BMCH2019-031878-495 CALLE TAMPICO Ct 0 D XP
LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Permit Type/Subtype: MECHANICAL/
Application Number: BMCH2O19-0318
Property Address: 48147 CALLE SERANAS
APN: 646110034
Application Description: GILTON / HVAC CHANGEOUT
Property Zoning:
Application Valuation: $10,000.00 n
Applicant: U
ALL VALLEY AIR
81300 AVENIDA ALAMITOS AUG 0 6 2019
INDIO, CA 92201 P ID
CITY OF LA QUINTA
DESIGN & DEVELOPMENT DEPARTMENT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9
(commencing with Section 7000) of Division 3 of the Business and Professions Code, and
my License is in full force and effect.
License Class: C20 License No.: 4
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any
structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the
alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that he
or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to
construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State
License Law does not apply to an owner of property who builds or improves thereon,
and who contracts for the projects with a contractor(s) licensed pursuant to the
Contractors' State License Law.).
(_) I am exempt under Sec. B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ, C.).
Lender's Name:
Lender's Address:
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 8/6/2019
Owner:
Gilton Terry & Kathleen
48147 CALLE SERANAS
LA QUINTA, CA 92253
Contractor:
ALL VALLEY AIR
81300 AVENIDA ALAMITOS
INDIO, CA 92201
(760)773-3629
Llc. No.: 859431
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the k for which this permit is issued.
dgMI have and will maintain workers' compensation insurance, as required by
S cti 00 of the Labor Code, for the performance of the work for which this permit is
issued. My workers' compensation insurance carrier and policy number are:
Carrier: fALLS LAKE FIRE AND CASUALTY COMPANY Policy Number: FLA011312
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 37 of the Labor Code, I shall forthwith
comply with (hose provisions. y , e " 4 p
WARNING: FAILURE TO SECURE WORKERICOMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit issued
as a result of this application , the owner, and the applicant, each agrees to, and shall
defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not
commenced within 180 days from date of issuance of such permit, or cessation of work
for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the above -
mentioned roperty for inspection purposes.
SOMApplicantorA
Date: 8/6/2019
Application Number:
BMCH2019-0318
Property Address:
48147 CALLE SERANAS
APN:
646110034
Application Description.
GILTON / HVAC CHANGEOUT
Property Zoning:
Application Valuation:
$10,000.00
Applicant:
ALL VALLEY AIR
81300 AVENIDA ALAMITOS
INDIO, CA 92201
Owner:
Gilton Terry & Kathleen
48147 CALLE SERANAS
LA QUINTA, CA 92253
Contractor:
ALL VALLEY AIR
81300 AVENIDA ALAMITOS
INDIO, CA 92201
(760)773-3629
Llc. No.: 859431
Detail: HVAC CHANGE OUT - 14 SEER/80 AFUE SPLIT SYSTEM R-8 DUCT WORK REPLACEMENT. CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR
TO FINAL INSPECTION. PER 2016 CALIFORNIA BUILDING CODES.
INFORMATIONFINANCIAL
DESCRIPTION ACCOUNT QTY AMOUNT
BSAS SB1473 FEE
101-0000-20306 0 $1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HVAC CHANGEOUT - SPLIT -SYSTEM
101-0000-42402
0
$40.02
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HVAC CHANGEOUT - SPLIT -SYSTEM PC
101-0000-42600
0
$80.05
Total Paid for CHANGEOUT: $120.07
DESCRIPTION ACCOUNT
QTY
AMOUNT
PERMIT ISSUANCE 101-0000-42404
0
$101.40
Total Paid for PERMIT ISSUANCE: $101.40
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RECORDS MANAGEMENT FEE
101-0000-42416
0
$10.00
Total Paid for RECORDS MANAGEMENT FEE: $10.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
ecry Qai#tra
— cr.a� .f d•� urscia' —
PERMIT #
PLAN LOCATION:
Project Address: 1 /p
Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech
APN #:
Applicant Name: 1
Address:
City, ST, Zip:Irfi ,
-'j
Telephone::�TA a
Email: l v 0�_ 1, aC Sg Gj
Jvjaluation of Project $ 01b
v
Contractor Name:
I
New SFD Construction:
Address:
`.-
^'#
2I
Conditioned Space
7h
Iu SF
City, St, zipoakm
Garage
! SF
Telephone:
_
Patio/Porch
SF
Email: V
V GL� a4iai
Fire Sprinklers
SF
State Lic: City Bus Lic: '
Arch/Eng Name:
Construction Type: A Occupancy:
Address:
Grading: G
City, St, Zip
Telephone: G'
Bedroom ldck
Stories
I#Units: V d C',
Email:
State Lic: (A City Bus Lic:
Property Owner's Name:
New Commercial / Tenant Improvements:
Address:14 ,L 14 6 ` 9— ANULCal
Total Building SF
City, ST, Zip I (k_ &\) 1�Atkc C ()�, " 22 S eZ,,
Construction Type:
14 Occupancy: �n
Telephone: -- — 3 2
Email: 61 t l\1CA I G
U 78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
CERTIFICATE OF COMPLIANCE
Alterations to Space Conditioning Systems (formerly CF-IR-ALT HVRC)
Project Name:
Kathleen Gilton I Date Prepared:
CF1R-ALT-02-E
(Page 1 of 3)
2019-08-05
A. General Information
CF111-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one
CF1R-ALT-02 document for each dwelling unit.
01
Project Name
Kathleen Gilton
02
Date Prepared
2019-08-05
03
Project Location
48147 Calle Seranas
04
Building Type
Single family
05
CA City
La Quinta
06
Dwelling Unit Name
Kathleen Gilton
07
Zip Code
92253
08
Dwelling Unit Conditioned
2100
Floor Area (ftZ)
Number of Space
09
Climate Zone
15
10
Conditioning (SC) Systems in
1
this Dwelling Unit:
B. Space Conditioning (SC) System Information
01
02
03
04
05
06
07
08
09
10
Is the SC
Installing a
SC System
SC System
CFA served
system a
refrigerant
Installing new SC
Installing
Installing
Installing
Identification or
Location or Area
by this SC
ducted
containing
system
more than 40
entirely new
entirely new
Name
Served
System (ft)
system?
component?
components?
feet of ducts?
duct system?
SC system?
Alteration Type
Entirely new or
System 1
Location 1
2100
Yes
Yes
Yes
Yes
Yes
Yes
complete
replacement space
conditioning system
C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)Miib)
Registration Number: 219-A020173883A-000-000-0000000-0000
This section does not apply to this project.
Registration Date/Time: 2019-08-05 12:33:39
HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-08-05 12:31:38
Schema Version: rev 20180426
CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E
Alterations to Space Conditioning Systems (formerly CF-IR-ALT HVAC) (Page 2 of 3)
D. Altered Space Conditioning System (Sections 150.2(b)lE and F)
This section does not apply to this project.
E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150:2(b)Mia and 150.2(b)lE, F)
This section does not apply to this project.
F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C)
01
02
03
04
05
06
07
08
09
10
11
Heating
Cooling
System
Heating
Minimum
Cooling
Minimum
Required
Identification or
Heating System
Altered Heating
Efficiency
Efficiency
Cooling
Altered Cooling
Efficiency
Efficiency
Thermostat
New Duct
Name
Type
Component
Type
Value
System Type
Component
Type
Value
Type
R-Value
Annual Fuel
System 1
Central gas
All new heating
Utilization
80
Central split
All new cooling
SEER
14
SetbackTher
R 8
furnace
components
Efficiency
AC
components
mostat
(AFUE)
Required Documentation:
CF211-MCH-01-E -:Space Conditioning Systems
- Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16)
CF2R and CF3R-MCH-20-H Duct Leakage Test required
- Leakage rate compliance: <= 5%.
CF211 and CF3R-MCH-22 Fan Efficacy
CF2R and CBR-MCH-23 Airflow Rate Verification
Compliance: Fan Efficacy <= 0.58 W per cfm and System Airflow >= 350 cfm per ton.
Alternative Compliance: CF2R and CF3R-MCH-28 Return Duct'iDesign verification is an alternative to MCH-22 and MCH-23 verification.
CF2R and CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15).
Exceptions:
Heating -only systems are exempt from the 0.58 W per cfm and 350 cfm per ton requirements.
Note: An "entirely new or replacement duct system" means at least 75% of the duct system is new duct material, and up to 25% may consist of reused parts from the dwelling
unit's existing duct system (e.g., registers,
grilles, boots, air handler, coil, plenums, duct material) if the reused parts are accessible and can be sealed to prevent leakage
Registration Number: 219-A020173883A-000-000-0000000-0000 Registration Date/Time: 2019-08-05 12:33:39 HERS Provider: CalCERTS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-08-05 12:31:38
Schema Version: rev 20180426
CERTIFICATE OF COMPLIANCE CFIR-ALT 02-E
Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC) (Page 3 of 3)
Documentation Author's Declaration Statement
1. 1 certify that this Certificate of Compliance documentation Is accurate and complete.
Documentation Author Name:
Documentation Author Signature: /� �� I�
L/(/CccS`nyre
McIntyre, Amanda
manna
Company:
Signature Date:
All Valley Air
2019-08-05 12::33:39
Address:
CEA/ HERS Certification Identification (if applicable):
77899 Wolf Road
City/State/Zip:
Phone:
Palm Desert CA 92211
760-773-3629
Responsible,Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer).
3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Complirance conform to the
requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
5. 1 will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building,:and made available tothe enforcement agency for all applicable
inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy.
Responsible Designer Name:
Responsible Designer Signature: a /�
McIntyre, Amanda
ntan a L5TfcJnNre
Company:
Date Signed:
All Valley Air
2019-08-05 12:33:39
Address:
License:
77899 Wolf Road
859431
City/State/Zip: Phone:
Palm Desert CA 92211 760-773-3629
Easy to Verify 0
at CaICERTS.com
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in no way implies
Registration Provider responsibility for the accuracy of the information.
Registration Number: 219-A020173883A-000-000-0000000-0000
Registration Date/Time: 2019-08-05 12:33:39
HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-08-05 12:31:38
Schema Version: rev 20180426
All Valley Air
77899 Wolf Road, Suite 109
Palm Desert, CA 92211
(760)773-3629
I Name / Address I
Kathleen Gilton
49147 Calle Seranas
La Quinta, CA. 92253
Estimate
Date
Estimate #
7/29/2019
543
Project
Description
Qry
Rate
Total
Warranty Information:
10 Year Compressor.
Life Time Heat Exchanger. 10 Year Major Components.
10 Year Coils.
1 Year Labor.
Deposit already paid.
1
-2,500.00
-2,500.00
Thank you for your business! Check out our website at www.cvallvalieyair.com. CA Lic
#859431 Total $8,00 4 .
Page 2
All Valley Air
77899 Wolf Road, Suite 109
Palm Desert, CA 92211
(760) 773-3629
Name / Address
Kathleen Gilton
48147 Calle Scranas
La Quinta, CA. 92253
Estimate
Date
Estimate #
7/29/2019
543
Project
Description
Qty
Rate
Total
Furnish and install 2-EA. 14 IN. X 14IN. return ceiling boxes with
l 10,900,00
10.900.00
Bar type grills, 4-ea. 6x10 ceiling boxes, remove furnace to install
2-in. under furnace filter rack, install sheetmetal platform cap, install
new R-6 duct system thru out the house, move the condensing unit 3
ft. down the wall.
Fumish and install I -ea. Amana Model ASX140481, 14.0 SEER,
4.0'Fon condensing unit together with I-ea.Amana Model
AMS80804BX, 80% AFUE, 80,000 BTUH up flow furnace with
I -ea. Aspen Model CE48175L004, 4.0 Ton up flow evaporator coil
mounted in the same location as the existing furnace and coil.
"This price includes installation labor, material removal of the old
equipment from the job sit, installation of customer supplied Nest
thermostat and sales tax.
Exclusions:
All ceiling supply and return grills except the 2-ea. 14x14 grills
described in the above price are being installed by the remodel
contractor.
Note :
Any unforeseen repair costs will he done only with the owners
approval,
Thank you for your business! Check out our website at www.cvallvallcyair.com. CA Lic
#859431
Tot 1
r
Signature
Page 1