BMCH2019-0292Tjht 4 Qa#&
VOICE (760) 777-7125
78-495 CALLE TAMPICO
D
LA QUINTA, CALIFORNIA
92253
FAX (760) 777-7011DESIGN
& DEVELOPMENT DEPARTMENT
INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 7/24/2019
Permit Type/Subtype:
MECHANICAL/
Owner:
Application Number:
BMCH2O19-0292
Declercq Martin / Declercq Christi
Property Address:
54275 AVENIDA RAMIREZ
54275 AVENIDA RAMIREZ
APN:
774243013
LA QUINTA, CA 92253
Application Description:
DECLERCQ/ HVAC CHANGEOUT
Property Zoning:
Application Valuation:
$14,000.00
Applicant: 0Contractor:
IE INC D
Q HARRISON ENTERPRISES INC DBA GENERAL AIR
31225 LA BAYA 31170 RESERVE DRIVE
WESTLAKE VILLAGE, CA 91362 JUL 2 4 2019 THOUSAND PALMS, CA 92276
CITY OF LAQUINTA DD (760)343-7488
DESIGN & DEVELOPMENT DEPARTMENT Llc. No.: 686310
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9
{commencing with Section 7000) of Division 3 of the Business and Professions Code, and
my License is in full force and effect.
License Class: C20, C36 License No.: 686310
Date: Z4 E� Contractor:_ ' c�.a uZy
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any
structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the
alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that he
or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to
construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State
License Law does not apply to an owner of property who builds or improves thereon,
and who contracts for the projects with a contractor(s) licensed pursuant to the
Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's
Lender's Address:
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
C� I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My workers' compensation insurance carrier and policy number are:
Carrier: CYPRESS INSURANCE COMPANY Policy Number: HAWC012965_
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: -g.; 1011 Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit issued
as a result of this application , the owner, and the applicant, each agrees to, and shall
defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not
commenced within 180 days from date of issuance of such permit, or cessation of work
for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the above -
mentioned property for inspection purposes.
Date: -�-f Signature (Applicant or Agent): -K-•
Date: 7/24/2019
Application Number:
BMCH2019-0292
Property Address:
54275 AVENIDA RAMIREZ
APN:
774243013
Application Description:
DECLERCQ / HVAC CHANGEOUT
Property Zoning:
Application Valuation:
$14,000.00
Applicant:
IE INC
31225 LA BAYA
WESTLAKE VILLAGE, CA 91362
Owner:
Declercq Martin / Declercq Christi
54275 AVENIDA RAMIREZ
LA QUINTA, CA 92253
Contractor:
HARRISON ENTERPRISES INC DBA GENERAL AIR
31170 RESERVE DRIVE
THOUSAND PALMS, CA 92276
(760)343-7488
Llc. No.: 686310
Detail: HVAC CHANGE OUT - 14SEER HEAT PUMP SPLIT SYSTEM. CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. 2016
CALIFORNIA BUILDING CODES.
FINANCIAL INFORMATION
❑ESCMPTION ACCOUNT QTY AMOUNT
BSAS SB1473 FEE 101-0000-20306 0 $1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
HVAC CHANGEOUT - SPLIT -SYSTEM
101-0000-42402
0
$40.02
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HVAC CHANGEOUT - SPLIT -SYSTEM PC
101-0000-42600
0
$80.05
Total Paid for CHANGEOUT: $120.07
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PERMIT ISSUANCE
101-0000-42404
0
$101.40
Total Paid for PERMIT ISSUANCE: $101.40
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RECORDS MANAGEMENT FEE
101-0000-42416
0
$10.00
Total Paid for RECORDS MANAGEMENT FEE: $10.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
ta Qa4qrCV
of,b, DFS ERT --
PERMIT#GEM
PLAN LOCATION:
Project Address: 54275 Avenue Ramirez
Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech
APN #:
Replace 4 ton heat pump
Applicant Name: Steven Schnierer
Address: 31225 La Baya Drive Suite 213
City, ST, Zip: Westlake Village, CA 91362
Telephone: 818-735-7876
Email: swschnierer@roadrunner.com
Valuation of Project $14,000.00
Contractor Name: General Air Conditioning
New SFD Construction:
Address: 31170 Reserve Drive
Conditioned Space SF
Garage SF
Patio/Porch SF
City, St, Zip Thousand Palms, CA 92276
Telephone: 760-343-7488
Email:
Fire Sprinklers SF
State Lie: 686310 City Bus Lie:
Arch/Eng Name:
Construction Type: Occupancy:
Address:
Grading:
City, St, Zip
Telephone:
Bedrooms:
Stories:
# Units:
Email:
State Lie: City Bus Lie:
Property Owner's Name: Martin De Clercq
New Commercial / Tenant Improvements:
Address: 54275 Avenue Ramirez
Total Building SF
City, ST, Zip La Quinta, CA 92253
Construction Type: Occupancy:
Telephone: 310-713-6811
Email:
78495 CALLE TAMPICO
LA QU I NTA, CA 92253
760-777-7000
OFFICE USE ONLY
#
Submittal
Req'd
Rec'd
Plan Sets
Structural Calcs
Truss Calcs
Title 24 Calcs
Soils Report
Grading Plan (PM10)
Landscape Plan
Subcontractor List
Grant Deed
HOA Approval
School Fees
Burrtec Debris Plan
Planning approval
Public Works approval
Fire approval
City Business License
DocuSlgn Envelope ID: 43E8C5D47443-4F5F-A3BE-94035941C469
.-... GENERAL
r'ttfCGNi11TIC) ttln;13!•°f41Nf.
•
Date-7'1a•ZQi9
City of La Quints
Department of Building and Safety
78495 Calle Tampico
La Quinta, CA 92253
Re: General Air Conditioning and Plumbing
Dear Permits Office:
I hereby authorize for General Air Conditioning and Plumbing to file for
and obtain a HVAC mechanical permit and/or a PLUMBING permit for my
property located at:
5 LI ?— 1 S A ven t&ee I eL z La Chu, v._-�&- c ojzz53
Name of Property Owner: i �. - -}-i r, L�
DocuSipncd by:
Property Owner Signature: u1G- d
7A13C708DB02C4A7
Date: 7/18/2019
CA
CERTIFICATE OF COMPLIANCE
Alterations to Space Conditioning Systems (formerly CF-IR-ALT HVAC)
Project Name:
MARTIN DE CLERCQ I Date Prepared:
CF1R-ALT-02-E
(Page 1 of 3)
2019-07-18
A. General Information
CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one
CF1R-AIT-02 document for each dwelling unit.
01
Project Name
MARTIN DE CLERCQ
02
Date Prepared
2019-07-18
03
Project Location
54275 AVENUE RAMIREZ
04
Building Type
Single family
05
CA City
La Quinta
06
Dwelling Unit Name
MARTIN DE CLERCQ
Dwelling UnitConditioned
07
Zip Code
92253
08
Floor Area (ft )
1416
Number of Space
09
Climate Zone
15
10
Conditioning (SC) Systems in
1
this Dwelling Unit:
B. Space Conditioning (SC) System Information
01
02
03
04
05
06
07
08
09
10
Is the SC
Installing a
SC System
SC System
CIA served
system a
refrigerant
Installing new SC
Installing
Installing
Installing
Identification or
Location or Area
by this SC
ducted
containing
system
more than 40
entirely new
entirely new
Name
Served
System (ftft)
system?
component?
components?
feet of ducts?
duct system?
SC system?
Alteration Type
System 1
Location 1
1416
Yes
Yes
Yes
No
No
No
Altered space
conditioning system
C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)iDiib)
This section does not apply to this project.
Registration Number: 419-A020075113A-000-000-0000000-0000
Registration Date/Time: 2019-07-18 14:40:48
HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-07-18 14:40:48
Schema Version: rev 20180426
CERTIFICATE OF COMPLIANCE CFlR-ALT 02-E
Alterations to Space Conditioning Systems (formerly CF-IR-ALT HVAC) (Page 2 of 3)
D. Altered Space Conditioning System (Sections 150.2(b)1E and F)
O1
02
03
04
05
06
07
08
09
10
11
12
Heating
Cooling
System
Heating
Altered
Heating
Minimum
Altered
Cooling
Minimum
Required
New or
Identification
System
Heating
Efficiency
Efficiency
Cooling
Cooling
Efficiency
Efficiency
Thermostat
Replaced
New Duct
or Name
Type
Components
Type
Value
System Type
Components
Type
Value
Type
Duct Length
R-Value
This field or
No Heating
This field or
This field or
Central split
All new
This field or
This field or
System 1
section is not
Component
section is not
section is not
HP
cooling
SEER
14
Setback
section is not
section is not
applicable
Altered
applicable
applicable
components
applicable
applicable
Required Documentation:
CF2R-MCH-01-E - Space Conditioning Systems
- Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16)
CF2R and CF3R-MCH-20-H - Duct Leakage Test required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced
-Leakage rate compliance: <=15 percent or <= 10 percent leakage to outside, or seal all accessible leaks.
CF2R and CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15).
CF2R and CF3R-MCH-23 Airflow Rate >= 300 CFM per ton required when MCH-25 is required.
Exceptions:
Duct systems registered with HERS provider as previously sealed are exempt from MCH-20 Duct Leakage Testing requirements.
Heating -only systems and Air Handler Furnace changes do not require verification of Air Flow MCH-23, or Refrigerant Charge MCH-25.
-Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH-20 Duct Leakage Testing requirements.
E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)1Diia and 150.2(b)lE, F)
This section does not apply to this project.
F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C)
This section does not apply to this project.
Registration Number: 419-A020075113A-000-000-0000000-0000 Registration Date/Time: 2019-07-18 14:40:48 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-07-18 14:40:48
Schema Version: rev 20180426
CERTIFICATE OF COMPLIANCE
CF1R-ALT 02-E
Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC) (Page 3 of 3)
Documentation Author's Declaration Statement
1.1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Brian Filice
Br%a Faic&
Company:
Signature Date:
I Permit E Raters
2019-07-18
Address:
CEA/ HERS Certification Identification (if applicable):
31225 La Baya Drive
RCN13060
City/State/Zip:
Phone:
Westlake Village CA 91362
818-735-7876
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer).
3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the
requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
5. I will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable
inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy.
Responsible Designer Name:
Responsible Designer Signature:
Patrick Somers
PCttrLck.Somers
Company:
Date Signed:
General Air Conditioning
2019-07-18
Address:
License:
31170 Reserve Drive
686310
City/State/Zip:
Phone:
Thousand Palms CA 92276
760-343-7488
Digitally signed by CHEERS"'. This digital signature is provided in order to secure the content of this registered
document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 419-A020075113A-000-000-0000000-0000
Registration Date/Time: 2019-07-18 14:40:48
HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-07-18 14:40:48
Schema Version: rev 20180426