Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BPLB2019-0132
78-495 CALLE TAMPICO U 4v LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Permit Type/Subtype: PLUMBING/ Application Number: BPLB2019-0132 Property Address: 79040 BIG HORN TRAIL APN: 776030022 Application Description: VANCE / GAS LINE INSTALLATION Property Zoning: Application Valuation: $1,800.00 Applicant: PD AZURE POOLS & SPAS INC P O BOX 10641 SEP 2 6 2019 PALM DESERT, CA 92255 - CITY OF LA QUINTA DESIGN & DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C53 License No.: •81U�9 Date. 9.26.19 Contractor: --3=— �= - OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec, 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant For the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis For the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale,). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.)- (_) I am exempt under Sec. , B.&P.C, for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/26/2019 Owner: VANCE, DOUGLASS ALLAN AND GUINALIN KAY 79045 COYOTE CREEK LA QUINTA, CA 0 Contractor: AZURE POOLS & SPAS INC P 0 BOX 10641 PALM DESERT, CA 92255 (760)322-7665 LIc. No.: 802919 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. RF I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued- My workers' compensation insurance carrier and policy number are: Carrier: FALI43AKFFIREAND CASUACTVCOMPAIVY Policy Number:FLA00857701 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall Forthwith comply with those provisions. Date: 9.26.19 Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE 15 UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set fort this application, 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above - .mentioned property for inspection purposes. Date: 9.26.1 9 Signature (Applicant or Agent): FINANCIAL • • DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT CITY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $101.97 Total Paid for PERMIT ISSUANCE: $101.97 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 5+ OUTLETS 101-0000-42401 0 $40.25 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 5+ OUTLETS PC 101-0000-42600 0 $26.83 Total Paid for PLUMBING 2019: $67.08 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 TOTALS:• t(V�PERMIT QW� K CALIFORNIA 3 2 0(� 'Z #—at-,o�3 PLAN LOCATION: Project Address: � �) Project Description: APN #: C 7- -7� w / 2 Z,�` Applicant Name: ,I Address: C Ecyi f 7 Jq- S Cc City, ST, Zip: - 14" Telephone: ;Ly pi 1 t, 1 • ©)k4 d . `L. 'I e Email: Project Valuation $ ' SDI Contractor Name: Lao � New Construction: Address: �, d,k Conditioned Space SF City, St, Zip /j/77 �22 Garage SF Telephone: I ot), Patio/Porch SF Email: ray Fire Sprinklers SF State Lic: �Z�j��l City Bus Lic: Architect/Engineer Name: Construction Occupancy: Address: Grading: City, St, Zip Telephone: Bedrooms: Stories: # Units: Email: State Lic: City Bus Lic: Property Owner's Name: naclw U New Commercial / Tenant Improvements: Address: - Total Building SF City, ST, Zip OI2IGY�> Construction Type: Occupancy: Telephone: Email: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 �uildina Aor) undatpid 1 _1 Q OFFICE USE ONLY # Submittal Required Received Plan Sets Structural Calcs Truss Calcs Title 24 Calcs CVWD Fire Flow Letter Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License 8: 59 inbox s1 LTE M1111 I. View n-QrQ-M" SoCa1Gas .(e,,,,,,,.,t,,,.,., Your Signed Contract Documents Were Processed Thank you for submitting ,Your signed contract documents wh!rh have ioeen reviewed and processed. Your contract will expire in accordance with its terms if work does not begin by 10/2112019, If no balance is due your Planning Rerresentative will :reform you of the estimated installation date 11 you have a balance due, work cannut'oe scheduled until SoCalGas'' has received and recorded full Payment Recording can take up io 10 business days due to bank Processing times Project Number 228336 5-Digit Access Code: 51781 Project Location 79040 BIG HORN TRL- LA QUINTA u If you have any questions please contact the New Business Process Team NBPROCESS- INLAND@SEMPRAUTILITIES.COM Thank you View the Status Your Project of Connect with Us' © © .a' u Explore SoCalGas® �ara;yus cam Ways to F'av Pay Bill :J��line � Hprt�e R�bales bus Hess Re vales 'iiy ,.fir ki�in :hCs.•'in�c Vo�'.vil�'[:a iC clS��iUJS C3n,ar.,:!r=i;��for ry.y.ii,r ;�lhn •xnnsil.� ;�, ., 'rir7 pa�;y INrINITY CATCH BASIN "I, EXISTING 5 BI OCK WALL PROJECT NOTES -All construction must comply with the 2016 California Building, Electrical, Mechanical, Plumbing, and Energy Codes -Special inspection required for shotcrefe placement per CBC Section 1705 and Table 1705.3 -Construction must comply with the California Swimming Pool Safety Act and SB 442 including•(2) drowning prevention safety features »Eln. u A, II J�� ••� .. Ym 5 POOL L- 1.51 t N�.IB ICY: eowvuFen r ner-A]rwr. EXISTING BBO LIC # C-s3, 802919 I P.O BOX 10641 PALM DESERT, CA 92255 I :i •-�1•'�_ OUiGOOR FPTIO I� OLD POOL LOCATION REMOVCL BY OTNERS !SOILS COMPACTION .^EPORT An ACIIED Insoeclfon qW Per Section 1705-3 and Table 1705.3 of the 2016 CBC Pneumatically Placed Shotcrete requires Special Inspection for Construction, Test Reports will be required from an approved agency detailing the following: MA,&$Imn4l M, _Strength tests for sholcreie shall be made by an approved agency on specimens that are representative of the wars: and which have been water soaked for at least 24 hours prior to testing, 1_928.IQ.l Sam jft Specimens shall be taken from the in -place work or from test panels, and shall be taken at least once each shift, but not less than one for each 50 cubic yards of shotcrete. 18Q8.1Q.2 Rp iLe_rjjL When the maximum -size aggregate is larger than 3/8 inch, the test panels shall have minimum dimensions of 18 inches by 18 inches- When the maximum -size aggregate is 3,18 in or smaller, the test panels shall have minimum dimensions of 12 inches by 12 inches. 199,4.1il.3 Arf&MUgre criteria. The average compressive strength of three cubes taken from the in -place work or a single test panel shall equal or exceed f', with no individual cube less than 0.88 f'�, Tocheck accuracy, locations represented by a —li,- nn r_ — r„he --h. h�ll ho raioclo :l EXISTING RESIDENCE EXISTING' BLOCK WALL PLO 101q - 0132_ TY OF LA QUINTA BUILDING DIVISION By: REVIEWED FOR BY: CODE - DOP'Ll�ii+ICE By: Y �} 13Y "mot' 3y: C r(y 'Y: ray: By: REi/ISI®NS POOL SPECS POOL SIZE: ZERO EDGE 22' X 57' SURFACE AREA: 1110 SO FT PERIMETER: 132' IDEPTH: 46" to -8, RAISED BOND BEAM: N/A SPA SPECS SPA SIZE: 20' X 9' SURFACE AREA: 194 SO FT PERIMETER: 62' JETS: 16 TBD SPA RAISED: '%ZEROEDGE EQUIPMENT PUMP: VS-3050 / 2.0 HP JETS FILTER: 420 SID HEATER: 2X 400K MT POOL LIGHT: 9 WHT GLOBRITES :SPA LIGHT: 2 WHT GLOBRITES FINSHES POOL COPING: TRAVERTINE :SPA COPING: TRAVERTINE DECKING:16 X 24 TRAVERTINE INTERIOR: PEBBLE WATERLINE: TILE I TBD SPILLWAY: TILE / TBD PROJECT: Scale: 1116" = 1 ft POOL AND SPA DATE: JUNE 1. 2019 SCALE 1/16" =1' SHEET A-1 Date: RESIDENCE: Date: N DOUG & GWEN VANCE Date: 79-045 COYOTE CREEK LA QUINTA, CA 92253 Date: Date: Date: Date: Date: Date: ALWAYS CALL DIG ALERT Z J� or 0 N A[! 9