Loading...
PGA Maintenance Building Avenue 58Buena Engineers, Incl. AN EARTH SYSTEMS, INC. COMPANY 79-811 COUNTRY CLUB DRIVE, SUITE #4 • BERMUDA DUNES, CALIFORNIA 92201 • (619) 345-1588 November 19, 1987 Landmark Land Co. P.O. Box 1000 La Quinta, CA 92253 Project: PGA Maintenance Building Avenue 58 P.O. 28301 La Quinta, CA Subject: Report of Field Densities Parking Lot Entrance Subgrade B -14413-P12 87-11-763 On October 27, 1987, a representative of our firm performed density tests in the subgrade for the entrance to the parking lot at the above referenced project. Tests were performed at random locations in accordance with ASTM D 2922-81 and ASTM D 3017-78 Nuclear Density Test Procedure. Tests were performed as per authorization of Rueben of Landmark Land. The estimated locations of the tests are presented on the attached plan with their results being summarized on the attached test report sheet. A total of two (2) density tests were performed. Test results indicate that a minimum of ninety (90) percent of relative compaction has been obtained within the areas tested. The maximum density - optimum moisture were determined in the laboratory in accordance with ASTM D 1557-78, Method A or C. Test results are as follows: Soil Description Brown silty fine sand VENTURA (805) 642-6727 USCS Maximum Density -Optimum Moisture SM 119.2 pcf 10.8% LANCASTER (805) 948-7538 BAKERSFIELD SANTA BARBARA BERMUDA DUNES SAN LUIS OBISPO (805) 327-5150 (805) 966-9912 (619) 345-1588 (805) 544-6187 November 19, 1987 B -14413-P12 87-11-763 1. The project is located north of Avenue 58 and west of Madison Street, in the City of La Quinta. 2. Prior to our arrival at the site subgrade was cut and compacted. 3. The purpose of testing was to observe compliance with the minimum requirements of the City of La Quinta, California. The test results summarized in this report present the moisture and density only at the locations and depths tested on the specified date. The summarized field and laboratory tests were performed in accordance with engineering principles generally accepted at this time and location. No opinion is expressed as to the uniformity of the material or compaction. No guarantee or warranty of the contractor's work is made or implied. If there are any questions, please do not hesitate to contact this office. Respectfully submitted, BUENA ENGINEERS, INC. -P-D . Phillip D. Clanton PDC/FR/ms X-22 COMP Copies: 4 - Landmark Land Co. 2 - City of La Quinta 2 - PS file 1 - VTA file Revie ed and Approved Richard M. Beard Geotechnical Engineer BUENA ENGINEERS, INC GE 128 Exp. 12/31/89 9LH� 4F ULWSP Q!1k Buena Engineers, Inc, REPORT OF RELATIVE COMPACTIONS .lob No. B -14413-P12 CONTRACTOR DATE 11/19/87 Report NO 87-11-763 ADDRESS: JOB & LOCATION PGA 58th Ave. Maint. Bldg. TEST NO.DATE DESCRIPTION %MOISTURE DRY DENSITY RELATIVE MAXIMUM TESTED IN PLACE IN PLACE COMPACTION DENSIT• Subgrade 1 10/27/87 Per Plan 8.0 113.9 96 119.2 2 10/27/87 Per Plan 9.9 112.5 I 94 119.2 WE CERTIFY THAT THESE TESTS WERE PERFORMED IN CONFORMANCE WITH COPIES: BUENA ENGINEERS, INC,. ��1 E-101 9/1/87