRACTOR'S RESPONSABILITY.
Registration Number: Registration DatefFime: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-05-03 11:32:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1 R-PRF-01
Project Name: HIMEL S.F.R.
Calculation Description: Title 24 Analysis
Calculation Date/Time: 11:26, Fri, May 03, 2019
Input File Name: 035 - 041 - 80575 VIA TERRACINA.ribd 1 6x
Page 7 of 7
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Armando Chavez
Signature Date:
Company:
5/3/2019
Address:
CEA/HERS Certification Identification (If applicable):
44890 SEELEY
City/StatVX:OUINTA, CA 92253
Phone: 760 278.1840
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible De si ner Name:
PU'' ROMERO
Responsible Designer Signature:
Company:
Date Signed:
GLS ARCHITECTURE GROUP INC.
Address:
74991 JONI DR #9
License:
City/State/Zi :
�XLM DESERT, CA 92260
Phone:
760 340.3528
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2019-05-03 11:27:10
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
HIMEL S.F.R. alteration
Project Address
80575 VIA TERRACINA LA QUINTA
Building Type M Single Family ❑ Addition Alone
❑ Multi Family [Z Existing+Addition/Alteration
California Energy Climate Zone Total Cond. Floor Area Addition
CA Climate Zone 15 1,732 0
Date
51312019
# of Units
1
INSULATION
Construction Type
Cavity
Area
(ft) Special Features
Status
Roof Wood Framed Attic
Slab Unheated Slab -on -Grade
R 19
- no insulation
1,732
1,732 Perim = 0'
Existing
Existing
Wall Wood Framed
Door Opaque Door
R 13
- no insulation
229
28
Existing
Existing
Wall Wood Framed
- no insulation
2,455
Existing
FENESTRATION
Orientation Area ft2)
I Total Area: 446 Glazin Percenta e: 25.8% New/Altered Average U-Factor:
U-Fac SHGC Overhang Sidefins Exterior Shades
0.51
Status
Right (N) 25.0
0.710
0.60 2.0
none Bug Screen
Existing
Front (E) 32.0
Front (E) 30.0
0.710
0.710
0.60 2.0
0.73 2.0
none Bug Screen
none Bug Screen
Existing
Existing
Front (E) 12.0
0.710
0.73 13.0
none Bug Screen
Existing
Left (S) 40.0
0.710
0.73 2.0
none Bug Screen
Existing
Left (S) 152.0
0.510
0.24 13.0
none Bug Screen
New
Left (S) 33.0
0.510
0.24 2.0
none Bug Screen
New
Rear (M 122.0
0.710
0.60 2.0
none Bug Screen
Existing
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling
Min. Eff Thermostat
Status
1 Central Furnace
78% AFUE
Split Air Conditioner 9.7 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Cooling
Duct
Duct Location R-Value
Status
AC- Ducted
Ducted
Attic 2.1
Existing
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution
Status
EnrayPro 7.1 by EnerjqySoft User Number: 20648
ID: 19 - GLS / 016 - 034
Paqe 10 of 14
2016 Low -Rise Residential Mandatory Measures Summary
'NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. *Exceptions may apply.
(Original 08/2016)
Building Envelope Measures:
§ 110.6(a)1:
Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft' or less when tested per
NFRC-400 or ASTM E283 or AAMAIWDMA/CSA 101/I.S.2/A440-2011.'
§ 110.6(a)5:
Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a).
§ 110.6(b):
Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES
I I0.6-A and 110.6-B for compliance and must be caulked and/or weatherstri ed.'
§ 110.7:
Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
asketed, or weather stripped.
§ 110.8(a):
Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material.
§ 110.8(g):
Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g).
§ 110.8(i):
Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing
material must meet the requirements of § 110.8 i when the installation of a cool roof is specified on the CF1 R.
§ 110.80):
Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043.
Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
§ 150.0(a):
insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited
to placing insulation either above or below the roof deck or on top of a drywall ceiling.*
§ 150.0(b):
Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value.
Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-factor of 0.074 or
§ 150.0(c):
less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a
wood framed assembly.'
§ 150.0(d):
Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.'
§ 150.0 ft
Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light
deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 11 0.8.
Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This
§ 150.0(g)1;
requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 150.0(d).
Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all
§ 150.0(g)2:
insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation.
150.0
§ (q)'
Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
maximum U-factor of 0.58: or the weighted average U-factor of all fenestration must not exceed 0.58.'
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 150.0(e)lA:
Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)l B:
Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area
and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.'
§ 150.0(e)1 C:
Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.'
§ 150.0(e)2:
Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of
the buildin , are prohibited.
Space Conditioning, Water Heating, and Plumbing System Measures:
§ 110.0-§ 110.3:
Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
appliances must be certified by the manufacturer to the Energy Commission.'
§ 110.2(a):
HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K:
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§ 110.2(b):
must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for
compression heating is higher than the cut-off temperature for supplementary heating.*
§ 110.2(c):
Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat.'
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
§ 110.3(c)5:
meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of §
11 0.3c 5.
§ 110.3(c)7:
Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs
or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed.
§ 110.5:
Pilot Lights. Continuously buming pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli-
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt); and pool and spa heaters.'
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment
§ 150.0(h)l:
Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA
Manual J using design conditions specified in § 150.0(h)2.
Z,:-
x 2016 Low -Rise Residential Mandatory_Measures Summary
f 150.0(h)3A:
Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any
dry er vent.
§ 150.0(h)3B:
Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by
manufacturer's instructions.
§ 150.06)1.
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must
be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a
§ 150.00)2A:
nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter;
piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to
kitchen fixtures.'
§ 150.00)2B:
Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof
and non -crushable casin or sleeve.'
§ 150.00)2C:
Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution
pi2ing for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.'
§ 150.06)3:
Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by
§ 150.06)3A:
aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can
cause degradation of the material.
§ 150.06)3B:
Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a
Class I or Class II vapor retarder.
Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a
§ 150.0(n)l
120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside
termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the
water heater, and allows natural draining without pump assistance; and a gas suppl line with a capacity of at least 200,000 Btu/hr.
§ 150.0(n)2:
Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification
Corporation (SRCC) or by a listingagency that is approved by the Executive Director.
Ducts and Fans Measures:
§ 110.8(d)3:
Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a
contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement.
CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC
§§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or
a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing
§ 150.0(m)1:
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than % inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain
ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts.'
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
§ 150.0(m)2:
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such tape is used in combination with mastic and draw bands.
§ 150.0(m)3:
Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
mastics, sealants, and other requirements specified for duct construction.
§ 150.0(m)7:
Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
automatic dampers.
§ 150.0(m)8:
Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
§ 150.0(m)9:
wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation.
§ 150.0(m)10:
Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)l 1.
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 150.0(m)l land Reference Residential Appendix RA3.
Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,
pressure drop, and labeling requirements of § 150.0(m)12.
r
2016 Low -Rise Residential Mandatory Measures Summary
Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable
'
space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the
§ 150.0(m)13:
supply plenum. The space conditioning system must also demonstrate airflow z 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy _< 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central
forced airs stems.'
Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor
§150.0(o):
continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of
providing whole -building ventilation.
§ 150.0(o)lA:
Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.7.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
§ 110.4(a):
that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heating.*
§ 110.4(b)1:
Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated
suction and return lines, or built-in or built-up connections to allow for future solar heating.
§ 110.4(b)2:
Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b)3:
Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
will allow all pumps to be set or programmed to run only during off-peak electric demand periods.
§ 110.5:
Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
§ 150.0 (p):
Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
rate,. i in , filters, and valves.'
Lighting Measures:
§ 110.9:
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
of § 110.9.'
§ 110.9(e):
JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must
be certified to the Energy Commission according to Reference Joint Appendix JA8.
§ 150.0(k)lA:
Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or
§ 150.0(k)l B:
other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fan speed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)l C:
labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)l C. A JA8-2016-E light source rated for
elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings.
§ 150.0(k)l D:
Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than
20 kHz.
Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no
§ 150.0(k)l E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled
by vacancv sensors.
§ 150.0(k)1 F:
Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
must meet the applicable requirements of § 150.0(k).'
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply
§ 150.0(k)l G:
with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix
JA8.`
§ 150.0(k)1H:
Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E."
§ 150.0(k)2A:
Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B:
Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.'
§ 150.0(k)2C:
Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually
switched ON and OFF.
§ 150.0(k)2D:
Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with
150.0(k).
§ 150.0(k)2F:
Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it:
§ 150.0(k)2G:
functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of §
130.5 , and meets all other requirements in § 150.0(k)2.
Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the
§ 150.0(k)2H:
following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of §
130.5 _ ; and all other requirements in § 150.0(k)2.
§ 150.0(k)21:
Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
provides the functionality of a dimmer according to.§ 110.9, and complies with all other applicable requirements in § 150.0(k)2.
r -
2016 Low -Rise Residential Mandatory Measures Summary
150.0(k)2J:
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
be controlled by a vacancy sensor.
Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with
§ 150.0(k)2K:
Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallwa s.'
§ 150.0(k)2L:
Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A:
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item
§ 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or
EMCS).
Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies,
§ 150.0(k)3B:
and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with
either § 150.0(k)3A or with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)3C:
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by
§ 150.0(k)3B or § 150.0(k)3D must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)3D:
Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more
vehicles per site must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0.
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 wafts of
§ 150.0(k)4:
power as determined according to § 130.0(c).
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
§ 150.0(k)5:
applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1, 130.4, 140.6 and 141.0.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A:
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be high efficacy luminaires and controlled by an occupant sensor.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must:
§ 150.0(k)6B:
i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1:
application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the
requirements of § 110.10(b) through § 110.10(e).
§ 110.10(a)2:
Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d).
Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local
jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet
each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas
§ 110.10(b)1
greater than 10,000 square feet.
For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250
square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang
of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less
than 15 percent of the total roof area of the building excluding any skylight area.'
§ 110.10(b)2:
Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.'
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)3B.
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone, measured in the vertical plane.'
§ 110.10(b)4:
Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof
dead load and roof live load must be clearly indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for
§ 110.10(c):
routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system.
§ 110.10(d):
Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
110.10 c must be provided to the occupant.
§ 110.10(e)1:
Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2:
breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or
main circuit location; and permanently marked as "For Future Solar Electric".