Loading...
BPOL2019-015578-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type/Subtype: Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Twyl 4 4 Q91ot DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT POOL/PRIVATE BPOL2019-0155 53025AVENIDA ALVARADO 774043013 GOFF / POOL AND SPA AT REAR YARD $40,000.00 Applicant: GATTUSO POOL CORPORATION 667 EUGENE ROAD PALM SPRINGS, CA 92264 PD �0 AUG 0 7 2019 CITY OF LA QUINTA DESIGN & DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C53 License No.: 672850 Date: TJ —I--1 7 Contractor OWNER•BUJLDEJ DEC ARATiON I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 8/7/2019 Owner: JASON GOFF 53025 AVENIDA ALVARADO LA QUINTA, CA 92253 Contractor: GATTUSO POOL CORPORATION 667 EUGENE ROAD PALM SPRINGS, CA 92264 (760)327=7592 Llc. No.: 672850 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit Is issued. I have and will maintain workers' compensation insurance, as required by SeOdy 00 of the Labor Code, for the performance of the work for which this permit is iss workers' compensation insurance carrier and policy number are: Carrier: BENCHMARK 1NSQR6NCL CQMPANY — Policy Number: CU5014752 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: 91n -- / —7-Z Applicant WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, Its officers, agents, and employees for any act or omission related to the work being performed under or following Issuance o€this permit. 2. Any permit issued as a result of this applicatian becomes null and void if work is not commenced withlri 180 days from date of issuance of such permit, or cessation of work for 180days will subject permit to cancellation. certify that I have read this application and state that the above Information Is correct. agree to compty with all city and county ordinances and state laws relating to building anstruction, and hereby authorize representatives of this city to enter upon the a bove- n en tion ed property fo r i n sp ecti o n purposes. We* r � � Signature (Appiieant or Agent); Date: 8/7/2019 Application Number: BPOL2019-0155 Property Address: 53025 AVENIDA ALVARADO APN: 774043013 Application Description: GOFF / POOL AND SPA AT REAR YARD Property Zoning: Application Valuation: $40,000.00 Applicant: GATTUSO POOL CORPORATION 667 EUGENE ROAD PALM SPRINGS, CA 92264 Owner: JASON GOFF 53025 AVE NIDA ALVARADO LA QUINTA, CA 92253 Contractor: GATTUSO POOL CORPORATION 667 EUGENE ROAD PALM SPRINGS, CA 92264 (760)327-7592 Llc. No.: 672850 Detail: POOL AND SPA WITH MECHANICAL RELOCATION TO NEW POOL EQUIPMENT LOCATION, ALL AT REAR YARD [DENISE POELTLER ENGINEERING] THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE. SPECIAL INSPECTION FOR SHOTCRETE PLACEMNET AND STRENGTH REQUIRED. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE -PLASTER INSPECTION. 2016 CALIFORNIA BUILDING CODES. FINANCIAL DESCRIPTION INFORMATION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $2.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 DESCRIPTION ACCOUNT CITY AMOUNT CONDENSER/COMPRESSOR 101-0000-42402 0 $40.02 DESCRIPTION ACCOUNT CITY AMOUNT CONDENSER/COMPRESSOR PC 101-0000-42600 0 $26.68 Total Paid for MECHANICAL: $66.70 DESCRIPTION ACCOUNT CITY AMOUNT SWIMMING POOL/SPA 101-0000-42404 0 $200.12 DESCRIPTION ACCOUNT CITY AMOUNT SWIMMING POOL/SPA PC 101-0000-42600 0 $108.87 Total Paid for POOL / SPA: $308.99 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 TOTALS: $392.69 Bin # Permit # City of LA Quanta fl. Cj Ruilding az Safety Division P.Q. Box 1504, 78-495 Cabe Tampico a,VUNQA�DO La.Quanta, CA 92253 - (760)777-7012 -e Building Permit Application and Tracking Sheet Project Address: Owner's Name: Jason Goff A- P. Number. Address: 53025 Avenedia Alvarado Legal Description: Contractor.Gattuso Pool Corporation City, ST, Zip:La Quinta, CA Telephone: Address:667 Eugene Road Project Description: Pool & Spa Construction City, ST, zip:Palm Springs, CA 92264 Concrete Decking Telephone:1-760-327-7592 State Lie. #: C53 - 672850 City Lic. ii:00816 Arch., Engr., Designer. Plying Buttress Addness:72661 Hwy 111 #6 City, ST, zip:Palm Desert, CA 92260 Telephone: 1-760-779=0405 State Lic. #: 33446 Name of Contact Person: Gar Gattuso Construction Type: Occupancy: Project type (circle one): New Add'n Alter Repair Demo Sq. Ft.: # Stories: # Units: Telephone of Contact Person: 1-760-32[7--759 Estimated value of Pmjcct: $4Q 000.00 �# v—'Q K�'i S Ai'PLICANT. DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACMG PERMIT FEES Plan Seta Plan Check submitted Item Amoaat Structural Caies. Reviewed, ready, for correcdow Plan Check Deposit Truss Calcs. Called Contact Person Plan Cheek Balance Tide 24 Cates. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" ! Review, ready for correctious/issue Electrical Subcontactor List Called ContactPerson Plumbing Grant Deed Plans picked up S.M.I. H.Q.A. Approval Plans resubmitted Grading IN ROUSE:- '"' Review; rcady for correctionsAme Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit Issue School Fees Total Permit Fees 4onaso POOL RECEIVED JUL 2 3 2019 CITY OF IA QUINTA DESIGN AND rmici CORPORM10H oPMENT DEPARTMENT &W 8T y S W�i[� POOL CONTRACT MY EUGENE ROAD • PALM SPRIIIGS, CA sa2st (M) 327-7592 • FAX (760) T184920 OWNER: JaWR Gnff PHONE; PAOJECTADDRM: 53025 Avenida Alva(adn-1a Q tlnta - rA..$2253__ 11llIMOAMRBS- POOL, _26' x 61 DEP3ii:_3112, x_S-'. - sPA E x 6— R.A'sRD _'IT" IETs §- 5f'iLLWAY_ Tile --- GENERAL CONSRUMON SP'ECTMCATIONS L (90= Pad Corporation to supply mgkn=W pis cad spomficd aria. 2 Qatum Pool Cwpo sdaa to auppiy layoni pleas, 3. 09Wso Pua1 Corpaasinn to &Udo awfrnming pod =WMSCd= tw►M1s. 4. r3stcusa PW C,grpprsiw to Wioia pool per spproygd fW by aw 5. t noWso Yoe= CMPCr&M to eatcavaaa POOL 6. Gatitmo- to revom arenas wall. 7. N to mpaair taxes V arll. L daitbno Pod CaMorasim to am m 8nm pod cue on do day of excavatfac Mir 9. Ciaa = Pool Coapombon to brrtall smd rWnfnrc mx= per rang n=rcd spWi5crti01s. 14.O dtm Pod Carporstim to apply 9udby watraflcd Smf c sui tm. IL Owner is rvaas lls for wwufi tr pthe fbr savcyt days afta ima>dle d _ 1A Grstw Pool Om"atk m to isi" r band of wataliaa: )300 t t $taadiwd Tide 13. Gi tao pool omVvrWou W bmil mterW spa bcfag is 1 4.0= /MW )fr�Lfiwd�fa(>ddk�r!(a1( 1S. Gattirsa Pool Curprestion to isistaiil i tawr raafW= at )tW14k1�f1*( r 14N41W#(i3C ! 9Yhbe Pleader 16. Cadmo Pact C.atpontfma tv bxts l _ g0ti sgttsre feet of COMM 1 0649900fiYaWAra firvans J 'daiWjrgv!x 17. Go am Pool Corporation to provide WtW d Kt -up of swimming pool for ate week. EQU E MENT AND FMTERING SPECIIrACATIiONS : Pentair IL C,maidge fii W. a20 941t 19. Pump sand motor: _ _ Vaiiable Speed —hp 2L Pool sod spa I ' 259 QOO Wu 2L b bame axmrnf systoro U Automa is skimmer with kaf'atmica baW= 23. Paa) ogidp mut m be fmspdW wdth m 69 The of epa. cs 24. Va= line for tamable PoO vac lm, W iKf ii. 2&Nadscorsa> madc pool vasaiomo. )(1►W / No 16. Anmmatfa traam All device 27. EgWp wm to be iomWed wttlda 80' ft of the ps meter. X (iod= Pod Carporadw to install: sofa systraa /X.,NWXX ELECTRICAL sPEcWxcA,noNS 29. Equfpmeat to bo h%ww vfttu 60 A ortba dm:vw meta. 30. Li& switches to be IasubW aacqwp - 31. Gsatttao Pool Cotporaion to istall am ISM fa to pool. 32. Ostiaro Pool Corporation 10 inms oase Usk is the spat, 33. Oett+sta Pool C*Tcn[tim fo i uW1 am w mbegnoor time ckxL 34. Owaor to WW We= to meet code. X Oww so W* pool bwtiess op to ft code. 3 L Owaerta mp* satiy Ia catvsW by oenanaetim of do pool Jaichadhag 4aodscspiag, "Oft mtd aprsnldtrs. 37. MWw uk to be pmhrrued by (lalheso Pbd Cap4radkM paramt t* egymt shrill be Dmnmmvcd vPKwitnstcly .,__Z _ dw a ftr the dais of city pa mb lamed cad 1W he satastaatfstiy cantpkRed Apprm WtmWy 6 wcdm adtcx iftc wa ik is gaud. C►��y r�:ti9 PAYMEN"X'S Ttiosl eaatraot aaarnrat.: S 319.500.00 Amu=Dow=S 100Q.CQ -W% due upon compmpkOw ofare w dfoa: 3 11.5N.00 35% dw upon corrpk2im of grid W S _ _ 13,475.00 38% due Was eomgtiatioat of tSn $ _ _ 11, 550.00 POOL W2U 1VD AK PLASYMM iJ1VM 7'ZMW PA7AWArl3'AXff SCZffM 3%dueM" WW&6art ofplular. S 1.925.00 Tha BOW (9) aticnvwiedM than bdom ffiv=9 tlsia oarutrard . the bttyrr (s) raaavrai ind seed a l wl*. cmp%Wy good in copy nutria cachet The littM (s) will marine a copy a cM docum t aigaed daring the paaf 009*0600, kckkft daa POO d mwiayt . The bn]"er ($) bw rend fitsat and back of this aaalract red as oUr docuesrmis sad agrees COD -PC housed by an the aunt caudlt = hmein oeasairtcd. llaya(s) bAber adawwledges that hehhe bats m=vcd a Notice or Can ken of s right 0 this 6706? 67 j �2 f�l� 07/1012019 s,nar arc am i 7 Wtve Darts ' LAWYERS TITLE RECORDING REQUESTED BY: LAWYERS TITLE AND WHEN RECORDED MAIL TO: JASON L. GOFF 53025 Avenida Alvarado La Quinta, CA 92253-3433 DOC # 2019-0264179 07/17/2019 08:00 AM Fees: $14.00 Page 1 of 1 Recorded in Official Records County of Riverside Peter Aldana Assessor -County Clerk -Recorder "'This document was electronically submitted to the County of Riverside for recording— Receipted by: MARY #420 a— OfI� THIS SPACE FOR RECORDER'S USE ONLY: Title 6rder Np.: 119081570 Escrow No.: 022535-TF AP#: 774043013-1 GRANT DEED 4: ova- lyf THE UNDERSIGNED GRANTOR(S) DECLARE(S) DOCUMENTARY TRANSFER TAX Is $331.10 [X] computed on full value of property conveyed, or [ J computed on full value less value of liens or encumbrances remaining at time of sale. [ ] Unincorporated area [X] City of La Quinta AND FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, ILONA M. CLEVENGER, CO TRUSTEE OF THE ROBERT H. CLEVENGER LIVING TRUST DATED APRIL 14, 2013 AND ANY AMENDMENTS THERETO hereby GRANT(s) to:JASON LEE GOFF and ANJALI V. NAGARKAR, HUSBAND AND WIFE AS COMMUNITY PROPERTY WITH RIGHT OF SURVIVORSHIP the real property in the City of La Quinta, County of Riverside, State of California, described as: Lot 1, Block 176 of Santa Carmelita at Vale La Quinta Unit No. 18 as shown by map on file in Book 19, Pages 30 and 31 of Maps recorded on in the office of the County Recorder of Riverside County, California. Also Known as: 53025 Avenida Alvarado, La Quinta, CA 92253-3433 ILONA M. CLEVENGER, CO TRUSTEE OF THE Dated June 13, 2019 ROBERT H. CLEVENGER LIVING TRUST DATED APRIL 14, 2013 AND ANY AMENDMENTS THERETO By: LONA M. CLEVENG , C TRUSTEE A notary public or other officer completing this certificate verifies only the identity of the individual who signed the document to which this certificate is attached, and not the truthfulness, accuracy, or validity of that document. STATE OF CALIFORNIA COUNTY OF tail On before me, A Notary Public personally appe red who proved to me on the basis of satisfattory evict nce to be the p on(s) whose name(s) islare subscribed to the within instrument and acknowledged to me that he/she/they executed the same in hislherltheir authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WITNESS my hand and official seal. PHILUP PALAZUELOS Notary Public - California z : Orange County a Signatur (Seal) x Commission # 2154041 NlComm. Ex irac Jun 17. 2020 MAIL T TS T SHOWN BELOW; IF NO PARTY SHOWN, MAIL AS 680.4 Table 680.3 Other Articles Topic Section or Article Site lighting systems operating at 30 volts or less Audio equipment Adjacent to pools and fountains Underwater speakers* 41 1.4(3) Article 640, Parts I and lI 640.10 *Underwater loudspeakers shall be installed in accordance with 680.27(A). 680.4 Approval of Equipment. All electrical equipment installed in the water, walls, or decks of pools, fountains, and similar installations shall comply with the provisions of this article. 680.5 Ground -Fault Circuit Interrupters. Ground -fault circuit interrupters (GFC[s) shall be self-contained units, circuit -breaker or receptacle types, or other listed types, 680.6 Grounding. Electrical equipment shall be grounded in accordance with Parts V, V1, and V11 of Article 250 and connected by wiring methods of Chapter 3, except as modified by this article. "The following equipment shall be grounded: (1) "Through -wall lighting assemblies and underwater luminaires, other than those low -voltage lighting products listed for the application without a grounding conductor (2) All electrical equipment located within 1.5 m (5 11) of the inside wall of the specified body of water (3) All electrical equipment associated with the recirculating system of the specified body of water (4) Junction boxes (5) Transformer and power supply enclosures (6) Ground -fault circuit interrupters (7) Panelboards that are not part of the service equipment and that supply any electrical equipment associated with the specified body of water 680.7 Cord -and -Plug -Connected Equipment. Fixed or stationary equipment, other than underwater luminaires, for a permanently installed pool shall be permitted to be connected with a flexible cord and ping to facilitate the removal or disconnection for maintenance or repair. (.A) Length. For other than storable pools, the flexible cord shall not exceed 900 mm (3 ft) in length. (B) Equipment Grounding. The flexible cord shall have a copper equipment grounding conductor sized in accordance with 250.122 but not smaller than 12 AWG. The cord shall terminate in a grounding -type attachment plug. 7 a-606 (C) Construction. The equipment grounding conductors shall be connected to a fixed metal part of the assembly. The removable part shall be mounted on or bonded to the fixed metal part. owOverhead conductors shall meet the clearance requirements in this section. Where a minimum clearance from the water level is given, the measurement shall be taken from the maximum water level of the specified body of water. With respect to service -drop conductors, overhead service conductors, and open overhead wiring, swimming pool and similar installations shall comply with the minimum clearances given in Table 680.8(A) and illustrated in Figure 680.8(A). Informational Note: Open overhead wiring as used in this article typically refers to conductor(s) not in an enclosed racewav, 13 \ •A B B A / B �l I I A 1 Ohservation stand Fool �— C Communications, radio, and television coaxial cables within the scope of Articles 800 through 820 shall be permitted at a height of not less than 3.0 in (10 ft) above swimming and wading pools, diving structures, and observation stands, towers, or platforms. The minimum clearances for overhead network - powered broadband communications systems conductors from ools or lountains shall comply with the provisions in for conductors operating MAW 680.9 Electric Pool Water Heaters. All electric pool water heaters shall have the heating elements subdivided into loads not exceeding 48 amperes and protected at not over 60 amperes. The ampaciiy of the branch-circuii conductors and the rating or setting of overcurrent protective devices shall not be less than 125 percent of the total nameplate -rated load. 2010 Califomia Electrical Codc - - -. w EST .. _ -. _ __ ��c- ,� � _ _ �•_: _ � - - _ ...: ARTICLE 680 — SWINLMING POOLS, FOUNTAINS, AND SIMILAR INSTALLATIONS 680.20 C A C `A A C A C 1 L III Supported on and Cabled All Other Conductors Voltage to Ground Together with a Solidly — Grounded Bare Messenger or Solidly Grounded Neutral Conductor _ 0 through 15 Kv Over 15 through 50 kV Clearance.Parameters m ft In ft sn ft Clearance in any direction 6.9 22.5 7.5 25 8.0 27 to the water level, edge of water surface, base of diving platform, or permanently anchored raft Clearance in any direction 4.4 14.5 5.2 17 5.5 18 to the observation stand, tower, or latform -diving )loci-rontal liixtit of This limit shall extend to the outer edge of the strictures listed in A and B of clearance measured from this table but dot less than 3 m (10 ft). inside wall of the pool 680.10 Underground Wiring Location. Underground wiring shall not be permitted under the pool or within the area extending 1.5 in (5 ft) horizontally from the inside wait of the Pool unless this wiring is necessary to supply pool equipment permitted by this article. Where space limitations prevent wiring from being routed a distance 1.5 m (5 ft) or more from the pool, such wiring shall be permitted where installed in complete raceway systems of rigid metal conduit, intermediate metal conduit, or a nonmetallic raceway system. All metal conduit shall be corrosion resistant and suitable for the location. The minimum cover depth shall be as given in Table 680.10. 680.11 Equipment Rooms and Pits. Electrical equipment shall not be installed in rooms or pits that do not have drainage that prevents water accumulation during normal operation or filter maintenance. 680.12 Maintenance Disconnecting Means. One or more means to simultaneously disconnect all ungrounded conductors shall be provided for all utilization equipment other than lighting. Each means shall be readily accessible and within sight from its equipment and shall be located at least 1.5 in (5 Il) horizontally Iiom the inside walls of a pool, spa, fountain, or hot tub unless separated from the open water by a permanently installed barrier that provides a 1.5 m (5 ft) reach path or greater. This horizontal distance is to be measured from the water's edge along the shortest path required to reach the disconnect. 680.13 Gas Chlorination Equipment Rooms [DPH] (A)Switch Location. Switches for the control of mechanical ventilation and lighting fixtures in a room used for gas chlorination equipment shall be located adjacent to the entry door outside of the room. Each ,%-witch shall be clearly labeled "Tian On Before Entering. " (B)Equipment Interlocks. The gas chlorine feeding devices shall be interlocked with the pool recirculating pump so that the gas chlorine feeding devices shall not operate when the recirculating pump is qff or during the filter backwash cycle. 2016 Califomia F.leclrieal Code 680.14 Emergency Switch for Spa Pools. [DPHJ A clearly C labeled emergency shuloff switch for the control of both the A recirculation ,system and the aeration and/or jet system shall C be installed adjacent to the spa pool. A Table 680.10 Minimum Cover Depths Minimum Cover Wiring Method mm in. Rigid metal conduit 150 6 Intermediate metal 150 6 conduit Nonmetallic raceways 150 listed for direct burial under minimum of 102 inm (4 in.) thick concrete exterior slab and extending not less than 162 mm (6 in.) beyond the underground installation Nonmetallic raceways 450 18. listed for direct burial without concrete encasement Other approved 450 18 raceways* *Raceways approved for burial only where concrete encased shall require a concrete envelope not less than 50 mm (2 in.) thick, II. Permanently Installed Pools 680.20 General. Electrical installations at permanently installed pools shall comply with the provisions of Part I and Part 11 of this article. 70-607 Equipment Anchored To Slab, 6' Block Wall On Ent 11/4" Poly Pipe - 10a Enna][ i Latching Gate ! :... .. AW • A gArT" L'f �t�-- e M I N i m LAM Cw r+V`2" 1- C1-= -�" UildOuC t6?- Pef- tFop-NtAtrt�t� -tjC' C- OWNER INFORMATION Name: lawn Gulf Address: 53025 Avenedia Alvarado City: La Ouinta State: CA Sip: 92234 Primary #: 1-260-534-1183 secondary #: CONTRACTOR INFORMATION Name: Gattuso Pools Address: 667 Eugene Road CRy: Palm Sprigs State: CA Zip: 922" Primary#: 1-760-327-1592 Secondary#: Pool Specifications Size: 26z 6' Sq.Fn 136 So. Ft. Depth: 313" x 6' Perimeter: 62 Linear Feet FEE .6: Fee +12: RBB+18: RED+24: RED +36: RED OMec Nopm: special: Spa Specifications Sue: 6' x 6' sq.Ft 36 so_ Ft Depth: 42' Perimeter: 24 Linear Feet RB8+6: RED+12: RBB+18: Yea RBB+24: RED+36: RED Other: Notes: Special: Pool Plumbing Skimmer 1: 2112" Skimmer 2: Skimmer 3: Main Brain: 2" Equagzer Pool Vac Return 1: Return 2: Return 3: WF 15uc W F 2 Ran WF 1 Bypass; WF 2 Sec WF 2 Ret: W F 2 Bypass: Gas Main: 1114" Gas Branches: Gas Foatagn 100' Main BTU: 250,000 Branch BTU: Total BTU: 250,000 Notes: Special: Spa Plumbing Skimmer 1: skimmer 2: Main Drain: 2112" Equalrsec lets: 6 Bottom Return I Valve: Sooner i 5uc Booster 1 get: leis: Booster 2 Sac: Booster 2 get: lets: WF 1 Suc: WF 1 get: WF: Notes: Special: Coping / Decking Coping 1: Concrete selection: Cantu ever Footage: 1100' nnish: Broom Coping 2 Selection: Footage: Finish: Deck 1: Concrete Selectom NA Footage: NA Fni h: Broom Deck 2: Sahmppm Footage: Finish: Notes: Special: Pool Material Waterline: Tile Selecton: TBD Footage: 62' Accents: Selection: Footage: RBB: Selection: Feelings: FEE Face: Selecumm Footage: Interior Plaster Selection: White Footage: 62' Notes: Special: Spa Material wamdlne: TUe Accents: RBB: ROD Panic Interior: Plaster Notes: special: Equipment: Manufacturer l: landu Pump 1: Variable FINer 1: 325 So. Ft hangar 1: 250,000 BTU Pas Light 1: 406W Pool Light 2: Spa Light SOW Controller: EasvTouch Selection: TBD Selection: Selectum selection: Selection: White Pump 2: Filter 2: H-ter 2: LED: LED: LED: Wall Moum: No Inpacram Yes Footage: 24' Footage: Footage: Footage: Footage: 24' Pump 3: Media: Wrtridae vent: 1 Style: standard C 9 Enter Style: Standard • He" Held: Site Yes M1 Notes: SPeckl: Scale: 1/8" = 1