BMCH2019-030778-49`. CALLE TAMPICO " 0 D `1 - VOICE (760) 777-7125
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011
DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 7/31/2019
Permit Type/Subtype: MECHANICAL/ Owner:
Application Number: BMCH2O19-0307 RANDALL & CATHERINE BOYD
Property Address: 45055 RAMBLEWOOD CT CT 45055 RAMBLEWOOD COURT
APN: 604291015 LA QUINTA, CA 92253
Application Description: BOYD / HVAC CHANGE OUT - 20SEER/80AFUE SPLIT SYSTEM
Property Zoning:
Application Valuation: $10,237.00
Applicant: Contractor:
IE INC. ESSER SERVICES INC DBA ESSER AIR CONDITI
32115 LA BAYA P 0 BOX 1636
WESTLAKE VILLAGE, CA 91362 JUL 3 1 20,9 CATHEDRAL CITY, CA 92235
CITY OF LA QUINTA (760)324-0550
DESIGN & DEVELOPMENT DEPARTMENT Llc. No.: 489046
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9
{commencing with Section 70001 of Division 3 of the Business and Professions Code, and
my License is in full force and effect.
License Class: C20 License No.: 4
Date: 31 i Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any
structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the
alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that he
or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to
construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State
License Law does not apply to an owner of property who builds or improves thereon,
and who contracts for the projects with a contractor(s) licensed pursuant to the
Contractors' State License Law.).
(_) I am exempt under Sec. B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's
Lender's Add
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My workers' compensation insurance carrier and policy number are:
Carrier: INSURANCE COMPANY OF THE WEST Policy Number:WSD503016704
_ I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: J 51 ( Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit issued
as a result of this application , the owner, and the applicant, each agrees to, and shall
defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not
commenced within 180 days from date of issuance of such permit, or cessation of work
for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the above -
mentioned property for inspection purposes. ��•
Date: Signature (Applicant or Agent):
Date: 7/31/2019
Application Number:
BMCH2019-0307
Property Address:
45055 RAMBLEWOOD CT CT
APN:
604291015
Application Description.
BOYD / HVAC CHANGE OUT - 20SEER/80AFUE SPLIT SYSTEM
Property Zoning:
Application Valuation:
$10,237.00
Applicant:
IE INC.
32115 LA BAYA
WESTLAKE VILLAGE, CA 91362
Owner:
RANDALL & CATHERINE BOYD
45055 RAMBLEWOOD COURT
LA QUINTA, CA 92253
Contractor:
ESSER SERVICES INC DBA ESSER AIR CONDITI
P 0 BOX 1636
CATHEDRAL CITY, CA 92235
(760)324-0550
Llc. No.: 489046
Detail: 5-TON HVAC CHANGE OUT - 20 SEER/80 AFUE SPLIT SYSTEM. CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. PER
2016 CALIFORNIA BUILDING CODES.
DESCRIPTION ACCOUNT CITY AMOUNT
BSAS SB1473 FEE 101-0000-20306 0 $1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
HVAC CHANGEOUT - SPLIT -SYSTEM
101-0000-42402
0
$40.02
DESCRIPTION
ACCOUNT
CITY
AMOUNT
HVAC CHANGEOUT - SPLIT -SYSTEM PC
101-0000-42600
0
$80.05
Total Paid for CHANGEOUT: $120.07
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PERMIT ISSUANCE
101-0000-42404
0
$101.40
Total Paid for PERMIT ISSUANCE: $101.40
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RECORDS MANAGEMENT FEE
101-0000-42416
0
$10.00
Total Paid for RECORDS MANAGEMENT FEE: $10.00
DESCRIPTION ACCOUNT
CITY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE 502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
a& Qa4fra
— cEM f,b, DEsLWr —
PERMIT # 1�'� � 1 `" Q 30
PLAN LOCATION-
Project Address: 45055 Ramblewood Court
Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech
APN #:
Replace 5 ton / 80,000 BTU complete HVAC system
Applicant Name: Steven Schnierer
Address: 31225 La Baya Drive Suite 213
City, ST, Zip: Westlake Village, CA 91362
Telephone: 818-735-7876
Email:
swschnierer@roadrunner.com
Valuation of Project $10,234,00
-
Contractor Name: Esser Services Inc
New SFD Construction:
Address: PO Box 1636
Conditioned Space SF
City, St, Zip Cathedral City, CA 92235
Garage SF
Telephone: 760-324-0550
Patio/Porch SF
Email:
Fire Sprinklers SF
State Lie: 489046 City Bus Lie:
Arch/Eng Name:
Construction Type: Occupancy:
Address:
Grading:
City, St, Zip
Telephone:
Bedrooms:
Stories:
# Units:
Email:
State Lie: City Bus Lie:
Property Owner's Name: Randy Boyd
New Commercial / Tenant Improvements:
Address:45055 Ramblewood Court
Total Building SF
City, ST, Zip La Quinta, CA 92253
Construction Type: Occupancy:
Telephone: 760-702-5498
Email:
78495 CALLE TAMPICO
LA QU I NTA, CA 92253
760-777-7000
OFFICE USE ONLY
#
Submittal Req'd
Plan Sets
Rec'd
Structural Calcs
Truss Calcs
Title 24 Calcs
Soils Report
Grading Plan (PM10)
Landscape Plan
Subcontractor List
Grant Deed
HOA Approval
School Fees
Burrtec Debris Plan
Planning approval
Public Works approval
Fire approval
City Business License
DocuSign Envelope ID: 4E33E6CF-FF1 B-4F9F-9FC3-7401 DA64CAC8
Esser Services Inc.
t
PO Box 1636
i
Cathedral City, CA 92235
Ain GQNPlT10NIH0
License # 489046
•nd HEATING
•
Customer information
Date 6-12-2019
Name Cathy and Randy Boyd
Address 45055 Ramblewood Ct
i Includes the Fallowmonsuml=in
Home Improvement
Contract
Email co urageoushealers@gmaii.com
Phone 760-702-7616 I Phone
City I La Quinta State F CA
0HER5 Test (T"` Party)
I3Acid Flush Existing Line set
EnCity Permit
0Liquid Line Drier(s)
EICode Compliant Install
ODisconnect Box(s)**
[:]Crane
LlFuses
®Remove Old Equipment
23Electrical Whip(s)-230v**
®Jobsite Clean-up
OCondenser Pad(s)*
EnCO2 detector
❑ New Line Set (proper size)
05eal ceiling cans*
❑Line Set Cover*
❑Insulate return Plenum*
OThermostat*** (see scope
❑FAU Filter Base*
0 New Low Voltage Wire**
Eaulnment Overview
0 No -Vent locking caps
BElectrical Pigtail(s)-115v**
®Furnace Flu Vent
OGas Flex & Service Valve**
013ackup Drain Pan
*New Supply Plenum***
®New Return Plenum***
®Standard Air Filter
❑ Bar Type Supply Rel
❑ Bar Type Return Gri
92253
OCeiling Saver- Water Switch
El FAU sheet metal platform
OSystem Startup
0 Refrigerant Charge
OHeat/Cool System Test
_ ❑Jobsite Inspection
g] 2 Supply Duct Run(s)*
❑ Return Duct Run(s)*
❑New Condensation Pump
Condenser
TRANE
Cooling Stgs.
VS
Compressor Warranty
( Year
Model #
USED
Heating Stgs.
2
Parts Warranty
(10 )Year
Outdoor
PCKG Unit
Ultra -Quiet
YES
Coil Warran
00 )Year
Model #
NA
Communicating
YES
I Labor Warranty
(5 )Year
FAU
TRANE
More Misc. Details
FAU
Model #
TUD2C100`
Variable Speed Indoor YES Gas/Electrlc
YES
J AFUE
80%
_
Variable Speed Outdoor YES Heat Pump
NO
Brand
ADP
Weather Proof To YES
Indoor
-
Position
LEFT
Thermostat Upgrade
Type
I
WIN
$
Energy
Efficiency
Air Quality
I Electronic
$
t &
Electrical Protection
Type
$
Equipment
Extended Labor Warranty
Length
❑5 Yr. ❑ 20Yr. ❑ 12 Yr.
$
Protection
Other
Describe
S
Scope of work A aneral dexcri ion of the work to be done)
Y s I $0A0
ESSER TO INSTALL USED 5 TON XV20 CONDENSER, NEW XC80 FURNACE, AND ADP COIL. REPLACE EXISTING RETURN WITH A 20"
DUCT, AND ADD A NEW RETURN TO THE MASTER BEDROOM(16" duct to 20x20 rfg). NEW PLENUMS TO BE ADDED TO THE RETURN AND
THE SUPPLY. NO ALTERATION TO EXISTING DUCTING. XL1050 THERMOSTAT TO BE USED. CODE ITEMS TO BE ADDRESSED.
RECCOMEND DUCT CLEANING PRIOR TO TO INSTALLATION.
Approximate Start Date TBD
Billing
�10,234.00 Eauipment Price
$0.00
$ 0.00
$ 0.00
$10,234.00
Completion Date I TBD
91111ne Details
Total Options
Manufacturer Instant Rebates / Esser Instant Rebates
Down Payment (10 percent or $1,000, whichever is less)
Total Amount Due Upon Completion (Includes Tax
Method ❑CC ❑ Csh ❑ Chk ❑ Othr
YGrene El Yr. ❑ 10 Yr. 1115 Yr.
HERO 05 Yr. ❑ 10 Yr. ❑ 15 Yr.
Financing % 8.9 APR for _ Months
Check # Last 4 CC
Customer
r4Mer Aparoval
Cathy Boyd
Customer Print _
Esser Rep, michael esser
6/14/2019
Date
Date 1 6-12-2019
DocuSign Envelope ID: 4E33E6CF-FF1 B-4F9F-9FC3-7401 DA64CAC8
ARBITRATION OF DISPUTES AND IN-HOUSE DISPUTES
By initialing below (Arbitration of Disputes area) you are agreeing to have any dispute resolved between owner and contractor and
that no reviews will be permitted over the internet and will NOT be written. Notice: By initialing in the space below you are agreeing
to have any dispute arising out of the matters included in the "Arbitration as provided by California law and you are giving up any
rights you might possess to have the dispute litigated in a court or jury trial. "By initialing in the space below you are giving up your
judicial rights to discovery and appeal, unless those rights are specifically included in the after agreeing to this provision, you may be
compelled to arbitrate under the authority of the business and professions code or other applicable laws. Your agreement to this
arbitration provision is voluntary. "We have read and understand the foregoing and agree to submit disputes arising out of the matters
included in the "ArjZitration of Disputes" Provision to neutral arbitration"
Customer initiG� Date: 6/14/2019
COMMERCIAL GENERAL LIABILITY INSURANCE
This contractor carries commercial general liability insurance written by CastlePoint National Insurance Company. You may call
CastlePoint National Insurance Company at 866-481-9363 to check the contractor's insurance coverage.
WORKERS' COMPENSATION INSURANCE
This contractor carries workers' compensation insurance for all its employees.
MECHANICS LIEN WARNING
Anyone who helps improve your property, but who is not paid, may record what is called a mechanics' lien on your property. A
mechanics' lien is a claim, like a mortgage or home equity loan, made against your property and recorded with the county recorder.
Even if you pay your contractor in full, unpaid subcontractors, suppliers, and laborers who helped to improve your property may
record mechanics' liens and sue you in court to foreclose the lien. If a court finds the lien is valid, you could be forced to pay twice or
have a court officer sell your home to pay the lien. Liens can also affect your credit.
To preserve their right to record a lien, each subcontractor and material supplier must provide you with a document called a '20-day
Preliminary Notice.' This notice is not a lien. The purpose of the notice is to let you know that the person who sends you the notice
has the right to record a lien on your property if he or she is not paid.
BE CAREFUL. The Preliminary Notice can be sent up to 20 days after the subcontractor starts work or the supplier provides material.
This can be a big problem if you pay your contractor before you have received the Preliminary Notices. You will not get Preliminary
Notices from your prime contractor or from laborers who work on your project. The law assumes that you already know they are
improving your property.
PROTECT YOURSELF FROM LIENS. You can protect yourself from liens by getting a list from your contractor of all the subcontractors
and material suppliers that work on your project. Find out from your contractor when these subcontractors started work and when
these suppliers delivered goods or materials. Then wait 20 days, paying attention to the Preliminary Notices you receive.
PAY WITH JOINT CHECKS. One way to protect yourself is to pay with a joint check. When your contractor tells you it is time to pay for
the work of a subcontractor or supplier who has provided you with a Preliminary Notice, write a joint check payabie to both the
contractor and the subcontractor or material supplier.
For other ways to prevent liens, visit CSLB's website at www.cslb.ca.gov or call CSLB at 1-800-321-CSLB (2752). Remember, if you do
nothing, you risk having a lien placed on your home. This can mean that you may have to pay twice, or face the forced sale of your
home to pay what you owe.
INFORMATION ABOUT THE CONTRACTORS STATE LICENSE BOARD (CSLB)
CSLB is the state consumer protection agency that licenses and regulates construction contractors. Contact
CSLB for information about the licensed contractor you are considering, including information about
disclosable complaints, disciplinary actions and civil judgments that are reported to CSLB. Use only licensed
contractors. If you fi le a complaint against a licensed contractor within the legal deadline (usually four years),
CSLB has authority to investigate the complaint. If you use an unlicensed contractor, CSLB may not be able to
help you resolve your complaint. Your only remedy may be in civil court, and you may be liable for damages
arising out of any injuries to the unlicensed contractor or the unlicensed contractor's employees.
For more information:
VISIT CSLB's website at www.csl_b.ca.goy
CALL CSLB at 1-800-321-CSLB (2752)
WRITE CSLB at P.O. Box 26000, Sacramento, CA 95826
THREE-DAY RIGHT TO CANCEL
You, the buyer, have the right to cancel this contract within three business days. You may cancel by e-mailing,
mailing, faxing, or delivering a written notice to the contractor at the contractor's place of business by
midnight of the third business day after you received a signed and dated copy of the contract that includes this
notice. Include your name, your address, and the date you received the signed copy of the contract and this
notice. If you cancel, the contractor must return to you anything you paid within 10 days of receiving the
nntirp of rnnrellation. For vour Dart. you must make available to the contractor at your residence, in
DocuSign Envelope ID: 4E33E6CF-FF1B-4F9F-9FC3-7401DA64CAC8
A NOTE ABOUT EXTRA WORK AND CHANGE ORDERS
Extra work and Change Orders become part of the contract once the order is prepared in writing and signed by the parties prior to
commencement of any work covered by the new change order. The order must describe the scope of the extra work or change, the
cost to be added or subtracted from the contract, and the effect the order will have on the schedule of progress payments
Exclusions:
Please Note: Next to customer satisfaction, Esser prides itself in being upfront with its customers and placing everything on the table
prior to signing a proposal or starting work. Estimating in the construction field, by nature is very limited to what we are able to see at
the time of the estimate. We are not able to bid something we are not able to see. The below exclusions are a description of things that
we MIGHT possibly run across once the equipment is removed. It is very rare that Esser AC finds serious issues once the equipment is
removed, as we do our best to catch every potential obstacle before the install is performed. Each of the below are subject to individual
review on a case by case basis. Esser ultimately reserves the right to cancel the contract at any time for any reason. Esser is under no
obligation to absorb the cost of extra work needed OUTSIDE the written scope of work above.
Owner to provide the following/Disclaimers
1. HERS Duct rater (if needed) See P,2
2. Performed by [Permit eRaters or similar company.
1. They will be calling you within 4 weeks of your installation
2. $250.00 Per system (residential only, paid for by customer unless otherwise specified in proposal)
3. $300.00 Per system (commercial only, paid for by business unless otherwise specified in proposal)
3. All upgrades to the system or jobsite that are not listed in the proposal.
1. Esser will be using existing HIGH and LOW voltage wiring, unless otherwise specified in proposal.
1. Like other items, the low voltage wiring may be condemned during installation if its overall integrity is found to
be poor and not in useable condition. Continuity testing can generally notify installers of potential issues.
Sometimes low voltage shorts may not present themselves during the time of installation. If low voltage wiring
is not listed in the scope of work, it may be subjected to extra costs.
2. However, not all issues are able to be detected. In fact, the low voltage wire may be okay at the time of
installation and defect later. Existing Items are not covered under warranty. High voltage to be referred out to
a licensed electrician at the owner's expense.
2. Condensation piping and/or draining systems-
1. Esser will use existing condensate, unless otherwise specified in proposal.
1. If it is discovered the condensate is not in reusable condition during installation, installation of new
condensate pipe will be subject to extra cost.
2. Often there is no way to predict a condensation plug or blockage, even during a new installation. We
will always make sure that the system is draining properly at the time of installation, but can in
absolutely no possible way can guarantee that it will stay unplugged. There are too many outside
factors, separate from the installation that could cause drain issues.
3. In the case of condensation drain blockage or leak due to outside factors, Esser will not be held
responsible for repairs needed to drywall, paint, etc.
3. Esser will be using existing ducting, unless otherwise specified in proposal.
1. Ducting recommendations will be made and area separate item from the equipment install.
1. ALL ducting upgrades will be subject to extra cost.
2. NOTE: Ducting may not always be accessible. If a run is not accessible, it will not be replaced.
3. If HERS cannot pass inspection, extra repairs and replacements are subject to extra costs.
4. Esser will be using existing line set, unless otherwise specified In proposal.
1. Any upgrades to existing line set will be subject to extra cost.
2. Note: Due to the nature of our work, copper line sets may be condemned during the installation process once
the system is opened up and the copper tubes are further inspected.
4. Esser is not responsible for pre-existing platform/roofing damage or conditions
1. During installation, if Esser Installers deems the platform unstable or in poor condition, the upgrades and repairs will
be subject to extra cost.
2. Please understand that Esser can only do a visual inspection. Once the unit is removed from the platform, Esser can
do a further inspection of the platforms integrity. Platforms are not included, unless other specified.
5. Installation work:
1. Esser not responsible for paint matching or painting anything that needs touch up paint.
2. Installation are to be performed between normal working hours unless otherwise approved. 8AM-5PM M-F
6. Warranty Work:
1. Warranty work is only done 7:30AM-5PM M-F.
2. Warranty work Is not completed on recognized holidays.
3. Items not related to installation of scope of work are not included in Esser warranty.
7. Payment:
1. Payment is due upon completion of work within 10 days.
2. Lien releases are not provided until payment is received and processed.
8. Repairs/modifications including roofs, landscaping, wires buried under insulation or the ground, windows etc.
1. Extra foaming, Tar, tile roof, interior paint, exterior paint, or anything not listed in the proposat-
1. If walking on the roof, homeowner or HOA must provide reasonable access over the the roof. If there is no
reasonable access to the unit on the roof, and tiles are broken, Esser AC will not be held responsible.
2. Roof Screening: Esser will use existing screening on roof or front yard. However, if no screening exists, then
customer will be responsible for hiring and providing code compliant screening around the condenser or package unit
on the roof or ground.
9. Home Intelligence: Customer is responsible for notifying Esser of a pre-existing home intelligencelmonitoring system prior to
Esser installation via written notice. Nexia Z-wave is proprietary and only compatible with the Nexia platform at this time. Esser
CERTIFICATE OF COMPLIANCE
Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC)
Project Name:
RANDY BOYD I Date Prepared:
CF1R-ALT 02-E
(Page 1 of 3)
2019-06-25
A. General Information
CHR-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one
CF1R-ALT-02 document for each dwelling unit.
01
Project Name
RANDY BOYD
02
Date Prepared
2019-06-25
03
Project Location
45055 RAMBLEWOOD CT
04
Building Type
Single family
05
CA City
La Quinta
06
Dwelling Unit Name
RANDY BOYD
Dwelling Unit Conditioned
07
Zip Code
92253
08
Floor Area (ft)
2008
Number of Space
09
Climate Zone
15
10
Conditioning (SC) Systems in
1
this Dwelling Unit:
B. Space Conditioning (SC) System Information
01
02
03
04
05
06
07
08
09
10
Is the SC
Installing a
SC System
SC System
CIA served
system a
refrigerant
Installing new SC
Installing
Installing
Installing
Identification or
Location or Area
by this SC
ducted
containing
system
more than 40
entirely new
entirely new
Name
Served
System (ftZ)
system?
component?
components?
feet of ducts?
duct system?
SC system?
Alteration Type
System 1
Location 1
2008
Yes
Yes
Yes
No
No
No
Altered space
conditioning system
C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)1Diib)
This section does not apply to this project.
Registration Number: 419-A020065330A-000-000-0000000-0000
Registration Date/Time: 2019-06-25 13:00:45
HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-06-25 13:00:45
Schema Version: rev 20180426
CERTIFICATE OF COMPLIANCE
CUR-ALT-024
Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC)
(Page 2 of 3)
D. Altered Space Conditioning System (Sections 150.2(b)1E and F)
01
02
03
04
I 05
06
07
08
09
10
11
12
Heating
Cooling
System
Heating
Altered
Heating
Minimum
Altered
Cooling
Minimum
Required
New or
Identification
System
Heating
Efficiency
Efficiency
Cooling
Cooling
Efficiency
Efficiency
Thermostat
Replaced
New Duct
or Name
Type
Components
Type
Value
System Type
Components
Type
Value
Type
Duct Length
R-Value
All new
All new
This field or
This field or
System 1
Central gas
heating
AFUE
0.8
Central split
cooling
SEER
20
Setback
section is not
section is not
furnace
components
AC
components
applicable
applicable
Required Documentation:
CF2R-MCH-01-E - Space Conditioning Systems
- Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16)
CF2R and CF3R-MCH-20-H - Duct Leakage Test required when heating or cooling components are Installed in ducted systems, or when more than 40 ft of duct length is replaced
-Leakage rate compliance: <= 15 percent or <= 10 percent leakage to outside, or seal all accessible leaks.
CF2R and CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15).
CF2R and CF3R-MCH-23 Airflow Rate >= 300 CFM per ton required when MCH-25 is required.
Exceptions:
Duct systems registered with HERS provider as previously sealed are exempt from MCH-20 Duct Leakage Testing requirements.
Heating -only systems and Air Handler Furnace changes do not require verification of Air Flow MCH-23, or Refrigerant Charge MCH-25.
-Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH-20 Duct Leakage Testing requirements.
E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)iDiia and 150.2(b)1E, F)
This section does not apply to this project.
F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C)
This section does not apply to this project.
Registration Number: 419-A020065330A-000-000-0000000-0000
Registration Date/Time: 2019-06-25 13:00AS
HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-06-25 13:00:45
Schema Version: rev 20180426
CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E
Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC) (Page 3 of 3)
Documentation Author's Declaration Statement
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Jo Anne Orona
J&An*le-orona.
Company:
Signature Date:
I Permit E Raters
2019-06-25
Address:
CEA/ HERS Certification Identification (if applicable),
31225 La Baya Drive
City/State/Zip:
Phone -
Westlake Village CA 91362
818-735-7876
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer).
3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the
requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
5. 1 will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable
inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy.
Responsible Designer Name:
Responsible Designer Signature:
Shantel Faugno
Sha.nteLFauq+i&
Company:
Date Signed:
Esser Services, Inc.
2019-06-25
Address:
License:
PO Box 1636
489046
City/State/Zip:
Phone:
Cathedral City CA 92235
760-324-0550
Digitally signed by CNEERSTM. This digital signature is provided in order to secure the content of this registered
document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 419-A020065330A-000-000-0000000-0000 Registration Date/Time: 2019-06-25 13:00:45 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-06-25 13:00:45
Schema Version: rev 20180426