Loading...
BSOL2019-00129 495 CALLE TAMPICO T-iht 4 VOICE (760) 777-7125 QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT - Date: 7/22/2019 Permit Type/Subtype: SOLAR/RESIDENTIAL LESS THAN 10KW Owner: Application Number: BSOL2019-0012 JOE & BERTIE BIRDSELL Property Address: 48751 SAN LUCAS ST 48751 SAN LUCAS APN: 658310002 LA QUINTA, CA 92253 Application Description: BIRDSELL / 4.88kW PV SYSTEM - (16) 305W PANELS W/ MICROINV. Property Zoning: Application Valuation: $15,800.00 Applicant: Contractor: PALM DESERT CONTRACTORS PALM DESERT CONTRACTORS P 0 BOX 2795 DP 0 BOX 2795 PALM DESERT, CA 92261 JUL 2 2 2019 PALM DESERT, CA 92261 (760) 636-8348 CITY OF LAQUINTA Llc. No.: 477507 DESIGN & DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 477507 Date: —7Contractor: OWNER-J KDECLARATION I hereby affirm under penalty ofperf6fy that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any 6 city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C, for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.), Lender's Name: Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: UgMPT Policy Number: _ @rtify that in the performance of the work for which this permit is issued, (shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date* �^ ZZr)� Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or fallowing issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above - mentioned property for inspection purposes. '�r23-mot i Date: Signature (Applicant or Agent , Date: T/22/204 Application Number: BSOL2019-0012 Owner: Property Address: 48751 SAN LUCAS ST JOE & BERTIE BIRDSELL APN: 658310002 48751 SAN LUCAS Application Description: BIRDSELL / 4.88kW PV SYSTEM - (16) 305W PANELS W/ MICROINV, LA QUINTA, CA 92253 Property Zoning: Application Valuation: $15,800.00 Applicant: Contractor: PALM DESERT CONTRACTORS PALM DESERT CONTRACTORS P 0 BOX 2795 P 0 BOX 2795 PALM DESERT, CA 92261 PALM DESERT, CA 92261 (760)636-8348 L)c- No-: 477507 ------------------------------------------- ---__- -----, - -------------------------- _i - Detail: BIRDSELL / 4.88kW SOLAR ARRAY - (16) 0. CELL Q.PEAK-G4.1 305W MODULES W/ (�6) EN PHASE,IC?-60-2-US MICROINVERTERS [288SF] 2016 CALIFORNIA ELECTRICAL CODE. MPATP 17tit 1'i94M9 i=iV?� DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT CITY AMOUNT Credit Card Fee 101-0000-43505 0 $3.07 Total Paid for Credit Card Fee: $3.07 DESCRIPTION ACCOUNT CITY AMOUNT PV SYSTEM LESS THAN 10KW 101-0000-42403 0 $26.68 DESCRIPTION ACCOUNT CITY AMOUNT PV SYSTEM LESS THAN 10KW PC 101-0000-42600 0 $26.68 Total Paid for ELECTRICAL: $53.36 DESCRIPTION ACCOUNT CITY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $101.40 Total Paid for PERMIT ISSUANCE: $101.40 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 ta CAI Project Address: APN #: Applicant Name: Address: 7 S 3 a] City, ST, Zip: , 0. Telephone: (b �-- Email: Contractor Name: Address - city, St, Zip Telephone: Email. State Lich "fi-Al City Bus Lic: Architect/Engineer Name: Address: City, St, Zip Telephone: Email: State Lic: City Bus Lic: Property Owner's Name: %� I C7G ��J 1 r cl S.-r Address: c f ?65-1 S City, ST, Zip Telephone: Email: MIT # C P6 J Project Description: so Valuation of Project $ ( & uu — ew SFD Construction: Conditioned Space Garage Patio/Porch Fire Sprinklers Construction Grading: Bedrooms: I Stories: SF SF SF SF Occupancy: # Units: New Commercial / Tenant Improvements: Total Building SF Construction Type: Occupancy: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 OFFICE USE ONLY # 1 Submittal � Required , Received Plan Sets Structural Calcs Truss Calcs Title 24 Calcs Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License TT11 PALM DESERT CONTRACTORS P.O. Box 2795 Palm Desert California, 92261 Lic# 477507 760-250-9095 DATE; 4-4-19 CONTRACTORS PLAN SOLAR PROPOSAL PROPOSAL submitted to; WORTS to be performed at; Joe La Quinta Ca.. Palm Desert contractors hereby proposes to furnish material and perform the labor necessary for the completion of; Install a 4880 watt solar system as follows: install system on roof, install 16 Q Cell. 305 watt black frame solar panels, install 16 Enphase IQ7 micro- inverters, install envoy controller, install Uni Rae racking system, install AC disconnect and new breakers in main panel as needed. Engineering included. EXTRAS: permit, Edison fees. The work will be performed in accordance with the drawings and specification submitted for the above work and completed in a workman like manner for the sum of; $15860.00 With payments as follows: $ down, Balance upon completion Respectfully submitted ACCEPTANCE OF PROPOSAL The above price, specification and conditions are satisfactory and are hereby accepted. Palm Desert Contractors is authorize) to do the work as specified. Payments will be. made as outlined. Date-_? Signature� Ulk TITLE PAGE NOTES Ac. # 477507 48751 San Lucas La Quinta, CA 92263 SCOPE OF WORK 1. ONE (1) 4.88 KW ROOF MOUNTED SOLAR SYSTEM TO BE INSTALLED BY CONTRACTOR, EMPIRE ENERGY SOLUTIONS. CONNECTED BY A LOAD SIDE AC CONNECTION. 2. SYSTEM IS MADE UP OF (16) Q CELL Q.PEAK-G4.1 305 305 Watt PHOTOVOLTAIC MODULES (16) Enphase Energy IQ7-60-2-US (240V)) [SI1] MICROINVERTERS. UNIRAC RAILS AND UNIRAC MOUNT STANCHIONS SUPPORTS. 3. ROOF IS: Flat Roof 4. ALL ELECTRICAL WIRING AND CONDUIT SHALL BE PER SINGLE LINE DIAGRAM. S. ROOF COVERAGE SHALL BE DESIGNED, INSTALLED & MAINTAINED IN ACCORDANCE WITH THIS CODE. THE MANAFACTURERS INSTRUCTIONS & SHALL SERVICE TO PROTECT THE BUILDING AND/OR STRUCTURE PER CBC 1502 CITY OF LA QUINT BUILDING & SAFETY DFP' APPROVED FOR CONSTRUCTION DATE?4I' ` B 7. THE CONTRACTOR, PALM DESERT CONTRACTORS SHALL CONFIRM THE INSTALLATION OF BOTH THE FIRE SMOKE ALARMS AND CARBON MONOXIDE ALARM PRIOR TO SCHEDULING FINAL INSPECTION OF THE (PV) SYSTEM. PALM DESERT CONTRACTORS SHALL ARRANGE ACCESS FOR THE INSPECTOR AT THE TIME OF FINAL INSPECTION OR PROVIDEDA COMPLETED AFFIDAVIT FROM. THE OWNER CONFIRMING THE INSTALLATION. SMOKE & CARBON MONOXIDE ALARM 8. ALL CONSTRUCTION SHALL COMPLY WITH WITH THE 2016 CALIFORNIABUILDING, RESEDENTIAL MECHANICAL, ELECTRICAL, PLUMBING, ENERGY, AND GREEN BUILDING CODES AND THE LA QUINTA MUNICIPAL CODE. Insured Bonded GLAR PA M DESERT CONTRACTORS "Affordable Solar" PALM DESERT CONTRACTORS P.O.Box 2795 PALM DESERT, CA 92261 (760)636-8348 CALIFORNIA CODES: 2016 CALIF. BUILDING CODE 2016 CALIF. PLUMBING CODE 2016 CALIF. RESIDENTIAL CODE 2016 CALIF. ENERGY CODE 2016 CALIF. MECHANICAL CODE 2016 CALIF. ELECTRICAL CODE PHOTOVOLTAIC EQUIPMENT: SHEET TITLES: PV-0 TITLE PAGE & NOTES PV-1 SITE PLAN PV-2 SINGLE LINE DRAWING - ELECTRICAL PV-3 STATIC LOAD = PV-4 WARNING LABELS & GROUNDING PV-5 I CUTSHEETS INVERTERS PV-6 CUTSHEETS PHOTOVOLTAIC MODULES PV-7 CUTSHEETS ATTACHMENTS PV-8 CUTSHEETS RAILS (16) Q CELL Q.PEAK-G4.1 305 305 Watt PHOTOVOLTAIC MODULES (16) Enphase Energy IQ7-60-2-US (240V)) [SI1] MICROINVERTERS. TOTAL SYSTEM KW: 4.88 kW/DC, (16) MODULES AT 10 DEG. TILT, AND @ AZIMUTH:154 DEG. LISTED BY UNDERWRITERS LABORATORIES FOR ELECTRICAL AND FIRE SAFETY (CLASS C FIRE RATING). 1. NOTE: NO DISCHARGE OF ANY POLLUTANTS TO ANY STORM DRAIN SYSTEM. RECEIVED 2. THIS PROJECT SHALL COMPLY WITH THE 2016 CBC, CMC, CPC & CEC. 3. ALL MODULES SHALL COMPLY WITH U.L. 1703 4. ALL INVERTERS SHALL COMPLY WITH U.L. 1741. JUL 16 20 19 GENERALS NOTES: 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION. 2. NO SHEET METAL OR TECH SCREWS SHALL BE USED TO GROUND DISCONNECT ENCLOSURE WITH TN -PLATED ALUMINUM LUGS. GROUNDING /GROUND BAR KITS SHALL BE USED. 3. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES SHALL BE U.L. LISTED RAIN TIGHT & SHALL BE APPROVED FOR WET LOCATIONS PER (NEC 314.15a) 4. ADEQUATE SPACING SHALL BE MAINTAINED BETWEEN ANY PLUMBING VENTS EXTENDING THROUGH THE ROOF AND UNDERSIDE OF THE PV PANELS. S. SEPARATION DISTANCE FROM ROOF TO BOTTOM OF PV MODULES SHALL BE A MINIMUM OF 4". 6. GROUNDING BUSHING ARE REQUIRED AROUND PRE -PUNCHED CONCETRIC KNOCKOUTS ON THE DC SIDE OF THE ELECTRICAL SYSTEM (NEC 250.97) 7. BACK -FED CIRCUIT BREAKERS MUST BEAT THE OPPOSITE END OF THE BUSBAR FROM THE MAIN CIRCUIT BREAKER OR MAIN LUGS SUPPLYING CURRENT FROM THE UTILITIES. 8. ALL CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT. CITY OF i A QUINTA "I'll AND DEVELOPMENT DEPMNENT 9. NO BUILDINGS, PLUMBING OR MECHANICAL SHALL BE COVERED BY THE SOLAR ARRAY. 10. SMOKE AND CARBON MONOXIDE ALARMS REQUIRED BY CRC R314 & R315 11. THIS PROJECT SHALL COMPLY WITH THE 2016 CRC SECTION R331 R331.4. FOR ACCESS AND 36" PATHWAY FOR THE PV ARRAY. 12. PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING, MAR- KING TAPE, TAGGING, OR OTHER APPROVED MEANS. THE MEANS OF GROUPING SHALL BE WIRE TIES OR SIMILAR MEANS AT LEST ONCE, AND THEN AT INTERVAL NOT TO EXCEED SIX(6) FEET. (CEC 690.4 (B)) 13. PHOTOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL ASSOCIATED WIRING AND U INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED PERSON. (CEC 690.4(E)) 14. OVERCURRENT DEVICES SHALL BE SIZE TO CARRY NOT LESS THAN 125% OF THE MAXIMUM CURRENTS AS CALCULATED IN 690.8(A). (CEC 690.8(B)1)) 15. MEANS SHALL BE PROVIDED TO DISCONNECT ALL CURRENT -CARRYING CONDU- CTORS OF A PHOTOVOLTAIC POWER SOURCE FROM ALL OTHER CONDUCTORS IN A ■ BUILDING OR OTHER STRUCTURE. (CEC 690.13) tow 16. CIRCUIT CONDUCTORS SHALL BE SIZE TO CARRY THE LARGER OF 125% OF THE MAXIMUM CURRENTS CALCULATED IN 690.8(A) WITHOUT ANY ADDITIONAL CORRECTION FACTORS FOR CONDITIONS OF USE OR 100% OF THE MAXIMUM CURRENT AFTER CONDI- TIONS OF USE HAVE BEEN APPLIED. CEC 690.13) 17. CONDUCTORS INSTALLED WITHING RACEWAYS LOCATED IN WET LOCATIONS, ITHER ABOVE GROUND OR UNDERGROUND, SHALL COMPLY WITH 310.8(C). (CEC 300.5(B) CUSTOMER INFORMATION Drawn sy: Francisco Rosas JOE BIRDSELL Signed: Date: 7/15/2019 48751 SAN LUCAS California tic # License Class Expiration Date a e: 15�201 LA QUINTA, CA 92263 477507 B - C39 08/31/2019 Scale: NTS 0 3`' R CA 4116J SITE PLAN Address: : San Lucas 3l ulluinda" Map Satellite r Enphase Comunication Box (In Garage) AC Disconnect + 100 AMP NEMA 3R RAIN - PROOF Utftd.: AA.Uh (true): ® ., . Share Longitude: AZIMUTH : 154 DEG. Modules @ : 10 deg ROOF COMPOSITION: Flat Roof This is a 4.88kW/DC Solar Electric System using (16) Q CELL Q.PEAK-G4.1 305 305 Watt PHOTOVOLTAIC MODULES GRID INTERTIED VIA (16) Enphase Energy IQ7-60-2US (240V)) [SI1] MICROINVERTERS. (1) STRING OF 16 ALL EMT CONDUIT TO BE PAINTED TO MATCH DWELLING. THIS PROJECT SHALL COMPLY WITH THE 2016 CALIFORNIA BULDING CODE. (16) Q CELL Q.PEAK-G4.1 305 305 Watt PHOTOVOLTAIC MODULES Lie. # 477507 Insured Bonded tot : EFRCORCOPM 0SATRS "Affordable Solar" 65.7" 200A MAIN SERVICE PANEL (busbars rated for (200A) PALM DESERT CONTRACTORS P.O.Box 2795 PALM DESERT, CA 92261 (760) 636-8348 CUSTOMER INFORMATION � f ]OE BIRDSELL 48751 SAN LUCAS LA QUINTA, CA 92263 } �Coa Pt0 ned: California (1) ]-BOX (16) Q CELL Q.PEAK-G4.1 305 305 Watt PHOTOVOLTAIC MODULES - - -- (16) Enphase Energy IQ7-60-2-US (240V)) [SI1] MICROINVERTERS. i ATTACHMENT POINTS 48" OC MAX Date: 7/15/2019 License Class Expiration Dat 477507 B - C39 08/31/201 Drawn By: Francisco Rosas Pv t 019 Scale: NTS SINGLE LINE DRAWING L ARRAY J-BOX E INVERTERS (1) Q CELL Q.PEAK-G4.1 305 305 Watt PHOTOVOLTAIC MODULES } J-BOX I (16) Enphase Energy IQ7-60-2-US (240V)) [SI1] r (16) Q CELL Q.PEAK-G4-1 305 I I ) (16) Enphase Energy (1) STRINGS OF 16 305 Watt PHOTOVOLTAIC MODULES I I MICROINVERTERS. ! IQ7-60-2-US (240V)) [SII] EE ::I[ Nominal output current: 1A MICROINVERTERS. ` i�l I I Nominal voltage: 240VAC Maximum units per branch: 16 I I I END CAP ------ o I I (2) #10THWN-2 I ° / (1) #8 Gn ENPHASE TRUNK CABLE u 3/4" EMT Conduit (1) #6 Gn bare copper e NOTES 1. NET SYSTEM INFORMATION: INVERTER MFG & MODEL NO: (16) Enphase Energy IQ7-60-2-US (240V)) [SI1] MICROINVERTERS. EFFICIENCY RATING: 96.0% PV MODULES PER UNIT: 1 2. THE SYSTEM IS A NEGATIVELY GROUNDED ARRAY. 3. WIRE AND CONDUIT SIZES ARE AS INDICATED OR LARGER. 4. ALL EQUIPMENT IS BONDED BY MECHANICAL MEANS OR BY A GROUNDING CONDUCTOR. 5. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE #8 AWG COPPER GROUND WIRE AND BONDED TO THE EXISTING GROUNDING ELECTRODE SYSTEM. 6. ALL MARKING SHALL BE WHITE LETTERING ON RED BACKGROUND, ALL CAPITALS, ARIAL OR SIMILAR FONT, NON -BOLD, 3/8" MINIMUM LETTER HEIGHT, REFLECTIVE, WEATHER RESISTANT MATERIAL. Max AC Operating Current: 20A Operating AC Voltage: 240V 8. PROVIDE MARKING FOR ALL CONDUITS AND CABLES (MARKED EVERY 10 FEET), ENCLOSURES, JUNCTION BOXES, ETC. INDICATING THAT THEY ARE PART OF A SOLAR PHOTOVOLTAIC SYSTEM: THE INSTALLTION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE PERFORMED ONLY BY QUALIFIED PERSON. (CEC 390.4C) AC DISCONNECT Cutler Hammer DH364UGK Heavy 100 Amp 600v (2) #10THWN-2 (1) #8 Gn 3/4" EMT Conduit ! I I ] a u I 6o c,ee- m-aaa moo-aec. uao.-�.��.�.aQ.-9.�vi-------a-eaa.aQ aep�,�o00oe--me�®® o0oe I I Using ASHRAE High Temperature Data and Roof Temperature adjustments. Ambient Temperature = 29*C Table 310,15(6)(3)(c), 3.5-12 inches off roof =17 *C temperature increase Effective temperature = 29*C + 17*C = 46*C Table 310.15(B)(2)(a), 90*C temp. column at 46-50*C = .82 correction factor Tahla 310. 15f R 11311 a) 4-6 rnnA rrFnre = I MAIN SERVICE Existing 200A Center Fed 200 X 1.2 = 40A 40A > 20A OK ENPHASE IQ COMMUNICATION /COMBINER 10. PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS SHALL NOT BE CONTAINED a I� IN THE SAME RACEWAY, CABLE TRAY, CABLE, OUTLET BOX, JUNCTION BOX, OR SIMILAR FITTING AS CONDUCTORS, FEEDERS, BRANCH CIRCUITS OF OTHER NON-PV SYSTEMS, OR INVERTER OUTPUT CIRCUITS UNLESS THE CONDUCTORS OF OF THE DIFFERENT SYSTEMS ARE SEPARATED BY A MEANS Monitoring OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING, MARKING TAPE,TAGGING, OR OTHER APPROVED MEANS. (CEC 690.31) OCPD Lie. # 477507 Insured Bonded PA M DESERT CUHkTARACTnUC "Affordable Solar" (15A) PALM DESERT CONTRACTORS I CUSTOMER INFORMATION P.O. Box 2795 PALM DESERT, CA 92261 (760) 636-8348 JOE BIRDSELL 48751 SAN LUCAS LA QUINTA. CA 92263 MAIN SERVICE MAIN I Existing 200A�Top fed, 2 pole, — mainservice brealler (busbar 200A) 240V electric I enphase .� envoy ':` service 1M1 from 1 I utility i I (2) #10THWN-2 1 I 20A 2P 3/4" EMT Conduit !� Solar Breaker 1 000m®imm4 a -- 15A 2P 20A I r` CUSTUMER PANEL EXISTING GROUND BUS BAR UFER GROUND 2 pole, mainservice breaker(busbars rated for 200A) (1) ONE STRING # 16 ARRAY TO ENPHASE Q AGGREGATOR WIRE SIZING CALCULATIONS M = Imax x 1.25of Modules x 1.25 = x AA=20A Derate Ampacity = 90deg Rating of Conductor (T-310.16) x 90deg Temp Correction Factor (T-310.16) x Conduit Fill Factor (T-310.15(B)(2)(a) = 40 A x .82 x .80 = 26.24 A (use 10 AWG) So that, Derate Ampacity > Continuous Current 26.24A>20A»OK And, Derate Ampacity > Overcurrent Device Rating 26.24 A > 20 A >> OK OCPD CB (20A) PER STRING AC DISCONNECT TO MAIN WIRE SIZING CALCULATIONS M Current = Imax x 1.25 Number of Modules x 1.25 = x A16= 16A16X1.25=20A Derate Ampacity = 90deg Rating of Conductor (T-310.16) x 90deg Temp Correction Factor (T-310.16) x Conduit Fill Factor (T-310.15(B)(2)(a) = 40 A x .82 = 32.8 A (use 10 AWG) So that, Derate Ampacity > Continuous Current 32.8A>20A»OK And, Derate Ampacity > Overcurrent Device Rating 32.8 A > 20 A >> OK OCPD CB (20A) PER STRING OCPD (20A) Drawn B : Francisco Rosas Si Red: Date: 7/15/2019 Date 15/2019 California U e # License Class Expiration Date 477507 B - C39 08/31/2019 Scale: NTS ROOF Layout UniRac F ENLARGED PARTIAL ROOF PLAN DETAIL 1LA1_-)u1ty c A -F tatt-ct (spaced @ 16" O.C.) SOLAR MODULE MOUNTING DETAIL C UniRac 2-piece standoff (spaced up to 72" O.C.) 2X4" engineered trusses, 16" OC Ac. # 477507 Insured Bonded rL�fr ILTAR TOSPM DESERT �GR .4 ordable Solar" Photovoltaic Module PHOTOVOLTAIC MODULE STATIC LOAD TEST SUi3 C E R T I F I C A T E. Product Service No. Z2 16 02 76729 036 Holder of Certificate: Seraphim Solar System Co.,Ltd. Linnan, Henglin Zhen Wujin District 213101 Changzhou, Jiangsu PEOPLE'S REPUBLIC OF CHINA 0�_ r Certification Mark: 0SUD0 Product: Crystalline Silicon Terrestrial Photovoltaic (PV) Modules Mono -Crystalline Silicon Photovoltaic Module The product was tested on a voluntary basis and complies with the essential requirements. The certification mark shown above can be affixed on the product. It is not permitted to alter the certification mark in any way. In addition the certification holder must not transfer the certificate to third parties. See also notes overleaf - Test report no. Valid until: 704061346608-01 2021-02-02 Date, 2016-02-03 ( Zhulln Zhang ) Page 1 of 2 a TOV SOD Product Service GmbH Zeriifizierstelle Ridlerstrage 65 • 80339 MOnchen Germany TUv PALM DESERT CONTRACTORS P.O. Box 2795 PALM DESERT, CA 92261 (760) 636-8348 CUSTOMER INFORMATION ❑=BIRDSELL Signed; 8California LA 477507 License Class B-C39 CERTIFICATE No. Z2 16 02 76729 036 �Tl'1V SlIG Product Service Model(s): SRP-270-6MA, SRP-275-6MA, SRP-280-6MA, SRP-285-6MA, SRP-290-6MA, SRP-295-6MA, SRP-300-6MA, SRP-305-6MA, SRP-310.6MA, SRP-315-6MA, SRP-320-6MA, SRP-325-6MA, SRP-330.6MA, SRP-335-6MA, SRP-340-6MA, SRP-225-6MB, SRP-230.6MB, SRP-235-6MB, SRP-240-6MB, SRP-245-6MB, SRP-250-6MB, SRP-255-6MB, SRP-260-6MB, SRP-265-6MB, SRP-270.6MB, SRP-275-6MB, SRP-280-6MB. Parameters: Rated Output Power at STC: 270W, 275W, 28OW, 285W, 290W, 295W, 300W, 305W, 310W, 315W, 320W, 325W, 330W, 335W, 340W, 225W, 230W, 235W, 240W, 245W, 250W, 255W, 260W, 265W, 270W, 275W, 28OW, Application Class: Class A Max, System Voltage: 1000V DC Test Laboratory: Yangzhou Opto-electrical product testing institute No.10 West Kaifa Road, Yangzhou, 225009 Jiangsu P R.China Construction: Framed, with Junction box, cable and connector Fire Safety Class: Class C PIE) Test Condition: t1000V DC, 96 h, 85% RH, 60°C Tested IEC 61215(ed.2) according to: IEC 61730-1(ed 1);aml;am2 IEC 61730-2(ed.1);aml PPP 58042B:2015 Production 76729 Facility(ies): J{ Page 2 of 2 S a TOV SOD Product Service GmbH • Zertifizierstelle • Ridlerstr8ge 65 • 80339 MOnchen Germany Date: 7/ 15/2019 expiration Date 08/31/2019 Drawn B ; Francisco Rosas Date: /15/2019 Scale: NTS TW0 PV 3 RAPID SHUTDOWN Enphase® Energy // Rapid Shutdown Rapid shutdown is built-in The 2014 edition of the National Electrical Code (NEC 2014) added What's new in NEC 2014? new rapid shutdown requirements for PV systems installed on buildings. NEC 2014, Section 69012 applies Enphase Microinverters fully meet rapid shutdown requirements in the to PV conductors over 10 feet horn new code without the need to install any additional electrical equipment. the PV array and requires that the conductors power down to 30 volts and 240 volt-amperes within 10 seconds of rapid shutdown initiation. String inverters require work arounds for rapid shutdown Work around. Specialized Rapid Shutdov electrical box installed on ti roof within 10 feet of array. Work around. Shutoff switch that is easily accessible to first responders on the ground. Work around. Extra conduit in installation. Residential String Inverter Work around. String inverter installed on roof, a hostile environment that string Inverters are not guilt to live in. Commercial String Inverter Enphase comes standard with rapid shutdown capability All Enphase microin- verters, even those that were previously installed, inherently .meet rapid shutdown requirements, no additional equipment or workarounds needed Residential Microinverter To learn more, visit enphase.com Ac. # 477507 PA DESERT CONTARACTORS "Affordable Solar" lnsu Enphase microinverters can safely shut down automatically. leaving only low -voltage DC electricity isolated to the PV module PALM DESERT CONTRACTORS P.O. Box 2795 PALM DESERT, CA 92261 (760) 636-8348 Commercial Microinverter [e] enphase- E N E R G Y CUSTOMER INFORMATION JOE BIRDSELL 48751 SAN LUCAS LA QUINTA, CA 92263 TECHNICAL BRIEF NEC 2014 — Enphase System Code Compliance Overview [e] enphas& E N r R _a Y This technical brief discusses new NEC 2014 requirements that apply to Enphase Microinverter Systems. It is useful for installers, electricians, and electrical inspectors or authorities having jurisdiction (AHJs) in understanding how code -compliance is handled where NEC 2014 is adopted. Main topics discussed in this document are: • NEC 2014 Section 690.12 Rapid Shutdown of PV Systems on Buildings • NEC 2014 Section 705.12 Point of Connection • NEC 2014 Section 690.11 DC Arc -Fault Circuit Protection NEC 2014 Section 690.12 Rapid Shutdown of PV Systems on Buildings Enphase Microinverter Systems fully meet the rapid shutdown requirement without the need to install additional electrical equipment. Properly labeling the PV system power source and rapid shutdown ability is required per NEC Section 690.56 (B) and (C). Solar electric PV systems with Enphase Microinverters have one utility -interactive inverter directly underneath each solar module, converting low voltage DC to utility grid -compliant AC. When the utility grid is available and the sun is shining, each microinverter verifies that the utility grid is operating within the IEEE 1547 requirements. Only then does it export AC power into the electric service for use by loads onsite or export power to the utility grid for others to use. When the utility grid has a failure, or the PV system AC circuits are disconnected from the utility service via an AC breaker, AC disconnect, or removal of the solar or main utility service meter, the microinverters stop producing AC power in fewer than six AC cycles. Enphase Microinverters are not capable of operating as an AC voltage source. This means that without an AC utility source, Enphase Microinverters are not able to energize connected wiring and no AC voltage or current can be injected into the inverter output circuits or the grid. When the AC utility source is removed from the inverter output circuits via any means, such as an AC breaker, AC disconnect or removal of the solar or main utility service meter, this equipment performs the rapid shutdown function per 690.12. With an Enphase Microinverter System this shutdown occurs well within the 690.12 required 10 seconds, and there are no other conductors energized more than 1.5 m (5 ft) in length inside a building or more than 3 m (10 ft) from a PV array. Code Reference 690.12 Rapid Shutdown of PV Systems on Buildings. PV system circuits installed on or in buildings shall include a rapid shutdown function that controls specific conductors in accordance with 690.12(1) through (5) as follows. (1) Requirements for controlled conductors shall apply only to PV system conductors of more than 1.5 m (5 ft) in length inside a building, or more than 3 m (10 ft) from a PV array. (2) Controlled conductors shall be limited to not more than 30 volts and 240 volt-amperes within 10 seconds of rapid shutdown initiation. (3) Voltage and power shall be measured between any two conductors and between any conductor and ground. (4) The rapid shutdown initiation methods shall be labeled in accordance with 690.56(B). (5) Equipment that performs the rapid shutdown shall be listed and identified. 0 2015 Enphase Energy Inc All rlghls reserved Signed: Date: 7/15/2019 California Lic3DW7 License Class Expiration Date 477507 B - C39 08/31/2019 Drawn B : Francisco Rosas r Date: 6/ 15/2019 Scale: NTS January 2015 PV 3a 7 CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOUR( WITH DISCONNECTS LOCATED AS SHOW AC DISCONNECT FOR -_ UTILITY OPERATION _ N ■ SERVICE PO UTILITY MI iASE COMBINER MUNICATION BOX SOLAR ARRAYS ON ROOFTOP SYSTEM UTILIZES MICROINVERTERS LOCATED UNDER EACH SOLAR MODULES LABEL LOCATED ON INTERACTIVE SYSTEM POINT OF INTRCONNECTION NEXTTO OVERCURRENT PROTECTION DEVICE PER 690.54 6 LABEL LOCATED ON PHOTOCOLTAIC SYSTEM DISCONNECTS WHERE THE LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE OPEN POSITION PER 690.13(B) FDP REQUIREMENTS: SEC.5. MARKING, LABELS, AND WARNING SIGNS. L � PHOTOVOLTAIC REQUIREMENTS PER CALIFORNIA (ELECTRICAL. CODE ARTICLE 690 PHOTOVOLTAIC REQUIREMENTS PER CALIFORNIA ELECTRICAL CODE ARTICLE 690 LABEL LOCATED ON INTERACTIVE SYSTEM POINT OF INTRCONNECTION PER 690.54 LABEL LOCATED ON DEDICATED PV SUB PANEL PER 690 LABEL LOCATED ON RAPID SHUT DOWN DISCONNECT SWITCH PER 690.12 LABEL LOCATED ON INTERACTIVE SYSTEM POINT OF INTRCONNECTION PER 690.54 A. PURPOSE: PROVIDES EMERGENCY RESPONDERS WITH APPROPIATE WARNING AND GUIDANCE WITH RESPECT TO ISOLATING THE SOLAR ELECTRICAL SYSTEM. THIS CAN FAILITATE IDENTIFYING ENERGIZED ELECTRICAL LINESTHAT CONNECT THE SOLAR PANELS TO THE INVERTER, AS THESE SHOULD NOT BE CUT WHEN VENTING FOR SMOKE REMOVAL. B. MAIN SERVICE DISONNECT: Lic. # 477507 1. RESIDENTIAL BUIILDINGS - THE MARKING MAY BE PLACE WITHIN THE MAIN SERVICE DISCONNECT. THE MARKING SHALL BE PLACE ON THE OUTSIDE OVER IF THE MAIN SERVICE DISCONNECT IS OPERABLE WITH THE SRVICE PANEL CLOSED. 2. COMMERCIAL BUILDING - THE MARKING SHALL BE PLACE ADJACENT TO THE MAIN SERVICE DISCONNECT CLEARLY VISIBLE FROM THE LOCATION WHERE THE LEVER IS OPERATED. Insured Bonded PALM DESERT CONTRACTORS SOLAR PQ M DEW CONTRACTORS "Affordable Solar" P.O.Box 2795 PALM DESERT, CA 92261 (760) 636-8348 1 z K3 EA I J-Box AC Combiner Load AC Disconnect / F AC Disconnect / 3. MARKING: VERBIAGE, FORMAT, AND TYPE OF MATERIAL. a. VERBIAGE: WARNING: PHOTOVOLTAIC POWER SOURCE. b. FORMAT: (1) WHITE LETTER ON RED BACKGROUND. (2) MINIMUM 3/8 INCHES LETTER HIGH. (3) ALL LETTERS SHALL BE CAPITALIZED. (4) ARIAL OR SIMILAR FONT, NON BOLD. c. MATERIAL: r�aui .�c�r�w rand r.rl Vf ■ C. MARKING REQUIREMENTS ON DC CONDUIT, RACEWAY, ENCLOSURES, CABLE ASSEMBLIES, DC COMBINERS, AND JUNCTION BOXES: 1. THE AC/DC CIRCUIT WILL BE LABELED EVERY 10' ON PV CONDUIT INCLIDING JUNCTION BOX, AT TURNS AND ABOVE OR BELOW PENETRATIONS WITH WHITE LETTERING ON RED REFLECTIVE WEATHER RESISTANT BACKGROUND MATERIAL SUITABLE FOR THE ENVIROMENT WITH DURABLE ADHESIVE COMPLYING WITH UL-969 STANDARDS. FONT: ARAIL 3/8" NnN-Rni Ml FTTFDTMr TN Al I rADrrAI c NING SIGNS: TO BE ARAIL FONT MUM 3/8" NON BOLD LETTERING, ALL TOLS WITH WHITE LETTERING ON RED :GROUND MADE OF WEATHER STANT MATERIAL. 2MANENT LABELS SHALL BE DVIDED, NO SHARPIE RKING WILL BE ALLOWED WITHIN IN SERVICE PANEL OR SUBPANEL. 1. MARKING: PLACEMENTS, VERBIAGE, FORMAT, AND TYPE OF MATERIAL. a. PLACEMENT: MARKINGSSHALLBE PLACED EVERY 10 FEET ON ALL INTERIOR AND EXTERIOR DC CONDUITS, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES AT TURNS ABOVE AND/OR BELOW PENETRATIONS, ALL DC COMBINERS, AND JUNCTION BOXES. b. VERBIAGE: CAUTION: SOLAR CIRCUIT NOTE: THE FORMAT AND TYPE OF MATERIAL SHALL ADHERE TO "SEC. 5. B-3b & c" OF THIS REQUIREMENT. (1) REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE D. INVERTER - A WARNING LABEL SHALL APPEAR ON THE UTILITY-INERACTIVE INVERTER OR ENVIROMENT (USE UL -969 AS STANDARD FOR WEATHER RATING). BE APPLIED BY THE INSTALLER NEAR THE GROUND -FAULT INDICATOR AT VISIBLE DURABLE ADHESIVE MATERIAL MEET THIS REQUIREMENTS. LOCATION. CUSTOMER INFORMATION QSELL 8751 N LUCOE AS TA, CA 92263 Drawn By: Francisco Rosas Signed: Date: California Licen License Class Expiration Date Date: 15/201 7507 B - C39 08/31/2021 Scale: NTS Pv Lic. # 477507 i� -Ito Enphase Microinverters C�ng[ F C,r S Enphase IQ 7 and IQ 7+ Microinverters 9 To learn more about Enphase offerings, visit enphase.com Insured Bonded :t4li SUN: �k: PA M DESERT CONTRACTORS "Affordable Solar" MICROINVERTER The high-powered smart grid -ready Enphase IQ 7 Micro" and Enphase IQ 7+ Micro'" dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy", Enphase IQ Battery', and the Enphase Enlighten" monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Easy to Install Lightweight and simple Faster installation with improved, lighter two -wire cabling Built-in rapid shutdown compliant (NEC 2014 B 2017) Productive and Reliable Optimized for high powered 60-cell and 72-cell* modules More than a million hours of testing • Class II double -insulated enclosure • UL listed Smart Grid Ready Complies with advanced grid support, voltage and frequency ride -through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) ' The IQ 7+ Micro is required to support 72-cell modules. PALM DESERT CONTRACTORS P.O. Box 2795 PALM DESERT, CA 92261 (760) 636-8348 -3ENPHASE CUSTOMER INFORMATION ]OE BIRDSELL 48751 SAN LUCAS LA QUINTA, CA 92263 Enphase IQ 7 and IQ 7+ M INPUT DATA (DC) I47-60-2-US / I07-60-B-US 7PLUS-72-2-US / IQ7PL11S-72-S-US Commonly used rr10dul•' pairings' 235 W -350 W + 16 W - 440 W + Module compatibility 60-cell Pv modules only 1-,-01 and 72-cell PV modules Maximum input DC voltage 48 V v Peak power tracking voltage 27 V - 37 V V - 45 V Operating range 16 V - 48 V V - 60 V Min/Max start voltage 22 V / 48 V V 160 V Max DC short circuit current (module Isc) 15 A A Overvoltage class DC port II DC port backfeed current 0 A A PV array configuration 1 x 1 ungrounded array, No addition a C side protection required; AC side protection requires max 20A •r branch circuit OUTPUT DATA (AC) IQ 7 Mlcroinverter Q 7+ Mlcralnvertar Peak output power 250 VA )5 VA Maximum continuous output power 240 VA )0 VA Nominal (L-L) voltage/range' 240 V / 208 V / Rr V / 208 V / 211-264V 183-229V r1-264V 183-229V Maximum continuous output current 1.0 A (240 V) 1.15 A (208 V) ?1 A (240 V) 1 39 A (208 V) Nominal frequency 60 Hz Hz Extended frequency range 47 - 68 Hz 68 Hz AC short circuit fault current over 3 cycles 5 8 Arms R Arms Maximum units per 20 A (L L) branch circuiP 16 (240 VAC) 13 (208 VAC) 1 (240 VAC) 11 (208 VAC) Overvoltage class AC port III AC port backfeed current 0 A A Power factor setting 1.0 0 Power factor(adjuslable) 0 85leading 0 85 lagging IS leading.... 0.851ag In EFFICIENCY @240 V @208 V 240 V @208 v Peak efficiency 97.6 % 97.6 % 7.5 iii97 3 % CEC weighted of fic+ency 97.0 % 97, 0 % 1 0 % 97 0 % MECHANICAL DATA Arnblent temperature range -40'C to+65'C Relative humidity range 4%to 100% (condensing) Connectortype (IQ7-60-2-US 81Q7PLUS 72-2-US) MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connector type (IQ7-60-B-US$ IQ7PLUS-72-B-US) Friends PV2 (MC4 intermateable) Adaptors for modules with MC4 or UTX connectors: PV2 to MC4: order ECA-S20-S22 PV2 to UTX: order ECA-S20-825 Dimensions (WxHxD) 212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 Ill Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree P03 Enclosure Class II doubie-insulated, corrosion resistant polymeric enclosure Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlrghten monitoring options. Both optionsrequlre installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load -break disconnect required by NEC 690 Compliance CA Rule 21 (UL 1741-SA) UL 62109-1. UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class 8, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Dawn Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC ` and DC conductors, when installed according manufacturer's instructions. 1. No enlnrcall DCIAC ratio Sep thu COIft fJ 61 hit I I y calculator al jytlptjLLl'Faf W Le&nm/PRJi9IB�RAaI.i/fl]Ad41C--Cnnlp-9[If211i1y 2- Nominal roll age range can be eYl ended beyond nominal If requited by thu ulttlly. 3. Lim Its may very. Ref or to loc al req urre me nts ro del I no th a nu tuber o f rn rc roinve r tera p at br smith in your afea. To learn more about Enphase offerings, visit enphase.com D 2018 Enphase Energy All nghts reserved Ad uademrksor biauds used ale the properly of Enphase Energy, Inc 201E-11-19 Signed; Date: 7/15/2019 California Lice License Class Expiration Date 7507 B - C39 08/31/2019 ENPHASE. Drawn B : Francisco Rosas r� PV Date: 15/2019 Scale: NTS MO�U�ES The new high-performance module Q.PEAK-G4.1 is the ideal solution for all applications thanks to its innovative cell technology Q.ANTUM. The world -record cell design was developed to achieve the best performance under real conditions - even with low radiation intensity and on clear, hot summer days. LOW ELECTRICITY GENERATION COSTS G Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 18.6%. to INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID technology, Anti PID Technolo gy', Hot -Spot Protect and Traceable Quality Tra.QT"', EXTREME WEATHER RATING High-tech aluminum alloy frame, certified for high snow (5400Pa) and wind loads (4000Pa) regarding IEC. MAXIMUM COST REDUCTIONS Up to 10% lower logistics costs due to higher module capacity per box. A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year linear performance guarantee2. THE IDEAL SOLUTION FOR: 01 RooNop arrays on n-dentlal buildings Engineered in Germany �hi4e PTA PA Nf DESERT"N'COHORS "Superior Quality Roofing" PALM DESERT CONTRACTORS P.O. Box 2795 PALM DESERT, CA 92261 (760) 346-2420 • �ualitY TaetOd I D. dpp325ar cacEus Dhntnn r3C9LS 1.1 looy.".lrne man aadIde 2014 usn41 as ar APT test conditions: Cells at -1500V against grounded, with conductive me- tal foil covered module surface, 25°C, 168h 2 See data sheet on rear for further information. Q CEIIS CUSTOMER INFORMATION V IRDSELL 1 SAN LUCAS UINTA, CA 92263 ed: California 477507 SPECIFICATIONMECHANICAL Format 65.7 in x 39.4in x 1.261n (including frame) (1670mm x 1000mm x 32mm) --`r*_"'• Weight 41.451bs(18.8kg) +..�r,.....n.r.a.q from Cover 0, 131n 13.2 mm) thermally pre -stressed glass with anti -reflection technology o-,,,"••„ •... Back Cover Composite film I Frame Black anodised aluminum " r"•'r I -- Cell 6 x 10 monocrystalllne 0 ANTUM solar cells .. )unction boa 2.60-3.03 in x 3.54-4.53 in x 0.59-0.751n J (66-77mm x 90-115mm x 15.19mm), Protection class IP67, with bypass diodes ,.....,,,,.,,.,,. •'•••""•" Cable 4 mma Solar cable; (+) a39.37in (1000mm), (-) t39.37In (1000mm) Connector Multi -Contact MC4 or MC4 interma[eable, IPfiB ELECTRICAL CHARACTERISTICS POWER CLASS 300 305 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC' (POWER TOLERANCE +5 W /.0 W) Power at MPP' Pan [WI 300 305 Short Circuit Current` Iu [A) 9.77 9.84 Open Circuit Voltage- V. IV) H 39,76 40.05 Current at MPP' Ian [A) 926 9.35 Voltage at MPP' Van IV] 32.41 32-62 Efficiency' q [%1 z 18 0 z 18 3 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NOC' Power at MPP' Pan [W] 222.0 225.7 E Short Circuit Current* I,. [Al 7.88 7.94 g Open Circuit Voltage- V. (VI 37.19 37.46 25 Current at MPP' Ian [A) 7.27 7.35 Voltage at MPP' Vv„ [Vl 30.52 30.70 1000W,rn, 25'C, spachum AM 15G t Measurement tolerances STC:3%; NOC t5% 1800W/0, NOCT, spectrum AM 1.5G 'lypical values, actual values may differ G CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE a:cs+ Al least 98% of nominal power duting first year.- M"t'w'"•'"•e1r` Thavealler max, 0.6%tl adellon w ve.,...-.. r....r....., aHr Per Year. At least 92 6 % of nominal Power up 10 10 years. t w At least 83.6 % of nominal power up to 25 years 3 • -- All dots mitldl mesauremerd lolrrancas- V .. ` Fulls o f the Q in accordance with then of your warranty terms of the Q CELLS sales organization of your respective country. u. nr IRRMIANCE IWIWI „ rtxxs Typical module performance under low madiance conditions in b. w.aw.. ;ten•=<n-..•s.,„.+•mn comparison to STC conditions(25°C, 1000W/m2) TEMPERATURE G'OEFFICIEM. Temperature Coefficient of Iu a [%/KI +0.04 Temperature Coefficient of Vx IS [%/KI -0.28 Temperature Coefficient of P„r, y [%/Kl -0, 39 Normal Operating Cell Temperature NOCT [°FI 113:5 4 (45 t3'C) PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage Vr,s 11i1 1000 (IEC) / 1000 (UL) Safety Class II Maximum Series Fuse Rating (A OCl 20 Fire Rating C (IEC) / TYPE 1 (UL) Design load, push (UL)' Ilbs/fel 75 (360C Pa) Permitted module temperature -40oF up to +185°F on continuous duty (-40'C up to+B5'C) Design load, pull (ULP [Ibs/ff') 55.6 (2666Pa) ' see installation manual QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION UL 1703; VDE Quality Tested; CE-complianp Number of Modules per Pallet 32 IEC 61215 (Ed2); IEC 61730 (Ed 1) application class A NuIn hoe et Pallets per 53' CDmunaar 30 Cher S Numher of Pallets per 40' Container 26 l)VE C 4pus Pallet Dimensions ( L x W x H ) 68.71n x 45, 31n x 46.1 In w•, (1745mm x 1150mm x 1170mm) Pallet Weight 14351bs (651 kg) NM-. Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installalion and use of this product Halmha D L$lS Awflpa Ing- 300 Spectrum Center Drive, Suite 1250. Irvine, CA 92618, USA I TEL+1 949 74B 59 961 EMAIL inquiry®us-q-cells.com I WEB www.q-cells us Date: 7/15/2019 License Class Expiration Date B - C39 08/31/2019 Drawn B : Francisco Rosas Date: 17/2019 Scale: NTS PV 6 TLL Low -Profile Tilt Legs Installation Supplement 2063 US, Des, Patent No, D40,2485, D40,z495, Otherpaentspending, tcroaa '+ Log wiz ADJunAklE tt0 Leg hrbe hoctei FIXED LW MVT Leg parts list (per leg) Wrench Reconxnatded Part Qtt, stn torque R-lbs) Adjustable Leg Leg tube I Lea sswt I Bak 31B"a1`14' 2 Boils, 31B'x3' 1 Forder wit* 39 1 Sort nwt /r I Range nut, 311' 1 M Fixed Leg Leg tout t Boh,31B"x 1.114" 2 911C Is Flange nut, 31r 2 e go U N ! RAC A HILTI GROUP COMPANY P _,-r.l Teti Figure 1, leg end Foot Am m*: Illustrated parb an hen your 4 kn and your SMR rell ml Leg kR perb are listed in the port Imaeolorybelow, Legtube- Fender 3/0' washer bolt Strut nut L Leg strut Figure L Adjustable Leg Crum SocWn Please m ftheseillustrations lhomughiybefore proceeding. The installer is solely rmitai ble for complying with applicable building codes and for all aspects of electrical installation of the Pvarray. Use the parts list to verify that all parts are present, Note that Figures I and 3 illustrate parts from both your leg Idt and your SMR rail sal. taemt edmmn mpmm rnins0emq od mw4k&en ortb,puakiw rkw no mpeNkabeaeenkresm, Ac. All 477507 Insured Bonded zr o Pa M UESE CO LNiRACTORS "Affordable Solar" ATTACHM,ENTS SWH Racking System Data Sheet wnf�„IZLo,vz SWH Racking System Data Sheet Vn2relenwo,2 - OUNIRAC Installation Manual2063 TLLLow-ProfileLei2Kit SolarMount soIARWARiJ30USE SiMWARMSE 0 f�- Figures 3, spacing bdm front and bad red (B) should epprodmeWy aged this dMm between the borer and of the modulo nd the upper L-hrKMd (A), Warranty lnformakon See h*twww.unksc con for current waranry documems and Wornusbn. e . IF U N I RAC 2 PALM DESERT CONTRACTORS P.O. Box 2795 PALM DESERT, CA 92261 (760)636-8348 1411 Broadway Boulevard NE Albuquerque NM 87102.1545 USA CUSTOMER INFORMATION JOE BIRDSELL 48751 SAN LUCAS LA QUINTA, CA 92263 SWH Grounding Mid Clamp Part No, EW-GM•2513, EA•SW-GM•25K EA-SWGM•25E 25'DISTANCE BETWEEN MODULES MODULE MODULE Y I ►X RAIL DI nemlone spedfled In Inches unlessrated Conforms to UL STD 47 (10 AWG) Mid damp material: 304 or 316 stainless steel Bolt & nut material: 304 and/or 316 skinless steel Assembled mid damp weight 0.078 Ibs (with hardware) Assemble mid clamp with one''/4' Grounding T-bolt and one'/4'•20 ASTM F594 serrated flange nut Use antimsehe and tighten to 8 Vlos of torque MODEL 11 T BOLT LEt40TH MODULE HEIGHT EA-SW-GM•25B 50MM <42mm EA•SW.GM-25K 60MM 33.42mm EA•SWGM•HE M " 1 43.50 mm SWH stainless steel mid clamp penetrates solar module frame anodization to create grounding path, SWH stainless steel grounding Tbolt penetrates solar rail anodization to create grounding path. CONFO@MSfO UL 467 U5 L'rre0 Intertek 4009330 9628 Valley Blvd. Rosemead, CA 917701 Phone 626.579-32881 Infopesolorwarehouse,com Signed: California Lic # License Class 477507 B - C39 Date: 7/15/2019 txpiration vate 1 08/31/2019 1 SWH Solar Mount End Clamp MFG•PN: MR•SWEC•35, MR•SWEC•35B, MR•SWEK40, MR-SWEK408, MR•SWEF45, MR•SWEF458, MR•WEE-50, MR•SWEE•SOB Module.. End Clamp _r Rail as n _ — watd WITH KM 1 n ►X Dhnerwrs spechd in Inches unless noted END CLAMP IS i00 LONG End damp material: 6005-T5 extruded aluminum alloy " SIMON Clear or black anodized Bolt A nut material: 304 stainless steel and/or 316 stainless steel End damp weight Varies based on height: 0.052-0.06 Ibs Assemble end clamp with one 1/4'-20 T-bolt and one '/4"-20 ASTM F594 serrated flange nui. Use ardi-seize and tighten to 10 N-Ibs of torque, Modules Heart be installed at least 1,5' from either end of a SWH solar mount rail, CONFORMS TO UL SUB 2703 051's Intertek 4009330 Pert Neme Pad Number Range of Ho4hte (ram) We ht (Ibs ) wwwoiaare Vend damp MRSHo A36 054 'C' black and clamp MR,SWEC 35B 344 .054 'Wend demo MRSW-EKAO 39411 Ow 'K black and clampMR-SWEKAOB 39441 .056 'F' and clamp MR-SW-EF45 4440 .058 'F' black end cle MRS4EF45B 4446 .058 'E' end clam MRSW EE-50 4951 .060 'E' black end dam MRSWEe 49,51 OBO 9 Is i 9628 Valley Blvd, Rosemead CA 917701 Phone 626-579-3288 I Infooesolarwarehouse.com Drawn B :Francisco Rosas PV Date: 15/2019 Scale: NTS W1A� SolarMount" PV's most versatile mounting system Awon i- — RootWuwd opensleutlllre Wso�r.(ampus iallronna Sutullon SGSUIte1R _ xoJ, w•+r:�i"fmt+wk 5olarMRUM is the rnost 4ersattle PV mourlliq rail sNern on the market today, i4r x rnBrrMArr,7ln,iJYtM•erlArrdry rnmponent� file mo>fYlnum {jF41Y�(rj '. alt itlj Ouu W sr}14t Yu"illy PYtrrounlingcliao1Rr. N ulurwsal 904 ftur# rAa 5Wtm tus Owls adrhomYwMh can be Ab5 ft;td tmoa w+dr rsrleiy or W rnau� diritWrvs fa ai:ewaMali• ✓tor jpb sue ianow patnm* a We Near wpontt W901currrytr%wllh hm4rNtnn alwC20 tomDW+urdnwnu4talio m5 an un•6rw r,l aww AM C" artisluxr to hrl;r lots tnA "Ahestcri.lutgn Iso mUNIRAC SULARMOUNT" RAIL OPTIONS F'r; l'1r uJ11rf1g uwl -Ft' 3o4arMW' Yip HOpuarT"I rai pddi0*56uMcA*w.tW to 9V IFoolopUalts lus leparrlt w mal #s'. . V,511 u;onllr:r•;fl rnW'h' Ur.ir,}i.c6titi MODULE MOONT1N6 �tSseln ,ly )Pibi;'+I[r' s•iJt.t t;r(ac Fry hsprittfbr (unips Wb+g BIN Ap3gtfacd w! x AsdeeWr+�rq► cfrre t n mn¢itr`K►saGr wcxr 'tp �.t1M7Jl1r1l�tlrv[tdry _� r?a11t'1!�►n'arAjia7Fr apt�Mri�atdbe •aAk �RUIe'Yfeubrr 5t¢ta,t mwml+'+[ ttd t� • uP cpNurn aanom Mnumma utpa :� :msulnrsarir�err~ e^wUde!0wp,41 iilh"W �cuxM'x mwe'tr Lye IN fn. ( =1111A rldeS W"MUNCIO rmn-Al 02"trig N"tat tr atnsrr,rn.tsea 14uaua t';alr&I ATTACHMENT OPTIONS • i .r.ln S�udOt!h urrsuywdswxrrnelssm ��unin aR*rrpAV"*h* „} a4n'tR.mtt{fd�ttrptple7m^�� -' 0"W4%Olq�%ee;tC . �7npc dlksa� � R4 wndads�re mrr niw sir..,• aDp- rr15•i'¢Ye{f�ialt Senaled l-fed �rflkpwsdwrAtm ++sldetfa�M�t4edlfi�ltal�ltlae �rrdre�ll��m,,. nrdrla�rhin+eprt h �. a� Mr�x.rrtwraaJr� ar. ins' •.,,M,raiiardx•►e�nd . 5t rut•ur• rYtie 3r;Fl! tees :xilarrlka�Rar�v'rc•: �: ,��. i,:r:,mreerq�IlVAaayA, n+¢�p�Yn>da'a��nst-a0 1 •^rR�Ye1r��If�Rs-w�ltnnr� rctFa'r�,r.mrpr]sfu Ngkol" eiV>6) T+rfar6ud` rtknkmFrc las rrtn+oA>g� A h 11krr Lmv 9ur� [emprq r4tncYaha�+nMsutwd muNraal iroPd 4Rtsr�bct toapa+�srg ik rr*+r i SuR,M�rTV�rs.at::rr+wq-xr- ri.mdaetnevblteur ItrlClhFEtaef'rrrY xsrra*pvrsr! '- �- m>sn F.8ukR4 !OP R,ir eA1 � h !7 ri• �Ity i•ao! py 1l atydr�g718tAfKS y;al Tarn aarrt�+r+nre nS>�+�h.. t7ir�asturRY:P ro+xi>'w:wtrc ui SolaIMount• Rad iftimum 11exiltilily • Flush, Nth -profile or low•pfelp rorfliguralions Roof or ground rrmunt Pitched or flat roof Ease of installation • Installer•friendlyromponents • letin,rmted penplration wil#V longeratlathmenl spans than fampetllnre peodorls Duped with tustomer input Gwundint and we management options. Camplele technical iupparl MAIM and rode tompllnnte durumentatim pphe estimator Peron-to•persan customer wrwce (ate cDII)PO Wt for tlnirac mounting sniutions Three rail optionsto anammodate anylo-hsite Incorporated mlo other major product lines � UNIRA( Bright Thinking in Solar • ■ r a ae • ■ r . ■ ■ r ■ a, Al h1U4� I �i Jlllllllllllll y%INSIIJI'� ➢II h�i;: r'�0 � -r-r, pyre innditlan q (very wvup;• �in�-,ndlpa wpldeU step 1S-N ildlllle SS steel '�UNIRA( 1nr • clarMnunl' •wsirm IS Pf telpher :all Unirm ins dorumrntatinn applirdhlr In your buddinx iudf• Wamnlr ;ol,n�touul siuvr,mribvn,tp-vearlimilcr. uroouQ wdrfonty end d yeai Ilmitcd'tuk 1vdffdll(l. rnr I IIIIIpIPIP SAJWNIllheY" 170IVtln1udfl Ilnl• ;uldrMaunl' mridildhnn nldnudl Irmo cut N')A 0i'. 0 0