Loading...
BWFE2019-017278-495 CALLE TAMPICO C� 0 D 'iC[J LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Permit Type/Subtype: WALL/FENCE/CITY STANDARD/PRE-APPROVED Application Number: BWFE2019-0172 Property Address: 54575 AVENIDA VELASCO APN: 774283014 Application Description: STEMMER / 25OLF RETAINING AND 60LF GARDEN WALLS ON PL Property Zoning: Application Valuation: $9,000.00 Applicant: JOE W STEMMER 1R f__J 42215 WASHINGTON ST #355 PALM DESERT, CA 92211 SED1 2019 • C�iY oF'"f,'x� �u{ts�Pr LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 70001 of Division 3 of th Business an Professions Code, and my License is in full force and effect. License CI sss: License No.: 7 Date: 111�,1 Contractor: k/6 OWNER-BUILII&R DECLARATION hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/17/2019 Owner: JOE STEMMER 54575 AVENIDA VELASCO LA QUINTA, CA 92253 Contractor: JOE W STEMMER JR 42215 WASHINGTON ST #355 PALM DESERT, CA 92211 (760)880-3525 Llc. No.: 605857 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrie Policy Number:_ I certify that in the performance of the work for which this permit is issued, I shall t employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, i I sho Id become subject to the workers' compensation provisions of Section 370 of th Labor Cod , shall forthwith comply Ith those pllovisions. Date: 1 Applicant: WARNING: FAILURE TO SECURE WORKER UOMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and sta laws relating ul#dln8 construction, and reby authorize representatives of this ci y tWove - mentione grope y for inspection purposes. Date: Signature (Applicant or Agent} Date: '`9/17/2019 Application Number: BWFE2019-0172 Property Address: 54575 AVENIDA VELASCO APN: 774283014 Application Description: STEMMER / 250LF RETAINING AND 601-F GARDEN WALLS ON PL Property Zoning: Application Valuation: $9,000.00 Applicant: JOE W STEMMER JR 42215 WASHINGTON ST#355 PALM DESERT, CA 92211 Owner: JOE STEMMER 54575 AVENIDA VELASCO LA QUINTA, CA 92253 Contractor: JOE W STEMMER JR 42215 WASHINGTON ST #355 PALM DESERT, CA 92211 (760)880-3525 Llc. No.: 605857 Detail: 250LF OF 6' RETAINING AND 60LF OF 6' GARDEN WALL ON PROPERTY LINES, [ANGELUS 5-1.01-Q AND 5-1.61-Q, AND CITY STANDARD FOOTING OPTION 'B' SPECIFICATIONS] PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. THE AREA BETWEEN THE BACK OF CURB AND ANY FENCING SHALL BE LANDSCAPED, HAVE A SUITABLE PERMANENT IRRIGATION SYSTEM, AND BE CONTINUOUSLY MAINTAINED BY THE PROPERTY OWNER. 2016 CALIFORNIA BUILDING CODES. FINANCIAL INFORMATION DESCRIPTION ACCOUNT CITY AMOUNT RETAINING/COMBINATION WALL EA 50LF 101-0000-42400 0 $80.05 DESCRIPTION ACCOUNT CITY AMOUNT WALL/FENCE - EA ADDITIONAL 50 LF 101-0000-42404 0 $80.05 DESCRIPTION ACCOUNT QTY AMOUNT WALL/FENCE - FIRST 100 LF 101-0000-42404 0 $53.00 DESCRIPTION ACCOUNT QTY AMOUNT WALL/FENCE - FIRST 100 LF 101-0000-42404 0 $0.67 DESCRIPTION ACCOUNT QTY AMOUNT WALL/FENCE - FIRST 100 LF PC 101-0000-42600 0 $67.08 Total Paid for BLOCK WALL 2018: $280.85 DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 ta PERMIT # bW FE 2-01 1 1 PLAN LOCATION: Project Address: 54575 Ave Velasco Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: 774-283-014 150' 3' retaining/6' garden wall combo retaining wall ' 1' Applicant Name: Joe W. Stemmer 60' 6' garden wall Address: 42215 Washington St, #355 City, ST, Zip: Palm Desert, CA 92211 Telephone: 760-880-3525 Email: jstemmer@dc.rr.com Valuation of Projec_$9000 Contractor Name: Joe W. Stemmer Jr New SFD Construction: _ Address:42215 Washington St, #355 Conditioned Space City, St, Zip palm Desert, CA 92211 Garage Telephone: 760-880-3525 Patio/Porch Email: jstemmer@dc.rr.com Fire Sprinklers State Lie: 605857 City Bus Lie:763387 Arch/Eng Name: GLS Design Construction Type: new conventional Occupancy: SFR Address:74991 Joni Dr. Ste 9 Grading; City, St, Zip Palm Desert, CA 92211 Telephone: 760-880-3525 Bedrooms: Stories: # Units: Email: jstemmer@dc.rr.com State Lie: 605857 City Bus Lie:763387 Property Owner's Name: Contractor New Commercial / Tenant Improvements: Address: Total Building SF City, ST, Zip Construction Type: Occupancy: Telephone: Email' 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 BLOCK CO.. INC. Since 1946 ANGELUS BLOCK MASONRY FENCE WALL SYSTEM DESIGN CRITERIA: 1. DESIGN CRITERIA PER 2016 CBC 2. ALLOWABLE SOIL BEARING PRESSURE = 1500psf 3. ALLOWABLE SOIL PASSIVE PRESSURE = 150pcf 4. COEFFICIENT OF FRICTION = 0.25, COHESION = Opsf 5. CANTILEVER ACTIVE = 30pcf 6. MASONRY COMPRESSIVE STRENGTH, f'm = 1500psi. SPECIAL INSPECTION NOT REQUIRED PER CBC SECTION 1704.2, EXCEPTION 2, 'U' OCCUPANCY. 7. USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE PROJECT SPECIFIC SITE. NOTES: 1. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 GRADE 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER. CENTER VERTICAL BARS IN CELLS. 6' to 8' High Site Wall Eccentric Spread Footing C o 110mph Wit) Risk Category I 6" Wide CMU Vr I IUNAL WF STD. LADI 45 STD FOR JOINT REINF. COURSE, AT COURSE, ANC 2. JOINT REINFORCEMENT ("LADDER" TYPE) SHALL BE COLD —DRAWN STEEL WIRE CONFORMING TO ASTM A951. PROVIDE MINIMUM 6 INCH LAP SPLICES. 3. STRENGTH OF CONCRETE FOR FOOTINGS = 2500psi ® 28 DAYS, UNLESS 6" WIDE (NOS OTHERWISE REQUIRED BY SOILS REPORT. GROUT CELLS w/ REINF. 4. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS BLOCK PRECISION, SPLIT FACE, BURNISHED, OR SHOTBLAST, WITH OR WITHOUT MORTARLESS HEAD JOINTS (TONGUE —AND —GROOVE), OR ANGELUS BLOCK SLUMPSTONE SHALL BE USED. 5. MORTAR SHALL BE SPEC MIX TYPE S PREHLENDED MASONRY MORTAR AS MANUFACTURED BY E—Z MIX INC., CONFORMING TO PROPORTIONS AND 'X' BARS PER REQUIREMENTS OF ASTM C270, OR SPEC MIX IWR MASONRY MORTAR AS SCHEDULE MANUFACTURED BY E—Z MIX INC., CONFORMING TO PROPERTY CTR. OF WALI REQUIREMENTS OF ASTM C270. 6. GROUT SHALL CONFORM TO ASTM C476, WITH AN 8-11 INCH SLUMP, AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2000psi. 7. FIRST COURSE MAY BE WET —SET 1 1/2 INCHES MAX. WHILE CONCRETE DWLS. TO MA IS PLASTIC. VERT. REINF. 8. CONCRETE BLOCK SHALL BE LAID IN RUNNING BOND PATTERN WITH 24" MIN. VERTICAL CONTINUITY OF THE CELLS. 9. VERTICAL CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF F.G.- 40'-0"o.c. OR 20'-0"o.c. IF WALL IS TO BE STUCCO COATED OR MORTAR WASHED WET —SET FIR' ,0. GROUT ALL CELLS WITH REINFORCEMENT. COURSE 11. INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL FOOTING REINFORCING IS TIED IN PLACE. B. AFTER VERTICAL 2—#4 CONT. REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT. 12. FOR TYPICAL FOOTING STEP AND DRAINAGE BLOCK —OUT DETAILS SEE DETAIL SHEET S-5.1. CONT. CONC. 13. DO NOT PLACE FOOTING WITHIN 5'-0" OF A SLOPE MASONRY FENCE WALL SCHEDULE 'H' MAX. 'X' BARS 16' LONG CMU 18" LONG CMU 'B' MIN. 6'-0" 4348 o.c. 4054"o.c. 2-6 6'—B" 4040"o.c. 4045"o.c. 2'-9" 7_ 4" 4032"o.c. 4 6"o.c. 3'-0' 8'-0" 4024"o.c. I #4027'o.c- 3'-3" GHL INC. ARCHITECTURE , ENGINEERING 228 East eadillo Street Covina, CA 91723 T: 626.938,1595 F: 626.93&0485 _ v✓ww-gFlae.cam CITY OF LA QUINTA BUILDING DIVISION APPROVED FOR CONSTRUCTION BY: A,DATE: 09/21/2018 I'EK 5GHEUULE ESS�O q G III EXP. 9-30-20 1 �- C O IF FOF l»,F DATE SIGNED 9-10-18 S-1.1LQ #16-077 J ] n e J L AMBLO ANGELUS BLOCK MASONRY FENCE WALL SYSTEM DESIGN CRITERIA: 1. DESIGN CRITERIA PER 2016 CBC 2. ALLOWABLE SOIL BEARING PRESSURE = 1500psf 3. ALLOWABLE SOIL PASSIVE PRESSURE = 150pcf 4. COEFFICIENT OF FRICTION - 0.25, COHESION = Opsf 5. CANTILEVER ACTIVE - 30pcf 6. MASONRY COMPRESSIVE STRENGTH, fm = 1500psi. SPECIAL INSPECTION NOT REQUIRED PER CBC SECTION 1704.2, EXCEPTION 2, 'U' OCCUPANCY. 7. USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE PROJECT SPECIFIC SITE. 1. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 GRADE. 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER. CENTER VERTICAL BARS IN CELLS. 2. JOINT REINFORCEMENT ("LADDER" TYPE) SHALL BE COLD -DRAWN STEEL WIRE CONFORMING TO ASTM A951. PROVIDE MINIMUM 6 INCH LAP SPLICES. 3. STRENGTH OF CONCRETE FOR FOOTINGS = 2500psi 0 28 DAYS, UNLESS OTHERWISE REQUIRED BY SOILS REPORT. 4. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS BLOCK PRECISION, SPLIT FACE, BURNISHED, OR SHOTBLAST, WITH OR WITHOUT MORTARLESS HEAD JOINTS (TONGUE -AND -GROOVE), OR ANGELUS BLOCK SLUMPSTOME SHALL BE USED. 5. MORTAR SHALL BE SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS MANUFACTURED BY E-Z MIX INC., CONFORMING TO PROPORTIONS AND REQUIREMENTS OF ASTM C270, OR SPEC MIX IWR MASONRY MORTAR AS MANUFACTURED BY E-Z MIX INC., CONFORMING TO PROPERTY REQUIREMENTS OF ASTM C270. 6. GROUT SHALL CONFORM TO ASTM C476, WITH AN 8-11 INCH SLUMP, AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2000psi. 7. FIRST COURSE MAY BE WET -SET 1 1/2 INCHES MAX. WHILE CONCRETE IS PLASTIC. 8. CONCRETE BLOCK SHALL BE LAID IN RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS. 9. VERTICAL CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF 40'-0"o.c. OR 20'-0"o.c. IF WALL IS TO BE STUCCO COATED OR MORTAR WASHED 10. GROUT ALL CELLS WITH REINFORCEMENT 11. INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL FOOTING REINFORCING IS TIED IN PLACE. B. AFTER VERTICAL REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT. 12. FOR TYPICAL FOOTING STEP AND DRAINAGE BLOCK -OUT DETAILS SEE DETAIL SHEET S-5.1. 13. DO NOT PLACE FOOTING WITHIN 5'-0" OF A SLOPE MASONRY FENCE RETAINING WALL SCHEDULE ,H.I 'X' BARS ''Y' BARS 'B' MIN. 'C' MIN. 16" LONG CMU 16" LONG CMU 2-0" f403= 4®48 o.c. 2'-9 N/A 2'-8" 4032"o.c. 4248"o.c. 3'-0" N/A 3'-4" 4032"o.c. I #4048"o.c. 3'-5" N A 4'-0" 4032"o.c. I J4048"o.c. GHL INC. ARCHITECTURE - ENGINEERING 228 East eadillo Street i Covina, CA 91723 T: 626.938.1595 F: 626.938.0485 _ vvww ghI-ae Com 6' High Wall 2' to 4' Retaining Heel -in Footing C o 110mph Wit) Risk Category I 6"/8" Wide CMU OPTIONAL WALL CAP -\ 6 STD. LADDER TYPE #5 STD FOR SLUMPSTONE) JOINT REINF_ AT TOP COURSE, - AT FIRST COURSE, AND 24"o.c. AT FENCE 6" WIDE (NOM.) CMU w/ 'Y' BARS PER SCHEDULE 0 CTR. — OF WALL. GROUT CELLS w/ REINF. #4 HORIZ. 024"o.c. 0 RETAINING 4"0 SDR 35 PERF. PIPE w/ 1c.f. 3/4" GRAVEL WRAPPED IN MIRAFI 14ON FILTER FABRIC- - SLOPE TO DRAIN. WATERPROOF BACKSIDE OF RETAINING WALL 8" WIDE (NOM.) CMU FULLY GROUTED 'X' BARS PER SCHEDULE, LAP 24" MIN. F.G. - -- WET-SET FIRST ? COURSE #4 CONT. #4 CONT. ® 12"o.c. CONT. CONC. FTG. CONC. KEY LOADING 1. SEISMIC, 5% DAMPING ® 1 SECOND ACCELERATION Cs=0.33Wt. 2. FOUNDATION SIZES BASED ON MAXIMUM WIND OR SEISMIC LOADING. CITY OF LA QUINTA BUILDING DIVISION APPROVED FOR CONSTRUCTION BY: A DATE: 09/21/2018 'H' + 12" DISTANCE TO EDGE OF NEAREST ADJACENT FOUNDATION 0 OPTIONAL CHAMFER BACKFILL- WELL GRADED, CLEAN SANDS OR GRAVEL OR COMBINATION USC= GW,GP OR SW,SP 24" OUTSIDE FACE OF BLOCK TO I:) 4 OF VERT w x U In N M 0_1_r_L�t 3" C 12" 12" B' MIN. PER SCHEDULE Q+'OFESsio. G 'r �y C9 7 sin NO. 85 81 ; ♦c EXP. 9-30-20 Cl V 1 OF CA�1F DATE SIGNED 9-10-18 S-1.6LQ #16-077 FOOTING OPTION "A" A 6• N r• 8" pli , h 24" w: #4 HORIZONTAL REBAR (USF BOND BEAM BLOCK) '4 VERTICAL. REBAR AT 24" MAX. SPACING iEBAR IN CENTER OF CELL) HORIZONTAL RELIAR CONTI MAX. ABOVE TOP OF IRETAIi (USE BOND BEAM E31_OCK +RETAINING PORTION OF W� 8" BLOCK OUT ONLY CELLS WITH RIEW '.) - #4 HORIZONTAL RE13ARE 1T TOP OF RETAINING WALL (USE BOND BEAM BLOCK) STAINING PORTION OF WALL 8" BLOCK (SOLID GROUT ALL, CELLS) OMIT HEAD JOINTS FOR DRAINAGE - (FIRST COURS(-_ ONLY) • #4 HORIZONTAL REBARS r. I„ #4 REBAR - AT 24'' SPACING - - — --- Nvm-I 6•' MIr.4, HOOKS Al END5 ["OR OPTION -P") - FOOTING OPTION "B" 1 1 MAX ■ MAX 11_' 12" r 32" -- --- - THE FOLLOWING INSPECTIONS ARE REQUIRED: ALL FOOTINGS ADJACENT TO 1) FOOTING: EXCAVATION TRENCH CLEAN WITH STEEL IN PLACE AND SUPPORTED SLOPES TO BE AT LEAST 5' TO 3'' ABOVE AND AWAY FROM THE SURROUNDING EARTH/ DIRT. DAYLIGHT AS SHOWN BELOW, 2) REBAR/PRE-GROUT: BOND BEAM REBAR AND VERTICAL REBAR IN PLACE INSPECTION PRIOR TO PLACING GROUT. 3) FINAL: AFTER GROUT IS PLACED - PRIOR TO ANY DECORATIVE CAP PLACEMENT. NOTES: r f 1) FENCE HEIGHTS ARE REGULATED - CONSUI_TZONING REGULATIONS BOTTOM BEFORE BEGINNING CONSTRUCTION, OF °SIN 2) NO WATER COURSE OR NATURAL DRAINAGE SHALL BE FOOTIr,G OBSTRUCTED. 3) ALL REBAR TO BE ASTM SPEC. A61 5, GRADE 40 MINIMUM. "SEE PAGE 2 FOR ADDITIONAL INFORMATION` 4) ALL REBAR LAP SPLICES TO BE 24" MINIMUM, 5) ALL MASONRY UNITS TO BE ASTM C-90 GRADE N, WESTERN RIVERSIDE COUNTY CODE UNIFORMITY PROGRAM 6) NOT DESIGNED FOR SURCHARGE LOADS FROM VEHICLES OR STRUCTURES, i p Twitn�, ,r�iT QU&M i0/ `�Vi'�V DISCLAIMER; : ALTERNATE DESIGNS MAY BE POSSIBLE BLOCK WALL WHEN PROVIDED WITH AN ENGINEERED ANALYSIS, USE OF THIS STANDARD DESIGN �t ATOP 2' RETAINING WALL IS AT THE USER'S RISK AND CARRIES NO PI I[�N14 (760) 777-7125 78-495 CALLH TAMPICO IMPLIED OR INFERRED GUARANTEE AGAINST Lr1 [,]0I141'A, CIALIFC)NNIA 92"253 FAILURE OR DEFECTS. FAX (760) 777-7011 Iq/9/2o7•I DI,,Irr.1 IMGr,; 1 OF2 REBAR PLACEMENT ILLUSTRATION FOOTING OPTION B (SEEPAGE I FOR SPECIFIC REQUIREMENTS) (TYPICAL) FOR THE RETAfNING PORTION OF WALL 1 ALL CELLS TO BE GROUTED I ■. (TYPICAL) J FOR NON -RETAINING PORTION OF WALL ONLY CELLS AND BOND BEAM COURSES WITH REBAR TO BE GROUTED f '" (USE GROUT STOP MESH AS APPROPRIATE) •�J INN< jjj . •I �I -l► (TYPICAL) ALL REBAR SPLICES 24" MIN. OVERLAP (TYPICAL) FOOTING OPTION A `ram ALL REBAR SHALL HAVE A MINIMUM OF 3" CONCRETE COVER `• AT FOOTINGS DESIGN PARAMETERS. WESTERN RIVERSIDE COUNTY CODE UNIFORMITY PROGRAM ACTIVE SOIL PRESSURE (PSF) = 30 ,� P�GI PASSIVE SOIL BEARING (PSF) = 150*Alp COEFFICIENT OF FRICTION = 0.25 .I ALLOWABLE SOIL BEARING (PSF) = 1 500 �' BLOCK WALL WIND = 80 MPH, EXPOSURE C ? ` SEISMIC: ATOP 2' RETAINING WALL NA=1 .3. Nv= 1 .6, Z=O.A• SOIL PROFILE=SD 79-195 C'ATA.- TAM1°(CO I'I IUN1 (760) 777-7125 LrA OkIINTA, C•.AJ,II OWIIA 92253 FAX (760) 777-7011 a/o/zui•i cunrntuvrn•nrsvF;w1"n_nrura1r- ,'W.1 2ur2 5'-0' �C'z1' 5'-0' , ` 3' retaining combo/ 6' garden wall 00WC M LAlDW SHALL HOT EE MOM TNW V2 RICKS (M W LON R THHAH THE H161F5T FORK TOP OF TFE TH�SliOLD 100.50 FT F6 10030 FT F6 r roM P--L— on --� ! 1- — — — — — — — ! 1' retaining combo/ 6' garden wall I IL y ! RESIDENCECOUMM �5°OPE LAMMS SHALL NOT BE MOM THM ,2WMES% F. FLOOR 101.5 W LaOt TWIN THE TOP OF THE Tom F. GRADE 101.0 : Joe Stemmer Jr Const. a! !. 42215 Washington St. #355 i Palm Desert, CA 92211 I job: 54575 Ave Velasco, La Quinta, CA 3' retaining combo I 9 apn: 774-283-014 6' garden wall ! ! lot: 4 block 304 o SLOPE o 2d MAx r I I — SLOPE Mft%iow v "X HEIGHT MAX LAIDSCAPE VALVE LOCATHOH 1MFOMX hEA,HER� e 2 3 `f OMT MOM 12OW ORSMAR APPROVED P) MO ONCAREA N6 SLOPE ! c — — — — — — — ' — — 2dI MAXL UI$lT1E5 LOCATION roc p�o�ecG � + - ELMTRHOAL MAIN PM8 / hETFR 1 44 6 6lEHB4 PHOHEAVICAE E j — — — ....._-.._.._-. � 0 I POOL - 1 0 BY OTHERS �00 SF m .0 MET -y bA1C C 1 `r ! DRIVEWAY '=! �. 0OWETE FLOORING ETOT J 0 J 250 EAL. PROPME TANK r1J PJ AJI I00.04 FT FFa _-' :L 1 L, A_,) 10OD4 FT F6 PROVIDE OPEIIN6 AT BOTrOM FOR DRAINAGE ARABIAN JASMINE DEGOMPOESED 6 ZMITE 2' DES FINE DESERT GOLD 7 N (6ROUND COVER. ON EMIRNS) T IM rJ ' 5'-0' ' 1 SIDEWALK aE) FACE OF CURB - — - 0 FACE OF CURB X3V pE2` 4 +1- lD3fX1 �'MVEHAY APPROACH RfiGlNI�S OAT! M D G DEPA TM N OF PIIBLIG WORKS FCAI��ftA C DB ARTF�IP AVEN I DA VELASCO 5-0 , BUILDING DIV151QN REVIEWED FOR _CODE 'aWFE 2019 - o 1 72, 5LIS 7 S' AJD. V ELAsc 0 c-17Y