BRES2019-020278-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Permit Type/Subtype:
Application Number:
Property Address:
APN:
Application Description:
Property Zoning:
Application Valuation:
Applicant:
ELMER GARCIA
67375 MEDANO ROAD
CATHEDRAL CITY, CA 92234
Tjhr44uQu&rw
DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT
BUILDING RESIDENTIAL/REMODEL
BRES2019-0202
78010 CORONADOS CIR CIR
646210001
COLBURN / REMODEL + CONVERT 96SF LIVING SPACE TO PATIO
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Owner:
DAVID COLBURN
78010 CORONADOS CIRCLE
LA QUINTA, CA 92253
Date: 8/22/2019
$1.00
Contractor:
AUG `' t �f1�9D MODERN TOUCH CONSTRUCTION
U 67685 BROKEN ARROW LANE
F D DESERT HOT SPRINGS, CA 92234
CITY OF ;AQUiNTA
DESIGN &DEVELOPMENT DEPARTMENT (760)835-2777
Llc. No.: 1004355
LICENSED CONTRACTOR'S DECLARATION
hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9
(commencing with Section 7000) of Division 3 of the Business and Professions Code, and
my License is in full force and effect.
License Class: B License No.: 1004355
Date: d 247 Contractoc.�0_1/jri�,
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any
structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the
alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that he
or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to
construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State
License Law does not apply to an owner of property who builds or improves thereon,
and who contracts for the projects with a contractor(s) licensed pursuant to the
Contractors' State License Law.).
(_) I am exempt under Sec. B.&P.C. for this reason
Date: Owner;
CONSTRUCTION LENDING AGENCY
hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Na
Lender's
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of th rk for which this permit is issued.
. I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My workers' compensation insurance carrier and policy number are:
Carrier: NORGUARD INSURANCE COMPANY Policy Number: MOWC031852
_ I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date:S Appllca'4T' a
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit issued
as a result of this application , the owner, and the applicant, each agrees to, and shall
defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not
commenced within 180 days from date of issuance of such permit, or cessation of work
for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the above -
mentioned property for inspection purposes.
Date: �Z Signature (Applicant orAgenk. e I I Z_
Date: 8/22/2019
Application Number: BRES2019-0202
Property Address: 78010 CORONADOS CIR CIR
APN: 646210001
Application Description: COLBURN / REMODEL + CONVERT 965F LIVING SPACE TO PATIO
Property Zoning:
Application Valuation: $1.00
Applicant:
ELMER GARCIA
67375 MEDANO ROAD
CATHEDRAL CITY, CA 92234
Owner:
DAVID COLBURN
78010 CORONADOS CIRCLE
LA QUINTA, CA 92253
Contractor:
MODERN TOUCH CONSTRUCTION
67685 BROKEN ARROW LANE
DESERT HOT SPRINGS, CA 92234
(760)835-2777
Llc. No.: 1004355
Detail: COLBURN / REMODEL - CONVERT 965F OF LIVING SPACE TO EXTERIOR PATIO AREA, REPLACE ALL WINDOWS AND DOORS, NEW PLUMBING
FIXTURES THROUGHOUT, NEW LIGHTING AT BATHS AND KITCHEN. THIS APPROVAL DOES NOT INCLUDE THE REPLACEMENT OF HVAC EQUIPMENT,
WATER HEATER, OR ELECTRICAL SERVICE PANEL. 2016 CALIFORNIA BUILDING CODES.
DESCRIPTION ACCOUNT CITY AMOUNT
HOURLY CHARGE - ESGIL CIVIL ENGINEER 101-0000-42600 2 $210.00
Total Paid for BLDG CITY STAFF - PER HOUR: $210.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
BSAS SB1473 FEE
101-0000-20306
0
$1.00
I Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DEVICES, FIRST 20
101-0000-42403
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES, FIRST 20 PC
101-0000-42600
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES/FIXTURES, ADDITIONAL
101-0000-42403
0
$120.15
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES/FIXTURES, ADDITIONAL PC
101-0000-42600
0
$30.15
Total Paid for ELECTRICAL: $203.66
DESCRIPTION
ACCOUNT
CITY
AMOUNT
EXHAUST HOOD
101-0000-42402
0
$13.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
EXHAUST HOOD PC
101-0000-42600
0
$5.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
VENT FAN
101-0000-42402
0
$40.02
DESCRIPTION
ACCOUNT
CITY
AMOUNT
VENT FAN PC
101-0000-42600
0
$16.02
Total Paid for MECHANICAL: $74.72
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PLAN CHECK DEPOSIT - ADDITION/REMODEL
101-0000-42600
1
$125.00
Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $125.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FIXTURE/TRAP
101-0000-42401
0
$146.74
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FIXTURE/TRAP PC
101-0000-42600
0
$146.74
DESCRIPTION
ACCOUNT
CITY
AMOUNT
GAS SYSTEM, 1-4 OUTLETS
101-0000-42401
0
$13.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
GAS SYSTEM, 1-4 OUTLETS PC
101-0000-42600
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WATER SYSTEM INST/ALT/REP
101-0000-42401
0
$13.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT l
WATER SYSTEM INST/ALT/REP PC
101-0000-42600
0
$13.34
Total Paid for PLUMBING FEES: $360.18
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RECORDS MANAGEMENT FEE
101-0000-42416
0
$10.00
Total Paid for RECORDS MANAGEMENT FEE: $10.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($125.00)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
REMODEL, EA ADDITIONAL 500 SF
101-0000-42400
0
$120.05
DESCRIPTION
ACCOUNT
CITY
AMOUNT
REMODEL, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$96.05
DESCRIPTION
ACCOUNT
CITY
AMOUNT
REMODEL, FIRST 100 SF
101-0000-42400
0
$54.43
DESCRIPTION
ACCOUNT
CITY
AMOUNT
REMODEL, FIRST 500 SF PC
101-0000-42600
0
$23.89
DESCRIPTION
ACCOUNT
CITY
AMOUNT
REMODEL, FIRST 500 SF PC
101-0000-42600
1 0
$125.00
Total Paid for REMODEL: $294.42
DESCRIPTION
ACCOUNT CITY
AMOUNT
SMI - RESIDENTIAL
101-0000-20308 0
$0.50
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $0.50
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
4:
Architect/Engineer Name:
Address:
City, St, Zip
Telephone:
Email
State Lic: City Bus Lic:
Construction
Grading:
Bedrooms: 1 Stories:
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
Occupancy:
# Units:
OFFICE NSE ONLY
# Submittal Required Received
Plan Sets
I Structural Calcs
Truss Calcs
1 Title 24 Calcs
Y' Soils Report
Grading Plan (PM10)
Landscape Plan
Subcontractor List
Grant Deed
HOA Approval
School Fees
Burrtec Debris Plan
Planning approval
Public Works approval
Fire approval
i
City Business License
— GEM of the DESERT
78495 CALLE TAMPICO BUILDING DIVISION
LA QUINTA, CALIFORNIA 92253 (760) 777-7125
W W W.LAQUINTACA.GOV FAX (760) 777-701 1
TRANSMITTAL
TO: ❑INTERWEST QllSGIL ❑HR GREEN
❑OTHER
❑COMPLETE PLAN CHECK I•RUGTURAL ONLY 1
TODAY'S DATE: G �. � DUE DATE: ? 3 201 q
PERMIT NUMBER:
PROJECT ADDRESS: CIDIONA00S G
APPLICANT NAME: 96L.MEtL q,gAA M
SUBMITTAL ROUND:_ BIN NUMBER: n L90 Fjftt4T Coy NTF,iYi�
INCLUDED HEREWITH:
PLANS
❑REDLINED PLANS
C� RUCT
❑REDLINED STRUCT
❑TRUSS
❑REDLINED TRUSS
❑SOILS
❑REDLINED SOILS
❑ENERGY
❑REVISED ENERGY
❑CORRECTION LIST
❑REVISED PLANS
❑REVISED STRUCT
❑REVISED TRUSS
❑REVISED SOILS
❑CUSTOMER RESPONSES
R' OTES _ SFIt ! IY' - 1.1 Ml�k � L 7 -• �� g
❑APPROVED PLANS
❑APPROVED STRUCT
❑APPROVED TRUS
[]APPROVED SOILS
LA QUINTA BRES2019-0202
7/8/2019
[DO NOT PAY— THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: LA QUINTA PLAN CHECK #.: BRES2019-0202
PREPARED BY: Bert Domingo DATE: 7/8/2019
BUILDING ADDRESS: 78010 CORONADOS CIRCLE
BUILDING OCCUPANCY: R 3
BUILDING
PORTION
AREA
( Sq. Ft.)
Valuation
Multiplier
Reg.
Mod.
VALUE ($)
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code LQ Manual Input
1997 UBC Building Permit Fee
1997 IJRC Plan Cherk Fee 1
Type of Review:
❑ Repetitive Fee
Repeats
" Based on hourly rate
L : Complete Review
�,❑ Otthppe������r��
L_±!_
EsGill Fee
❑ Structural Only
2 Hrs. @
$105.00 $2 00
Comments: In addition to the above fee, an additional fee of $ is due ( hour @
$ /hr.) for the CalGreen review.
Sheet 1 of 1
EsGil
A SAF` buM Company
DATE: 7/8/2019 ❑ APPLICANT
❑ JURIS.
JURISDICTION: LA QUINTA
PLAN CHECK #.: BRES2019-0202 SET: I
PROJECT ADDRESS: 78010 CORONADOS CIRCLE
PROJECT NAME: SFD REMODEL FOR COLBURN (STRUCTURAL ONLY)
❑ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
❑ The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
® The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
❑ The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
® The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
❑ The applicant's copy of the check list has been sent to:
® EsGil staff did not advise the applicant that the plan check has been completed.
❑ EsGil staff did advise the applicant that the plan check has been completed.
Person contacted. l f Telephone #:
Date contacted: 1`�� (by'.- ] Email:
Mail Telephone Fax In Person
❑ REMARKS:
By: Bert Domingo Enclosures:
EsGil
6/27/2019
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
LA QUINTA BRES2019-0202
7/8/2019
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK #.: BRES2019-0202 JURISDICTION: LA QUINTA
PROJECT ADDRESS: 78010 CORONADOS CIRCLE
FLOOR AREA:
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION:
DATE INITIAL PLAN REVIEW
COMPLETED: 7/8/2019
FOREWORD (PLEASE READ):
STORIES:
HEIGHT:
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 6/27/2019
PLAN REVIEWER: Bert Domingo
This plan review is limited to the technical requirements contained in the California version of
the International Residential Code, International Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the disabled. This plan review is based on
regulations enforced by the Building Department. You may have other corrections based on
laws and ordinance by the Planning Department, Engineering Department, Fire Department or
other departments. Clearance from those departments may be required prior to the issuance of
a building permit.
Present California law mandates that construction comply with the 2016 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC,
2015 UPC, 2015 UMC and 2014 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2015 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list or a co where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
LA QUINTA BRES2019-0202
7/8/2019
ADO NOT PAY— THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: LA QUINTA PLAN CHECK #.: BRES2019-0202
PREPARED BY: Bert Domingo DATE: 7/8/2019
BUILDING ADDRESS: 78010 CORONADOS CIRCLE
BUILDING OCCUPANCY: R 3
BUILDING
PORTION
AREA
(Sq. Ft.)
Valuation
Multiplier
Reg.
Mod.
VALUE ($)
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
JLQ
Manual Input
1997 UBC Building Permit Fee
1997 UBC Plan Check Fee
Type of Review: ❑ Complete Review Structural Only
❑ Repetitive Fee ❑ Other
Repeats Hourly 2 Hrs. @ "
EsGil Fee $105.00
" Based on hourly rate
Comments: In addition to the above fee, an additional fee of $
$ /hr.) for the CalGreen review.
is due ( hour @
Sheet 1 of 1
LA QUINTA BRES2019-0202
7/8/2019
PLANS
Please make all corrections and submit two new complete sets of prints, to:
The jurisdiction's building department.
2. All sheets of plans must be signed by the person responsible for their
preparation. (California Business and Professions Code).
3. Plans deviating from conventional wood frame construction shall have the
structural portions signed and sealed by the California state licensed
engineer or architect responsible for their preparation, along with
structural calculations. (California Business and Professions Code).
4. Provide a statement on the Title Sheet of the plans stating that this project shall
comply with the 2016 California Residential Code, which adopts the 2015 IRC,
2015 UMC, 2015 UPC and the 2014 NEC. Section R106.1.
MISCELLANEOUS
5. Please show the specifications of the recommended structural elements of the
remodel.
6. It seems that the roofing materials is tile roof. Please show the weight of such
roofing materials.
7. Please have the structural engineer stamp and signed the structural framing
system to include the foundation.
LA QUINTA BRES2O19-0202
7/8/2019
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes ❑ No ❑
The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to
perform the plan review for your project. If you have any questions regarding
these plan review items, please contact Bert Domingo at EsGil. Thank you.
GEM of the DESERT
78495 CALL'E TAMPICO BUILDING DIVISION
LA QUINTA, CALIFORNIA 92253 (760) 777-7125
WWW.LAQUINTACA.GOV FAX (760) 777-7011
TRANSMITTAL
TO: ❑INTERWEST A:SGIL ❑HR GREEN
❑OTHER
❑COMPLETE PLAN CHECK jWSTRUCTURAL ONLY
ATTN
TODAY'S DATE: it/ 4f DUE DATE:��
PERMIT NUMBER: j ; �• ID;• D
PROJECT ADDRESS: 140 —9 �A � r
APPLICANT NAME: --6tA"&-4A C-
SUBMITTAL ROUND: 2ad— __ BIN NUMBER:
INCLUDED HEREWITH:
❑PLANS
ENREDLINED PLANS
❑STRUCT
JUREDLINED STRUCT
❑TRUSS
❑REDLINED TRUSS
❑SOILS
❑REDLINED SOILS
❑ENERGY
❑REVISED ENERGY
CORRECTION LIST
VOTES
[4iEVISED PLANS
[NREVISED STRUCT
❑REVISED TRUSS
❑REVISED SOILS
(NC;USTOMER RESPONSES
[-]APPROVED PLANS
[]APPROVED STRUCT
[]APPROVED TRUSS
❑APPROVED SOILS
■
DATE: 8/19/2019
JURISDICTION: LA QUINTA
v
EsGil
❑ APPLICANT
❑ JURIS.
PLAN CHECK #.: BRES2019-0202 SET: II
PROJECT ADDRESS: 78010 CORONADOS CIRCLE
PROJECT NAME: SFD REMODEL FOR COLBURN (STRUCTURAL ONLY)
® The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's BUILDING codes.
❑ The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
❑ The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
❑ The applicant's copy of the check list has been sent to:
® EsGil staff did not advise the applicant that the plan check has been completed.
❑ EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: / 4 Telephone #:
Date contacted: (by. ) Email:
Mail Telephone Fax In Person
❑ REMARKS:
By: Bert Domingo Enclosures:
EsGil
8/12/2019
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858).560-1576
June 12, 2019
City of La Quinta
Design and Development Department
Building Division
78-495 Calle Tampico
La Quinta, CA 92253
Re: Trades Pulling Permits
Location: 78010 Coronados Circle, La Quinta, CA
92253
APN# 64621001
Greetings La Quinta Building Division,
Per your request I am submitting names of contractors
working at my residence (78010 Coronados Circle, La
Quinta, CA 92253) who already have/or who are in the
process of submitting their applications for permits.
I am also noting the work that they are doing.
Torres Electric #994066
Upgrades to Electrical Sub Panel, Replace existing interior
lighting with LED Fixtures. Replace courtyard lighting
with LED Fixtures.
duality Mechanical Plumbina #923620
Run new water lines and gas lines to appliances, Replace
Kitchen and Bathroom Sinks and faucets, replace Master
Shower Valves and replace (3) Toilets.
LU
N
Artisan Touch_Carrzentry # 1009749
Replace Original Sliding Doors and Picture Windows with
� a,
L U '—
more energy efficient sliding doors/windows. Relocate
and reinstall existing front door. Replace kitchen and
�
bathroom cabinets.
If you have further questions please direct them to my local
Project Manager/Designer: Nicholas Hertneck at 310 854
4
2805.
Than ,
David Colburn, Homeowner
600 North Fairbanks, #2402
Chicago, IL 60611
Y01A ►nc�Y a (so ca f f me 4b Ve►'i '� � 8 4-7 - 01-gOqq
'Th a nle YOU
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
COLBURN RESIDENCE
78010 CORONADOS CIR
LA QUINTA, CA 92253
Project Designer:
GLS ARCHITECTURE GROUP INC.
74991 JONI DR #9
PALM DESERT, CA 92260
760 340.3528
CATY" OF LA QURA A
EUILDING DIVISION
Report Prepared by: REVIEWED FOR
Y CODE
Armando Chavez + C MPLIANCE
OATS ; �!'� BY
44890 SEELEY
LA QUINTA, CA 92253
760 278.1840
RECEIVED
AUG 0 9 2019
CITY OF LA QUINTA
DESIGN AND DEVELOPMENT DEPARTMENT
Job Number:
19-GLS-066
Date:
8/6/2019
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards.
This program developed by EnergySoft Software — www.energysoft.com.
I TABLE OF CONTENTS I
Cover Page
Table of Contents
Form CF-1 R-PRF-01-E Certificate of Compliance
Form RMS-1 Residential Measures Summary
Form MF-1 R Mandatory Measures Summary
1
2
3
10
11
7.1 by EnergySoft JobNumber. ID: 19 - GLS - 066 User Number: 20648
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1 R-PRF-01
Project Name: COLBURN RESIDENCE
Calculation Description: Title 24 Analysis
Calculation Date/Time: 13:07, Tue, Aug 06, 2019
Input File Name: 066 - 78101 CORONADOS CIR.ribd16x
Page 1 of 7
GENERAL INFORMATION
01
Project Name
COLBURN RESIDENCE
02
Calculation Description
Title 24 Analysis
03
Project Location
78010 CORONADOS CIR
04
City
LA QUINTA
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.3.1 (1149)
08
Climate Zone
CZ15
09
Software Version
CBECC-Res 2016.3.1 (1019)
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
180
12
Project Scope
Addition and/or Alteration
13
Number of Dwelling Units
1
14
16
Total Cond. Floor Area (ftZ)
Slab Area (ftZ)
2334
2334
15
17
Number of Zones
Number of Stories
1
1
18
Addition Cond. Floor Area (ftZ)
0
19
Natural Gas Available
No
E20
Addition Slab Area (ftZ)
1 0
21
Glazing Percentage (%)
22.0%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building DOES NOT require HERS Verification
03 This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ftZ-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
21.09
23.61
-2.52
-11.9%
Space Cooling
343.13
302.00
41.13
12.0%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water Heating
22.26
22.26
0.00
0.0%
Photovoltaic Offset
----
0.00
0.00
----
Compliance Energy Total
386.48
347.87
38.61
10.0%
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-08-06 13:07:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01
Project Name: COLBURN RESIDENCE Calculation Date/Time: 13:07, Tue, Aug 06, 2019 Page 2 of 7
Calculation Description: Title 24 Analysis Input File Name: 066 - 78101 CORONADOS CIR.ribd16x
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• --None--
Cooling System Verifications:
• -- None --
HVAC Distribution System Verifications:
• --None --
Domestic Hot Water System Verifications:
• --None --
BUILDING - FEATURES INFORMATION
01 02 03 04 05 06 07
Number of Dwelling
Number of Ventilation
Number of Water
Project Name
Conditioned Floor Area (ft)
Units
Number of Bedrooms
Number of Zones
Cooling Systems
Heating Systems
COLBURN RESIDENCE
2334
1
3
1
0
1
(ZONE INFORMATION
01
02
03
04
05
06
07
Zone Floor Area Avg. Ceiling
Zone Name
Zone Type
HVAC System Name
(ft2)
Height
Water Heating System 1
Water Heating System 2
Z- 1
Conditioned
A-AC-1
2334
9
DHW Sys 1
n/a
OPAQUE SURFACES
01
02
03
04
05
06
07 08 09
10 11
Verified
Gross Area Window & Door Tilt Wall
Existing
Name
Zone
Construction
Azimuth
Orientation
(ft)
Area (ft) (deg) Exception Status Condition
N - 478
Z- 1
Def Wall Prior to 78
0
Back
478
309.822 90 n/a
Existing No
E - 655
Z- 1
Def Wall Prior to 78
90
Right
655
52.1987 90 n/a
Existing No
S - 307
Z- 1
Def Wall Prior to 78
180
Front
307
71.6 90 n/a
Existing No
W - 656
Z- 1
Def Wall Prior to 78
270
Left
656
100.018 90 n/a
Existing No
2334
Z- 1
Def Roof Prior to '78
2334
1 n/a
Existing No
Registration Number: Registration Date[Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-08-06 13:07:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: COLBURN RESIDENCE Calculation Date/Time: 13:07, Tue, Aug 06, 2019
Calculation Description: Title 24 Analysis
Input File Name: 066 - 78101 CORONADOS CIR.ribd16x
CF1 R-PRF-01
Page 3 of 7
ATTIC
01
02
03
04
05
06
07
08
09
10
Name
Construction
Type
Roof Rise
Roof
Reflectance
Roof
Emittance
Radiant
Barrier
Cool
Roof
Status
Verified Existing
Condition
Attic Z- 1
Attic RoofZ- 1
Ventilated
4
0.1
0.85
No
No
Existing
No
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multiplier
Area (ftZ)
U-factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
3362 - A
N - 478 (Back-0)
3.3
6.1
1.009
20.0
0.51
0.24
Insect Screen (default)
New
n/a
12080 - 1
N - 478 (Back-0)
12.0
8.0
1
96.0
0.51
0.24
Insect Screen (default)
New
n/a
12068 - 2
N - 478 (Back-0)
12.0
6.7
0.995
80.0
0.51
0.24
Insect Screen (default)
New
n/a
52ANGLE- C
N - 478 (Back-0)
5.1
6.7
1.007
34.4
0.51
0.24
Insect Screen (default)
New
n/a
111068 - 3
N - 478 (Back-0)
11.9
6.7
0.996
79.4
0.51
0.24
Insect Screen (default)
New
n/a
71068 - 8
E - 655 (Right-90)
7.8
6.7
0.995 1
52.2
0.51
0.24
Insect Screen (default)
New
n/a
7968 - 6
S - 307 (Front-180)
5.0
4.0
2.58
51.6
0.51
0.24
Insect Screen (default)
New
n/a
4662 - D
W - 656 (Left-270)
4.5
6.1
1.013
27.8
0.51
0.24
Insect Screen (default)
New
n/a
71068 - 5
W - 656 (Left-270)
7.8
6.7
0.999
52.2
0.51
0.24
Insect Screen (default)
New
n/a
3362 - B
W - 656 (Left-270)
3.3
6.1
1.009
20.0
0.51
0.24
Insect Screen (default)
New
n/a
OPAQUE DOORS
01
02
03
04
05
06
Name
Side of Building
Area (ft)
U-factor
Status
Verified Existing Condition
3068 - 7
S - 307
20.0
0.50
New
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-08-06 13:07:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: COLBURN RESIDENCE Calculation Date/Time: 13:07, Tue, Aug 06, 2019
Calculation Description: Title 24 Analysis
Input File Name: 066 - 78101 CORONADOS CIR.ribdl6x
CFI R-PRF-01
Page 4 of 7
OVERHANGS AND FINS
01
02
03
04
05
06
07
08 09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
3362 - A
6
0.1
6
6
0
0
0
0
0
0
0
0
0
12080 - 1
6
0.1
6
6
0
0
0
0
0
0
0
0
0
12068 - 2
3
0.1
3
3
0
0
0
0
0
0
0
0
0
52ANGLE- C
3
0.1
3
3
0
0
0
0
0
0
0
0
0
111068-3
3
0.1
3
3
0
0
0
0
0
0
0
0
0
71068 - 8
3
0.1
3
3
0
0
0
0
0
0
0
0
0
7968 - 6
3
0.1
3
3
0
0
0
0
0
0
0
0
0
4662 -:D
3
0.1
3
3
0
0
0
0
0
0
0
0
0
71068-5
3
0.1
3
3
0
0
0
0
0
0
0
0
0
3362 - B
15
0.1
15
15
0
1 0
0
0
0
0
0
0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
I
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-factor
Assembly Layers
Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
• Roof Deck. Wood Siding/sheathing!deckina
Attic RoofZ- 1
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
Def Roof Prior to '78
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 11
0.083
Over Ceiling Joists: R-1.9 insul.
• Inside Finish: Gypsum Board
• Cavity/Frame: no insul. /2x4
Def Wall Prior to 78
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
none
0.361
Exterior Finish: 3 Coat Stucco
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Verified
Perimeter
Carpeted
Existing
Name
Zone
Area (ft2)
(ft)
Edge Insul. R-value
Fraction
Heated
Status
Condition
23342
Z- 1
2334
0.1
None
0.8
No
Existing
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-08-06 13:07:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: COLBURN RESIDENCE Calculation Date/Time: 13:07, Tue, Aug 06, 2019
Calculation Description: Title 24 Analysis
Input File Name: 066 - 78101 CORONADOS CIR.ribdl6x
CF1 R-PRF-01
Page 5 of 7
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Not Required
Not Required
Not Required
n/a
WATER HEATING SYSTEMS
01
02
03
04
I 05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
N
Status
Verified Existing
Condition
DHW Sys 1
DHW
Standard
DHW Heater 1
1
0
Existing
No
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Input Rating I
Tank
Standby
Heater
Tank
Uniform Energy
Pilot /
Insulation
Loss /
First Hour
Tank Location
Element
Number
Volume
Factor / Energy
Thermal
R-value
Recovery
Rating /
NEEA Heat Pump
or Ambient
Name
Type
Tank Type
of Units
(gal)
Factor / Efficiency
Efficiency
(Int/Ext)
Eff
Flow Rate
Brand / Model
Condition
DHW Heater 1
Gas
Small Storage
1
50
0.527 EF
— 75 kBtu/hr
0
n/a
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
Distribution
Verified Existing
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Name
Status
Condition
A-AC-1
Other Heating and Cooling
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution
I
Existing
No
System
I
I
I
System 1
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R-value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
(Ventilated and
Existing (not
4.2
Attic
Attic
None
Existing
No
n/a
System 1
Unventilated)
specified)
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-08-06 13:07:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: COLBURN RESIDENCE Calculation Date/Time: 13:07, Tue, Aug 06, 2019
Calculation Description: Title 24 Analysis
Input File Name: 066 - 78101 CORONADOS CIR.ribd16x
CF1 R-PRF-01
Page 6 of 7
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
0
0.25
Default
0
Not Required
PROJECT NOTES
--ALL INPUT DATA, HVAC EQUIPMENT, WATER HEATER EQUIP. USED IN THIS CALCULATION WAS PROVIDED BY THE PLANS PREPARER. ANY ALTERATION OR DEVIATION FROM THIS
CALCULATION WILL BE GENERAL CONTRACTOR RESPONSABILITY. -- AC CONTRACTOR SHALL VERIFY LOAD CALCULATIONS AND AC SIZING. HVAC LOADS PROVIDED IN THIS
DOCUMENT ARE APROXIMATE CALCULATIONS. -- ANY REVISION/CHANGE SHALL BE NOTIFIED TO THE ENERGY CONSULTANT TO REVISE COMPLIANCE WITH THE STANDARDS
PRIOR OF HVAC EQUIPMENT ORDER.
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149
HERS Provider:
Report Generated at: 2019-08-06 13:07:55
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: COLBURN RESIDENCE Calculation Date/Time: 17:32, Tue, Aug 06, 2019
Calculation Description: Title 24 Analysis
Input File Name: 066 - 78101 CORONADOS CIR.ribdl6x
CF1 R-PRF-01
Page 7 of 7
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Armando Chavez
Company:
Signature Date:
8/6/2019
Address:
CEA/HERS Certification Identification (If applicable):
44890 SEELEY
City/StatV:QU I NTA, CA 92253
Phone: 760 278.1840
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible DestNer Name:
Responsible Designer Signature:
Company:
Date Signed:
GLS ARCHITECTURE GROUP INC.
Address:
License:
74991 JONI DR #9
City/State
PALM DESERT, CA 92260
Phone:
760 340.3528
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2019-08-06 17:33:19
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
COLBURN RESIDENCE
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
_
California Energy Climate Zone Total Cond. Floor Area Addition
CA Climate Zone 15 2,334 0
Date
8/6/2019
F
# of Units
1
Project Address
78010 CORONADOS CIR LA QUINTA
INSULATION
Construction Type
Area
Cavity ftz Special Features
Status
Slab Unheated Slab -on -Grade
- no insulation 2,334 Perim = 0'
Existing
Roof Wood Framed Attic
R 11 2,334
Existing
Wall Wood Framed
no insulation 1,562
Existing
Door Opaque Door
no insulation 20
New
FENESTRATION
Orientation Area ft2
I Total Area: 514 Glazing Percentage: 22.0% New/Altered Average U-Factor:
U-Fac SHGC Overhang Sidefins Exterior Shades
0.51
Status
Rear (N) 116.0
0.510
0.24 6.0 none Bug Screen
New
Rear (N) 193.8
0.510
0.24 3.0 none Bug Screen
New
Right (E) 52.2
0.510
0.24 3.0 none Bug Screen
New
Front (S) 51.6
0.510
0.24 3.0 none Bug Screen
New
Left (W) 80.0
0.510
0.24 3.0 none Bug Screen
New
Left (W) 20.0
0.510
0.24 15.0 none Bug Screen
New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling Min. Eff Thermostat
Status
1 Central Furnace 78% AFUE
HVAC DISTRIBUTION
Location Heating
Split Air Conditioner 8.9 SEER Setback
Duct
Cooling Duct Location R-Value
Existing
Status
A -AC- Ducted
Ducted Attic 4.2
Existing
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution
Status
EnergyPro 7.1 by EnenqySoft User Number: 20648
ID: 19 - GLS - 066
Page 10 of 14
2016 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. *Exceptions may apply.
un mai udiluie
Building Envelope Measures:
§ 110.6(a)l:
Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ftz or less when tested per
NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-2011.'
§ 110.6(a)5:
Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a).
§ 110.6(b):
Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES
110.6-A and 110.6-B for compliance and must be caulked and/or weatherstri ed.'
§ 110.7:
Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
asketed, or weather stripped.
§ 110.8(a):
Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material.
§ 110.8(g):
Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g).
§ 110.8(i):
Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing
material must meet the requirements of § 11 0.8i when the installation of a cool roof is specified on the CF1 R.
§ 110.80):
Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043.
Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
§ 150.0(a):
insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited
to placing insulation either above or below the roof deck or on top of a drywall ceiling'
§ 150.0(b):
Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value.
Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-factor of 0.074 or
§ 150.0(c):
less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a
wood framed assembly! _
§ 150.0(d):
Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.'
§ 150.0(f):
Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light
deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 11 0.8.
Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This
§ 150.0(g)1:
requirement also applies to controlled ventilation crawls ace for buildings com2lying with the exception to § 150.0(d).
Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class 11 vapor retarder must be installed on the conditioned space side of all
§ 150.0(g)2:
insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation.
150.0
§ (q)'
Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
maximum U-factor of 0.58: or the weighted average U-factor of all fenestration must not exceed 0.58.'
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 150.0(e)lA:
Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)l B:
Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area
and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.'
§ 150.0(e)l C:
Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.'
§ 150.0(e)2:
Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of
the building, are prohibited.
Space Conditioning, Water Heating, and Plumbing System Measures:
§ 110.0-§ 110.3.
Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
appliances must be certified by the manufacturer to the Energy Commission.'
§ 110.2(a):
HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K'
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§ 110.2(b)-
must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for
compression heating is higher than the cut-off temperature for supplementary heating.'
§ 110.2(c):
Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat.`
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
§ 110.3(c)5:
meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of §
§ 110.3(c)7:
_110.3(c)5.
Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs
or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed.
§ 110.5:
Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli-
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btulhr are exem )• and pool and spa heaters.`_
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment
§ 150.0(h)l:
Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA
Manual J using design conditions specified in § 150.0(h)2.
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(h)3A:
Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any
dryer vent.
§ 150.0(h)3B:
Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by
manufacturer's instructions.
§ 150.00)1:
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must
be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a
§ 150.00)2A:
nominal diameter of 314 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter;
piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to
kitchen fixtures.'
§ 150.00)2B:
Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof
and non -crushable casing or sleeve.'
§ 150.00)2C:
Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution
piping for steam and h dronic heatin s stems or hot waters stems must meet the requirements in TABLE 120.3-A.'
§ 150.00)3:
Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by
§ 150.00)3A:
aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can
cause degradation of the material.
§ 150.00)3B:
Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a
Class I or Class II vapor retarder.
Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a
§ 150.0(n)1:
120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside
termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the
water heater, and allows natural draining without pump assistance; and a gas supply line with a ca2acity of at least 200,000 Btu/hr.
§ 150.0(n)2:
Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification
Corporation (SRCC) or by a listing agency that is approved by the Executive Director.
Ducts and Fans Measures:
§ 110.8(d)3:
Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a
contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement.
CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC
§§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSIISMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or
a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing
§ 150.0(m)1:
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than'/< inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain
ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts.'
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
§ 150.0(m)2:
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such toe is used in combination with mastic and draw bands.
§ 150.0(m)3:
Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
mastics, sealants, and other requirements specified for duct construction.
§ 150.0(m)7:
Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
automatic dampers.
§ 150.0(m)8:
Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually operated dampers in all openings to the outside, exce t combustion inlet and outlet air o enin s and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
§ 150.0(m)9:
wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation.
§ 150.0(m)10:
Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)11:
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 150.0 m 11 and Reference Residential Appendix RA3.
Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,
pressure drop, and labeling requirements of § 150.0(M)12.
2016 Low -Rise Residential Mandatory Measures Summary
Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable
space must have a hole for the placement of a static pressure probe (IiSPP), or a permanently installed static pressure probe (PSPP) in the
§ 150.0(m)13:
supply plenum. The space conditioning system must also demonstrate airflow z 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central
forced air systems.'
Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor
§150.0(o):
continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of
rp oviding whole -building ventilation.
§ 150.0(o)1A:
Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.7.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
§ 110.4(a):
that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heating.'
§ 110.4(b)1:
Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated
suction and return lines or built-in or built-up connections to allow for future solar heating.
§ 110.4(b)2:
Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b)3:
Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
will allow all pumps to be set or programmed to run only during off-peak electric demand periods.
§ 110.5:
Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
150.0
§ (p)'
Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
rate, pipin2, filters, and valves.'
Lighting Measures:
§ 110.9:
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
of§ 110.9.*
§ 110.9(e):
JAB High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must
be certified to the Energy Commission according to Reference Joint Appendix JAB.
§ 150.0(k)1A:
Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or
§ 150.0(k)1 B:
other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fan speed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)9 C
labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C. A JA8-2016-E light source rated for
elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings.
§ 150.0(k)1 D:
Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than
20 kHz.
Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no
§ 150.0(k)1 E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled
by vacancy sensors.
§ 150.0(k)1 F:
Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
must meet the applicable requirements of § 150.0(k).*
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply
§ 150.0(k)1 G:
with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix
JA8.'
§ 150.0(k)1 H:
Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E."
§ 150.0(k)2A:
Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B:
Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems'
§ 150.0(k)2C:
Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually
switched ON and OFF.
§ 150.0(k)2D:
Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with
150.0(k).
§ 150.0(k)2F:
Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it:
§ 150.0(k)2G:
functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of §
130.5 ; and meets all other requirements in § 150.0 k)2_
Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the
§ 150.0(k)2H:
following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of §
130.5(f); and all other requirements in § 150.0(k)2.
§ 150.0(k)21:
Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
provides the functionality_of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(k;_-J:
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
be controlled !sy a vacancy sensor.
§ 150.0(k)2K:
Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with
Reference Joint Appendix JA8, exc t luminaires in closets less than 70 square feet and luminaires in hallways.'
§ 150.0(k)2L:
Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A:
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item
§ 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or
EMCS).
Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies,
§ 150.0(k)3B:
and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with
either 150.0 k 3A or with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)3C:
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by
150.0 k 3B or i50.0 k 3D must cornply with the applicable requirements in §J 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)3D:
Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more
vehicles per site must com2ly with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0.
§ 150.0(k)4:
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
power as determined according to 130.0(c).
§ 150.0(k)5:
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1. 130.4, 140.6, and 141.0.
Interior Common Areas of Low-rise MultkFamily Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A:
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be hiqh efficacy luminaires and controlled by an occupant sensor.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must:
§ 150.0(k)6B:
i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1.
application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the
requirements of § 110.10(b) through § 110.10(e).
§ 110.10(a)2:
_
Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d).
Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local
jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet
each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas
§ 110.10(b)1.
greater than 10,000 square feet.
For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250
square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang
of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less
than 15 percent of the total roof area of the building excluding any skylight area.`
§ 110.10(b)2:
Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.'
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)36:
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone, measured in the vertical plane.'
§ 110.10(b)4:
Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof
dead load and roof live load must be clearly indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for
§ 110.10(c):
routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system.
§ 110.10(d):
Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
110.10 c must be provided to the occupant.
§ 110.10(e)1:
Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2:
breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or
main circuit location; and permanently marked as "For Future Solar Electric".
June 12, 2019
City of La Quinta
Design and Development Department
Building Division
78-495 Calle Tampico
La Quinta, CA 92253
Re: Trades Pulling Permits
Location: 78010 Coronados Circle, La Quinta, CA
92253
APN# 64621001
Greetings La Quinta Building Division,
Per your request I am submitting names of contractors
working at my residence (78010 Coronados Circle, La
Quinta, CA 92253) who already have/or who are in the
process of submitting their applications for permits.
I am also noting the work that they are doing.
Tor s Electt'i #9 4 066
Upgrades to Electrical Sub Panel, Replace existing interior
lighting with LED Fixtures. Replace courtyard lighting
with LED Fixtures.
O ali Mecl�a�iical l'lu3nk�in #9g 23620
Run new water lines and gas lines to appliances, Replace
Kitchen and Bathroom Sinks and faucets, replace Master
Shower Valves and replace (3) Toilets. w
o
�a.n _Ca_r n r _ # 1009748
f_� l'ti,Toucla
Replace Original Sliding Doors and Picture Windows with '—
more energy efficient sliding doors/windows. Relocate
and reinstall existing front door. Replace kitchen and �
bathroom cabinets.
If you have further questions please direct them to my local
Project Manager/Designer: Nicholas Hertneck at 310 854
Than ,
David Colburn, Homeowner
600 North Fairbanks, #2402
Chicago, IL 60611
YOI,i may ct(so co.(I me 'ia Veri'� = 84?-691-g09`f .