Loading...
BMCH2019-031878-495 CALLE TAMPICO Ct 0 D XP LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Permit Type/Subtype: MECHANICAL/ Application Number: BMCH2O19-0318 Property Address: 48147 CALLE SERANAS APN: 646110034 Application Description: GILTON / HVAC CHANGEOUT Property Zoning: Application Valuation: $10,000.00 n Applicant: U ALL VALLEY AIR 81300 AVENIDA ALAMITOS AUG 0 6 2019 INDIO, CA 92201 P ID CITY OF LA QUINTA DESIGN & DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C20 License No.: 4 OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ, C.). Lender's Name: Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 8/6/2019 Owner: Gilton Terry & Kathleen 48147 CALLE SERANAS LA QUINTA, CA 92253 Contractor: ALL VALLEY AIR 81300 AVENIDA ALAMITOS INDIO, CA 92201 (760)773-3629 Llc. No.: 859431 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the k for which this permit is issued. dgMI have and will maintain workers' compensation insurance, as required by S cti 00 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: fALLS LAKE FIRE AND CASUALTY COMPANY Policy Number: FLA011312 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 37 of the Labor Code, I shall forthwith comply with (hose provisions. y , e " 4 p WARNING: FAILURE TO SECURE WORKERICOMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above - mentioned roperty for inspection purposes. SOMApplicantorA Date: 8/6/2019 Application Number: BMCH2019-0318 Property Address: 48147 CALLE SERANAS APN: 646110034 Application Description. GILTON / HVAC CHANGEOUT Property Zoning: Application Valuation: $10,000.00 Applicant: ALL VALLEY AIR 81300 AVENIDA ALAMITOS INDIO, CA 92201 Owner: Gilton Terry & Kathleen 48147 CALLE SERANAS LA QUINTA, CA 92253 Contractor: ALL VALLEY AIR 81300 AVENIDA ALAMITOS INDIO, CA 92201 (760)773-3629 Llc. No.: 859431 Detail: HVAC CHANGE OUT - 14 SEER/80 AFUE SPLIT SYSTEM R-8 DUCT WORK REPLACEMENT. CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. PER 2016 CALIFORNIA BUILDING CODES. INFORMATIONFINANCIAL DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM 101-0000-42402 0 $40.02 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM PC 101-0000-42600 0 $80.05 Total Paid for CHANGEOUT: $120.07 DESCRIPTION ACCOUNT QTY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $101.40 Total Paid for PERMIT ISSUANCE: $101.40 DESCRIPTION ACCOUNT QTY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 ecry Qai#tra — cr.a� .f d•� urscia' — PERMIT # PLAN LOCATION: Project Address: 1 /p Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: Applicant Name: 1 Address: City, ST, Zip:Irfi , -'j Telephone::�TA a Email: l v 0�_ 1, aC Sg Gj Jvjaluation of Project $ 01b v Contractor Name: I New SFD Construction: Address: `.- ^'# 2I Conditioned Space 7h Iu SF City, St, zipoakm Garage ! SF Telephone: _ Patio/Porch SF Email: V V GL� a4iai Fire Sprinklers SF State Lic: City Bus Lic: ' Arch/Eng Name: Construction Type: A Occupancy: Address: Grading: G City, St, Zip Telephone: G' Bedroom ldck Stories I#Units: V d C', Email: State Lic: (A City Bus Lic: Property Owner's Name: New Commercial / Tenant Improvements: Address:14 ,L 14 6 ` 9— ANULCal Total Building SF City, ST, Zip I (k_ &\) 1�Atkc C ()�, " 22 S eZ,, Construction Type: 14 Occupancy: �n Telephone: -- — 3 2 Email: 61 t l\1CA I G U 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 CERTIFICATE OF COMPLIANCE Alterations to Space Conditioning Systems (formerly CF-IR-ALT HVRC) Project Name: Kathleen Gilton I Date Prepared: CF1R-ALT-02-E (Page 1 of 3) 2019-08-05 A. General Information CF111-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF1R-ALT-02 document for each dwelling unit. 01 Project Name Kathleen Gilton 02 Date Prepared 2019-08-05 03 Project Location 48147 Calle Seranas 04 Building Type Single family 05 CA City La Quinta 06 Dwelling Unit Name Kathleen Gilton 07 Zip Code 92253 08 Dwelling Unit Conditioned 2100 Floor Area (ftZ) Number of Space 09 Climate Zone 15 10 Conditioning (SC) Systems in 1 this Dwelling Unit: B. Space Conditioning (SC) System Information 01 02 03 04 05 06 07 08 09 10 Is the SC Installing a SC System SC System CFA served system a refrigerant Installing new SC Installing Installing Installing Identification or Location or Area by this SC ducted containing system more than 40 entirely new entirely new Name Served System (ft) system? component? components? feet of ducts? duct system? SC system? Alteration Type Entirely new or System 1 Location 1 2100 Yes Yes Yes Yes Yes Yes complete replacement space conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)Miib) Registration Number: 219-A020173883A-000-000-0000000-0000 This section does not apply to this project. Registration Date/Time: 2019-08-05 12:33:39 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-08-05 12:31:38 Schema Version: rev 20180426 CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E Alterations to Space Conditioning Systems (formerly CF-IR-ALT HVAC) (Page 2 of 3) D. Altered Space Conditioning System (Sections 150.2(b)lE and F) This section does not apply to this project. E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150:2(b)Mia and 150.2(b)lE, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C) 01 02 03 04 05 06 07 08 09 10 11 Heating Cooling System Heating Minimum Cooling Minimum Required Identification or Heating System Altered Heating Efficiency Efficiency Cooling Altered Cooling Efficiency Efficiency Thermostat New Duct Name Type Component Type Value System Type Component Type Value Type R-Value Annual Fuel System 1 Central gas All new heating Utilization 80 Central split All new cooling SEER 14 SetbackTher R 8 furnace components Efficiency AC components mostat (AFUE) Required Documentation: CF211-MCH-01-E -:Space Conditioning Systems - Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16) CF2R and CF3R-MCH-20-H Duct Leakage Test required - Leakage rate compliance: <= 5%. CF211 and CF3R-MCH-22 Fan Efficacy CF2R and CBR-MCH-23 Airflow Rate Verification Compliance: Fan Efficacy <= 0.58 W per cfm and System Airflow >= 350 cfm per ton. Alternative Compliance: CF2R and CF3R-MCH-28 Return Duct'iDesign verification is an alternative to MCH-22 and MCH-23 verification. CF2R and CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). Exceptions: Heating -only systems are exempt from the 0.58 W per cfm and 350 cfm per ton requirements. Note: An "entirely new or replacement duct system" means at least 75% of the duct system is new duct material, and up to 25% may consist of reused parts from the dwelling unit's existing duct system (e.g., registers, grilles, boots, air handler, coil, plenums, duct material) if the reused parts are accessible and can be sealed to prevent leakage Registration Number: 219-A020173883A-000-000-0000000-0000 Registration Date/Time: 2019-08-05 12:33:39 HERS Provider: CalCERTS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-08-05 12:31:38 Schema Version: rev 20180426 CERTIFICATE OF COMPLIANCE CFIR-ALT 02-E Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC) (Page 3 of 3) Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Compliance documentation Is accurate and complete. Documentation Author Name: Documentation Author Signature: /� �� I� L/(/CccS`nyre McIntyre, Amanda manna Company: Signature Date: All Valley Air 2019-08-05 12::33:39 Address: CEA/ HERS Certification Identification (if applicable): 77899 Wolf Road City/State/Zip: Phone: Palm Desert CA 92211 760-773-3629 Responsible,Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Complirance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building,:and made available tothe enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Responsible Designer Signature: a /� McIntyre, Amanda ntan a L5TfcJnNre Company: Date Signed: All Valley Air 2019-08-05 12:33:39 Address: License: 77899 Wolf Road 859431 City/State/Zip: Phone: Palm Desert CA 92211 760-773-3629 Easy to Verify 0 at CaICERTS.com Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 219-A020173883A-000-000-0000000-0000 Registration Date/Time: 2019-08-05 12:33:39 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-08-05 12:31:38 Schema Version: rev 20180426 All Valley Air 77899 Wolf Road, Suite 109 Palm Desert, CA 92211 (760)773-3629 I Name / Address I Kathleen Gilton 49147 Calle Seranas La Quinta, CA. 92253 Estimate Date Estimate # 7/29/2019 543 Project Description Qry Rate Total Warranty Information: 10 Year Compressor. Life Time Heat Exchanger. 10 Year Major Components. 10 Year Coils. 1 Year Labor. Deposit already paid. 1 -2,500.00 -2,500.00 Thank you for your business! Check out our website at www.cvallvalieyair.com. CA Lic #859431 Total $8,00 4 . Page 2 All Valley Air 77899 Wolf Road, Suite 109 Palm Desert, CA 92211 (760) 773-3629 Name / Address Kathleen Gilton 48147 Calle Scranas La Quinta, CA. 92253 Estimate Date Estimate # 7/29/2019 543 Project Description Qty Rate Total Furnish and install 2-EA. 14 IN. X 14IN. return ceiling boxes with l 10,900,00 10.900.00 Bar type grills, 4-ea. 6x10 ceiling boxes, remove furnace to install 2-in. under furnace filter rack, install sheetmetal platform cap, install new R-6 duct system thru out the house, move the condensing unit 3 ft. down the wall. Fumish and install I -ea. Amana Model ASX140481, 14.0 SEER, 4.0'Fon condensing unit together with I-ea.Amana Model AMS80804BX, 80% AFUE, 80,000 BTUH up flow furnace with I -ea. Aspen Model CE48175L004, 4.0 Ton up flow evaporator coil mounted in the same location as the existing furnace and coil. "This price includes installation labor, material removal of the old equipment from the job sit, installation of customer supplied Nest thermostat and sales tax. Exclusions: All ceiling supply and return grills except the 2-ea. 14x14 grills described in the above price are being installed by the remodel contractor. Note : Any unforeseen repair costs will he done only with the owners approval, Thank you for your business! Check out our website at www.cvallvallcyair.com. CA Lic #859431 Tot 1 r Signature Page 1