Loading...
BWFE2019-0199 Revision 1f., F i E RC - Project Address: 5 L' O-80 A,, C�6r APN #: Applicant Name: ,J Address: �L_,GI City, ST, Zip: Telephone: Email: 1?06 ® �S+ CJv ✓o�G.Gv�-� Property Owner's Name: Address: City, ST, Zip Telephone: Email: PERMIT # jL5 -F , PLAN LOCATION: Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech n lal l �a,; Valuation of Project T Zi New Commercial / Tenant Improvements: Total Building SE Construction Type: Occupancy: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 ORCO WALL SYSTEM STRUCTURAL CALCULATIONS PREPARED FOR CITY OF LA QUINTA 54-080 AVENIDA OBREGON LA QUINTA, CALIFORNIA ENGINEERING STAMP APPROVAL IS CONDITIONAL; REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS. RDUG0 �c m w I y' D rn NO B3660 * EXP. 03/31/2021 C 1 V % N, T E OF C4�-%f PREPARED BY CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE Ld FEa,.oi Q - o / ?gI 0 i ORCO BLOCK & HARDSCAPE % 11100 BEACH BLVD STANTON, CA. TEL. (714) 527-2239 FAX. (714) k 90680 3 fl0 897-1904 ORCO WALL SYSTEM FORCES PER 2016 CBC CHAPTER /6 L A (Qai An-W �_,4 WIND FORCES TO WALLS PER ASCE 7-10 SECTION 29.4 CHECK WIND FORCE CALCULATION FOR BASIC 85 MPH 8 95 MPH 3 SECOND GUST SPEED EXPOSURE C CONDITION USING ASCE 7-10 CHAPTER 29 WIND LOADS 8 USING SECTION 29.3.2 TO FIND THE 3 SEC. VELOCITY PRESSURE OH. QH= 0.00256 K z K ZT K D V 2 ... (29.3-1), WHERE: K z = 0.57 FOR EXP B AND K 2 = 0.85 FOR EXP C FROM TABLE 29.3-I: KZT = 1.0 DEFAULT PER SECTION 26.8-1 8 KD = 0.85 FROM SECTION 26.6-I THEREFORE, FOR 85 MPH 8 95 MPH 3 SEC. WIND GUST SPEED: ON=(0.00256)(0.85)(1.0)(0.85)(I10)2 = 22.4 PSF 8 QN =(0,00256)(0.85)(1.0)(0.85)(120)2 = 26.6 PSF NOW USING SECTION 6.5.14 FOR SOLID FREESTANDING WALLS: FN= ON G CF AS..(29.4-1), WHERE: G= 0.85 FROM SECTION 26.9.1 CF = 1.40 PER FIGURE 29.4-1 USING AVERAGE ASPECT RATIO (WALL LENGTH TO HIGTH) OF 2. NOTE: CF RANGES FROM 1.48 FOR A 5' WIDE RETURN WALL TO l.3 FOR A 60' PANEL. THEREFORE. FOR 110 MPH = (22.4 FSF)(0.85)0,4) A. = 26, 7 PSF. B FOR 120 MPH = (26.6 W)(G.M44) A. = 31.7 PSF: WIND FORCE FOR EXPOSURE C CONDITIONS V,,,,T IN MPH I00 110 120 /30 140 1501 ON = 0.00256 Ki X, K. V` 1 18.5 PSF 22-4 PSF 26,6 PSF J2,1 PSF 36,J PSF 41.6 PSF wNERE K.= 0.85, K.,= 1.0, K., 0,85 F„ = WINO FORCE PER SO, FT. Fw = Q. G C, A. PER SECTION 29,4-I 22, 0 PS 26.7 PS 3/.7 PSF 38.4 PSF 43.2 PSF 49.5 PSF WHERE G=0.85 AND C•= 1,4 AVE, - F. = WIND FORCE BY USING 0,60 LOAD 78 1. BS 93 101 108 /l6 FACTOR PER CBC 1605, J./ EON 16-5, PROJEC T S1 TE WIND ZONE: V UL T = //0 MPH EXPOSURE C THEREFORE WIND FORCE = 2(0 , PSF <-- SEISMIC FORCES PER 2016 CBC (ASCE 7-10 SECT. 15,4.IB) e gFESSrDti FOR NONBUILDING STRUCTURES:�- - FREE STANDING WALLS AND PILASTERS �° Q - PROJECT SITE CLASS D v - FUNDAMENTAL PERIOD T GREATER THAN 0.06 SEC CALCULATED USING EQUATION 12.8-7 AND TABLE 12.8-2 * EV, 01d1/1f>2( CIV�1. B QP CpLL119 PER EON. 15.4-2, SEISMIC BASE SHEAR FOR FLEXIBLE NONBUILD/NG STRUCTURES NOT SIMILAR TO BUILDINGS: V= [(0.80)(S,)/(R/01 W , WHERE I = 1.0 8 FA = I.I FROM TABLE 11.4-1 B R = J.0 FROM TABLE 15.4.2 SEISMIC FORCE FOR I SEC. PERIOD CONDITIONS S, FROM FIG. 22-2 60 70 1 80 1 90 1 /00 1/0 V = I(0.80)(S0,'(R/1)] W 0.22W 0.24W1. 0.25W 0.27W I 0. 30W 0.32W PROJEC T S1 TE SEISMIC I NFORMA TION. S I=?v S V =0. 2 y W CMU WALL WEIGHTS PER SO. FT. BLOCK TYPE 6' CMU W/ JOINT REINFORCEMENT 8' CMU PILASTER GROUTED 0 O/C 48'0/C 4010/C 3210/C 2410/C /6'0/C 32'pIC 24'0/C 16'O/C SOLID SOLID WT. PER SO„ FT. 34 PSF 35 PSF 37 PSF 39 PSF 45 PSF 48 PSF 52 PSF 60 PSF 80 PSF 160 PSF THEREFORE SEISMIC FORCE IS: V = (D, 2 y)(3 7- PSF) = 8' , e 8 PSF ORCO 6' HIGH WALL W/ 2'-0" - 4'--0" RETAINING FOR 110 MPH WIND 3 SEC" GUST 0) EXP C DESIGN CRITERIA PER 20I6 GW 1. SOIL BEARING PRESSURE -1500 PSF + V3 INCR. FOR WIND OR SEISMIC EQUIVALENT FLUID PRESSURE = 45 PCFPER TABLE OPTB7NA4 FLAT CAP 161CM-1 Z ALLOWABLE LATERAL PASSIVE PRESSURE =150 PM 3. GROUT STRENGTH - 2000 PSI @ 28 DAYS. 4. RETAFORCNGSTEEL . GRADE 60, 5. 5EISMIC - 15EC. ACCELERATION a 70%. 6. 2000 PSI MASONRY COMPRESSION STRENGTH. ORCO 6816, 6616, OR 6618 LALU NOTES: GROUTED ONLY @ VERT STEEL SPECUL JNSPECTTON NOTE: PROVIDE LEVEL LT SPECIAL IN5FECTI0N PER TMS 402-131ACI 530-13/ASCE 6-13 TABLE 3.1.2 OF THE MASONRY STEM PRIOR TO GROUTING TO VERIFY GRADE, SIZE AND PROPER PLACEMENT OF RQNFORCE MEDVT AND TO ENSURE THE GROUT SPACE IS THE PROPER SIZE WITHOUT OBSTRUCTION 07HER THAN NORMAL MORTAR FINS. o� DROP -IN BAR @32"0/C. PROVIDE 24"LAP INTO 8' CMU. F6STDJOINT REINFORCEMENT 24" O/C (3 PLACES). USE I'5 M. FOR SLUMP BLOCK. NOTE.' PROVIDE #4 DOWEL N #4 DROP -IN SAR AT EACH SIDE OF CONTROL JOINTS, ENDS OF WALLS AND (A WALL HEIGHT CHANGF-S ,1'4 HORZ CON7 0 24" O/C LEVEL BACKFTLL W/GRANULAR B40CFTLL SOIL COMPACTED TO MIN. 90% RELATIVE COMPACTION PER A57N 1557-D. � C DOWEL �,— ® EDGE OF8" CMU 2'Q.0L �•y I I �w- 40Da SOR 35 PE RF PIPE W/ I OF. 314"GRAVEL WRAPPED EA W/MIC-S FABRIC -SLOPE 7D OPE ODU DRAIN. WATERPROOF B4OWDEOF RETAINING WALL. 1. CONCRETE BLOCK SHALL CONFORM TO ASTM C 90. ORCO STD, FREOSLOV, SPLIT FACF, OR SLUMP BLOCK MAY BE USED. Z CONCRETE FOR F0077NG SHALL BE I PART CEMENT TO 2-112 PARTS SAND TO 3-112 PARTS GRAVEL WITHA MAXIMUM OF 1-1/2 G4LLONS OF WATER PER SACK. PORTLAND CENUffSHALL CONFORM TO ASIM C 150 TYPEIl/V. FC - 2500 PST 3. RENFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTMA 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. RaW SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICHIFISLOCATED. 5. CONCRETE BLOCKSTNLL BE DYED IN A STACK BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL BLOCK CELLS CONTAINING VER77CAL RE94R SHALL BE SOLID GROUTED. 7, USE OSP TYPES MORTAR PROPOR77ONED USING ASTM C270. 1 PART CEMENT 70 412 PART LIME TO 4.1/2 PARTS O4MP, LOOSE SAND. B GROUT FOR CONCRETE BLOCK TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAYCONTAIN2 PARTS 3/8"PF4 GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BEADDED TO PRODUCE GOOD GROUT PLOW W THOUT SEGREGATION OF THE CONZWENTS PER ASTM 476. 9. BLOCTCSTEM MAY BE WET -SET 1-1/2"INTO THE F0077NG WHILE THE CONCRETE IS PUMC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TWVCL TYPE FOOTING. 10. F007ING MUST BE POURED ON OR INTO LWDISIURBE3D NATURAL SOIL OR ON COMPACTED FILL WITHA MINIMUM COMPACTION OF 90%. 11. FIRSF INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR COWUMANDAll. REQUIRED 57M IS TIED IN PUCE. SECOND INSPECT70N TO BE WHEN THE REQUIRED VERTICAL IS IN PLACEAND THE BLOCK WALL IS READY TO GROUP 12. MAXIMUM CONTROL JOINFSPACNG; 40' Q? OR 20' 01CIFTHE WALLIS TO BE STUCCO COATED, I 04 HORZ. CONT. @ 12' 0/C TOPAND BOTTOM AS SHOWN N4 KEY DOWEL @ 32" O/C ]' IN 34"AND HIGHER 12" 12" NOTE. DIMENSIONS ARE NOT TO SCALE. 'A' 'B' 'C I DOWEL 'K' 2'-0" 2'-3' #4032' 0/C�33" 5" 2l' 2'-8' 2'-6" ti9,32' 01CJ4/. I 9' 2'-9" #t4616' 0/C I49' J l3• 27• 4'-0" 3'-D" #4016' 0/C I57` J l8" 30, 2 5,1" MIN, CLEAR CELL OPEN REQUIRED TO USE 6616 SLUMPED C NU. Ly = ORCO WDE CELL SLUMP ENGINEERING STAMP APPROVAL IS CONDITIONAL; REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS. P 4 rn CITY OF IA QUINTA * EXP. 03/31/2021 yt 54-080 AVENIDA OBREGON s �v LA QLIINTA, CALMORNM ��TP C ! V 1 OF ce�� Project Name/Number : city of la qu ORCO Block & Hardscape Title City pf La Ouinta Page: 1 11100 Beach Blvd Dsgnr: GV Date: 8 OCT 2019 Stanton, CA 90680 Description.... Tel. (714) 527-2239 (01a) 6' wall w/2'-0" retaining This Wall in File: &ive - orco block corn Project files ReWInPra cj 1t387.201.a, 9utld 11.18,11.29 License : .OM9401 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13 License To: ORCO BLOCK COMPANY, INC, Criteria Retained Height = 2.00 ft Wall height above soil _��i% 6.00 ft Slope Behind Wall 0.00 Height of Soil over Toe 6.00 in Water height over heel 0.0 ft Surcharge Loads Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overtuming Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning Axial Load Applied to Stem I Axial Dead Load - 0.0 Ibs Axial Live Load _ 0.0 Ibs Axial Load Eccentricity = 0.0 in Design Summa Wall Stability Ratios Overturning - 1.68 OK Sliding _ 1.57 OK Total Bearing Load = 899 Ibs ...resultant ecc. = 6.46 in Soil Pressure @ Toe = 1,022 psf OK Soil Pressure ® Heel = 0 psf OK Allowable = 2,000 psf Soil Pressure Less Than Allowable ACI Factored ® Toe _ 1,431 psf ACI Factored ® Heel - 0 psf Footing Shear @ Toe = 6.8 psi OK Footing Shear @ Heel = 1.4 psi OK Allowable 75.0 psi Sliding Calcs Lateral Sliding Force _ 298.61bs less 100% Passive Force = - 200.5 Ibs less 100% Friction Force = = 269.7 Ibs Added Force Req'd - 0.0 Ibs OK ....for 1.5 Stability _ 0.0 Ibs OK Soil Data i Allow Soil Bearing = 2,000.0 psf Equivalent Fluid Pressure Method Active Heel Pressure = 45.0 psf/ft Passive Pressure 150.0 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingilSoil Friction = 0.300 Soil height to ignore for passive pressure = 12.00 in Lateral Load Applied to Stem Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom = 0.00 ft Load Type = Wind (W) (Strength Level) Wind on Exposed Stem = 26.7 psf (Strength Level) Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing s r ;4. Adjacent Adjacent Footing Load Adjacent Footing Load = 0.0lbs Fooling Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Fooling Type Line Load Base Above/Below Soll _ - 0.0 ft at Back of Wall Poisson's Ratio = 0.300 Stem Construction 2nd Bottom Stem OK Stem OK Design Height Above Ftg ft= 2.00 0.00 Wall Material Above "Ht" = Masonry Masonry Design Method = LRFD LRFD Thickness = 6.00 &00 Reber Size = # 4 # 4 Reber Spacing = 32.00 32.00 Rebar Placed at = Center Edge Design Data -- fb/FB + fa/Fa 0.543 0.518 Total Force @ Section Service Level Ibs = Strength Level Ibs = 160.2 304.2 Moment.... Actual Service Level ft-# = Strength Level ft-# = 480.6 897.0 Moment..... Allowable ft-# = 884.2 1,727.9 Shear...,.Actual Service Level psi = Strength Level psi = 9.1 3.3 Shear..... Allowable psi = 80.5 80.5 Anet (Masonry) in2 = 17.53 91.50 Reber Depth 'd' In = 2.75 5.25 Masonry Data f'm psi = 2,000 2,000 Fy psi = 60,000 60,000 Solid Grouting - No Yes Modular Ratio 'n' - 16.11 16.11 Wall Weight psf = 42.0 78.0 Load Factors --..__.. .__ :.. _:_ :..: __ ...... Building Code CBC 2016,AC1 Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 Equiv. Solid Thick. in = 3.90 7.60 eR°r Es$ / OHS ' 4 Masonry Block Type = Medium Weight A", 4RDUGo { Masonry Design Method = LRFD fi, Concrete Data +•' - J- f'c psi = w o M I J:�', Fy psi = NO. 03660 * E%P, 03/31/2021 * .I �qr Cl1� 4w V 0 F Op _CA`\F0 ORCO Block & Hardscape 11100 Beach Blvd Stanton, CA 90680 Tel. (714) 527-2239 This Wall in File: Project Name/Number : city of la qu Title City of La Quinta Page : 2 Dsgnr: GV Date: 8 OCT 2019 Description.... (01a) 6' wall w/2'-0" retaining - orco block companyWocumentslretainpro project fifes rssaunrm tcl ianr-xuze, BUM Tl.15.77.Z" Ucanise c KW-ON594M Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13 License To : ORCO BLOCK COMPANY, INC. Footing Dimensions & Strengths Too Width = 1.58 tt Heel Width = 0.67 Total Footing Width _ = 2.25 Footing Thickness = 12.00 in Key Width = 12.00 In Key Depth = 5.00 in Key Distance from Toe = 1.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0014 Cover 0 Top 2.00 @ Btm;= 3.00 in Footing Design Results Toe Heel Factored Pressure = 1,431 0 psf Mu': Upward - 1,255 0 ft-# Mu': Downward = 378 0 ft-# Mu: Design = 878 0 ft-# Actual 1-Way Shear = 6.80 1.40 psi Allow 1-Way Shear = 40.00 40.00 psi Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Other Acceptable Sizes & Spacings Toe: Not req'd: Mu < phi'5'lambda'sgrt(f'c)'Sm Heel: Not req'd: Mu < phi'5"lambda`sgrt(f'c)'Sm Key: Not req'd: Mu < phi'5'lambda'sgrt(f'c)"Sm Min footing T&S reinf Area 0.45 in2 Min footing T&S reinf Area per foot 0.20 in2 /ft If one layer of horizontal bars: If two layers of horizontal bars: #4® 11.90 In #4@ 23.81 in #5® 18.45 in #5® 36.90 in #6® 26.19 in #6® 52.38 in Surnmary of Overtuminq & Resisting Forces & Moments OVERTURNING..... .....RESISTING,.... Force Distance Moment Force Distance Moment Item Ibs ft ft-# Ibs ft ft-4 Heel Active Pressure = 202.5 1.00 202.5 Soil Over Heel = 2.25 Surcharge over Heel = Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem = Load 0 Stem Above Soil = 96.1 6.00 576.7 ` Axial Live Load on Stem = = Soil Over Toe = 91.0 0.79 72.0 Surcharge Over Toe = Total 298.6 O.T.M. 779.2 Stem Weight(s) = 408.0 1.86 760.9 Earth ® Stem Transitions = Footing Weight = 337.5 1.12 379.6 Resisting/Overturning Ratio = 1.68 Key Weight = 62.5 1.50 93.8 Vertical Loads used for Soil Pressure = 899.0 Ibs Vert. Component = Total = 899.0 Ibs R.M.= 1,306.2 ' Axial live load NOT included in total displayed or used for overturning resistance, but is included for soil pressure calculatior) Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Tilt m ` Horizontal Deflection, at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci cR°rt ss+o�4. Horizontal Defl @ Top of Wall (approximate only) 0.101 in3�ROU�o y TIlf3_ 17 VAT �.,.91,4 1uWion is nQ vlid iI the heel soil o excaed& Ihal.ol lhe,�, ,o y •' Lsec suss the wall would then tend �a ro[ale info fire sektined go sail, / v N0, 83660 b r •, * EXP 03/31/2021 * �p �rQrf aF CAL4 t•4¢� Project Name/Number : city of Is qu ORCO Block & Hardscape Title City pf La Quints Page: 1 11100 Beach Blvd Dsgnr: GV Date: 8 OCT 2019 Stanton, CA 90680 Description.... Tel. (714) 527-2239 (01 b) 6' wall w/2'-8" retaining This Wall in File: License: - orco block company\documents\retainpro project files Criteria Retained Height = 2.67 ft Wall height above soil = 6.00 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 6.00 in Water helght over heel = 0.0 ft Surcharge Loads Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning _.NI ILAxial Load Applied to Stern Axial Dead Load = 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Design Sumrrlar Wall Stability Ratios Overluming = 1.69 OK Sliding 1.55 OK Total Bearing Load = 1,053 Ibs ...resultant ecc. a 7.04 in Soil Pressure @ Toe = 1,059 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 1,483 psf ACI Factored @ Heel = 0 psf Footing Shear ® Toe = 8.1 psi OK Footing Shear @ Heel = 1.4 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 399.2 Ibs less 100% Passive Force = - 304.7 Ibs less 100% Friction Force = - 315.9 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 Stability = 0.0 Ibs OK Cantilevered Retaining Wall Soil Data 1 Allow Soil Bearing = 2,000.0 psf Equivalent Fluid Pressure Method Active Heel Pressure = 45.0 psf/ft Passive Pressure 150.0 psf/ft Soil Density, Heel 115.00 pcf Soil Density, Toe =. 115.00 pcf FootingIlSoil Friction 0.300 Soil height to ignore for passive pressure 12.00 in Lateral Load Applied to Stem Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom = 0.00 ft Load Type = Wind (W) (Strength Level) Wind on Exposed Stem = 26.7 psf (Strength Level) Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing Load Factors Building Code CBC 2016,AC1 Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 Code: CBC 2016,ACI 318-14,ACI 530-13 Adjacent Footing Load � jacent Footing oa = 0.0 Ihs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Line Load Base Above/Below Soil _ at Back of Wall - 0.0 ft Poisson's Ratio = 0.300 Stem Construction 2nd Bottom - Stem OK Stem OK Design Height Above Ftg ft= 2.67 0.00 Wall Material Above "Ht" = Masonry Masonry Design Method = LRFD LRFD Thickness = 6.00 8.00 Rebar Size = # 4 # 4 Reber Spacing = 32.00 32.00 Reber Placed at = Center Edge Design Data fb/FB + fa/Fa 0.543 0.657 Total Force ® Section Service Level Ibs = Strength Level Ibs = 160.2 416.8 Moment....Actual Service Level ft-#= Strength Level ft-# = 480.6 1,136.7 Moment..:.. Allowable ft-#= 884.2 1,727.9 Shear..... Actual Service Level psi = Strength Level psi = 9.1 4.6 Shea r.....Allowable psi = 80.5 60.5 Anet (Masonry) in2 = 17.53 91.50 Rebar Depth 'd' 1n = 2.75 5.25 Masonry Data f'm psi = 2,000 2,000 Fy psi = 60,000 60,000 Solid Grouting - No Yes Modular Ratio'n' = 16.11 16.11 Wall Weight psf = 42.0 78.0 Equiv. Solid Thick. in = 3.90 7.60 Masonry Block Type = Medium Weight Masonry Design Method = LRFD Concrete Data Pc psi = Fy psi = •QROFESS+d�`'•� a �c w¢w yy�gOl/r;O Ff � N NO, 83660 * EXP.03/31/2021 ��rE OF LP 0Q�/, Project Name/Number : city of Is qu ORCO Block & Hardscape Title City of La Quints Page: 2 11100 Beach Blvd Dsgnr: GV Date: 8 OCT 2019 Stanton, CA 90680 Description.... Tel. (714) 527-2239 (01b) 6' wall w/2'-8" retaining This Wall in File: - orco block companyWocumentsVelainpro project files rirfgtnPrD [Cy 18s7�416, euilu 11.la.11.te License: KW.06"01 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13 License To: ORCO BLOCK COMPANY, INC. Footing Dimensions & Strengths Toe Width = 1.83 ft Heel Width = _ 0.67 Total Footing Width = 2.50 Footing Thickness = 12.00 in Key Width = 12.00In Key Depth = 9.00 in Key Distance from Toe = 1.00 It f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0014 Cover ® Top 2.00 ® Btm;= 3.00 in Footing design Results I Toe Heel Factored Pressure = 1,483 0 psf Mu': Upward = 1,725 0 ft-# Mu': Downward = 494 0 ft-# Mu: Design - 1,231 0 ft-# Actual 1-Way Shear = 8.06 1.40 psi Allow 1-Way Shear = 40.00 40.00 psi Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing None Spec'd Other Acceptable Sizes & Spacings Toe: Not req'd: Mu < phi'5'lambda'sgrt(f'c)'Sm Heel: Not req'd: Mu < phi'5`lambda'sgrt(f'c)"Sm Key: Not req'd: Mu < phi'5'lambda'sgrt(f'c)'Sm Min footing T&S reinf Area 0.50 in2 Min footing T&S feint Area per foot 0.20 in2 At If one layer of horizontal bars: If two layers of horizontal bars: #4@ 11.90 in #4® 23.81 in #5@ 18.45 in #5® 36.90 in #6® 26.19 in #6@ 52.38 in Summary of Overturning* Resisting Forces & Moments OVERTURNING..... .....RESISTING...., Force Distance Moment Force Distance Moment Item Ibs ft ft-# Ibs ft ft-# Heel Active Pressure = 303.1 1.22 370.7 Soil Over Heel = 2.50 Surcharge over Heel = Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem = Load ® Stem Above Soil = 96.1 6.67 641.1 ' Axial Live Load on Stem = _ Soil Over Toe = 105.4 0•92 96.6 Surcharge Over Toe = Total 399.2 O.T.M. 1,011.9 Stem Weight(s) = 460.3 2.12 976.1 Earth ® Stem Transitions= _ = Footing Welghi = 375.0 1.25 468.6 Resisting/Overturning Ratio = 1.69 Key Weight = 112.5 1.50 168.8 Vertical Loads used for Soil Pressure = 1,053.1 Ibs Vert. Component = Total = 1,053.1 Ibs R.M.= 1,710.0 ' Axial live load NOT included in total displayed or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Tilt Horixn tal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl ® Top of Wall (approximate only) 0.102 in The abave cuict.11allon is not valid II the heel soli bepring piessyrp e? s 1hat of iha oa beq@use the wall would than tenO to inlate Into 11hetrglaingo W.I. v ass a R m m a A' NO. 63660 * EXP 03/3UZ021 y srgT C` I V I �� a F Fe i OF CA0 Project Name/Number : city of Is qu ORCO Block & Hardscape Title City of La Quints Page: 1 11100 Beach Blvd Dsgnr: GV Date: 8 OCT 2019 Stanton, CA 90680 Description.... Tel. (714) 527-2239 (01c) 6' wall w/3'-4" retaining This Wall in File: 0userslgverdugolonedrive - orco block License: KW-MS94M '''$'tim Cantilevered Retaining Wall License To: ORCO BLOCK COMPANY. INC. Criteria Retained Height = 3.33 ft Wall height above soil = 6.00 ft Slope Behind Wall _ 0.00 Height of Soil over Toe 6.00 In Water height over heel 0.0 ft Surcharge Loads Surcharge Over Heel = 0,0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning Axia! load A lied to Stem Axial Dead Load = 0.0lbs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Design Summary Wall Stability Ratlos Overturning = 1.64 OK Sliding = 1.52 OK Total Bearing Load 1,206 Ibs ...resultant ecc. = 8.17 in Soil Pressure ® Toe = 1,158 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 1,622 psf ACI Factored @ Heel = 0 psi Footing Shear @ Toe = 9.4 psi OK Footing Shear @ Heel = 1.4 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 518.0 Ibs less 100% Passive Force = - 425.5 Ibs less 100% Friction Force = - 361.9 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 Stability = 0.0 Ibs OK tiles Soil Data J Aliaw Soil Bearing = 2,000.0 psf Equivalent Fluid Pressure Method Active Heel Pressure = 45.0 psf/ft Passive Pressure = 150.0 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingliSoil Friction = 0.300 Soil height to ignore for passive pressure = 12,00 in Lateral Load Applied to Stem Lateral Load = 0.0 #/it -Height to Top = 0.00 it ...Height to Bottom = 0.00 ft Load Type = Wind (W) (Strength Level) Wind on Exposed Stem = 26.7 psf (Strength Level) Vertical component of active lateral soil pressure IS NOT considered In the calculation of soil bearing Load Factors - - Building Code CBC 2016,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1:000 Code: CBC 2016,ACI 318-14,ACI 530-13 I� i Adjacent Footing Load Adjacent Footing Load 0.0Ibs Footing Width = 0.00 ft Eccentricity = O.00In Wall to Ftg CL Dist = 0.00 It Footing Type Line Load Base Above/Below Soil at Back of Wall 0 0 ft Poisson's Ratio Stem Construction Aend Bottom _....... Stem OK Stem OK Design Height Above Ftc ft= 3.33 0.00 Wall Material Above "Ht" = Masonry Masonry Design Method = LRFD LRFD Thickness = 6.00 8.00 Rebar Size = # 4 # 4 Rebar Spacing = 32.00 16.00 Rebar Placed at = Center Edge Design Data fb/FB + fa/Fa _ 0.543 0.432 Total Force @ Section Service Level Ibs = Strength Level Ibs = 160.2 559.4 Moment.... Actual Service Level ft-# = Strength Level ft-#= 480.6 1,457.2 Moment. -...Allowable ft-# = 884.2 3,368.0 Shear..... Actual Service Level psi = Strength Level psi = 9.1 6.1 Shear..... Allowable psi = 80.5 80.5 Anet (Masonry) in2 = 17.53 91.50 Rebar Depth 'd' In = 2.75 5.25 Masonry Data - - f'm psi = 2,000 2,000 Fy psi = 60,000 60,000 Solid Grouting = No Yes Modular Ratio 'n' - 16.11 16.11 Wall Weight psf = 42.0 78.0 Equiv. Solid Thick. in = 3.90 7.60 PgpF Ess r ohs , Masonry Block Type = Medium Weight 4ti° yE�cL'co i Masonry Design Method = LRFD ti� :rry ' m p - Concrete Data - 05 r� m, m f'c psi = o A Fy psi = NO. 63660 ' * EXP, 03/31/2021 * ;� 1 T C I V rP c OF CA0 Project Name/Number : city of la qu ORCO Block & Hardscape Title City Of La Oulnts Page: 2 11100 Beach Blvd Dsgnr: GV Date: 8 OCT 2019 Stanton, CA 90680 Description.... Tel. (714) 527-2239 (01c) 6' wall w/3'-4" retaining This Wall in File: c:luserslgverdug6onedrlve - orco block companyldocumentsVetainpro project flies RetainPra (s)1987.2018, Build 11.18.11.29 Ucansa: KW-06059401 License To : ORCO 19LOCK COMPANY INC. Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13 Footing Dimensions & Strengths Footing Design Results Toe Width _ 2.08 ft Toe Heel Heel Wldth = 0.67 Factored Pressure = 1,622 0 psf Total Footing Width = 2.75 Mu': Upward = 2.346 0 ft-# Footing Thickness 12.00 in Mu': Downward = 627 0 ft-# Mu: Design = 1,719 Oft-# Key Width = 12.00 in Actual 1-Way Shear = 9.35 1.40 psi Key Depth = 13.00 in Allow 1-Way Shear = 40.00 40.00 psi Key Distance from Toe = 1.00 ft Toe Reinforcing = None Spec'd f c = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density = 150.00 pef Key Reinforcing = None Spec'd Min. As % 0.0014 Other Acceptable Sizes & Spacings Cover 0 Top 2.00 ® Btm.== 3.00 in Toe: Not req'd: Mu < phi"5'lambda"sgrt(f'c)"Sm Heel: Not req'd: Mu < phi"5"lambda"sgrt(f'c)"Sm Key: Not req'd: Mu < phi"5'lambda"sgrt(f'c)"Sm Min footing T&S reinf Area Min footing T&S reinf Area per foot If one layer of horizontal bars: #4@ 11.90 in #5@ 18.45 in #6® 26.19 in 0.55 in2 0.20 in2 /it If two layers of horizontal bars: #4@ 23.81 in #5@ 36.90 in #6@ 52.38 in Summary of Overturning & Resisting Forces & Moments ..OVERTURNING..... RESISTING...,. Force Distance imament Force Distance Moment Item Ibs ft ft-# Ibs ft ft-# Heel Active Pressure = 421.9 1.44 608.9 Soil Over Heel = 2.75 Surcharge over Heel = Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem = Load ® Stem Above Soil = 96.1 7.33 704.6 " Axial Live Load on Stem = Soil Over Toe = 119.8 1.04 124.7 Surcharge Over Toe = Total 518.0 O.T.M. 1,313.4 Stem Weight(s) = 511.7 2.38 1,215.5 Earth 0 Stem Transitions= _ = Footing Weighl = 412.5 1.37 567.1 Resisting/Overturning Ratio = 1.64 Key Weight = 162.5 1.50 243.8 Vertical Loads used for Soil Pressure = 1,206.5 Ibs Vert. Component = Total = 1,206.5 Ibs R.M.= 2,151.1 Axial Ilve load NOT included in total displayed or used for overturning resislance, bul is included for soil pressure calculation. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Tap of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl 0 Top of Wall (approximate only) 0.109 in 1'he actve ealcuialion is rtDI valid it lf}E_heal soli tleArlfx] nrp /roext:ew#hat ajj tt>Ifs toe, l7eCdusB It1e wall wpgfd Lhen_len(I 10 Fotale irk-)l1p rel- flgM :� e�ssrati�-•.� I0_RD1/G0 ti ❑ � it No, 83660 n� * EXP. 03/31/2021 * �' qr c r v i 1. QQ6+ : E Ot- CA-01 Project Name/Number : city of la qu ORCO Block & Hardscape Title City 9f La Ouinta Page : 1 11100 Beach Blvd Dsgnr: GV Date: 6 OCT 2019 Stanton, CA 90680 Description.... Tel. (714) 527-2239 (Old) 6' wall w/4'-0" retaining This Wall in File: c:luserslgverdugolonedrlve - orco block ccmpanyldocumentsVetalnpro project files rleiainrro tc1 ivar;eura, nunaii.in.ii.zv License : KW-06059401 License To: ORCO BLOCK COMPANY, INC. Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13 Criteria _ Soil Data j- Retained Height 4.00 ft Allow Soil Bearing = 2,000.0 psf I I Wall height above soil 6.00 ft Equivalent Fluid Pressure Method I Active Heel Pressure - 45.0 psf/ft Slope Behind Wall - 0.00 Height of Soil over Toe 6.00 In = Water height over heel = 0.0 ft Passive Pressure = 150.0 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoll Friction = 0.300 Soil height to ignore for passive pressure = 12.00 in j Surcharge Loads Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overtuming Surcharge Over Toe = 0.0 psf Used for Sliding & Overtuming Axial Load Applied to Stem Axial Dead Load = 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Debi n Summary Wall Stability Ratios Overturning 1.55 OK Sliding = 1.54 OK Total Bearing Load =, 1,373 Ibs ...resultant ecc. a 9.74 In Soil Pressure @ Toe = 1,330 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 1,862 psf ACI Factored ® Heel = 0 psf Footing Shear @ Toe = 10.7 psi OK Footing Shear ® Heel = 1 A psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 658.6 Ibs less 100% Passive Force = - 600.0 Ibs less 100% Friction Force = - 411-9 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 Stability = 0.0 Ibs OK Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing Building Code CBC 2016,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 Lateral Load Applied to Stem Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom = 0.00 ft Load Type = Wind (W) (Strength Level) Wind on Exposed Stem = 26.7 psf (Strength Level) Stern Construction 2nd - - Stem OK Design Height Above Ftg ft= 4.00 Wall Material Above "Ht" = Masonry Design Method = LRFD Thickness = 6.00 Rebar Size = # 4 Rebar Spacing = 32.00 Rebar Placed at = Center Design Data fb/FB + fa/Fa a 0.543 Total Force @ Section Service Level Ibs = Strength Level Ibs = 160.2 Moment.... Actual Service Level ft-# = Strength Level ft-# = 480.6 Moment..... Allowable ft-#= 884.2 Shear..... Actual Service Level psi = Strength Level psf = 9.1 Shear..... Allowable psi = 80.5 Anet (Masonry) in2 = 17:53 Reber Depth 'd' in = 2.75 Adjacent Footing load Adjacent Footing Load = 0.01bs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Line Load Base Above/Below Soil at Back of Wall ' 0.0 ft Poisson's Ratio = 0.300 Bottom Stem OK 0.00 Masonry LRFD 8.00 # 4 16.00 Edge 0.560 736.2 1,889.4 3,368.0 8.0 80.5 91.50 5.25 Masonry Data --- --- __ _ .__,- _...,. f'm psi = 2,000 2,000 Fy psf = 60,000 60.000 Solid Grouting No Yes Modular Ratio 'n' a 16.11 16.11 Wall Weight psi = 42.0 78.0 Equiv. Solid Thick. In = 3.90 7.60 Masonry Block Type = Medium Weight Masonry Design Method = LRFD Concrete Data f'c psi = Fy psi 4 4ROFf ss 1OH4[ �r�, d�R QUO'Ot y NO.63660 A * E%P, 03/31/2021 F OF CA09 0,. Project Name/Number: city of Is qu ORCO Block & Hardscape Title City of Le Quints Page : 2 11100 Beach Blvd Dsgnr: GV Date: 8 OCT 2019 Stanton, CA 90680 Description.... Tel. (714) 527-2239 (01d) 6' wall w/4'-0" retaining This Wall in File: c;luserslgverdugftnedrive - orco block companyldocumentslretainpro project fleas License XW-IM594Q1' . Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13 License To; ORCO BLOCK COMPANY, INC. Footing Dimensions & Strengths Toe Width = 2.33 ft Heel Width = 0.67 Total Footing Width = 3.00 Footing Thickness = 12.00 in Key Width = 12.00 in Key Depth = 18.00 in Key Distance from Toe = 1.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % I Pf 0,0014 Cover @ Top 2.00 @ Btm;-- 3.00 in Footing Design Results Toe Heel Factored Pressure = 1,862 0 psf Mu': Upward - 3.162 0 ft-# Mu': Downward 774 0 ft-# Mu: Design - 2,387 0 ft-# Actual 1-Way Shear = 10.73 1.40 psi Allow 1-Way Shear = 40.00 40.00 psl Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Other Acceptable Sizes & Spacings Toe: Not req'd: Mu < phi'5'lambda'sgrt(f'c)'Sm Heel: Not req'd: Mu < phi'5'lambda"sgrt(f'c)'Sm Key: Not req'd: Mu < phi'5'lambda'sgrt(f'c)'Sm Min footing T&S reinf Area 0.60 in2 Min footing T&S reinf Area per foot 0.20 in2 ift If one layer of horizontal bars: If two layers of horizontal bars: #4@ 11.90 In #4@ 23.81 in #5@ 18.45 in #50 36.90 in #6@ 26.19 in #6® 52.38 in Summary of Overturning & Resisting Forces & Moments .,_OVERTURNING..... .....RESISTING..... Force Distance Moment Force Distance Moment Item Ibs ft ft-# Ibs ft ft-# Heel Active Pressure = 562.5 1.67 937.5 Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 96.1 8.00 769.0 Total 658.6 O.T.M. 1,706.5 Resisting/Overturning Ratio - 1.55 Vertical Loads used for Soil Pressure = 1,373,1 Ibs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Soil Over Heel = 3.00 Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = - Axial Live Load on Stem = Soil Over Toe = 134.1 1.17 156.5 Surcharge Over Toe = Stem Weight(s) = 564.0 2.63 1,482:8 Earth @ Stem Transitions = Footing Weighl = 450.0 1.50 674.9 Key Weight = 225.0 1.50 337.5 Vert. Component = Total = 1,373.1 Ibs R.M.= 2,651.6 ' Axial live load NOT included in total displayed or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Too of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.123 in The alxavc raiti+latron rs 1,101 vjrlrr,i rf file b0cal sail hiannrz r rcrss eNC:-ls IhRI al ih. 9, because the wall would then tend to rotate into the retained soil. �aflrtessro� 4 lyR`�4 Iell 0t1g0` f ` j u' m• m m NO 83660 . f ' * EXP. 03/31/2021 * Jr sq '� CIV t�'�; a•;J TF OF ORCO 6' HIGH WALL W/ 2'--0" - 4'--0" RETAINING FOR 110 MPH WIND 3 SEC. GUST @a EXP C $'PL:�G[AL rM5PEG7UOAf NOTE: OM45 u CRrrEau PER 20rs LL7c PROVIDE LEVEL B SPECIAL IN5PEMON PER TINS 401-13/ACI530-131ASCE 6-13 TABLE 3.1.2 1. SOIL BEARING PRESSURE -1500 PSF+ 0 INCR. FOR WIND �LPTIL1111LfLiTLAa OF THE MASONRY57EM PRIOR TO GROU77NG OR SEISMIC EQUNALENT RUID PRESSURE =45 PCF PER TABLE TO VERIFY GRADE, SIZE AND PROPER 16104-1 PLACEMENT OF REINFORCEMENT AND TO 2 ALLOWABLE LATERAL PASSIVE PRESSURE -150 PCF. J. STRENGTH ENSURE THE GROUT SPACE IS THE PROPER REINR71Pf1EINFONG57EEL 2000 PSI 28 DAYS, �. 0 : GRADE60. SIZE WITHOUT OBSTRUCTION OTHER THAN S. SEISMIC - I SEC. ACMERATTON = 70%. IVORMAL MORTAR FINS. 6. 2000 PSI MASONRY COMPRESSION STRENCRf NOTES: ORCO 6814 6616 OR 6618 OMU GROUTED ONLY 6 MTSTM /4 VERT DROP -IN BAR 0 32" O/C PROWDE 24"LAP INTO 8"OMU. 06 57D JOMT PFI NFCRCEA FNT OF 24" O/C (3 MA03)• LISE 05 STD. FOR SLUMPBLOOI. 11 NOTE• PROVIDE #4 DOWEL & 04 DROP IN BAR AT EACH SIDE OF CONTROL JOINTS, ENDS OF WALLSAND &D WALL HEIGHT CNANG"S LEVEL B400L. W/GRANULAR BA0O.7LL SOIL COMPACTED TO MIN. 901% RELA77VE COMPACTION PER A5/74 1557-D. 04 NQPZ L17NT. 024' 01C — I lid= CDDWEL V EDGEOFe"m 2 RR 4" DIA, SOR 35 PERFPIPE W/ _ 1 CF. 3V4"GRAVEL WRAPPED W/MIRAFII401YFILTER !�•.• 7, "'—I FABRIC -SLOPE TO DRAIN. WATERPWALL S/DEOF RETUNING U'Itau 04 NLV1Z. CONE . ` V 12ffQC 12' NOTE: DIMENSIONS ARE NOT TO SCALE.J 'A' 'B' 'C' DOWEL I 'D' BAR V 2'-0" 2'-9" #4®32" O/C .133' 04@32' O/C 27' N/A 12' �""-. 6' F-- 2'-8" Z'-9" iR4®3Z' O/C 4/' L 040,52, O/C 4 l2" 6' F 1r4016' 01C 40, #4@16' O/C 30" 6• 12" 6' F 4'-0" #406. 0/C. � 57- 04@16" 0/C 3' 9' 2 6' 1. CONCRETEBLOOYSHALL CONFORM TOASIMC90. ORCOSTD. PRECISION, SPLIT FA OR SLUMP &OCK MAY BE USED. Z CONCRETE FOR FOOTING 94ALL BE 1 PART CEMENT TO 1-112 PARTS SAND 70 3-V2 PARTS GRAVEL W17H A MAXIMUM OF 1-112 GALLOWS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE B/V. Fr - 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTMA 615 GRADE 60. PROVIDE 48 BAR DIAMETER LIP. 4. REBAR SHALL BE CENTERED IN THE CONO7ETE BLOCK CELL IN WHICH IT IS LOC4TED. S. CONCRETE &OCKSHALLBELA*VINASTACKBOND PATTERN WITH VER77CAL CONT77VU17YOF7HECELLS UNO. 6. ALL BLOCK CELLS CONTATNING VER77CAL REBAR SHALL BE SOLID GROUTED. 7. USE OBPTYPE SMORTAR PROPORTIONED USBNGASTMC270. 1 PART CEMENT TO 1/2 PART LIME TO 4.112 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK TO BE I PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL JF WEATHER CONDITIONS ARE FAVORABLE AND BLOOM UNOBSTRUCTED CELL WE IS SUFFICIENT TOALLOW GOOD GROUT ROW). WATER SHALL BEADDED TO PRODUCE GOOD GROUT ROW WITHOUT SEGREGATTON OF THE COAMMENTS PER ASIM 476. 9. BLOCKSTEM MAYBEWET-SET1412"INTOTHE F007INGWHILE THECONCRETt: IS PLASTIC BLOCKSTEM MAYBEPLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO LNDLSTURBED NATURAL SOIL OR ONCOMPACTED FILL WI/NA MINIMUM COMPACTION OF 90%. 11. FIRSrRV5FEM0NTOBEAPTER FOOTING TRENCHESARE READY FOR CONC.RETEAND ALL REQUhRED STEEL !S TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE RE(ti' 6RLD VER77C4L ISIN FLACEAND THE BLOCK WALL IS READY TO GROUT. I Z MAXIMUM CONTROL XWVT SPACING 40' O/C OR 20' O/CIF THE WALL IS TO BE STUCCO CO4TED. ,2518"MIMCLIAR CELL OPEN REQUIRED TO USE 6616 SLUMPED CMU. ORCO WIDE CELL SLUMP ENGINEERING STAMPAPPROVALISCONDMOMG; REQUIRINO USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS. �1 Carr of LA QUZNTA IN 54-060 AVENIDA OBREGON LA QUIN TA, C4LMORNIA /. 'Q -DU6O •c La m NO. 83660 * EXP, 03/51/2021 4 s9r C I V F OF Cp4.�F 0 Project Name/Number : city of Is qu ORCO Block & Hardscape Title City of La Quints Page : 1 11100 Beach Blvd Dsgnr: GV Date: 8 OCT 2019 Stanton, CA 90680 Description.... Tel. (714) 527-2239 (02a) 6' wall w/T-0" retaining This Wall in File: - orco block companMDcumentsVetalnpro project files License; KW-08039401 License To : ORCO BLOCK COMPANY, INC. Criteria j Retained Height = 2.00 ft Wall height above soil 6.00 It Slope Behind Wall = 0.00 Height of Soil over Toe = 6.00 in Water height over heel 0.0 ft Surcharge Loads Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psi Used for Sliding & Overturning Axial Load Applied to Stem I Axial Dead Load = 0.0lbs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Design Summary J; Wall Stability Ratios Overturning a 1.93 OK Sliding a 1.62 OK Total Bearing Load 1,300 Ibs ...resultant ecc. 9.84 in Soil Pressure ® Toe = 1,561 psf OK Soil Pressure ® Heel = 0 psf OK Allowable = 2,000 psf Soil Pressure Less Than Allowable ACI Factored ® Toe = 2,185 psf ACI Factored @ Heel = 0 psf Footing Shear ® Toe = 10.7 psi OK Footing Shear ® Heel = 2.5 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 298.6 Ibs less 100% Passive Force = - 93.8 Ibs less 100% Friction Force = - 389.9 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 Stability = 0.0 Ibs OK Cantilevered Retaining Wall Soil Data , Allow Soil Bearing = 2,000.0 psf Equivalent Fluid Pressure Method Active Heel Pressure = 45.0 psf/ft Passive Pressure = 150.0 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.300 Soil height to ignore for passive pressure = 12.00 in Lateral Load Applied to Stem Lateral Load 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom = 0.00 ft Load Type = Wind (W) (Strength Level) Wind on Exposed Stem = 26.7 psf (Strength Level) Vertical component of active lateral soil pressure IS NOT considered In the calculation of soil bearing 1. _ G'*•7- 11111111 Code: CBC 2016,ACI 318-14,AC1 530-13 Adjacent Footing load Adjacent Footing Load 0.0 lbs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Line Load Base Above/Below Soil _ 0.0 ft at Back of Wall Poisson's Ratio = 0,300 Stem Construction J _ 2nd Bottom Stem OK Stem OK Design Height Above Ftg ft= 2.00 0.00 Wall Material Above "Ht" = Masonry Masonry Design Method = LRFD LRFD Thickness = 6.00 8.00 Reber Size = # 4 # 4 Reber Spacing = 32.00 32.00 Reber Placed at = Center Edge Design - fb/FB Total Force @ Section Service Level Ibs = Strength Level Ibs = 160.2 304.2 Moment.... Actual Service Level it-# = Strength Level ft-# = 480.6 897.0 Moment..... Allowable ft-#= 884.2 1,727.9 Shear..... Actual Service Level psi= Strength Level psi = 9.1 3.3 Shear..... Allowable psi = 80.5 80.5 Anet (Masonry) in2 = 17.53 91.50 Reber Depth 'd' 'In = 2.75 5.25 Masonry Data f'm psi = 2,000 2,000 Fy psi= 60,000 60,000 Solid Grouting - No Yes Modular Ratio 'n' 16.11 16.11 Wall Weight psf= 42.0 78.0 Building Code CBC 2016,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1=0 Equiv. Solid Thick. in= 3.90 7.60 pRDressr Nam. Masonry Block Type = Medium Weight mow° .4egDUGp rl Masonry Design Method = LRFD Concrete Data ft psi = w Q p m l Fy pst = NO, 83660 * EXP. 03/31/2021 * ,r OF CA0\ Project Name/Number : city of la qu ORCO Block & Hardscape Title City pf La Quinta Page: 2 11100 Beach Blvd Dsgnr: GV Date: 8 OCT 2019 Stanton, CA 90680 Description.... Tel. (714) 527-2239 (02a) 6' wall w/2'-0" retaining This Wall in File: cAusers\gverdugo\onedrive - orco block companyWocumentsVetainpro project files RelainPra (c) 7987.2018, Sulk! 11.10.11.29 License:K1N-06fSM1 License To. ORCO BLOCK COMPANY, INC. Cantilevered Retaining Wall Code: CBC 2016,AC1 318-14,ACI 530-13 _ Footing Dimensions & Strengths Footing Design Results Toe Width = 0.00 ft Toe Heal Heel Width = 2.75 Factored Pressure = 2,185 0 psf Total Footing Width = 2.75 Mu': Upward = 0 218 ft-# Footing Thickness 12.00 in Mu': Downward = 0 1,148 ft-# Mu: Design = 0 930 ft-# Key Width = 12.00 In Actual 1-Way Shear = 10.73 2.46 psi Key Depth = 0.00 in Allow 1-Way Shear = 40.00 40.00 psi Key Distance from Toe 1.50 ft Toe Reinforcing = None Spec'd f'c = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density = 150.00 pcf Key Reinforcing = None Specd Min. As % 0.0014 Other Acceptable Sizes & Spacings Cover @ Top 2.00 ® Btm = 3.00 in Toe: Not req'd: Mu < phi '5'lambda'sgrt(f'c)'Sm Heel: Not req'd: Mu < phi'5'lambda'sgrt(f'c)'Sm Key: No key defined Min footing T&S reinf Area Min footing T&S reinf Area per foot If one layer of horizontal bars: #4® 11.90 in #5@ 18.45 in #60 26.19 in of Overtuming & Resisting Forces & Moments Item Heel Active Pressure = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = Force Distance Moment Ibs it ft-# 202.5 1.00 202.5 96.1 6.00 576.7 Total 298.6 O.T.M. 779.2 Resisting/Overturning Ratio = 1.93 Vertical Loads used for Soil Pressure = 1,299.7 Ibs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. 0.55 in2 0.20 in2 /it If two layers of horizontal bars: #4® 23.81 in #5® 36.90 in #60 52.38 in Sal Over Heel = Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = ' Axial Live Load on Stem = Soil Over Toe = Surcharge Over Toe = Stem Weight(s) _ Earth ® Stem Transitions= Footing Weight = Key Weight = Vert. Component = .RESISTING..... Force Distance Moment Ibs It ft-# 479.2 1.71 818.6 408.0 0.28 115.0 412.5 1.38 567.2 2.00 Total = 1,299.7 Ibs R.M.= 1,500.8 Axial live load NOT Included in total displayed or used for overturning resistance, but is Included for soil pressure cajculation. Tilt Horizontal Deflection at Toga of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.126 in The ai}gv_e cak:ulakon is riot velid_i[ 111 hoB; sold ArInO_ruesstirre exceeds ttlaLof_lhe toy. !�ggcausy IhQwall muld then lei KJ lo totgte mloHer In 3 cr+ii. v�ypf ES IS . �g. r wow ��gRpU�O 4 a . • NO, 63660 D * EXP. 03/31/2021 sqr C/V E Oft tAL�fG Project Name/Number : city of la qu ORCO Block & Hardscape Title City of La Quinta Page: 1 11100 Beach Blvd Dsgnr: GV Date: 8 OCT 2019 Stanton, CA 90680 Description.... Tel. (714) 527-2239 (02b) 6' wall w/2'-8" retaining This Wall in File: (drive - orco block com project files R4ts1nPra (C)1W? 4018, aulid 11.18.11.29 Ucengs: KW-06059401 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13 License To t ORCO BLOCK COMPANY, INC. Criteria Retained Height = 2.67 ft Wall height above soil = 6.00 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 6.00 in Water height over heel = 0.0 It Surcharge Loads Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning Axial Load Applied to Stem f Axial Dead Load = 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Design Summary Wall Stability Ratios Overturning 1.88 OK Sliding LL 1.62 OK Total Bearing Load = 1562 Ibs ...resultant ecc. = 9.64 in Soil Pressure ® Toe = 1,822 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,551 psi ACI Factored ® Heel = 0 psf Footing Shear @ Toe = 10.7 psi OK Footing Shear @ Heel = 2.7 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 399.2 Ibs less 100% Passive Force = - 177.1 Ibs less 100% Friction Force = - 468.7 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 Stability = 0.0 Ibs OK Soil Data Allow Soil Bearing = 2,000.0 psf Equivalent Fluid Pressure Method Active Heel Pressure = 45.0 psf/ft Passive Pressure = 150.0 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.300 Soil height to Ignore for passive pressure = 12.00 in Lateral Load Applied to Stem Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom = 0.00 ft Load Type = Wind (W) (Strength Level) Wind on Exposed Stem = 26.7 psf (Strength Level) Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing Stem Construction s Design Height Above Ftg It = Wall Material Above "Ht" _ Design Method Thickness = Rebar Size = Reber Spacing Reber Placed at = Design Data - fb/FB + fa/Fa Total Force ® Section Service Level Ibs = Strength Level Ibs = Moment.... Actual Service Level ft-# _ Strength Level ft-# = Moment..... Allowable ft-# = Shear..... Actual Service Level psi= Strength Level psi= Shear..... Allowable psi = Anet (Masonry) in2 = Reber Depth 'd' In = Masonry Data I'm psi = Fy psi = Solid Grouting a Modular Ratio 'n' a Wall Weight psf= Load Factors _.._..._......_A ._ _.._..............._._..:. Building Code CBC 2016,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 2nd Stem OK 2.67 Masonry LRFD 6.00 # 4 32.00 Center 1._ Adjacent Footing Load Ad scent Footing Load = 0.0 lbs. Footing Width _ 0.00 ft Eccentricity _ 0.00 in Wall to Ftg CL Dist = 0.00 It Footing Type Line Load Base Above/Below Soil 0.0 ft at Back of Wall Poisson's Ratio - 0.300 Bottom Stem OK 0.00 Masonry LRFD 8.00 # 4 32.00 Edge 0.543 0.657 160.2 416.8 480.6 1,136.7 884.2 1,727.9 9.1 4.6 80.5 80.5 17.53 91.50 2.75 5.25 2,000 2,000 60,000 60,000 No Yes 16.11 16.11 42.0 78.0 Equiv. Solid Thick. in= 3.90 7.60 eR°vase �� Masonry Block Type = Medium Weight ¢w°• y�RnUGC Masonry Design Method = LRFD h� -z" Concrete Data rn f'c psi = w Q M , Fy psi c N0. 83660 n I * EXP. 03/31/2021 .. F OF CA,-' Project Name/Number : city of Is qu ORCO Block & Hardscape Title City of La Quints Page: 2 11100 Beach Blvd Dsgnr: GV Date: 8 OCT 2019 Stanton, CA 90680 Description.... Tel. (714) 527-2239 (02b) 6' wall w/2'-8" retaining This Wall in File: c:lusers%gverdugalom&ve - orco block companyLdocumenls)relainpro project files rseselnrra {sj �ae�-xuTn, Cu11R 77.lS.li.xJ t.lcenee: KW-M59401 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13 _License To. ORCO BLOCK COMPANY, INC. _ - Footing Dimensions & Strengths Footing Design Results Toe Width = 0.00 it Toe Heel Heel Width = 2..75 Factored Pressure = 2,551 0 psf Total Footing Width = 2.75 Mu': Upward = 0 2B5 ft-# Footing Thickness = 12.00 in Mu': Downward = 0 1,381 ft-# Mu: Design = 0 1,095 ft-# Key Width = 1in Actual 1-Way Shear = 10.73 2.71 psi Key Depth = 4.00 .00 In Allow 1-Way Shear = 40.00 40.00 psi Key Distance from Toe = 1.75 It Toe Reinforcing = None Spec'd rc = 2,500 psi Fy = 6o,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd Min. As % - 0.0014 Other Acceptable Sizes & Spacings Cover ® Top 2.00 @ Btm� 3.00 in Toe: Not req'd: Mu < phi"5'lambda"sgrt(f'c)"Sm Heel: Not req'd: Mu < phi"5`lambda`sgrt(f'c)"Sm Key: Not req'd: Mu < phi"5"lambda"sgrt(rc)`Sm Min footing T&S relnf Area 0.55 in2 Min footing T&S reinf Area per foot 0.20 in2 /it If one layer of horizontal bars: If two layers of horizontal bars: #4® 11.90 in #4@ 23.81 in #5@ 18.45 in #5® 36.90 in #6@ 26.19 in #6@ 52.38 in - - ........................ ......._- Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... .....RESISTING..... Force Distance Moment Force Distance Moment Item Ibs ft ft-# Ibs ft ft-# Heel Active Pressure = 303.1 1.22 _ 370.7 Soil Over Heel = 639.7 i.71 1,092.8 Surcharge over Heel = Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem = Load @ Stem Above Soil = 96.1 &67 641.1 ` Axial Live Load on Stem = = Soil Over Toe = Surcharge Over Toe = Total 399.2 O.T.M. 1,011.9 Stem Weight(s) = 460.3 0.29 132.4 Earth @ Stem Transitions= _ = Footing Weighs = 412.5 1.38 567.2 Resisting/Overturning Ratio = 1.88 Key Weight = 50.0 2.25 112.5 Vertical Loads used for Soil Pressure = 1,562.4 Ibs Vert. Component = Total = 1,562.4 Ibs R.M.= 1,904.9 ` Axial live load N01 included in total displayed or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS NOT considered In the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered In the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) , Soil Spring Reaction Modulus 250.0 pci pRo�sSraNy Horizontal DeftTop of Wall (approximate only) 0.160 in q*o ar�Rl]t?Cg, 2 7ht atxavRCalcuValioii is nn1 valid I lhr hesl„§oll b Qara1_n nsexsu�i . r�xceeds IM_I nl the toe.CIO t1e-cays 9. Ride watl_wqutd lh�n trsnd to fatale into illy relainorf soil- 4 D # . � N0.83660 L * EXP. 03/31/2021 r�r CIV!L ¢ v , � Op tP4�49 Project Name/Number : city of Is qu ORCO Block & Hardscape Title Clty of La Quints Page: 1 11100 Beach Blvd Dsgnr: GV Date: 8 OCT 2019 Stanton, CA 90680 Description.... Tel. (714) 527-2239 (02c) 6' wall w/3'-4" retaining This Wall in File: c:luserslgverdugolonedrive - orco block cam pan&ocumentsVelainpro project lites Rrismpra ts) 7>i67.2v1a, 9ttlttl 71.T9.13.2fi user": KW-M59401 Cantilevered Retaining Wall Code: CBC 2016,AC1 318-14,ACI 530-13 Llcense Ta : ORCO BLOCK COMPANY, INC. Criteria Retained Height _ 3.33 ft Wall height above soil 6.00 ft Slope Behind Wall = 0.00 Height of Soil over Toe 6.00 in Water height over heel 0.0 ft Surcharge Loads Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning I Axial Load Applied to Stem Axial Dead Load 0.0lbs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Design Summary Wall Stability Ratios Overturning 2.02 OK Sliding = 1.55 OK Total Bearing Load 1,930 Ibs ...resultant ecc. 9.69 in Soil Pressure a Toe = 1,858 psf OK Soil Pressure ® Heel = 0 psf OK Allowable = 2,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,601 psf ACI Factored @ Heel = 0 psf Footing Shear ® Toe = 9.4 psi OK Footing Shear ® Heel = 2.0 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 518.0 Ibs less 100% Passive Force = - 225,0 Ibs less 100% Friction Force = - 579.1 Ibs Added Force Req'd = 0.0 Ibs OK ...for 1.5 Stability = 0.0 Ibs OK Soil Data Allow Soil Bearing = 2,000.0 psf Equivalent Fluid Pressure Method Active Heel Pressure = 45.0 psf/ft Passive Pressure = 150.0 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115,00 pcf FootingjjSoil Friction = 0.300 Soil height to ignore for passive pressure = 12.00 in I Lateral Load Applied to Stem Lateral Load = 0.0 #/it ...Height to Top = 0.00 it ...Height to Bottom = 0.00 ft Load Type = Wind (W) (Strength Level) Wind on Exposed Stem = 26.7 psf (Strength Level) Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing Building Code CBC 2016,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 I w Adjacent Footing Load jacent Dot ng Load = 0.0 Ibs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Line Load Base Above/Below Soil at Back of Wall ffi 0.0 ft Poisson's Ratio = 0.300 I Stem Construction t 2nd Bottom Stem OK Stem OK Design Height Above Ftc ft= 3.33 0.00 Wall Material Above "Ht" = Masonry Masonry Design Method = LRFD LRFD Thickness = 6.00 8.00 Rebar Size = # 4 # 4 Rebar Spacing = 32.00 16.00 Rebar Placed at = Center Edge Design Data -... _ _._. __....._.__......__.......... ... fb/FB + fa/Fa 0.543 0.432 Total Force @ Section Service Level Ibs = Strength Level Ibs = 160.2 559.4 Moment.... Actual Service Level ft-# = Strength Level ft-#= 480.6 1,457.2 Moment..... Allowable ft-#= 884.2 3,368.0 Shear..... Actual Service Level psi = Strength Level psi= 9.1 6.1 Shear..... Allowable psi= 80.5 80.5 Anet (Masonry) in2 = 17.53 91.50 Rebar Depth 'd' In = 2.75 5.25 Masonry Date --� f'm psi = 2,000 2,000 Fy psi = 60,000 60,000 Solid Grouting No Yes Modular Ratio'n' = 16.11 16.11 Wall Weight psf= 42.0 78.0 o Equiv. Solid Thick. in = 3.90 7.60 a H4 ti Masonry Block Type = Medium Weight ¢�° yV-AauGp Masonry Design Method = LRFD Concrete Data �; m f'c psf Q l o A Fy psi = NO, 83660 A , j� EXP, 03/31/2021 v .;. l V 11. Oe+ g OF CALIF Project Name/Number : city of la qu ORCO Block & Hardscape Title City pf La Quinta Page: 2 11100 Beach Blvd Dsgnr: GV Date: 8 OCT 2019 Stanton, CA 90680 Description.... Tel. (714) 527-2239 (02c) 6' wall w/3'-4" retaining This Wall in File: c:luserslgverdugOonedrive - orco block company\documentsVelafnpro project Illes Licaneer KW-0Btlt9MI 1 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13 License To: ORCO BLOCK COMPANY, INC. Footing Dimensions & Strengths Too Width Heel Width - 3.00 Total Footing Width 3.00 Footing Thickness = 12.00 in Key Width = 12.00 In Key Depth 6.00 in Key Distance from Toe = 2.00 ft f'c = 2,500psi Fy = 60,000 psi Footing Concrete Density = 150.00pcf Min. As % = 0.0014 Cover ® Top 2.00 @ Btm;.-= 3.00 in Footing Design Results Toe Heel Factored Pressure = 2,601 0 psf Mu': Upward = 0 586 ft-# Mu': Downward = 0 1,990 ft-# Mu: Design = 0 1,403 ft-# Actual 1-Way Shear = 9.35 2.05 psi Allow 1-Way Shear = 40.00 40.00 psi Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Other Acceptable Sizes & Spacings Toe: Not req'd: Mu < phi"5"lambda'sgrt(f'c)"Sm Heel: Not req'd: Mu < phi"5"lambda'sgrt(f'c)"Sm Key: Not req'd: Mu < phi"5"lambda"sgrt(f'c)"Sm Min footing T&S reinf Area 0.60 in2 Min footing T&S reinf Area per foot 0.20 in2 ift If one layer of horizontal bars: If two layers of horizontal bars: #4® 11.90 in #4® 23.81 in #5 ® 18.45 in #5 @ 36.90 in #6@ 26.19 In #6@ 52.38 in Summary of Overturning & Resisting Forces & Moments ....,OVERTURNING..... RESISTING..... Force Distance Moment Force Distance Moment Item Ibs ft ft-# Ibs ft ft-# Heel Active Pressure = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load ® Stem Above Soil = Total 421.9 1.44 608.9 96.1 7.33 704.6 518 0 O.T.M. 1,313.4 Resisting/Overturning Ratio = 2.02 Vertical Loads used for Soil Pressure = 1,930.3 Ibs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered In the calculation of Overturning Resistance. Soil Over Heel = Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = " Axial Live Load on Stem = Soil Over Toe = Surcharge Over Toe = Stem Weight(s) _ Earth ® Stem Transitions = Footing Weighl = Key Weight = Vert. Component = 893.6 1.83 1,638.2 511.7 0.29 149.6 450.0 1.50 675.0 75.0 2.50 187.5 Total = 1,930.3 Ibs, R.M = 2.650.3 Axial live load NOT included in total displayed or used for overturning resistance, but is included for soil pressure calculation. Tilt ] Horizontal Deflection at Top!pj Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defi 0 Top of Wall (approximate only) 0.161 in 'f lie alMve ce1C1JW% r1$S 110t vallr 1f (hli tllael still beafing gtpcsure oxreeft that 91 the !e_e, Liacause the wail wouisi than tend to fatale into the ivia n I. o p e r rn lw. ate', NO. 83660 * EXP. WWI2021 OF cm,%f Project Name/Number : city of Is qu ORCO Block & Hardscape Title City of La Quints Page: 1 11100 Beach Blvd Dsgnr: GV Date: 8 OCT 2019 Stanton, CA 90680 Descrlptlon.... Tel. (714) 527-2239 (02d) 6' wall w/4'-0" retaining This Wall in File: c:luserslgverdugolonedrive - orco block companyldocumentslretainpro project files KeaunYra 0)1W-r-Xe1e, UU110 11,14.11.ZV Lkenvo! W-MOSMI License To. ORCO BLOCK COMPANY, INC. Cantilevered Retaining Wall Code: CBC 2016,AC1 318-14,AC1 530-13 Criteria Soil Data Retained Height = 4.00 ft Allow Soil Bearing = 2,000.0 psi Wall height above soil im 6.00 ft Equivalent Fluid Pressure Method I Active Heel Pressure = 45.0 psf/ft Slope Behind Wall = 0.00 , Height of Soil over Toe 6.00 in = Water height over heel 0.0 ft Passive Pressure = 150.0 psf/ft �. Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf Footingl]Soil Friction = 0.300 Soil height to ignore for passive pressure = 12.00 in _ hara Loads 9 --Surcharge � Lateral Load Applied to Stem Pp � W Adjacent Footing Load � Surcharge Over Heel = 0.0 psf Lateral Load = 0.0 #/ft A Parent Footing Load 0.0 lbs Used To Resist Sliding & Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft Surcharge Over Toe = 0.0 psf ...Height to Bottom = 0.00 it Eccentricity = 0.00 in Used for Sliding & Overturning Load Type = Wind (W) Wall to Ftg CL Dist = 0.00 ft Axial Load Applied to Stem I (Strength Level) e FootingType Line Load Axial Dead load - 0-0 Ibs Wind on Exposed Stem = 26.7 psf Above/Below Soil at Back of Wall 0.0 ft Axial Live Load = 0.0 Ibs (Strength Level) Poisson's Ratio = 0.300 Axial Load Eccentricity = 0.0 in Design Summary Wall Stability Ratios Overturning - 2.11 OK Sllding m 1.53 OK Total Bearing Load 2,352 Ibs ...resultant ecc. a 9.86 in Soil Pressure @ Toe = 1,953 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,000 psf Soil Pressure Less Than Allowable ACI Factored ® Toe = 2,734 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 10.7 psi OK Footing Shear @ Heel = 1.4 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 658.6 Ibs less 100% Passive Force = - 304.7 Ibs less 100% Friction Force = - 705.7 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 Stability = 0.0 Ibs OK Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing Stem Construction Design Height Above Ftc ft. Wall Material Above "Ht" - Design Method = Thickness = Rebar Size =. Rebar Spacing Rebar Placed at Design Data� fb/FB + fa/Fa - Total Force @ Section Service Level Ibs = Strength Level Ibs = Moment.... Actual Service Level ft-# = Strength Level ft-# = MomenL.,..Allowable ft-# = Shear.....Actual Service Level psi = Strength Level psi = Shear... -.Allowable psi = Anet (Masonry) in2 = Rebar Depth 'd' in = MasonryData - - I'm psi = psf = 2nd Stem OK 4.00 Masonry LRFD 6.00 # 4 32.00 Center Bottom Stem OK 0.00 Masonry LRFD 8.00 # 4 16.00 Edge 0.543 0.560 160.2 736.2 480.6 1.889.4 884.2 3,368.0 9.1 80.5 17.53 2.75 2,000 60,000 No 16.11 42.0 8.0 80.5 91.50 5.25 2,000 60,000 Yes 16.11 78.0 Load Factors -- ress rotiq Building Code CBC 2016,ACI Equiv. Solid Thick. In = 3.90 7.60 •\ Dead Load 1.200 Masonry Block Type = Medium Weight �wc. _4$RDU00 { r Live Load 1.600 Masonry Design Method = LRFD Earth, H 1.600 Concrete Data __ W Wind, W 1.000 f'c pshm ¢ Seismic, E 1.000 Fy psi d° No, 83660 EXP. W31/2021 ,, njRTF C/V ORCO Block & Hardscape 11100 Beach Blvd Stanton, CA 90680 Tel. (714) 527-2239 This Wall in File: Project Name/Number : city of la qu Title City of La Ouinta Page : 2 Dsgnr: GV Date: 8 OCT 2019 Description.... (02d) 6' wall w/4'-0" retaining - orco block company%documentsVetainpro project flies RawrWrcto)I907.2078, 6Cnitl11.18.11-W9 Ucerm : KtN-W591o1 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13 License To. ORCO BLOCK COMPANY, INC. Footing Dimensions & Strengths Toe Width = 0.000 Heel Width = 3.25 Total Footing Width = 3-25 Footing Thickness = 12.00 In Key Width 12.00 in Key Depth = 9.00 in Key Distance from Toe = 2.25 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % - 0.0014 Cover ® Top 2.00 0 Btm;= 3.00 in Footing Design Results I Toe Heel Factored Pressure = 2,734 0 psf Mu': Upward = 0 1,001 ft-# Mu': Downward = 0 2,758 ft-# Mu: Design = 0 1,757 ft-# Actual 1-Way Shear = 10.73 1.40 psi Allow 1-Way Shear = 40.00 40.00 psi Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Other Acceptable Sizes & Spacings Toe: Not req'd: Mu < phi'5'lambda'sgrt(f'c)`Sm Heel: Not req'd: Mu < phi'5'lambda'sgrt(f'c)'Sm Key: Not req'd: Mu < phl'5'lambda'sgrt(f'c)'Sm Min footing T&S reinf Area 0.66 in2 Min footing T&S reinf Area per foot 0.20 in2 At If one layer of horizontal bars: If two layers of horizontal bars: #4@ 11.90 in #4@ 23.81 in #5® 18.45 in #5@ 36.90 in #6® 26.19 in #6® 52.38 in Surnmery of Overturninal & Resistinci Forces & Moments OVERTURNING..... _-RESISTING..... Force Distance Moment Force Distance Moment Item Ibs If ft-# Ibs ft ft-# Heel Active Pressure = 562.5 1.67 937.5 Soil Over Heel 1,188.3 1.96 2,327.2 Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = Total 96.1 8.00 658.6 O.T.M. 769.0 1,706.5 Resisting/Overturning Ratio = 2.11 Vertical Loads used for Soil Pressure = 2,352.3 Ibs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soll pressure IS NOT considered in the calculation of Overturning Resistance. Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = ' Axial Live Load on Stem = Soil Over Toe = Surcharge Over Toe = Stem Weight(s) = 564.0 0.30 167.0 Earth ® Stem Transitions= Footing Weighi = 487.5 1.63 792.2 Key Weight = 112.5 2.75 309.4 Vert. Component = Total = 2,352.3 Ibs R.M.= 3,595.7 ' Axial live load NOT included in total displayed or used for overturning resistance, but is included for soil pressure calculation Tilt :Horizontal I?eflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.167 in The above qn(pulallon is nos valf ii 11}e he l s it b i re sure exams filet of the 14e. (] use 111e.wall w4uLd tllyir lend 10 rotate into the IeLAineUf 04 e�ypF�sSr�ti� ,� NO.83660 D - * EXP. 03/31/2021 * 7/ C I V `�' oQ,i, v:'.. t` OF CAL �F �/ ORCO STANDARD 6'--8" CMU SITE WALLS W/ SPREAD FOOTING FOR 110 MPH 3 SEC. GUST @ EXP C NOTE: PROVIDE 04 L7OWE' & #4 DROP -IN BAR AT FALH SIDE OF CONTROL JOINTS, ENDS OF WALLSAND @ WALL HEIGHT CHANGES OPTIONAL FLAT GAP ORCO 6816 OR 6616 CMU GROUTED ONLY @ VERT STEEL #4 - DROP -IN BAR @ 40" O/C @ CENTER OF CMU. #6 57DJOINT REINFORCEMENT @ 24" O/C (3 PLACES). USE #S STD. FOR SLUMP BLOCK NOTE: FOR SIDEYARD RETURN WALLS WHERE DRAINAGE SWALE OCCURES, A 112 BLOCK MAY LEFT OUT @ SWALE GRADE. PROVIDE #4 DOWEL AND #4 DROP -IN BAR ON EACH SIDE OF THE 112 BLOCK DRAIN. #4 DOWEL @ 40" O/C @ 34" CENTER OF CMU. L 10" EQUAL EQUAL LEVEL GRADE BOTH SIDES ;�I C I I #4 HOU CONT.rn 5' TO DAYLIGHT 2�-Zn xDTF: DIME Sl0.V5 ARENOT TO SCALE. DESIGN CRITERIA PER 2016 CZIC I. SOIL BEARING PRESSURE = ISM PSF+ 113 INCR. FOR WIND OR SEISMIC, EQUIVALENT FLUID PRESSURE = 45 PCF PER TABLE 1610A-1 2. ALLOWABLE LATERAL PASSIVE PRESSURE - 150 FIX 3. GROUT STRENGTH - 2000 PSI 28 DAYS. 4. RflNrVRC7NG STEEL : GRADE 60. S SEISMIC - I SEC. AQOSU37ATION - 70%. 6. 2000 PSI MASCWP Y C OMPRE.SSTON STRENGTH, NOM. 1. CTNNCIIETEBLOCK914LLCUWEURMTOA51MC90.ORCOS7D. PRECISION, SPLIT FAL7;. OR SLUMP BLOCK MAY BE USED. 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-412 PARTS SAND TO 3-IR PARTS GRAVEL WI1H A MAXIMUM OF 1-l12 GALLONS OF WATER PER SACK FOR7IAND CEMENT SHALL CONFORM TO A57M C 150 TYPE WV. Fc = 2500 PSI 3. REINFORCING S7EEL SHALL BE DEFORMED AND CONFORM TO ASTMA 615 GRADE 60, PROVIDE 48 BAR DIAMETER LAP. 4. REEVTR SHALL BE CENTERED IN THE CONCRETE BLOOCCELL IN WHICHITISLOGI7ED. S. CONCRETE BLOCKSHALL BELAYED INA STACK BOND P4T7FRN WITH VERTICAL CONRNUmOFTHE CELLS UNO. & ALL BLOCK CELIS CONTAINING VERTICAL RELAR SHALL BESOLID GROUTED. 7. USE OUP TYPE SMORTAR PROPOR77ONED UVNGASTM C27R 1 PART CTMEATT TO 112 PART LIME TO 4-112 PARTS DAMP, LOOSE SAND, 8. GROUT FOR CONCRETE LR.00K TO BE I PART CEMENT TO 3 PAR 75SAND (GROUT MAY CONTAIN 2 PART53)1- PFA GRAVEL IF WEATHER CONDI17ONSAREFAVORABLEAND BLOCK UP705SMUCTEC CALL SI2FI55UffIC7EWTTOALLOW000DGROUTRON9. WATER SHALL BE ADDED 70 PROD" GOOD GROUT ROW Wf7HOUr SEGREGARDN OF THE COIILSITU BM PER AS7M 476. 9. BLOCK STEM MAY BE WET --SET I-V/2"INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAYBE PLACED TO ETTHER EDGE OF THETREVaiTYPEFOOTlAn I fO077NG MUST BE POURED ON OR INTO UNDISTL4R r NATURAL SOIL OR ON COMPACIFD FILL WITH A MINIMUM COMPAC770NOF90%. 11. FIRST INSPEC7TON TO BEAF7ER FOOTTNG THE NLHESARE READY FOR CONCRETEAND ALL REQUIRED SIEEI IS TIEDIN PUACE. SECOND INSPE RON TO BEWHEN TIE REQUIRED VER77CAL ISM PLACEAND THE BLOOCWALL IS READY TO CROUr. 12 MAXIMUM CONTROL lOINTSPACING. 40' 01COR 20' 01CIF THE WALL IS TO BE STUCCO C04TED. ENGINEERING STAMPAPPROVALISCONDITIONAL; REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS CITY OF LA QUlINTA 54-080 AVENIDA OBREGON LA QUINTA, CALIFORNM r • -r,Q 4�R aL1GCi y < a .4 ra/o 7/r� ° A 03440 a y} EXP.013 V2021 C r V , 4 FI0% � OF CAL�F� Project Name/Number : city of Is qu ORCO Block & Hardscape Title City of La Quints Page: 1 11100 Beach Blvd Dsgnr: GV Date: 9 OCT 2019 Stanton, CA 90680 Description.... Tel. (714) 527-2239 (03) 6'-8" wall This Wall in File: C:WserslgverdugMOneDrive - ORCO Block CompanoDocuments\RetainPro Project Files 4 tl ra C 1 - ,: Bal Id 14. License: Kw-090594i11 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,AC1530-13 License To. ORCO. BLOCK COMPANY, INC. Criteria Retained Height 0.33 ft Wall height above soil zz 6.33 ft Slope Behind Wall a 0.00 Height of Soil over Toe :.is. 4.00 in Water height over heel = 0.0 ft Surcharge Loads Surcharge Over Heel = 0.p pst Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0lbs Axial Live Load 0.0lbs Axial Load Eccentricity = 0.0 in I Design Summary Wall Stability Ratios Overturning 1.51 OK Sliding 1.82 OK Total Bearing Load 662 Ibs ...resultant ecc. _ 8.60 In Soil Pressure ® Toe = 1,204 psf OK Soil Pressure e? Heel = 0 psf OK Allowable = 2,000 psf Sol[ Pressure Less Than Allowable ACI Factored @ Toe = 1,685 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 5.6 psi OK Footing Shear @ Heel = -1.6 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 141.4lbs less 100% Passive Force = - 58.3 Ibs less 100% Friction Force = - 198.6 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 Stability = 0.0 Ibs OK Soil Data Allow Soil Bearing = 2,000.0 psf Equivalent Fluid Pressure Method Active Heel Pressure = 45.0 psf/ft Passive Pressure 150.0 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe z 115.00 pcf FootingIlSoil Friction Q 0.300 Soil height to ignore for passive pressure 12.00 in Vertical component of active lateral soil pressure IS NOT considered In the calculation of soil bearing Lateral Load Applied to Stem Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom = 0.00 ft Load Type = Wind (W) (Strength Level) Wind on Exposed Stem = 26.7 psf (Strength Level) Adjacent Footing Load Adjacent Footing Load _ 0.0 Ibs Footing W Idth r 0.00 ft Eccentricity _ 0.00 in Wall to Ftg CL Dist n 0.00 ft Footing Type Line Load Base Above/Below Soil _ at Back of Wall 0.0 ft Poisson's Ratio 0.300 Stem Construction Bottom Design Height Above Ftg It= Stem OK 0.00 Wall Material Above "Ht" = Masonry Design Method = LRFD LRFD Thickness = 6.00 Rebar Size = # 4 Reber Spacing = 40.00 Rebar Placed at = Center Design Data fb/FB + fa/Fa 0.828 Total Force ® Section Service Level Ibs = Strength Level Ibs = 173.1 Moment.... Actual Service Level ft-#= Strength Level ft-# = 592.2 Moment..... Allowable 714.4 Shear..... Actual Service Level psi = Strength Level psi = 12.3 Shear..... Allowable psi = 80.5 Anet (Masonry) in2 = 14.03 Rebar Depth 'd' 1n = 2.75 Masonry Data - - f'm psi = 2,000 Fy psi= 60,000 Solid Grouting No Modular Ratio 'n' 16.11 Wall Weight psf = 41.0 Load Factors Building Code CBC 2016,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1,000 Seismic, E 1.000 Equiv, Solid Thick. in= 3.80 eRcrEsstoti�: Masonry Block Type = Medium Weight ��°. yERpUGp .. Masonry Design Method = LRFD Concrete Data - m rn ft psi = ti . ¢ m x v x it Fy psi = tan. 03640 ¢ / yF EXP- 03131tZO *' 'P C �v . qr f V t ¢� F OF CF Project Name/Number : city of la qu ORCO Block & Hardscape Title City pf La Ouinta Page : 2 11100 Beach Blvd Dsgnr. GV Date: 9 OCT 2019 Stanton, CA 90680 Description.... Tel. (714) 527-2239 (03) 6'-8" wall This Wall in File: CAUseraVvsrdugolOneDrive - ORCO Block CompanyLDocumentslRetainPro Project Files at n ra a 7 Lloemm;KW-06MasVg40i' Cantilevered Retaining Wall Code: CBC2016,ACI318-14,ACI 530-13 License To: ORCO BLOCK COMPANY. INC. Footing Dimensions & Strengths Toe Width = 0.83 ft Heel Width = 1.33 Total Footing Width = 2.17 Footing Thickness = 12.00 In Key Width - 12.00 in Key Depth = 0.00 in Key Distance from Toe = 1.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % - 0.0014 Cover ® Top 2.00 @ Btm;= 3.00 in Footing Design Results Toe Heel Factored Pressure = 1,685 0 psf Mid: Upward - 437 0 ft-# Mu': Downward - 102 102 ft-# Mu: Design = 335 102 ft-# Actual 1-Way Shear = 5.59 1.57 psi Allow 1-Way Shear _ 40.00 40.00 psi Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Other Acceptable Sizes & Spacings Toe: Not req'd: Mu < phi'5"lambda"sgrt(f'c)'Sm Heel: Not req'd: Mu < phi*5'lambda'sgrt(f'c)'Sm Key: No key defined Min footing T&S reinf Area 0.44 in2 Min footing T&S reinf Area per foot 0.20 in2 4t If one layer of horizontal bars: If two layers of horizontal bars: #4@ 11.90 in #4@ 23.81 in #50 18.45 in #5@ 36.90 in #6® 26.19 in #6® 52.38 In Summary of Overturning & Resist ria Forces & Moments .....OVERTURNING..... .....RESISTING..... Force Distance Moment Force Distance Moment Item Ibs ft ft-# Ibs ft ft-# Heel Active Pressure = 40.0 0.44 17.8 Soil Over Heel = 31.9 1.75 55.8 Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load ® Stem Above Soil = Total 101.5 4.50 456.5 141.4 O.T.M. 474.3 Res! sting/Overturning Ratio = 1.51 Vertical Loads used for Soil Pressure = 662.0 Ibs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = Axial Live Load on Stem = Soil Over Toe = Surcharge Over Toe = Stem Weight(s) _ Earth @ Stem Transitions= Footing Weighl = Key Weight - Vert. Component 31.9 0.42 13.3 273.3 1.08 296.0 324.9 1.08 351.9 1.50 Total = 662.0 Ibs R.M.= 717.0 Axial live load NOT included in total displayed or used for overturning resistance, but is included for soil pressure calculation. Tilt HoriNntal Deflec iart at Tors of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pcl Horizontal Defl @ Top of Wall (approximate only) 0.103 in Thp 90ve calculation is na1 valid i l_ lr,_e hagLsoiI pAkiring grgEVrer exceeds that of 11V too. b{ �a>e ll�e vial! wouid than tg tr dnrvtala into the relained soil. rf r eROFESS00�4 u m r11 m a � o NO.83660 n' # 1 EXP, 03/31/2021lp� 7F . P �4 ORCD STANDARD 6'-8" CMU SITE WALLS W/SPREAD FOOTING FOR 110 MPH 3 SEC. GUST @ EXP C N H NOTE: PROVIDE' a4 DOWEL & 04 DROP4N BAR AT EACH SIDE OFCOMROL JOINTS, ENDS OF WALLS AND @ WALL HFIGHTCHANGES FLAT CAP ORCO 6816 OR 6616 L74U GROUTED ONLY @ VERT STEEL 04 VERT DROP -IN BAR @ 40" O/C @ CENTER OF CMU. *6 STD JOINT REINFORCEMENT @ 24" O/C (3 PLACES). USE 05 STD. FOR SLUMP BLOCK. NOTE: FUR 5IDEYA AD RETURN WALLS WHERE DRAINAGE SWALE OOCURES, A 112 BLOCK MAY LEFT OUT @ SWALE GRADE. PROVIDE 04 DOWEL AND *4 DROP -IN BAR ON EACH SIDE OF THE 112 BLOC( DRAIN. DESIGN Cl?MRTA PER 2015 CAC 1. SOIL BE4ROVG PRESSURE = ISM PSF+ V3 INR. FOR WIND OR SEISMIC EQUIVALENT FLUID PRESSURE a 4S PCF PER TABLE 161CVA-1 Z ALLOWABLE LA7ERAL PASSIVE PRESSURE =150 PCF. 3. GROUT STRENG7H - 2000 PSI 28 VAYS 4. REINFORCINGSIFEL: GRADE60. 5. SEISMIC - I MC, ACUELBPA77ON = 7096. 6. 2000 PSI MASONR Y snov TH. NOTES• 1. CONCRETE BLOCK SHALL CONFORM TO A57N C90. ORCO STD. PRECTSICNV, SPLIT FACF, OR SLU4P BEOOC MAYBE USED, 2 CONCRETE FOR POOTAG S7fALL B'E1 PART CEMENT TO 2-112 PARTS SAND 70 3-1/2 PARTS GRAVEL WPN A MAXIMUM Of 1-1/2 GALLONS OF WA7ER PER SACK. FOR 7IANO CEMEMSMLL CONFORM TO ASTM C 150 7YPELVV. Fr = 2500 PST 3. REWAORCLNG 57EEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE49 BAR DIAMETER LAP. 4, RE84R SHALL BE CENTERED IN THE CONCRETE BLOCKC E L IN WHI0HITISLOGA7ID. S. CONCRETE BLOCKSIWl BELAYED IN STACK BOND PATTERN WITH VERTICAL 0ON77NUITY OF THE CELLS UNO. 6. ALL BLOCKCaLSOONTAINBW VERTICAL REB4R SHALL BE SOLID GROUTED. 7. USE OSPTVPES14ORTARPROPOR77ONEDUSINGASTM C270.1 PART CEMENT TO 1/2 PART LIME TO 4-1/2 A4RTS IIAMP, LOOSE SAW. & GROUT FOR CONCRETE BIOCKTO BE I PART CEMENT TO 3 PAR TSSOD (GROUT NAYCONTATN 2 PARTS" -PEA GRAVEL IF WEATHER CONDMONS ARE FA VORABLEAND BLOCK UNOBSTRUCTED cEu 5l2EISsufm ENT TO ALLOW GOOD GROUT ALOWJ. WATER SHALL BEADDED TO PRODUCE GOOD GROUT FLOW WrTHOUT SEGREGATION OF THE CYNIKITUEMS PER ASTM 476. 9. aocKSIDN MAY BE WET SET I-1/2"INTO THE FOOTING WHILE THE CDNCRE7E IS PL45T7C BLOCKSTHN MAYBEPLACED 70 EITHER EDGE OF THE TREN04 TYPE FVO lAK: 10. FOOTING MUST BE ADU)wD ON OR ILVTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF MW 11. PIRST INSPECTION TO BEAFTHR F0077NG 7R&VOIESARE READYFOR C OM RETEAND ALL REQUIRED STEEL 5 TIED IN PLACE. SECOND INVWT70N TO BE WHEN THE RE1 MED VERTIC:I L JS IN PLACEAND THE BLOCK WALL IS READY TO GROUT. 12. MAXIMUM QOYYTROL JOINT SA4(7NG 40'CYC OR 20' O/CIFTHE WALL iS TO 8FSTUCCO ODR7ED. 1-7 X4 DOWEL @ 40" O/C CENTER OFC L LEVEL GRADE BOTH SIDES u ENGINEERING STAMP APPROVAL IS CONDITIONAL; { — -- REQUIRING USE OF ORCO MANUFACTURED CMU ON ` ALL ORCO WALL SYSTEM DESIGNS. F 4V �fRDUGO C 4rya 04 ®40" OK 27 ''� !(ram �(L y • 6" a ! DVI 40 04 HORZ COAT NO. 83660 @12"0/C ExP.051311Z021 ,k TOP AND BOTTOM P ASSHOWN. s q L� 0L9" CONT. oq- lF o C A CITY OF LA QUANTA NOTE: DIMENSIONSARENOT TIJSLALE 54-080 AVENIDA QBREGON LA Q[)INTA, C4[IFDRNI.4 Project Name/Number : city of la qu ORCO Block & Hardscape Title City of La Quints Page: 1 11100 Beach Blvd Dsgnr: GV Date: 10 OCT 2019 Stanton, CA 90680 Description.... Tel. (714) 527-2239 (04) V-8" wall This Wall in File: C:1UserdlgverdugMOneDrive - ORCO Block Company0ocurnentMRetainPro Prejsci Files Criteria Retained Height = 0.33 it Wall height above soil = 6.33 it Slope Behind Wall = 0.00 Height of Soil over Toe = 4.00 in Water height over heel = 0.0 it Surcharge Loads Surcharge Over Hoes - 0.0 psi Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Design Summary Wall Stability Ratios Overturning = 1.64 OK Sliding 2.05 OK Total Bearing Load 772 lbs ...resultant ecc. 11.82 in Soil Pressure ® Toe = 1,319 psi OK Soil Pressure @ Heel = 0 psi OK Allowable = 2000,psi Soil Pressure Less Than Allowable ACI Factored ® Toe = 1,846 psi ACI Factored ® Heel = 0 psi Footing Shear 0 Toe = 5.6 psi OK Footing Shear ® Heel = 1.3 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 141.4 Ibs less 100% Passive Force = - 58.3 Ibs less 100% Friction Force = - 231.6 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 Stability = 0.0 Ibs OK Cantilevered Retaining Wall Soil Data Allow Sail Bearing = 2,000.0 psi Equivalent Fluid Pressure Method Active Heel Pressure = 45.0 psf/ft Passive Pressure = 150.0 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.300 Soil height to ignore for passive pressure = 12.00 in Vertical component of active lateral soil pressure IS NOT considered In the calculation of soil bearing Load Factors Building Code CBC 2016,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 Lateral Load Applied to Stem Lateral Load = 0.0 #/it ...Height to Top = 0.00 it ...Height to Bottom = 0.00 it Load Type = Wind (W) (Strength Level) Wind on Exposed Stem = 26.7 psi (Strength Level) Code: CBC 2016,ACI 318-14,ACI 530-13 I i_ .......... Adjacent Footing Load dfacent oting pad 0.0-lbs Footing Width 0-00 fl Eccentricity a 0.00 in Wall to Ftg CL Dist 0.00 it Footing Type Line Load Base Above/Below Soil _ at Back of Wall 0 0 it Poisson's Ratio = 0.300 Stem Construction Bottom Stem OK Design Height Above Ftg ft = 0.00 Wall Material Above "Ht" = Masonry Design Method = LRFD LRFD LRFD LRFD Thickness = 6.00 Rebar Size = # 4 Rebar Spacing = 40.00 Rebar Placed at = Center Design Data - fb/FB + fa/Fa _ 0.828 Total Force 0 Section Service Level Ibs = Strength Level Ibs = 173.1 Moment.... Actual Service Level it-# _ Strength Level it-#= 592.2 Moment..... Allowable = 714.4 Shear..... Actual Service Level psi = Strength Level psi = 12.3 Shear..... Allowable psi = 80.5 Anet (Masonry) in2 = 14.03 Rebar Depth 'd' in = 2.75 Masonry Data - f'm psi = 2,000 Fy psi = 60,000 Solid Grouting No Modular Ratlo'n' ZP 16.11 Wall Weight psi = 41.0 Equiv. Solid Thick. in = 3.80 / goof E rss aAV Masonry Block Type = Medium Weight r `. yERDuGo Masonry Design Method = LRFD Concrete Data f'c psi= w v M Fy psi = NO, BUM n i * EXP. OV31/2621 /* � �4r C. / V F OF CALVE Project Name/Number : city of Is qu ORCO Block & Hardscape Title City of Le Quints Page: 2 11100 Beach Blvd Dsgnr: GV Date: 10 OCT 2019 Stanton, CA 90680 Description.... Tel. (714) 527-2239 (04) 6'-8" wall This Wall in File: - ORCO Block Company\DocumentslRetainPro Project Files Kouint'ra jq 1tea 1-ZU Ia. W w I a Ilaa.11.1Y LloMsea Ti66941" Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13 Lice = o : ORCO BLOCK COMPANY, INC. Footing Dimensions & Strengths Toe Width = 0.00 ft Heel Width = 2.75 Total Footing Width - 2.75 Footing Thickness 12.00 in Key Width =: 12.00 in Key Depth 0.00 in Key Distance from Toe 1.00 it Pc = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0014 Cover ® Top 2.00 ® Btm;= 3.00 In Footing Design Results 1 Toe Heel Factored Pressure 846 0 psf Mu': Upward = 0 79 ft-# Mu': Downward = 0 635 ft# Mu: Design 0 556 ft-# Actual 1-Way Shear 5.59 1.28 psi Allow 1-Way Shear = 40.00 40.00 psi Toe Reinforcing = None Spedd Heel Reinforcing a None Speed Key Reinforcing = None Spec'd Other Acceptable Sizes & Spacings Toe: Not req'd: Mu < phi'5"lambda'sgrt(f'c)'Sm Heel: Not req'd: Mu < phi'5'lambdesgrt(f'c)'Sm Key: No key defined Min footing T&S reinf Area 0.55 in2 Min footing T&S reinf Area per foot 0.20 in2 /it If one layer of horizontal bars: If two layers of horizontal bars: #4® 11.90 in #40 23.81 In #5@ 18.45 in #50 36.90 in #6@ 26.19In #60 52.38 in Summary of Overtuming & Resisting Forces & Moments .....OVERTURNING..... .....RESISTING....: Force Distance Moment Force Distance Moment Item Ibs ft ft-# Ibs ft ft-# -- Heel Active Pressure = 40.0 0.44 17.8 Soil Over Heel = 86.2 1.63 140.0 Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load ® Stem Above Soil = _ Total 101.5 4.50 456.5 141.4 O.T.M. 474.3 _ Resisting/Overturning Ratio = 1.64 Vertical Loads used for Soil Pressure = 772.0 Ibs Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral loll pressure IS NOT considered in the calculation of Overturning Resistance. Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = • Axial Live Load on Stem = Soil Over Toe = Surcharge Over Toe = Stem Welght(s) _ Earth ® Stem Transitions= Footing Weighl = Key Weight - Vert. Component - 273.3 0.25 68.3 412.5 1.38 567.2 1.50 Total = 772.0 Ibs R.M.= 775.5 Axial live load NOT included in total displayed or used for overtuming resistance, but is included for soil pressure calculatlon. Tilt --- - - - 1 }loriixonial Deflection at Toga of_Wall _due to settlement of suit (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Deft @ Top of Wall (approximate only) 0.089 in The abava calculation Is not Jalld it the heal soil faNrfnc pressure on-oads tlAl of the tog, because the wall would then tend to rotate into the retained soil. QpOFTss�tl� d f_�[]UC,O; to r� ,v Ulm elm tiC L �v rF�► Va4� OF rf r--f 1 1 QaW CALIFORNIA PERMIT # , W — 01q� PLAN LOCATION: Project Address: 5 74 O V4UOProject Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN G ► Applicant Name: QtJat>`- Address: City, ST, Zip: Telephone: Email: Valuation of Project $ Contractor Name: r Qlk� New SFD Construction: Address: Conditioned Space SF City, St, Zip Garage SF Telephone: 7GG _ 4/ Patio/Porch SF Email: ` Fire Sprinklers SF State Lic: b 6 City Bus Lic: Arch/Eng Name: Construction Type: Occupancy: Address: Grading: City, St, Zip Telephone: Bedrooms: Stories: # Units: Email: State Lic: City Bus Lic: Property Owner's Name:AJ New Commercial / Tenant Improvements: Address: Total Building SF City, ST, Zip Construction Type: Occupancy: Telephone: Email: 78495 CALLE TAMPICO LA QUINTA, CA 92253 (760)777-7125 WWW.LAQUINTACA.GOV OFFICE USE ONLY # Submittal Req'd Rec'd Plan Sets Structural Calcs Truss Calcs Title 24 Calcs Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License Ii 100 LF 2!- 4-'RETalv1u& 61 4I4 tOM90 ' P/L 100' 6 r T SETSACI� < " 7{i;'•_ .-'•,;;-;'=: ��yy �, u3 � � � r ------ -- }ilph Point -- SETS K � 9,�,r n - - .� St 2!L 71 —1 — Anr.FT.i:t aF�ntin�o. u lope 2`r' Concrete Flat Work J _ O I O f op¢a` Concreta a Flat Work IJ �\ � b Concrete Flat Work—� r 6 HUAA,,oMso WW, LEI LLL l 1 _ I Concrete - Flat `'\'ork r L_-i "ter Concrete S j n.�nn.t 'ti E Flat Work -- i Cirnrirtc - 1 I Flat Work .t�'L7.F,t:li� 1 111 FSID _ F- ' 1 I -j Concrete Flat L5 uric W ` _ o 14,IG4 ri•L � dN14HsJ�L ! � �' eon 1 0 N 40 LF 6 M60 - WALL — is Flat WorkV GARDEN V/r\LL t9 ILL 04 W 5' --------------------�---- it - .-------------•----------------- 00' �I _--• r A { !r _ a -4 CITY of LA QUINT 2 - C MU - i BUILDING & SAFETY DE p Z APPROVED • FOR CONSTRUCTION y _ c Z z C DATE BY = < a M 015y 0n I Z tf2m CONSULTANTS. . klydpr & D,—mgs 1y Spo,ne Cwurn,c°nn lnr - -oir Tnndara Ln Pnrw D—Cr F.--2I 923&) ri, t5a/636 t0.rn,Lti1C'rL 10i'L ttA 0—a gr Fi Sipo,rrc Concnrc,i,ur ly -_ 72-651 n n dom La P I., D.- 760-567-7347 Ca. 92-160 I.k '5*1636 F;r-1;E31YICd[. 11 LA INA f 7 (�,•�,.p.i d Dranings hr Sy—, L--liooly SUILDING DIVISION ll y1 rh-r G nr /.n All., D--c 92260 ROAMED FOR CODE :.r1. Li, r581636 COMPLIANCE C11x: DA BY (WYER FL C0NTR4CTOR.. , , ... , , t7i„ & Dra up k. SO— C—t—H- 1- r rrarod noL- Pu1.n Desen Cn 91160 I !r a _81636 Patdd Snri114 54080411 . Obregan, La Quinta. C4 91253 34I-'?9-2311.i .23 ACRES WL lA' PARS 2 �Vea' PM 2271029 A f 3ry9I .AP,Nk 774-204-028-3 CalctlIation of the Net Lot Area Lot size - f 0000 sgti Total sgft of all proposed structure - 3336.00 sqft Net MARK Net lot area - 34% SCALE: DATE DESCRIPTION 1/8" = 1'-0" WALL LE❑L'Nn &-0• PRECISION BLOCK WAI L - WALLS '_'-a" PRF.fIS10N BLOCK WALL PROJECTNO: 022119 MODEL Ftl E' Casa La 9u-n!a 22 DRAWN BY: Bab SlpeSdc CHK'D BY: kC6n[oIX R i Na- COPYRIGHT COPYRIGHT Sipovac Construction Ina Ave. Obregon ' I SEWER LATERAL -T. C}st7fj•E�I:V, � PLAN NORTH 1. Dmeway approach requires a separate permit and inspection from City of La Quinta Public works Department. 2. Finishing floor shall be 12 inches above datum point at top of curb at centerline of lot. 3. Block Walls, Pools. Spas, Bbqs and Fire Pits requires a seperate permit from City of La� r� Quinta Building Depctrtmelit Monday, September 30. 2019 A-101 SHEET 4 OF 25 0 3 I` J I a 0 0 �. "K °0