BCOM2017-0028 Revision 1I BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Desert Vein & Vascular Institute TI
79440 Corporate Center Way, Suite 119
La Quinta, CA 92253
RECEIVED
DEC 0 8 2017
Project Designer:
Lawrence C.Reeves, L.P.
49-850 Jefferson St., Suite 130
Indio, CA 92201
(818) 425-0830
Report Prepared by
Jon d. Scott
Scott Design and Title 24,
74818 Velie Way Suite
Palm Desert, CA 9226
760-200-4780
Job Number:
Date:
CITY OF LA QUINTA 12/5/2017
COMMUNITY DEVELOPMENT
RomsION A
LCBUY OF LA QUINTA
c,BUILDING & SAFVEDPT•
PPROOR CONSTRUCTION
Arr
O�
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards.
This program developed by EnergySoft Software — www.energysoft.com.
I TABLE OF CONTENTS I
Cover Page
1
Table of Contents
2
Form PRF-01-E Certificate of Compliance
3
Form ENV-MM Envelope Mandatory Measures
22
Form ELC-01-E Electrical Power Distribution
23
HVAC System Heating and Cooling Loads Summary
29
Zone Load Summary
30
6
EnergyPro 7.2 by EnergySoft Job Number: ID: User Number: 6712 1
Project Name:
Tenant Improvement
NRCC-PRF-01-E
Page 1 of 19
Project Address:
79440 Corporate Center Way, Suite 119 La Quinta 92253
Calculation Date/Time:
14:56, Tue, Dec 05, 2017
Compliance Scope:
ExistingAlteration
Input File Name:
Desert Vein TI-La Quinta-TCZ-17.cibdl6x
A. PROJECT GENERAL INFORMATION
1.
Project Location (city)
La Quinta
8.
Standards Version
Compliance2016
2.
CA Zip Code
92253
9.
Compliance Software (version)
EnergyPro 7.2
3.
Climate Zone
15
10.
Weather File
PALM-SPRINGS-INTL_722868_CZ2010.epw
4.
Total Conditioned Floor Area in Scope
3,221 ftZ
11.
Building Orientation (deg)
(S) 180 deg
S.
Total Unconditioned Floor Area
0 ftZ
12.
Permitted Scope of Work
ExistingAlteration
6.
Total # of Stories (Habitable Above Grade)
1
13
Building Type(s)
Nonresidential
7.
Total # of dwelling units
0
14
Gas Type
NaturalGas
B. COMPLIANCE RESULTS FOR PERFORMANCE COMPONENTS (Annual TDV Energy Use, kBtu/ft Z-yr)
§ 140.1
BUILDING COMPLIES
1. Energy Component
2. Standard Design (TDV)
3. Proposed Design (TDV)
4. Compliance Margin (TDV)
5. Percent Better than Standard
Space Heating
0.32
0.34
-0.02
-6.3%
Space Cooling
208.95
206.02
2.93
1.4%
Indoor Fans
160.65
160.22
0.43
0.3%
Heat Rejection
-
-
'
Pumps & Misc.
-
-
-
Domestic Hot Water
5.11
16.97
-11.86
-232.1%
Indoor Lighting
78.27
67.02
11.25
14.4%
COMPLIANCE TOTAL
453.30
450.57
2.73
0.6%
Receptacle
110.83
110.83
0.0
0.0%
Process
-
--
Other Ltg
-
Process Motors
TOTAL
564.13
561.40
2.7
0.5%
CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-11092017-5160 Report Generated at: 2017-12-05 14:57:01
Protect Narne:
Tenant Improvement
NRCC-PRF-01-E
Page 2 of 19
Project Address:
79440 Corporate Center Way, Suite 119 La Quinta 92253
Calculation Date/Time:
14:56, Tue, Dec 05, 2017
Compliance Scope:
ExistingAlteration
Input File Name:
DesertVein TI-La Quinta-TCZ-17.cibdl6x
C. PRIORITY PLAN CHECK/ INSPECTION ITEMS (in order of highest to lowest TDV energy savings)
1st
Indoor Lighting: Check lighting
Compliance Margin By Energy Component (from Table B column 4)
Indoor Lighting
Space Cooling
Indoor Fans
Heat Rejection
Pumps & Misc.
Space Heating
Domestic Hot Water —
Penalty,o Energy Credit
2nd
Space Cooling: Check envelope and mechanical
3rd
Indoor Fans: Check envelope and mechanical
4th
Heat Rejection: Check envelope and mechanical
5th
Pumps & Misc.: Check mechanical
6th
Space Heating: Check envelope and mechanical
7th
Domestic Hot Water: Check mechanical-::-:
D. EXCEPTIONAL CONDITIONS
This project uses the Simplified Geometry Performance Modeling Approach which is not capable of modeling daylighting controls and assumes the prescriptive Secondary Daylit Control
requirements are met. PRESCRIPTIVE COMPLIANCE documentation (form NRCC-LTI-02-E) for the requirements of section 140.6(d) Automatic Daylighting Controls in Secondary Daylit Zones is
required.
This project includes Domestic Hot Water in the analysis. Please verify that Domestic Hot Water is included in the design for the permitted scope of work. I
E. HERS VERIFICATION
This Section Does Not Apply
F. ADDITIONAL REMARKS
None Provided
CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-11092017-5160 Report Generated at: 2017-12-05 14:57:01
Project Name:
Tenant Improvement
NRCC-PRF-01-E
Page 3 of 19
Project Address:
79440 Corporate Center Way, Suite 119 La Quinta 92253
Calculation Date/Time:
14:56, Tue, Dec 05, 2017
Compliance Scope:
ExistingAlteration
Input File Name:
Desert Vein TI-La Quinta-TCZ-17.cibdl6x
G. COMPLIANCE PATH & CERTIFICATE OF COMPLIANCE SUMMARY
Identify which building components use the performance or prescriptive path for compliance. "NA"-- not in project
For components that utilize the performance path, indicate the sheet number that includes mandatory notes on plans.
Building Component
Compliance Path
Compliance Forms (required for submittal)
Location of Mandatory Notes on
Plans
Envelope
❑
Performance
NRCC-PRF-ENV-DETAILS (section of the NRCC-PRF-01-E)
®
Prescriptive
NRCC-ENV-01 / 02 / 03 / 04 / 05 / 06-E
❑
NA
Mechanical
®
Performance
NRCC-PRF-MCH-DETAILS (section of the NRCC-PRF-01-E)
❑
Prescriptive
NRCC-MCH-01 / 02 / 03 / 04 / 05 / 06 / 07-E
❑
NA
Domestic Hot Water
®
Performance
NRCC-PRF-PLB-DETAILS (section of the NRCC-PRF-01-E)
❑
Prescriptive
NRCC-PLB-01-E
❑
NA
Lighting (Indoor Conditioned)
®
Performance
NRCC-PRF-LTI-DETAILS (section of the NRCC-PRF-01-E)
❑
Prescriptive
NRCC-LTI-01 / 02 / 03 / 04 / 05-E
❑
NA
Covered Process:
Commercial Kitchens
❑
Performance
S2 (section of the NRCC-PRF-01-E)
❑
Prescriptive
NRCC PRC 01/ 03-E
®
NA
Covered Process:
Computer Rooms
❑
Performance
S3 (section of the NRCC-PRF-01-E)
ElPrescriptive
NRCC-PRC-01/ 04 E
®
NA
Covered Process:
Laboratory Exhaust
❑
Performance
S4 (section of the NRCC-PRF-01-E)
ElPrescriptive
NRCC PRC 01/ 09 E
®
NA
CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-11092017-5160 Report Generated at: 2017-12-05 14:57:01
Project Name:
Tenant Improvement
NRCC-PRF-01-E
Page 4 of 19
Project Address:
79440 Corporate Center Way, Suite 119 La Quinta 92253
Calculation Date/Time:
14:56, Tue, Dec 05, 2017
Compliance Scope:
ExistingAlteration
Input File Name:
Desert Vein TI-La Quinta-TCZ-17.cibdl6x
G. COMPLIANCE PATH & CERTIFICATE OF COMPLIANCE SUMMARY
The following building components are only eligible for prescriptive compliance. Indicate which are
The following building components may have mandatory requirements per Part 6. Indicate
relevant to the project.
which are relevant to the project.
Yes NA
Prescriptive Requirement
Compliance Forms
Yes NA
Mandatory Requirement
Compliance Forms
Lighting (Indoor
Comm ssioning: §120.8
❑ ®
Unconditioned) §140.6
NRCC-LTI-01 / 02 / 03 / 04 / 05-E
❑ ®
Simple Systems
NRCC-CXR-01 / 02 / 03 / 05-E
❑ ®
Complex Systems
NRCC-CXR-01 / 02 / 04 / 05-E
❑ ®
Lighting (Outdoor) §140.7
NRCC-LTO-01 / 02 / 03-E
® ❑
Electrical: §130.5
NRCC-ELC-01-E
❑ ®
Lighting (Sign) §140.8
NRCC-LTS-01-E
❑ ®
Solar Ready: §110.10
NRCC-SRA-01 / 02-E
Covered Process: §120.6
NRCC-PRC-01-E
❑ ®
Pa -king Garage
NRCC-PRC-02-E
❑ ®
Solar Thermal Water
STH Ol E
❑ ®
Commercial Refrigeration
NRCC-PRC-05-E
Heating:NRCC
§140.5
❑ ®
Warehouse Refrigeration
NRCC-PRC-06/07/08-E
❑ ®
Compressed Air
NRCC-PRC-10-E
❑ ®
Process Boilers
NRCC-PRC-11-E
CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-11092017-5160 Report Generated at: 2017-12-05 14:57:01
Project Name:
Tenant Improvement
NRCC-PRF-01-E
Page 5 of 19
Project Address:
79440 Corporate Center Way, Suite 119 La Quinta 92253
Calculation Date/Time:
14:56, Tue, Dec 05, 2017
Compliance Scope:
ExistingAlte ration
Input File Name:
Desert Vein TI-La Quinta-TCZ-17.cibdl6x
H. CERTIFICATE OF INSTALLATION, CERTIFICATE OF ACCEPTANCE & CERTIFICATE OF VERIFICATION SUMMARY (NRCl/NRCA/NRCV) —
Documentation Author to indicate which Certificates must be submitted for the features to be recognized for compliance
(Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify).
See Tables G. and H. in MCH and LTI Details Sections for Acceptance Tests and forms by equipment.
Confirmed
Building Component
Compliance Forms (required for submittal)
Pass
Fail
Envelope
❑ NRCI-ENV-01-E - For all buildings
❑
❑
❑ NRCA-ENV-02-F- NFRC label verification for fenestration
❑
❑
Mechanical
® NRCI-MCH-01-E - For all buildings with Mechanical Systems
❑
❑
❑ NRCA-MCH-02-A-Outdoor Air
❑
❑
❑ NRCA-MCH-03-A—Constant Volume Single Zone HVAC
❑
❑
❑ NRCA-MCH-04-H- Air Distribution Duct Leakage
❑
❑
❑ NRCA-MCH-05-A- Air Economizer Controls
❑
❑
❑ NRCA-MCH-06-A- Demand Control Ventilation
❑
❑
❑ NRCA-MCH-07-A—Supply Fan Variable Flow Controls
❑
❑
❑ NRCA-MCH-08-A- Valve Leakage Test
❑
❑
❑ NRCA-MCH-09-A—Supply Water Temp Reset Controls
❑
❑
❑ NRCA-MCH-10-A- Hydronic System Variable Flow Controls
❑
❑
❑ NRCA-MCH-11-A—Auto Demand Shed Controls
❑
❑
❑ NRCA-MCH-12-A- Packaged Direct Expansion Units
❑
❑
❑ NRCA-MCH-13-A- Air Handling Units and Zone Terminal Units
❑
❑
❑ NRCA-MCH-14-A- Distributed Energy Storage
❑
❑
❑ NRCA-MCH-15-A— Thermal Energy Storage
❑
❑
❑ NRCA-MCH-16-A- Supply Air Temp Reset Controls
❑
❑
❑ NRCA-MCH-17-A—Condensate Water Temp Reset Controls
❑
❑
❑ NRCA-MCH-18-A- Energy Management Controls Systems
❑
❑
❑ NRCV-MCH-04-H- Duct Leakage Test
❑
❑
CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-11092017-5160 Report Generated at: 2017-12-05 14:57:01
Project Name:
Tenant Improvement
NRCC-PRF-01-E
Page 6 of 19
Project Address:
79440 Corporate Center Way, Suite 119 La Quinta 92253
Calculation Date/Time:
14:56, Tue, Dec 05, 2017
Compliance Scope:
ExistingAlteration
Input File Name:
Desert Vein TI-La Quinta-TCZ-17.cibdl6x
H. CERTIFICATE OF INSTALLATION, CERTIFICATE OF ACCEPTANCE & CERTIFICATE OF VERIFICATION SUMMARY (NRCl/NRCA/NRCV) —
Documentation Author to indicate which Certificates must be submitted for the features to be recognized for compliance
(Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify).
See Tables G. and H. in MCH and LTI Details Sections for Acceptance Tests and forms by equipment.
Confirmed
Building Component
Compliance Forms (required forsubmittal)
Pass
Fail
Plumbing
® NRCI-PLB-01-E - For all buildings with Plumbing Systems
❑
❑
❑ NRCI-PLB-02-E - required on central systems in high-rise residential, hotel/motel application.
❑
❑
❑ NRCI-PLB-03-E - Single dwelling unit systems in high-rise residential, hotel/motel application.
❑
❑
ElNRCI-PLB-21-E - HERS verified central systems in high-rise residential, hotel/motel application.
❑
El
❑ NRCI-PLB-22-E - HERS verified single dwelling unit systems in high-rise residential, hotel/motel application.
❑
❑
❑ NRCV-PLB-21-H- HERS verified central systems in high-rise residential, hotel/motel application.
❑
❑
❑ NRCV-PLB-22-H - HERS verified single dwelling unit systems in high-rise residential, hotel/motel application.
❑
❑
❑ NRCI-STH-01-E - Any solar water heating
❑
❑
Indoor Lighting
® NRCI-LTI-01-E - For all buildings
❑
❑
❑ NRCI-LTI-02-E - Lighting control system, or for an Energy Management Control System (EMCS)
❑
❑
❑ NRCI-LTI-03-E - Line -voltage track lighting integral current limiter, or for a supplementary overcurrent protection panel used to
energize only line -voltage track lighting
El
❑
❑ NRCI-LTI-04-E - Two interlocked systems serving an auditorium, a convention center, a conference room, or a theater
❑
❑
❑ NRCI-LTI-05-E -Lighting Control Credit Power Adjustment Factor (PAF)
❑
❑
❑ NRCI-LTI-06-E - Additional wattage installed in a video conferenc:ing studio
❑
❑
® NRCA-LTI-02-A - Occupancy sensors and automatic time switch controls.
❑
❑
® NRCA-LTI-03-A - Automatic daylighting controls
❑
❑
❑ NRCA-LTI-04-A - Demand responsive lighting controls
❑
❑
Outdoor Lighting
❑ NRCI-LTO-01-E — Outdoor Lighting
❑
❑
❑ NRCI-LTO-02-E- EMCS Lighting Control System
❑
❑
❑ NRCA-LTO-02-A - Outdoor Lighting Control
❑
❑
Sign Lighting
❑ NRCI-LTS-01-E—Sign Lighting
❑
❑
Electrical
® NRCI-ELC-01-E - Electrical Power Distribution
❑
❑
Photovoltaic
❑ NRCI-SPV-01-E Photovoltaic Systems
❑
❑
CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: 'NRCC-PRF-01-E-11092017-5160 Report Generated at: 2017-12-05 14:57:01
Project Name:
Tenant Improvement
NRCC-PRF-01-E
Page 7 of 19
Project Address:
79440 Corporate Center Way, Suite 119 La Quinta 92253
Calculation Date/Time:
14:56, Tue, Dec 05, 2017
Compliance Scope:
ExistingAlteration
Input File Name:
Desert Vein TI-La Quinta-TCZ-17.cibdl6x
H. CERTIFICATE OF INSTALLATION, CERTIFICATE OF ACCEPTANCE & CERTIFICATE OF VERIFICATION SUMMARY (NRCl/NRCA/NRCV) —
Documentation Author to indicate which Certificates must be submitted for the features to be recognized for compliance
(Retain copies and verify forms are completed and signed to post in field for Field Inspector to verify).
See Tables G. and H. in MCH and LTI Details Sections for Acceptance Tests and forms by equipment.
Confirmed
Building Component
Compliance Forms (required for submittal)
Pass
Fail
Covered Process
❑ NRCI-PRC-01-E Covered Processes
❑
❑
❑ NRCA-PRC-01-F- Compressed Air Systems
❑
❑
❑ NRCA-PRC-02-F- Kitchen Exhaust
❑
❑
❑ NRCA-PRC-03-F- Garage Exhaust
❑
❑
❑ NRCA-PRC-04-F- Refrigerated Warehouse- Evaporator Fan Motor Controls
❑
❑
❑ NRCA-PRC-05-F- Refrigerated Warehouse- Evaporative Condenser Controls
❑
❑
❑ NRCA-PRC-06-F- Refrigerated Warehouse- Air Cooled Condenser Controls
❑
❑
❑ NRCA-PRC-07F- Refrigerated Warehouse- Variable Speed Compressor
❑
❑
❑ NRCA-PRC-08-F- Electrical Resistance Underslab Heating System
❑
❑
I. ENVELOPE GENERAL INFORMATION (See NRCC-PRF-ENV-DETAILS for more information)
1.
Total Conditioned Floor Area
3,221 ft2
S.
Number of Floors Above Grade
1
Confirmed
2.
Total Unconditioned Floor Area
0 ft2
6.
Number of Floors Below Grade
0
3.
Addition Conditioned Floor Area
0 ft2
�
T
4.
Addition Unconditioned Floor Area
0 ft2
N U%
T.
7. Opaque Surfaces & Orientation
8. Total Gross Surface Area
9. Total Fenestration Area
10. Window to Wall Ratio
North Wall
468 ft2
75 ft2
16.0%
❑
❑
East Wall
738 ft2
0 ft2
00.0%
❑
❑
South Wall
468 ft2
105 ft2
22.4%
❑
❑
West Wall
738 ft2
165 ft2
22.4%
❑
❑
Total
2,412 ft2
345 ft2
14.3%
❑
❑
Roof
3,220 ft2
0 ft2
00.0%
❑
❑
CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-11092017-5160 Report Generated at: 2017-12-05 14:57:01
Project Name:
Tenant Improvement
NRCC-PRF-01-E
Page 8 of 19
Project Address:
79440 Corporate Center Way, Suite 119 La Quinta 92253
Calculation Date/Time:
14:56, Tue, Dec 05, 2017
Compliance Scope:
ExistingAlteration
Input File Name-
Desert Vein TI-La Quinta-TCZ-17.cibdl6x
J. FENESTRATION ASSEMBLY SUMMARY
§ 110.6
Confirmed
1.
2.
3.
4.
5.
6.
7.
8.
9.
Fenestration Assembly Name /
Fenestration Type / Product Type
Certification Methods
Assembly Method
Area ftz
Overall
Overall
Overall
d
N
v,
Tag or I.D.
/ Frame Type
U-factor
SHGC
VT
N
Vertical Fenestration
Existing Window
FixedWindow
Default Performance
Manufactured
345
0.71
0.73
0.77
E
❑
❑
MetalFraming
'Newly installed fenestration shall have a certified NFRC Label Certificate or use the CEC default tables found in Table 110.E-A and Table 110.E-B. Center of Glass (COG) values are for the glass -only, determined by the manufacturer and are shown for ease
of verification. Site -built fenestration values are calculated per Nonresidential Appendix NA6 and are used in the analysis.
Z Status: N -New, A -Altered, E- Existing
Taking compliance credit for fenestration shading devices? (if "Yes", see NRCC-PRF-ENV-DETAILS for more information) No
K. OPAQUE SURFACE ASSEMBLY SUMMARY
§ 120.7/ § 140.3
Confirmed
1.
2.
3.
4.
S. 6.
7.
S.
Surface Name
Surface Type
Area (ft2 )
Framing
Type
Cavity Continuous
R-Value R-Value
U-Factor / F-Factor
/ C-Factor
N
N
-
R-30 Roof10
Roof
3220
NA
0 30
U-Factor: 0.030
E
❑
❑
R-19 Wall (W.19.2x6.16)12
ExteriorWall
7.674
Wood
19 NA
U-Factor: 0.072
E
❑
❑
R-11 Wall Partition19
ExteriorWall
'738
Wood
11 NA
U-Factor: 0.110
E
❑
❑
Slab On Grade29
UndergroundFloor
3220
NA
0 NA
F-Factor: 0.730
E
❑
❑
2 Status: N - New, A -Altered, E- Existing
L. ROOFING PRODUCT SUMMARY
I § 140.3
Confirmed
1.
2.
3.
4.
S.
6.
7.
Product Density
Aged Solar
Thermal
Cool Roof
Roofing Product
4
Product Type
(lb/ftz)
Reflectance
Emiftance
SRI
Credit
Description
R-30 Roof10
5.323
0.08
0.75
NA
No
NA
❑
❑
CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-11092017-5160 Report Generated at: 2017-12-05 14:57:01
Project Name:
Tenant Improvement
NRCC-PRF-01-E
Page 9 of 19
Project Address:
79440 Corporate Center Way, Suite 119 La Quinta 92253
Calculation Date/Time:
14:56, Tue, Dec 05, 2017
Compliance Scope:
ExistingAlteration
Input File Name:
Desert Vein TI-La Quinta-TCZ-17.cibdl6x
M. HVAC SYSTEM SUMMARY (see NRCC-PRF-MCH-DETAILS for more information) § 110.1 / § 110.2
Dry System Equipment 1(Fan & Economizer info included below in Table N)
Confirmed
1.
2.
3.
4.
S.
6.
7.
8.
9.
10.
11.
pe
System Type
Total Heating
Supp Heat
Supp Heat
Total Cooling
Effi
Efficiency
Acceptance
Testing
,��,
v
°N'
T
01
Equip Name
Equip Type
(Simple or
Qty
Output
Source (Y/N)
Output
Output
Required? (Y/N)
*
N
'^
Complex 3)
(ketu/h)
(kBtuh)
(kBtu/h)
Cooling
Heating
4
AC 1- 4
SZHP (Split3Phase)
Simple
4
54
No
0
53
SEER-12.00
/ EER-10.00
HSPF-7.70
No
E
❑
❑
1 Dry System Equipment includesfurnaces, air handling units, heat pumps, etc.
Z Simple Systems must complete NRCC-CKR-03-E commissioning design review form
3 Complex Systems must complete NRCC-CXR-04-E commissioning design review form
4 A summary of which acceptance tests are applicable is provided in NRCC-PRF-MCH-DETAILS
5 Status: N - New, A -Altered, E- Existing
Wet System Equipment)
Pumps
Confirmed
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
Equip Name
Equip Type
Qty
Vol (gal)
Capacity
Rated Capacity
Rated
Efficiency
Standby Loss
Tank
Ext. R
Value
Qty
GPM
HP
(VSD
VSD
d
N
N
C
N
a
AO SMITH EUF-06*2
Storage
3
1 5.70
5
EF: 0.95
SBLF: NA
I NA
I
I NA
No
I N
❑
❑
1 Wet System Equipment includes boilers, chillers, cooling towers, water heaters, etc.
Z Status: N - New, A - Altered, E - Existing
Discrepancy between modeled and designed equipment sizing? (if "Yes", see Table F. "Additional Remarks" for an explanation) No
N. ECONOMIZER & FAN SYSTEMS SUMMARY'
§ 140.4
Confirmed
1.
2.
3.
4.
S.
Outside
Supply Fan
Return Fan
'a
Air
Economizer Type
N
T
01
TSP
TSP
Equip Name
(if present)
CFM
CFM
HP
BHP
(inch
Control
CFM
HP
BHP
(inch
Control
WC)
WC)
AC 1- 4
121
1800
1.000
1.000
1.76
ConstantVolume
NA
NA
NA
NA
NA
NoEconomizer
❑
❑
CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-11092017-5160 Report Generated at: 2017-12-05 14:57:01
Project Name
Tenant Improvement
NRCC-PRF-01-E
Page 13 of 19
Project Address:
79440 Corporate Center Way, Suite 119 La Quinta 92253
Calculation Date/Time:
14:56, Tue, Dec 05, 2017
Compliance Scope:
ExistingAlteration
Input File Name:
DesertVein TI-La Quinta-TCZ-17.cibdl6x
' Mechanical ventilation calculations and exhaust fans are included in the NRCC-PRF-MCH-DETAILS section
O. EQUIPMENT CONTROLS
I § 120.2
Confirmed
1.
2.
3•
v
N
T
m
-
Equip Name
Equip Type
Controls
No DCV Controls
No Economizer
AC 1- 4
SZHP
No Supply Air Temp. Control
❑
❑
No Optimum Start
No Evaporative Cooler
No Heat Recovery
Res DHW1- SHW
Service Hot Water, Primary Only
Fixed Temperature Control, No DDC
❑
No Heat Recovery
P. SYSTEM DISTRIBUTION SUMMARY I § 120.4/ § 140.4(1)
Dry System Distribution
Confirmed
1.
2.
3.
4.
5_
6.
Equip Name
Equip Type
Duct Leakage and
Sealing Required per
140.4(1)
Dud leakage will be
verified per NA1 and
NA2
Ducts
Status'
1A
'^
„
Insulation
R-Value
Location
AC1-4
SZHP
No
No
8
Unconditioned
E
❑
❑
I Status: N- New, E— Extstin rq
Does the Project Include Zonal Systems? (if "Yes", see NRCC-PRF-MCH-DETAILS for system information)
No
Does the Project Include a Solar Hot Water System? (if "Yes", see NRCC-PRF-MCH-DETAILS for system information)
No
Multifamily or Hotel/ Motel Occupancy? (if "Yes", see NRCC-PRF-MCH-DETAILS for DHW system information)
No
CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-11092017-5160 Report Generated at: 2017-12-05 14:57:01
Project Name:
Tenant Improvement
NRCC-PRF-01-E
Page 11 of 19
Project Address:
79440 Corporate Center Way, Suite 119 La Quinta 92253
Calculation Date/-I-ime:
14:56, Tue, Dec 05, 2017
Compliance Scope:
ExistingAlteration
Input File Name:
Desert Vein TI-La Quinta-TCZ-17.cibdl6x
Q. INDOOR CONDITIONED LIGHTING GENERAL INFO (see NRCC-PRF-LTI-DETAILS for more info)3
§ 140.6
Confirmed
1.
2.
3.
4.
S.
Occupancy Type 1
Conditioned Floor Area 2
Installed Lighting Power
Lighting Control Credits
Additional (Custom) Allowance
N
01
(ft2)
(Watts)
(Watts)
Area Category Footnotes
Tailored Method (Watts)
El
(Watts)
Medical and Clinical Care
3,221
3,309
0
0 1
0
❑
❑
Building Totals:
3,221
3,309
0
0
0
I See Table 140.6-C
2 See NRCC-LTI-01-E for unconditioned spaces
31-ighting information for existing spaces modeled is not included in the table
R. INDOOR CONDITIONED LIGHTING SCHEDULE (Adapted from NRCC-LTI-01-E)1
§ 130.0
Luminaire Schedule (includes all permanent installed lighting in
conditioned space, and portable lighting over 0.3 W/ft2 in
offices)
Installed Watts (Conditioned)
Confirmed
Name or Item Tag
Complete Luminaire Description (i.e.,
3-lamp fluorescent troffer, F32T8,
one dimmable electronic ballast)
Watts per luminaire
P
How Wattage is Determined
Total Number
Luminaires
Installed Watts
Pass
Fail
CEC Default
from NAB
According to
4130.0(c)
A
A-13.2 W Can
13
Yes
No
82
1,082
❑
❑
C
(3) 4 ft Fluorescent T8
79
Yes
No
6
474
❑
❑
E
E-Cove-3 W/F
3
Yes
No
151
453
❑
❑
H
6" LED Task Lighting
65
Yes
No
20
1,300
❑
❑
of lighting power densities were used in the compliance model Building Departments will need to check prescriptive forms for Luminalre Schedule details.
S1. COVERED PROCESS SUMMARY — ENCLOSED PARKING GARAGES § 140.9
This Section Does Not Apply
S2. COVERED PROCESS SUMMARY —COMMERCIAL KITCHENS § 140.9
This Section Does Not Apply
CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-11092017-5160 Report Generated at: 2017-12-05 14:57:01
Project Name:
Tenant Improvement
NRCC-PRF-01-E
Page 12 of 19
Project Address:
79440 Corporate Center Way, Suite 119 La Quinta 92253
Calculation Date/Time;
14:56, Tue, Dec 05, 2017
Compliance Scope:
ExistingAlteration
Input File Name:
Desert Vein TI-La Quinta-TCZ-17.cibdl6x
S3. COVERED PROCESS SUMMARY - COMPUTER ROOMS § 140.9
This Section Does Not Apply
S4. COVERED PROCESS SUMMARY - LABORATORY EXHAUSTS § 140.9
This Section Does Not Apply
T. UNMET LOAD HOURS
This Section Does Not Apply
U. ENERGY USE SUMMARY
Energy Component
Standard Design Site
(MWh)
Proposed Design Site
(MWh)
Margin
(MWh)
Standard Design Site
(MBtu)
Proposed Design Site
(MBtu)
Margin
(MBtu)
Space Heating
0.1
0.1
0.0
Space Cooling
23.0
22.7
0.3
Indoor Fans
24.1
24.0
0.1
Heat Rejection
--
--
--
Pumps & Misc.
--
Domestic Hot Water
--
2.4
--
11.4
Indoor Lighting
10.8
9.3
1.5
--
--
COMPLIANCE TOTAL
58.0
58.5
-0.5
11.4
0.0
--
Receptacle
14.7
14.7
0.0
10.0
10.0
0.0
Process
--
--
--
--
Other Ltg
-
-
-
Process Motors
-
--
TOTAL
72.7
73.2
-0.5
21.4
10.0
11.4
CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: IURCC-PRF-01-E-11092017-5160 Report Generated at: 2017-12-05 14:57:01
Project Name:
Tenant Improvement
NRCC-PRF-01-E
Page 13 of 19
Project Address:
79440 Corporate Center Way, Suite 119 La Quinta 92253
Calculation Date/Time:
14:56, Tue, Dec 05, 2017
Compliance Scope:
ExistingAlteration
Input File Name:
Desert Vein TI-La Quinta-TCZ-17.cibdl6x
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
§ 10-103
1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name: Jon d. Scott
Signature:
Company: Scott Design and Title 24, Inc, -�►ti� Jc
Address: 74818 Velie Way Suite 8
Signature Date:
City/State/Zip: Palm Desert CA 92260
CEA Identification (If applicable):
Phone: 760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am
1
licensed in the State of California as a civil engineer, mechanical engineer, electrical engineer, or I am a licensed architect.
1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by section 5537.2 or 6737.3 to sign this document as the person responsible for its
2
preparation; and that I am a licensed contractor performing this work.
1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to
3
Business and Professions Code Sections 5537, 5538 and 6737.1.
Responsible Envelope Designer Name: Lawrence C.Reeves
Signature: NOT IN SCOPE
Company: Lawrence C.Reeves, L.P.
Address: 49-850 Jefferson St., Suite 130
Date Signed:
City/State/Zip: Indio CA 92201
Declaration Statement Type:
Phone: (818) 425-0830
Title: License #:
Signature:
Responsible Lighting Designer Name: Lawrence C.Reeves
Company: Lawrence C.Reeves, L.P.
Address: 49-850 Jefferson St., Suite 130
Date Signed:
City/State/Zip: Indio CA92201
Declaration Statement Type:
Phone: (818) 425-0830
Title: License #:
Responsible Mechanical Designer Name: Tim Scott
ignature,
JC
Company: Scott Design and Title 24, Inc.
—TIa
Address: 77085 Michigan Drive
Date Signed: % - r
City/State/Zip: Palm Desert CA 92211
Declaration Statement Type:
Phone: (760) 200-4780
Title: License #:
CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-11092017-5160 Report Generated at: 2017-12-05 14:57:01
Project Name:
Tenant Improvement
NRCC-PRF-01-E
Page 14 of 19
Project Address:
79440 Corporate Center Way, Suite 119 La Quinta 92253
Calculation Date/Time:
14:56, Tue, Dec 05, 2017
Compliance Scope:
ExistingAlteration
Input File Name:
Desert Vein TI-La Quinta-TCZ-17.cibdl6x
NRCC-PRF-ENV-DETAILS -SECTION START
A. OPAQUE SURFACE ASSEMBLY DETAILS
Confirmed
1.
2.
:{.
4.
v
N
'^
-n
�
—
Surface Name
Surface Type
Description of Assembly Layers
Notes
Plywood - 5/8 in.
R-30 Roof10
Roof
Glass fiber batt - 10 in. R30 (CEC Default)
❑
❑
Air - Cavity - Wall Root' Ceiling - 4 in. or more
HB Part. Brd - 3/4 in.
Stucco - 7/8 in.
R-19 Wall (W.19.2x6.16)12
ExteriorWall
Vapor permeable felt - 1/8 in.Wood
El
❑
framed wall, 16in. OC, 5.5in., R-19
Gypsum Board - 1/2 in.
Stucco - 7/8 in.
R-11 Wall Partition19
ExteriorWall
Vapor permeable felt -1/8 in.
El
El
Wood framed wall, 16in. OC, 3.5in., R-11
Gypsum Board -1/2 in.
Slab Type = UnheatedSlabOnGrade
Slab On Grade29
UndergroundFloor
Insulation Orientation = None
❑
❑
Insulation R-Value = RO
B. OVERHANG DETAILS (Adapted from NRCC-ENV-02-E)
This Section Does Not Apply
C. OPAQUE DOOR SUMMARY
Confirmed
1.
2.
3.
4.
5,
6.
7.
Opaque Door Assembly Name
/ Tag or I.D.
Door Type
Certification Method
Operation
Area
Overall
U-factor
Status 1
Pass
Fail
Insulated Metal Door17
Meta IUninsulatedSingleLayerpoor
DefaultPerformance
Swinging
20
0.079
E
❑
❑
1 Status: N - New, A —Altered, E— Existing
CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: IVRCC-PRF-01-E-11092017-5160 Report Generated at: 2017-12-05 14:57:01
Project Name:
Tenant Improvement
NRCC-PRF-01-E
Page 15 of 19
Project Address:
79440 Corporate Center Way, Suite 119 La Quinta 92253
Calculation Date/Time:
14:56, Tue, Dec 05, 2017
Compliance Scope
ExistingAlteration
Input File Name:
Desert Vein TI-La Quinta-TCZ-17.cibdl6x
NRCC-PRF-MCH-DETAILS -SECTION START
A. MECHANICAL VENTILATION AND REHEAT (Adapted from 2016-NRCC-MCH-03-E)
Confirmed
1. DESIGN AIR FLOWS
2. VENTILATION (§
120.1)
D
H
�_
p
m
z
A
m
D
O
I
Z
G1
Z
D Z
Z
�'
D�D
X_
�+
G
G
O
Z
G
Z
a
f.
G1
y
A
A�
-n
O�
rLC
-n
O�
�C
n
z
1
O
Z
nG
3Z
^'
1
Z
<
m
Am
-n
CONDITIONED
f\1
Tn
On
�y
OC
�_
��o+_
O
m
Tm
��
C
$
y
D
rz
fOi
A-C�'
Vn
y
ZONE NAME
v�
C
3A
�A
D�
n
Dm
O
G
v
Nz
O
m m
�—�
n
-A
<
Z
o
z
nj
`�3
„�
��
m
3
n
m
-n
o
z
o
0
`F
Zm
T
Z
�3
Z<
.r61
Z0
Z
G
D
w
O'
�^
r0
n
_
r-
a
a
a
a
O
F
-n
o
C
.
70
m
Z
9
`
LM
1-Tenant
AC 1- 4
1,800
NA
NA
NA
NA
N
AC 1- 4
3,221
NA
16.11
30-00
483
483
NA
N
NA
❑
❑
Improvement
TOTAL
3,221
NA
NA
I NA
NA
❑
❑
B. ZONAL SYSTEM AND TERMINAL UNIT SUMMARY
§ 140.4
1.
2.
3.
4.
5.
6.
7.
8.
Confirmed
Rated Capacity
Airflow (cfm)
Fan
(kBtuh)
-
System ID
System Type
Qty
Economizer
Zone Name
_
Heating
Cooling
Design
Min.
Ratio
BHP
Cycles
FCM
Motor
1-Tenant
Uncontrolled
4
NA
NA
NA
1-Tenant Improvement
1800
NA
NA
NA
NA
❑
El❑
Improvement Trm
C. EXHAUST FAN SUMMARY
This Section Does Not Apply
CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-11092017-5160 Report Generated at: 2017-12-05 14:57:01
Project Name:
Tenant Improvement
NRCC-PRF-01-E
Page 16 of 19
Project Address:
79440 Corporate Center Way, Suite 119 La Quinta 92253
Calculation Date/Time
14:56, Tue, Dec 05, 2017
Compliance Scope:
ExistingAlteration
Input File Name:
Desert Vein TI-La Quinta-TCZ-17.cibdl6x
D. DHW EQUIPMENT SUMMARY — (Adapted from NRCC-PLB-01)
§ 110.3
Confirmed
1.
2.
3.
4.
S.
6.
7.
8.
9.
10.
11.
DHW Name
Heater
Tank Type
Qty
Tank Vol
Rated Input
Efficiency
Tank
Insulation
Standby Loss
Heat Pump
Tank Location
or Ambient
N
Element Type
yp
al
(gal)
(kBtu/h)
R-value
Fraction
Type
ondition
Condition
AO SMITH
06
Electricity
Storage
3
5.70
5
EF: 0.95
NA
SBL=: NA
NA
NAEUF-
❑
❑
E. MULTI -FAMILY CENTRAL DHW SYSTEM DETAILS
This Section Does Not Apply
F. SOLAR HOT WATER HEATING SUMMARY (Adapted from NRCC-STH-01)
This Section Does Not Apply
G. MECHANICAL HVAC ACCEPTANCE TESTS & FORMS (Adapted from 2016-NRCC-MCH-014)
§ RA4
Declaration of Required Acceptance Certificates (NRCA) — Acceptance Certificates that may be submitted. (Retain copies and verify forms are completed and signed to post in field for Field
Inspector to verify).
Test Description
n
x
n
x
n
x
n
x
n
x
n
x
n
x
n
x
n
x
n
x
n
x
n
x
n
x
n
x
n
x
n
x
n
x
Confirmed
6
N
6
W
6
A.
6
V1
6
a%
6
V
pp
00
o
w
4
O
4
F+
4.
N
4
W
4
A
r
w
r
M
r
V
r
00
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
3
o
v,
v
0
v
o
Equipment
3
<
z
Requiring
# of
o
rev
o
v
a'
v
<
�_rD
n ,<,
o
n o
o
o
T
ni v
v'
`�°
v
D
m m
m
n
-n
°o
m
.'
n
a
fD
°;
a,
.�. a
o
x
D<
m
o m
v01
of
Testing or
units
v
n
<
;; r�
o
o Q
x
ro o
n N
ro
3
'
Ln
Verification
D
�
<
�
„
Ln
D
o
N
o
rro
v
o
'"
!p
m
M
Res DHW1
1
—
—
❑
❑
SHW
AC1-4
4
-
-
❑
❑
CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: IVRCC-PRF-01-E-11092017-5160 Report Generated at: 2017-12-0514:57:01
Project Name:
Tenant Improvement
NRCC-PRF-01-E
Page 17 of 19
Project Address:
79440 Corporate Center Way, Suite 119 La Quinta 92253
Calculation Date/Time:
14:56, Tue, Dec 05, 2017
Compliance Scope:
ExistingAlteration
Input File Name:
Desert Vein TI-La Quinta-TCZ-17.cibdl6x
H. EVAPORATIVE COOLER SUMMARY
This Section Does Not Apply
NRCC-PRF-LTI-DETAILS -SECTION START
A. INDOOR CONDITIONED LIGHTING CONTROL CREDITS (Adapted from NRCC-LTI-02-E)
§ 140.6
Lighting Control Credits Schedule (includes all lighting controls installed in conditioned space for
Control Credit Calculation
Confirmed
compliance credit per §140.6(a)2 and Table 140.6-A)
V If Acceptance
Location in
Occupancy Type (must meet
Type/Description of Lighting
Watts of
Power
Control Credit
Test Required
Building
requirements of Table 140.6 A)
Control (i.e., partial on occupancy
# of Units
Controlled
Adjustment
Watts
Pass
Fail
sensor, manual dimming, etc.)
Lighting
Factor
S-1-Tenant
Medical and Clinical Care
none specified -
1
0.00
0
❑
❑
Improvement
S-1-Tenant
Medical and Clinical Care
-none specified -
1
0.00
0
❑
Improvement
S-1-Tenant
Medical and Clinical Care
-none specified -
1
0.00
0
El
El
Improvement
S-1-Tenant
Medical and Clinical Care
-none specified -
1
0.00
0
El
Improvement
B. INDOOR CONDITIONED LIGHTING MANDATORY LIGHTING CONTROLS (Adapted from NRCC-LTI-02-E) I § 130.1 I
This Section Does Not Apply
i130.1(o) = Manual area controls; §I30.0(6) = Multi Level; §T30.1(c)= Auto
D. GENERAL LIGHTING POWER (Adapted from NRCC-LTI-04-E) I § 140.6-D
This Section Does Not Apply
CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-11092017-5160 Report Generated at: 2017-12-05 14:57:01
Project Name:
Tenant Improvement
NRCC-PRF-01-E
Page 13 of 19
Project Address:
79440 Corporate Center Way, Suite 119 La Quinta 92253
Calculation Date/Time:
14:56, Tue, Dec 05, 2017
Compliance Scope:
ExistingAlteration
Input File Name:
Desert Vein TI-La Quinta-TCZ-17.cibdl6x
E. GENERAL LIGHTING FROM SPECIAL FUNCTION AREAS (Adapted from NRCC-LTI-04-E)
§ 140.6(c) 3H
Room Number
PrimaryFunction Area
Illuminance Value
(LUX)
Room Cavity Ratio
(Table G)
Allowed LPD
z
Floor Area (ft)
Allowed Watts
Confirmed
Pass
Fail
NA
NA
NA
NA
NA
NA
NA
❑
❑
ed —nod for Sper al FGlTctioa Areas Is not currently implemented
F. ROOM CAVITY RATIO (Adapted from NRCC-LTI-04-E)
Rectangular Spaces
Room Number
Task/Activity Description
Room Length (ft)
Room Width (ft)
Room Cavity Height (ft)
RCR
Confirmed
Pass
Fail
NA
NA
NA
NA
NA
NA
❑
❑
Non -Rectangular Spaces
This Section Does Not Apply
rudte. Arc uppikaare spaces are hsted under the Non-nectongurar spaces tavi.
G. ADDITIONAL "USE IT OR LOSE IT" (Adapted from NRCC-LTI-04-E)
1.
2.
3.
4.
Allowed Watts
Confirmed
Wall Display
Combined Floor Display and Task
Lighting
Combined Ornamental and Special
Effects Lighting
Very Valuable Merchandise
v
N
T
m
0
0
0
0
0
❑
❑
S. Wall Display
This Section Does Not Apply
6. Floor Display and Task Lighting
This Section Does Not Apply
7. Combined Ornamental and Special Effects Lighting
This Section Does Not Apply
CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: r4RCC-PRF-01-E-11092017-5160 Report Generated at: 2017-12-05 14:57:01
Project Name:
Tenant Improvement NRCC-PRF-01-E
Page 19 of 19
Project Address:
79440 Corporate Center Way, Suite 119 La Quinta 92253 Calculation Date/Time:
14:56, Tue, Dec 05, 2017
Compliance Scope:
ExistingAlteration Input File Name:
Desert Vein TI-La Quinta-TCZ-17.cibdl6x
8. Very Valuable Merchandise
This Section Does Not Apply
H. INDOOR & OUTDOOR LIGHTING ACCEPTANCE TESTS & FORMS (Adapted from NRCC-LTI-01-E and NRCC-LTO-01-E)
I § 130.4
Declaration of Required Acceptance Certificates (NRCA) —Acceptance Certificates that must be verified in the field. (Retain copies and verify forms are completed and signed to post in field for
Field Inspector to verify).
Test Description
Indoor
Outdoor
Confirmed
NRCA-LTI-02-A
NRCA-LTI-03-A
NRCA-LTI-04-A
NRCA-LTO-02-A
Equipment Requiring
Testing or Verification
# of units
Occ Sensors / Auto Time
Switch
Auto Daylight
Demand Responsive
Outdoor Controls
oVi
-
Occupant Sensors
0
®
❑
❑
❑
❑
❑
Automatic Time Switch
0
®
❑
❑
❑
❑
❑
Automatic Daylighting
0
❑
®
❑
❑
❑
❑
Demand Responsive
0
❑
❑
❑
❑
❑
❑
Outdoor Controls
0
❑
❑
❑
❑
❑
❑
CA Building Energy Efficiency Standards- 2016 Nonresidential Compliance Report Version: NRCC-PRF-01-E-11092017-5160 Report Generated at: 2017-12-05 14:57:01
ENVELOPE MANDATORY MEASURES: NONRESIDENTIAL ENV-MM
Project Name
Date
Desert Vein & Vascular Institute TI
1215,12017
_DESCRIPTION
Building
Envelope Measures:
§110.8(a):
Installed insulating material shall have been certified by the manufacturer to comply with the California Quality
Standards for insulating material, Title 20 Chapter 4, Article 3.
§110.8(c):
All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of
Sections 2602 and 707 of Title 24, Part 2.
§110.8(g):
Heated slab floors shall be insulated according to the requirements in Table 110.8-A.
§110.7(a):
All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed,
weatherstripped or otherwise sealed.
Manufactured fenestration products and exterior doors shall have air infiltration rates not exceeding 0.3 cfm/ft.2 of
§110.6(a):
window area, 0.3 cfm/ft.Z of door area for residential doors, 0.3 cfm/ft.z of door area for nonresidential single doors
(swinging and sliding), and 1.0 cfm/ft.z for nonresidential double doors (swinging),
§110.6(a):
Fenestration U-factor shall be rated in accordance with NFRC 100, or the applicable default U-factor.
§110.6(a)
Fenestration SHGC shall be rated in accordance with NFRC 200, or NFRC 100 for site -built fenestration, or the
applicable default SHGC.
§110.6(b):
Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be
weatherstripped (except for unframed glass doors and fire doors).
The opaque portions of the roof/ceiling that separates conditioned spaces from unconditioned spaces or ambient air
shall meet the applicable U-Factor requirements as follows:
§120.7(a):
Metal Building- The weighted average U-factor of the roof assembly shall not exceed 0.098.
Wood Framed and Others- The weighted average U-factor of the roof assembly shall not exceed 0.075.
The opaque portions of walls that separate conditioned spaces from unconditioned spaces or ambient air shall meet the
applicable U-factor as follows:
Metal Building- The weighted average U-factor of the wall assembly shall not exceed 0.113.
Metal Framed- The weighted average U-factor of the wall assembly shall not exceed 0.151.
Light Mass Walls- A 6 inch or greater Hollow Core Concrete Masonry Unit shall have a U-factor not to exceed 0.440.
§120.7(b):
Heavy Mass Walls- An 8 inch or greater Hollow Core Concrete Masonry Unit shall have a U-factor not to exceed
0.690.
Wood Framed and Others- The weighted average U-factor of the wall assembly shall not exceed 0.110.
Spandrel Panels and Opaque Curtain Wall- The weighted average U-factor of the spandrel panels and opaque
curtain wall assembly shall not exceed 0.280.
Demising Walls-. The opaque portions of framed demising walls shall meet the requirements of Item A or B below:
A. Wood framed walls shall be insulated to meet a U-factor not greater than 0.099.
B. Metal Framed walls shall be insulated to meet a U-factor not greater than 0.151.
The opaque portions of floors and soffits that separate conditioned spaces from unconditioned spaces or ambient air
shall meet the applicable U-Factor requirements as follows:
§120.7(c):
Raised Mass Floors- Shall have a minimum of 3 inches of lightweight concrete over a metal deck or the weighted
average U-factor of the floor assembly shall not exceed 0.269.
Other Floors -The weighted avers a U-factor of the floor assembly shall not exceed 0.071.
STATE OF CALIFORNIA
Electrical Power Distribution
CEC-NRCC-ELC-01-E (Revised 01/16)
CALIFORNIA ENERGY COMMISSION Oe
CERTIFICATE OF COMPLIANCE NRCC-ELC-01-E
Electrical Power Distribution (Page 1 of 6)
Project Name: Date Prepared:
Desert Vein &Vascular Institute TI 12/5I2017
General Information
Project Address:
79440 Corporate Center Way, Suite 119
Climate Zone:
15
3o2ndi ioned Floor Area:
Unconditioned Floor Area:
0
Building Type: G] Nonresidential
❑ Schools
❑ High -Rise Residential
❑ Relocatable Public Schools
❑ Hotel/Motel
Phase of Construction: ❑ New Construction
❑ Addition
® Alteration
In the table below identify all applicable construction documents that specify the requirements for the scope of responsibility
reported by this certificate. Use additional pages as needed to list all construction documents related to compliance of Section 130.5.
Document Number
Document Title / Descriptions
(include description information for Table or
Schedule if it contains compliance information)
Document Sheet #
or Page #
Indicate which
subsection of
Section 130.5 is
related to the
document (e.g.
130.5(a) for
service electrical
metering)
1
CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016
STATE OF CALIFORNIA
Electrical Power Distribution 3
CEC-NRCC-ELC-01-E (Ravrm d 01/16) CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-ELC-01-E
Electrical Power Distribution (Page 2 of 6)
Project Name: Date Prepared:
Desert Vein & Vascular Institute TI 12/5/2017
Document Title / Descriptions Applicable
Document Sheet #
Document Number (include description information for Table or or Page # subsection of
Schedule if it contains compliance information) Section 130.5
CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016
STATE OF CALIFORNIA
Electrical Power Distribution
CEC-NRCC-ELC-01-E (Revised 01/16)
CALIFORNIA ENERGY COMMISSION 4Z
CERTIFICATE OF COMPLIANCE NRCC-ELC-01-E
Electrical Power Distribution (Page 3 of 6)
Project Name: Desert Vein & Vascular Institute TI Date Prepared: 12/5/2017
A. Service Electrical Metering
Check one of the three boxes below if the electrical power distribution system is in compliance with Section 130.5(a).
❑ For newly installed electrical service in newly constructed buildings, Service Electrical Metering is required according to Section 130.5(a). Fill out
Column 1 thru 6 of table below.
jl;� For new or replacement electrical service equipment in existing buildings, Service Electrical Metering is required according to Section 141.0(b)2Pi.
Fill out Column 1 thru 6 of table below.
❑ EXCEPTION to Electrical Service Metering: Service or feeder for which the utility company provides a metering system that indicates instantaneous
kW demand and kWh for a utility -defined period. Fill out Column 1, 2 and 6 of table below with the compliance information.
Fill out a separate line for each electrical service that is connected to the building. If additional table space is needed for electrical service information,
submit additional page with the information.
Electrical
Metering Capabilities
Exception to
Electrical Service Schedule
Service
(check all that are present)
130.5(a)
Field Inspector
Rating
01
02
03
04
05
06
07
08
N
O
Y
N
L
CU
OD
C
+
r0 3
eo m o
v o
v v
Check that the
C t Y
+�
U Y
`o
Y m 4= OJ
a)a
D. W
r y
h
>
metering complies
Electrical Service
m
u
12 ° v
3
Designation/Location/Description
kVA
_�
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
u
CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016
STATE OF CALIFORNIA
Electrical Power Distribution
CEC-NRCC-ELC-01-E (Revised 01/16) CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-ELC-01-E
Electrical Power Distribution (Page 4 of 6)
Project Name. Desert Vein & Vascular Institute TI Date Prepared. 12/5/2017
B. Separation of Electrical Circuits for Electrical Energy Monitoring
Check all boxes below if the electrical power distribution system is in compliance with Section 130.5(b).
EX The electrical power distribution system meets the separation of electrical circuits for electrical energy monitoring requirement of Section
130.5(b). The electrical power distribution systems is designed so that measurement devices can monitor the electrical energy usage of load
types according to TABLE 130.5-B.
L$ Describe the electrical power distribution system installed and the compliance method chosen in meeting the requirement of Section
130.5(b). Use the space below to include the information. Examples of compliance methods are detailed in Nonresidential Compliance
Manual Chapter 8.
Fill out Column 1 thru 3 with the compliance information.
General information
Electrical Power Distribution System information and Method of
Electrical Service Enforcement
compliance
Rating Agency
I
01
02
03
04
Electrical Service
Designation/Location/Descrip
Describe the electrical power distribution system installed and the
WA
Check that the
tion
compliance method used.
system complies
0
Field Inspector Notes:
CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016
STATE OF CALIFORNIA
Electrical Power Distribution
CEC-NRCC-ELC-01-E (Revised 01/16)
CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-ELC-01-E
Electrical Power Distribution (Page 5 of 6)
Project Name: Date Prepared:
Desert Vein &Vascular Institute TI 12/5/2017
C. Voltage Drop Enforcement Agency
Check all boxes below if the electrical power distribution system is in compliance with Section 130.5(c). Check that the system
complies
91 The electrical power distribution system meets the voltage drop requirement of Section 130.5(c). The maximum
combined voltage drop on feeder conductors and branch circuit conductors to the farthest connected load or 0
outlet, do not exceed 5%.
X1 Voltage drop calculation documents showing compliance to Section 130.5(c) are submitted as part of the ❑
compliance document submittal.
D. Circuit Controls for 120-Volt Receptacles and Controlled Receptacles
Field Inspector
Check one or more boxes below for applicable requirements of Section 130.5(d) for the electrical power distribution
Cehck that the system
system.
complies
91 The control is capable of automatically shutting OFF the controlled receptacles when the space is typically
unoccupied, either at the receptacle or circuit level. For the automatic time switch control, it incorporates an
override control that allows the controlled receptacle to remain ON for no more than 2 hours when an override
❑
is initiated and an automatic holiday "shut -OFF" feature that turns OFF all loads for at least 24 hours and then
resumes the normally scheduled operation. Countdown timer switches are not be used to comply with the
automatic time switch control requirements. The controls meet the requirement of Section 130.5(d)1.
❑ There is at least one controlled receptacle within 6 ft from each uncontrolled receptacle. Where receptacles are
installed in modular furniture in open office area, at least one controlled receptacle is installed at each
❑
workstation. The receptacles meet the requirement of Section 130.5(d)2.
❑ There are installed split wired receptacles with at least one controlled and one uncontrolled receptacle. Where
receptacles are installed in modular furniture in open office area, at least one controlled receptacle is installed
❑
at each workstation. The receptacles meet the requirement of Section 130.5(d)2.
91 Permanent and durable marking for controlled receptacles or circuits to differentiate them from uncontrolled
❑
receptacles or circuits is provided. The markings meet the requirement of Section 130.5(d)3.
❑ For hotel and motel guest rooms, there are controlled receptacles for at least one-half of the 120-volt
receptacles in each guest room. Electric circuits serving controlled receptacles in guestrooms are installed to
have captive key controls, occupancy sensing controls, or automatic controls so the power is switched off no
❑
longer than 30 minutes after the guest room has been vacated. The receptacles meet the requirement of
Section 130.5(d)4.
❑ Receptacles that are only for the following purposes are excepted from Section 130.5(d):
-Receptacles specifically for refrigerators and water dispensers in kitchen areas.
-Receptacles located a minimum of six ft above the floor that are specifically for clocks.
-Receptacles for network copiers, fax machines, A/V and data equipment other than personal computers in
copy rooms.
❑
-Receptacles on circuits rated more than 20 amperes.
-Receptacles connected to an uninterruptible power supply (UPS) that are intended to be in continuous use, 24
hours per day/365 days per year, and are marked to differentiate them from other uncontrolled
receptacles or circuits.
CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016
STATE OF CALIFORNIA
Electrical Power Distribution
CEC-NRCC-ELC-01-E (Revised 01/16)
CALIFORNIA ENERGY COMMISSION 4Z
CERTIFICATE OF COMPLIANCE NRCC-ELC-01-E
Electrical Power Distribution (Page 6 of 6)
Project Name: Date Prepared: 1 2/5/201 7
Desert Vein &Vascular Institute TI
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name: Jon d. Scoff
Documentation Author Signature:
Company:
Scott Design and Title 24, Inc,
Signature Date:
12/5/2017
Address: 74818 Velie Way Suite 8
CEA/ HERS Certification Identification (if applicable):
City/State/Zip: Palm Desert, CA 92260
Phone: 760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design
identified on this Certificate of Compliance (responsible designer).
3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system
design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information
provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement
agency fvr approval with this building permit application.
5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the
building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this
Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy.
Responsible Designer Name: Lawrence C. Reeves
Responsible Designer Signature:
Company :
Lawrence C. Reeves, L.P.
Date Signed:
Address: 49-850 Jefferson St., Suite 130
License:
City/State/Zip: Indio, CA 92201
phone: (818) 425-0830
AA
CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Date
Desert Vein & Vascular Institute TI
12/5/2017
System Name
Floor Area
AC 1 -4
3,221
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
4
COIL
CFM
Total Room Loads 6,542
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible I
Latent
CFM
Sensible
Output per System
54,000
117,665
12,153
2,098
31,823
Total Output (Btuh)
216,000
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 483
Supply Fan
Supply Air Ducts
0
Output Btuh/sgft)
67.1
5,883
1,591
Cooling System
0
0
Output per System
53,000
17,591
6,560 483
22,517
Total Output (Btuh)
212,000
0
0
Total Output (Tons)
17.7
5,883
1,591
Total Output (Btuh/s ft)
65.8
TOTAL SYSTEM LOAD
18,713
Total Output s ft/Ton)
182.3
1 147,023
57,522
Air System
CFM per System
1,800
HVAC EQUIPMENT SELECTION
Airflow cfm
7,200
Existing York HVAC
158,852
31,432
134,908
Airflow (cfm/sgft)
2.24
Airflow cfm/Ton
407.5
Outside Air (%)
6.7 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTI=M PEAK
158,852
31,432
Aug 4 PM
134,908
Jan 1 AM
Outside Air (cfmisgft)
0.15
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
(Airstream Temperatures at Time of Heating
Peak)
26 OF
67 OF
Outside Air
483 cfm
Heating Coil Supply Fan
7,200 cfm
ROOM
r
■
70 OF
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling
Peak)
Ill / 78 IF
79 / 65 OF 58 / 57 OF 58 / 57 OF
T-T
Outside Air
483 cfm
Cooling Coil Supply Fan
59 / 58 OF
7,200 cfm
52.3
% ROOM
77 / 64 OF
76 / 64 OF
EnergyPro 7.2 by EnergySoft
User Number: 6712
ID:
Page 29 of 30
ZONE LOAD SUMMARY
Project Name
Desert Vein & Vascular Institute TI
Date
12/5/2017
System Name
AC 1-4
Floor Area
3,221
ZONE LOAD SUMMARY
ZONAL SYSTEM
COOLING PEAK
HEATING PEAK
ZONE NAME
SYSTEM NAME
Mult.
CFM
Sensible
Latent
Heating
OA CFM
Peak Hr
CFM
Sensible
I Latent
CFM
Sensible
Tenant Improvement
1.0
483
Aug 4PM
6,542
135,6511
19,777
2,098
54,447
TOTALS
0
0
0
483
Aug 4 PM
135,651
19,777
54,447
(BLOCK LOAD)
EnergyPro 7.2 by EnergySaft User Number6712 ID: Page 30 of 30