The Design and Development Department has reviewed your Minor Adjustment
application (MA 2019-0006), pursuant to Section 9.210.040 of the City of La Quinta
Zoning Code.
REQUEST:
Grant up to a 10% adjustment to decrease the current garage width by 1’ -6”, from 20 ft.
to 18 ft. 6 in. to accommodate a third car garage enclosure, per the attached exhibits.
DECISION:
Approval is granted for the requested adjustment based on the following findings and
subject to the conditions of approval listed below:
1. Minor Adjustment 2019-0006 is consistent with the La Quinta General Plan, in
that the proposal does not alter the approved land use for the property or affect
land use on surrounding similar properties.
2. Minor Adjustment 2019-0006 is consistent with the intent of the La Quinta
Zoning Code in that the requested adjustment will be conditioned to comply with
all other development standards as required under said Zoning Code.
3. Processing and approval of Minor Adjustment 2019-0006 is in compliance with
the California Environmental Quality Act. The adjustment requested falls under
CEQA Guidelines Section 15305(a) as a “Minor Alterations in Land Use
Limitations” - Class 5 Categorical Exemption.
4. Approval of Minor Adjustment 2019-0002 is not detrimental to the public health,
safety and general welfare, nor injurious or incompatible with other properties
and land use in the vicinity. The adjustment has no impact on health or safety
issues and will not affect physical land use characteristics in the vicinity.
CONDITIONS OF APPROVAL:
1. A building permit shall be obtained prior to construction.
2. The proposed construction shall comply with all other development standards as
required under the La Quinta Zoning Code.
Please be advised that the City only approves three Minor Adjustments per lot, regardless
of the percentage of the development standard adjusted. This approval relates only to
allowance of the adjustment as stated above and does not imply any entitlement or
approval of a building permit for any structures shown on the plans on file. All other
development standards of the La Quinta Zoning Code are applicable and shall be adhered
to in preparing plans for building plan check.
If you have any additional questions, please contact me at 760-777-7069.
Sincerely,
Carlos Flores, Senior Planner
Design and Development Department
EXISTING RESIDENCE
SETBACK
EXISTING GARAGE GARAGE
CONVERSION
187.00 S.F.
PROPERTY LINE 60.00'PROPERTY LINE 155.60'PROPERTY LINE 111.10'PROPERTY LINE 30.00'PROPERTY LINE 56.95'PRO PE RT Y L INE56.9
5
'
5'-0"
5'-0"20'-0"25'-0"SETBACKSETBACK
SETBACKEXISTING POOL
EXISTING SPA
N O L A N C I R C L EGAS METERVERIFYMAIN PANEL+/- 26'-3"+/
-
48
'
-1
"
1. ALL WORK,MATERIALS AND METHODS SHALL BE IN
CONFORMANCE WITH THE 2016 CBC CODES, 2016 CPC, 2016 CMC
AND 2016 CEC CODE EDITIONS. ORDINANCES AND REGULATIONS
OF ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION AT THE
PROJECT LOCATION.
2. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR
VERIFYING ALL DIMENSIONS AND EXISTING CONDITIONS THEREON
BEFORE COMMENCING WORK. REPORT ANY DISCREPANCIES
AND/OR POTENTIAL PROBLEMS TO THE ARCHITECT PRIOR TO
PROCEEDING WITH AFFECTED WORK.
3. CONTRACTORS ARE RESPONSIBLE FOR ALL WORK
REGARDLESS OF THE LOCATION OF THE INFORMATION OF THE
DOCUMENTS.
4. PROVIDE PIPE GUARDS AT ALL ABOVE GROUND UTILITY
EQUIPMENT AS DICTATED BY GOVERNING AGENCIES.
5. PROVIDE PEDESTRIAN OR VEHICULAR PROTECTION
BARRICADES TEMPORARY GUARD RAILS, AND / OR CANOPIES AS
REQUIRED BY THE LOCAL AGENCIES OR AS NECESSARY FOR
PEDESTRIAN AND VEHICULAR SAFETY.
6. THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR
COORDINATION AMONG HIS VARIOUS SUBCONTRACTORS.
7. IN THE EVENT OF DISCREPANCIES BETWEEN ANY DRAWINGS
AND/OR SPECIFICATIONS, THE MORE COSTLY OR MORE
RESTRICTIVE CONDITIONS SHALL BE DEEMED THE CONTRACT
REQUIREMENT, UNLESS OTHERWISE STATED IN WRITING, FROM
THE DESIGNER. GENERAL CONTRACTOR SHALL COORDINATE ALL
UNDERGROUND ITEMS WITH THE PLUMBING, ELECTRICAL, GAS
DRAWINGS . CONTRACTOR SHALL VERIFY DIMENSIONS OF ALL
EQUIPMENT MANUFACTURERS.
8. GENERAL CONTRACTOR SHALL NOTIFY ALL APPLICABLE LOCAL
GOVERNING, AUTHORITIES AND UTILITIES PRIOR TO COVERING UP
ANY WORK REQUIRING INSPECTION.
9. PROVIDE GALVANIC PROTECTION BETWEEN DISSIMILAR
MATERIALS WHERE REQUIRED.
10. ALL PENETRATIONS THROUGH ANY SURFACE SHALL BE
THOROUGHLY SEALED WITH APPROPRIATE SEALANT MATERIAL.
UNLESS OTHERWISE NOTED
11. ALL EXTERIOR AND INTERIOR EXPOSED METAL, TRIM,
TREILLAGE,RAILINGS, MOLDING, FRAMES, CASTING, ETC., SHALL
BE PAINTED.
12. ALL METALLIC UTILITY LINES SHALL BE CORROSION
PROTECTION.
14. ALL CONSTRUCTION AND DETAILS SHALL COMPLY WITH THE
CITY OF PALM SPRINGS BUILDING CODE AND ITS ADOPTIONS, AND
WITH ALL OTHER APPLICABLE FEDERAL, STATE AND LOCAL
ORDINANCES.
15. ANY/ALL LUMBER IN CONTACT WITH CONCRETE FLOOR OR
FOOTINGS SHALL BE F.G. REDWOOD OR PRESSURE TREATED .
16. ALL FRAMING LUMBER SHALL BE GRADE MARKED WITH
QUALITY PER C.B.C. (CALIFORNIA BUILDING CODE)
REQUIREMENTS.
17. EACH GENERAL ENGINEERING CONTRACTOR, GENERAL
BUILDING CONTRACTOR, AND SWIMMING POOL CONTRACTOR
SHALL FURNISH THE CITY WITH A LIST OF EACH SUBCONTRACTOR
UNDER HIS CONTROL OR DIRECTION, AND EACH
SUBCONTRACTOR SHALL HAVE OBTAINED A BUSINESS LICENSE
BEFORE THE FINAL INSPECTION ON A BUILDING OR STRUCTURE
SHALL BE GIVEN BY THE BUILDING AND SAFETY DEPARTMENT.
(PALM DESERT MUNICIPAL CODE 5.06.010)
18. ACCESSORY DWELLING UNITS (<1,200 SQUARE FEET) NEED
NOT TO HAVE FIRE SPRINKLERS, WHETHER ATTACHED OR
DETACHED, PROVIDED THE PRIMARY HOME DOES NOT HAVE A
FIRE SPRINKLER SYSTEM. SENATE BILL 1069
19EXISTING NON COMPLIANT FIXTURES (TOILETS THAT US MORE
THAN 1.6 GALLONS OF WATER PER FLUSH, URINALS THAT USE
MORE THAN ONE GALLON OF WATER PER FLUSH, SHOWERHEADS
THAT HAVE A FLOW CAPACITY OF MORE THAN 2.5 GALLONS OF
WATER PER MINUTE, AND INTERIOR FAUCETS THAT EMIT MORE
THAN 2.2 GALLONS OF WATER PER MINUTE) SHALL BE REPLACED.
CERTIFICATION OF COMPLIANCE SHALL BE GIVEN TO THE
BUILDING INSPECTOR PRIOR TO FINAL PERMIT APPROVAL.
CALIFORNIA SB407.
20. COMPLIANCE WITH THE DOCUMENTATION REQUIREMENTS OF
THE 2016 ENERGY EFFICIENCY STANDARDS IS NECESSARY FOR
THIS PROJECT. REGISTERED, SIGNED, AND DATED COPIES OF THE
APPROPRIATE CF1R, CF2R, AND CF3R FORMS SHALL BE MADE
AVAILABLE AT NECESSARY INTERVALS FOR BUILDING INSPECTOR
REVIEW. FINAL COMPLETED FORMS WILL BE AVAILABLE FOR THE
BUILDING OWNER.
21. A LICENSED ENGINEER OR SURVEYOR SHALL STAKE THE
PROPERTY CORNERS OF THE SUBJECT LOT. AT THE TIME OF THE
UNDERGROUND PLUMBING INSPECTION, AND PRIOR TO CALLING
FOR ANY FOOTING INSPECTIONS FOR THESE PROJECTS, THE
CONTRACTOR SHALL PROVIDE STRING LINES ALONG THE
PROPERTY LINES ADJACENT TO THE PROPOSED WALL LINES OF
THE NEW CONSTRUCTION.
22. EACH GENERAL ENGINEERING CONTRACTOR, GENERAL
BUIDLING CONTRACTOR, AND SWIMMING POOL CONTRACTOR
SHALL FURNISH THE CITY WITH A LIST OF EACH SUBCONTRACTOR
UNDER HIS CONTROL OR DIRECTION, AND EACH
SUBCONTRACTOR SHALL HAVE OBTAINED A BUSINESS LICENSE
BEFORE THE FINAL INSPECTION ON A BUILDING OR STRUCTURA
SHALL BE GIVEN BY THE BUILDING AND SAFETY DEPARTMENT.
(PALM DESERT MUNICIPAL CODE 5.06.010)
PROJECT IS APPROVED UNDER
CITY OF LA QUINTA
SHEET INDEX
PROPERTY OWNER:
LOUISA DAVIS
78-750 NOLAN CIRCLE
LA QUINTA, CA 92260
PROJECT ADDRESS
78-750 NOLAN CIRCLE
LA QUINTA, CA 92260
APN: 604-233-020
LEGAL DESCRIPTION:
LOT 189 MB 213/067 TR 23268
PROJECT AREAS
LOT SIZE: 8,190 S.F. 0.188 AC.
EXISTING RESIDENCE: 1,591.00 S.F.
GARAGE CONVERSION: 187.00 S.F.
TOTAL LIVING AREA: 1,778.00 S.F.
LOT COVERAGE: 26%
BUILDING DATA:
ZONING: RL
OCCUPANCY TYPE: R3/U
CONSTRUCTION TYPE: VB
FIRE SPRINKLERS: NO
EXISTING RESIDENCEYEAR BUILT: 1995
PROJECT DATA
1-800
TWO WORKING DAYS BEFORE YOU DIG
422-4133
Underground Service Alert
Call: TOLL FREE
YEAR ROUND 7:00AM TO 7:00PM ON WEEKDAYS
8:00AM TO 5:00PM ON SATURDAYS
PROHIBITED ON SUNDAYS AND HOLIDAYS.
CONSTRUCTION HOURS
SCALE: 1/8= 1'-0"
ALL EXISTING CONDITIONS SHALL BE
VERIFIED BY THE GENERAL
CONTRACTOR..
SITE PLAN
GENERAL NOTES
DEPARTMENT OF CODE COMPLIANCE:
ALL CONTRACTORS AND SUBCONTRACTORS SHALL HAVE A CURRENT
BUSINESS LICENCE PRIOR TO PERMIT ISSUANCE PER MUNICIPAL
CODE, TITLE 5. ALL CONTRACTORS AND/OR OWNER-BUILDERS MUST
SUBMIT CERTIFICATE OF WORKER'S COMPENSATION INSURANCE
COVERAGE PRIOR TO THE ISSUANCE OF A BUILDING PERMIT PER
CALIFORNIA LABOR CODE, SECTION 1800. GENERAL CONTRACTORS
AND/OR OWNER-BUILDERS SHALL COMPLETE AND SUBMIT A
CONTRACTOR'S LIST FROM THE DEPARTMENT OF CODE COMPLIANCE
PRIOR TO REQUEST FOR FINAL INSPECTION.
DEPARTMENT OF BUILDING AND SAFETY :
APPROVED TEMPORARY SANITARY FACILITIES ( I.E. CHEMICAL
TOILETS) SHALL BE IN THE CONSTRUCTION SITE PRIOR TO REQUEST
FOR FIRST INSPECTION ). HEALTH AND SAFETY CODE SECTION 5406.
CONTRACTOR AND/OR OWNER SHALL PROVIDE A TRASH BIN TO
INSURE PROPER CLEAN-UP OF ALL BUILDING MATERIALS. STORAGE OF
BUILDING MATERIALS OR DEBRIS SHALL BE CONFINED TO THE LOT FOR
WHICH THE PERMIT IS ISSUED. ADJACENT VACANT PROPERTIES MAY
NOT BE UTILIZED FOR THIS PURPOSE UNLESS WRITTEN PERMISSION
OF THE OWNER IS ON FILE WITH THIS OFFICE. THE PUBLIC RIGHT OF
WAY SHALL BE MAINTAINED IN A CLEAR CONDITION AT ALL TIMES.
2016 CALIFORNIA BUILDING CODE CBC
2016 CALIFORNIA RESIDENTIAL CODE CRC
2016 CALIFORNIA MECHANICAL CODE CMC
2016 CALIFORNIA PLUMBING CODE CPC
2016 CALIFORNIA ELECTRICAL CODE CEC
2016 CALIFORNIA FIRE CODE CFC
2016 CALIFORNIA GREEN BUILDING STANDARDS CODE CALGREEN
2016 CALIFORNIA ENERGY CODE CEC
TITLE 24, PART 2, CALIFORNIA ADMINISTRATIVE CODE HANDICAP
COMPLIANCE REGULATIONS AND ALL OTHER LOCAL CODES,
ORDINANCES AND STATE AMENDMENTS.VICINITY MAP
NO.SHEET NAME
GENERAL
A1.10
TITLE SHEET / SITE PLAN
PROJECT SCOPE
A1.10 TITLE SHEET - SITE PLAN
A2.10 FLOOR PLANS
A3.10 ELEVATIONS / DETAILS
MEP1.10 MECHANICAL / ELECTRICAL / PLUMBING
T24-1 T24
T24-2 T24
T24-3 T24
GARAGE CONVERSION
CONVERT 187 SF OF EXISTING GARAGE INTO LIVABLE SF.
NEW ELECTRICAL LAYOUT AT GARAGE CONVERSION
NEW MECHANICAL SUPPLY AT GARAGE CONVERSION
LAUNDRY UNIT RECONFIGURATION
A L L D R A W I N G A R E T H E P R O P E R T Y O F D E S E R T D E S I G N
C O L L A B O R A T I V E , A N D A R E O N L Y T O B E U S E D A S A N
I N S T R U M E N T O F S E R V I C E . T H E S E D R A W I N G S S H A L L N O T BE
REPRODUCED OR MODIFIED IN ANY WAY WITHOUT THE WRITTEN
CONSENT FROM DESERT DESIGN COLLABORATIVE. SUBMISSION
OF THESE DRAWINGS TO ANY THIRD PARTY DOES NOT RELEASE
IN AN Y WAY T H E CO P YR IGH T A N D O W N E R S H IP OF D R A W ING S
P R O V I S I O N S L I S T E D H E R E I N .
STATUS
DATE
PROJECT #
FIRST SUBMITTAL
07/29/2019
19050
SHEET NAME
74-818 VELIE WAY, STE 3
PALM DESERT, CA 92264
T: 760-219-3068
F: 760-219-3069
D E S E R T C O L L A B O R A T I V E D E S I G N
D R A F T I N G , D E S I G N , A N D P E R M I T S E R V I C E S
DESIGNER
OWNER
LOUISA DAVIS
ADDRESS
78-750 NOLAN CIRCLE
LA QUINTA, CA 92253
PROJECT TYPE GARAGE CONVERSION
REVISIONS
NO.DESCRIPTION DATE
D E S E R T C O L L A B O R A T I V E D E S I G N @ M A I L . C O M
1 1ST PLAN CHECK 08/28/19
1
1
1
PLANNING APPROVAL
ADMINISTRATIVE
CASE# ____________________
EXHIBIT# ____________________
INITIAL cflores
DATE 09/25/2019 4:06:22 PM
MA2019-0006
EXISTING WALL
TO BE DEMOLISHED
EXISTING WALL TO REMAIN -
PROTECT IN PLACE
WALL LEGEND
D01
(E) GARAGE(E) POWDERROOM(E) BEDROOM 1(E) BEDROOM 2(E) MASTER BEDROOM(E) MASTERCLOSET(E) MASTER BATH(E) LIVING ROOM(E) DINING ROOM(E) KITCHEN(E) MORNINGROOM(E) FOYER(E) HALL(E) BATH 1D02
D03 D03
NEW 2X WALL
W/ INSULATION PER T24
WALL LEGEND
(E) GARAGE(E) POWDERROOM(E) BEDROOM 1(E) BEDROOM 2(E) MASTER BEDROOM(E) MASTERCLOSET(E) MASTER BATH(E) LIVING ROOM(E) DINING ROOM(E) KITCHEN(E) MORNINGROOM(E) FOYER(E) HALL(E) BATH 1(N) BEDROOM 3-4" FROM F.F.100
100
100
100101
102
A
C
B
D
E
F 01
02
18'-612"10'-812"20'-1"2'-8"2'-512"14'-1112"5'-2"
7'-0"3'-812"
03 04
05
07
08
09
10
11
1213
1415
16
17
G
06
ABOVE
H
I
MIN. GARAGE DIMENSION REQUIRED: 20'-0"
MINOR ADJUSTMENT ALLOWS A 10% REDUCTION: 20'-0" - 10% = 18'-0"
ACTUAL DIMENSION PROVIDED = 18'-6.5" > 18'0"
PER THE CITY OF LA QUINTA, A 10% VARIANCE IS ALLOWED IF APPROVED BY THE
CITY THROUGH APPLYING FOR A MINOR ADJUSTMENT
D04 D05
4'-0"5'-412"SLOPE
SLOPE
SLOPE SLOPESLOPE08
A3.10
SYM.
01
WIDTH
4'-0"
HEIGHT
4'-0
GLAZING REMARKSTYPE
SLIDER
WINDOW SCHEDULE
U-FACTOR SHGC
02 0'-10"6'-8"
TEMPERED
SYM.
A
WIDTH
3'-0"
HEIGHT
6'-8"
U FACTOR
DOOR SCHEDULE
TYPE REMARKS
SOLID CORE / GLASS 14 S.F. OF GLASS
GLAZING
TEMPERED
B 6'-0"6'-8"LOUVERED
C 6'-0"6'-8"
D 2'-6"6'-8"
E 2'-6"6'-8"
F 16'-2"7'-0"
SELF CLOSING, SELF LATCHING, SOLID CORE OR
LISTED 20 MINUTE ASSEMBLY(E) SOLID CORE
(E) SOLID CORE
(E) GARAGE
FRAME
VINYL
PROVIDE MINIMUM 100 SQ. IN. OPENING FOR VENTILATION
LOUVERED PROVIDE MINIMUM 100 SQ. IN. OPENING FOR VENTILATION
FIXEDTEMPEREDVINYL
03 2'-0"5'-0"CASEMEMTTEMPEREDVINYL
04 3'-0"5'-0"TEMPEREDVINYL
05 0'-10"6'-0"TEMPEREDVINYL
06 4'-0"1'-6"VINYL
07 2'-0"5'-0"TEMPEREDVINYL
08 3'-0"5'-0"TEMPEREDVINYL
09 2'-0"5'-0"TEMPEREDVINYL
10 5'-0"3'-0"TEMPEREDVINYL
11 5'-0"5'-0"TEMPEREDVINYL
12 5'-0"5'-2"TEMPEREDVINYL
13 4'-0"4'-0"VINYL
14 3'-0"5'-0"TEMPEREDVINYL
15 3'-0"5'-0"TEMPEREDVINYL
16 4'-0"1'-6"VINYL
17 6'-0"4'-0"TEMPEREDVINYL
CASEMEMT
SLIDER
SLIDER
FIXED
FIXED
GLASS BLOCK
SLIDER
FIXED
SLIDER
SLIDER
CASEMEMT
CASEMEMT
CASEMEMT
FIXED
G 3'-0"6'-8"SOLID CORE / GLASS 14 S.F. OF GLASSTEMPERED
H 6'-0"6'-8"SOLID CORE / GLASS 28 S.F. OF GLASSTEMPERED
I 6'-0"6'-8"SOLID CORE / GLASS 28 S.F. OF GLASSTEMPERED
NOTE 1:
LIGHTING REQUIREMENTS =8% OF S.F.
VENTILATION REQUIREMENTS =4% OF S.F.
(N) GARAGE CONVERSION =187 S.F.
187 S.F. X .08 =14.88 S.F. OF LIGHTING REQUIRED
187 S.F. X .04 =7.48 S.F OF VENTILATION REQUIRED
16 S.F. OF LIGHTING IS PROVIDED AT NEW GUEST BEDROOM
8 S.F. OF VENTILATION IS PROVIDED AT NEW GUEST BEDROOM
SEE NOTE 1 FOR LIGHTING AND VENTILATION REQUIREMENTS0.32 0.25
0.71 0.73
0.71 0.73
0.71 0.73
0.71 0.73
0.71 0.73
0.71 0.73
0.71 0.73
0.71 0.73
0.71 0.73
0.71 0.73
0.71 0.73
0.71 0.73
0.71 0.73
0.71 0.73
0.71 0.73
0.71 0.73
SHGC
0.32 0.25
0.71 0.73
0.71 0.73
0.71 0.73
EXISTING / DEMOLITION FLOOR PLAN 11/4" = 1'-0"
SCALE A2.10
FLOOR PLANS
EXISTING UTILITY SINK TO BE REMOVED. CAP ALL
ABANDONED UTILITY LINES.
EXISTING GARAGE DOOR, DOOR HARDWARE,
AND DOOR EQUIPMENT TO BE REMOVED. PREP
AREA FOR NEW INFILL FRAMING.
EXISTING WASHER / DRYER TO BE RELOCATED.
CAP ALL ABANDONED UTILITY LINES.
EXISTING FAU TO REMAIN. PROTECT IN PLACE
EXISTING WATER HEATER TO REMAIN. PROTECT
IN PLACE. SEE DETAIL 10 / MEP1.10
GARAGE SHALL BE SEPARATED FROM THE
RESIDENCE AND ITS ATTIC AREA BY NOT LESS
THAN 1/2 INCH GYPSUM BOARD APPLIED TO THE
GARAGE SIDE (AT WALLS). GARAGES BENEATH
HABITABLE ROOMS SHALL BE SEPARATED BY
NOT LESS THAN 5/8 INCH TYPE 'X' GYPSUM
BOARD. SECTION R302.6
NEW DRYER. SEE DETAIL 6 / MEP1.10 FOR
EXHAUST DETAILS
NEW WASHER
D01
KEYNOTES
D02
A L L D R A W I N G A R E T H E P R O P E R T Y O F D E S E R T D E S I G N
C O L L A B O R A T I V E , A N D A R E O N L Y T O B E U S E D A S A N
I N S T R U M E N T O F SE R V I C E . T H E S E D R A W I N G S S H A L L N O T B E
REPRODUCED OR MODIFIED IN ANY WAY WITHOUT THE WRITTEN
CONSENT FROM DESERT DESIGN COLLABORATIVE. SUBMISSION
OF THESE DRAWINGS TO ANY THIRD PARTY DOES NOT RELEASE
IN A N Y WAY T H E CO P YR IGHT A N D O W N E R S H IP O F D R A W INGS
P R O V I S I O N S L I S T E D H E R E I N .
STATUS
DATE
PROJECT #
FIRST SUBMITTAL
07/29/2019
19050
SHEET NAME
74-818 VELIE WAY, STE 3
PALM DESERT, CA 92264
T: 760-219-3068
F: 760-219-3069
D E S E R T C O L L A B O R A T I V E D E S I G N
D R A F T I N G , D E S I G N , A N D P E R M I T S E R V I C E S
DESIGNER
OWNER
LOUISA DAVIS
ADDRESS
78-750 NOLAN CIRCLE
LA QUINTA, CA 92253
PROJECT TYPE GARAGE CONVERSION
REVISIONS
NO.DESCRIPTION DATE
D E S E R T C O L L A B O R A T I V E D E S I G N @ M A I L . C O M
1 1ST PLAN CHECK 08/28/19
D03
NEW FLOOR PLAN 21/4" = 1'-0"
SCALE
100
101
102
DOOR AND WINDOW SCHEDULE 11/4" = 1'-0"
SCALE
D04
D05
1
1
1
PLANNING APPROVAL
ADMINISTRATIVE
CASE# ____________________
EXHIBIT# ____________________
INITIAL cflores
DATE 09/25/2019 4:06:50 PM
MA2019-0006