Loading...
BRES2019-0155-X 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type/Subtype: Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: LENCH DESIGN STUDIO INC PO BOX 450 LA QUINTA, CA 92253 Tity,, 4 4v Qu,6t& DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT BUILDING RESIDENTIAL/ADDITION BRES2019-0155 54850 RIVIERA 775031032 SHEARD / CASITA ADDIT 1) 0 $100,000.00 JUL 10 2019 CITY OF LA QUINTA DESIGN & DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B p License No.: 4043 ~� Contract r: w- J Ct_ OWNER-BUILDE DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address:_ VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 7/10/2019 Owner: GEORGESHEARD 54850 RIVIERA LA QUINTA, CA 92253 Contractor: LARRY COIA JR DBA 7 C'S CONSTRUCTION & M 48-236 VISTA DE NOPAL LA QUINTA, CA 92253 (760)564-5811 Llc. No.: 594043 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the rk For which this permit is issued. have and will maintain workers' compensation insurance, as required by S o of the Labor Code, For the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: WESCO INSURANCE COMPANY Policy Number: WWC3401054 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Sectio of the Labor Code, I shall forthwith comply with those provisions. 1`V ` Applicant; WARNING: FAILURE TO SECURE WORKERS' OMP SATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordin nd state laws relating to building construction, and hereby authorize represen ives this city to enter upon the above -mentioned property for inspection rpa n Date: ,� �� Signature (Appi cant or Age Date: 7/10/2 J('19 Application Number: BRES2019-0155 Property Address: 54850 RIVIERA APN: 775031032 Application Description: SHEARD / CASITA ADDITION Property Zoning: Application Valuation: $100,000.00 Applicant: LENCH DESIGN STUDIO INC PO BOX 450 LA QUINTA, CA 92253 Owner: GEORGESHEARD 54850 RIVIERA LA QUINTA, CA 92253 Contractor: LARRY COIA JR DBA 7 C'S CONSTRUCTION & M 48-236 VISTA DE NOPAL LA QUINTA, CA 92253 (760)564-5811 LIc. No.: 594043 Detail: 328 SF ATTACHED CASITA ADDITION WITH 10 LF OF CITY STANDARD EQUIPMENT SCREENING WALL [FRED SHEU ENGINEERING]. THIS INCLUDES INSTALLATION OF NEW MIN -SPLIT UNIT, PLUMBING, ELECTRICAL, AND FENESTRATION. 2016 CALIFORNIA BUILDING CODES. FINANCIAL INFORMATION DESCRIPTION ACCOUNT CITY AMOUNT ADDITION, EA ADDITIONAL 500 SF 101-0000-42400 0 $68.84 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $19.21 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, FIRST 100 SF 101-0000-42400 0 $134.48 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, FIRST 100 SF PC 101-0000-42600 0 $188.92 I Total Paid for ADDITION: $411.45 DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $4.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $4.00 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES, FIRST 20 101-0000-42403 0 $26.68 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES, FIRST 20 PC 101-0000-42600 0 $26.68 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES/FIXTURES, ADDITIONAL 101-0000-42403 0 $56.07 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES/FIXTURES, ADDITIONAL PC 101-0000-42600 0 $14.07 DESCRIPTION ACCOUNT QTY AMOUNT OTHER ELECTRICAL EQUIPMENT 101-0000-42403 0 $26.68 DESCRIPTION ACCOUNT QTY AMOUNT OTHER ELECTRICAL EQUIPMENT PC 101-0000-42600 0 $26.68 Total Paid for ELECTRICAL: $176.86 DESCRIPTION ACCOUNT QTY AMOUNT 101-0000-42600 ($12.94) DESCRIPTION ACCOUNT QTY AMOUNT 101-0000-42600 ($5.34) DESCRIPTION ACCOUNT QTY AMOUNT AIR HANDLER 101-0000-42402 0 $40.02 DESCRIPTION ACCOUNT QTY AMOUNT AIR HANDLER PC 101-0000-42600 0 $13.34 DESCRIPTION ACCOUNT QTY AMOUNT CONDENSER/COMPRESSOR 101-0000-42402 0 $40.02 DESCRIPTION ACCOUNT QTY AMOUNT CONDENSER/COMPRESSOR PC 101-0000-42600 0 $26.68 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN 101-0000-42402 0 $12.94 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN 101-0000-42402 0 $0.40 ' DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN PC 101-0000-42600 0 $5.34 Total Paid for MECHANICAL: $120.46 DESCRIPTION ACCOUNT QTY AMOUNT PLAN CHECK DEPOSIT - ADDITION/REMODEL 101-0000-42600 1 $125.00 Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $125.00 DESCRIPTION ACCOUNT QTY AMOUNT 101-0000-42600 ($40.02) DESCRIPTION ACCOUNT QTY AMOUNT 101-0000-42600 ($40.02) DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($13.34) DESCRIPTION ACCOUNT QTY AMOUNT 101-0000-42600 ($13.34) DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $40.02 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $40.02 DESCRIPTION ACCOUNT CITY AMOUNT WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $13.34 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $13.34 Total Paid for PLUMBING FEES: $0.00 DESCRIPTION ACCOUNT CITY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $13.00 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $13.00 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 a (V Qul�fra Project Address: ItLV-A APN #: 77,5�- ©:;5I, 03Z. Project Description: Ac,--C�*,DC -al S CA-�rT-4, Applicant Name:#-�C-��1`� c7 i Address: �C3 -���� 44;!Z:-d City, ST, Zip: 6A�,U—�/l C7z Telephone: _ 570 -57 Email: C �GCa�� CaDo� Valuation of Project 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 OFFICE USE ONLY # I Submittal 1 Required I Received Plan Sets Structural Calcs Truss Calcs Title 24 Calcs Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License Date:7/10/2019 No.: 19-01403-1 Owner: George Sheard Address: 54-850 Riviera City: La Quinta Type: Detached Guest House Lot # Street No. 54-850 Comments: CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760)771-8515 Email: Jurisdiction: La Quinta Tract #: Street Name Sq. Feet APN Riviera 328 775-031-032 Casita �R�AHf{H;} � UuxC. 1i r NVLI}A,���titGt�.� lAUUIPt=R �. y� Permit No. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement mobile homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fess imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $3.79 X 328 S.F. or $1,243.12 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued. Fees Paid By: CCIRabobank Larry Coia Check No.: 8007378 Bank Name/Recipient of Certificate Telephone: 760-831-5212 Funding: Residential By Scott L. Bailey Superintendent Fee Collected/ Exempted by: Arianne Catano Certificate Fees Due: $1,243.12 • Original Payment(s) Rec'd: $0.00 New Payment Rec'd: $1,243.12 Over/Under: $0.00 NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you ;may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL. June 28, 2019 To whom it may concern, I, George Sheard, the owner of 54850 Riviera in La Quinta have secured the services of 7 C's construction (Larry Coia) to construct to completion a Casitta on my property and attached to rrw hot�4. I C� 204-573-4443 Building Permit Number: ' f�. • . Project Description: small addition/casita .,} Exempt: ❑ (Materials may contain hazardous wastes and are not subject to recycling provisions) OF 1A Construction Debris Management Plan Plan Submittal Date I 7/5/2019 Job Site Address 54850 Riviera Ln Owners Name Geroge Sheard Number, Street, or PO Box 54850 Riviera Ln City, State, Postal Code La Quints, CA. 92253 Owners Phone Number c% 760-831-5212 Owners E-mail Address Project Managers Name Larry Cois Project Managers Phone Number 760-831-5212 Project Managers E-mail Address 7nstrusgndc.rrcom Builder / Contractor 7 C'S Construction Number, Street or PO Box 48236 Vista De Nopal City, State, Postal Code La Quints, CA. 92253 Project Square Footage i Approx. 328 sf City Approval By Renado GoukHodc-0EC/Burrtec Wes] 1 Date of City Approval O ` lc) Materials To Be Discarded: Product Trash Asphalt Brick/Block Cardboard Commingled Concrete Drywall Donated / Reuse" Tons 1201 Not recyclable 0.00 Recyclable 0.00 Recyclable 0.00 Recyclable 1.16 Recyclable 0.16 Recyclable 0.00 Recyclable "Describe Items C Totals: Recycle Trash = 2—.3] 1.2 Product Tons Masonry (broken) 0.00 Plaster 0.37 Scrap Metal 0.00 Tile (floor) 0.03 Tile (roof) 0.04 Wood 0.57 Landscape Debris 0.00 Projected Diversion_ S6.01% I understand It is the property owners responsibility to submit copies of weight tickets or receipts to the Dlsbict Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued in the name of the property owners) and shall remain their property throughout the construction and/or demolition project A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through bi-monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer Owner / Developer / Project Manager / Superintendent Date I BUILDING ENERGY ANALYSIS REPORT PROJECT: Sheard Residence 54-850 Riviera La Quinta, CA 92254 Project Designer: Lench Design Studio, Inc. P.O. Box 450 La Quinta, Ca 92253 Report Prepared by: Joan Hacker Insu-form, Inc. 43585 Monterey Avenue, Suite 7 Palm Desert, Ca 92260 760-345-1352 CITY OF LA QUANTA BUILDING DIVISION REVIEVV,�D FOR CODE COMPLIANCE Joe Number RECEIVED Date: MAY 1 � 2019 CITY OP LA QUINTA 5/13/2019 DESIGN AND DEVELOPMENT DEPARTMENT The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software —www.energysoft.com. �:o I TABLE OF CONTENTS I Cover Page Table of Contents Form CF-1 R-PRF-01-E Certificate of Compliance 2 3 Form RMS-1 Residential Measures Summary 12 Form MF-1 R Mandatory Measures Summary 14 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fern Detached Calculation Date/Time: 15:28. Mon, May 13, 2019 Calculation Description: Title 24 Analysis Input File Name: Sheard Existing Addition.ribdl6x CF1R-PRF-01 Pagel of 9 GENERAL INFORMATION 01 Project Name Single Fam Detached 02 Calculation Description Title 24 Analysis 03 Project Location 54-850 Riviera 04 City La Quints 05 Standards Version Compliance 2017 06 Zip Code 92254 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 09 Software Version Energy Pro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 90 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (112) 3698 15 I Number of Zones 2 16 Slab Area (ft2) 3698 17 Number of Stories 1 18 Addition Cond. Floor Area (ftZ) 328 19 Natural Gas Available Yes 20 Addition Slab Area (ftZ) 328 21 1 Glazing Percentage (%) 13.7 % COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification 03 This building Incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 681 6.87 -0 06 -0 9 % Space Cooling 210.31 208,51 1.80 0.9 % IAQ Ventilation 000 0.00 0.00 0.0 % Water Heating 6.30 6.30 0.00 1 0.0 % Photovoltaic Offset — 0.00 0.00 --- Compliance Energy Total 223.42 221.68 1.74 0.8 % REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. Window overhangs and/or fins Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 HERS Provider: Report Generated at: 2019-05-13 15:28:52 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Single Fam Detached Calculation Date/Time: 15:28, Mon, May 13, 2019 Page 2 of 9 Calculation Description: Title 24 Analysis Input File Name: Sheard Existing Addition.ribdl6x HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: -None-- Cooling System Verifications: ..None -- HVAC Distribution System Verifications: ..None -- Domestic Hot Water System Verifications: .-None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ftZ) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Single Fam Detached 3698 1 4 2 0 1 ZONE INFORMATION 01 02 03 04 06 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg, Ceiling Height Water Heating System 1 Water Heating System 2 Existing Living Conditioned Living Zonal 3370 9 DHW Sys 1 n/a Addition Conditioned Addilion2 328 9 DHW Sys 1 n/a Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06232018-1149 Report Generated at: 2019-05-13 15:28: 52 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 15:28, Mon, May 13, 2019 Calculation Description: Title 24 Analysis Input File Name: Sheard Existing Addition-ribdl6x CF1R-PRF-01 Page 3 of 9 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 11 Name Zone Construction Azimuth Orientation Gross Area (ft) Window & Door Area (ft2) Tilt (deg) Wall Exception Status Verified Existing Condition Front Wall Existing Living Default Wall 1978 to 1991 90 Front 600 75.5 90 n/a Existing No Left Wall Existing Living Default Wall 1978 to 1991 180 Left 800 46 90 n/a Existing No Rear Wall Existing Living Default Wall 1978 to 1991 270 Back 1000 240 90 n/a Existing No Right Wall Existing Living Default Wall 1978 to 1991 0 Right 1000 86.7 90 n/a Existing No Interior Surface Existing Living R-13 Wall 1 0 n/a Existing No Roof Existing Living Default Roof 197E to Pres 3370 n/a Existing No Front Wall 3 Addition R-15 Wall 90 Front 100 24 90 Extension New n/a Left Wall 2 Addition R-15 Wall 180 Left 1 0 90 Extension New n/a Rear Wall 2 Addition R-15 Wall 270 Back 1 0 90 Extension New n/a Right Wall 2 Addition R-15 Wall 45 315 120 6 90 Extension New n/a Front Wall 2 Addition R-15 Wall 135 45 80 29 90 Extension New n/a Roof 2 Addition R-38 Roof Attic 328 n/a New n/a ATTIC 01 02 03 04 06 06 07 08 09 10 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condition Attic Existing Living Attic RoofExisting Living Ventilated 0 0.1 0.85 No No Existing No Attic Addition Attic RoofAddition Ventilated 0 0.1 0.85 Yes No New No Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-0623201E-1149 HERS Provider: Report Generated at: 2019-05-13 15:28:52 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fern Detached Calculation Date/Time: 15:28, Mon, May 13, 2019 Calculation Description: Title 24 Analysis Input File Name: Sheard Existing Addition.ribd16x CF1 R-PRF-01 Page 4 of 9 FENESTRATION I GLAZING 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft2) U-factor SHGC Exterior Shading Status Verified Existing Condition Window Front Wall (Front-90) 6.0 8.0 1 46.0 0.71 0.73 Insect Screen (default) Existing No Window 2 Front Wall (Front-90) 4 0 5.0 1 20.0 0.71 0.73 Insect Screen (default) Existing No Window 3 Front Wall (Front-90) 2.5 3.0 1 7.5 0.71 0.73 Insect Screen (default) Existing No Window 4 Left Wall (Left-180) 20 3.0 1 6.0 0.71 0,73 Insect Screen (default) Existing No Window 5 Left Wall (Left-180) 4.0 5.0 1 200 0.71 0.73 Insect Screen (default) Existing No Window 6 Left Wall (Left-180) 40 5.0 1 20.0 0.71 0.73 Insect Screen (default) Existing No Window 7 Rear Wall (Back-270) 10.0 80 1 80.0 0.71 0.73 Insect Screen (default) Existing No Window 8 Rear Wall (Back-270) 100 8.0 1 80.0 0.71 0.73 Insect Screen (default) Exisling No Window 9 Rear Wall (Back-270) 10.0 80 1 80.0 0.71 0.73 Insect Screen (default) Existing No Window 10 Right Wall (Right-0) 4 0 5.0 1 1 200 0.71 0,73 Insect Screen (default) Existing No Window 11 Right Wall (Right-0) 30 5.0 1 15.0 0.71 0.73 Insect Screen (default) Existing No Window 12 Right Wall (Right-0) 30 5.0 1 15.0 0.71 073 Insect Screen (default) Existing No Window 13 Right Wall (Right-0) 5.0 5.0 1 25.0 0.71 0.73 Insect Screen (default) Existing No Window 14 Right Wall (Right-0) 24 50 0.975 11.7 0.40 0.26 Insect Screen (default) New n/a Window 15 Front Wall 3 (Front-90) 30 8.0 1 24.0 0.40 0.26 Insect Screen (default) New n/a Window 16 Right Wall 2 (- specify --45) 40 1.5 1 6.0 0.40 0.26 Insect Screen (default) New We Window 17 Front Wall 2 (- specify -135) 4.0 50 1 20.0 0.40 0.26 Insect Screen (default) New n/a Window 18 Front Wall 2 (- specify -135) 30 1 5 1 4.5 0.40 0.26 Insect Screen (default) New n/a Window 19 Front Wall 2 (- specify --135) 3.0 1.5 1 4.5 0.40 1 0.26 Insect Screen (default) New n/a Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06232018-1149 HERS Provider: Report Generated at: 2019-05-13 15:26:52 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Single Fam Detached Calculation Date/Time: 15:28, Mon, May 13, 2019 Page 5 of 9 Calculation Description: Title 24 Analysis Input File Name: Sheard Existing Addition.ribdl6x OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up Window 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 2 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 3 2 01 2 2 0 0 0 0 0 0 0 0 0 Window 4 2 01 2 2 0 0 0 0 0 0 0 0 0 Window 5 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 6 2 01 2 2 0 0 0 0 0 0 0 0 0 Window 7 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 8 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Wndow9 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 10 2 01 2 2 0 0 0 0 0 0 D 0 0 Window 11 2 0.1 2 2 0 0 0 0 0 0 0 0 D Window 12 2 01 2 2 0 0 0 0 0 0 0 0 0 Window 13 2 01 2 2 0 0 0 0 0 0 0 0 0 Window 14 2 01 2 2 0 0 0 0 0 0 0 0 0 Window 15 2 0.1 2 2 0 0 D 0 0 0 0 0 0 Window 16 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 17 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Wndow 16 2 0.1 2 2 0 0 0 0 0 0 1 0 0 0 Window 19 2 0.1 2 2 0 0 0 0 0 0 0 1 0 0 Registration Number: Registration Dale/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06232018-1149 Report Generated at: 2019-05-13 15:28:52 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 15:28, Mon, May 13, 2019 Calculation Description: Title 24 Analysis Input File Name: Sheard Existing Addition.ribdl6x CF1R-PRF-01 Page 6 of 9 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 06 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofExisting Living Attic Roofs Wood Framed Ceiling in, D.C. none 0 644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: R- 11 / 2x4 Default Wall 1978 to 1991 Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 11 0.110 Exterior Finish: 3 Coal Stucco • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9 1 /2x4 Default Roof 1978 to Pres attic) Wood Framed Ceiling 2x4 16 in. 0. C. R 19 0.049 Over Ceiling Joists: R-9 9 insut • Inside Finish: Gypsum Board • Cavity/Frame: R-13/2x4 R-13 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.092 Other Side Finish: Gypsum Board • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofAddition Attic Roofs Wood Framed Ceiling in, O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R-15/2x4 R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in, O.C. R 15 0.095 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9 1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 Over Ceiling Joists: R-26.9 insul SLAB FLOORS 01 02 03 04 05 06 07 08 09 Verified Perimeter Carpeted Existing Name Zone Area (ft) (ft) Edge Insul. R-value Fraction Heated Status Condition Covered Slab Existing Living 3370 989 None 1 No Existing No Slab -on -Grade Addition 328 195 None 1 No New No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required nia Registration Number: Registration DateMme: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 HERS Provider: Report Generated at 2019-05-13 15:28:52 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Single Fam Detached Calculation Date/Time: 15:28, Mon, May 13, 2019 Page 7 of 9 Calculation Description: Title 24 Analysis Input File Name: Sheard Existing Addition.ribdl6x WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) Verified Existing Status Condition DHW Sys 1 DHW Standard DHW Heater 1 1 0 Existing No WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Uniform Energy Factor I Energy Factor I Efficiency Input Rating / Pilot / Thermal Efficiency Tank Insulation R•value (Int/Ext) Standby Loss I Recovery Eff First Hour Rating / Flow Rate NEEA Heat Pump Brand / Model Tank Location or Ambient Condition DHW Heater 1 Gas Small Storage 1 50 0 6 EF <= 75 kBlulhr 0 n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Status Verified Existing Condition Living Zonel Other Heating and Cooling System Healing Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 Existing No Addition2 Heat Pump Heating and Cooling System Heat Pump System 2 Heat Pump System 2 None -none - New No HVAC - HEAT PUMPS 01 02 03 04 05 06 07 1 08 09 10 11 Name System Type Number of Units Heating HSPF/COP Cap 47 Cap 17 Cooling SEER EER Zonally Controlled Compressor Type HERS Verification Heat Pump System 2 RoomHeatPump 1 16.8 15000 10500 12 F17 Not Zonal Single Speed Heat Pump System 2-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 06 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Heat Pump System 2-hers-cool Not Required n/a Not Required Not Required Not Required Registration Number: Registration Dale/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-05-13 15:28: 52 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 15:28, Mon, May 13. 2019 Calculation Description: Title 24 Analysis Input File Name: Sheard Existing Addition.ribdl6x CF1 R-PRF-01 Page 8 of 9 HVAC- DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Name Type Duct Leakage Insulation R-value Supply Duct Location Return Duct Location Bypass Duct Status Verified Existing Condition HERS Verification Air Distribution System 1 Ducts located in attic (Ventilated and Unventilated) Existing (not specified) 8.0 Attic Attic None Existing No n/a IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ WattsICFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVenlRpl 0 0.25 Default 0 Not Required Registration Number: Registration DatelTime: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232016-1149 HERS Provider: Report Generated at: 2019-05-13 15:26:52 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Description: Title 24 Analysis Calculation Date/Time: 15:28, Mon, May 13, 2019 Input File Name: Sheard Existing Addition.ribdl6x DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete Documentation Author Name: Joan Hacker Company: Insu-form, Inc. Address. 43585 Monterey Avenue, Suite 7 City/Statezio Desert C~ �uv montQUon(AAuuthor Signature 7' r L rgnattlra Date: 5/13/2019 CEA/HERS Certification Identification (If applicable): CFI R-PRF-01 Page 9 of 9 Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT 760-345-1352 ! certify the fotldwing tlntlar penally pf perlyrry, Under the laws of [na Stale 4f Callfmrrla 1 I am eligible under Dlwsron 3 e the 9uslness and Argfas>ovns Coda Id secapt rosponsi..... for Iho twllding design Identified Ort this Cdrtificata of Compliance, 2 1 cerlrly Thal file aria f Regutabons. r4y salutes and p dmlance speprlCailons Identified on this Cerbrlcate v1 COmplrarwe Conform to the regulre s Ce(nis Of etcTill24, Part 1 and Part 6 of the California Code of 3. The building design faaWres Or system design fesiures Idehlifled on this Cenifirate Of Compliance gm Consistent Ih a Inform�tivn ro shoal9. GalCupailons, plans and.specaiica[ions subrnl![ad tdlhe enfWcefnenl agent for a�aoe Designer Name: Y PPro�al with fhls dl p on Utl r applicable compliance documents, . P. Lench II pormitapplicsC Responsibler r Srmnm ,. Company: Lench Design Studio, Inc. Address: P.O. Box 450 City/Slate/Zip: La Quinta, Ca 92253 Dat:01w6d• License Phone: Registration Number: CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: Report Version - CF1R-06232018-1149 HERS Provider: Report Generated at: 2019-05-13 15:28:52 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Sheard Residence Project Address 54-850 Riviera La Quinta Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration California Energy Climate Zone Total Cond. Floor Area Addition CA Climate Zone 15 3,698 328 Date 511312019 # of Units 1 INSULATION Construction Type Area Cavity ff Special Features Status Slab Unheated Slab -on -Grade no insulation 3,370 Perim = 989' Existing Wall Wood Framed R 11 525 Existing Wall Wood Framed R 11 754 Existing Wall Wood Framed R 11 760 Existing Wall Wood Framed R 11 913 Existing Roof Wood Framed Attic R 19 3,370 Existing Demising Wood Framed R 13 1 Existing Wall Wood Framed R 15 76 New FENESTRATION Orientation Area(fe) Total Area: 507 Glazing Percentage: 13.796 U-Fac SHGC Overhang Sidefins New/Altered Average U-Factor. Exterior Shades 0.40 Status Front (E) 75.5 Left (S) 46.0 0.710 0.710 0.73 2.0 none 0.73 2.0 none Bug Screen Bug Screen Existing Existing Rear (lM 240.0 0.710 0.73 2.0 none Bug Screen Existing Right (N) 75.0 0.710 0.73 2.0 none Bug Screen Existing Right (N) 11.7 0.400 0.26 2.0 none Bug Screen New Front (E) 24.0 0.400 0.26 2.0 none Bug Screen New Right (NE) 6.0 0.400 0.26 2.0 none Bug Screen New Front (SE) 29.0 0.400 0.26 2.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 78% AFUE Split Air Conditioner 12.0 SEER Setback Existing 1 Room Heat Pump 6.00 COP Room PTAC without Si( 13.0 EER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R-Value Status Living Zone Ducted Ducted Attic 8.0 Existing Addition Ductless / with Fan Ductless n/a n/a New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EneravPro 7.2 by EnerovSoft User Number.- 2655 ID: Paae 12 of 19 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Sheard Residence Project Address 54-850 Riviera La Quinta Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 511312019 California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 3,698 Addition 328 # of Units 1 INSULATION Construction Type Area Cavity W) Special Features Status Wall Wood Framed R 15 1 New Roof Wood Framed Attic R 38 328 New Wall Wood Framed R 15 1 New Wall Wood Framed R 15 114 New Slab Unheated Slab -on -Grade - no insulation 328 Perim = 195' New Wall Wood Framed R 15 51 New FENESTRATION Orientation Area(fiz) I Total Area: 507 Glazing Perceni.a e: 13.7% New/Altered Average 11-Factor: a 40 U-Fac SHGC Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Enere Pro 7 2 by EnerqySoft User Number: 2655 ID. Pa a 1�,fI9 2016 Low -Rise Residential Mandatory Measures Summary NOTE; Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used Review the respective section for more information. 'Exceptions may apply. (Revised 0412017/ Building Envelope Measures: § 110.6(a)1: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ftz or less when tested per NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-2011.' § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES _ 110.6-A and 110.E-13 for compliance and must be caulked and/or weatherstripped.' § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i), Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 11 0,8i when the installation of a cool roof is specified on the CF1 R. § 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043. Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 1103, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling.' § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Above Grade Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U- § 150.0(c): factor of 0,074 or less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly.' § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0,037 maximum U-factor.' § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8 . § 150.0(g)1: Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This requirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 1 50.0d . § 150.0(g)2: Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all insulation in all exterior walls, vented attics, and unvented attics with air -permeable Insulation. § 150.0 (q)' Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-factar of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)1A: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)1 B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight-fittingtight-ritting damper or combustion -air control device.' § 150.0(e)l C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control' § 150.0(e)2.- Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a fireboxjacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110,0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the Energy Commission.' § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is hi her than the cut-off temperature for sup lementar heatin .' § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat.' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 11age) 5. § 110 3(c)7; Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTUfhr (2 kW) trust have isolation valves with hose bibbs or other fittin s on both cold water and hot water Imes of water healing systems to allow for water tank flu shin when Ilse valves are closed. § 110.5: Pilot lights. Continuously burning pilol lights are prohibited For nalural gas: fan -type central furnaces; household cooking appliances (appfi- ances withoul an electrical supply voltage connection with p1lat II his that consume less than 150 Nutt are exem t ; and pool and spa healers,' Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)1: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J using design conditions specified in § 1 50.0h 2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any dryer vent. § 150,0(h)3B: Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's instructions. § 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. Water piping and cooling system line insulation, For domestic hot water system piping, whether buried or unburied, all of the following must he insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150,00)2A: nominal diameter of 314 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and ail hot water pipes from the heating source to kitchen fixtures.' § 150,00)2B: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve' § 150.00)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution 010ing for steam and h dronic heating systems or hot waters ems must meet the requirements in TABLE 120.3-A.' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover, The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the.material. § 150.00)3B: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class 1 or Class I I vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following77-7 a § 150.0(n)1; 120V electrical receptacle within 3 feet of the water heater; a Category Ill or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a as suppI line with a capacity of at least 2M.000 Btu/hr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5, § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation SRCC or by a listing agency that is approved by the Fxecutive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC), If a contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0. 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605,0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)1: (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than''/a inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts.' Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tam unless Such la is.Used in combination with mastic and draw bands, § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction. § 150,0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150,0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manual) operated dampers in all nin s to the outside, except combustion inlet and outlet air o eri)n s and elevator shaft vents, Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover, Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation: § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioring systems use forced air duct systems to supply conditioned air to an § 150.0(m)l1: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance vvilli 150.0 m 11 and Reference ResiclenqgApiwdix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a. thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, ressure drop, and labeling requirements of § 150.0 m 12. Apath ZO 2016 Low -Rise Residential Mandatory Measures Summary Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system imust also demonstrate airflow z 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy s 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central forced airs stems.' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(o): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing whole -building ventilation. § 150.00)1A: field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testing, in accordance with Relerence Residential Appendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heatin .' § 110.4(b)1; Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover, § 110.4(b)3: Qlrectional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all purnps to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. § 150.0(p): Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping. filters, and valves.' Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of§ 110.9.' § 110.9(e): JAB High Efficacy Light Sources. To qualify as a JAB high efficacy light source for compliance with § 150.0(k), a residential light source must be certified to the Energy Commission according to Reference Joint Appendix JAB. § 150.0(k)1 A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes, The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B; other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fanspeed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1 C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilin s. § 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)1 F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of 150.0 k : Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1 G: with Reference Joint Appendix JAB. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix JA8.' § 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JAB compliant and must be marked with "JA8-2016-E." § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150,0(k)2G: functions as a dimmer according to § 110,9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 136 ; and meets all other requirements in § 150.0 k 2. Interior Switches and Controls. An FMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy Sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5 ; and all other requirements in S 150.0k 2. § 150.0(k)21: Interior Switches and Controls. A muftiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancy sensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.' § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or FMCS). Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either § 150.0 k 3A or with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0 k 3B or § 150.0(k)3D must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150,0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site must com Ily with the applicable requirements in §§ 110.9, 130.0, 130.2. 130.4, 140.7, and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of power as determined according to § 130.0(c). § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable re uirements for nonresidential garages in §§ 110.9. 130.0, 130.1, 130.4, 140.6, and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)613: i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of in ress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the requirements of § 110,10 b through § 110.10(e). § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110,10(b)1: greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any sk li ht area.' § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment.' Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice [lie § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical lane,' § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); and a pathway for routina of plumbing from the solar zone to the water -heating system. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10 c must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and 2ermanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Sheard Residence 5/13/2019 System Name Floor Area Living Zone 3,370 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL CFM Total Room Loads 6,998 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING Sensible 60,102 0 3.470 0 0 0 3,470 67,042 PEAK COIL HTG. Latent CFM 3,155 3,094 0 0 3,155 PEAK Heating System Sensible Output perSystem 56,000 73.356 Total Output Btuh 112,000 Output Btuh/s ft 33.2 3,605 Cooling System 0 Output perSystem 42,000 0 Total Output Btuh 84,000 0 Total Output Tons 7.0 3,605 Total Out ut Btuh/s ft 24.9 Total Output s ft/Ton 481.4 80,566 Air System CFM perSystem 2.210 HVAC EQUIPMENT SELECTION Airflow cfm 4,420 Existing 44,899 35.263 112,000 Airflow cfm/s ft 1.31 Total Adjusted System Output (Adjusted for Peak Design conditions) 1 TIME OF SYSTEM PEAK 112.000 Jan 1 AM Airflow cfm/Ton 631.4 44,899 35,263 Outside Air % 0.0% Outside Air (cfm/s ft) 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak 26 OF 69 OF 69 OF 93 OF O Outside Air - Ar- 0 cfm Supply Fan Heating Coil g eF 4,420 cfm ROOM 69 OF 70 W COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak) 112/78OF 79/69°F 79/69°F 69/66°F Outside Air Ar 0 cfm Supply Fan Cooling Coil 70166 " 1 4,420 cfm — 64.1% ROOM m_ 79/69°F __ 78160*F HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Sheard Residence System Name Addition Date 5/13/2019 Floor Area 328 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 157 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING Sensible 3,834 0 0 0 0 0 0 3,834 PEAK COIL HTG. Latent CFM 307 249 0 0 307 PEAK Heating System Sensible Output per System 15,000 9.281 Total Output Btuh 15,000 Output Btuh/s ft 45.7 a Cooling System Q Output per System 90,000 0 Total Output Btuh 90,000 0 Total Output Tons 7•5 0 Total Output Btuh/s ft 274.4 Total Output s fUTon 43.7 9,281 Air System CFM per System 300 HVAC EQUIPMENT SELECTION Airflow cfm 300 Mitsubishi Electronics MSH17NW 6,732 70,239 9,369 9.369 Jan 1 AM Airflow cfm/s ft 0.91 Airflow cfm/Ton 40.0 Total Adjusted System Output 6,732 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 70,2391 Aug 3 PM Outside Air % 0.0% Outside Air (cfm/s ft) 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak 26 OF 70 OF 70 IF 105 IF fn1 Outside Air 0 cfm Supply Fan Heating Coil 300 cfm 70 OF ( 41 105°F ROOM L ._ 70 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolin Peak) 112 / 78 IF 78 / 63 IF 78 / 63 OF 55 / 54 OF Outside Air Ar 0 cfm Supply I Fan Cooling Coil 300 cfm 78 / 63 IF flll� 55 / 54 IF 42.3% ROOM 78 / 63 OF '