BRER2019-016478-495 CALLE TAMPICO C 0 D 4 10"PlAl VOICE (760) 777-7125
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011
DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Permit Type/Subtype: RE -ROOF/ Owner:
Application Number: BRER2019-0164 BARBARA THOLE TESTA
Property Address: 54505 AVENIDA DIAZ 54505 AVENIDA DIAZ
APN: 774263013 LA QUINTA, CA 92253
Application Description: THOLE / 2500SF REROOF
Property Zoning:
Application Valuation: $10,000.00
Applicant. P
Contractor:
VISION ROOF SERVICES INC VISION ROOF SERVICES INC
41905 BOARDWALK SUITE L AUG 2 2 2019 41905 BOARDWALK SUITE L
PALM DESERT, CA 92211 PALM DESERT, CA 92211
CITY OF ;A QUINTA (844)348-7663
DESIGN & DMOPMENi DEPARTMENT LIc. No.: 651509
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9
{commencing with Section 7000) of Division 3 of the Business and Professions Code, and
my License is in full force and effect.
License CCii�ass License No.-, 651509
Date: L+ Z Contractor-
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any
structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the
alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that he
or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to
construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State
License Law does not apply to an owner of property who builds or improves thereon,
and who contracts for the projects with a contractor(s) licensed pursuant to the
Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Addre!
Date: 8/21/2019
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the ark for which this permit is issued.
l—" I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My workers' compensation insurance carrier and policy number are:
Carrier: AMERICAN ZURICH &SUBARCE COMPANY Policy Number:
_ I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with t pse pro`isions.
Date: Z r Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit issued
as a result of this application , the owner, and the applicant, each agrees to, and shall
defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not
commenced within 180 days from date of issuance of such permit, or cessation of work
for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the above -
mentioned property for
Inspection purposes. (/1
Date: II Signature (Applicant or Agent): l�'�
Date: 8/'21/2019
Application Number:
BRER2019-0164
Property Address:
54505 AVENIDA DIAZ
APN:
774263013
Application Description:
THOLE / 25005F REROOF
Property Zoning:
Application Valuation:
$10,000.00
Applicant:
VISION ROOF SERVICES INC
41905 BOARDWALK SUITE L
PALM DESERT, CA 92211
Detail: REROOF WITH FOAM AT GARAGE [CRRC: 0684-0003] 2016 CALIFORNIA ENERGY CODE.
Owner:
BARBARA THOLE TESTA
54505 AVENIDA DIAZ
LA QUINTA, CA 92253
Contractor:
VISION ROOF SERVICES INC
41905 BOARDWALK SUITE L
PALM DESERT, CA 92211
(844)348-7663
Llc. No.: 651509
1 n-:J sue_ n1111 nlw P-In•wn- w A. w
1 U&OI ra IU IUI ummunwha J IMiv Lpr%nL/7 MYIY111YIJ 1nM1 nim Dim. 171.UU
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RE -ROOF - EA ADDITIONAL 1,000 SF
101-0000-42404
0
$12.81
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RE -ROOF - FIRST 2,000 SF
101-0000-42404
0
$54.43
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RE -ROOF - FIRST 2,000 SF PC
101-0000-42600
0
$108.87
Total Paid for RE -ROOF: $176.11
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
TOTALS: $182.11
STATE OF CALIFORNIA
Prescriptive Residential Alterations That Do Not Require HERS Field Verification
111
CEC-CF1R-ALT-05-E (Revised 07/17) CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE CF1R-ALT-05-E
Prescriptive Residential Alterations That Do Not Require HERS Field Verification Page 1 of 3
Project Name: Date Prepared:
This compliance document is only applicable to
with a HERS Provider Data Registry.
not require HERS verification for compliance. When HERS verification is required, a CFIR-ALT- 01 shall first be registered
Alterations to Space Conditioning Systems that are exempt from HERS verification requirements may use the CF1R-ALT-05 and CF2R-ALT-05 Compliance Documents. Possible exemptions from duct
leakage testing include: less than 40 ft of ducts were added or replaced, or the existing duct system was insulated with asbestos, or the existing duct system was previously tested and passed by a
HERS Rater. If space conditioning systems are altered and are not exempt from HERS verification, then a CF1R-ALT-02 must be completed and registered with a HERS Provider Data Registry.
Alterations that utilize close Cell Spray Polyurethane Foam (ccSPF) with a density of 1.5 to less than 2.5 pounds per cubic foot having an R-value other than 5.8 per inch, or Open Cell Spray
Polyurethane Foam (ocSPF) with a density of 0.4 to less than 1.5 pounds per cubic foot having on R-value of 3.6 per inch, shall complete and register a CF1R-ALT-01 with a HERS Provider Data
Registry.
If more than one person has responsibility for installation of the items on this certificate, each person shall prepare and sign a certificate applicable to the portion of construction for which they are
responsible. Alternatively, the person with chief responsibility for construction shall prepare and sign this certificate for the entire construction. All applicable Mandatory Measures shall be met.
Temporary labels shall not be removed before verification by the building inspector.
A. General Information
01
Project Name:
02
Date Prepared.
/
03
Project Location:
L1(5-0
04
Building Front Orientation (deg or cardinal):
05
CA City:
L Q
06
Number of Altered Dwelling Units:
07
Zip Code:
L Z 3
08
Fuel Type:
09
Climate Zone:
�-
10
12
Total Conditioned Floor Area (ft):
Slab Area (ft)
11
Building Type:
✓
13
Project Scope (Select all that apply):
❑ B. Insulation ❑ D. & E. Fenestration/Glazing - ADD ❑ G. Space Conditioning System (Heating, Cooling, Duct system) ❑ Lighting
❑✓ C. Roof Replacement ❑ D. & F. Fenestration/Glazing - REPLACE ❑ H. Water Heating System ❑ Include Mandatory Measures?
CA Building Energy Efficiency Standards - 2016 Residential Compliance
July 2017
STATE OF CALIFORNIA
Prescriptive Residential Alterations
CEC-CF1 R-ALT-05-E (Rewsed 07/17)
CERTIFICATE OF COMPLIANCE
That Do Not Require HERS Field Verification
Prescriptive Residential Alterations That Do Not Require HERS Field Veritication
Project Name:
Date Prepared
NIA
CF1R-ALT-05-E
Page 2 of 3
C. Roof Replacement (Prescriptive Alteration, Section 150.2(b)1H)
01
02
03
04
05
06
07
08
09
10
11
12
13
Proposed
Minimum Required
Method of
Compliance
1 Roof Pitch
I Exception
CRRC Product
ID Number
Product
Type
R-value
Deck
Insulation
Initial Solar
Reflectance
Aged Solar
Reflectance
Thermal
Emittance
SRI
(Optional)
Aged Solar
I Reflectance
Thermal
Emittance
SRI
(Optional)
!
u
Add Row
Delete Row
NOTES:
• Roof area covered by building integrated photovoltaic panels and solar thermal panels are exempt from the above Cool Roof requirements.
• Liquid field applied coatings must comply with installation criteria from Section 110.8(i)4.
July 2017
CA Building Energy Efficiency Standards - 2016 Residential Compliance
STATE OF CALIFORNIA
Prescriptive Residential Alterations
CEC-CF1 R-ALT-05-E (Revised 07/17)
CERTIFICATE OF COMPLIANCE
That Do Not Require HERS Field Verification
CALIFORNIA ENERGY
CF1R-ALT-05-E
Prescriptive Residential Alterations That Do Not Require HERS Field Verification Page 3 of 3 1
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
DocumentatianAu[hor Name: %-]� �
,
Documentation Author Signature:
Company: / 7� /
�t�T s
Signature Date:
U 7
Vi C o vi c� i rt—J
Address: _
G-
CEA/ HERS Certification Identification (if applicable):
Liry/Sta[e1Zip: Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible
designer).
3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of
Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
5. 1 will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency
for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building
owner at occupancy.
Responsible Designer Name: - Responsible Designer Signature:
Company: Date Signed: G
Address:
License: /
City/State/zip:
aA ��3 �2-
Phone:
70
For assistance or questions regarding the Energy Standards, contact the Energy Hotline at: 1-800-772-3300.
CA Building Energy Efficiency Standards - 2016 Residential Compliance
July 2017
Q�dwra
C..0 11PO MA
Project Address:
PERMIT # 0A(
PLAN LOCATION:
Project Description:
APN #:
�. -
Applicant Name:
Address:
City, ST, Zip:
Telephone: JC2 7 L'
Email: C�v�SQ �'b� Vvns.�,
Project Valuation $ �
Contractor Name:
',��. ; _ f2Q `
sNew SFD Construction:
Address: L 5-
ryL, �`:�u, '�r L
Conditioned Space SF
City, St, Zip.�`,�
tc.��,, << 1
Garage _SF
Telephone: ��
�/ i }
Patio/Porch SF
Email:
Fire Sprinklers _ SF
State Lic: l 5C;
City Bus Lic:
Architect/Engineer Name:
Construction Occupancy:
Address:
Grading:
City, St, Zip
Telephone:
Bedrooms:
Stories:
# Units:
Email:
State Lic: City Bus Lic:
Property Owner's Name:w�1va K ( v(�2
New Commercial / Tenant Improvements:
Address: ;�c� 5'v� ,� �
Total Building SF
City, ST, Zipa 0 ,,G�k 6,0 y2,2- 3
Construction Type: Occupancy:
Telephone: (Z,r 3) ZY/ -- 21 e3
Email:
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
OFFICE USE ONLY
# Submittal
Required
Received
Plan Sets
Structural Calcs
Truss Calcs
Title 24 Calcs
CVWD Fire Flow Letter
Soils Report
Grading Plan (PM10)
Landscape Plan
Subcontractor List
Grant Deed
HOA Approval
School Fees
Burrtec Debris Plan
Planning approval
Public Works approval
Fire approval
City Business License
(our Pr6posal
r
7/23/19, 2:00 PM
VISION
ROOF SERVICES
Vision Roof Services (Lic 651509)
Corporate Office: 41905 Boardwalk Suite L. • Palm Desert, CA 92211
Phone- 844-348-7663
Barbara Thole
213 241 9183
54505 Avenida Diaz
La Quinta, CA 92253
Print -date: 7-23-2019
Vision Roof Services, Inc will furnish all material and labor to complete this construction agreement
NEW FOAM ROOF_ANP COATING SYSTEM WITH GRA�iULES
• Pull a city re -roof permit.
■ Remove all gravel over garage and haul away.
• Included in price removal and replacement of 5 sheets of plywood, Anymore sheets needed will be changed out at a
charge of $60.00 per sheet installed
• Prepare existing roof system for foam roof and coating system.
• Remove all physical damage to existing roof, drain problem areas and re -foam with new foam-
• Power broom existing roof to prepare for new foam roof and new coating system-
• Mask and tape to protect from over spray.
■ Spray apply 1 inch of foam over existing roof system (insulation value of R-7).
■ Spray apply 3 gallons per 100 Sq. Ft of TITLE 24 Pro -tech EC120 white elastomeric top coating. (white elastomeric
coating is a reflective energy efficient coating that protects foam roof from long term from UV degradation,
• Included in price: Add 3' foam/elastomeric extension at end of the breezeway extending onto the house roof above
the patio in order to repair leaking problem area
■ Imbed white acrylic granules into the wet top coating finish. (creates a protective surface and bird stop).
• Apply silicone to a 3' x 3' area on all 4 corners of main house
.■ Clean up job site and haul away all trash and debris.
• Issue a 10 year NO LEAK Warranty
o Wallao(y excludes Inie(ior Draios, 10echar ica/ Onifs and Skyhr/his
-eJoe wkt� YleeA
('.;A RAGE ROOF TOTAL INVESTMENT: $11,984.00
PAYMENT TERMS:
• 10% Deposit Down
• Final Amount Due Upon Roof Completion
https://buildertrend.net/Leads/Lead ProposalExternal.aspx?leadlD=dglvd2M62CM&proposalld=_IR8nTUXMls&openPrint=True Page 1 of 3
r Flour Prdposal
7/23/19, 2:00 PM
• Check/ACH Transfer
• Credit Card
CUSTOMER PORTAL via Buildertrend (mobile app or website)
• View your job proposal(s)
• Make on -like payments
• View photo's (before, in -progress and final)
• View invoices, payments
• Manage change orders
• Messaging
Inquire for invitation to your view your account or for more information.
Attached Files:
ACKNOWLP.�:DGL;elENT: Owner acknowledges that he/she has read and received a legible copy of this agreement including
all terms standard provisions, applicable attached job descriptions, and notice to Owner on reverse side
ACCEPTANCE: [iie above prices, specifications and conditions are satisfactory and hereby accepted. You are authorized
to cornp,c c; ,'h, as 6p,,fled. Payment will be per the conditions outlined above
TO RESCIND: Buyer has the right to rescind this agreement within 3 days. Cancellation must be made in writing
Additional Work - Ir BLlyer/Homeowner requests any alteration to specifications, there will be an extra charge for agreed
upon additional v,;:r.
VRS shall assume no responsibility for the operation of, or damage to existing solar panels, gutters, skylights, air condition-
ers, etc due to deteriorated conditions of these objects
VRS Is not responsible for correcting existing roof surfaces to eliminate ponding or collection of water unless included in the
terms of this agreement.
Should leua' proc:;eaings by VRS become necessary for collecting monies due for materials and/or services provided by
VRS, 131-1yer/1-lomno�vner agrees to pay all actual costs of collection: including reasonable attorney costs and fees.
Should 131_1yel/1-lomeowner tail to pay this invoice when due, buyer/ homeowner agrees to pay monthly service charges of
1 5% per month (1 8�7', per annum) of outstanding balance due.
VRS is not resprmsil,-Je for darnage to driveways due to pre-existing conditions
This agreement is based orl completed lob only. Additional materials remain the property VRS
VRS reserves the 1 Ight to rescind this agreement any time prior to start date
NOTICE TO BUYER
Under the California Mechanics Lien Laws any contractor, subcontractor, laborer, supplier, or other person who helps to im-
prove property, but is not paid for his/her work or supplies, has a right to enforce a claim against your property- This means
that after a court hearing, your property could he sold
https://buildertrend.net/Leads/Lead ProposalExternal,aspx?leadlD=dglvd2M62CM&proposalld=_IR8nTUXMls&openPrint=True Page 2 of 3
',ouc Pr3posaI
7/23/19, 2:00 PM
By a court officer and the proceeds of the sale used to satisfy the indebtedness This can happen even if you have paid your
contractor in full If the subcontractors; laborers, or suppliers remain unpaid
To preserve their rights to file a claim or lien against your property, certain claimants such as subcontractors or material sup-
pliers are required to provide a document entitled ''Preliminary Notice." Original (or prime) contractors and laborers for
wages do not have to provide this notice. A Preliminary Notice is not a lien against your property. Its purpose is to notify you
of persons who may have a right to file a lien against your property if they are not paid. (Generally, the maximum time -al-
lowed for filing a claim or lien against your property is ninety [90) days after completion of your project).
Require that payment be made directly to subcontractors and material suppliers through a joint control. Any joint control
agreement should include the addendum approved by the Registrar of Contractors. Issue joint checks for payment made out
to both contractor and subcontractor or material suppliers involved in the project. This will help to ensure that all persons
due payment are actually paid.
After making payment on any completed phase of the project, and before making further payments, require your contractor
to provide you with unconditional lien releases signed by each material supplier, subcontractor and laborer involved in that
portion of the work for which the payment was made. On projects involving improvements to a single family residence or du-
plex owned by individuals, the persons signing these releases lose this right to file a claim against the property. In all other
types of construct on this protection may still be important, but may not be as complete. To protect yourself under the option
you must be certain that all material suppliers, subcontractors or laborers have signed.
Contractors are required by law to be licensed and regulated by the contractors States Board. Any questions concerning a
contractor may be referred to the Register of Board whose address is: Contractors State License Board 9835 Goethe Road,
Sacramento. CA 95327. Mailing address: PO Box 26000, Sa amento, CA 95826
Signature
Print Name:
Date:
`Only one proposal can be approved. Approving this will decline all other available proposals.
https://buildertrend.net/Leads/Lead ProposalExternal_aspx?leadlD=dglvd2M62CM&proposalld=_IR8nTUXMls&open Print=True Page 3 of 3