Loading...
BRES2019-020278-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type/Subtype: Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: ELMER GARCIA 67375 MEDANO ROAD CATHEDRAL CITY, CA 92234 Tjhr44uQu&rw DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT BUILDING RESIDENTIAL/REMODEL BRES2019-0202 78010 CORONADOS CIR CIR 646210001 COLBURN / REMODEL + CONVERT 96SF LIVING SPACE TO PATIO VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Owner: DAVID COLBURN 78010 CORONADOS CIRCLE LA QUINTA, CA 92253 Date: 8/22/2019 $1.00 Contractor: AUG `' t �f1�9D MODERN TOUCH CONSTRUCTION U 67685 BROKEN ARROW LANE F D DESERT HOT SPRINGS, CA 92234 CITY OF ;AQUiNTA DESIGN &DEVELOPMENT DEPARTMENT (760)835-2777 Llc. No.: 1004355 LICENSED CONTRACTOR'S DECLARATION hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 1004355 Date: d 247 Contractoc.�0_1/jri�, OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner; CONSTRUCTION LENDING AGENCY hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Na Lender's WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of th rk for which this permit is issued. . I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: NORGUARD INSURANCE COMPANY Policy Number: MOWC031852 _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date:S Appllca'4T' a WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above - mentioned property for inspection purposes. Date: �Z Signature (Applicant orAgenk. e I I Z_ Date: 8/22/2019 Application Number: BRES2019-0202 Property Address: 78010 CORONADOS CIR CIR APN: 646210001 Application Description: COLBURN / REMODEL + CONVERT 965F LIVING SPACE TO PATIO Property Zoning: Application Valuation: $1.00 Applicant: ELMER GARCIA 67375 MEDANO ROAD CATHEDRAL CITY, CA 92234 Owner: DAVID COLBURN 78010 CORONADOS CIRCLE LA QUINTA, CA 92253 Contractor: MODERN TOUCH CONSTRUCTION 67685 BROKEN ARROW LANE DESERT HOT SPRINGS, CA 92234 (760)835-2777 Llc. No.: 1004355 Detail: COLBURN / REMODEL - CONVERT 965F OF LIVING SPACE TO EXTERIOR PATIO AREA, REPLACE ALL WINDOWS AND DOORS, NEW PLUMBING FIXTURES THROUGHOUT, NEW LIGHTING AT BATHS AND KITCHEN. THIS APPROVAL DOES NOT INCLUDE THE REPLACEMENT OF HVAC EQUIPMENT, WATER HEATER, OR ELECTRICAL SERVICE PANEL. 2016 CALIFORNIA BUILDING CODES. DESCRIPTION ACCOUNT CITY AMOUNT HOURLY CHARGE - ESGIL CIVIL ENGINEER 101-0000-42600 2 $210.00 Total Paid for BLDG CITY STAFF - PER HOUR: $210.00 DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 I Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES, FIRST 20 101-0000-42403 0 $26.68 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES, FIRST 20 PC 101-0000-42600 0 $26.68 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES/FIXTURES, ADDITIONAL 101-0000-42403 0 $120.15 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES/FIXTURES, ADDITIONAL PC 101-0000-42600 0 $30.15 Total Paid for ELECTRICAL: $203.66 DESCRIPTION ACCOUNT CITY AMOUNT EXHAUST HOOD 101-0000-42402 0 $13.34 DESCRIPTION ACCOUNT CITY AMOUNT EXHAUST HOOD PC 101-0000-42600 0 $5.34 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN 101-0000-42402 0 $40.02 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN PC 101-0000-42600 0 $16.02 Total Paid for MECHANICAL: $74.72 DESCRIPTION ACCOUNT CITY AMOUNT PLAN CHECK DEPOSIT - ADDITION/REMODEL 101-0000-42600 1 $125.00 Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $125.00 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $146.74 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $146.74 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 1-4 OUTLETS 101-0000-42401 0 $13.34 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 1-4 OUTLETS PC 101-0000-42600 0 $26.68 DESCRIPTION ACCOUNT CITY AMOUNT WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $13.34 DESCRIPTION ACCOUNT CITY AMOUNT l WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $13.34 Total Paid for PLUMBING FEES: $360.18 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($125.00) DESCRIPTION ACCOUNT CITY AMOUNT REMODEL, EA ADDITIONAL 500 SF 101-0000-42400 0 $120.05 DESCRIPTION ACCOUNT CITY AMOUNT REMODEL, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $96.05 DESCRIPTION ACCOUNT CITY AMOUNT REMODEL, FIRST 100 SF 101-0000-42400 0 $54.43 DESCRIPTION ACCOUNT CITY AMOUNT REMODEL, FIRST 500 SF PC 101-0000-42600 0 $23.89 DESCRIPTION ACCOUNT CITY AMOUNT REMODEL, FIRST 500 SF PC 101-0000-42600 1 0 $125.00 Total Paid for REMODEL: $294.42 DESCRIPTION ACCOUNT CITY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $0.50 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $0.50 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 4: Architect/Engineer Name: Address: City, St, Zip Telephone: Email State Lic: City Bus Lic: Construction Grading: Bedrooms: 1 Stories: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 Occupancy: # Units: OFFICE NSE ONLY # Submittal Required Received Plan Sets I Structural Calcs Truss Calcs 1 Title 24 Calcs Y' Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval i City Business License — GEM of the DESERT 78495 CALLE TAMPICO BUILDING DIVISION LA QUINTA, CALIFORNIA 92253 (760) 777-7125 W W W.LAQUINTACA.GOV FAX (760) 777-701 1 TRANSMITTAL TO: ❑INTERWEST QllSGIL ❑HR GREEN ❑OTHER ❑COMPLETE PLAN CHECK I•RUGTURAL ONLY 1 TODAY'S DATE: G �. � DUE DATE: ? 3 201 q PERMIT NUMBER: PROJECT ADDRESS: CIDIONA00S G APPLICANT NAME: 96L.MEtL q,gAA M SUBMITTAL ROUND:_ BIN NUMBER: n L90 Fjftt4T Coy NTF,iYi� INCLUDED HEREWITH: PLANS ❑REDLINED PLANS C� RUCT ❑REDLINED STRUCT ❑TRUSS ❑REDLINED TRUSS ❑SOILS ❑REDLINED SOILS ❑ENERGY ❑REVISED ENERGY ❑CORRECTION LIST ❑REVISED PLANS ❑REVISED STRUCT ❑REVISED TRUSS ❑REVISED SOILS ❑CUSTOMER RESPONSES R' OTES _ SFIt ! IY' - 1.1 Ml�k � L 7 -• �� g ❑APPROVED PLANS ❑APPROVED STRUCT ❑APPROVED TRUS []APPROVED SOILS LA QUINTA BRES2019-0202 7/8/2019 [DO NOT PAY— THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: LA QUINTA PLAN CHECK #.: BRES2019-0202 PREPARED BY: Bert Domingo DATE: 7/8/2019 BUILDING ADDRESS: 78010 CORONADOS CIRCLE BUILDING OCCUPANCY: R 3 BUILDING PORTION AREA ( Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code LQ Manual Input 1997 UBC Building Permit Fee 1997 IJRC Plan Cherk Fee 1 Type of Review: ❑ Repetitive Fee Repeats " Based on hourly rate L : Complete Review �,❑ Otthppe������r�� L_±!_ EsGill Fee ❑ Structural Only 2 Hrs. @ $105.00 $2 00 Comments: In addition to the above fee, an additional fee of $ is due ( hour @ $ /hr.) for the CalGreen review. Sheet 1 of 1 EsGil A SAF` buM Company DATE: 7/8/2019 ❑ APPLICANT ❑ JURIS. JURISDICTION: LA QUINTA PLAN CHECK #.: BRES2019-0202 SET: I PROJECT ADDRESS: 78010 CORONADOS CIRCLE PROJECT NAME: SFD REMODEL FOR COLBURN (STRUCTURAL ONLY) ❑ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. ❑ The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. ® The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ❑ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. ® The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ❑ The applicant's copy of the check list has been sent to: ® EsGil staff did not advise the applicant that the plan check has been completed. ❑ EsGil staff did advise the applicant that the plan check has been completed. Person contacted. l f Telephone #: Date contacted: 1`�� (by'.- ] Email: Mail Telephone Fax In Person ❑ REMARKS: By: Bert Domingo Enclosures: EsGil 6/27/2019 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 LA QUINTA BRES2019-0202 7/8/2019 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK #.: BRES2019-0202 JURISDICTION: LA QUINTA PROJECT ADDRESS: 78010 CORONADOS CIRCLE FLOOR AREA: REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 7/8/2019 FOREWORD (PLEASE READ): STORIES: HEIGHT: DATE PLANS RECEIVED BY ESGIL CORPORATION: 6/27/2019 PLAN REVIEWER: Bert Domingo This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2016 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC, 2015 UPC, 2015 UMC and 2014 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list or a co where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. LA QUINTA BRES2019-0202 7/8/2019 ADO NOT PAY— THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: LA QUINTA PLAN CHECK #.: BRES2019-0202 PREPARED BY: Bert Domingo DATE: 7/8/2019 BUILDING ADDRESS: 78010 CORONADOS CIRCLE BUILDING OCCUPANCY: R 3 BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code JLQ Manual Input 1997 UBC Building Permit Fee 1997 UBC Plan Check Fee Type of Review: ❑ Complete Review Structural Only ❑ Repetitive Fee ❑ Other Repeats Hourly 2 Hrs. @ " EsGil Fee $105.00 " Based on hourly rate Comments: In addition to the above fee, an additional fee of $ $ /hr.) for the CalGreen review. is due ( hour @ Sheet 1 of 1 LA QUINTA BRES2019-0202 7/8/2019 PLANS Please make all corrections and submit two new complete sets of prints, to: The jurisdiction's building department. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 3. Plans deviating from conventional wood frame construction shall have the structural portions signed and sealed by the California state licensed engineer or architect responsible for their preparation, along with structural calculations. (California Business and Professions Code). 4. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2016 California Residential Code, which adopts the 2015 IRC, 2015 UMC, 2015 UPC and the 2014 NEC. Section R106.1. MISCELLANEOUS 5. Please show the specifications of the recommended structural elements of the remodel. 6. It seems that the roofing materials is tile roof. Please show the weight of such roofing materials. 7. Please have the structural engineer stamp and signed the structural framing system to include the foundation. LA QUINTA BRES2O19-0202 7/8/2019 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes ❑ No ❑ The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bert Domingo at EsGil. Thank you. GEM of the DESERT 78495 CALL'E TAMPICO BUILDING DIVISION LA QUINTA, CALIFORNIA 92253 (760) 777-7125 WWW.LAQUINTACA.GOV FAX (760) 777-7011 TRANSMITTAL TO: ❑INTERWEST A:SGIL ❑HR GREEN ❑OTHER ❑COMPLETE PLAN CHECK jWSTRUCTURAL ONLY ATTN TODAY'S DATE: it/ 4f DUE DATE:�� PERMIT NUMBER: j ; �• ID;• D PROJECT ADDRESS: 140 —9 �A � r APPLICANT NAME: --6tA"&-4A C- SUBMITTAL ROUND: 2ad— __ BIN NUMBER: INCLUDED HEREWITH: ❑PLANS ENREDLINED PLANS ❑STRUCT JUREDLINED STRUCT ❑TRUSS ❑REDLINED TRUSS ❑SOILS ❑REDLINED SOILS ❑ENERGY ❑REVISED ENERGY CORRECTION LIST VOTES [4iEVISED PLANS [NREVISED STRUCT ❑REVISED TRUSS ❑REVISED SOILS (NC;USTOMER RESPONSES [-]APPROVED PLANS []APPROVED STRUCT []APPROVED TRUSS ❑APPROVED SOILS ■ DATE: 8/19/2019 JURISDICTION: LA QUINTA v EsGil ❑ APPLICANT ❑ JURIS. PLAN CHECK #.: BRES2019-0202 SET: II PROJECT ADDRESS: 78010 CORONADOS CIRCLE PROJECT NAME: SFD REMODEL FOR COLBURN (STRUCTURAL ONLY) ® The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's BUILDING codes. ❑ The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. ❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ❑ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. ❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ❑ The applicant's copy of the check list has been sent to: ® EsGil staff did not advise the applicant that the plan check has been completed. ❑ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: / 4 Telephone #: Date contacted: (by. ) Email: Mail Telephone Fax In Person ❑ REMARKS: By: Bert Domingo Enclosures: EsGil 8/12/2019 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858).560-1576 June 12, 2019 City of La Quinta Design and Development Department Building Division 78-495 Calle Tampico La Quinta, CA 92253 Re: Trades Pulling Permits Location: 78010 Coronados Circle, La Quinta, CA 92253 APN# 64621001 Greetings La Quinta Building Division, Per your request I am submitting names of contractors working at my residence (78010 Coronados Circle, La Quinta, CA 92253) who already have/or who are in the process of submitting their applications for permits. I am also noting the work that they are doing. Torres Electric #994066 Upgrades to Electrical Sub Panel, Replace existing interior lighting with LED Fixtures. Replace courtyard lighting with LED Fixtures. duality Mechanical Plumbina #923620 Run new water lines and gas lines to appliances, Replace Kitchen and Bathroom Sinks and faucets, replace Master Shower Valves and replace (3) Toilets. LU N Artisan Touch_Carrzentry # 1009749 Replace Original Sliding Doors and Picture Windows with � a, L U '— more energy efficient sliding doors/windows. Relocate and reinstall existing front door. Replace kitchen and � bathroom cabinets. If you have further questions please direct them to my local Project Manager/Designer: Nicholas Hertneck at 310 854 4 2805. Than , David Colburn, Homeowner 600 North Fairbanks, #2402 Chicago, IL 60611 Y01A ►nc�Y a (so ca f f me 4b Ve►'i '� � 8 4-7 - 01-gOqq 'Th a nle YOU BUILDING ENERGY ANALYSIS REPORT PROJECT: COLBURN RESIDENCE 78010 CORONADOS CIR LA QUINTA, CA 92253 Project Designer: GLS ARCHITECTURE GROUP INC. 74991 JONI DR #9 PALM DESERT, CA 92260 760 340.3528 CATY" OF LA QURA A EUILDING DIVISION Report Prepared by: REVIEWED FOR Y CODE Armando Chavez + C MPLIANCE OATS ; �!'� BY 44890 SEELEY LA QUINTA, CA 92253 760 278.1840 RECEIVED AUG 0 9 2019 CITY OF LA QUINTA DESIGN AND DEVELOPMENT DEPARTMENT Job Number: 19-GLS-066 Date: 8/6/2019 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. I TABLE OF CONTENTS I Cover Page Table of Contents Form CF-1 R-PRF-01-E Certificate of Compliance Form RMS-1 Residential Measures Summary Form MF-1 R Mandatory Measures Summary 1 2 3 10 11 7.1 by EnergySoft JobNumber. ID: 19 - GLS - 066 User Number: 20648 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: COLBURN RESIDENCE Calculation Description: Title 24 Analysis Calculation Date/Time: 13:07, Tue, Aug 06, 2019 Input File Name: 066 - 78101 CORONADOS CIR.ribd16x Page 1 of 7 GENERAL INFORMATION 01 Project Name COLBURN RESIDENCE 02 Calculation Description Title 24 Analysis 03 Project Location 78010 CORONADOS CIR 04 City LA QUINTA 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 09 Software Version CBECC-Res 2016.3.1 (1019) 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 180 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 16 Total Cond. Floor Area (ftZ) Slab Area (ftZ) 2334 2334 15 17 Number of Zones Number of Stories 1 1 18 Addition Cond. Floor Area (ftZ) 0 19 Natural Gas Available No E20 Addition Slab Area (ftZ) 1 0 21 Glazing Percentage (%) 22.0% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ftZ-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 21.09 23.61 -2.52 -11.9% Space Cooling 343.13 302.00 41.13 12.0% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 22.26 22.26 0.00 0.0% Photovoltaic Offset ---- 0.00 0.00 ---- Compliance Energy Total 386.48 347.87 38.61 10.0% REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Window overhangs and/or fins Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-08-06 13:07:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: COLBURN RESIDENCE Calculation Date/Time: 13:07, Tue, Aug 06, 2019 Page 2 of 7 Calculation Description: Title 24 Analysis Input File Name: 066 - 78101 CORONADOS CIR.ribd16x HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • --None-- Cooling System Verifications: • -- None -- HVAC Distribution System Verifications: • --None -- Domestic Hot Water System Verifications: • --None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Number of Dwelling Number of Ventilation Number of Water Project Name Conditioned Floor Area (ft) Units Number of Bedrooms Number of Zones Cooling Systems Heating Systems COLBURN RESIDENCE 2334 1 3 1 0 1 (ZONE INFORMATION 01 02 03 04 05 06 07 Zone Floor Area Avg. Ceiling Zone Name Zone Type HVAC System Name (ft2) Height Water Heating System 1 Water Heating System 2 Z- 1 Conditioned A-AC-1 2334 9 DHW Sys 1 n/a OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 11 Verified Gross Area Window & Door Tilt Wall Existing Name Zone Construction Azimuth Orientation (ft) Area (ft) (deg) Exception Status Condition N - 478 Z- 1 Def Wall Prior to 78 0 Back 478 309.822 90 n/a Existing No E - 655 Z- 1 Def Wall Prior to 78 90 Right 655 52.1987 90 n/a Existing No S - 307 Z- 1 Def Wall Prior to 78 180 Front 307 71.6 90 n/a Existing No W - 656 Z- 1 Def Wall Prior to 78 270 Left 656 100.018 90 n/a Existing No 2334 Z- 1 Def Roof Prior to '78 2334 1 n/a Existing No Registration Number: Registration Date[Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-08-06 13:07:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: COLBURN RESIDENCE Calculation Date/Time: 13:07, Tue, Aug 06, 2019 Calculation Description: Title 24 Analysis Input File Name: 066 - 78101 CORONADOS CIR.ribd16x CF1 R-PRF-01 Page 3 of 7 ATTIC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condition Attic Z- 1 Attic RoofZ- 1 Ventilated 4 0.1 0.85 No No Existing No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ftZ) U-factor SHGC Exterior Shading Status Verified Existing Condition 3362 - A N - 478 (Back-0) 3.3 6.1 1.009 20.0 0.51 0.24 Insect Screen (default) New n/a 12080 - 1 N - 478 (Back-0) 12.0 8.0 1 96.0 0.51 0.24 Insect Screen (default) New n/a 12068 - 2 N - 478 (Back-0) 12.0 6.7 0.995 80.0 0.51 0.24 Insect Screen (default) New n/a 52ANGLE- C N - 478 (Back-0) 5.1 6.7 1.007 34.4 0.51 0.24 Insect Screen (default) New n/a 111068 - 3 N - 478 (Back-0) 11.9 6.7 0.996 79.4 0.51 0.24 Insect Screen (default) New n/a 71068 - 8 E - 655 (Right-90) 7.8 6.7 0.995 1 52.2 0.51 0.24 Insect Screen (default) New n/a 7968 - 6 S - 307 (Front-180) 5.0 4.0 2.58 51.6 0.51 0.24 Insect Screen (default) New n/a 4662 - D W - 656 (Left-270) 4.5 6.1 1.013 27.8 0.51 0.24 Insect Screen (default) New n/a 71068 - 5 W - 656 (Left-270) 7.8 6.7 0.999 52.2 0.51 0.24 Insect Screen (default) New n/a 3362 - B W - 656 (Left-270) 3.3 6.1 1.009 20.0 0.51 0.24 Insect Screen (default) New n/a OPAQUE DOORS 01 02 03 04 05 06 Name Side of Building Area (ft) U-factor Status Verified Existing Condition 3068 - 7 S - 307 20.0 0.50 New No Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-08-06 13:07:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: COLBURN RESIDENCE Calculation Date/Time: 13:07, Tue, Aug 06, 2019 Calculation Description: Title 24 Analysis Input File Name: 066 - 78101 CORONADOS CIR.ribdl6x CFI R-PRF-01 Page 4 of 7 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 3362 - A 6 0.1 6 6 0 0 0 0 0 0 0 0 0 12080 - 1 6 0.1 6 6 0 0 0 0 0 0 0 0 0 12068 - 2 3 0.1 3 3 0 0 0 0 0 0 0 0 0 52ANGLE- C 3 0.1 3 3 0 0 0 0 0 0 0 0 0 111068-3 3 0.1 3 3 0 0 0 0 0 0 0 0 0 71068 - 8 3 0.1 3 3 0 0 0 0 0 0 0 0 0 7968 - 6 3 0.1 3 3 0 0 0 0 0 0 0 0 0 4662 -:D 3 0.1 3 3 0 0 0 0 0 0 0 0 0 71068-5 3 0.1 3 3 0 0 0 0 0 0 0 0 0 3362 - B 15 0.1 15 15 0 1 0 0 0 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 I Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 • Roof Deck. Wood Siding/sheathing!deckina Attic RoofZ- 1 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 Def Roof Prior to '78 attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 11 0.083 Over Ceiling Joists: R-1.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: no insul. /2x4 Def Wall Prior to 78 Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.361 Exterior Finish: 3 Coat Stucco SLAB FLOORS 01 02 03 04 05 06 07 08 09 Verified Perimeter Carpeted Existing Name Zone Area (ft2) (ft) Edge Insul. R-value Fraction Heated Status Condition 23342 Z- 1 2334 0.1 None 0.8 No Existing No Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-08-06 13:07:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: COLBURN RESIDENCE Calculation Date/Time: 13:07, Tue, Aug 06, 2019 Calculation Description: Title 24 Analysis Input File Name: 066 - 78101 CORONADOS CIR.ribdl6x CF1 R-PRF-01 Page 5 of 7 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 I 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction N Status Verified Existing Condition DHW Sys 1 DHW Standard DHW Heater 1 1 0 Existing No WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Input Rating I Tank Standby Heater Tank Uniform Energy Pilot / Insulation Loss / First Hour Tank Location Element Number Volume Factor / Energy Thermal R-value Recovery Rating / NEEA Heat Pump or Ambient Name Type Tank Type of Units (gal) Factor / Efficiency Efficiency (Int/Ext) Eff Flow Rate Brand / Model Condition DHW Heater 1 Gas Small Storage 1 50 0.527 EF — 75 kBtu/hr 0 n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 Distribution Verified Existing SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Name Status Condition A-AC-1 Other Heating and Cooling Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution I Existing No System I I I System 1 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R-value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic (Ventilated and Existing (not 4.2 Attic Attic None Existing No n/a System 1 Unventilated) specified) Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-08-06 13:07:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: COLBURN RESIDENCE Calculation Date/Time: 13:07, Tue, Aug 06, 2019 Calculation Description: Title 24 Analysis Input File Name: 066 - 78101 CORONADOS CIR.ribd16x CF1 R-PRF-01 Page 6 of 7 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 0.25 Default 0 Not Required PROJECT NOTES --ALL INPUT DATA, HVAC EQUIPMENT, WATER HEATER EQUIP. USED IN THIS CALCULATION WAS PROVIDED BY THE PLANS PREPARER. ANY ALTERATION OR DEVIATION FROM THIS CALCULATION WILL BE GENERAL CONTRACTOR RESPONSABILITY. -- AC CONTRACTOR SHALL VERIFY LOAD CALCULATIONS AND AC SIZING. HVAC LOADS PROVIDED IN THIS DOCUMENT ARE APROXIMATE CALCULATIONS. -- ANY REVISION/CHANGE SHALL BE NOTIFIED TO THE ENERGY CONSULTANT TO REVISE COMPLIANCE WITH THE STANDARDS PRIOR OF HVAC EQUIPMENT ORDER. Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 HERS Provider: Report Generated at: 2019-08-06 13:07:55 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: COLBURN RESIDENCE Calculation Date/Time: 17:32, Tue, Aug 06, 2019 Calculation Description: Title 24 Analysis Input File Name: 066 - 78101 CORONADOS CIR.ribdl6x CF1 R-PRF-01 Page 7 of 7 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Armando Chavez Company: Signature Date: 8/6/2019 Address: CEA/HERS Certification Identification (If applicable): 44890 SEELEY City/StatV:QU I NTA, CA 92253 Phone: 760 278.1840 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible DestNer Name: Responsible Designer Signature: Company: Date Signed: GLS ARCHITECTURE GROUP INC. Address: License: 74991 JONI DR #9 City/State PALM DESERT, CA 92260 Phone: 760 340.3528 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2019-08-06 17:33:19 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name COLBURN RESIDENCE Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration _ California Energy Climate Zone Total Cond. Floor Area Addition CA Climate Zone 15 2,334 0 Date 8/6/2019 F # of Units 1 Project Address 78010 CORONADOS CIR LA QUINTA INSULATION Construction Type Area Cavity ftz Special Features Status Slab Unheated Slab -on -Grade - no insulation 2,334 Perim = 0' Existing Roof Wood Framed Attic R 11 2,334 Existing Wall Wood Framed no insulation 1,562 Existing Door Opaque Door no insulation 20 New FENESTRATION Orientation Area ft2 I Total Area: 514 Glazing Percentage: 22.0% New/Altered Average U-Factor: U-Fac SHGC Overhang Sidefins Exterior Shades 0.51 Status Rear (N) 116.0 0.510 0.24 6.0 none Bug Screen New Rear (N) 193.8 0.510 0.24 3.0 none Bug Screen New Right (E) 52.2 0.510 0.24 3.0 none Bug Screen New Front (S) 51.6 0.510 0.24 3.0 none Bug Screen New Left (W) 80.0 0.510 0.24 3.0 none Bug Screen New Left (W) 20.0 0.510 0.24 15.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 78% AFUE HVAC DISTRIBUTION Location Heating Split Air Conditioner 8.9 SEER Setback Duct Cooling Duct Location R-Value Existing Status A -AC- Ducted Ducted Attic 4.2 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 7.1 by EnenqySoft User Number: 20648 ID: 19 - GLS - 066 Page 10 of 14 2016 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. *Exceptions may apply. un mai udiluie Building Envelope Measures: § 110.6(a)l: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ftz or less when tested per NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-2011.' § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES 110.6-A and 110.6-B for compliance and must be caulked and/or weatherstri ed.' § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 11 0.8i when the installation of a cool roof is specified on the CF1 R. § 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043. Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling' § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-factor of 0.074 or § 150.0(c): less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly! _ § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.' § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 11 0.8. Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This § 150.0(g)1: requirement also applies to controlled ventilation crawls ace for buildings com2lying with the exception to § 150.0(d). Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class 11 vapor retarder must be installed on the conditioned space side of all § 150.0(g)2: insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation. 150.0 § (q)' Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-factor of 0.58: or the weighted average U-factor of all fenestration must not exceed 0.58.' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)lA: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)l B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.' § 150.0(e)l C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0-§ 110.3. Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the Energy Commission.' § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b)- must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating.' § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat.` Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § § 110.3(c)7: _110.3(c)5. Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed. § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btulhr are exem )• and pool and spa heaters.`_ Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)l: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J using design conditions specified in § 150.0(h)2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any dryer vent. § 150.0(h)3B: Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's instructions. § 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 314 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures.' § 150.00)2B: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve.' § 150.00)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution piping for steam and h dronic heatin s stems or hot waters stems must meet the requirements in TABLE 120.3-A.' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the material. § 150.00)3B: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class II vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)1: 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a ca2acity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a listing agency that is approved by the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSIISMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)1: (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than'/< inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts.' Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such toe is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, exce t combustion inlet and outlet air o enin s and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0 m 11 and Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure drop, and labeling requirements of § 150.0(M)12. 2016 Low -Rise Residential Mandatory Measures Summary Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (IiSPP), or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow z 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central forced air systems.' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(o): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of rp oviding whole -building ventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.' § 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines or built-in or built-up connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. 150.0 § (p)' Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, pipin2, filters, and valves.' Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of§ 110.9.* § 110.9(e): JAB High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must be certified to the Energy Commission according to Reference Joint Appendix JAB. § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fan speed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)9 C labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings. § 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)1 F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0(k).* Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1 G: with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix JA8.' § 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E." § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5 ; and meets all other requirements in § 150.0 k)2_ Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5(f); and all other requirements in § 150.0(k)2. § 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it provides the functionality_of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(k;_-J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled !sy a vacancy sensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JA8, exc t luminaires in closets less than 70 square feet and luminaires in hallways.' § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMCS). Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either 150.0 k 3A or with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0 k 3B or i50.0 k 3D must cornply with the applicable requirements in §J 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site must com2ly with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of power as determined according to 130.0(c). § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1. 130.4, 140.6, and 141.0. Interior Common Areas of Low-rise MultkFamily Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be hiqh efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1. application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the requirements of § 110.10(b) through § 110.10(e). § 110.10(a)2: _ Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1. greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.` § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment.' Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)36: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane.' § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through 110.10 c must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and permanently marked as "For Future Solar Electric". June 12, 2019 City of La Quinta Design and Development Department Building Division 78-495 Calle Tampico La Quinta, CA 92253 Re: Trades Pulling Permits Location: 78010 Coronados Circle, La Quinta, CA 92253 APN# 64621001 Greetings La Quinta Building Division, Per your request I am submitting names of contractors working at my residence (78010 Coronados Circle, La Quinta, CA 92253) who already have/or who are in the process of submitting their applications for permits. I am also noting the work that they are doing. Tor s Electt'i #9 4 066 Upgrades to Electrical Sub Panel, Replace existing interior lighting with LED Fixtures. Replace courtyard lighting with LED Fixtures. O ali Mecl�a�iical l'lu3nk�in #9g 23620 Run new water lines and gas lines to appliances, Replace Kitchen and Bathroom Sinks and faucets, replace Master Shower Valves and replace (3) Toilets. w o �a.n _Ca_r n r _ # 1009748 f_� l'ti,Toucla Replace Original Sliding Doors and Picture Windows with '— more energy efficient sliding doors/windows. Relocate and reinstall existing front door. Replace kitchen and � bathroom cabinets. If you have further questions please direct them to my local Project Manager/Designer: Nicholas Hertneck at 310 854 Than , David Colburn, Homeowner 600 North Fairbanks, #2402 Chicago, IL 60611 YOI,i may ct(so co.(I me 'ia Veri'� = 84?-691-g09`f . 7h ank You