BRES2019-023078-495 CALLE TAMPICO Da{Ai[�{/ VOICE (760) 777-7125
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011
DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 9/27/2019
Permit Type/Subtype: BUILDING RESIDENTIAL/ADDITION Owner:
Application Number: BRES2019-0230 VANCE, DOUGLASS ALLAN AND GUINALIN KAY
Property Address: 79045 COYOTE CREEK 79045 COYOTE CREEK
APN: 776030023 Vance Douglass Allen / Vance Guinalin Kay
Application Description: VANCE / 122SF ADDITION + PATIO EXTENSION LA QUINTA, CA 92253
Property Zoning:
Application Valuation: $25,000.00
Applicant: P
Contractor:
JAFF PAIGE OWNER BUILDER
POBOX 10067 SEP 2 7 2019
PALM DESERT, CA 92255
CITY OF LA QUINTA
DESIGN & DEVELOPMENT DEPARTMENT Llc. No.:
LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter I hereby affirm under penalty of perjury one of the following declarations:
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, I have and will maintain a certificate of consent to self -insure for workers'
and my License is in full force and effect. compensation, as provided for by Section 3700 of the Labor Code, for the performance
License Class: License No.: of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My rkers' compensation insurance carrier and policy number are:
Carrier: Palley Number: _
certify that In the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that. if I should1juKokire subject to the
workers' compensation provisions of Sectionn th bar C de, I shall forthwith
comply with those provisions, I r
Date.
Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to File a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permIt objects the applicant to a civil penalty of not more than five hundred dollars
as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within o)e year of completion, the owner -builder will have the burden of proving that
h ors did not build or improve for the purpose of sale,),
(Was owner of the property, am exclusively contractingwith licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thWa
and who contracts for the projects with a contractor(s) licensed pursuant to
ractors'StateLicense Law,).
m exempt under Sec. B.&P,C [or this reason
r�
Date: '2 Owner:
CONSTRUCTION LE t AGENCY
I hereby affirm under penalty of perjury that er is a construction lending agency for
the performance of the work far which this.p rmi is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's
Date: '_2-7_I Applicant
WARNING: FAILURE TO SECURE WORKERS' COMP 5 TION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAVIADDITION
ALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000)TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR ITION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work For 180 days will subject permit to cancellation.
I certify that I have read this application and state that the ab Formation is correct.
I agree to comply with all city and county ordinances and to law r lating to building
construction, and hereby authorize representatives of th city to ter u n the
above -mentioned property for inspection purposes.
Date:? --2 �F Signature (Applicant orAgen 1.� '
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT
CITY
AMOUNT
ADDITION, EA ADDITIONAL 500 SF
101-0000-42400
0
$137.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
ADDITION, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$38.42
DESCRIPTION
ACCOUNT
CITY
AMOUNT
ADDITION, FIRST 100 SF
101-0000-42400
0
$134.48
DESCRIPTION
ACCOUNT
CITY
AMOUNT
ADDITION, FIRST 100 SF PC
101-0000-42600
0
$188.92
Total Paid for ADDITION 2018: $499.50
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($125.00)
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HOURLY CHARGE - ESGIL STRUCTURAL ENGINEER
101-0000-42600
1.5
$125.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
HOURLY CHARGE - ESGIL STRUCTURAL ENGINEER
101-0000-42600
0
$55.00
Total Paid for BLDG CITY STAFF - PER HOUR: $55.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
BSAS SB1473 FEE
101-0000-20306
0
$1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES, FIRST 20
101-0000-42403
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES, FIRST 20 PC
101-0000-42600
0
$26.68
Total Paid for ELECTRICAL 2018: $53.36
DESCRIPTION
ACCOUNT
CITY AMOUNT
PLAN CHECK DEPOSIT - ADDITION/REMODEL 101-0000-42600 1 $125.00
Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $125.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RECORDS MANAGEMENT FEE - MAJOR
101-0000-42416
0
$21.00
Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00
DESCRIPTION
ACCOUNT CITY
AMOUNT
SMI - RESIDENTIAL
101-0000-20308 0
$3.25
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $3.25
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
ta Qa�fra
CALIFORNIA
PERMIT #
PLAN LOCATION:
Project Address: Q �p CQ 44,
Project Description: Ex. Pool, Remodel, Add't, Elect, Plumb, Mech
APN #: 7- o v- o �- I
Applicant Name: -�� [r
�� J-Zed /4 Ir�CA-01A-
Address:
l7 'b O'ey 10 010,7
City, ST, Zip: V v 1 b-C-S<t-�
M
Telephone: ( -1 ��- L ��7
Email: T\A) Ai' �� V 1 (� �� ��-
Valuation of Project $ (�U0, M
Contractor Name:
New SFD Construction:
Address:
Conditioned Space SF
City, St, Zip
Garage SF
Telephone:S
Patio/Porch SF
Email:
Fire Sprinklers SF
State Lic: City Bus Lic:
Arch/Eng Name:
bko,)o
Construction Type: Occupancy:
Address:
! I❑ S L,1 �4--' a n
Grading:
City, St, Zip
f M J! C S 10-
Telephone: b o 3 o 33
Bedrooms:
Stories:
# Units:
Email:
State Lic:
City Bus Lic:
Property Owner's Name: V 0\) 5 J «• 1 C-E
New Commercial / Tenant Improvements:
Address: `7 / I 5- d C &Lji�
Total Building SF
City, ST, Zip
3 Construction Type: Occupancy:
Telephone; &d
Email: 0 V9 0 (- fA$ `�`• Q�
V 78495 CALLE TAMPICD LA QUINTA, CA 92253 (760)777-7125
W W W. LAQU I NTACA. GGV
#
Submittal
Req'd
Rec'd
Plan Sets
Structural Calcs
Truss Calcs
Title 24 Calcs
Soils Report
Grading Plan (PM10)
Landscape Plan
Subcontractor List
Grant Deed
HOA Approval
School Fees
Burrtec Debris Plan
Planning approval
Public Works approval
Fire approval
City Business License
June 12, 2019
City of La Quinta
To Whom It May Concern:
I, Douglass Vance, give permission for our nephew, Jeff Paige, to handle any and all
documents necessary to submit plans, provide information and/or pull the permit for our
patio addition at 79045 Coyote Creek, La Quinta.
Thank you,
Douglass Vance
760-963-3427
RECEIVED
JUL 17 2019
CITY OF LA QIIINTA
DESIGN AND DMLOPMENT DEPARTMENT
Building Permit Number:
Project Description: room addition
Exempt: ❑
(Materials may contain hazardous wastes and
are not subject to recycling provisions)
Construction Debris Management Plan
Plan Submittal
Job Site Add
Owner's Name
Number, Street, or PO Box
City, State, Postal Code
Owner's Phone Number
Owner's E-Mail Address
1/1812019
79045 Coyote Creek
Douglas & Gwen Vance
79045 Coyote Creek
La Quinta, CA. 92253
c/o 760-902-0827
Project Manager's Namel Jeff Paige
Project Manager's Phone Number 760-902-0827
Project Manager's E-mail Addressl jwgaipel@y4prizon.net
Builder/Contractor Owner/Builder
Number, Street or PO Box 79045 Coyote Creek
City, State, Postal Codel La Quinta, CA. 92253
Project Square Footage[ Approx. 499 sq ft
CityApproval By Renado Gouldlock-DEC/Burrtec Waste
Date of City Approval a 1 f ( Ll I
Materials To Be Discarded:
Product Tons
1.80 Not recyclable
0.00 Recyclable
0.00 Recyclable
0.00 Recyclable
0.00 Recyclable
2.00 Recyclable
0.20 Recyclable
0.00 Recyclable
Trash
Asphalt
Brick/Block
Cardboard
Commingled
Concrete
Drywall
Donated / Reuse'
"Describe Items
RECEIVED
SEP 0 5 2019
CITY OF LA QUINTA
DESIGN AND DEVELOPMENT DEPARTMENT
Product
Masonry (broken)
Plaster
Scrap Metal
Tile (floor)
Tile (roof)
Wood
Landscape Debris
Tons
0.00 Recyclable)
0.50 Recyclable
0.00 Recyclable
0.05 Recyclable
0.06 Recyclable
0.70 Recyclable
0.00 Recyclable
Totals: Recycle Trash Projected Diversion:
3.5 1 1.8 66.10%
I understand it is the property owner's responsibility to submit copies of weight tickets or receipts to the District
Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the
Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste is
diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining
materials generated from the first day of the project through the completion of the project in accordance with this plan. This
DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or
demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still
issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the
DMP ar dhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through
bi-m thly r orts, elf -hauling, all ref a material from this project site must be taken to an approved recycler or transfer
O n r l Dev er 1 Prolec a er f uper ant Dat
Construction Debris Management Plan
Summary of Requirements
As of January 1, 2017, The Green Building Standards Code (CALGreen) requires that the construction
of most new structures in the State of California comply with sections 4.408 and 5.408 of the code in
accordance with Assembly Bill 936 requiring that no more than 35% of jobsite waste be disposed of as
trash at local land fill sites and transfer stations. Exceptions may be made for certain projects under
certain conditions.
The City of La Quinta is committed to the highest level of environmental respect, to conserving our
precious natural resources and setting an example to provide for a better world for generations to
come. Recycling helps keep reusable resources out of landfills and will also reduce disposal costs.
IMPORTANT: Burrtec Waste & Recycling Services is the City's franchise
hauler. If you choose to self -haul any recyclables or trash, you must
provide copies of all weight tickets and/or receipts from the transfer
station, landfill, or recycler as the job progresses. Clean-up companies
and other haulers are not permitted to haul waste or recyclables from the
City of La Quinta. Self -haul weight tickets should be submitted to:
Renado Gouldlock, District Environmental Coordinator -
rgouldlock@burrtecdesert.com, or faxed to (760) 340-0417, or mailed to:
41575 Eclectic Street, Palm Desert, CA. 92260.
p'reperty management
e Fa.. Seasons C.W—
■
Summer Alexander, CAI CA
summer(wavailhoa.corn
51350 Desert Club Drive
Suite 4
La Quinta. CA 92253
Tel: 760.771.9546
Fax:760.771.1655
service(uavailhoa.coin
PAINTED COVE AT LA QUINTA HOMEOWNERS ASSOCIATION
f Vfi APPLICATION FOR ARCHITECTURAL CHANGE �f
Name: (Please Print) /�� ' w ?� i Phoi,e:— �� / % L � n
Painted Cove Address:
Mailing Address (if Different): In
Proposed Starting Date:
Projected completion time:
Proposed Modification, Addition or Improvement: (Please check next to applicable boxes)
Pool or Spa - ($250.00 Deposit)
RECEIVED_ Water Feature - ($250.00 Deposit)
Room Addition/Enclosure - ($250.00 Deposit) SEP 0 5 2019
Skylight(s) - ($250.00 Deposit) CITY OF LA QUINTA
DESIGN AND DEVELOPMENT DEPARTMENT
Landscape - ($250.OD Deposit)
Detached Structure/Casita - ($250.00 Deposit)
_k1_ Patio Decking/Extension - ($250.00 Deposit) O_A-� lC%nGt'
Other - Specify:
($250.00 Deposit)
Description of Improvements desired (give full details of type and extent of Improvements):
Compliance Statement: As legal owner(s) of the above -referenced property, I (We) hereby state that this application and the plans submitted
are In compliance with the Association's "Architectural Guidelines and Application for Change." I (We) have reviewed the Guidelines, checked
off the appropriate items on the attached "Architectural Change Document List", and attach hereto -separate checks (payable to "PAINTED
COVE AT LA QUINTA Homeowners Association") for the $15. Recordation Fee (if needed) and corresponding Refundable Deposit.
By:_ Date:
Owner(s) Signature(s)
Samme c a exanden
Application/Plans Rec'd P.y:____
(Mgmt. Signature)
Application/Plans are: COMPLETE
PRINT NAME:
_NOT COMPLETE (Explain Below):
Application/Plans/Materials submitted to Architectural Committee on:
Application Reviewed on: 05/16/19 Approved orp5/23/19 Denied on
summer a&xata"
By:��
Committee Chair Association Manager
Date:
C5123119
Date: (14193119
Your architectural request was approved as submitted. Please ensure your vendors follow the rules and regulations.
Vendors are allowed Monday through Friday, not including holidays, between the hours of 7:00 am and 5:00 pm. Weekend work is
prohibited. Noisy equipment such as lawn mowers, hedge trimmers, leaf blowers, air compressors, circular saws, etc. are prohibited
before 7:00 am and after 5:00 pm.
PAINTED COVE AT LA QUINTA HOMEOWNERS ASSOCIATION
CONSTRUCTION REGULATIONS
*** Any damage done to common areas as a result of this construction must be repaired prior to
completion. The refundable deposit will be held until the Association receives a Notice of
Completion form and the Association inspect and approves the project. The Association may use
funds from the refundable deposit to correct any deficiencies. ***
1. No dirt, debris or other related construction material is to be dumped on any part of the PAINTED COVE property including
the undeveloped land, All excess material is to be disposed of off -site.
2. No material is to be delivered and placed in the street. Do not stockpile material on adjacent property. Contractors will be
required to place all pallets, cement and other materials in Owners driveway, yard or garage. Any material stockpiled in the
driveway is to be left In such a manner that it will not be an annoyance, visual distraction or a hazard to surrounding Owners.
Do not block any mailbox or street cleaning access.
3. All trash and debris is to be picked up daily and the street cleaned. Owner and contractor shall work with the Association
relating to the regular day the streets are cleaned. When a hazard has been created, such as an open trench, hole, exposed
wiring, etc., it must be barricaded in such a manner that injuries and accidents will be prevented.
4. If the property is currently being purchased, no work shall begin until escrow closes. Owner must verify property lines before
starting any work.
5. During the course of work, all vehicles shall be parked on the same side of the street so congestion will not be created. There
will be no parking in or blocking of the driveways of surrounding Owners.
6. All damages or non-compliance with these construction regulations must be repaired prior to the completion of the project,
If not corrected, the Association will complete the work and assess the Owner.
7. When applying surface material to concrete patios, walkways, etc., the Owner assumes risks for all damages, staining, and
breakage, which may be caused to Association or other homeowners' property.
8. Drainage systems must be confined to the Owner's property and designed to adequately carry the water away from the
structure and to the street.
9. Failure to comply with the above regulations may result in denial of the Contractor's entry Into PAINTED COVE.
10. No loud music. Workers are to respect adjacent properties. Not to be used for breaks and/or lunches.
11. Instructed on gate operation.
12. CONTRACTOR WORK HOURS:
Monday — Friday -7,00 a.m. 5:00 p.m.
Saturday, Sunday, Holidays Prohibited 11
Owne &/2l tV Address: ��%() S J patercj/%
Print Name and Slen / �•
Contractor: e �^ � CA Lic. #: �02 % I Phone:�0_ � —7(- � S
Print Name
PAINTED COVE AT LA QUINTA HOMEOWNERS ASSOCIATION
CONDITIONS OF APPROVAL AND DISCLAIMER
1 Unless specifically agreed otherwise In writing by the Board of Directors, approval of the submitted plans is the responsibility of the
Association and is also conditioned upon the Owner agreeing to assume the cost for any additional maintenance directly or indirectly
caused by the proposed modificatlon(s), addition(s), or improvement(s).
2. During the approval process, the Association may require that its architect, landscape consultant, attorney, contractor, etc.,
review the proposed plans. The Owner will be required to reimburse the Association for any of these expenses. Such reviews are
very limited in scope and may not be relied upon by the Owner to ensure correctness of plans from either a legal, architectural,
structural, engineering, landscaping, etc, standpoint.
3. The Owner further agrees and represents that as a condition of submittal, he/she has Independently reviewed and confirmed that
the proposed plans are correct from a legal, structural, architectural, engineering, and/or landscaping standpoint and will not in any
way, other than that which has been disclosed in the application, negatively impact the Association or cause damage or additional
maintenance to Association owned and/or maintained property.
4. The Owner further agrees and represents that he/she has complied with all applicable Federal, State, County and City laws and
ordinances and has obtained all necessary permits in connection with the proposed plans. Applicant further agrees not to commence
the proposed project plans until the Association approves the architectural change application.
PLEASE NOTE THAT APPROVAL OF THE PROPOSED PLANS BY THE ASSOCIATION DOES NOT
CHANGE OR ABROGATE THE APPLICANT'S OBLIGATION TO OBTAIN ALL NECESSARY PERMITS
AND/OR COMPLY WITH ALL APPLICABLE GOVERNMENTAL REGULATIONS.
Agept[:d by,
Dated:
wner"iena to re
Owner's Name (Print) ~o��-r �-`oulrrg�— ( 7
Address of Property to Improved
PAINTED COVE AT LA QUINTA ASSOCIATION
ARCHITECTURAL CHANGE
Contractor c0111pllance Statement & Document Submittal
OWNER: LJLL����G� PAINTED COVE ADDRESS:
PINT
CONTRACTOR: r PHONE #: 76,
CONTRACTOR MAILING ADD
CA LICENSE #:.•_ n r 1 EMERGENCY CONTACT
JOB SUPERINTENDENT:�.�_i
TYPE OF MODICATION/ADDITION/IMPROVEMENT(S):
DATE OF ORIGINAL PLANS SUBMITTED:
PHONE #: 7C,2—C-4- �
Compliance Statement: As Legal representative/agent of the above -referenced Owner at Painted Cove at La Quinta, I hereby
state that the documents checked below were duly submitted to the Association's management agent on
and that said documents are complete and in accordance with the Association's "Architectural Guidelines and Application for
Change." Once approved, I pledge to abide by the Association rules and regulations regarding construction, parking and
conduct while on property,
BY:
CONTRACTOR SIGNATURE
DATE:
Documents Submitted: (Please consult guidelines for number and types of plans needed)
FEES & FORMS
$ Refundable Deposit
$15. Recordation Fee (for Agreement & Covenant Only)
Adjacent/Facing Neighbor Comment Form
Conditions of Approval and Disclaimer Form
Construction Regulations Form
Agreement and Covenant Running with the Land Form
Send to: Painted Cove At La Quinta Homeowners Association
Architectural Review Committee
c/o Avail Property Management
51350 Desert Club Drive, Suite 4
La Quinta, CA 92253
PLAN DRAWINGS
Plot Plan
Elevations
Preliminary Floor Plan
Landscape/Irrigation/Light Plan
Hordscope Plan
Roof Changes & Connections
Phone: 760-771-9546/ Fax: 760-771-1655 Email: service@availhoa.com
I
'-O' 'El E 10 DO
LA O IWA O OTHER
PALAZZO
r—
:g i:oetrPni:.�5::cin
t
]-
iY
x�
GaNa:xt'xF.t
-
�tvre-./\4'i �L`adit[iNYNin
7-W
+Y o�iyw!e-x.`aplf lq�fi0sz �sa�
SSapc
sr: ge--na^ >aTllwrx1411'ze
cac=vs Pmen
^
CONSTRUCTION LEGEND
SYM
I GOMME
I
POOL N17H O' + OR -INFINITY EDGE
C4>•?R!Y ipIC
FINf� GRAD= '- Hr i0 _ pErFFY.�_�'�
OPOOL.
GGPINS W/ ZERO EDGE EFFECT
3
III- PiT
d
I EXISTING CONCRETE WALK
ca cR Aw F
5
PROPOSED DECK AND ENTRY WALK
FINAL MA M
ARTIFICIAL TURF 3AND5
15PA WITH 5EAGH ENTRY
SL0.x A.`r7 5-
r_
�/
POOL SPILLWAY 71OU6H
9
EX1571N& B30_ AREA
FIEF Exn:r
10
PROPOSED PICKLE BALL COURT
vc�wr bra c
.II
PROPOSED ENTRY WALK
w4w
EXI5TIN5 TREE
FIE! O VERIFY
/iO�
113I
EXISTING RE5IDENGE
Cd4o - CITY OF LA QUINTA SUB -CONY ACTORaLIST
JOB ADDRESS % f QHS �-��-V-- PERMIT NUMBER �. 5�-()11 IER . _ �—� aBUILDER
This farm shall be hosted on the iob with the Building Inspection Card at all times in a conspicuous_ place. Only persons appearing on this list or their employees are authorized to work
on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance
of building permit. For each applicable trade, all information requested below must be completed by applicant. "On File" is not an acceptable response.
Trade 1 Classification
Contractor ..
State Contractor's License
Workers.-Cb[ilpetssation insurance
City Bus ine.ss License
Company Name
Classification
(e.g. A, B, C-8)
License Number
(xxxxxx)
Exp. Date
(xx/xx/xx)
Carrier Name
(e.g. State Fund, CalComp) I
Policy Number
(Format Varies)
Exp. Date
(xx/xx/xx)
License Number
(xxxx)
Exp. Date
(xx/xx/xx)
EEARTHWORK (C-1::2}
M R C0V-%4y l7 A-00 h
IN�
\AI&S (o
v-4 W c,3H 1 161 u 1
b S—)-O
CONCRETE (C-8)
%Ck CCx\c4Q_
A-- L-v
C�`��"�a ►s7LQ
LJ-340
FRA M I.I, G:.(:C=5:1
/ \ �" �� 1 F`%
t7
6 3 D-- Z Q
We-5 Co
V" 3 `-� SL�
b ~S �C1
STRUCT STEEL (G51).
D L w0R,�S
C,- S�1+/1G1
b� `�
-1���
MASONRY (C-2,S)
_
PLUMBING (C-36)
�! v �\�
�.-3b
���bo�3
-31-a1
>(emppf-
LATH, PLASTER (C-35)
kuV\ 1Ff\L Ccx\_S4
o53S760
5-31-}I
&Y &'�
DRYWALL (c-9)
P\'V\ gem" �M vJq\
`' 61-0
C+-CA
5 *f1A4
\SAO W (0k3JJJJ
L 1,17-1
HVAC (C-20)
S.� e1�; o� f\
c,- a-o
�t ��q� b
2
c��L►k� ��
Svw Co3 DLIS-I
N-aQ�.-z�
ELECTRICAL (C-1D:}
Soot V Kk Oc
�-' l�
V :- - \ _71
��3 41
r
f\Aii eo&o
S7&6CcA I�loi
0`v a0
ROOFING (C-3g}i\,ry5
�l7F`
�
�-1��"
a'a�-%D
�' Cow
SHEET METAL. (C 43)
FLOORING (C-15)
GLAZING (.C-17)
V E E-)
INSULATION (0•2)
19
----
Sr WAGE, LISP. (C-42) -
C
(OF LA QUINTA
PAINTING (C-33)
0'L71\ \1�iN A{�d
` �
d'C1� 1
l
�-3��yo
1 �� V'f
p r
��� 0� D �J
L'I� ' } 0
CERAMIC TILE (C-54)
CABINETS (c-s)
�� CvS�OM
Q U
Stiav,t( 6�
C)Ob0101°!
FENCING (C-13)
LANDSCAPING (:C•27)
POOL.,(C-531. -. -..
V G f)00\-S
C - S3
d cl
(
�-30-10\
IAA 5 Kc
_LA LroBS?7o (
3-) 0
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District1�0
47950 Dune Palms Road ' i}A;♦u"s; �.
Date: 9/27/2019 La Quinta, CA 92253 ac yf�Y
No.: 19-01488-1 (760)771-8515
Owner: Douglass Allan and Guinalin Kay Vance Email:
Address: 79-045 Coyote Creek Jurisdiction: La Quinta
City: La Quinta
Type: Residential Addition < 500 Sq ft
Lot # Street No.
79-045
Comments:
Street Name
Coyote Creek
Tract #:
Sq. Feet APN
122 776-030-023
RECE' 1177)
SEP 2 7 2019
CITY OF LA QUINTA
DESIGN AND DEVELOPMENT DEPARTMENT
Permit No.
BRES2019-0230
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions
under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement
mobile homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
Exempt
This certifies that school facility fess imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 122 S.F. or $0.00 have been paid for the property listed above and that building permits
and/or Certificates of Occupancy for this square footage in the proposed project may now be issued.
Fees Paid By: E in ante
Bank Name/Recipient of Certificate
By Scott L. Bailey
Superintendent
Fee Collected/ Exempted by:
Arianne Catano
Check No..
Telephone: 760-413-0584
Funding: Exempt
Certificate Fees Due: $0.00
Original Payment(s) Rec'd: $0.00
New Payment Rec''d: $0.00
Over,/Under: $0.00
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you ir.ay protest the fees or
other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL.
T4hf 4
P.O. Box 1504
LA QUINTA, CALIFORNIA 92247-1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
44"
BUILDING &z SAFETY DEPARTMENT
PROPERTY OWNER'S PACKAGE
(760)777-7012
FAX (760) 777-7011
Disclosures & Forms for Owner -Builders Applying for Construction Permits
IMPORTANT! NOTICE TO PROPERTY OWNER
Dear Property Owner:
An application for a building permit has been submitted in your name listing yourself as the builder of the property
improvements specified at Q T � Jz L
We are providing you with an wner-Buil er k4mow7tedgment and Information Verification Form to make you aware of your
responsibilities and possible risk you may incur by having this permit issued in your name as the
Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision,
signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice
unless you, the property owner, obtain the prior approval of the permitting authority.
OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION
DIRECTIONS.- Read and initial each statement below to signify you understand or verify this information.
�u�ilding
1. I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder" permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as
an Owner-Hui€der, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person
and his or her employees while working an my property. My homeowner's insurance may not provide coverage for those
injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers
on my property.
�2. I understand building permits are not required to be signed by property owners unless they are responsible for the
construction and are not hiring a licensed Contractor to assume this responsibility.
��3. I understand as,an "Owner -Builder" I am the responsible party of record on the permit. I understand that I may protect
oval, f from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my
own.
Q16. I understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on
permits and contracts.
�5, I understand if I employ or otherwise engage any persons, other than California licensed Contractors and the total value
of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer"
under state and federal law.
6. I understand if 1 am considered an "employer" under state and federal law, I must register with the state and federal
goventmem, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment
compensation for cacti "employee." I also understand my failure to abide by these laws may subject me to serious financial
risk.
�/7. 1 understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential
structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed
subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed
under contract with a licensed general building Contractor.
TABLE OF CONTENTS
CERT' \TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: Vance Addn
Calculation Description: Title 24 Analysis
VIQ11
Calculation Date/Time: 11:01, Mon, Jul 15, 2019
Input File Name: Vance Addn LQ-Coyote Creek.ribdl6x
CF 'JRF-01
Page 1 of 10
GENERAL INFORMATION
01
Project Name
Vance Addn
02
Calculation Description
Title 24 Analysis
03
Project Location
79-045 Coyote Creek
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.3.1 (1149)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.2
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
180
12
Project Scope
Addition and/or Alteration
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ftZ)
4579
15
Number of Zones
5
16
Slab Area (ftZ)
4579
17
Number of Stories
1
18
Addition Cond. Floor Area (ftZ)
122
19
Natural Gas Available
Yes
20
Addition Slab Area (ftZ)
122
21
Glazing Percentage (%)
17.5%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building DOES NOT require HERS Verification
03
This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft -yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
4.59
4.47
0.12
2.6%
Space Cooling
164.85
164.45
0.40
0.2%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water Heating
6.47
6.47
0.00
0.0%
Photovoltaic Offset
--
0.00
0.00
—
Compliance Energy Total
175.91
175.39
0.52
0.3%
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
Registration Number: Registration Datef-l-ime: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-15 11 i02:23
CERT' 1TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE 'HOD CF 'RF-01
Project Name: Vance Addn Calculation Date/Time: 11:01, Mon, Jul 15, 2019 Page 2 of 10
Calculation Description: Title 24 Analysis Input File Name: Vance Addn LQ-Coyote Creek.ribd16x
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
- --None—
Cooling System Verifications:
• -- None —
HVAC Distribution System Verifications:
• -- None --
Domestic Hot Water System Verifications:
• -- None —
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Vance Addn
4579
1
4
5
0
2
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Living Zone
Conditioned
HVAC-Livingl
2494
11.5
DHW Sys 1
n/a
Living Room Addition
Conditioned
HVAC-Livingl
122
11.5
DHW Sys 1
n/a
Sleeping Zone
Conditioned
HVAC-Sleeping2
1483
10.5
DHW Sys 1
n/a
Master Closet
Conditioned
HVAC-Sleeping2
172
10
DHW Sys 1
n/a
Casita Zone
Conditioned
HVAC-Casita3
308
10
DHW Sys 3
n/a
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-15 11:02:23
CERT.' ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: Vance Addn
Calculation Description: Title 24 Analysis
'HOD
Calculation Date/Time: 11:01, Mon, Jul 15, 2019
Input File Name: Vance Addn LQ-Coyote Creek.ribd16x
CF IRF-01
Page 3 of 10
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
10
11
Name
Zone
Construction i
Azimuth
Orientation
Gross Area
(ft2)
Window & Door
Area (ft2)
Tilt
(deg)
Wall
Exception
Status
Verified
Existing
Condition
N Wall
Living Zone
Existing Wall
0
Back
562
48
90
n/a
Existing
No
E Wall
Living Zone
Existing Wall
90
Right
570
364
90
n/a
Existing
No
S Wall
Living Zone
Existing Wall
180
Front
658
110
90
n/a
Existing
No
W Wall
Living Zone
Existing Wall
270
Left
180
58.4
90
n/a
Existing
No
Roof 3
Living Zone
Existing Roof
2494
n/a
Existing
No
New S Wall
Living Room Addition
New R-21 Wall
180
Front
372
0
90
none
New
n/a
Interior Surface
Living Room Addition»Living
Zone
New Interior Wall
372
0
n/a
New
n/a
Interior Surface 2
Living Room Addition»Living
Zone
New Interior Wall
54
0
n/a
New
n/a
Interior Surface 3
Living Room Addition»Living
Zone
New Interior Wall
54
0
n/a
New
n/a
Roof 4
Living Room Addition
New R-38 Roof Attic
122
n/a
New
n/a
N Wall 2
Sleeping Zone
Existing Wall
0
Back
360
22
90
n/a
Existing
No
E Wall 2
Sleeping Zone
Existing Wall
90
Right
285
48
90
n/a
Existing
No
S Wall 2
Sleeping Zone
Existing Wall
180
Front
346
64
90
n/a
Existing
No
W Wall 2
Sleeping Zone
Existing Wall
270
Left
688
16
90
n/a
Existing
No
Roof 5
Sleeping Zone
Existing Roof
1483
n/a
Existing
No
N Wall 3
Master Closet
R-21 Wall
0
Back
80
0
90
n/a
Existing
No
W Wall 3
Master Closet
R-21 Wall
270
Left
215
0
90
n/a
Existing
No
Interior Surface 4
Master Closet—Casita Zone
R-13 Wall
80
0
n/a
Existing
No
Roof 6
Master Closet
R-38 Roof Attic
77.3
n/a
Existing
No
E Wall 3
Casita Zone
R-19 Wall (W. 1 9.2x6.16)
90
Right
195
72
90
n/a
Existing
No
S Wall 3
Casita Zone
R-19 Wall (W. 1 9.2x6.16)
180
Front
133
0
90
n/a
Existing
No
W Wall 4
Casita Zone
R-19 Wall (W. 1 9.2x6.16)
270
Left
195
0
90
n/a
Existing
No
Interior Surface 5
Casita Zone»Master Closet
R-0 Interior Wall
80
0
n/a
Existing
No
Roof 7
Casita Zone
R-38 Roof Attic
1
1 307.65
1
1n/a
Existing
No
Registration Number: Registration DateMme: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-15 11:02:23
CERTI TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: Vance Addn
Calculation Description: Title 24 Analysis
HOD
Calculation Date/Time: 11:01, Mon, Jul 15, 2019
Input File Name: Vance Addn LQ-Coyote Creek.ribd16x
CF "RF-01
Page 4 of 10
OPAQUE SURFACES — Cathedral Ceilings
01
02
03
04
05
06
07
08
09
10
11
12
Name
Zone
Type
Orientation
Area
W)
Skylight
Area (ft2)
Roof Rise
(x in 12)
Roof
Reflectance
Roof
Emittance
Cool
Roof
Status
Verified
Existing
Condifion
Roof
Master Closet
R-38 Roof Attic1
Left
0.8
0.7
0
0.1
0.85
No
Existing
No
Roof 2
Casita Zone
R-38 Roof Attic1
Left
0.45
0.35
3
0.1
0.85
No
Existing
No
ATTIC
01
02
03
04
05
06
07
08
09
10
Name
Construction
Type
Roof Rise
Roof
Reflectance
Roof
Emittance
Radiant
Barrier
Cool
Roof
Status
Verified Existing
Condition
Attic Living Zone
Attic RoofLiving Zone
Ventilated
3
0.1
0.85
No
No
Existing
No
Attic Living Room Addition
Attic RoofLiving Room Addition
Ventilated
0
0.1
0.85
Yes
No
New
No
Attic Sleeping Zone
Attic RoofSleeping Zone
Ventilated
3
0.1
0.85
No
No
Existing
No
Attic Master Closet
Attic RoofMaster Closet
Ventilated
0
0.1
0.85
Yes
No
Existing
No
Attic Casita Zone
Attic RoofCasita Zone
Ventilated
3
0.1
0.85
Yes
No
Existing
No
Registration Number: Registration Dateffime: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-15 11:02:23
CERTf LTE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: Vance Addn
Calculation Description: Title 24 Analysis
4OD
Calculation Date/Time: 11:01, Mon, Jul 15, 2019
Input File Name: Vance Addn LQ-Coyote Creek.ribdl6x
CF "RF-01
Page 5 of 10
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multiplier
Area (ft)
U-factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
Exist. Win.
N Wall (Back-0)
-
-
1
48.0
0.71
0.60
Insect Screen (default)
Existing
No
Exist. Win. 2
E Wall (Right-90)
-
1
64.0
0.71
0.60
Insect Screen (default)
Existing
No
Exist. Win. 3
E Wall (Right-90)
-
--
1
4.5
0.71
0.60
Insect Screen (default)
Existing
No
Relocated Window
E Wall (Right-90)
22.5
10.0
1
225.0
0.71
0.60
Insect Screen (default)
Existing
No
Relocated Window 2
E Wall (Right-90)
7.5
8.0
1
60.0
0.71
0.60
Insect Screen (default)
Existing
No
Exist. Win. 4
E Wall (Right-90)
--
-
1
4.5
0.71
0.60
Insect Screen (default)
Existing
No
Exist. Win. 5
E Wall (Right-90)
--
--
1
6.0
0.71
0.60
Insect Screen (default)
Existing
No
Exist. Win. 6
S Wall (Front-180)
-
-
1
30.0
0.71
0.60
Insect Screen (default)
Existing
No
Exist. Win. 7
S Wall (Front-180)
-
1
80.0
0.71
0.60
Insect Screen (default)
Existing
No
Exist. Win. 8
W Wall (Left-270)
-
-
1
58.4
0.71
0.60
Insect Screen (default)
Existing
No
Exist. Win. 9
N Wall 2 (Back-0)
--
-
1
16.0
0.71
0.60
Insect Screen (default)
Existing
No
Exist. Win. 10
N Wall 2 (Back-0)
-
--
1
6.0
0.71
0.60
Insect Screen (default)
Existing
No
Exist. Win. 11
E Wall 2 (Right-90)
-•-
-
1
48.0
0.71
0.60
Insect Screen (default)
Existing
No
Exist. Win. 12
S Wall 2 (Front-180)
1
64.0
0.71
0.60
Insect Screen (default)
Existing
No
Exist. Win. 13
W Wall 2 (Left-270)
-
--
1
16.0
0.71
0.60
Insect Screen (default)
Existing
No
Skylight
Roof (Left-270)
--•
-
1
.4
0.30
0.30
None
Existing
No
Skylight 2
Roof (Left-270)
1
.4
0.30
0.30
None
Existing
No
Exist Win.
E Wall 3 (Right-90)
-
-
1
48.0
0.71
1 0.60
Insect Screen (default)
Existing
No
Exist. Win. 14
E Wall 3 (Right-90)
-
1 1
24.0
0.71
0.60
Insect Screen (default)
Existing
No
Skylight 3
Roof 2 (Left-270)
--
--
1
.4
0.30
0.30
None
Existing
No
OVERHANGS AND FINS
01
02 03
04
05
06
07
08
09
10
11
12
13
1 14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
Relocated Window
16
0.1
16
16
0
0
0
0
0
0
0
0
0
Relocated Window 2
16
0.1
16
16
0
0
0
0
0
0
0
0
0
Registration Number: Registration Dateffime: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-15 11:02:23
CERT \TE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: Vance Addn
Calculation Description: Title 24 Analysis
'HOD
Calculation Date/Time: 11:01, Mon, Jul 15, 2019
Input File Name: Vance Addn LQ-Coyote Creek.ribd16x
CI 'RF-01
Page 6 of 10
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-factor
Assembly Layers
• Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck., Wood Siding/sheathing/decking
Attic RoofLiving Zone
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
Existing Roof
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 30
0.032
Over Ceiling Joists: R-20.9 insul.
• Inside Finish: Gypsum Board
R 19 in 5-1/2 in.
Cavity/Frame: R-19 in 5-112 in. (R-18) /2x6
Existing Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
cavity (R-18)
0.074
Exterior Finish: 3 Coat Stucco
• Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofLiving Room Addition
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
New R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Ceiling Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Sheathing / Insulation: R5 Sheathing
• Cavity/Frame: R-21 /2x6
New R-21 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.048
Exterior Finish: 3 Coat Stucco
• Inside Finish: Gypsum Board
• Cavity/Frame: no insul. /2x4
New Interior Wall
Interior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
none
0.277
Other Side Finish: Gypsum Board
• Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofSleeping Zone
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing., Light Roof (Asphalt Shingle)
• Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofMaster Closet
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing., Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Ceiling Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity/Frame: R-38/2x4
• Roof Deck. Wood Siding/sheathing/decking
R-38 Roof Attic1
Cathedral Ceilings
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.041
Roofing: Light Roof (Asphalt Shingle)
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-15 11:02:23
CERTf kTE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE HOD CF ?RF-01
Project Name: Vance Addn
Calculation Description: Title 24 Analysis
Calculation Date/Time: 11:01, Mon, Jul 15, 2019
Input File Name: Vance Addn LQ-Coyote Creek.ribdl6x
Page 7 of 10
• Inside Finish: Gypsum Board
• Sheathing/Insulation: R5 Sheathing
• Cavity/Frame: R-21 /2x6
R-21 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.048
Exterior Finish: 3 Coat Stucco
• Inside Finish: Gypsum Board
• Cavity/Frame: R-13/2x4
R-13 Wall
Interior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.092
Other Side Finish: Gypsum Board
• Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofCasita Zone
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
R 19 in 5-1/2 in.
Cavity/Frame: R-19 in 5-112 in. (R-18) /2x6
R-19 Wall (W. 1 9.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
cavity (R-18)
0.074
Exterior Finish: 3 Coat Stucco
• Inside Finish: Gypsum Board
• Cavity / Frame: no insul. / 2x4
R-0 Interior Wall
Interior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
none
0.277
Other Side Finish: Gypsum Board
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ft2)
Perimeter
(ft)
Edge Insul. R-value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Slab -on -Grade
Living Zone
2494
189
None
0.8
No
Existing
No
New Slab -on -Grade
Living Room Addition
122
31
None
0.8
No
New
No
Slab -on -Grade 2
Sleeping Zone
1483
189
None
0.8
No
Existing
No
Slab -on -Grade 3
Master Closet
172
40
None
0.8
No
Existing
No
Slab -on -Grade 4
Casita Zone
308
54
None
0.8
No
Existing
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Not Required
Not Required
Not Required
n/a
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-15 11:02:23
CERTXTE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: Vance Addn
Calculation Description: Title 24 Analysis
ff • 0
Calculation Date/Time: 11:01, Mon, Jul 15, 2019
Input File Name: Vance Addn LQ-Coyote Creek.ribdl6x
CF ")RF-01
Page 8 of 10
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
N
Status
Verified Existing
Condition
DHW Sys 1
DHW
Standard
DHW Heater 1
2
0
Existing
No
DHW Sys 3
DHW
Standard
DHW Heater 3
1
0
Existing
I No
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Input Rating /
Tank
Standby
Heater
Tank
Uniform Energy
Pilot /
Insulation
Loss /
First Hour
Tank Location
Element
Number
Volume
Factor / Energy
Thermal
R-value
Recovery
Rating /
NEEA Heat Pump
or Ambient
Name
Type
Tank Type
of Units
(gal)
Factor / Efficiency
Efficiency
(Int/Ext)
Eff
Flow Rate
Brand / Model
Condition
DHW Heater 1
Gas
Small Storage
2
50
0.61 EF
<= 75 kBtu/hr
0
n/a
n/a
n/a
n/a
DHW Heater 3
Gas
Small
Instantaneous
1
0
0.96 EF
<= 200 kBtu/hr
0
n/a
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
Distribution
Verified Existing
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Name
Status
Condition
HVAC-Livingl
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution
Existing
No
System 1
HVAC-Sleeping2
Other Heating and Cooling
System
Heating Component 2
Cooling Component 2
HVAC Fan 2
Air Distribution
Existing
No
System 2
HVAC-Casita3
Other Heating and Cooling
System
Heating Component 3
Cooling Component 3
HVAC Fan 3
Air Distribution
Existing
No
System 3
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-15 11:02:23
CERTI ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: Vance Addn
Calculation Description: Title 24 Analysis
HOD
Calculation Date/Time: 11:01, Mon, Jul 15, 2019
Input File Name: Vance Addn LQ-Coyote Creek.ribdl6x
CF ?RF-01
Page 9 of 10
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R-value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
Existing (not
System 1
(Ventilated and
specified)
6.0
Attic
Attic
None
Existing
No
n/a
Unventilated)
Air Distribution
Ducts located in attic
Existing (not
System 2
(Ventilated and
specified)
6.0
Attic
Attic
None
Existing
No
n/a
Unventilated)
Air Distribution
Ducts located in attic
Existing (not
System 3
(Ventilated and
specified)
8.0
Attic
Attic
None
Existing
No
n/a
Unventilated)
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
IAQ Recovery
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
0
0.25
Default
0
Not Required
PROJECT NOTES
QII - quality insulation installation- is addition only
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-15 11:02:23
CERTI ATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE
Project Name: Vance Addn
Calculation Description: Title 24 Analysis
HOD
Calculation Date/Time: 11:01, Mon, Jul 15, 2019
Input File Name: Vance Addn LQ-Coyote Creek.ribd16x
Cr 'RF-01
Page 10 of 10
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
%r 3:ce&t
Company:
Signature Date: U
Scott Design and Title 24, Inc,
7/15/2019
Address:
74-818 Velie Way, Suite #8
CEA/HERS Certification Identification (If applicable):
city/stat�A:m Desert, CA 92260
Phone: (760) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Douglas Vance
Responsible Designer Signature:
Company:
Douglas Vance, Owner
Date Signed:
Address:
79-045 Coyote Creek
License:
City/StatelZip:
La Quinta, CA 92253
Phone:
Registration Number: Registration Date/Tme: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-15 11:02:23
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Vance Residence Addition
Building Type 10 Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
711512019
Project Address
79-045 Coyote Creek La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
4,579
Addition
122
# of Units
1
INSULATION
Construction Ty2e
Area
Cavity ftz Special Features Status
Roof Wood Framed Attic
R 30 2,494
Existing
Wall Wood Framed
R 19 514
Existing
Wall Wood Framed
R 19 206
Existing
Wall Wood Framed
R 19 548
Existing
Wall Wood Framed
R 19 122
Existing
Slab Unheated Slab -on -Grade
- no insulation 2,494 Perim = 189'
Existing
Roof Wood Framed Attic
R 38 122
New
Wall Wood Framed
R 21 372 Add=R-5.0
New
FENESTRATION
Orientation Area ft2
I Total Area: 603 Glazing Percents w 17.5 %
U-Fac SHGC Overhang Sidefins
New/Altered Average U-Factor: 0.00
Exterior Shades Status
Rear (N) 70.0
0.710
0.60 none none
Bug Screen Existing
Right (E) 199.0
0.710
0.60 none none
Bug Screen Existing
Right (E) 285.0
0.710
0.60 16.0 none
Bug Screen Existing
Front (S) 174.0
0.710
0.60 none none
Bug Screen Existing
Lek (W) 74.4
0.710
0.60 none none
Bug Screen Existing
Skylight 0.4
0.300
0.30 none none
None Existing
Skylight 0.4
0.300
0.30 none none
None Existing
Skylight 0.4
0.300
0.30 none none
None Existing
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling Min. Eff
Thermostat Status
1 Central Furnace
80% TE
Split Air Conditioner 12.0 SEER
Setback Existing
1 Central Furnace
80% AFUE
Split Air Conditioner 16.0 SEER
Setback Existing
1 Central Furnace
80% AFUE
Split Air Conditioner 16.0 SEER
Setback Existing
HVAC DISTRIBUTION
Location Heating
Cooling Duct Location
Duct
R-Value Status
HVAC-Living Ducted
Ducted Attic
6.0 Existing
HVAC-Sleeping Ducted
Ducted Attic
6.0 Existing
HVAC-Casita Ducted
Ducted Attic
8.0 Existing
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution Status
EnergyPro 7.2 by Ener ySoft User Number: 6712
ID: Page 13 of 26
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Vance Residence Addition
Building Type
10 Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
711512019
Project Address
79-045 Coyote Creek La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
4,579
Addition
122
I # of Units
1
INSULATION
Construction Type
Cavity
Area
ftz Special Features Status
Slab Unheated Slab -on -Grade no insulation
122 Perim = 31' New
Demising Wood Framed no insulation
480 New
Roof Wood Framed Attic R 30
1,483 Existing
Wall Wood Framed R 19
338 Existing
Wall Wood Framed R 19
237 Existing
Wall Wood Framed R 19
282 Existing
Wall Wood Framed R 19
672 Existing
Slab Unheated Slab -on -Grade - no insulation
1,483 Perim = 189' Existing
FENESTRATION Total Area: 603 Glazing Percentage: 17.5 % New/Altered Average U-Factor. 0.00
Orientation Area ftz U-Fac SHGC Overhang Sidefins Exterior Shades Status
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling
Min. Eff Thermostat Status
HVAC DISTRIBUTION
Location Heating
Cooling
Duct
Duct Location R-Value Status
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EnejCqyPro 7.2 by EneCqvSoft User Number: 6712
ID: Pa a 14 of 26
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Vance Residence Addition
Building Type
m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
7/15/2019
Project Address
79-045 Coyote Creek La Quinta
California Energy Climate Zone Total Cond. Floor Area Addition
CA Climate Zone 15 4,579 122
# of Units
1
INSULATION
Construction Type
Cavity
Area
ft Special Features Status
Roof Wood Framed Attic R 36
77 Existing
Wall Wood Framed R 21
80 Add=R-5.0 Existing
Wall Wood Framed R 21
215 Add=R-5.0 Existing
Slab Unheated Slab -on -Grade -
no insulation
172 Perim = 40' Existing
Demising Wood Framed R 13
Roof Wood Framed Attic R 38
80 Existing
308 Existing
Wall Wood Framed R 19 in 5-112 h
123 Existing
Wall Wood Framed R 19 in 5-112 ii
133 Existing
FENESTRATION Total Area: 603 01 a zi ng Percents e: 17.5 New/Altered Average U-Factor. 0.00
Orientation Area ft2 U-Fac SHGC Overhang Sidefins Exterior Shades Status
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling
Min. Eff Thermostat Status
HVAC DISTRIBUTION
Location Heating
Cooling
Duct
Duct Location R-Value Status
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
Ener Pro 7.2 by Ener vSoft User Number: 6712
ID: Page 15 of 26
e 2016 Low -Rise Residential Mandatory Measures Summary
I § 150.0(h)3A:
Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any
dryer vent.
§ 150.0(h)3B:
Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by
manufacturer's instructions.
§ 150.00)1:
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must
be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a
§ 150.00)2A:
nominal diameter of 314 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter;
piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to
kitchen fixtures.'
§ 150.00)2B:
Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof
and non -crushable casing or sleeve:
§ 150.00)2C:
Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution
piping for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.'
§ 150.00)3:
Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by
§ 150.00)3A:
aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can
cause degradation of the material.
§ 150.00)3B:
Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a
Class I or Class II vapor retarder.
Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a
§ 150.0(n)1:
120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside
termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr.
§ 150.0(n)2:
Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification
Corporation SRCC or by a listing agency that is approved by the Executive Director.
Ducts and Fans Measures:
§ 110.8(d)3:
Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a
contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement.
CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC
§§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSIISMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or
a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing
§ 150.0(m)1
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than''% inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain
ducts. Ducts installed in cavities and support platforms must not be com ressed to cause reductions in the cross -sectional area of the ducts.'
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
§ 150.0(m)2:
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such tape is used in combination with mastic and draw bands.
§ 150.0(m)3:
Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
_
mastics, sealants, and other requirements specified for duct construction.
§ 150.0(m)7:
Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
automatic dampers.
§ 150.0(m)8:
Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
§ 150.0(m)9:
wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation.
§ 150.0(m)10:
Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)11
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 150.0 m111 and Reference Residential Appendix RA3.
Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet In length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,
pressure drop, and labeling requirements of § 150.0(m)12.
2016 Low -Rise Residential Mandatory Measures Summary
Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable
space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the
§ 150.0(m)13:
supply plenum. The space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy:5 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with
Reference Residential Appendix RAU. This applies to both single zone central forced air systems and every zone for zonally controlled central
forced airs stems.'
Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor
§150.0(o):
continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of
providing whole -building ventilation.
§ 150.0(o)1A:
Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.7.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
§ 110.4(a):
that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heatin .'
§ 110.4(b)l:
Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated
suction and return lines, or built-in or built-up connections to allow for future solar heating.
§ 110.4(b)2:
Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b)3:
Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
will allow all pumps to be set or programmed to run only during off-peak electric demand periods.
§ 110.5:
Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
150.0
§ (p)'
Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
rate, piping, filters, and valves.'
Lighting Measures:
§ 110.9:
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
of § 110.9.'
§ 110.9(e):
JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must
be certified to the Energy Commission according to Reference Joint Appendix JA8.
§ 150.0(k)lA:
Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or
§ 150.0(k)l B:
other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fanspeed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)l C:
labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for
elevated tem` O,aWF8 must be installed by final inspection in all recessed downli ht luminaires in ceilings.
§ 150.0(k)l D:
Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than
20 kHz.
Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no
§ 150.0(k)l E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled
by vacancy sensors.
§ 150.0(k)l F:
Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
must meet the applicable requirements of § 150.0(k).'
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply
§ 150.0(k)l G:
with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix
JA8.'
§ 150.0(k)l H:
Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E."
§ 150.0(k)2A:
Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B:
Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.'
§ 150.0(k)2C:
Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually
switched ON and OFF.
§ 150.0(k)2D:
Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with
150.0(k).
§ 150.0(k)2F:
Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it:
§ 150.0(k)2G:
functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of §
130.5(f): and meets all other requirements in § 150.0(k)2.
Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the
§ 150.0(k)2H:
following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of §
130.5 ; and all other requirements in § 150.0(k)2.
L_�§15(.O(k)21:
Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
provides the functionality of a dimmer according to J 110.9, and complies with all other applicable Loquirements in § 150.0(k)2.
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(k)2J:
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
I
be controlled by a vacancy sensor.
§ 150.0(k)2K:
Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with
Reference Joint Appendix JA8, except luminaires in closets less than 70 square feet and luminaires in hallways.'
§ 150.0(k)2L:
Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A:
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item
§ 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or
EMCS.
Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies,
§ 150.0(k)3B:
and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with
either 150.0(k)3A or with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)3C:
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by
§ 150.0(k)3B or § 150.0(k)3D must comply with the applicable requirements in §§ 110.9. 130.0. 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)3D:
Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more
vehicles per site must comply with the applicable requirements in §§ 110.9.130.0, 130.2. 130.4, 140.7, and 141.0.
§ 150.0(k)4:
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
power as determined according to § 130.0(c).
§ 150.0(k)5:
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
applicable requirements for nonresidential ,garages in §§ 110.9.130.0. 130.1, 130.4. 140.6. and 141.0.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A:
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be high efficacy luminaires and controlled by an occupant sensor.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must:
§ 150.0(k)6B
i. Comply with the applicable requirements in §§ 110.9, 130.0,130.1, 140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1:
application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the
requirements of § 110.10(b) through § 110.10(e).
§ 110.10(a)2:
Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d).
Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local
jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet
each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas
§ 110.10(b)1:
greater than 10,000 square feet.
For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250
square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang
of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less
than 15 percent of the total roof area of the building excluding any skylight area.'
§ 110.10(b)2:
Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.'
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)3B:
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone, measured in the vertical plane.'
§ 110.10(b)4:
Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof
dead load and roof live load must be clearly indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for
§ 110.10(c):
routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system.
§ 110.10(d).
Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
110.1 0c must be 2rovided to the occupant.
§ 110.10(e)1:
Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2:
breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or
main circuit location: and permanently marked as "For Future Solar Electric'.
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Date
Vance Residence Addition
7/15/2019
System Name
Floor Area
HVAC-Living
2,616
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
COIL
CFM
Total Room Loads 2.277
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation F 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING PEAK
COIL HTG.
PEAK
Sensible
Heating System
Sensible
Latent
CFM
Output perSystem
890,000
44,978
3,333
1,095
39.652
Total Output Btuh
890,000
0
output Btuh/s ft
340.2
3,069
2,287
Cooling System
0
0
Output perSystem
60,000
0
0
0
0
Total Output Btuh
60,000
0
3,069
51,117 3,333
0
Total Output Tons
5.0
2,287
Total Output Btuh/s ft
22.9
Total Output s ft/Ton
523.2
44,226
Air System
CFM perSystem
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
2,000
Exist. HVAC
45,789
5,360
890,000
Airflow cfm/s ft
0.76
Airflow cfm/Ton
400.0
Outside Air %
0.0 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
45,789
5,360
890,000
Jan 1 AM
Outside Air cfm/s ft
0.00
Note: values above given at ARI conditions
Aug 3 PM
HEATING SYSTEM PSYCHROMETRICS
Alrstrearrt Tem eratures at Time of Heating
Peak
26 OF
69 OF 105 IF 105 OF
P1- Q
HOutside
Air
0 cfm
Heating Coil Supply Fan
104 IF
2,000 cfm
ROOM
69 OF Return Fan
89 OF
70 OF
1,400 cfm
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling
Peak
112/78OF
76/62°F 55/54°F 55/54°F
fl
Outside Air
0 cfm
Cooling Coil Supply Fan
56 ! 54 OF
2,000 cfm
47.9 % ROOM
Return Fan
L -
76 / 62 OF
76 / 62 OF
75 / 62 IF
U `I f
1,400 cfm I
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Vance Residence Addition
Date
7/15/2019
System Name
HVAC-Sleeping
Floor Area
1,655
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,046
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 01
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
61,000
21,344
2,108
648
23,596
Total Output Btuh
61,000
0
Output Btuh/s ft
36.9
1,457
1,361
Cooling System
1 0
0
Output per System
49,000
0
0
0
0
Total Output Btuh
49,000
0
2,108
0
Total output Tons
4•1
1,457
1,361
Total Output Btuh/s ft
29.6
Total Output s ft/Ton
405.3
1 24,257
26.318
Air System
CFM per System
1,600
HVAC EQUIPMENT SELECTION
Airflow cfm
1,600
Carrier 24ANB748-58CVX080
37,095
4,487
61,000
Airflow cfm/s ft
0.97
Airflow cfm/Ton
391.8
Outside Air %
0.0 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
37,095
4,487
61,000
Jan 1 AM
Outside Air cfmis ft
0.00
Note: values above given at ARI conditions
Aug 3 PM
HEATING SYSTEM PSYCHROMETRICS
jAirstream Temperatures at Time of Heating
Peak
26 OF
Outside Air Ar
0 cfm
69 OF
69 OF 105 OF 105 OF
o
M
Heating Coil Supply Fan
1,600 cfm
ff f
104 IF
ROOM !
70 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling
Peak
112/78OF
Outside Air
0 cfm
76/62°F
76/62°F 55/54°F 55/54°F
►Cs7,�
Cooling Coil Supply Fan
1,600 cfm
56 / 54 OF
-- - -
47.6 % ROOM
75/62°F
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Vance Residence Addition
Date
7/15/2019
System Name
HVAC-Casita
Floor Area
308
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 389
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
51,000
7,990
392
177
6.502.
Total Output Btuh
51,000
0
Output Btuh/s ft
165.6
461
320
Cooling System
0
0
Output per System
18,000
0
0
0
0
Total Output Btuh
18,000
0
392
0
Total Out ut Tons
1.5
461
320
Total Output Btuh/s ft
58.4
Total Output s ft/Ton
205.3
1 8,912
7,141
Air System
CFM per System
600
HVAC EQUIPMENT SELECTION
Airflow cfm
600
Carrier 24ANB718/58CVX070
13,673
1,535
51,000
Airflow efm/s ft
1.95
Airflow cfrr►/Ton
400.0
Outside Air %
0•0 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
13,673
1,535
51,000
Jan 1 AM
Outside Air cfmis ft
0.00
Note: values above given at AFt1 conditions
Aug 3 PM
HEATING SYSTEM PSYCHROMETRICS
Airstream Tem eratures at Time of Heat€n
Peak
26 OF
Ilk IN
Outside Air
-4 P-
0 cfm
69 OF
69 OF 105 OF 105 OF
IN Q)
MSupply Fan
Heating Coil
600 cfm
U .I I I 4
r �
104 IF
ROOM
70 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling
Peak
112/78OF
Outside Air
0 cfm
76 / 62 IF
76/62°F 55/54°F 55/54°F
a
Cooling Coil Supply Fan
600 cfm
s
�-
56 / 54 OF
46.8 % � ROOMIN
75 / 62 IF
l
ZONE LOAD SUMMARY
Project Name
Vance Residence Addition
l Date
711512019
System Name
HVAC-Living
Floor Area
2,616
ZONE LOAD SUMMARY
ZONAL SYSTEM
COOLING PEAK
HEATING PEAK
ZONE NAME
SYSTEM NAME
Mult.
CFM
Sensible
Latent
Heating
OA CFM
Peak Hr
CFM
I Sensible
Latent
CFM
Sensible
Living Zone
1.0
0
Aug 3 PM
1 2,217
43,789
3,177
1,048
37,851
Living Room Addition
1.0
0
Aug 3 PM
60
1,188
155
47
1,801
TOTALS
0
0
01
0
Aug 3 PM
44,9781
3,333
1 39,652
(BLOCK LOAD
ZONE LOAD SUMMARY
Project Name
Vance Residence Addition
Date
711512019
System Name
HVAC-Sleeping
Floor Area
1,655
ZONE LOAD SUMMARY
ZONAL SYSTEM
COOLING PEAK
HEATING PEAK
ZONE NAME
SYSTEM NAME
Mult.
CFM
Sensible
Latent
Heating
OA CFM
Peak Hr
CFM
Sensible
Latent
CFM
Sensible
Sleeping Zone
1.0
0
Aug 3 PM
982
20,007
1,889
581
21,161
Master Closet
1.0
0
Aug 3 PM
66
1,337
219
67
2,435
TOTALS
0
0
0
0
Aug 3PM
21,344
2,108
23,596
(BLOCK LOAD
ZONE LOAD SUMMARY
Project Name
Vance Residence Addition
Date
7/15/2019
System Name
HVAC-Casita
Floor Area
308
ZONE LOAD SUMMARY
ZONAL SYSTEM
COOLING PEAK
HEATING PEAK
ZONE NAME
SYSTEM NAME
Mult.
CFM
Sensible
Latent
Heating
OA CFM
Peak Hr
CFM
Sensible
Latent
CFM
Sensible
Casita Zone
1.0
0
Aug 3 PM
389
7,990
392
177
6,502
TOTALS
0
01.
0
0
Aug 3 PM 1
7,990
3921
6,502
(BLOCK LOAD)