Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BSOL2019-0011
78-495 CALLE TAMPICO " p D � VOICE (760) 777-7125 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 8/21/2019 Permit Type/Subtype: SOLAR/RESIDENTIAL LESS THAN 1OKW Owner: Application Number: BSOL2019-0011 OSCAR CHAVEZ Property Address: 52290 AVENIDA VALLEJO 52290 AVENIDA VALLEJO APN: 773263002 LA QUINTA, CA 92253 Application Description: CHAVEZ / 4.27KW PV SYSTEM - (14) 305W PANELS+ (1) INVERTER Property Zoning: Application Valuation: $17,500.00 Applicant: Contractor: MICHAEL TONEY / INFINITY ENERGY INC D INFINITY ENERGY INC 3855 ATHERTON ROAD 3855 ATHERTON ROAD ROCKLIN, CA 95765 AUG 21 2019 D ROCKLIN, CA 95765 (916)244-2513 CITY OF LAQUINTA LIc. No.: 998627 DESIGN & DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. Licensee /Class: B, C10 m License No.: 998627 Date:�e� , ' k 1 Contractor:�� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: () I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). () I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of th work for which this permit is issued. AXI have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued My workers' compensation insurance carrier and policy number are: Carrier: yTATE COMPENSATfOI+F INSURANCE FUND _ Policy Number: 9146613 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application, 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. Date: l Signature (Applicant or Agent):F'VU, Date: 8/21/2019 Application Number: BSOL2019-0011 Property Address: 52290 AVENIDA VALLEJO APN: 773263002 Application Description: CHAVEZ / 4.27KW PV SYSTEM - (14) 305W PANELS+ (1) INVERTER Property Zoning: Application Valuation: $17,500.00 Applicant: MICHAEL TONEY/ INFINITY ENERGY INC 3855 ATHERTON ROAD ROCKLIN, CA 95765 Owner: OSCAR CHAVEZ 52290 AVENIDA VALLEJO LA QUINTA, CA 92253 Contractor: INFINITY ENERGY INC 3855 ATHERTON ROAD ROCKLIN, CA 95765 (916)244-2513 Llc. No.: 998627 Detail: CHAVEZ / 4.27kW SOLAR ARRAY - (14) 305W LONGI LR6-60PB-305M PANELS W/ (1) SOLAREDGE SE3000H-US INVERTER [252SF] 2016 CALIFORNIA ELECTRICAL CODE. (888) 244-2513 To whom it may concern, energy goinfinityenergy.com Lie # 998627 Martin Rayner. has the right and my permission to act as an agent of Infinity Energy Inc. in regards to matters concerning business licenses, building permits, signing plansets and all other related activities. Bryson Solomon i(S3 r-"0) 870-6446 Owner Infinity Energy Inc. j i It energy DocuSign Envelope PD: DEE4FA2B-ED16-4C48-9719-9E29CCD269EC 1-.4de energy SOLAR ENERGY SYSTEM DISCLOSURE DOCUMENT COVER PAGE The TOTAL COST for the solar energy system (including financing and energy / power cost if applicable) is:17500 To make a complaint against a contractor who installs this system and/or the home improvement salesperson who sold this system, contact the Contractors State License Board (CSLB) through their website at www.csib.ca.gov (search: "complaint form"), by telephone at 800-321-CSLB (2752), or by writing to P.O. Box 26000, Sacramento, CA 95826. If the attached contract was not negotiated at the contractor's place of business, you have a Three -Day Right to Cancel the contract, pursuant to Business and Professions Code (BPC) section 7159, as noted below. For further details on canceling the contract, see the Notice of Cancellation, which must be included in your contract. Three -Day Right to Cancel You, the buyer, have the right to cancel this contract within three business days. You may cancel by e-mailing, mailing, faxing, or delivering a written notice to the contractor at the contractor's place of business by midnight of the third business day after you received a signed and dated copy of the contract that includes this notice. Include your name, your address, and the date you received the signed copy of the contract and this notice. This document was developed through coordination of the California Contractors State License Board and the California Public Utilities Commission pursuant to Business and Professions Code section 7169. 13L-6 (05/2018) DocuSign Envelope ID: DEE4FA2B-ED16-4C48-9719-9E29CCD269EC 3855 Atherton Road Rocklin, CA 95765 P: 1.888.244.2513 F: 1.888.244.2514 Customer Name: Jeff Deneau energy Date: 6/1/2019 CA License #998627 Phone: 9095411155 Address: 52290 Avenida Vallejo City: La Quinta State: CA Zip: 92253^ Email: eneau. je-r-rlrai I.Com TERMS We hereby propose to furnish the materials and perform the labor necessary for the completion of the Solar System. All material is guaranteed to substantial workman like manner. SYSTEM AND FINANCING DETAILS System Size 4.27 kW Contract Price $ 17500 CASH ❑ PACE Funding ❑ Loan Pal OCAFirst ❑ Sunlight HERO ❑ SALAL ❑Mpower ❑ Other Panel Brand and Model #: LR6-60PB-305M Inverter Brand and Model #: Sol ar Edge SE3000 Detailed ADD-ONS: Please retain quote from Infinity Energy prior to contract signing ❑ Critter Guard $ _ ❑ Re-Ro Ofi3rd party quote neededfrom a licensed roofer/ $_ ❑ MPU $_ Down Payment $ 0 Add-Ons ❑ 25 year Extended Warranty ❑ O&M 0 Battery Storage Quantity: 14 Quantity: INFINITY HOME ADD-ONS: ❑ Solar Plus (see additional contract) ❑ Infinity Home(see additional contract) ❑ Ground Mount $ - DoeuSiyned by: Sales Person:» Pequeno HIS License #: 106097 SP Signature: Notice To Homeowner You are entitled to a completely filled in copy of this Contract, signed by both you and the Contractor, before any work may be started. Further, the Notice of Cancellation contained below may be sent to the Contractor at: 3855 Atherton Road, Rocklin, CA 95765 (§7159(3)(A) California Contractors License Law). Pavment Details Down Payment The down payment may not exceed $1,000.00 or 10% of the contract price, whichever is less. Down Payment: A down payment of $ 0.00 shall be payable on or before 6/1/2019 Contract Price: The total Contract Price shall be $ 17500 Schedule of Progress Payments The balance of the Contract Price shall be paid as follows (Only applicable for cash purchases): $ (50%) @ the completion of permitting; $ (50%) @ the completion of final permit (signed by the local AHJ/Building Department) (The schedule of progress payments must specifically describe each phase of work, including the type and amount of work or services scheduled to be supplied in each phase along with the amount of each proposed progress payment. IT 1S AGAINST THE LA W FOR A CONTRACTOR TO COLLECT PAYMENT FOR WORK NOT YET COMPLETED, OR FOR MATERIALS NOT YET DELIVERED. HOWEVER, A CONTRACTOR MAY REQUIRE A DOWN PAYMENT.) DocuSign Envelope ID: DEE4FA2B-ED16-4C48-9719-9E29CCD269EC Please Initial: If the homeowner is not available for the inspection and it does NOT occur, final payment is due within 5 days of installation completion. Only applicable for cash purchases E LL,.' Extra work and Change Orders become part of the contract once the order is prepared in writing and signed by the parties prior to the commencement of any work covered by the new change order. The order must describe the scope of the extra work or change, the c to be added or subtracted from the contract, and the affect the order will have on the schedule of progress payments. L f Financing options: Customer agrees to comply with requirements set forth by the financing company, in order to complete payment to Infinity Energy. Financing milestones vary depending on the financial institution. Direct all specifications to the agreed upon financing option above. Late Payments: In the event that the undersigned fails to make the final payment when due, a late fee of $250.00 shall be assessed and the balance shall accrue interest at a rate equal to the lesser of 1% per month or the highest rate allowed by applicable law. Only applicable for cash purchases. Releases: Upon satisfactory payment for any portion of the work performed, the Contractor, prior to any further payment being made, shall furnish to you a full and unconditional release from any potential lien claim authorized pursuant to sections 8400 and 8404 of the Civil Code for that portion of the work for which payment has been made. Payments to be made by check or money order to: Infinity Energy Credit Check Authorization In compliance with the Fair Credit Reporting Act (FCRA), customer is authorizing Infinity Energy, to obtain a consumer credit report. Customer should refer to the FCRA for further explanations of Customer's Rights. Authorization only applies if signature and date appears within this segment of the provided contract. Signature: Signature: C ,..S:c.. F,., Date: 6/1/2019 Date: Performance by Contractor Contractor's performance shall be based upon the following terms and conditions: Approximate Start Date: Contractor shall exercise best efforts to commence improvement work on or about: 60 days after contract signing - upon the approval of Permit by the local AHJ Approximate Completion Date: Work should be completed in approximately 90 business days after commencement Concluding Provisions: Further Assurances - Each Party shall, from time to time, upon the request of the other Party, execute and deliver any instruments or documents, or undertake any acts, reasonably necessary to implement or carry out the intent of this contract. Entire Agreement - This Contract constitutes the entire agreement between the Parties pertaining to the subject matter contained herein and supersedes all prior and contemporaneous agreements, representations, and understandings of the Parties. No supplement, modification, or amendment of this Contract shall be binding unless executed in writing by both Parties. No waiver of any of the provisions of this Contract shall be deemed, or shall constitute, a waiver of any other provision, whether or not similar, nor shall any waiver constitue a continuing waiver. No waiver shall be binding unless executed in writing by the Party making the waiver. Attorneys' Fees - In the event legal action is necessary to defend, enforce or interpret any of the provisions of this Contract, the prevailing party shall be entitled to recover all costs and resonable attorneys' fees incurred in connection therewith. Severability - If any provision of this Contract is held invalid or unenforceable by any court of appropriate jurisdiction, it is the intent of the Parties that all other provisions of this Contract be construed to remain fully valid, enforceable, and binding on the Parties. Acceptance of Proposal The above prices, specification and conditions are satisfactory and are hereby accepted. You are authorized to complete work as specified. Payment will be made as outlined above. This proposal may be withdrawn by Infinity Energy if not accepted within 30 days of proposal date. Signature:�ilf' Date: 6/1/2019 2,4 !GlpNF2. Signature: Date: DocuSign Envelope ID: DEE4FA2B-ED16-4C48-9719-9E29CCD269EC Notices and Additional Provisions A. Warranties: Solar Panels, Inverters, and batteries have a manufacturer's warranty against defects and undue degradation of electrical generation output. The undersigned acknowledges that such warranty has been provided by the manufacturer and not by Infinity Energy. This warranty may comply with the California Public Utility Code §2854(d)(4). Infinity Energy's only ongoing warranty obligation is for any failure to install the solar system in conformance with the manufacturer's specifications and in compliance with all applicable electrical and building code standards. B. Note about Extra Work and Change Orders: Extra work and change orders become part of the Contract once the order is prepared in writing and signed by the parties prior to the commencement of work covered by the new change order. The order must describe the scope of the extra work or change, the cost to be added to or subtracted from the Contract, and the effect the order will have on the schedule or progress payments. C. Liability Insurance: A notice concerning commercial general liability insurance is attached to this Contract. D. Workers' Compensation Insurance: A notice concerning workers' compensation insurance is attached to this Contract. E. Mechanics' Lien Warning: Anyone who helps improve your property, but who is not paid, may record what is called a mechanics lien on your property. A mechanics lien is a claim, like a mortgage or home equity loan, made against your property and recorded with the county recorder. Even if you pay your Contractor in full, unpaid subcontractors, suppliers, and laborers who helped to improve your property may record mechanics liens and sue you in court to foreclose the lien. If a court finds the lien is valid, you could be forced to pay twice or have a court officer sell your home to pay the lien. Liens can also affect your credit. To preserve their right to record a lien, each subcontractor and material supplier must provide you with a document called a 'Preliminary Notice.' This notice is not a lien. The purpose of the notice is to let you know that the person who sends you the notice has the right to record a lien on your property if he or she is not paid. BE CAREFUL. The Preliminary Notice can be sent up to 20 days after the subcontractor starts work or the supplier provides material. This can be a big problem if you pay your Contractor before you have received the Preliminary Notices. You will not get Preliminary Notices from your prime Contractor or from laborers who work on your project. The law assumes that you already know they are improving your property. PROTECT YOURSELF FROM LIENS. You can protect yourself from liens by getting a list from your contractor of all the subcontractors and material suppliers that work on your project. Find out from your Contractor when these subcontractors sta rted work and when these suppliers delivered goods or materials. Then wait 20 days, paying attention to the Preliminary Notices you receive. PAY WITH JOINT CHECKS. One way to protect yourself is to pay with a joint check. When your Contractor tells you it is time to pay for the work of a subcontractor or supplier who has provided you with a Preliminary Notice, write a joint check payable to both the Contractor and the subcontractor or material supplier. For other ways to prevent liens, visit CSLB's Internet Web site at www.csib.ca.gov or call CSLB at 800-321-CSLB (2752). REMEMBER, IF YOU DO NOTHING, YOU RISK HAVING A LIEN PLACED ON YOUR HOME. This can mean that you may have to pay twice, or face the forced sale of your home to pay what you owe. F. Information about the Contractor's State License Board (CSLB): CSLB is the state consumer protection agency that licenses and regulates construction contractors. Contact CSLB for information about the licensed contractor you are considering, including information about disclosable complaints, disciplinary actions, and civil judgments that are reported to CSLB. Use only licensed contractors. If you file a complaint against a licensed contractor within he legal deadline (usually four years), CSLB has authority to investigate the complaint. If you use an unlicensed contractor, CSLB may not be able to help you resolve your complaint. Your only remedy may be in civil court, and you may be liable for damages arising out of any injuries to the unlicensed contractor or the unlicensed contractor's employees. For more information: Visit CSLB's Internet Web site at www.csib.ca,gov Call CSLB at 800-321-CSLB (2752) Write CSLB at P.O. Box 26000, Sacramento, CA 95826 DocuSign Envelope ID: DEE4FA2B-ED16-4C48-9719-9E29CCD269EC COMMERCIAL GENERAL LIABILITY INSURANCE 19GLI Infinity Energy nc [licensed contractor] carries commercial general liability insurance written by Admiral Insurance Company [insurance company]. You may call the insurance company at 916-960-1400 to check the contractor's insurance coverage. WORKERS' COMPENSATION INSURANCE Infinity Energy Inc [licensed contractor] carries workers compensation insurance for all employees. DocuSign Envelope ID: DEE4FA2B-ED16-4C48-9719-9E29CCD269EC NOTICE OF CANCELLATION Date of Transaction: You may cancel this transaction, without any penalty or obligation, within three business days from the above date. If you cancel, any property traded in, any payments made by you under the contract or sale, and any negotiable instrument executed by you will be returned within 10 days following receipt by Contractor of your cancellation notice, and any security interest arising out of the transaction will be canceled. If you cancel, you must make available to the Contractor at your residence, in substantially as good condition as when received, any goods delivered to you under this contract or sale, or you may, if you wish, comply with the instructions of the Contractor regarding the return shipment of the goods at the Contractor's expense and risk. If you do make the goods available to the Contractor and the Contractor does not pick them up within 20 days of the date of your notice of cancellation, you may retain or dispose of the goods without any further obligation. If you fail to make the goods available to the Contractor, or if you agree to return the goods to the Contractor and fail to do so, then you remain liable for performance of all obligations under the contract. To cancel this transaction, mail or deliver a signed and dated copy of this cancellation notice, or any other written notice, or send a telegram to: , (name of seller) at (address of Contractor's place of business) not later than midnight of [Date]. I hereby cancel this transaction. [Date], (Buyer's signature). I, , hereby acknowledge receipt of this Notice of Cancellation this _ day of ,20 [Name] DocuSign Envelope ID: DEE4FA2B-ED16-4C48-9719-9E29CCD269EC NOTICE OF CANCELLATION Date of Transaction: You may cancel this transaction, without any penalty or obligation, within three business days from the above date. If you cancel, any property traded in, any payments made by you under the contract or sale, and any negotiable instrument executed by you will be returned within 10 days following receipt by Contractor of your cancellation notice, and any security interest arising out of the transaction will be canceled. If you cancel, you must make available to the Contractor at your residence, in substantially as good condition as when received, any goods delivered to you under this contract or sale, or you may, if you wish, comply with the instructions of the Contractor regarding the return shipment of the goods at the Contractor's expense and risk. If you do make the goods available to the Contractor and the Contractor does not pick them up within 20 days of the date of your notice of cancellation, you may retain or dispose of the goods without any further obligation. If you fail to make the goods available to the Contractor, or if you agree to return the goods to the Contractor and fail to do so, then you remain liable for performance of all obligations under the contract. To cancel this transaction, mail or deliver a signed and dated copy of this cancellation notice, or any other written notice, or send a telegram to: , (name of seller) at Contractor's place of business) not later than midnight of (address of [Date]. I hereby cancel this transaction. [Date], (Buyer's signature). I, hereby acknowledge receipt of this Notice of Cancellation this _ day of , 20 _ [name] (888) 244.2513 energy golnfinkyenergy.com To whom It may concern, All Corrections for 52290 Avenida Vallejo have been addressed. 1. On page 4 the single Line the system will be Continuously Grounded. 2. Wires will be ran Inside conduit. Bry - n 1530) 870.6446 1 Owner Infinity Energy Inc. 1J energy Lie # 998627 w C o car K � co o � U " w C 0 2to 4& Qaiata ofrlm DESERl' PERMITGEM PLAN LOCATION: Project Address: q ,� Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: V0.11 ``� o q,Z7 kwDC-, . Applicant Name: �cxv�"ei 1Jctv�'S Address: a r 4 City, ST, Zip: CaI-2.Z71 Telephone: Ct 5 a 39 — a foil Z- Email:�ar�e_ O �� r�� en er r LL rn Valuation of Projects_ /7, .D B0 Contractor Name: New SFD Construction: Address: 7a3'S �r l Conditioned Space SF City, St, Zips 1L'2 Garage SF Telephone: o23�T , Patio/Porch SF Email: �, C u Fire Sprinklers SF State Lic: &32 City Bus Lic: Arch/Eng Name: Construction Type: Occupancy: Address: Grading: City, St, Zip Telephone: Bedrooms: Stories: # Units: Email: State Lic: City Bus Lic: Property Owner's Name: r New Commercial / Tenant Improvements: Address: a aq 0 Jf— Total Building SF City, ST, Zip v Apr of Z 2 53 Construction Type: Occupancy: Telephone: Email: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 Complete 5Vttibm and Product Certifiretions Po§ltivfi povuer toleirante (0 -+5W) guaranteed IEC 61215, IEC61730, uL1703 ISO 9001:2008: d0 Quality Management System High rtiodule tonvir3ion efficiency (up to 18.7%) ISO 14001: 2004: ISO Environment Management System SIbWer powtir degradation enabled by Low LID Mono PERC technology: first year �2%; T562941i Guideline for module design qualification and type approval 0.5501: Year 2-25 OHSAS 18001: 2007 Occupational Health and Safety better energy yield with excellent low irradiance performance and temperature coefficient n7t��l Solid PII) resistance ensured by solar cell process optimizal:on and careful module BObt $r selection • Specifications subject to technical changes and tests LONGi Solar Adaptable to harsh environment: passed rigorous salt mist and ammonia tests reserves the right of interpretation RObu3t frame (40mm) withstands mechanical loading of 540OPa for snow load on front and 2400Pa for wind load on rear side ■ �� Solar Roam 6-2 Building 8, Sand: +Plaza, Lane 377 Z E-mail:gzhi Road, Pudoic Distract, Shanghai, 201203 Tacebock: wviv/.faceboo1k.com/LONGi Farom/L 21-61047377 rc�zil: module@longi-silicon.com Faceboalc w�rrvi.facebook.com/LONGi Solar Note: Due to continuous technical innovation, R&D and improvement, technical data above mentioned may be of modification accordingly. LONG Solar have the sole right to make such modification at anytime without further notice; Demanding party shall request for the latest datasheet for such as contract need, and make it a consisting and binding part of lawful documentation duly signed by both parties. 20180401 Unitr:mm Tolerance: both. t}mm W di tlmm IkNhc tlmm PldH_tlmm t—'.-�-•_---- it LR6-60PB 285~305M Cell Orientation:60 (6x10) Junction Box: IP67, three diodes Output Cable: 4mm', 1000mm in length Connector: MC4 or MC4 comparable Weight: 18.2kg Dimension: 1650x991x40m m Packaging: 26pcs per pallet Model Number Testing Condition Ma lfYium Power (12if l'tw) STC : NOCT 286 209,E LRt"a=60Pi1=290M STC NOCT 290 213.2 LR6=60PS-295M STC NtOCt a96 216,$ Open Circuit Voltage (VOe/V) 39.5 3fi 39:7 36.7 39.9 36,9 Short Clttuit CNf flit (10A) 9Ad 7.a2 96111 1:72 169 7191 Voltage at Maxithufn Power (VMPM 32.1 29,5 32.3 29.7 32:5 29,9 Clafr@ML at MAXII'llom Pow@f (ftlp/A) aaa : T10 11.96 1.1tt 9105 1114 Module Efficiency(%) T 17.4 17.7 18A STC (Stand@rd Toting Conditions): Iitd€iW)CO 100OW/tii/l C@II f@n1p0fetur@ A C; Sp@UM at AM1 5 Operational Temperature: -40 C -+85 C Power Output Tolerance: 0"+5 W Maximum System Voltage: DC1000V (IEC) Maximum Series Fuse Rating: 20A Nominal Operating Cell Temperature:45±2 C Application Class: Class A LR6-OO158-900M L-R6=6OPB-305M STC NOCT STC NOa 300 40:1 220,E 37:1 a06 y 40.2 224,2 3712 9.a l 1:91 944 8,01 32:8 - 30:1 33:0 36A 9 1 122 9124 1139 1a:3 AJ NOCT (Namlhal Operating Cell fi?rfipera _uee): Irr6dience a00W/rill; Afrlbient Temperature 20 >, Spectra m AM1.5, VVlhd at lfn/S librbperatur@ Cbeilh 2fit Of itt Unripareture tbAtieht fat Vat 7ampbratUtt ta(affitient bf PfhaR Current -Voltage turve Juit OP®-R®0M) 12 Celloanp-2VC 10 xcavhe' a -- S nwn.r - c Voltage M N 4-6.057VC Trent Side Illlalrltnutn Static LbMirij ;0-2,36%1 C Rear We Makithtjtb ttatic L"ding '0 Now C Fiail3tone Uit PoWer-Voltage Cutve (LR6-6006-300M) 350 CcllteM,Z.0 300 — teomv/a' — adgw/+rc —iugw/m� 250 ""a aooW/m 200 150 100 50 - 0 �~ 0 10 20 30 40 Voltage M 5400150 3496pa 2Srilfh Flailst5ne at th@ speed of 221m/s tumnt4oltoge Cum (06-60 6400M) i tiMN/h' ad—cenropm•r�e y —CHTE p-'SL` 4 — Cell TOT-45'C V r Cen Temp-S 'C Z - cen Temp# C — Co Tempd5°C Voltage M Room 201, Building 8, Sand: +Plata, Lane 377 Zmail: od Road, Pudong District, Shanghai, 201203 Tel: +86-21-61047332 Fax:+86-21-61047377 E-mail: module@longi-silicon.com L014GI Solar Facebook: www facebook.com/LONGI Solar Note: Due to continuous technical innovation, R&D and improvement, technical data above mentioned may be of modification accordingly. LONGi Solar have the sole right to make such modification at anytime without further notice; Demanding party shall request for the latest datasheet for such as contract need, and make it a consisting and binding part or lawful documentation duly signed by both parties. 20180401 solar=@@ Single Phase Inverter with HD -wave Technology for North America SE300OH-US / SE380OH-US / SE500OH-US / SE600OH-US / SE760OH-US / SE1000OH-US / SE1140OH-US M oaw"Y- u -JID —, 6 � Y 4 w t Y sblarnTY 0 wiai�an� 4 o ra M 0 ■ www.solaredge.us solar =a@ Single Phase Inverter with HD -Wave Technology for North America SE300OH-US / SE380OH-US / SE500OH-US / SE6000H-US/ SE760OH-US / SE10000H-US / SE1140OH-US SE3000H•USI SE380OH-US I SES000H-US SE6000H-US SE7600H-US SE10000H-US SE1140OH-US OUTPUT Rated AC Power Out 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 VA ........ ......... ............................. ..... I .......... 3300,@ 208V. ................. 5000 @, 2Wy................. ................. ........ .................... Max. AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V7600 10000 11400 VA ................. .. .......... .......... I......3300,@ 208V......... ........ ,5000 @ 208V................. AC Output Voltage .-Nom.-Max. Min ... .............. .............. ... ..... ..... ........................... ....................................................................... J �/ Vac AC Output Voltage Min: Nom.-Max. ........ ....... I ......... ..I ........................ (211; 240 ; 264).......................................................................... J J J ,/ ................. J J J Vac AC Freguenty. Nggo !nal) .... .......................................................................................................................... .......... 5R:3 - 60 - 60.5(4 I ..... ...... I ........ . ............ ..... .... I...... Hz Maximum Cantfnuous Output Current Current 208V - 16 _ 24 - - q ..................................................................................................................... Maximum Continuous Output Current .... ....... ..P240V..... .................... ........ 12.5 ............. 16 4.......4..............I....... 21 25 32 42 47.5 A ' GFDI Threshold I... i .............................. ...................... A .... Utility Monitoring, Islacling•Pratectian, n _. ... .............................. ........................................... .4................ .........., Yes Maximum DC Power @240V ................,.....,.... 50 5400 46...... 7750 4300 11800 15500 17b50 W Maximum DC Power @208V .............................. - 510Q .. ............................. - 7750 ................................. - - - Transformer.less, Ungrounded.................................................................... ...................................°.................................... Yes... Maximum Input Voltage ......................................... 480 I ....... ....... ........ .. Vdc Nominal DC Input Voltage ................ ................. ............ . ............................................................................. 380.....................................................4fl0....., Vdc '.. Maximum Input Current 208V ........... ..............................................?........... ................. _ Maximum Input Current @240V ..... S.S .... ........4.........4.... 10.5 13.5 16,5 20 27 I'............... 30.5 Adc Max, Input Short Circuit Current, ................. ....... ..................... Adc,... Reverse Polarity Protection . .. ............. Yes ......................................... Ground Fault lsolaHon Detection ...... .............I.... ................ 600ka5e......tp .......... ......... Maximum Inverter Efficiency 99 .......... ............. 99.2 CECWelhted ..... ........... ....................... W........ ....... .....................I .............................. Nighttime Power Consum tion . ...... ....... ................. .................... < 2.5 yU ADDITIONAL FEATURES Supported CammuniCatiion InterFaces. .................................................................. R5485, Ethernet, 2i Bee faptivnal), Cellular optional} Revenue Grade Aata qNS! C12.20 ........................ J .......................... Dptiorfal Rapid Shutdown - NEC 2014 and 2017 .............................. .......... ............... STANDARD Safety............... . ........ ........... Grid Connection Standards ...................................... . Emissions Automatic Rapid Shutdown upon AC Grid Disconnect .... Mto U1.17R1r ULA7415A; LA16993t CSAC2?,2r21Canadian co 14 AFCI acrdln6tu,TL, I, ................................. .. IEEE1547, Rule i Rule (HIS ........ .................... FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Canduft SizeE AWG Range 3Lr minimum 14 6 AWG 14 4 AWG DC Input Conduit Size /# of Strings / �4"minimum 3/4" minimum / 1-Z strings / 14-6 AWG 34" minimum j 1-3 strings / AWG Ran e 6.................................................:,.........................................................................1A.6AWG Dimensions with Safety Switch (HxWxD) ...... ..........,.. 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 �540 x 370 in / mm * .............................................................. -it x 5 Wei 4 S Switch g y ................ __ � •� ........................?:..:zl.sia.............25.2i111:.............._.. 38:�.i'17:6......... Ib/kg.. Noise<25 ........................ ...... —,................................................ �50 d8A Cooling ......:............................................................................................................................................... ........,........ ............. .. ...... Natural Convection Natural convection ..,. Operating Temperature Range............ -13 to+140 �_ 25 tv+60t°I 40'F{ 4a'C option] ................................................. Protection Rating ................................... NEMA 3R {Inverter with_Safety Switch} �'� For othormeonal setflngs planse contact solarEdgc vupport i:i Revenue grads invertcrP/N:5£x, 14-Us000NNc2 (3) For power de•rutingtriWmation Wet to: httpsfltviwt.solaredge.cam/sites/default/files/se-temperature-deratine note-na.pdf (41-4o version P/N: SbwftK-USMUNN U4 solar =@" SolarEdge Power optimizer Module Add -On For North America P320 / P370 / P400 / P400 W USA-CANADA- GERMANY ITALY- FRANCE- JAPAN -CHINA - AUSTRALIA -THENEiHERLANDS-UK-ISRAEL-TURKEY -SOUTHAFRICA-BULGARIA-INDIA wWW.Solafedge.US solar=@@SolarEdge Power Optimizer Module Add -On for North America P320 / P370 / P400 / P405 P320 P370 P400 P405 OPTIMIZER MODEL (for high -power (for higher -power (for 72 & 96-cell (for thin film (typical module compatibility) 60-cell modules) 60 and 72-cell modules) modules) modules INPUT Rated Input DC Powers�1 ... ....... ..........1.32€1 370 400 405 ........ Vvf Absolute Maximum Input Voltage 48 60 80 12S Vdc (Voc at lowest temperature) MPPT Operating Range 8 :48 8 - 60 8- 80 12.5 105 .......... ........................... Vdc ................... Maximum Short Circuit Current (Isc) ... 11 10.1 Adc Maximum DC Input Current ............. ...................... 13;75............. ....... ... ..................... 3i 53.................-........ ..... Maximum Efficiency 99.5 Weighted Efficiency...................... ....................._.........................g8 :8.................-................. % ...... Qyer'v' t6 a Cat o 11 OUTPUT DURING OPERATION POWER OPTIMIZER CONNECTED TO OPERATING SOLAR EDGE INVERTER) Maximum Out ut Current p 15 Adc ................ ........ I,_..................................-...ga...,.................:.............,.....:...._..................................... Macdmum Output Voltage 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power 1f 01 Vdc O timlzer STANDARD COMPLIANCE EMC FCC Part15 ss ClaB, IEC61000-6-2, IEC61000-6-3 Safety ..................................... IEC62109-1 (class Il.safetY)...... .................... .......... ....Yes ..... ....... RoHS INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 .....Vdc Compatible inverters All SolarEdge Single Phase and Three Phase Inverters ........................,............ ...........I............................ .......................... ........... Dimensions(WxLxH) ...1......... 128x152x28/5x5.97x1.1 128x152x36/ 12Sx152x50/ S x5,97x1.42 Sx5.97x1.96 mm/in Weight (including cables) ........................ 630 / 1A 750 / 1.7 845 / 1.9 .................. I...I...............-....... gr / )b ... ..............I........... Input Connector ..................... MC4 Compatible MC4/ MC4 Compatible .....1....I.............. Am&Rplo AH4 ............................. .I ... ....... ........ ..... ........... Output Wire Type / Connector Double Insulated; MC4 Double Insulated; MC4/ Double Insulated; MC4 Compatible Compatible Am henolAH4 Output Wire Length 0.95 3.0 1.2 / 3.9 ... ............................. ......:,.... ........................................... Operating Temperature Range ...... ...................................... ...............40.-+85/-40-+185 ........... ........................,... ........... ...... ..... .... -.C��F „ .. Protection Rating IP68 / NEMA6P Relative Humidity .................. ....... •IiI .................. .... ....... ............ .............0.:100...................................................... ...... %,...... leto+5% Rated STC power of the module. Module of up power tolerance allowed. PV SY5TEM DESIGN USING SINGLE PHASE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTERt2jt31 HD -WAVE Minimum String Length P320, P370, P400 R ....................... ................... ......_... 18 10-...-.... (Power Optimizers). P405.......................................... .... .. ........ .............._............ ..........$........ .........1a........... .......... . ..... Maximum String Length 25 25 SDfil (Power Optimizers) ...................... ...-. .......-....... ... :... ....................... ......... .. ... ..... Maximum Power per String .............. .......... 5700 (6000 with I 5250 SE7600H-US�......1.........................I 6000 12750 ........I........I........ ........................ W .....I...... Parallel Strings of Different Lengths Yes or Orientations 12l For detailed string sizing information refer to: http://wwx4solaredge.com/sites/default/files/strinojlzing_na.pdf. 131 It is not allowed to mix P405 with P320/P370/P400/P600/P700/P800 in one string. 0I A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement Snap rack, - Solar Mounting Solutions Series 100 Residential Roof Mount System The SnapNrack Series 100 Roof Mount system is engineered to optimize material use, labor resources and aesthetic appeal. This innovative system simplifies the process of installing solar modules, shortens installation times, and lowers installation costs; maximizing productivity and profits. The series 100 Roof Mount Systern boasts unique, pre -assembled, stainless steel "Snap - In" hardware and watertight flash attachments, This system is installed with a single tool. No cutting or drilling rneans less roll waste; it is fully integroted with built-in wire 11101709er?ient, s011.10011s for ail roof types, ones si e-fits�all features, and can withstand extretne environmental conditions. Series 100 is listed to UL Standard 2703 for rounding/bonding, Fire Clossification ;end. Mechonical Loadinge UL 2703 Certification 011id C0011. liar°rce erlIsLrres that SnapNrack installers >�an cr�rrtiliLle to provide the best ira i lass lostallatlons in clunllty. safety and effic;lelICYn • Appealing design With built-in aesthetics • No grounding lugs required for modules • All banding hardware Is fully Integrated 0 flail splices bond rails together, no rail jumpers required • No drilling of rail or reaching for other tools required i Mass A Fire Rating for Type 1 and 2 modules System Features Include Snap in Single Tool Hardware Installation Easy Leveling No Cutting or Drilling p integrated Wire Preassernbled Integrated bonding UL 2703 Certified Management hardware Resources snapnrack.com/resources Design snapnrack,corn/configurator Where to Buy snapnrack.com/where-to-buy Snap rack - Solar Mounting Solutions Stainless Bolt with Stainless Steel Split -Lock Washer Bolt with Split - Lock Washer F�_ Bonding Adjustable End Clamp Top Bonding Mid Clamp Bonding Adjustable. Bonding End Clamp Boitom Channel Nut Bonding Adjustable Bonding Mid Clamp End Clamp 242-02067 242-02053 Standoff Clamp Assembly Rubber A Rain Collar Mill Finish --�z Standoff Mill Finish Standoff Base (1-Hole Base Shown) - Standoff 242-92057 Materials Material Finish Wind Loads Snow Loads Array Pitch Splice !,A�Bgonding Splice Base Stainless Hardware with Split -Lock Washers Bonding Standard Rail Splice Serrated Stainless _/e Channel Stool Flange Nut Nut Serrated Stainless Steel Flange Bolt 92 Degree L Foot Mill Finish L Foot L Foot Base Flashing L Foot Base with Flashing 242-92050 Standard Rail 015-09816 Bonding Channel Nut Stainless Bolt with Split Lock Washer Ground Lug 242-02101 12-6 A W G Copper Wire Ground Lug Assembly _ COME REQUIRED PER ROW OF MODULES) Channel Nut Stainless Flange Nut Stainless Flange Bolt All Purpose L Foot Metal Roof Base Assembly Metal Roof Base with L Foot 242-02037 Universal End Clamp (UEC) Wave UEC Pull Strap UEC Wedge I_ Stainless Steel Bolt with Flat Washer Universal End Clamp 242-02215 6000 Series aluminum Stainless steel • Galvanized steel and aluminum flashing Silver and black anodized aluminum • Mill finish on select products • Silver or black coated hardware Note; Appearance of mill finish products may vary and change over time. 110 - 190 mph (ASCE 7-10) 0 - 120 psf 0 - 60 degrees 877-732-2860 www.snapnrack.com contact@snapnrack.com @ 2016 by SnapNrack Solar Mounting Solutions All rights reserved FnapNraek.Wes_100-9rwhur"I Junction Box R Installation Manual Part No. 242-01104 Materials Included © (1) SnapNrack Junction Box Body © (1) SnapNrack Junction Box Lid w/Gasket a © (1) 5/16"-18 X 1-1/4" SS HCS Bolt O (1) SnapNrack Channel Nut O © (1) 5/16"-18 X V SS HCS Bolt p (1) 5/16"-18 Self -Retaining Washer Hardware Description Torque Specification (Ilb-ft) Box Channel Nut 5 lb-ft (60 lb -in) Junction Box Lid 3 lb-ft (36 lb -in) Internal Dimensions Technical Specifications 5.5" x 4.5" x 3.2" (inner box area) Material Box: Polycarbonate Gasket: Rubber UL Environmental Rating Type 4X (NEMA 4X) Certifications UL50 Temperature Range -40°F - 185°F (-40°C - 85°C) Compatibility Box Mount: S100 Standard Rail, S200 Ground Rail Internal Mount: Type O DIN Rail - 7.76" 7.01' Required Tools Socket Wrench 0 Torque Wrench 0 1/2" Socket Step -by -Step Instructions 1. Mount the junction box at the edge of the array where the conduit will terminate. Junction box access after installation should not require the removal of more than one module. 2. Tilt bolt and channel nut so one side of channel nut can easily fall into top rail channel. Press junction box until both clips snap into top rail channel. 3. Pull up on the head of the bolt to snap the channel nut into the top rail channel. Torque mount bolt to 5 lb-ft (60 lb -in). 4. Install outdoor -rated, sealed conduit fitting or sealed strain relief to side wall of junction box and complete wiring installation. CAUTION. Nonmetallic enclosure does not provide grounding between conduit connections. Use grounding bushings and jumper wires. S. Once wiring is complete, close lid and tighten bolt until the front lid tab makes contact with the tab on the box, then torque to 3 lb-ft (36 lb -in) minimum. Snap rack- www.SnapNrack.com contact@SnapNrack.com (877) 732-2860 r� DESCRIPTION: SNAPNRACK, JUNCTION BOX R PART NUMBER(S): 242-01104 DRAWN BY: D. Ryan n _.� REVISION: A SM MARKET$TREET, 29TH F AOR • SAN FIRMCM00, CA 94105 USA FHONf (4195) 580.M - FAX§4151 %0.8902 THEVFORMTION INTHIS WKWWO IS COT¢ '7;TIU� M4 PROPWETA3N. ANY REPRON N. DISCLOSURE OR USE THEREOF 9 PNOWW*p MH FTHE WRITTEN CONSENT OF SUNRUN SOUTH U.C. PARTS LIST ITEM QTY DESCRIPTION 1 1 SNAPNRACK, JUNCTION BOX R. BODY, PLASTIC 2 1 SNAPNRACK, JUNCTION BOX LID; NO GASKET 3 1 SNAPNRACK, JUNCTION BOX GASKET 4 1 SNAPNRACK, RETAINING WASHER FOR STANDARD BOLTS, PLASTIC 5 1 BOLT, FLANGE, 5/16IN-18 X 1IN, NON -SERRATED, BLACK, SS 6 1 SNAPNRACK, ORIGINAL CHANNEL NUT 7 1 BOLT, FLANGE, SERRATED, 5/16IN-18 X 1-1/4IN, BLACK, SS MATERIALS: POLYCARBONATE, STAINLESS STEEL, RUBBER OPTIONS: DESIGN LOAD (LBS): N/A ULTIMATE LOAD (LBS): N/A TORQUE SPECIFICATION: 5 (CHANNEL NUT), 3 (LID) LB -FT CERTIFICATION: UL50, NEMA 4X RATING WEIGHT (LBS): 1.16 DESCRIPTION: SNAPNRACK, JUNCTION BOX R DRAWN BY: D. Ryan sflapHrack- PART NUMBER(S): 242-01104 ALL DIMENSIONS IN INCHES REVISION: A 595 MARKET STREET, 29TH FLOOR - SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 - FAX (415) 580-6902 THEINFORAIATION INTHIS DRAWING IS CONROENTWLAND PROPRIETARY ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED W ITHONTTHE WRITTEN CONSENT OF SUNRUN SOUTH LLC. 4.31 3.05 �— a 2.69 I 4.54 1.28 �1 �J 5.52 DESCRIPTION: DRAWN BY: SNAPNRACK, UNIVERSAL TILE HOOK D.Ryan SnapNruck- REVISION., PART NUMBER(S): A 595 MARKET STREET, 29TH FLOOR - MN FRANCISCO, CA 94105 USA PHONE (415) 580.6900 - FAX (415) 580-6902 232-02044 THE INFORMATION IN THIS DRAWING IS THEREOFIS P OHI PROPRIETARY. TMY HE REPRODUCTION, DISCLOSURE,ORUSETHEREOF IS SOUTH LI.C. WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. PARTS LIST ITEM QTY DESCRIPTION 1 1 SNAPNRACK, UNIVERSAL TILE HOOK BASE 2 1 SNAPNRACK, UNIVERSAL TILE ROOF HOOK ARM, SS 3 2 JSNAPNRACK CHANNEL NUT 5/16IN-18 4 1 2 1 BOLT, FLANGED HEX, 5/16IN-18 X 1-1/4IN, SS MATERIALS: 6000 SERIES ALUMINUM, STAINLESS STEEL OPTIONS: DESIGN LOAD (LBS): 350 UP, 600 DOWN, 250 SIDE ULTIMATE LOAD (LBS): 1024 UP, 635 DOWN, 1250 SIDE TORQUE SPECIFICATION: 12 LB -FT CERTIFICATION: UL 2703, FILE E359313 WEIGHT (LBS): 12.16 DESCRIPTION: DRAWN BY: SNAPNRACK, UNIVERSAL TILE HOOK D.Ryan REVISION: PART NUMBER(S): /� 232-02044 A F 1.25 +---d 4.91 3.59 11 snapWack" 595 MARKET STREET, 29TH FLOOR • SAN FRANCISCO, CA 94105 USA PHONE (415) 560_6900 • FAX (415) 560-6902 THE MFURWFI ION IN THIS 04AVANG IS COPFIOEWT A PRCPR1ETMY. My REPAOOYCMN, DISCLOSLOW OR USE THMEOF 1$ P"lNFFEO W MJOL T THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. ALL DIMENSIONS IN INCHES DESCRIPTION: - - DRAWN BY: SNAPNRACK, FLASHED L FOOT PART NUMBER(S): - - - - - 242-92047, 242-92048, 242-92050, 242-92051 v 3 1.1 M.Watkins .5 apIm ack- REVISION: A 595 MARKET STREET. 29TH FLOOR • SAN FRANCISCO. CA 94105 USA DHOW (A 15) 590-0900 . FAX 0IS} SO04902 n� ovw�wmrl w nos annwwvq so wunoexnu Iwo ortwro><avrr. Af1r pSsllmuclKw, ouaaeu�aw ue¢n��ormNnof�rtowrnaur iec _ _ _ _ �NIfC[CH CLHC¢HTM 6WMiAlSGlfH 4G 2 PARTS LIST ITEM QTY DESCRIPTION 1 1 SNAPNRACK, L FOOT BASE, MILL 2 1 SNAPNRACK, L FOOT FLASHING, 12IN X 12IN, BLACK GALV 3 1 SNAPNRACK L FOOT, COMPOSITION 92DEG, CLEAR / BLACK 4 1 NUT, FLANGE, SERRATED, 5/16IN-18, SS 5 1 SNAPNRACK CHANNEL NUT 5/16IN-18 6 1 BOLT, FLANGED HEX, 5/16IN-18 X 1-1/4IKl N, SS MATERIALS: 6000 SERIES ALUMINUM, STAINLESS STEEL OPTIONS: DESIGN LOAD (LBS): 500 UP, 400 DOWN, 300 SIDE ULTIMATE LOAD (LBS): 928 UP, 839 DOWN, 754 SIDE CLEAR BLACK ANODIZED TORQUE SPECIFICATION: 10+ LB -FT GALV STEEL /ALUM FLASHING CERTIFICATION: UL 2703, FILE E359313 WEIGHT (LBS): 0.90 - 1.25 SS BONDING PIP "SSEMBLY MODULE FRAME RAIL NOTE: 1. ADJUSTABLE END CLAMPS USE SAME BONDING PIN DESIGN TO BOND MODULES TO RAIL 6-12 AWG BARE 5116"-18 SS BOLT COPPER WIRE SS SPLIT LOCK WASHER - — (TORQUE TO 16 FT-LBS) / SNAPNRACK GROUND LUG f CHANNELNUT RAIL SS BONDING PINS NOTE: 1. ALL HARDWARE IS INCLUDED FROM MANUFACTURER 2. A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY CONTINUOUS ROW OF MODULES 3. GROUND LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL ASSEMBLER: 4. GROUND LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL OR PERPENDICULAR TO RAIL 5. ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER WIRE INSPECTOR: DESCRIPTION: DRAWN BY: MIKE WATKINS SNAPNRAOK MOUNTING SYSTEM APPROVED BY: CODY NORMAN s �����[���'" REVISION: GROUNDING DETAILS G 1/11/2016 NEW ITEM Solar ��Ia�nilncg Solutions Sunrun South LLC _ 595 MARKET STREET, 29TH FLOOR, a SAN FRANCISCO, CA 94105 USA PART NUMBER: SCALE: PHONE (415)560-6900• FAX(415) 5004902 DNS — THE INFORMATION IN THIS DRAMIG IS CONFIDENTIAL AND PROPRIETARY.ANY PEPP.ODUCTION, DISCLOSURE, ORUSETHEREOF IS PP.OHISITED WI T HOUTTIE WRIT TEN CONSENT OF SUHRUN SOUTH LLC. SOLARMOUNT :E� U N I RAC OLM-WO NT defined the standard 'n snlal racking. [cc�tures are designed to get installers Of t! r_r�of faster. Our grounding honr_ling process clinlin�ites CO[), -)If "u-r're andgrourlriinb straps to reduce costs. 3ystrnls can he col-Ifigiired v iti1 st"lntlnrrl or light rail to moot your desibn necl lffinents at the lwlmest cost PUs Ih12. th slJperl01 asttlel.l � pc cl�. l�r� provlrle,S c, s1trcam1111ed clean erlgc for enhanced curb appeal, th no special hracke is regl1ired for Installation. THE NEW FACE OF SOLAR RACKING Superiv Aesthetics Pnkage $ it I i. 'i1r` yy¢ai Y '7 rr {D! i, 6 r'1L ��i {� Y,j��'ii� P-t� ji !rz a'��{ ���� �' gib � j P� # �� � ��•1���4 =S A� 1 ?.. -�.- r .#?Q. ff. __ I►I ,a 1't._�5 :1�' l�i'd1 r�•1' fat' �a J _ 3�;t1 .s, - �� �. System grounding through Enphosemicroinverlersand trunk cables Light Rail is Fully Compatible with all SM Components Featuring Google Map Capabilities within U-Builder SOLARMOUNT OPTIM'ZED COMPONENTS INTEGRATED BONDING & PRE -ASSEMBLED PARTS Components are pre assembled and optimized to reduce inslallalion slep,; and save labor time. Our new grounding & banding process efrminaIes copper wire and grounding strap; or bonding jumpers to reduce costs I Itilize the microinverter mount svilh a wife management clip for an easier installation. VERSATILITY ONE PRODUCT - MANY APPLICATIONS Quickly set modules flush to the; roof or at a desired tilt angle. Change module uricntahon to portrait or landscape while securing a large varmhy of framed modules on flat, low slope or steep pitched routs. Available in mill. clear and dark anodized finishes to outperform your projects financial and aesthetic aspirations. AUTOMATED DESIGN TOOL DESIGN PLATFORM AT YOUR SERVICE Creating a hill of materials is just a fey! clicks away with U-Builder. a por!erful online tool that streamlines the process of designing a code compliant solar moun lmg system. Save time by creating a user profile, and recall preferences and projects automatically when you fog in. Von will enjoy the ability to share projects with customers: there's no need to print results and send to a distributor, just click and share. 9 LU o 0lulillllI; t)itic UL2703 MICHRACA110ADiNG � SYSTEM flRE CI.cRQUNAS,S�ICAIION 0 sewn UNIRAC INTEGRATED BONDING SPLICE BAR INTEGRATED BONDING MICROINVERTER MOUNT w/ WIRE MANAGEMENT INTEGRATED BONDING MIDCLAMP INTEGRATED BONDING L-FOOT w/ T-BOLT UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT UNMATCHED CERTIFIED ENGINEERING BANKABLE DESIGN PERMIT EXPERIENCE QUALITY EXCELLENCE WARRANTY TOOLS DOCUMENTATION TECHNICAL SUPPORT Unirac's technical support team is dedicated to answering questions & addressing issues in real time. An online library of documents including engineering reports, stamped letters and technical data sheets greatly simplifies your permitting and project planning process. CERTIFIED QUALITY PROVIDER Unirac is the only PV mounting vendor with ISO certifications for 9001:2015, 14001:2015 and OHSAS 18001:2007 which means we deliver the highest standards for fit, form, and function. These certifications demonstrate our excellence and commitment to first class business practices BANKABLE WARRANTY Don't leave your project to chance. Unirac has the financial strength In back our products and reduce your risk. [lave peace of mind knowing you are receiving products of exceptional quality. SOLARMOUNT is covered -by a twenty five (25) year limited product warranty and a five (5) year limited finish warranty. PROTECT YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN PU6201702?i PR6NT[D 2-Piece Standoff Technical Datasheet Pub 101026-1td V1.0 October 2010 2-Piece Aluminum Standoffs .................................... . ............. 1 2-Piece Aluminum Standoff with SolarMount-I 1-flange connection .................... 2 2-Piece Aluminum Standoff with L-foot connection ................................. 2 Standoffs 2-Piece Aluminum Standoffs Part No. 310503, 310504, 310506, 310507, 310553, 310554, 310556, 310557, 310603, 3,10604, 310606, 310607, 310653, 310654, 310656, 310657 A1IN 1 - ____ 3.75 I 00.30 7:5n d Dimensions specified in inches unless noted Standoff and Base Material: • One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38 ksi; Yeild: 35 ksi • Clear or Dark anodized Weight: • 3" Standoff (as shown): 0.522 pounds (237 g) • Add 0.086 pounds per inch (39 g/ inch) Allowable and design loads are valid for a Unirac 2-piece aluminum standoff Attach with zinc plated carbon steel or stainless steel fasteners Resistance and safety factors are determined according to Part 1A section 9 of the 2005 Aluminum Design Manual NOTE: Loads are given for the standoff only. Check load limits for lag screw or other attachment method. Average Ultimate Allowable Safety Design Resistance Applied Load Load Load Factor, Load Factor, Direction Ibs (N) Ibs (N) W Ibs (N) F Tension/ Compression, (4528) (4844) 3.00 1633 (7264) 0.500 Y± UZ Bending, 559 ft Ibs 250 ft Ibs 378 ft Ibs Applied (758 Nm) (339 Nm) 224 (512 Nm) 0.676 Moment* *Example: If the module is mounted 6" (0.5 ft) from the base of the standoff, the allowable side load is 250 ft*lbs/ 0.5 ft = 500 Ibs : �UN!RAC 2-Piece Aluminum Standoff with SolarMount-I 1-flange connection Part No. 05013C, 05014C, 05016C, 05017C Reference the SolarMount-I series datasheet for 1-flange connection specifications. For the 1-flange connection to standoff: • Use included 1 3/" EPDM washer between the 1-flange connection and standoff • Assemble with included 300 series stainless steel %"-16 flanged hex head screw X Use anti -seize and tighten to 30 ft-Ibs of torque Allowable and design loads are valid when components are assembled according to authorized Unirac documents. 1-Flange connections are compatible with SolarMount-I series beams. Resistance factors and allowable loads are determined according to part 1A section 9 of the 2005 Aluminum Design Manual. NOTE: Loads are for the connection and standoff only. Check load limits for the lag screw or other attachment method. Applied Load Direction Average Ultimate Ibs (N) 1415 (6294) Allowable Load Ibs (N) 635 (2825) Safety Factor, FS 2.23 Design Loads Ibs (N) 960 (4270) Resistance Factor, (1) 0.679 Tension, Y+ Compression, Y- 1949 (8670) 873 (3883) 2.23 1320 (5872) 0.677 Transverse, X-, downhill 635 (2825) 313 (1392) 2.03 473 (2104) 0.745 Transverse, X+, uphill 42 (187) 20 (89) 2.15 30 (133) 0.705 OZ Bending, Applied Moment 559 ft Ibs (758 Nm) 250 ft Ibs (339 Nm) 2.24 378 ft Ibs (512 Nm) 0.676 2-Piece AluminUrn Standoff with 1-foot connection Reference the SolarMount datasheet for L-foot specifications. For the L- foot to standoff connection: • Use included 1 1/4" EPDM washer between the L-foot and standoff • Assemble with included 300 series stainless steel W-16 flanged hex head screw • Use anti -seize and tighten to 30 ft-Ibs of torque Allowable and design loads are valid when components are assembled according to authorized Unirac documents. L-feet are compatible with SolarMount, SolarMount Heavy Duty, and SunFrame rails. Resistance factors and allowable loads are determined according to part 1A section 9 of the 2005 Aluminum Design Manual. NOTE: Loads are for the connection and standoff only. Check load limits for the lag screw or other attachment method. Applied Load Direction Average Ultimate Ibs (N) Allowable Load Ibs (N) Safety Factor, FS Design Loads Ibs (N) Resistance Factor, 0 Tension, Y+ 1859 (8269) 707 (3144) 2.63 1069 (4755) 0.575 Compression, Y- 3258 (14492) 1325 (5893) 2.46 2004 (8913) 0.615 Sliding, Z± 1766 (7856) 755 (3356) 2.341 1141 (5077) 0.646 Transverse, X± 486 (2162) 213 (949) 2.28 323 (1436) 0.664 UZ Bending, Applied Moment 559 ft Ibs (758 Nm) 250 ft Ibs (339 Nm) 2.24 378 ft Ibs (512 Nm) 0.676 J" BOLT LOCATION g" BOLT LOCATION ::�UNlRAC 1411 BROADWAY BLVD NE ALBUQUERQUE, NM 87102 USA WWW.UNIRAC.COM PRODUCT LINE: SOLARMOUNT DRAWING TYPE: PART DETAIL DESCRIPTION: RAIL REVISION DATE: October 2016 Standard Rail Lengths: 132" 168" 208" 240" DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL O a PRODUCT PROTECTED BY ONE OR MORE US PATENTS. LEGAL NOTICE SHEET Y4" BOLT LOCATION --\ %" BOLT LOCATION as U IV I RAC 1411 BROADWAY BLVD NE ALBUQUERQUE, NNI 87102 USA WWW.UNIRAC.COM PRODUCT LINE: SOLARMOUNT PART DETAIL DRAWING TYPE: DESCRIPTION: LIGHT RAIL REVISION DATE: October 2016 Standard Rail Lengths: 168" 240" DRAWING NOT TO SCALE Cq ALL DIMENSIONS ARE NOMINAL 0�1 FBI st ^ PRODUCT PROTECTED BY ONE OR MORE US PATENTS LEGAL NOTICE SHEET 01 X4" BOLT LOCATION n BOTTOM CLIP SLOT 3" 3/sBOLT LOCATION 17„ 8 Standard Rail Lengths: 144" 168" 204" 240" U N 1 RAC 1411 BROADWAY BLVD NE ALBUQUERQUE, NM 87102 USA WWW.UNIRAC.COM PRODUCT LINE: DRAWING TYPE: SOLARMOUNT PART DETAIL DESCRIPTION: HD RAIL REVISION DATE: October 2016 DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL M a PRODUCT PROTECTED BY ONE OR MORE US PATENTS LEGAL NOTICE SHEET B CLAMP 30mm to 32mm Module Thickness (1.18" to 1.26") 216 E CLAMP 50mm to 51mm Module Thickness (1.97" to 2.00") WUNIRAC 1411 BROADWAY BLVD NE ALBUOUEROUE, NM 87102 USA WWW.UN IRAC.COM 116 C CLAMP 33mm to 36mm Module Thickness (1.30" to 1.42") F CLAMP 45mm to 47mm Module Thickness (1,77" to 1.85") T 19. 1 32 D CLAMP 38mm to 40mm Module Thickness (1.50" to 1.57") T-1 15. 8 K CLAMP 39mm to 41mm Module Thickness (1.54" to 1.61") 11„ z 3 „ 1„O 16 4 TYPICAL END CLAMP DETAILS PRODUCT LINE: DRAWING TYPE: SOLARMOUNT PART DESCRIPTION: END CLAMPS REVISION DATE: FMAY016 DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL O a PRODUCT PROTECTED BY ONE OR MORE US PATENTS LEGAL NOTICE SHEET xPUNIRAC 1411 BROADWAY BLVD NE ALBUQUERQUE, NM 87102 USA WWW.UNIRAC.COM SOLARMOUNT PRODUCT LINE: DRAWING NOT TO SCALE k ALL DIMENSIONS ARE NOMINAL u1 DRAWING TYPE: PARTS DETAIL a DESCRIPTION: END CAPS PRODUCT PROTECTED BY ONE OR MORE US PATENTS LA REVISION DATE: MAY 2016 LEGAL NOTICE SHEET BONDING SPLICE BAR 0 0 O O I� 4 HIL A 4 JLLr UKILLINto J> >LKtVVJ IINLLUULU TYPICAL SPLICE BAR DETAIL TYPICAL EXPANSION JOINT DETAIL L J\.I.L YY'IN TT. THE SPLICE BAR DOES NOT BOND ACROSS AN EXPANSION JOINT. K ::�UNIRAC 1411 BROADWAY BLVD NE ALBUQUERQUE, NM 87102 USA WWW.UNIRAC.COM PRODUCT LINE: SOLARMOUNT DRAWING TYPE: PART & ASSEMBLY DESCRIPTION: BONDING SPLICE BAR REVISION DATE: APRIL 2016 DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL r—I 0 Q PRODUCT PROTECTED BY ONE OR MORE CCi G US PATENTS Ln SHEET LEGAL NOTICE SOLARMOUNT LIGHT ON L-FOOT MINIMUM HEIGHT 216 i SOLARMOUNT STANDARD ON L-FOOT T MINIMUM HEIGHT 3 5 16 SOLARMOUNT HD ON L-FOOT T MINIMUM HEIGHT 316 D = 1-16 06 x 1 T BOLT FLANGE NUT L FOOT MAXIMUM HEIGHT 316/ 1 MAXIMUM HEIGHT 42" MAXIMUM HEIGHT �1, NOTE: L-FOOT CAN BE INSTALLED IN TWO ORIENTATIONS. PLEASE REFER TO INSTRUCTIONS IN THE QUICK START GUIDE. do: UNIRAC 1411 BROADWAY BLVD NE ALBUQUERQUE, NM 87102 USA WWW.UNIRAC.COM PRODUCT LINE: SOLARMOUNT DRAWING TYPE: PART & ASSEMBLY L-FOOT APRIL 2016 DESCRIPTION: REVISION DATE: DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL rA 0 Q PRODUCT PROTECTED BY ONE OR MORE CC� G US PATENTS Ln SHEET LEGAL NOTICE ::°UNIRAC 1411 BROADWAY BLVD NE ALBUQUERQUE, NM 87102 USA WWW.UN IRAC.COM 4 20 x 4 SS HEX HEAD BOLT a" FLAT WASHER a-20 SS FLANGE NUT PRODUCT LINE: DRAWING TYPE: SOLARMOUNT HD PART & ASSEMBLY DESCRIPTION: BOTTOM CLIP REVISION DATE: APRIL 2016 BOTTOM CLIP DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL M 0 Q PRODUCT PROTECTED BY ONE OR MORE US PATENTS Vi LEGAL NOTICE L SHEET DETAIL A - FRONT L FOOT HINGE do-UNIRAC & 1411 BROADWAY BLVD NE ALBUQUERQUE, NM 87102 USA WWW.UNIRAC.COM DETAIL B - REAR TILT LEG PRODUCT LINE: DRAWING TYPE: SOLARMOUNT ASSEMBLY DESCRIPTION: REVISION DATE: LOW PROFILE TILT APRIL 2016 DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL O Q PRODUCT PROTECTED BY ONE OR MORE US PATENTS LEGAL NOTICE SHEET DETAIL B - REAR TILT LEG DETAIL A - L FOOT dFUNIRAC 1411 BROADWAY BLVD NE ALBUOUERQUE, NM 87102 USA WWW.UNIRAC.COM PRODUCT LINE: DRAWING TYPE: SOLARMOUNT ASSEMBLY DESCRIPTION: HIGH PROFILE TILT REVISION DATE: APRIL 2016 DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL Ln O Q PRODUCT PROTECTED BY ONE OR MORE US PATENTS LEGAL NOTICE SHEET 01 5 18 1 L FEET NOT INCLUDED 16 IN TILT LEG KITS 1" 018' STRUT LENGTHS x 1 1" SS HEX BOLT 9-16 ADJUSTABLE LENGTHS $ x 1 7" x $" HD FENDER WASHER 9-16 STRUT NUT 0 06 x 3" SS HEX BOLT i-16 SS FLANGE NUT 1" &8' SOUARETUBE LENGTHS TILT LEG LENGTHS TOTAL ADJUSTABLE SOUARETUBE STRUT T LENGTHS 8° to 12° 8 s• iaA U N I RAC 1411 BROADWAY BLVD NE ALBUQUERQUE, NM 87102 USA 11� W1Q.U�4161 viviviy 18" to 30" 18" 18" 26" to 44" 26" 26" 40" to 72" 40" 40" 01 PRODUCT LINE: DRAWING TYPE: SOLARMOUNT TILT ASSEMBLY DESCRIPTION: ADJUSTABLE TILT LEG APRIL 2016 REVISION DATE: DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL � O Q PRODUCT PROTECTED BY ONE N OR MORE US PATENTS LEGAL NOTICE SHEET BONDING SM MID CLAMP ::�UNIRAC 1411 BROADWAY BLVD NE ALBUQUERQUE, NM 87102 USA WWW.UNIRAC.COM BONDING SM END CLAMP i 01. 04" t �lz.. 1 116 T VARIES - REFER TO SHEET SM-PO4 PRODUCT LINE: SOLARMOUNT DRAWING TYPE: PART & ASSEMBLY DESCRIPTION: BONDING TOP CLAMPS REVISION DATE: APRIL 2016 DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL O a PRODUCT PROTECTED BY ONE OR MORE US PATENTS LEGAL NOTICE SHEET x UNIRAC 1411 BROADWAY BLVD NE ALBUQUERQUE, NM 87102 USA WWW.UNIRAC.COM 105,, 116„ - 1 THE WIRE MANAGEMENT CLIP IS INSERTED INTO THE SIDE SLOT THEN ROTATED PRODUCT LINE: DRAWING TYPE: DESCRIPTION: REVISION DATE: SOLARMOUNT ASSEMBLY SM WIRE MGMT CLIP APRIL 2016 DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL 00 O Q PRODUCT PROTECTED BY ONE N OR MORE US PATENTS LEGAL NOTICE SHEET A Detail B MID CLAMP TRIM CONNECTION Detail A END CLAMP TRIM CONNECTION 116 316 Ago 1411 BROADWAY BLVD NE ALBUQUERQUE, NM 87102 USA WWW.UNIRAC.COM PRODUCT LINE: I SOLARMOUNT DRAWING TYPE: I ASSEMBLY DESCRIPTION: I SM TRIM REVISION DATE: I MAY 2016 DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL O a PRODUCT PROTECTED BY ONE OR MORE US PATENTS LEGAL NOTICE SHEET DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: S1.00 DESCRIPTION ACCOUNT CITY AMOUNT PV SYSTEM LESS THAN 10KW 101-0000-42403 0 $26.68 DESCRIPTION ACCOUNT CITY AMOUNT PV SYSTEM LESS THAN 10KW PC 101-0000-42600 0 $26.68 Total Paid for ELECTRICAL: $53.36 DESCRIPTION ACCOUNT CITY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $101.40 Total Paid for PERMIT ISSUANCE: $101.40 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $S.00 SHEET INDEX IE-01 TITLE SHEET IE-02 SITE PLAN IE-03 PV MODULE ARRAY LAYOUT IE-04 ELECTRICAL DIAGRAM IE-05 SIGNAGE �SOL Zo 1? - co/ I CITY OF LA 00INT_ A BUILDING DIVISION REVIEWED FOR CODE LIAICE 'LRY DATE APPLICABLE CODES 2016 CALIFORNIA BUILDING CODE (CBC) 2016 CALIFORNIA RESIDENTIAL CODE (CBJ(CGBC) 2016 CALIFORNIA MECHANICAL CODE (CM 2016 CALIFORNIA PLUMBING CODE (CPC) 2016 CALIFORNIA ENERGY CODE (CPC) 2016 CALIFORNIA GREEN BUILDING CODE 2016 LA QUINTA MUNICIPAL CODE SYMBOLS METER INVERTER 1 GROUND •� SWITCH BREAKER FUSE — CONDUIT RUN WIRELESS VICINITY MAP m to 0 Calle Durango Calle Durango Calle Durango d m m _r 3 ry W rb 3 � N e� CI 52290 Avenue Vallejo n h fo _ ID m < N N N ? C m m a w 3 - w n o, m N Ilic+crada Calla Ensenada Calle Ensenada zjj- C-110Fnsensda m A � g SYSTEM INFORMATION SYSTEM SIZE 14.27 kW DC PV MODULES 14 LONGI: LR6-60PB-305M INVERTERS 1 SOLAREDGE INVERTER: SE3000H-US RACKING SNAPNRACK MOUNTING UNIRACK I SCOPE OF WORK I INSTALLATION CONSISTS OF 14 LONGI 305W MODULES, 1 SOLAREDGE STRING INVERTER AND RELATED ELECTRICAL METERING (IF USED) AND SAFETY EQUIPMENT. ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE WARRANTED ALL EQUIPMENT WILL BE INSTALLED AS REQUIRED BY APPLICABLE CODES AND LOCAL UTILITY COMPANY REQUIREMENTS. EXISTING BUILDING INFORMATION I STRUCTURE TYPE: RESIDENTIAL OCCUPIED BUILDING ROOF FRAMING: 2"X8" RAFTERS, 24"OC ROOF TYPE: FOAM CONSTRUCTION NOTES A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CALIFORNIA OSHA REQUIREMENTS Y r v v V V THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY GRID INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES EACH MODULE WILL BE GROUNDED USING THE SUPPLIED GROUNDING POINTS IDENTIFIED BY THE MANUFACTURER. EXPOSED NON -CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENT, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A) REGARDLESS OF VOLTAGE. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED PER SECTION 110 26 CEC ALL SIGNAGE WILL BE INSTALLED AS REQUIRED BY 2016 CEC THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN THE GROUNDING ELECTRODE AND THE PANEL (OR INVERTER) IF SMALLER THAN #6 AWG COPPER WIRE PER CEC 250-64B. THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER CEC 250.64C. ALL EXTERIOR CONDUIT SHALL BE PAINTED TO MATCH ADJACENT SURFACES. THE PV CONNECTION IN THE PANEL BOARD SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION. CEC690.64(B)(7) SITE CONDITIONS SHALL PREVAIL IF NO SCALE IS GIVEN. DRAWINGS ARE NOT NECESSARILY TO SCALE. ALL DIMENSIONS SHALL BE VERIFIED BY SUBCONTRACTOR UPON COMMENCEMENT OF CONSTRUCTION. PER THE 2016 CA RESIDENTIAL CODE (CRC) § R314 & R315, 10 YEAR BATTERY SMOKE ALARMS SHALL BE INSTALLED IN EACH SLEEPING AREA AND HALLWAYS LEADING TO SLEEPING AREAS. V1 1144& energy Infinity Energy 3855 Atherton Rd Rocklin, CA 95765 T: (888)-244-2513 CSLB:#998627 PROJECT INFORMATION NAME: JEFF DENEAU ADDRESS: 52290 AVENIDA CITY; LA QUINTA STATE, ZIP: CA 92253 AHJ: CITY OF LA QUINTA APN#: 773-263-002 PROJECT#: K20692 FINANCE TYPE: CASH DRAWN BY: D.BONAR 6/11/2019 0ib i W - p i.e.r G 0 O' SI9NAbTM-RE AND DATE � p W CC Z Q C Z W p SHEET TITLE TITLE SHEET I SHEET NUMBER 0 IN �r FOAM R324.6.2 - PROVING ARRAYS TAKE LESS THAN 33% OF TOTAL ROOF AREA TOTAL ROOF AREA: 2233 sqft AREA OF ARRAYS: 3'3" x 65" ( PANEL DIMENSIONS) 3.25' x 5.417' = 17.60 sqft (PER PANEL) 17.60 soft/panel X 14 panels = 246.4 sqft (TOTAL PANEL AREA) PERCENTAGE OF TOTAL ROOF AREA: (246.4 sqft / 2233 sgft)(100)= 11.03% 11.03% < 33% AREA TAKEN BY SOLAR PANELS < 33% OF TOTAL ROOF AREA R324.6.1: NOT LESS THAN TWO MINIMUM 36-INCH-WIDE PATHWAYS ON SEPARATE ROOF PLANS, FROM LOWEST ROOF EDGE TO RIDGE, SHALL BE PROVIDED ON ALL BUILDINGS. AT LEAST ONE PATHWAYS SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY, A MINIMUM 36-INCH-WIDE PATHWAY FROM THE LOWEST ROOF EDGE TO THE RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE AS THE PHOTOVOLTAIC ARRAY, ON AN ADJACENT ROOF PLANE, OR STRADDLING THE SAME AND ADJACENT ROOF PLANES. PATHWAYS SHALL BE OVER AREAS CAPABLE OF SUPPORTING FIRE FIGHTERS ACCESSING THE ROOF. PATHWAYS SHALL BE LOCATED IN AREAS WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES, CONDUIT, OR MECHANICAL EQUIPMENT R324.6.2: FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, NOT LESS THAN 18-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, NOT LESS THAN 36-INCH CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. AZIMUTH AND SLOPE MOUNTING PLANE I MP1 I AZIMUTH I N/A I I TILT (degrees) 1 0 1 MODULE COUNT 1 14 LEGEND: T SETBACK f- Q H Z Z 2 CITY OF LA OUkTA r ° a c� BUILDING DIVISIONQ � REVIEWED FOR oIf " Y � O OD o ~ f�OMPL ANCE r Z 0 w z i V=°z w Q 0- u- O SOLAREDGEINVERTER: SE3000H-US Q MAIN SERVICE PANEL Q QZ LLJ W Z M Lo C) Q Z N u- o M EXTERNAL %" CONDUIT LL N LuNa< � Sri ■JUNCTION 1307 r■R ai rii J'�+��►fir►i► ►► t+ ■ ■ r s, rAf N Scale: 1" = 10' N O w Q J w � Co 0Z UI M LLJO<LoN z�QNCD U 00 M �F-- - JN* Q �LU0m Y 00 ?co�F-U 9 ['w►mF CHEMCURB SYSTEM WITH 1-PART POURABLE SEALER (SEE ATTACHED SPEC SHEETS) DEAD LOAD FIGURES PANEL WEIGHT (pounds) 42.5 WEIGHT (pounds) / SQ FT 2A RACK WEIGHT (pounds / lin. ft.) 0.811 WEIGHT(pounds) / SQ FT 0.44 LBS MAX LBS PER SQ FT 2.84 LBS MAX SQ FT / FASTENER 6 sq ft MAX LBS/FASTENER 17LBS ROOF ATTACHMENT DETAIL Scale: 1" = 1' %s" x 3" LAG 2-Y" EMBEDMENT MIN. f FOAM LAYER SPACING OF MOUNTS ARE MAXIMUM 6'SPAN- CITY OF LA OUINTA BUILDING DIVISION REVIE ED ; OIL CODE COMPLIANCE DATE B i Fr,Fn�n� ® X SETBACK 8/1 /2019 s Scale: 1" = 10' Co O w F- Z) O ZZ = Q � Q J _O �' � Q co U W <J LLj LL Y In- J Ow OAF}— C) Z tuw O 2 UwZ U=0z a- wQ�w O ry n Q D0 Qz Z w Q M w Q z N LL 0) O) LL N iLoaU n/ Co U' Z Lo Co LJJO<L0N ZafoC w o(D uJ i-=z rn m Q Y Z �Lp L f) 00 zC'.)W 0 iz TAG DESCRIPTION COMPONENT SOLAREDGE POWER OPTIMIZER 14 SOLAR EDGE P320 STRING OF SOLAR PV MODULES IN SERIES 14 LONGI: LR6-60PB-305M J-BOX SNAPNRACK JUNCTION BOX SOLAREDGE INVERTER 1 SOLAREDGE INVERTER: SE3000H-US (E) MAIN ELECTRICAL SERVICE PANEL 100A RATED, 240V, 2P, WITH 100A MAIN BREAKER M CONTINUOUSLY GROUNDED PV SOURCE AND PV OUTPUTS SHALL NOT BE CONTAINED IN THE SAME RACEWAY, CABLE TRAY, CABLE. OUTLET BOX, JUNCTION BOX, OR SIMILAR FITTING AS CONDUCTORS, FEEDERS, BRANCH CIRCUITS OF NON-PV SYSTEMS, OR INVERTER OUTPUT CIRCUITS UNLESS CONDUCTORS OF THE DIFFERENT SYSTEMS ARE SEPARATED BY A PARTITION. PV SYSTEM CONDUCTORS SHALL BE INDENIFIED AND GROUPED AS REQUIRED. BY 690,31 (B)(1) THJHROUGH (4). THE MEANS OF IDENIFICATION SHALL BE PERMITTED BY SEPERATE COLOR CODING, MARKED TAPE, TAGGING, OR OTHER APPROVED MEANS. CITY OF LA-um"GA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE H Q Z z U) CJrnU Q Q c) J U .. p ? F- O�Uw Z Uwz U W U=[)fZ W W Q0-LL O a Q �o Q- LLI zQ w¢c� LLIcl z N LLCDCN �� 0) u- 04 a )LoaC) 0 z M O 0) — r-- W H< Lo N wwV � 00 N � Q J m Z � U 0000 ?°OAF-U io) REQ'D BY CEC 690.54 & 705.12_(D)4) APPLY TO: AC DISCONNECT REQ'D BY CEC 690.54 & 705.12 D (4) APPLY TO: MAIN SERVICE PANEL LOAD CENTER COMBINER BOX INVERTER SIGNAGE LETTERING TO BE 3/g' WHITE ON RED BACKROUND. UV RESISTANT STICKERS. REQ'D BY CEC 705.12 (D)(4 APPLY TO: MAIN SERVICE PANEL REQ'D BY CEC 690.56 (C APPLY TO: MAIN SERVICE PANEL REQ'D BY CEC 690.53 APPLY TO: STRING INVERTER REQ'D BY NEC 690.17 APPLY TO: MAIN SERVICE PANEL REQ'D BY CEC 690.5(C) APPLY TO: STRING INVERTER cil,y OF LA C WNTA � DUILDNDIVISION �OR REVIEWED CODE COMPLIANCE 0 W Q H Z z 2 O�04U. agow LL Y � O C� Z 0 H W U U J W Z U ) z m U=0�z < a- J w O a (7 Z ij cy) 0 0a) z 0 U(-) o �0-) H .J —r. Q 00 IZi Y Lo V 0 00 m ?O 1-U m a c N 00