Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BPLB2019-0116
78-495 CALLE TAMPICO T4t!/ D "i-i�11[+tC[I LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Permit Type/Subtype: BUILDING RESIDENTIAL/REMODEL Application Number: BPLB2019-0116 Property Address: 54040 AVENIDA DIAZ APN: 774201029 Application Description: PENDLETON / PROPANE TANK W/ ENCLOSURE, GAS LINE, POOL Property Zoning: HEATER Application Valuation: $3,500.00 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 8/27/2019 Owner: DAVID ROSS & BECKY ANN PENDLETON 54040 AVENIDA DIAZ LA QUINTA, CA 92253 Applicant: D Contractor: B CONSTRUCTION INC B CONSTRUCTION INC P O BOX 10758 AUG 2 % 2019 P O BOX 10758 PALM DESERT, CA 92255 PALM DESERT, CA 92255 CITY OF LA QUINTA (760)275-6698 DESIGN & DEVELOPMENT DEPARTMENT Llc. No.: 889388 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: A. B License No.: 889388 Oate� �� Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following'reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of for which this permit is issued. have and will maintain workers' compensation insurance, as required by or Section 37 0 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: 5I6TE COMPENSATIM,t4$U139NCE FUND Policy Number: 9032264 _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: 21 Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalfthis application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance ofthis permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above - mentioned property for inspection purposes. Dater Signature (Applicant or Agent) Date: 8/27/h19 Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: B CONSTRUCTION INC P 0 BOX 10758 PALM DESERT, CA 92255 BPLB2019-0116 Owner: 54040 AVENIDA DIAZ DAVID ROSS & BECKY ANN PENDLETON 774201029 54040 AVENIDA DIAZ PENDLETON / PROPANE TANK W/ ENCLOSURE, GAS LINE, POOL HEATER LA QUINTA, CA 92253 $3,500.00 Contractor: B CONSTRUCTION INC P 0 BOX 10758 PALM DESERT, CA 92255 (760)275-6698 Llc. No.: 889388 Detail: NEW PROPANE TANK + 165LF OF 1-1/4" GAS LINE + NEW POOL HEATER AT REAR YARD + 15LF OF 4' TALL GARDEN WALL TANK ENCLOSURE [ANGELUS S-1.OLQ STANDARD]. 2016 CALIFORNIA BUILDING CODES. DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES, FIRST 20 101-0000-42403 0 $26.68 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES, FIRST 20 PC 101-0000-42600 0 $26.68 Total Paid for ELECTRICAL: $53.36 DESCRIPTION ACCOUNT CITY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $101.40 Total Paid for PERMIT ISSUANCE: $101.40 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 1-4 OUTLETS 101-0000-42401 0 $13.34 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 1-4 OUTLETS PC 101-0000-42600 0 $26.68 Total Paid for PLUMBING FEES: $40.02 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 -- PERMIT # PLAN LOCATION: Project Address: {� .— l Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: -? J `l ^ Zd I -- Z i ky->, YA-V-- Nell" f) Applicant Name: /42�yo ((oS I VV W Address: OC) City, ST, Zip: �o j Telephone: Email: Valuation of Project $ Contractor Name: KD— BUG 0 New SFD Construction: Address: po b Conditioned Sp e SF City, St, Zip 5 ,F ti I zZ r Garage SF TelephoneL,] r _ / c) Patio/Porch SF Email: IS C-oti`D pp, C, �� 7t1 �o Fire Sp ir►f- SF State Lic: (qRCity Bus Lic: NN Arch/Eng Name: 1. Construction Type: Occupancy: Address: �� �4- Grading: City, St, Zip I Telephone: Bedrooms: Stories: # Units: Email: State Lic: City Bus Lic: 771 Property Owner's Name: Iv\ e New Commercial / Tenant Improvements: Address: S d e POC*3 S f Total Building SF City, ST, Zip SPrA- Construction Type: Occupancy: Telephone: N Email: 78495 CALLE TAMPICO LA QU I NTA, CA 92253 760-777-7000 8/27/2019 Gmail - Diaz propane tank B Howard <bconstructioninc@gmail.com> Diaz propane tank 2 messages Bill Howard <bconstructioninc@gmail.com> Mon, Aug 26, 2019 at 11:43 AM To: drpendleton50@gmail.com, becky-pendleton@shaw.ca Hi The permit for the propane wall, gas line and heater is ready to be issued from the city. All they need is a email/letter from you, the property owner, stating you are approving the work to be done. Mention the propane tank, wall, gas line and heater in your response. If you can email me something to that effect, I'll print it and take it in when I go pick up permit and pay the fees later this week. . Thanks. Bill David Pendleton <drpendleton50@gmail.com> To: Bill Howard <bconstructioninc@gmail.com> Hi Bill.... attached as requested. Let me know if you need anything else City of La Quinta Permits Department 54040 Avenida Diaz La Quinta Tue, Aug 27, 2019 at 9:17 AM Please be advised we are the registered owners of the above noted property. Our contractor Bill Howard is authorized on our behalf to obtain the necessary permit(s) to construct a block wall and install a propane tank, gas line and pool heater at the house. We approve this work to be done. Thank you. David Pendleton 250-588-1560 Becky Pendleton 250-588-1560 [Quoted text hidden] https:Hmail.google. corn/mai1/u/0?ik=4d 1 c09793a&view=pt&search=a1 l &permthid=thread-f%3A1642956052872881116&simpl=msg-f0/.3A16429560528... 1 /1 Ste! v 44 mac.)!; e!;,20 l I - o! 1 �, CIS©F LAQUINTA NG DIVISION REVIEWED POR CODE COMPLIANCE DATE ll BY 7F �Qo?4NE -rh�11t + i Cj[.F-Eri3G�5c�1r� 1 gf- DIF E)U51"Ji cote 0mc-c- COPY 8/19/2019 Google Maps https://www.google.com/maps/@33.6556712,-116.3155325,11 m/data=!3m 1 ! 1 e3 1 /1 rJanqy-.,,,, m w 0 0 z INSTALLATION AND OPERATION MANUAL Jandy Pro Series JXi TM Gas -Fired Pool and Spa Hea Models 200, 260, 40� FOR YOUR SAFETY. This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exists. In the event no such state or local requirement exists, the installer or maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in property damage, personal injury, or death. Improper installation and/or operation can create carbon monoxide gas and flue gases which can cause serious injury, property damage, or death. For indoor installations, as an additional measure of safety, Zodiac Pool Systems, Inc. strongly recommends installation of suitable carbon monoxide detectors in the vicinity of this appliance and in any adjacent occupied spaces. Improper installation and/or operation will void the warranty. -Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS • Immediately switch off main gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Jandy Pro Series, JXi'" Gas -Fired Pool & Spa Heater Installation & Operation Manual ENGLISH Page 15 Section 4. Gas Connections Gas piping installation must be in accordance with the latest edition of ANSI Z223.1 and all local codes. In Canada, the installation must be in accordance with CAN/ CSA B149.1 and all local codes that apply. The heater must be isolated from the gas supply piping system by closing the individual manual shut off valve during any pressure testing of the gas supply piping system at test pressure greater than or equal to 1/2 psi (3.50a). CAUTION Permanent damage to the gas valve will occur if the installation procedures are not followed correctly. 4.1 Supply Gas Requirements © WARNING The JX pool and spa heaters are designed for use .v; 6 :^er natural gas or LP gas. Check the rating plate on the front a`he combustion chamber to be sure that the heater is designed to uss the type of gas being supplled. CONVERTING THIS HEATER FOR USE WITH ANY OTHER FUEL TYPE IS NOT RECOMMENDED i BUT, WHEN NECESSARY, SHOULD ONLY BE PERFORMED BY A LICENSED AND QUALIFIED PROFESSIONAL, AND ONLY AFTER CONTACTING ZODIAC FOOL SYSTEMS FOR THE PROPER INSTRUCTIONS AND CONVERSION KIT All questions should be directed to the Zodiac customer service center at 1-800-822-7933 Natural Gas at 1050 btu per cubic foot 3/4" 1 "1 4" 1-1/2" Model NG LP NG LP NG __�_ILP'l NG LP NG 'LP JXi400 5 ft 20 ft 30 ft 60 ft 110 ft 260 ft 230 ft 560 ft 600 ft 600 ft JXi260 15 ft 40 ft 60 ft 150 ft 230 ft 590 ft 490 ft 600 ft 600 ft JXi200 30 ft 70 ft 1100 ft + 240 ft 380 ft 600 ft 600 ft • Numbers are for natural gas (0.60 Sp. Gr.) based on 1/2 inch (3.45 kPa) water column pressure drop. Check supply pressure with a manometer, and local code requirements for variations. • Check supply pressure and local code requirements before proceeding with installation. • Consider pipe fittings when determining gas pipe sizing. For every elbow used add three (3) feet to straight pipe length, • Table shows the minimum supply gas pipe size required. Larger pipe size can be used if required by local code or if desired. • It is critical that the incoming gas supply pressure at the heater is within the maximum and minimum pressure requirements. If the range of acceptable supply pressure is not provided, the gas supply system to the heater must be modified to meet pressure requirements. Table 2. Supply Gas Pipe Size Requirements • Refer to Table 2 for correct gas inlet piping length from the gas meter to the heater. • Check the gas meter to make sure it will supply enough Co gas to the heater and any other appliances using the same gas supply, If unsure, contact your local gas utility to confirm. • Install a manual gas shutoff valve outside the heater body for service and safety. Never install the shutoff valve inside the body of the heater. • Install.a sediment trap and union ahead of the gas controls and outside the heater body. See Figure b. • Do not use a restrictive -,as cock. ATTENTION Do not use flexible appliance connectors on any gas connections untess the connector is CSA approved for outdoor installation, and is marked with the BTUH capacity (which must be equal to or greater than the healer rated input) and the type of gas (Natural or LP). Also. any flexible connectors, such as CSST buried underground must be certified for underground installation and meet all applicable codes. Please note, use of flexible connector stilt requires the installation of a sediment trap per NFPA 54. See Figure 6. NOTE: The gas line from the meter is usually larger than the gas valve. Therefore, you will need to reduce connecting pipe as necessary. Make this reduction as close to the heater as possible. Figure 6. Manual Shut-off Valve and Sediment Trap BLOQC CO, IINC. ANGELUS BLOCK MASONRY FENCE WALL SYSTEM! DESIGN CRITERIA: 1. DESIGN CRITERIA PER 2016 CBC 2. ALLOWABLE SOIL BEARING PRESSURE = 1500psf 3. ALLOWABLE SOIL PASSIVE PRESSURE = 150pcf 4. COEFFICIENT OF FRICTION = 0.25, COHESION = Opsf 5 CANTILEVER ACTIVE = 30pcf 6. MASONRY COMPRESSIVE STRENGTH, fm = 1500psi. SPECIAL INSPECTION NOT REQUIRED PER CBC SECTION 1704.2. EXCEPTION 2. 'U' OCCUPANCY. 7. USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE PROJECT SPECIFIC SITE NOTES: 1. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 GRADE 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER. CENTER VERTICAL BARS IN CELLS, 2. JOINT REINFORCEMENT ("LADDER" TYPE) SHALL BE COLD -DRAWN STEEL WIRE CONFORMING TO ASTM A951. PROVIDE MINIMUM 6 INCH LAP SPLICES. 3. STRENGTH OF CONCRETE FOR FOOTINGS = 2500psi ® 28 DAYS, UNLESS OTHERVASE REQUIRED BY SOILS REPORT 4. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS BLOCK PRECISION, SPLIT FACE, BURNISHED, OR SHOTBLAST, WITH OR WITHOUT MORTARLESS HEAD JOINTS (TONGUE -AND -GROOVE). OR ANGELUS BLOCK SLUMPSTONE SHALL BE USED. 5. MORTAR SHALL BE SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS MANUFACTURED BY E-Z MIX INC_, CONFORMING TO PROPORTIONS AND REQUIREMENTS OF ASTM C270, OR SPEC MIX IWR MASONRY MORTAR AS MANUFACTURED BY E-Z MIX INC_ CONFORMING TO PROPERTY REQUIREMENTS OF ASTM C270. 6' to 8' High Site Wall Concentric Spread Footing C o 110mph Wit) Risk Category I 6" Wide CMU UV I1UNAL Wf 6 STD. LAD �5 STD FOR JOINT REINF. AT FIRST CO 6" WIDE (NO GROUT CELL! w/ REINF. 'X' BARS PE SCHEDULE 411 CTR. OF WAI 6. GROUT SHALL CONFORM TO ASTM C476, WITH AN 8-11 INCH SLUMP, AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2000psi. DWLS_ TO M, 7. FIRST COURSE MAY BE WET -SET 1 1/2 INCHES MAX_ WHILE CONCRETE VERT. REINF. IS PLASTIC. 24" MIN. 8. CONCRETE BLOCK SHALL BE LAID IN RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS. F.G. - 9. VERTICAL CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF 40'-0"o.c. OR 20'-0"o.c. IF WALL IS TO BE STUCCO COATED OR MORTAR WASHED 0. GROUT ALL CELLS WITH REINFORCEMENT. 11. INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL FOOTING REINFORCING IS TIED IN PLACE. B. AFTER VERTICAL REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT. 12. FOR TYPICAL FOOTING STEP AND DRAINAGE BLOCK -OUT DETAILS SEE DETAIL SHEET S-5.1. 13. DO NOT PLACE FOOTING WITHIN 5'-0" OF A SLOPE MASONRY FENCE WALL. SCHEDULE 'H' MAX. X BARS 16- LONG GNU 16" LONG CLU 'B' MIN. 6.-0' 'c.c. f4®54"o.c. 1'-11- 6'-8" ~o_G "S'o.c. 2'-1" 7'-4" 2"o.c. "o.c. 2'-3" 8 -0 47o.c_ I #4027"o.c. 1 2 -6" GHL INC. Ak<;'fTECTURF. <Ff IGINEER;IJG 228 East eadina Sc—t . Covim, CA 91723 T: 626.938.1595 F: 626.938.0485 WET -SET FTF COURSE 2-#4 CONT. CONT. CONC ALT_ BENDS PER SCHEDULE DATE SIGNED 9-10-18 S-1.OLQ #16-077