BELC2019-008578-495 CALLE TAMPICO C& 0 4�+1/
LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Permit Type/Subtype: ELECTRICAL/
Application Number: BELC2019-0085
Property Address: 78895 SUNBROOK LN
APN: 604292002
Application Description: FLAHIVE / ELECTRICAL FOR ABOVE GROUND SPA
Property Zoning:
Application Valuation: $1,900.00
Applicant:
HANDY SCOTSMAN CONSTR & GEN CO
79220 VIOLET COURT
LA QUINTA, CA 92253
Q U
AUG 11 2019 D
CITY OF LA QUINTA
DESIGN & DEVELOPMENT DEPARTMENT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9
{commencing with Section 70001 of Division 3 of the Business and Professions Code, and
my License is in full force and effect.
License 0a s: License No.: 796153
Date: Contractor::
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any
structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the
alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars ($500),:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that he
or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to
construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State
License Law does not apply to an owner of property who builds or improves thereon,
and who contracts for the projects with a contractor(s) licensed pursuant to the
Contractors' State License Law.).
(_) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Na
Lender's Address:
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 8/8/2019
Owner:
DANIEL & KAREN FLAHIVE
78895 SUNBROOK
LA QUINTA, CA 92253
Contractor:
HANDY SCOTSMAN CONSTR & GEN CONST
79220 VIOLET COURT
LA QUINTA, CA 92253
(760)285-1803
Llc. No.: 796193
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
oI It rk for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My workers' compensation insurance carrier and policy number are:
Carrier: EXEMPT Policy Number:_
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: 810 11Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit issued
3s a result of this application , the owner, and the applicant, each agrees to, and shall
Defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
`ollowing issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not
:ommenced within 180 days from date of issuance of such permit, or cessation of work
:or 180 days will subject permit to cancellation.
certify that I have read this application and state that the above information is correct.
agree to comply with all city and county ordinances and state laws relating to building
:onstruction, and hereby authorize representatives of this city to enter upon the above-
nention`edypir perty for inspection purposes.
)ate: QV A Signature (Applicant or Agent):
DESCRIPTION
FINANCIAL INFORMATION
ACCOUNT CITY
AMOUNT
BSAS SB1473 FEE
101-0000-20306 0
$1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA:
$1.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PERMIT ISSUANCE
101-0000-42404
0
$101.40
Total Paid for PERMIT ISSUANCE:
$101.40
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RECORDS MANAGEMENT FEE
101-0000-42416
0
$10.00
Total Paid for RECORDS MANAGEMENT FEE:
$10.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE:
$5.00
CALIFORNIA -
PERMIT #
PLAN L
Project Address: S L)N cv,)
Project Description:
APN #:
r
6 U
Applicant Name: �.f SDI
P dd
Address: i 7Cl 'ZZO 0 L aLL-� C-
City, ST, Zip: v — A CA
Telephone: `7 6 0 2�6 S c6,0
Email: dD_ Ate( err
Valuation of Project $ 0�
.,
Contractor Name:
C S
� &-fE
New SFD Construction:
Address:-72 2-zo
if io Z (zT
Gc
Conditioned Space SF
City, St, Zip LA,
Q U t w ✓1,-
C A
Garage SF
Telephone: 0
Patio/Porch SF
Email:
A.6
F
rstateL'c' 716 1
City Bus Lic:
cf �
Architect/Engineer Name:
Construction Occupancy:
Address:
Grading:
City, St, Zip
Telephone:
Bedrooms: Stories:
# Units:
Email:
State Lic: City Bus Lic:
Property Owner's Name: DRm,i,
New Commercial / Tenant Improvements:
Address: 7 �- S vtj ga-cio
Total Building SF
City, ST, Zip Oz Q Ji��A qll53
Construction Type: Occupancy:
Telephone:
Email:
78495 CALLE
TAMPICO
LA QUINTA, CA 92253
760-777-7000
OFFICE USE ONLY
#
Submittal
Required
Received
Plan Sets
Structural Calcs
Truss Calcs
Title 24 Calcs
Soils Report
Grading Plan (PM10)
Landscape Plan
Subcontractor List
Grant Deed
HOA Approval
School Fees
Burrtec Debris Plan
Planning approval
Public Works approval
Fire approval
City Business License
2
`319
/ � p v VOW
le it e6ow
avzpro 6'
NEW 6.6 0
&Vzoo li.
719
in -V16cc
izi
477"
f r
Rf 1 M�+M1 Yfr
flew 50 f Lv ! ,>I14
aOOA
S u r-b rccao ►�.
Rco ps
7Fcrfs SaAJ4400K
L%
u t,� 6R=
/Ut.Cua%S -COT S
CITY OF QUIN1TA
BUILDING & SAFETY DEPT.
APP OVER
FOR CON TRUCTION
DATE BY
Sa0IALP cl
ctly
fcfz
/P
ar
35611
�2 317
2 -TW 4 �5 VV\ Al�, V'�-Vok`o R19PblA'Q6(, Cllltu�v5
I boo
1 '56 ot
9 8-c>
A/c, t) N Iv
010 6
7
GAtkos t oa a o pawN." 15 0a
5'�0
Tot Po,- C.,ktX. V L^j _- :. "I
� c) VA
1�60 3 4
CITY OF LA QUINTA
BUILDING & SAFETY�7DEPT.
APPROVED
FOR CONST13UCTION
DATE --.By
Jack Lima
From: Daniel Flahive <musichive@icloud.com>
Sent: Tuesday, July 30, 2019 3:02 PM
To: Armando Magallon; Jack Lima
Subject: Information you requested from homeowner @ 78895 Sunbrook Ln., LQ
** EXTERNAL: This message originated outside of the City of La Quinta. Please use proper judgement and caution when
opening attachments, clicking links or responding to requests for information. **
Hello Armando Magallon- The electrical contractor Gary Steven dba "Handy Scotsman" met with you in person this
afternoon and just informed me that you requested the "specs from the manufacturer " on the above ground spa that
we plan to install. Please see attached link ...
https://www.sundancespas.com/en-us/product-list/peyton
I authorize Gary Steven dba "Handy Scotsman" License#796193 to apply for the permit for installation at our home of
electrical for an above ground spa.
Any questions please call me at my cell#(760)835-9766 Best time to call is anytime after 10 a.m.
Sincerely, Karen Flahive
Sent from my Wad
6ff0 Sivk,s
5.0 Power Requirements
SundanceO spas are designed to provide optimum
performance and flexibility of use when connected to the
maximum electrical service. If you prefer, your dealer can
perform a minor circuit board modification to allow your spa
to accept an electrical service other than the factory setting.
Note: Refer to page 53 for circuit board configuration details or contact
your authorized Sundance dealer.
North- • • • •5/Tacoma
1 -Pump Convertible Models (60 Hz)
120V/15A* 240V/30A* 240V/40A**
Circuit Breaker: 15A, 1-Pole 30A, 2-Pole 40A, 2-Pole
Number of Wires: 3 (15A GFCI 4 (Hard Wire 4 (Hard Wire
Cord US Only) Only)
Only*)
Frequency: 60 Hz 60 Hz 60 Hz
Current Draw: 12A 20A 31 A
* In 15A/30A configuration, the heater will not operate while the jets
pump is running in high speed. The factory setting is 120V115A.
** In 40A configuration, the heater will overate while the jets pump is
running in high speed.
**CAUTION: (For a 4-wire 240 VAC Heater Operation): Make
certain wires are connected exactly as shown in Figure D (page 16)
before applying power. Failure to do so will result in damage to the
circuit board and/or related components and void the manufacturer's
warranty.
240V/40A* 240V/50A** 240V/60A***
Circuit Breaker (2-Pole): 40A 50A 60A
Number of Wires: 3 3 3
Frequency: 60 Hz 60 Hz 60 Hz
Current Draw: 26A 36A 45A
* In 40A configuration, the heater will no while either jets
pump is running in high speed. Note: pump 2 runs only in high
speed.
** In 50A configuration, the heater will -not operate while both jets
pumps are running in high speed. This is the factory setting.
Note: pump 2 runs only in high speed.
*** In 60A configuration the heater will operate while both jets pumps
are running in high speed.
Page 12
6,F0 5"is
6.0 Electrical Wiring Instructions
IMPORTANT NOTICE: The electrical wiring of this spa
must meet the requirements of the National Electrical Code/ Aii
USA (NEC) and/or any applicable state or local codes. The
electrical circuit must be installed by a qualified electrician and approved
by a local building/electrical inspection authority.
Convertible 120/240V Denali/Prado/Prado 5/Tacoma Models
Only:
iL DANGER: TO DECREASE THE RISK OF SHOCK,
PRODUCT DAMAGE OR ELECTRICAL FIRE.
120V "Plug-in" Operation: This spa must operate on the supplied 10
foot (3m) 120V GFCI cord at its original length or must be hard -wired
for longer runs. NEVER USE AN EXTENSION CORD FOR ANY
REASON!
Convertible 120/240V Heater Operation: The included 120V GFCI
cord must be discarded for 240V heater operation. This spa must
be hard -wired. Supplying power to either configuration above
which is not in accordance with these instructions will void both the
independent testing agency listing and the manufacturer's warranty.
2. Dedicated 240V Edison, McKinley, Peyton, Ramona Models:
This spa must be permanently connected (hard -wired) to the power
supply. No plug-in connections or extension cords are to be used
in conjunction with the operation of this spa. Supplying power to
the spa which is not in accordance with these instructions will void
both the independent testing agency listing and the manufacturer's
warranty.
3. The power supplied to this spa must be a dedicated circuit with no
other appliance 9o?,lights sharing the power provided by the circuit.
4. To determine the current, v2ltage and wire size required, refer to
Section 5.0 "Power Requirements" (page 12).
• Wire size must be appropriate per NEC and/or local codes.
• The spa controller's terminal block will accept a maximum wire size
of 6 AWG. . N
5. The electrical supply for,this product must include a suitably rated
switch or circuit breaker to open all ungrounded supply conductors
to comply with Section 422-20 of the National Electrical Code/USA,
ANSI/NFPA 70. The disconnecting means must be readily accessible
to the spa's occupant but installed at least 5 feet (1.5m) from spa
water.
6. The electrical circuit supplied for the spa must include a suitable
ground fault circuit interrupter (GFCI) as required by NEC Article
680-42.
Page 13
MO Siti,s
7. The electrical supply for this product must include a suitably rated
isolating switch and circuit breaker to comply with local electrical
regulations. This RCD/GFCI circuit breaker must be installed at the
power supply in the house electrical box.
8. To gain access to the spa's power terminal block, remove the screws
securing the cabinet panel on the side of the spa under the control
panel. Then remove the four control box door screws and door
(Figures A-B, pages 14-15).
9. Select the power supply inlet you want to use (Figure A). Feed power
cable to control box, then install it through the large opening provided
in the bottom side of the box.
10. Connect wires, color to color, on terminal blocks T131 and T133
(Figure C, page 15). TIGHTEN SECURELY! All wires must be
hooked up securely or damage could result.
11. Install control box door and screws and reinstall the cabinet side
panels.
Figure A
Equipment Area
Note: Equipment location (such as pumps, CLEARRAYO
system, drain, heater etc.) varies by model.
1.
Control Box
7.
CLEARRAY (Ultraviolet) Water
2.
Power Supply Inlet(s)
g.
Purification System
CLEARRAY (Ultraviolet) Water
3.
e Pump
Purification System Ballast
4.
Heat
Heaterr
g.
Control Panel
5.
Pump Drain Plugs
10
Optional SmartTubT"" System
6.
1-Speed Pump
11.
Bridge (Optional for SmartTub System)
Page 14
MO Sys
Figure B
Control Box
1. Main Terminal Block
2. Bonding Lug
3. Power wires entrance
(Electrical fitting and conduit must be installed)
Figure C Connections
(North American 60 Hz
240 VAC Connection Models)
/
li9s
/
I
TB1 I
/
I
\
T..J,. 7 -I O - i
3
1
OO
00
B
0
0
0
00
0
Re d
Black
0
0
0®�
0
0 a
®�
eK
I�B3
—
TB1
I GreerI
I
I
I
l
I
I
I
I
I
I
I
I
Page 15
6,F0 S".�z
Figure D
(North American 60 Hz
120/240 VAC Convertible Models)
I
TB1 ,
� � I
1 �
OO a C IORI 00 p I
WI1
I G n I
I ,
I ,
I
i 1
� 1
-_ ,
120 VAC 3-Wire connection 60 Hz
't DO — TB1
I
1 ,
I
1 ,
1 ,
240 VAC 4-Wire connection 60 Hz
120V 3-WIRE CONNECTION
------------- - ------------ - ---- 120V 120V
120V 120V
J22 240V
0 --
240V
D �
J22
_- O c BLK '
0
e WF-4T
0 A
TB1 O GRN
-------------------------------
240V 4-WIRE CONNECTION# 120v 120V
� :J37. .[53 120V 120V
o � O t3
i J22 240V
2
WHT# 40V ;
0 c BLK ; J22
1
®0� 0 e RED#
TB1e GRN--------------------------------
Jumper Wires
FROM
TO
J37
J36
J51
J46
J59
J41
J33
J47
J22
2 jumpers
Jumper Wires
FROM
TO
J37
J38
J51
J46
J59
J53
J33
J47
J22
1 jumper
CAUTION: (FOR A 4-WIRE 240 VAC HEATER
OPERATION.) The jumper at location J22 must be changed
from a 120V to a 240V configuration. Make sure to connect
the wires as shown at TB1, for a 240V connection, before
applying power. Jumper wires MUST be changed. Failure to
follow these steps will result in damage to the circuit board
and/or related components and void the manufactures
warranty.
Page 16