Loading...
BRES2019-007878-495 CALLE TAMPICO C& 0 D e6P Q" LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Permit Type/Subtype: BUILDING RESIDENTIAL/DWELLING - SINGLE FAMILY DETACHED Application Number: BRES2019-0078 Property Address: 52085 AVENIDA CORTEZ APN: 773201017 Application Description: CORONEL / 2086SF DWELLING - [VB/RES-3/CLASS A-FR/13D Property Zoning: Application Valuation: $135,717.10 Applicant: a CORONEL ENTERPRISES INC D 42760 MADIO STREET JUL 2 2 2019 INDIO, CA 92201 CITY OF LA QUINTA DESIGN & DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. \ p License Class: License No.::CONV:k40528101254134705 Date:��- 1Z -- ` t Contractor: � , OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work.for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 7/22/2019 Owner: CORONEL ENTERPRISES INC 42760 MADIO STREET INDIO, CA 92201 Contractor: CORONEL ENTERPRISES INC 42760 MADIO STREET INDIO, CA 92201 (760)775-1234 Llc. No.::CONV:140528101254134705 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compenF�have on, as provided for by Section 3700 of the Labor Code, for the performance of wfor which this permit is issued. and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier:_ Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject tp44workers' compensation laws of California, and agr that, if I should becom ubj t to the workers' compensation provisions of Sec i n 37 0 of the ab'ar Co e, I ail forthwith comply with those provisions. Date: — Applicants-� J WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of " ty to ter u 57r th boYe- mentioned property for inspection purposes. Date: 7 `7-L ` Signature (Applicant or Agent): Date: " 7/2i/1019 Application Number: BRES2019-0078 Property Address: 52085 AVENIDA CORTEZ APN: 773201017 Application Description: CORONEL / 2086SF DWELLING - [VB/RES-3/CLASS A-FR/13D Property Zoning: Application Valuation: $135,717.10 Applicant: CORONEL ENTERPRISES INC 42760 MADIO STREET INDIO, CA 92201 Owner: CORONEL ENTERPRISES INC 42760 MADIO STREET INDIO, CA 92201 Contractor: CORONEL ENTERPRISES INC 42760 MADIO STREET INDIO, CA 92201 (760)775-1234 LIc. No.::CONV:140528101254134705 Detail: 2,086SF DWELLING - [VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES NOT INdUOE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 2016 CALIFORNIA BUILDING CODES. pan�7aMU00 j❑f10'M) p 1� d` Y`r ley, INFORMATIONF FINANCIAL DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $6.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $6.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - CIVIC CENTER 252-0000-43200 0 $942.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - LIBRARIES 253-0000-43200 0 $344.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - PARKS/REC 251-0000-43200 0 $2,048.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 Total Paid for DIF - SINGLE FAMILY DWELLING: $6,778.00 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0 $27.22 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF, PC 101-0000-42600 0 $11.20 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $160.10 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $52.83 Total Paid for ELECTRICAL - NEW CONSTRUCTION: $251.35 DESCRIPTION ACCOUNT CITY AMOUNT CONDENSER/COMPRESSOR 101-0000-42402 0 $40.02 DESCRIPTION ACCOUNT CITY AMOUNT CONDENSER/COMPRESSOR PC 101-0000-42600 0 $26.68 DESCRIPTION ACCOUNT CITY AMOUNT EXHAUST HOOD 101-0000-42402 0 $13.34 DESCRIPTION ACCOUNT CITY AMOUNT EXHAUST HOOD PC 101-0000-42600 0 $5.34 DESCRIPTION ACCOUNT CITY AMOUNT FURNACE 101-0000-42402 0 $40.02 DESCRIPTION ACCOUNT CITY AMOUNT FURNACE PC 101-0000-42600 0 $26.68 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN 101-0000-42402 0 $66.70 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN PC 101-0000-42600 0 $26.70 Total Paid for MECHANICAL: $245.48 DESCRIPTION ACCOUNT QTY AMOUNT MULTI -SPECIES RESIDENTIAL 0-8 UNITS - 2018 UPDATE 101-0000-20310 0 $1,290.00 Total Paid for MULTI -SPECIES RESIDENTIAL: $1,290.00 DESCRIPTION ACCOUNT QTY AMOUNT NEW CONSTRUCTION PERMIT 101-0000-42400 0 $584.51 Total Paid for NEW CONSTRUCTION PERMIT: $584.51 DESCRIPTION ACCOUNT QTY AMOUNT NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $1,170.18 Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,170.18 DESCRIPTION ACCOUNT QTY AMOUNT PLAN CHECK DEPOSIT- RESIDENTIAL 101-0000-42600 1 $750.00 Total Paid for PLAN CHECK DEPOSIT - RESIDENTIAL: $750.00 DESCRIPTION ACCOUNT QTY AMOUNT BACKFLOW DEVICE 101-0000-42401 0 $13.34 DESCRIPTION ACCOUNT QTY AMOUNT BACKFLOW DEVICE PC 101-0000-42600 0 $5.34 DESCRIPTION ACCOUNT QTY AMOUNT BUILDING SEWER 101-0000-42401 0 $26.68 DESCRIPTION ACCOUNT QTY AMOUNT BUILDING SEWER PC 101-0000-42600 0 $18.68 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $173.42 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $173.42 DESCRIPTION ACCOUNT QTY AMOUNT GAS SYSTEM, 5+ OUTLETS 101-0000-42401 0 $40.02 DESCRIPTION ACCOUNT QTY AMOUNT GAS SYSTEM, 5+ OUTLETS PC 101-0000-42600 0 $26.68 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT 101-0000-42401 0 $13.34 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT PC 101-0000-42600 0 $8.00 Total Paid for PLUMBING FEES: $498.92 DESCRIPTION ACCOUNT QTY AMOUNT RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 $21.00 Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 DESCRIPTION I ACCOUNT I QTY I AMOUNT SMI - RESIDENTIAL 1101-0000-20308 f 0 f $17.64 Tw. 1 n..:J [w- C nAw1I+ w aaaraw Zvi . InvlvV Irlw I ladlm IIYa I nulvirlY 1 NIIVIY,71V11: ryl JL 04 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($750.00) DESCRIPTION ACCOUNT CITY AMOUNT SINGLE FAMILY DETACHED 2018 UPDATE 224-0000-20320 0 $750.00 DESCRIPTION ACCOUNT CITY AMOUNT SINGLE FAMILY DETACHED 2018 UPDATE 224-0000-20320 0 $1,560.00 Total Paid for TUMF - RESIDENTIAL: $1,560.00 0: aPERMIT# CAI WORNIt1 ta PLAN LOCATION: Project Address: C� a Q��� �e Z Project Description: APN #: 7 -a-w —o � Applicant Name: Ln�lcon� Address: 'I D-`7G() MAt u S City, ST, Zip: 0-0 I Telephone: 7(o -'77 5 - 1 -2 -:� k Email: %S� C. e� 4?rV - . C a Valuation of Project $ Contractor Name: New SFD Construction: Address: l-k �� 0. Conditioned Space �SF City, St, Zip O Garage �_SF Telephone: ,,7� Patio/Porch SF Email: 15�@ C4TaA Fire Sprinklers SF State Lic: 7a-7 i fl City Bus Lic: Architect/Engineer Name:��q a Construction Occupancy: Address: �)�) ,k Grading: City, St, Zip �- Telephone: G Bedrooms: Stories: # Units: Email: State Lic: City Bus Lic: Property Owner's Name: co�� �� New Commercial / Tenant Improvements: Address: �'A'a-7(0 M 4 �, ,, S Total Building SF City, ST, Zip � a ? a )_Q Construction Type: Occupancy: Telephone: 76a-77S--I -)_3 Y Email: tS�e CQCC J-eJ 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 OFFICE USE ONLY # Submittal Required Received Plan Sets Structural Calcs Truss Calcs Title 24 Calcs Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road Date: 7/22/2019 La Quinta, CA 92253 No.: 19-01413-1 (760)771-8515 Owner: Coronel Enterprises Email: Address: 52085 Avenida Cortez Jurisdiction: La Quinta City: La Quinta Tract #: Type: Single Family Residential Lot # Street No. Street Name 52085 Avenida Cortez RECEIVED JUL 2 2 2019 CITY OF LA QUINTA DESIGN AND DEVELOPMENT DEPARTMENT Comments: Sq. Feet APN 2086 773-201-017 Permit No. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement mobile homes. It has been determined that the a bove-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fess imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $3.79 X 2086 S.F. or $7,905.94 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued. Fees Paid B Check No.: 7015363 y: S�.R�bobankf�h Coronel Bank Name/Recipient of Certificate Telephone: 760-578-3367 Funding: Residential By Scott L. Bailey Superintendent Fee Collected/ Exempted by: Rodney Slagle Certificate Fees Due: $7,905.94 Original Payment(s) Rec'd: $0.00 New Payment Rec'd: $7,905.94 Over%Under: $0.00 NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 9D-day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL. �3 f Building Permit Number: 15C Zvlq — U % Project Description: SFR Exempt: ❑ (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan Plan Submittal Date 7/2/2019 Job Site Owner's Name Number, Street, or PO Box City, State, Postal Code Owner's Phone Number Owner's E-Mail Address Project Manager's Name Project Manager's Phone Number Project Manager's E-mail Address Builder / Contractor Number, Street or PO Box City, State, Postal Code Project Square Footage City Approval By Date of City Approval 52085 Avenida Cortez Desert Dunes LLC 52085 Avenida Cortez La Quinta, CA. 92253 c/o 760-775-1234 Ish Coronel 760-775-1234 corn n eloff ceo co rune lent, com Coronel Enterprises Inc. 42760 Madio St. Indio, CA. 92201 Approx. 2,086 sf Renado Gouldlock-DEC/Burrtec Was t^ 0- 1 / Materials To Be Discarded: Product Tons Trash 7.50 Not recyclable Asphalt 0.00 Recyclable Brick/Block ! 0.00 Recyclable Cardboard 0.00 Recyclable Commingled 0.00 Recyclable Concrete 8.00 Recyclable Drywall 1.00 Recyclable Donated / Reuse* 0.00 Recyclable "Describe Items Product Tons Masonry (broken) 0.00 Plaster 2.50 Scrap Metal 0.00 Tile (floor) 0.20 Tile (roof) 0.30 Wood 3.25 Landscape Debris 0.00 Totals: Recycle Trash Projected Diversion: 15.3 1 7.5 67.03°/0 I understand it is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued in the name of the properW owner(s) and the owner retains legal responsibility for ensuring that the provisions of the P a adhered to. the p e owner(s) and general contractor shall be kept informed of the diversion progress through tii- ont y reports. If s f-ha li all refuse material from this project site must be taken to an approved recycler or transfer ner l Developer! Project Manager / Superintendant Date RECORDING REQUESTED BY WHEN RECORDED MAIL THIS DOCUMENT AND TAX STATEMENTS TO: Coronel Enterprises, Inc. 42760 Madio Street Indio, California 92201 APN: 773-201-017 TRA: 20-017 GRANT DEED THE UNDERSIGNED GRANTOR(S) DECLARE(S) DOCUMENTARY TRANSFER TAX IS $0.00 ❑x City of La Quinta, AND 2019- 0268289 07/18/2019 03:42 PM Fee: $ 92.00 Page 1 of 2 Recorded in Official Records County of Riverside Peter Aldana Assessor -County Clerk -Recorder 1111N�R1�116 I I I I Space above this line for Recorder's use FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Desert Dunes LLC, an Idaho limited liability company hereby GRANT(S) to Coronel Enterprise, Inc. the following described real property in the County of Riverside, State of CALIFORNIA: For legal description of the real property herein, see Exhibit A attached hereto and made a part hereof. Commonly known as: APN: 773-201-017, La Quinta, California 92253 Dated: July 9, 2019 Desert Dunes LC, h Idaliddlimited liability company By: Greg G rvais, Member A notary public or other officer completing this certificate verifies only the Identity of the individual who signed the document to which this certificate is attached, and not the truthfulness, accuracy, or validity of that document. STATE OF CALIFORNIA j COUNTY OF ) SS. . k ���� ) On before me, Notary Public, personally a p pea rbd _ ' _ .T' � f who proved to me on thcbasis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WITNESS my hand and official seal. e r1 BRAND. NOTARY PUBLIC _ :1DAH0 COMMISSIO-' I°,955 Signature= � �_ MY COMM!,"! ,•24.2024 F,4 u�'.AN'0Y8ENMY eY POGLIC-STATE OF IDAHO 2'H5S10NNUMBER 201809U ``0,,+13810N EXPIRES 5-24.2024 EXHIBIT " A" LOT 9 OF BLOCK 39 OF SANTA CARMELI7A UNIT NO. 3, IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, AS SHOWN SY NEAP ON FILE IN BOOK 18, PAGE 59 OF NEAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY. 'END OF LEGAL DESCRIPTION' BUILDING ENERGY ANALYSIS REPORT I D�J PROJECT: Plan 2.086 52085 Avenida Cortez - APN.: 774-201-017 La Quinta, Ca 92253 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE / .ATE ��+I, t �Y -c Project Designer: Santiago Lopez Ocampo P.O. Box 1018 La Quinta, Ca 92247 760.485.8927 2,6 1 q - 00 r�s Report Prepared by: SLO Santiago Lopez-Ocampo P.O. Box 1018 La Quinta, Ca 92247 760.485.8927 RECEIVED � Job Number: AR 19 2019 LQ020119 CITY OF LA R EC E IVEL-COMMUNITYDE Date: MAR 21 2019 *'� 3/10/2019 INTERWEST CONSULTING GROUP The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft com. I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF-1 R-PRF-01-E Certificate of Compliance 3 Form RMS-1 Residential Measures Summary 12 Form MF-1 R Mandatory Measures Summary 14 HVAC System Heating and Cooling Loads Summary 18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2.086 Calculation Date/Time: 12:39, Sun, Mar 10, 2019 CFI R-PRF-01 , Page I of 9 Calculation Description: Title 24 Analysis Input File Name: 52085 AVENIDA CORTEZ.ribd16x GENERAL INFORMATION 01 Project Name Plan 2.086 02 Calculation Description Title 24 Analysis 03 Project Location 52085 Avenida Cortez - APN.: 774-201-017 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 90 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft) 2086 15 Number of Zones 1 16 Slab Area (ft2) 2086 17 Number of Stories 1 18 Addition Cond. Floor Area(ft2) n/a 19 Natural Gas Available No 20 Addition Slab Area (ft2)1 n/a 21 Glazing Percentage (%) 27.7% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 0.62 3.87 -3.25 -524.2% Space Cooling 86.37 77.93 8.44 9.8% IAQ Ventilation 1.12 1.12 0.00 0.0% Water Heating 11.92 1029 1.63 13.7% Photovoltaic Offset — 0.00 0.00 ---- Compliance Energy Total 100.03 93.21 6.82 6 8% Registration Number: 219-P010053059C-000-000-0000000-0000 Registration DatelTime: 2019-03-10 12:42:09 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-03-10 12:40:46 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Plan 2.086 Calculation Description: Title 24 Analysis Calculation Date/Time: 12:39, Sun, Mar 10, 2019 Input File Name: 52085 AVENIDA CORTEZ.ribd16x Page 2 of 9 ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR 52.4 49.8 0.0 49.8 ❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. ❑ Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified. Notes: • Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Window overhangs and/or fins • Exposed slab floor in conditioned zone HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis Additional detail is provided in the building components tables below. Building -level Verifications: • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: • -- None -- Registration Number: 219-P010053059C-000-000-0000000-0000 Registration Date/Time: 2019-03-10 12:42:09 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-03-10 12:40:46 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2.086 Calculation Date/Time: 12:39, Sun, Mar 10, 2019 CF1 R-PRF-01 Page 3 of 9 Calculation Description: Title 24 Analysis Input File Name: 52085 AVENIDA CORTEZ.ribdl6x BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ftZ) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Plan 2.086 2086 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ftZ) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Whole House Conditioned HVAC System1 2086 10 DHW Sys 1 n/a OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ftZ) Window & Door Area (ft) Tilt (deg) Fr/E Whole House R-21 Wall w/1 EPS 90 Front 191.6 130.596 90 Le/S Whole House R-21 Wall w/1 EPS 180 Left 760 122.5 90 Re/W Whole House R-21 Wall w/1 EPS 270 Back 400 234.45 90 Ri/N Whole House R-21 Wall w/1 EPS 0 Right 600 83 90 Interior Surface Whole House R-21 Wall Interior n/a n/a 321.25 21.3 n/a Roof 2 Whole House R-38 Roof Attic RB + GAFG n/a n/a 2079 n/a n/a OPAQUE SURFACES — Cathedral Ceilings 01 02 03 04 05 06 07 08 09 10 Name Zone Type Orientation Area (ft) Skylight Area (ft2) Roof Rise (x in 12) Roof Reflectance Roof Emittance Cool Roof Roof Whole House R-38 Roof Attic RB + GAFG1 Right 7.1 7 0.2 1 0.67 0.88 Yes ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Whole House Attic RoofWhole House Ventilated 0.2 0.67 088 Yes Yes Registration Number: 219-P010053059C-000-000-0000000-0000 Registration Date/Time: 2019-03-10 12:42:09 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-03-10 12:40:46 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2.086 Calculation Date/Time: 12:39, Sun, Mar 10, 2019 CF1 R-PRF-01 Page 4 of 9 Calculation Description: Title 24 Analysis Input File Name: 52085 AVENIDA CORTEZ.ribd16x FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft) U-factor SHGC Exterior Shading 3080 FrDr Entry Window Fr/E (Front-90) 3.0 8.0 1 24.0 0.36 0.35 Insect Screen (default) 1980 Entry Sidelite Window Fr/E (Front-90) 1.8 8.0 1 14.0 0.28 0.22 Insect Screen (default) 4916 Entry Transom Window Fr/E (Front-90) 4.8 1.5 0.996 7.1 0.28 0.22 Insect Screen (default) 9080 SGD Dining Window Fr/E (Front-90) 9.0 8.0 1 72.0 0.47 0.24 Insect Screen (default) 9016 Fix Dining Window Fr/E (Front-90) 9.0 1.5 1 13.5 0.28 0.22 Insect Screen (default) 4040 Dining Transom Window Le/S (Left-180) ---- - 1 16.0 028 0.25 Insect Screen (default) 3030 Living Transom Window Le/S (Left-180) 1 9.0 028 0.25 Insect Screen (default) 3030 Living Transom 2 Window Le/S (Left-180) ---- 1 9.0 0.28 025 Insect Screen (default) 9080 SGD MBed Window Le/S (Left-180) 9.0 8.0 1 72.0 0.47 0.24 Insect Screen (default) 2960 MBed Window Le/S (Left-180) 2.8 60 1 16.5 028 0.25 Insect Screen (default) 14080 SGD Dining/Kitchen Window Re/W (Back-270) 14.0 80 1 112.0 0-47 0.24 Insect Screen (default) 61016 Living Transom Window Re/W (Back-270) 6.8 1.5 1 10.2 0.28 0.22 Insect Screen (default) 61016 Living Transom 2 Window Re/W (Back-270) 6.8 1.5 1 10.2 0.28 0.22 Insect Screen (default) 3860 MBed Window Re/W (Back-270) 3.7 6.0 1 22.0 0.28 0.25 Insect Screen (default) 10080 SGD MBed Window Re/W (Back-270) 10.0 8.0 1 80.0 0.47 0.24 Insect Screen (default) 4016 Master Bath Window RUN (Right-0) ---- - 1 6.0 0.28 0.25 Insect Screen (default) 5050 Bed2 Window RUN (Right-0) - 1 25.0 0.30 0.22 Insect Screen (default) 5016 Bed2 Transom Window Ri/N (Right-0) - - -- 1 7.5 0.28 0.25 Insect Screen (default) 4016 Bath 2 Window Ri/N (Right-0) ---- - 1 6.0 0.28 0.25 Insect Screen (default) 5050 Bed3 Window Ri/N (Right-0) -- - 1 25.0 0.30 022 Insect Screen (default) 5016 Bed3 Transom Window RUN (Right-0) -- 1 7.5 028 0.25 Insect Screen (default) 4016 Laundry Window Ri/N (Right-0) -- 1 6.0 0.28 0.25 Insect Screen (default) 10 Solatube Walk -In Clos Skylight Roof (Right-0) 1 .5 0.61 0.27 10 Solatube Bath3/Powder Skylight Roof (Right-0) 1 .5 0.61 0.27 2030 @ Kitchen Skylight Roof (Right-0) 1 6.0 042 1 0.32 Registration Number: 219-P010053059C-000-000-0000000-0000 Registration Date/Time: 2019-03-10 12:42:09 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-03-10 12:40:46 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2.086 Calculation Date/Time: 12:39, Sun, Mar 10, 2019 CF1 R-PRF-01 Page 5 of 9 Calculation Description: Title 24 Analysis Input File Name: 52085 AVENIDA CORTEZ.ribd16x OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 3080 FrDr Entry 4 2 1 1 0 0 0 0 0 0 0 0 0 1980 Entry Sidelite 4 2 1 1 0 0 0 0 0 0 0 0 0 4916 Entry Transom 4 0.1 4 4 0 0 0 0 0 0 0 0 0 9080 SGD Dining 4 2 1 1 0 0 0 0 0 0 0 0 0 9016 Fix Dining 4 01 4 4 0 0 0 0 0 0 0 0 0 9080 SGD MBed 4 2 1 1 0 0 0 0 0 0 0 0 0 2960 MBed 4 2 1 1 0 0 0 0 0 0 0 0 0 14080 SGD Dining/Kitchen 8 2 25 2.5 0 0 0 0 0 0 0 0 0 61016 Living Transom 8 0.1 8 8 0 0 0 0 0 0 0 0 0 61016 Living Transom 2 8 0.1 8 8 0 0 0 0 0 0 0 0 0 3860 MBed 4 2 J 1 1 0 0 0 0 0 0 0 0 0 10080 SGD MBed 4 2 1 1 1 0 0 0 0 0 0 0 0 0 Registration Number: 219-P010053059C-000-000-0000000-0000 Registration Date/Time: 2019-03-10 12:42:09 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-03-10 12:40:46 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2.086 Calculation Date/Time: 12:39, Sun, Mar 10, 2019 CF1 R-PRF-01 Page 6 of 9 Calculation Description: Title 24 Analysis Input File Name: 52085 AVENIDA CORTEZ.ribd16x OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck. Wood Siding/sheathing/decking Attic RoofWhole House Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Ca vity / Frame: R-21 / 2x6 R-21 Wall Interior Interior Walls Wood Framed Wall 2x6 @ 16 in. O C R 21 0 064 Other Side Finish: Gypsum Board Inside Finish: Gypsum Board Cavity/Frame: R-21 /2x6 Sheathing / Insulation. R5 Sheathing R-21 Wall w/1 EPS Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.048 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic RB + GAFG attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 Over Ceiling Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-38 / 2x4 Roof Deck: Wood Siding/sheathing/decking R-38 Roof Attic RB + GAFG1 Cathedral Ceilings Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.036 Roofing: Light Roof (Asphalt Shingle) SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Slab -on -Grade Whole House 2086 0.1 None 0 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Not Required Quality Installation of Spray Foam Insulation Not Required Building Envelope Air Leakage Not Required CFM50 n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Standard DHW Heater 1 (1) 1 .0% Registration Number: 219-P010053059C-000-000-0000000-0000 Registration DatelTime: 2019-03-10 12:42:09 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-03-10 12:40:46 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Plan 2.086 Calculation Description: Title 24 Analysis Calculation Date/Time: 12:39, Sun, Mar 10, 2019 Input File Name: 52085 AVENIDA CORTEZ.ribd16x Page 7 of 9 WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Input Rating / Tank Standby Heater Tank Uniform Energy Pilot / Insulation Loss / First Hour NEEA Heat Pump Tank Location Element Number Volume Factor / Energy Thermal R-value Recovery Rating / Brand / Model / or Ambient Name Type Tank Type of Units (gal) Factor / Efficiency Efficiency (Int/Ext) Eff Flow Rate Other Condition DHW Heater 1 Gas Small 1 0 0.95 EF <= 200 kBtu/hr R-0/R-0 0 n/a n/a n/a Instantaneous SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC Systeml Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Efficiency Heating Component 1 CntrlFurnace 1 96 AFUE HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Name System Type Number of Units Efficiency EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 SplitAirCond 1 13 I 16 F1-hers-cool Not Zonal Single Speed Cooling Component HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Specified Lower Leakage Target 8 Attic None Air Distribution System 1-hers-dist Registration Number: 219-P010053059C-000-000-0000000-0000 Registration Date/Time: 2019-03-10 12:42:09 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-03-10 12:40:46 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2.086 Calculation Date/Time: 12:39, Sun, Mar 10, 2019 CF1 R-PRF-01 Page 8 of 9 Calculation Description: Title 24 Analysis Input File Name: 52085 AVENIDA CORTEZ. ribd 1 6x HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required 5.0 Not Required Not Required Not Required Not Required Required HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 058 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 51 025 Default 0 Required Registration Number: 219-P010053059C-000-000-0000000-0000 Registration Date/Time: 2019-03-10 12:42:09 HERS Provider: CalCERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-03-10 12:40:46 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Plan 2.086 Calculation Date/Time: 12:39, Sun, Mar 10, 2019 CFI R-PRF-01 Page 9 of 9 Calculation Description: Title 24 Analysis Input File Name: 52085 AVENIDA CORTEZ.ribd16x DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signaturf-i Santiago Lopez-Ocampo Company: Signature Date: Santiago Lopez-Ocampo 2019-03-10 12:42:09 Address: CEA/HERS Certification Identification (If applicable): P.O. Box 1018 n/a City/State/Zip: Phone: La Quinta, CA 92247 760-485-8927 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature - Santiago Lopez-Ocampo Company: Date Signed: Santiago Lopez-Ocampo 2019-03-10 12:42:09 Address: License: P.O. Box 1018 n/a City/State/Zip: Phone: La Quinta, CA 92247 760-485-8927 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 219-P010053059C-000-000-0000000-0000 Registration Date/Time: 2019-03-10 12:42:09 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 sv to at HERS Provider: CaICERTS inc Report Generated at: 2019-03-10 12:40:46 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Plan 2.086 Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 311012019 Project Address California Energy Climate Zone 52085 Avenida Cortez - APN.: 774-201-01i CA Climate Zone 15 Total Cond. Floor Area 2,086 Addition n/a # of Units 1 INSULATION Construction Type Cavity Area ffz Special Features Status Slab Unheated Slab -on -Grade Demising Wood Framed - no insulation R 21 2,086 Perim = 0' 300 New New Wall Wood Framed R 21 1,381 Add=R-5.0 New Roof Wood Framed Attic R 38 2,079 Cool Roof New FENESTRATION Orientation Area(ft) I Total Area: 578Glazing Percentage: 27.7 % U-Fac SHGC Overhang Sidefins NewlAltered Avers a U-Factor; Exterior Shades 0.40 Status Front (E) 24.0 0.360 0.35 4.0 none Bug Screen New Front (E) 14.0 0.280 0.22 4.0 none Bug Screen New Front (E) 20.6 0.280 0.22 4.0 none Bug Screen New Front (E) 72.0 0.470 0.24 4.0 none Bug Screen New Left (S) 34.0 0,280 0.25 none none Bug Screen New Left (S) 72.0 0.470 0.24 4.0 none Bug Screen New Left (S) 16.5 0.280 0.25 4.0 none Bug Screen New Rear (VV) 112.0 0.470 0.24 8.0 none Bug Screen New Rear 20.5 0.280 0.22 8.0 none Bug Screen New Rear (VV) 22.0 0.280 0.25 4.0 none Bug Screen New Rear (VV) 80.0 0.470 0.24 4.0 none Bug Screen New Right (N) 33.0 0.280 0.25 none none Bug Screen New Right (N) 50.0 0.300 0.22 none none Bug Screen New Skylight 0.5 0.610 0.27 none none None New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 96 % AFUE Split Air Conditioner 16.0 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R-Value Status HVAC System Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Small Instantaneous Gas 0 0.95 Standard New EneravPro 7.2 by Ener vSoft User Number: 5732 ID: LQ020119 Paae 12 of 18 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name _Plan 2.086 Project Address 52085 Avenida Cortez - APN.: 774-201-01 Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 311012019 California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,08( Addition r # of Units 1 INSULATION Area Construction Type Cavity (ft) Special Features Status FENESTRATION I Total Area: 578 Glazing Percentage: 27.7 % New/Altered Average U-Factor: Orientation Area(ft) U-Fac SHGC Overhang Sidefins Exterior Shades 0.40 Status Skylight 0.5 0.610 0.27 none none None New Skylight 60 0.420 0.32 none none None New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status -EnergyPro 7.2 by EnergySoft User Number. 5732 ID: LQ020119 Pa a 13 of 18 Ainm JL 2016 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. "Exceptions may apply. (Revised 04/2017) Building Envelope Measures: § 110.6(a)1: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft2 or less when tested per NFRC-400 orASTM E283 orAAMA/WDMA/CSA 101/I.S.2/A440-2011.' § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES 110.6-A and 110.E-B for compliance and must be caulked and/or weatherstri ed. ` § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i) Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 11 0.8i when the installation of a cool roof is specified on the CF1 R. § 110.8(j): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043. Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling.' § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Above Grade Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U- § 150.0(c): factor of 0.074 or less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly.* § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.' § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 11 0.8. § 150.0(g)1: Vapor Retarder. In Climate Zones 1-16, the earth floor of unventetl crawl space must be covered with a Class I or Class II vapor retarder. This requirement also a2plies to controlled ventilation crawls ace for buildings complying with the exception to § 150.0(d). § 150.0(g)2: Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all insulation in all exterior walls, vented attics, and unventetl attics with air -permeable insulation. 150.0 § (q)' Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)1A: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)l B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readIly accessible, operable, and tight -fitting damper or combustion -air control device.' § 150.0(e)1 C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0-§ 110.1 Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the Energy Commission.` § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating.` § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat.' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110.3 C 5. § 110.3(c)7: Isolatlon Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs or otherfittin s on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed. § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- ances without an electrical supply voltage connection with pilot li hts that consume less than 150 Btu/hr are exempt); and pool and spa heaters.' Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)1: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J using design conditions s ecified in § 150.0 h 2. a 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any dryer vent. § 150.0(h)3B: Liquid Line Drier, Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's instructions. § 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures.` § 150.00)2B: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve.' § 150.00)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution piping for steam and hydronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the material. § 150.00)3B: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class 11 vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)1: 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btulhr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation SRCC) or by a listing agency that is approved by the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)1 (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts.' Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such toe is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustlon inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier, Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)l l: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through Feld verification and diagnostic testing, in accordance with § 150.0(m)11 and Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure drop, and labeling requirements of 150.0 m 12. 2016 Low -Rise Residential Mandatory Measures Summary Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow z 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central forced air systems." Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(o): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of rovidin whole -building ventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.* § 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines or built-in or built-up_connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods, § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. § 150.0(p): Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves.' Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9.' § 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must be certified to the Energy Commission according to Reference Joint Appendix JA8. § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B. other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan speed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1 C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C. A JA8-2016-E light source rated for elevated temperature must be installed by final Inspection in all recessed dowel' ht luminaires in ceilings. § 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)1 F: _ Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable Tguirements of § 150.0(k),* Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1 G: with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix JA8.' § 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E." § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with 150.0 k . § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4: meets the EMCS requirements of § 130.5 : and meets all other requirements in § 150.0 k 2. Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5. ' and all other requirements in § 150. k 2. § 150.0(k)21 Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it provides the functionality of a dimmeraccording to § 110.9, and complies with all otherapplicable requirements in § 150.0(k)2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancysensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.* § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMCS). Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either § 150.0(k)3A or with the ap Iicable requirements in 110.9, 130.0. 130.2. 130.4. 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0 k 3B or § 150.0 k 3D must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of power as determined according to § 130.0(c). § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential ga2ges in §§ 110.9, 130.0, 130.1. 130.4. 140.6, and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1 application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the requirements of § 110.10(b) through 4110.10(e). § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1: greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.` § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment." Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)36: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane.' § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through 110.1 0c must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and permanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Plan 2.086 JI 3/10/2019 System Name Floor Area HVAC System 2,086 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,303 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. Sensible Latent CFM 26,722 2,501 483 0 1,543 0 0 0 0 0 1,543 1 29,807 2,501 PEAK Heating System Sensible Output per System 80,000 18,800 Total Output Btuh) 80,000 Output Btuh/s ft 38.4 924 Coolino System 0 Output per System 52,500 0 Total Output (Btuh 52,500 0 Total Output (Tons) 4.4 924 Total Output (Btuh/s ft) 25.2 Total Output s ft/Ton 476.8 20,647 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2.000 Day & Night NXA660GKA" 35,359 9,150 80,000 80,000 Jan 1 AM Airflow (cfm/s ft) 0-96 Airflow(cfm/Ton 457.1 Outside Air % 0•0 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 35,359 9,150 Aug 3 PM Outside Air cfrn/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF 105 OF 105 OF Outside Air 0 cfm Heating Coil Supply Fan 2,000 cfm 105 OF ROOM 68 OF 68 OF �I11� COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 76/62OF 55/54OF 55/54OF i o 011 i Outside Air I. 0 cfm Cooling Coil Supply Fan 56 / 54 OF 2.000 cfm 47.5 % ROOM Jn 76 / 62 OF 75 / 62 OF