BMCH2019-03844V
78-495 CALLE TAMPICO C& 0 D aaba VOICE (760) 777-7125
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011
DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 9/20/2019
Permit Type/Subtype:
MECHANICAL/ Owner:
Application Number:
BMCH2O19-0384 MATTHEW FINLEY
Property Address:
53455 AVENIDA VALLEJO
APN:
774082022 LA QUINTA, 92253
Application Description:
FINLEY / HVAC CHANGEOUT
Property Zoning:
Application Valuation:
$6,885.00
Applicant: i� D
Contractor:
IE INC AG s TIMO'S AIR CONDITIONING & HEATING INC
31225 LA BAYA D72232 CORPORATE WAY
WESTLAKE VILLAGE, CA 91362 p THOUSAND PALMS, CA 92276
�r �� Z019 (760)770-4357
Llc. No.: 920062
CITY OF LA QUINTA
-------------------M- IG+EIMEIAPMENTDEPARTMENT ----------------------------------
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9
{commencing with Section 70001 of Division 3 of the Business and Professions Code, and
my License is in full force and effect.
License Class: C20 License No. 920062
c
Date: 1 - I Contractor: w ��
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any
structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the
alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that he
or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to
construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State
License Law does not apply to an owner of property who builds or improves thereon,
and who contracts for the projects with a contractor(s) licensed pursuant to the
Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Addre!
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of _the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My workers' compensation insurance carrier and policy number are:
Carrier: NNC RGUARO INSURANCI COMPANY Policy Number: TIWC056706
_ I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: r� 2.0 I Applicant: [
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit issued
as a result of this application , the owner, and the applicant, each agrees to, and shall
defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not
commenced within 180 days from date of issuance of such permit, or cessation of work
for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the above -
mentioned property for inspection purposes.
Date Signature (Applicant or Agent)
Date: 9/20/2019
Application Number:
Property Address:
APN:
Application Description:
Property Zoning:
Application Valuation:
BMCH2019-0384
53455 AVENIDA VALLEJO
774082022
FINLEY / HVAC CHANGEOUT
$6,885.00
Applicant:
IE INC
31225 LA BAYA
WESTLAKE VILLAGE, CA 91362
Owner:
MATTHEW FINLEY
LA QUINTA, 92253
Contractor:
TIMO'S AIR CONDITIONING & HEATING INC
72232 CORPORATE WAY
THOUSAND PALMS, CA 92276
(760)770-4357
Llc. No.: 920062
Detail: HVAC CHANGE OUT - 14SEER/80AFUE SPLIT SYSTEM. CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. 2016
CALIFORNIA BUILDING CODES. A
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT CITY AMOUNT
BSAS SB1473 FEE
101-0000-20306 0 $1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
HVAC CHANGEOUT - SPLIT -SYSTEM
101-0000-42402
0
$40.25
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HVAC CHANGEOUT - SPLIT -SYSTEM PC
101-0000-42600
0
$80.50
Total Paid for MECHANICAL CHANGEOUT 2019: $120.75
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PERMIT ISSUANCE
101-0000-42404
0
$101.97
Total Paid for PERMIT ISSUANCE: $101.97
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RECORDS MANAGEMENT FEE
101-0000-42416
0
$10.00
Total Paid for RECORDS MANAGEMENT FEE: $10.00
DESCRIPTION
ACCOUNT QTY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611 0
$5.00771
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
ta Q"KraPERMITGEMfd,c DLSEWT-
PLAN LOCATION:
Project Address: 53455 Avenue Vallejo
Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech
APN #:
Replace 4 ton heat pump and air handler
Applicant Name: Steven Schnierer
Address: 31225 La Baya Drive Suite 213
City, ST, Zip: Westlake Village, CA 91362
Telephone: 818-735-7876
Email: swschnierer@roadrunner.com
Valuation of Project $ 6,885.00
Contractor Name: Timo's A/C & Heating
Address: 72232 Corporate Way
City, St, Zip Thousand Palms, CA 92276
Telephone: 760-770-4357
Email:
State Lic: 920062 City Bus Lic:
New SFD Construction:
Conditioned Space
Garage
Patio/Porch
Fire Sprinklers
SF
SF
SF
SF
Arch/Eng Name: Construction Type: Occupancy:
Address: Grading:
City, St, Zip
Telephone: Bedrooms: Stories: # Units:
Email:
State Lic: City Bus Lic:
Property Owner's Name: Matt Finley
Address: 53455 Avenue Vallejo
City, ST, Zip La Quinta, CA 92253
Telephone:
Email:
New Commercial / Tenant Improvements:
Total Building
Construction Type: Occupancy:
78495 CALLE TAMPICO
LA QU I NTA, CA 92253
760-777-7000
SF
Timo's Air Conditioning EE Heating, Inc.
Estimate 3497320
72232 Corporate Way
Job 3488676
NdR GCNaItrCluMO aXaAillq
Thousand Palms, CA 92276
Ucense N 920062
Estimate Date 9/4/2019
Customer PO
Billing Address
Matt Finley
Day and night
Task M
XR14HP48SYS
T4TWR4048G1000A
Estimate Details
Description
Trane Complete System
• Tonnage:
4-Ton Upflow
• Condenser:
Day & Night
Air Handler:
Day & Night
a Thermostat:
Honeywell T4
Includes:
• Labor
• Removal and Disposal
• Installation Items as Noted on Proposal
• HERS/Dud Testing
e City Permits
• 1 Advantage Plan Membership (2 Maintenance Visits)
Warranty:
e 10 Years Compressor
• 10 Years Parts
• 1 Year Labor
• R410A S/S H/P 14 SEER 4T
Trane T4TW R4048G 1000A
TTEM4A0C48S41SB
• R410A CONV A/H TXV 4T
Trane TTEM4AOC48S41 SB
Thank you for choosing Tirno's Air Conditioning
Job Address
Matt Finley
53455 Avenue Valle'o
La Clumta, CA 9225 USA
Quantity Your Price YourTotel
1.00 $6,885.00 $6,885.00
1.00 $0.00 $0.00
1.00 $0.00 $0.00
Member Savings $0.00
Sub -Total $6,885.00
Tax $0,00
Total $6,885.00
Est. Financing $159.73
• Notke of R)ghtto Gned You, the buy,. may —cel Ma he —ton at any de,. prbr b mbnlght of M, hhbd bufaae day left¢ Mo data of Mh benection To c.... IMa tansactlon, m,i o,deG„ e
dpnad end dated copy of Me wriWn ¢•... Nation notice Trine 0 C-Hafenc by alg.hg lab,,.. you agree b the Term, 9 Condidons bebw.
• Phelhn1r y Lan No&.. Upon accpunce OF pnpoul and coin mancemml of work no&. a caned en Ma pebon, end budnasa -the, at the hsteb don add,ees Isud show A MochanlcY Lan m,y be
plac,d on the property A balance le not pact in ful upon rompatbn AN orders not P.b b fu1 an wb)., to ,ppnvd fnm Me Compeny',.ndR dpenment. Thk P.F.eal may be."d— by M•
Company tnol accepted wehh M day. Unfi Rne1 payment b mAda, the Company IN nub bV, to A mt.d.a end pulP—t It hauls
e payAA marht T— 10% Dpo(up to$1,M) p...,capnonbn.e ol11Rate— to be pact com Upon paon dof hsb•lbn pnfttu may Oh,.".monep.Nk and lrequenl pbghe, p.y..t schedule
based upon the dalyesy of goeda and comphtbn of hetelad comp—ta Thal• pnOraa, p,ymenb en to be (pulled a the'D~ —flo- ,bay Fb•1 payment not to be delayed by third! parties
• Pymant a due to ful up,n completion of m"don Pay —A not contngant upon completion of Mbd pA am wch lac HERS (Duct Testlnp, MY pemb hm.,dan by cky, etc
• Cu a, shal uwm• rbl of to, or damage to aq,tp— W l a eat h puc, on M,)ob.
• The Company shal not be rasa—bl• for the upehw lncumd h n—hv g, "Wing er raflshbeg Pad of the buidbg abucbn n•cnnry for the Pedo,mence of any Aevke er b6labtbn,-1—
oM•hwW noted b the Pnpeesl
• The CompMy Anal not be 101. for Me MmNkatlpn,dau.ton, aMyemmkencpsualbn, sbnge, MMOVA or u•nepodatan pf eny rpul-d or h—rdous wbruncsa Regulated or haaerdaus wb,unces
may h,ad,, but en rat em W re, -Men• cen•h nM.—end nhbewt oK
9/4/2019
CERTIFICATE OF COMPLIANCE
Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC)
Project Name:
MATT FINLEY I Date Prepared:
CF1R-ALT 02-E
(Page 1 of 3)
2019-09-04
A. General Information
CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one
CF111-ALT-02 document for each dwelling unit.
01
Project Name
MATT FINLEY
02
Date Prepared
2019-09-04
03
Project Location
53455 AVENUE VALLEJO
04
Building Type
Single family
05
CA City
La Quinta
06
Dwelling Unit Name
MATT FINLEY
07
Zip Code
92253
08
Dwelling Unit Conditioned
1600
Floor Area (ft2)
Number of Space
09
Climate Zone
15
10
Conditioning (SC) Systems in
1
this Dwelling Unit:
B. Space Conditioning (SC) System Information
01
02
03
04
05
06
07
08
09
10
Is the SC
Installing a
SC System
SC System
CFA served
system a
refrigerant
Installing new SC
Installing
Installing
Installing
Identification or
Location or Area
by this SC
ducted
containing
system
more than 40
entirely new
entirely new
Name
Served
System (ft)
system?
component?
components?
feet of ducts?
duct system?
SC system?
Alteration Type
System 1
Location 1
1600
Yes
Yes
Yes
No
No
No
Altered spaceconditioning
system
C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)1Diib)
This section does not apply to this project.
Registration Number: 419-A020096745A-000-000-0000000-0000
Registration Date/Time: 2019-09-04 18:21:10
HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-09-04 18:21:10
Schema Version: rev 20180426
CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC) (Page 2 of 3)
D. Altered Space Conditioning System (Sections 150.2(b)1E and F)
01
02
03
04
05
06
07
08
09
10
11
12
Heating
Cooling
System
Heating
Altered
Heating
Minimum
Altered
Cooling
Minimum
Required
New or
Identification
System
Heating
Efficiency
Efficiency
Cooling
Cooling
Efficiency
Efficiency
Thermostat
Replaced
New Duct
or Name
Type
Components
Type
Value
System Type
Components
Type
Value
Type
Duct Length
R-Value
Central split
All new
Central split
All new
This field or
This field or
System 1
HP
heating
AFUE
0.8
HP
cooling
SEER
14
Setback
section is not
section is not
components
components
applicable
applicable
Required Documentation:
CF2R-MCH-01-E - Space Conditioning Systems
- Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16)
CF2R and MR-MCH-20-H - Duct Leakage Test required when heating or cooling components are installed In ducted systems, or when more than 40 ft of duct length is replaced
-Leakage rate compliance: <=15 percent or <= 10 percent leakage to outside, or seal all accessible leaks.
CF2R and MR-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15).
CF2R and CF3R-MCH-23 Airflow Rate >= 300 CFM per ton required when MCH-25 is required.
Exceptions:
Duct systems registered with HERS provider as previously sealed are exempt from MCH-20 Duct Leakage Testing requirements.
Heating -only systems and Air Handler Furnace changes do not require verification of Air Flow MCH-23, or Refrigerant Charge MCH-25.
Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH-20 Duct Leakage Testing requirements.
E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)iDiia and 150.2(b)1E, F)
This section does not apply to this project.
F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C)
This section does not apply to this project.
Registration Number: 419-A020096745A-000-000-0000000-0000 Registration Date/Time: 2019-09-04 18:21:10 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-09-04 18:21:10
Schema Version: rev 20180426
CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-IR-ALT HVAC) (Page 3 of 3)
Documentation Author's Declaration Statement
1.1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name
Documentation Author Signature:
Jo Anne Orona
o-A mwl Oranal
Company:
Signature Date:
I Permit E Raters
2019-09-04
Address:
CEA/ HERS Certification Identification (if applicable):
31225 La Baya Drive
City/State/Zip:
Phone:
Westlake Village CA 91362
818-735-7876
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer).
3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the
requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
5. 1 will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable
inspections. I understand that a registered copy of this Certificate of Compliance is required to be Included with the documentation the builder provides to the building owner at occupancy.
Responsible Designer Name:
Responsible Designer Signature:
Joey Timo
TIZU r��
Company:
Date Signed:
Timo's Air Conditioning & Heating
2019-09-04
Address:
License:
72232 Corporate Way
920062
City/State/Zip:
Phone:
Thousand Palms CA 92276 1760-770-4357
Digitally signed by CHEERS—. This digital signature is provided in order to secure the content of this registered
document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 419-A020096745A-000-000-0000000-0000 Registration Date/Time: 2019-09-04 18:21:10 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-09-04 18:21:10
Schema Version: rev 20180426