11-0405 (AR)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 11-00000.04.0.5 Property Address: 55632 OAK TREE APN: 775 -231 -009 - Application description: ADDITION - RESIDENTIAL, Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 35000 Tay/ " BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Architect or Engineer: alo LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury at am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Bus, ess a dProfessionals Code, and my License is in full force and effect. License Class: B License No.: 594043 ate: A ontract.r: • OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjur that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or'she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her, own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or .improve for the purpose of sale.). (_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractorls) licensed pursuant to the Contractors' State License Law.). 1 _ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: A Lender's Address: T LQPERMIT VOICE (760) 777-7012. FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 7/21/11 Owner: VERSHURE RICHARD & MAUREEN 11 HUNTER AVENUE U' ARMONK, NY 10504 D lJ t j 2 r, 2011 JUL Contractor: F Cl�y{pTA 7CIS CONSTRUCTION & MAINT C{�1(Q�. �GP. 48236 VISTA DE NOPAL • f{Lyt!SC'L LA QUINTA, CA 92253 (760)564-5811 Lic. No.: 594043 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of.the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 0026211-2008 _ I certify that, in the AORKERS, of the work for which this permit is issued, I shall not employ any person in any mabecome subject to the workers' compensation laws of California, and agree that, im sub* to the workers' compensation provisions of Section 3700 of the LabII f hw' comply with those provisions. Date: ` tSECURE nt: WARNING: FAIL RE' C PENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnity and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. ' ' 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date.of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify at 1 have read this application and state that the ove i formation is correct. I agree to comply with all city county ordinances a state laws relating to bull ng con ruction, and hereby authorize representatives of �s 1ounty to enter up the above-mentioned prope for i p tion poses. Date: �—!'+I ignature (Applicant or Agent): Application Number . . . 11-00000405 LQPERMIT Structure Information Construction Type TYPE V, UNPROTECTED Occupancy Type . . . . . DWELLG/LODGING/LONG <=10 Other struct info . . . . . CODE EDITION 2010 -------------------------------------------------=----------------- 1ST FLOOR SQUARE FOOTAGE 51.00 --------- Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 317.00 Plan Check Fee 206.05 Issue Date . . . . Valuation 35000 Expiration Date 1/17/12 Qty Unit Charge Per Extension BASE FEE 252.00 10.00 6.5000 -----------------------------------------------------------=---------------- THOU BLDG 25,001-50,000 65.00 Permit . . . ELECT - ADD/ALT/REM Additional desc . . Permit Fee. 43.53 Plan Check. Fee 10.88 Issue Date . . . . Valuation 0 Expiration Date 1%17/12 Qty Unit Charge Per Extension BASE FEE 15.00 35.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 1.23 25.00 .7500 PER ELEC DEVICE/FIXTURE IST 20 18:75 19.00 .4500 ---------------------------------------------------------------------------- EA ELEC DEVICE/FIXTURE >20 8.55 Permit . . MECHANICAL" Additional des& . Permit Fee 24.00• Plan Check Fee 6.00 Issue Date Valuation . . . . 0 Expiration Date 1/17/12 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 4.5000 -------------------------- EA. MECH-VENT INST/ DUCT ALT = --------------------------------------- 9.00 ----------- Permit . . . PLUMBING Additional desc . 'Permit Fee . . . . 27.00 Plan Check Fee 6.75 Issue Date . . . . Valuation . . . . 0 Expiration Date 1/17/12 LQPERMIT .C - Application Number . . . . . 11-00000405 Permit . . . . . . PLUMBING Qty Unit Charge Per Extension BASE FEE 15.00 1.00 6.0000 EA PLB FIXTURE 6.00 1.00 3..0000 EA PLB WATER INST/ALT/REP 3.00 1.00 3.0000 EA PLB FIXTURE DRAIN/VENT REP/ALT 3.00 --------------------------------------------------------------------=------- Special Notes and Comments 51 SF ADDITION & REMODEL TO KITCHEN. PERMIT INCLUDES.LIGHTING, ELECTRICAL, PLUMBING AND MECHANICAL. 2010 CODES. ----------------------------------------------------------------------------- Other -Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 2.00 ENERGY REVIEW FEE 20.61 STRONG MOTION (SMI) -RES 3.50 Fee summary Charged Paid Credited ------------------------------ Due --------------------------- Permit Fee Total 411.53 .00 .00 411.53 Plan Check Total 229.68 .00 .00 229.68 Other Fee Total 26.11 .00 .00 26.11 Grand Total 667.32 .00 .00 667.32 LQPERMIT r Bin # P City of La Quinta Building 8r Safety Division P.O. Box 1504, 78-495 Calle Tampico La Qulnta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit #(o) O Project Address: SS . Z MIFJB Owner's Name: 90 A. P. Number: 7 7 S• ?s3 I • Get - 4 Address: 2 A te- -rge Legal Description: U01—r-17 /(4rTI5 City, ST, Zip: G Contractor:Telephone: �(� 2'ZS ��• � :>::�:;�.;�:.,�.;�:::;�� Address:t►m �� Project Description: City, ST, Zip:(,�y� �1 TGtt�.J Telephone: :: :�:'4'':•E;::.;'.:;•F:.F ��C4r!°s A C7. State Lic. # : City Lic. #; Arch., Engr., Designer: Address: 4<-V ° City., ST, Zip: v��.. cl-z Telephone: 7&b, S`18. . �Q'% ><:: •nJ''' > `r.s; ' '<: Construction Type: Occupancy: State Lic. #: i3 {F:.?>33.'.c<><a k<'s a"E "s Project type (circle one) New Add'n Alter Repair Demo Name of Contact Person: AC�/ Pti Sq. Ft.:rj/ # St ries: #Units: Telephone # of Contact Person: Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for orrecdo Plan Check Deposit Truss Cates. Called Contact Person $ Plan Check Balance. Tide 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted/0 Mechanical Grading plan 2•" Review, ready fo corrections ssue 51^0 Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up d�� S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- ''" Review, ready fo correctlo Issue Developer Impact Fee Planning Approval Called Contact Person I yt ice, Z• A.I.P.P. Pub. Wks. Appr Date of i99ae-irie$46 School FeesL p b J Total Permit Fees . �2 ql zo -q OAS 444cZ s/. . &/a N4&6"411 p &/jAIL7 ate- 4?// 6 JW c 6/�6 Z� 2- *cam•.► -f- t -�. cel • . tic .d `Y L41 �� Oft Coachella Valley Unified. School District .83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVELONEAMOUNT: LEVELTWOAMOUNT: MITIGATION AMOUNT: COMM/IND. AMOUNT: DATE: RECEIPT: CHECK #: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Owner's Name: Richard & Maureen Vershure Project Address: 55-632 Oak Tree, La Quinta, CA 92253 Project Description: Addition to Existing Date: July 21, 2011 Phone No. APN: 775 -231 -009 -----Tract #: Lot #'s: Type of Development: Residential XX Commercial Total Square Feet of Building Area: 51 Certification of Applicant/Owners: The person signing certifies thatn C penalty of perjury and further represents that he/she is authorized to sic Dated: Signature: Industrial information is correct and makes this statement under f of the owner/developer. LD 10-1 SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECV HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Number of Sq.Ft. 51 Amount per Sq.Ft. 0.00 Amount Collected $0.00 Building Permit Application Completed: Yes/No By: Jamie T. Brown, Asst. Supt., Business Services Certificate issued by: Marcela Valdez, Construction Analyst Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a wrl n notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the impo it' of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice hall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or per" ce of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. 1:. IE.(IriiC41 h t , -moi. i0I 11/2010 t.r?Yi � ,, r '.� Mt PGA WEST.. RESIDENTIAL ASSOCIATION, INC. March 4, 2011 Mr. & Mrs. Richard Vershure 55-632 Oak Tree La Quinta, CA 9_2?53 - RE: 55-632 Oak Tree - Enclose Exterior Covered Patio Dear Mr. & Mrs. Vershure, M Page 1 of 2 ne Architecctwal Committee has reviewed your A•chitectu;•ai vaiiauoc rcyuesL. The l.rupust'-d exterior modifications to your unit as shown on drawings dated August 18, 2010, sheets CS, 1-5' and RMA, prepared by Lench Design Studio, Ine. are acceptable. T:ne interior rer vations a,*e not part of our review. The requirement to maintain the existing structural imegrity and compliance .Nith the building code is the homeowner's and their respective architect and engineer. The Homeowner's Association C C&R' the +rdnitem-al Guidelines and the lViaintenance and Indemnity Agreement armyIbis vatiartee. The. follrv. ir_g cor�T ,t� and requirements are applicable; 1. The HOA must be in receipt of contractor's current insurance certificates prior to the start of any work. The certificates are to be provided to the HOA directly from the insurance carrier. As of today, the HOA has not received proof of general liability, workers compensation and auto for 7 C's Construction. 2. Provide a copy of the City of La Quinta building department permit prior to starting any work.- 3. ork.3. Contact the Maintenance Manager, William Aceves, prior to starting any work, to inspect roof area adjacent to the new work. 4. The contractor is not allowed te.stockpile any materia', equipment or construction debris in the streeL 5. The street glitters are not to be used for concrete and constraction.material clean up. The street is to be broom -washed, as needed each day during construction. Neither debris nor dirt is to be washed down the gutter. 6. The street and work area are to be kept clean daily. The contraztor is to observe all Association rules and regulations. S. The centractor to repair andror replace -any damaged irrigation, .landscape, hardseape, lights or street surface to the satisfaction of the HOA. 9. New stucco joints to existing to have proper paper, lathing tie-ins to prevent water intrusion. 10. New paint to be Weathemtaster Vista 1900 or equal hybrid elastomeri: paint. Contact the HOA for }faint color. A1. Confirm the routing of gas supple for the cook top if it is a ;as unit. 54-320 Southern Hills, Le Quinta, California 92253-5665, Telephone 760-771-1234 FAX 760-771-5125 Z -d Page 2 of 2 12. Upon completion, the homeowner is required to provide a signed copy of the city inspection card along with the Notice of Completion form and the Contractor's Notice of Completion Certification letter (enclosed). 13. A reasonable construction time is 90 days. 14. Any work requiring penetration or routing of lines in areas outside of the work area should be noted by the HOA maintenance manager for his information. 15. Prior to the start of any work, the HOA must be in receipt of your contactor' 3 current proof of insurance documents; which are to .be provide .directly from the contractor's insurance carrier(s) and a copy of the contractor's stare license. 16. Mainienance and fndemni1y Agreement to be signed at the beginning and reviewed at the conclusion of the project All applicable'improvements' shall be listed on the agreement and recorded with the County of Riverside. If 1 may be of ftrtlter assistance.—please contact me at the 140A office; (760) 771-134, Extension 15. Cordially oil Kelly McGalliard b Operations Manager For tate Architectural Committee KM-'bvf Enc. 1 cc: Architectural Committee ggd a BUILDING ENERGY ANALYSIS REPORT PROJECT: Vershure Residence 55-632 Oak Tree La Quinta, CA Project Designer: Report Prepared by: Joan D. Hacker Insu-form, Inc. 77-810 Las Montanas Road, Suite 201 Palm Desert, Ca 92211 760-345-1352 r �l APR 1 j 2011 Job Number Date: 4/19/2011 t ,, O tf(GVl CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION )AT [94 � 61 BY laii The EnergyPro computer program has been used to perform the calculations summarized in this compliance eport. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2011-04-19710:44:35 ID: TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 10 HVAC System Heating and Cooling Loads Summary 13 EnergyPro 5.1 by EnergySoR Job Number: ID: User Number: 2655 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Vershure Residence Building Type m Single Family O Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 4/19/2011 Project Address 55-632 Oak Tree La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,8 Addition 51 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status Slab Unheated Slab -on -Grade None 2, 838 Perim = 86' Existing Wall Wood Framed R-13 969 Existing Door Opaque Door None 20 Existing Roof Wood Framed Attic R-22 2,838 Existing Slab Unheated Slab -on -Grade None 51 Perim = 15' New Wall Wood Framed R-13 154 New Roof Wood Framed Attic R-38 51 New FENESTRATION U- Orientation Area Factor Exterior SHGC Overhang Sidefins Shades Status Front (W) 25.0 0.710 0.73 2.0 none Bug Screen Existing Front (W) 20.0 0.710 0.73 2.0 none Bug Screen Existing Front (W) 30.0 0.710 0.73 2.0 none Bug Screen Existing Left (N) 4.0 0.710 0.73 2.0 none Bug Screen Existing Left (N) 35.0 0.710 0.73 2.0 none Bug Screen Existing Left (N) 40.0 0.710 0.73 2.0 none Bug Screen Existing Left (N) 20.0 0.710 0.73 2.0 none Bug Screen Existing Left (N) 20.0 0.710 0.73 2.0 none Bug Screen Existing Rear (E) 21.0 0.710 0.73 2.0 none Bug Screen Existing Rear (E) 4.0 0.710 0.73 2.0 none Bug Screen Existing Rear (E) 15.0 0.710 0.73 2.0 none Bug Screen Existing HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 78% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status Living Zone Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Ot . Type Gallons Min. Eff Distribution Status Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2011-04-19T10:44:35 ID: Pa e 3 of 13 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Vershure Residence Building Type m Single Family O Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 4/19/2011 Project Address 55-632 Oak Tree La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,889 Addition 51 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes IZI No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status FENESTRATION U- Orientation Area Factor Exterior SHGC Overhang Sidefins Shades Status Rear (E) 93.4 0.710 0.73 2.0 none Bug Screen Existing Rear (E) 40.0 0.710 0.73 2.0 none Bug Screen Existing Right (S) 30.0 0.710 0.73 2.0 none Bug Screen New Right (S) 13.5 0.710 0.73 2.0 none Bug Screen Existing Right (S) 10.0 0.710 0.73 2.0 none Bug Screen Existing Rear (E) 53.4 0.710 0.73 2.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ener Pro 5.1 by Ener Soft User Number: 2655 RunCode: 2011-04-19710:44:35 ID: Pa e 4 of 13 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Vershure Residence Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ® Existing+ Addition/Alteration Date 4/19/2011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. EnergyPro 5.1 by Energ ySoft User Number: 2655 RunCode: 2011-0419710:44:35 ID: Page 5 of 13 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date VerShure Residence 1 ❑ Multi Family m Existing+ Addition/Alteration 1411912011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 4.67 3.83 0.85 Space Cooling 124.53 120.09 4.43 Fans 27.02 26.02 1.00 Domestic Hot Water 14.14 14.14 0.00 Pumps 0.00 0.00 0.00 Totals 170.36 164.08 6.28 Percent Better Than Standard: 3.7% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (vv) 270 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (w) 360 75 Fuel Available at Site: Natural Gas (N) 350 119 Raised Floor Area: 0 (E) 522 227 Slab on Grade Area: 2,889 (S) 385 54 Average Ceiling Height: 9.0 Roof 2,889 0 Fenestration Average U -Factor: 0.71 TOTAL: 474 Average SHGC: 0.73 Fenestration/CFA Ratio: 16.4% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Insu-form, Inc. I 4/19/2011 Address 77-810 Las Montanas Road, Suite 201 Name Joan D. Hacker Cit /State/Zip Palm Desert, Ca 92211 Phone 760-345-1352 sisIdy Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company (J50 )cd Address V'D TBS. y� � Named Q�' City/State/Zip ./J ,1"�3j[` Phone 10 igned License# Date (yam Ener Pro 5.1 by Ene Soft User Number.' 2655 RunCode: 2011-04-19T10:44:35 ID: Page 6 of 13 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Vershure Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 1411912011 OPAQUE SURFACE DETAILS Surface Type Area LlInsulation Factor Cavi Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Slab 2,838 0.730 None 0 180 Existing 4.4.7-A1 Existing Living Wall 265 0.102 R-13 270 90 Existing 4.3.1-A3 Existing Living Door 20 1.450 None 270 90 Existing 4.5.1-A1 Existing Living Wall 231 0.102 R-13 0 90 Existing 4.3.1-A3 Existing Living Wall 1771 0.102 R-13 90 90 Existing 4.3.1-A3 Existing Living Wall 297 0.102.R-13 180 90 Existing 4.3.1-A3 Existing Living Roof 2,838 0.043 R-22 270 0 Existing 4.2.1-A6 Existing Living Wall 260 0.102 R-13 90 90 Removec 4.3.1-A3 Existing Living Wall 230 0.102 R-13 180 90 Removec 4.3.1-A3 Existing Living Slab 51 0.730 None 0 180 New 4.4.7-A1 Addition Wall 119 0.102 R-13 90 90 New 4.3.1-A3 Addition Wall 351 0.102 R-13 180 90 New 4.3.1-A3 Addition Roof 511 0.025 R-38 270 0 New 4.2.1-A21 Addition -------------------- FENESTRATION SURFACE DETAILS ID I Type Area Ll -Factor' SHGC2 Azm Status Glazing Type Location/Comments 1 Window 25.0 0.710 1 Default 0.73 1 Default 270 Existing Double Metal Clear Existing Living 2 Window 20.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 3 Window 30.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Existing Living 4 Window 4.0 0.710 Default 0.73 Default 0 Existing Double Metal Clear Existing Living 5 Window 35.0 0.710 Default 0.73 Default 0 Existing Double Metal Clear Existing Living 6 Window 40.0 0.710 Default 0.73 Default 0 Existing Double Metal Clear Existing Living 7 Window 20.0 0.710 Default 0.73 Default 0 Existing Double Metal Clear Existing Livin 8 Window 20.0 0.710 Default 0.73 Default 0 Existing Double Metal Clear Existing Living 9 Window 21.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear Existing Living 10 Window 4.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear Existing Living 11 Window 40.0 0.710 Default 0.73 Default 90 Removed Double Metal Clear Existing Living 12 Window 15.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear Existing Living 13 Window 93.4 0.710 Default 0.73 Default 90 Existing Double Metal Clear Existing Living 14 Window 40.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear Existing Living 15 Window 40.0 0.710 1 Default 0.73 Default 180 Removed Double Metal Clear Existing Living 16 Window 30.0 0.710 Default 1 0.73 Default 180 New Double Metal Clear I Existing Living (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Len H t LExt RExt Dist Len Right Fin H t Dist Len H t 1 Bug Screen 0.76 5.0 5.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 5.0 2.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 5.0 6.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 1.0 4.0 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 5.0 7.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 7 Bug Screen 0.76 5.0 4.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 5.0 4.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 3.0 7.0 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 1.0 4.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 3.0 5.0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 6.8 14.0 2.0 0.1 2.0 2.0 14 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0 15 Bug Screen 0.76 5.0 8.0 2.0 0.1 2.0 2.0 16 IBug Screen 0.76 5.0 6.0 2.0 0.1 2.0 2.0 EnergyPro 5.1 by Ener Soft User Number.- 2655 Runcode: 2011-04-19710:44:35 ID: Pae 7 of 13 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name Vershure Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 4/19/2011 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments 17 Window 13.5 0.710 Default 0.73 Default 180 Existing Double Metal Clear Existing Living 18 Window 10.0 0.710 Default 0.73 Default 180 Existing Double Metal Clear Existing Living 19 Window 53.4 0.710 Default 0.73 Default 90 New Double Metal Clear Addition (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Ove hang Left Fin Right Fin ID Exterior Shade Type SHGC Hat Wd Len Hat LExt RExt Dist Len Hat Dist Len Hat 17 Bug Screen 0.76 3.0 4.5 2.0 0.1 2.0 2.0 18 Bug Screen 0.76 2.0 5.0 2.0 0.1 2.0 2.0 19 Bug Screen 0.76 6.8 8.0 2.0 0.1 2.0 2.0 Ener Pro 5.1 by EnerqySoft User Number: 2655 RunCode: 2011-04-19710:44:35 ID: Page 8 of 13 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5) CF-1 R Project Name Vershure Residence Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 4/19/2011 BUILDING ZONE INFORMATION System Name Zone Name Floor Area ft New Existing Altered Removed Volume Year Built Living Zone Existing Living 2,838 25,542 1981 Addition 51 459 Totals 1 511 2,8381 01 0 HVAC SYSTEMS System Name Qty. I Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Living Zone 2 Central Furnace 78% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R-Value Ducts Tested? Status Living Zone Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas No Pipe Insulation 40,000 50 0.53 n/a n/a Existing MULTI-FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 0 .Z6 ¢ — System Name Pipe Length_ Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried Ener Pro 5.1 by Ener Soft User Number.' 2655 RunCode: 2011-04-19710:44:35 ID: Page 9 of 13 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Vershure Residence Date 1 4/19/2011 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116 (a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§150(c): Minimum R-13 insulation in wood -frame wall orequivalent Ll -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent LI -factor. 150(f): Air retarding wrap is tested, labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 1 50 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 erm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. §1500): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-13. §150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1 500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoff User Number: 2655 RunCode: 2011-04-19710:44:35 ID: Page 10 of 13 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date Vershure Residence 1411912011 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause de radation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150 k 2. §150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: LiQhting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2011-04-19710:44:35 ID: Page 11 of 13 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Vershure Residence 4/19/2011 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to 130 d . §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2011-04-19710:44:35 /D: Page 12 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Vershure Residence Date 4/19/2011 System Name Living Zone Floor Area 2,889 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL COOLING CFM Sensible Total Room Loads 2,428 50,763 Return Vented Lighting 0 Return Air Ducts 4,304 Return Fan 0 Ventilation 0 0 Supply Fan 0 Supply Air Ducts 4,304 TOTAL SYSTEM LOAD 1 59,371 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output per System 53,000 3,641 976 37,774 Total Output Btuh 106,000 Output Btuh/s ft 36.7 2,684 Cooling System 0 Output per System 42,000 07 0 0 Total Output Btuh 84,000 3,641 0 Total Output Tons 7.0 2,684 Total Output Btuh/s ft 29.1 Total Output s ft/Ton 412.7 43,141 Air System CFM per System 1,300 HVAC EQUIPMENT SELECTION Airflow cfm 2,600 Existing HVAC 62,957 10,670 106,000 Airflow cfm/s ft 0.90 Airflow cfm/Ton 371.4 Outside Air % 0.0% Total Adjusted System Output 1 62,957 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 10,670 1 106,000 Aug 3 PM Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 69 OF Outside Air 0 cfm Supply Fan 2,600 cfm 69 OF A 69 OF 107 OF Heating Coil 4 1 3 106 OF ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 80/64°F Outside Air Ar 0, cfm 80/64°F 80/64°F 57/56°F c c Supply Fan Cooling Coil 58 / 56 OF ..... ........_........... 2,600 cfm. 45.6% ROOM 78/64°F EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2011-0419710:44:35 /D: Page 13 of 13