Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BSOL2019-0028 Revision 1
PERMIT # PLAN LOCATION: Project Address: ©( 3 / Project Descriptio3p: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: Applicant Name:[ Address - City, ST, Zip: Telephone: Email: Valuation of Project S C7,-70 Contractor Name: New SFD Construction: Address: �� z C",-X.-eieR- Conditioned Space SF City, St, Zip Garage SF Telephone: 6 U , 4% 9. Z I O Patio/Porch SF Email: Fire Sprinklers SF State Lic: CQZ20City Bus Lic: Arch/Eng Name: Construction Type: Occupancy: Address:. Grading: City, St, Zip Telephone: Bedrooms: Stories: # Units: Email: State Lic: City Bus Lic: Property Owner's Name: New Commercial / Tenant Improvements: Address: Total Building SF City, ST, Zip Construction Type: Occupancy: Telephone: Email: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 SHEETINDEX PV-1 SOLAR LAYOUT PV-2 ATTACHMENT DETAILS PVC ELECTRICAL CALCS PV-3A ELECTRICAL LINE DIAGRAM PVC PLOT PLAN _ NOTES: - Solar Photovoltaic System to be installed on residential structure_ I -Design complying with the latest edition of California Electrical Code, NEC and all local ordinances and policies. -The project has been designed in compliance with the CBC section 1609 to withstand a minimum 110 MPH wind load. - Per sections R314 & R315 within the 2016 California Residential Code (CRC), it's required that smoke alarm and carbon monoxide detectors are retrofitted into the existing dwelling for permits with repairs or additions exceeding $1,000. - Working distances around the existing electrical equipment as well as the new electrical equipment will be maintained in accordance with CEC 110.26 - This system will not be interconnected until approval from the local jurisdiction and the utility is obtained. -This system is a utility interactive system with no storage batteries. -The Solar Photovoltaic installation shall not obstruct any plumbing, mechanical or building roof vents. - When a backfed breaker is the method of utility interconnection, breaker shall not read Line and Load. - All PV equipment shall be listed by a recognized testing lab. - Notify serving utility before PV system activation CODE COMPLIANCE PROJECT DESIGNED BASED ON 2016 CEC ALL SUPPLIED EQUIPMENT IS UL LISTED 2018 CALIFORNIA BUILDING CODE 2018 CALIFORNIA ELECTRIC CODE 2016 CALIFORNIA FIRE DEPARTMENT CODE 2016 CALIFORNIA RESIDENTIAL CODE 2016 ENERGY COMPLIANCE T-24 2014 NATIONAL ELECTRIC CODE GATE J ROOF ACCESS PER CRC R324.6 SOLAR LAYOUT SCALE: 3/32"=1'-O" BACKYARD SYMBOL LEGEND III PETERSENDEAN' ATTIC VENTS u.r Am�a i e C R; 0.,ji MECHANICAL & O 0 1820 CONTAINER CIRCLE JURUPAVALLEY. CA 92509 PLUMBING VENTS P: (951)27 a a CA LIC SE NI(10 D2D1 SOLAR MODULES I 1 II I� PROJECTNAME: FIRE ACCESS L - PATHWAY K CONDUIT MAIN SERVICE PANEL AND UTILITY METER INVERTER (INTEGR. DC DISC.) AC DISCONNECT PV METER JUNCTION BOX J13 GAS METER �G PROPERTY DC) system XISTING Lt.cv Kvv (uLe) system r Z '1& g�a F g V REE CT. A 92253 r M �-'.?� DICTION: QUINTA, CITY OF (16)SILFAB SOLAR INC SLA320M [BILK] (1) SOLAREDGE SESODOH-US (24OV) DRAWING NOTES: 320W MODULE RATED AT: MULTIPLY BY OTY OF MODULES: 16 ARRAY SYSTEM SIZE: _ 5.12 kW SYSTEM AZIMUTH: — 2290 ROOF PITCH: 9'- 202 MOUNTING HEIGHT: 9�TORY ORIENTATION OPTIONS ARE PRELIMINARY, AND ARE SUBJECT TO REVISION FOR OPTIMAL USE. SOLAR ARRAY LOCATIONS ARE TO BE REVIEWED AND APPROVED BY OWNER AND/OR ARCHITECT OF RECORD TO VERIFY SYSTEM LOCATION, FOR VENTILATION OBSTRUCTION AND POSSIBLE RELOCATION OF VENT AND/OR PIPE JACKS. FIELD VERIFICATION OF ROOF STRUCTURE, AND SOLAR ARRAY LOCATION IS REQUIRED PRIOR TO INSTALLATION FOR ALL EXISTING STRUCTURES WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED. _ ARCHITECT/FIELD DRAWING INFORMATION PHZUrMNG .Ne Dermolo I A ovum PV MTE44 JW DUMM19 � PV-1 ^� M;JL © 2018 PETSSOLAR 8 ROOFING INC.. ALL ALL RIGHTS S RESERVED Maximum roof load: 2.63lbsift' Maximum point load: 26.91 Model: Silfab Solar Inc SLA320M [Blk] Weight: 41.8 Lbs Width: 38.97 Inches Length: 64.96 Inches PARTIAL ROOF FRAMING PLAN 1 SCALE:3/32"=1'.0" 1/3`L MAX. TYP. u LU a O U) LL 0 0 4 48" 1 = V1 O C MAX CONT. ALUM. RAIL mr i i ii END MOUNTING L MID. MOUNTING CLIP, TYP. CLIP, TYP. TYPICAL RACK MOUNT LAYOUT SCALE:1/2"=1'-0" 91 O PETERSENDC:Lt; IY it-SER•CA 113t L MAX. 0 _ 1820 CONTAINER CIRCLE TYP. JURUPA VALLEY. CA 92509 ` P; (951) 2769&20 t� r vnr rcaLIG 050201 ;} N PROJECT NAME: 0 0 (r ti3 U O V SEN '5 `` NICE U O C7-J W V 0 OS U REE CT. UIN A, A 92253 N y�,1U1� 0 49.00 I CTION: INTA. CITY OF (16) SILFAB SOLAR INC SLA320M (BLKI (1) SOLAREDGE SE5000H-US (240V) 0 a DRAWING NOTES: MODULE RATED AT: 320W 3/8"-16 X 314 MULTIPLY BY QTY- OF MODULES: 16 —HEX HEAD BOLT 3/8-16 FLANGE NUT ARRAY SYSTEM SIZE: -__ 1 �� w 22 UNIRAC MID CLIP SYSTEM AZIMUTH. - WIT -BOLT & FLANGE N QUICKSCREW 90' SS 9°- 2�12 9 ROOF PITCH: —TILE HOOK W/ 11 a MOUNTING HEIGHT: 1-STORY UNIRAC ALUM. r FLASHING ORIENTATION OPTIONS ARE PRELIMINARY, AND SOLAR PANEL -- SUPPORT RAIL r f*� ARE SUBJECT TO REVISION FOR OPTIMAL USE x CONCRETE S-TILE " SOLAR ARRAY LOCATIONS ARE TO BE x REVIEWED AND APPROVED BY OWNER AND/OR a ARCHITECT OF RECORD TO VERIFY SYSTEM LOCATION, FOR VENTILATION OBSTRUCTION AND POSSIBLE RELOCATION OF VENT AND/OR ` I` a PIPE JACKS. m FIELD VERIFICATION OF ROOF STRUCTURE, AND ? SOLAR ARRAY LOCATION IS REQUIRED PRIOR TO INSTALLATION FOR ALL EXISTING 9" o STRUCTURES WHERE NEW SOLAR ARRAYS ARE 12 _ g5 TO BE INSTALLED- 12 �` N ARCHITECTlFIELO DRAWING INFORMATION 2x4 TRUSS @ 24" OC TYP PERMITTING JW 06IL612018 (2) 5f16" x 4" SS LAG BOLT A DOWNSI2EG PV SYSTEM Jw 0e10d2019 INTO TRUSS(ES) 2 1/2" MIN. o PENETRATION W/ ROOF SEALANT, TYP. - rn CONCRETE S-TILE - QUICKSCREW 90° SS TILE HOOK :J SCALE 1" = 1' PV-2 © 2019 PETERSENDEAN SOLAR & ROOFING INC., ALL RIGHTS RESERVED LABELS NEC 690.5(C) - AT THE INVERTER AND/OR GROUND FAULT INDICATOR LOCATION (AND ALL BATTERY LOCATIONS IF APPLICABLE): WARNING ELECTRICAL SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED NEC 690.13 (B), 690,15(A)(4) - ON AC/DC DISCONNECT: AC PHOTOVOLTAIC DISCONNECT DC PHOTOVOLTAIC DISCONNECT NEC 690.17 - AT JUNCTION BOX, COMBINER BOXES AND AC/DC DISCONNECTS: WARNING ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.35(F) - UNGROUNDED PV SYSTEMS ONLY AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT AND DEVICE WHERE THE UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE: WARNING ELECTRICAL SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED NEC 69056(C) - AT PV SYSTEM DISCONNECT PHOTOVOLTAIC SYSTEM EOUIPPEO WITH RAPID SHUTDOWN NEC 690.53 - ON DC DISCONNECT: PHOTOVOLTAIC SYSTEM DC SYSTEM SPEGFICATIONS OPERATING CURRENT: 13.5 A OPERATING VOLAGE 360 V MAX SYSTEM VOLTAGE: 460 V MAX SYSTEM CURRENT: 30 A NEC 690.52 - ON AC DISCONNECT POINT OF INTERCONNECTION: PHOTOVOLTAIC SYSTEM AC SYSTEM SPECIFICATIONS MAX AC OUTPUT CURRENT: 21 A OPERATING AC VOLTAGE: 240 V OPERATING AC POWER: 4647 W OPERATING AC FREQUENCY: 60 Hz MAXIMUM OCPD RATING: 30 A NEC 705.12(D)(2) - BY BREAKER AT DISTRIBUTION EQUIPMENT: WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE NEC 705.10. 705.12(D)(3)- AT SERVICE EQUIPMENT LOCATION: CAUTION THE ELECTRICAL SYSTEM IS ALSO SERVICED BY A PHOTOVOLTAIC SYSTEM CSFM - DC CONDUIT EVERY 10' INTERIOR/EXTERIOR WARNING: PHOTOVOLTAIC POWER SOURCE PLAQUES SHALL BE PLASTIC ENGRAVED IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP -RIVETS OR ADHESIVE. ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF CALIFORNIA ELECTRICAL CODE WILL BE INSTALLED AS REQUIRED ALTERNATE POWER SOURCE PLACARD SHALL BE METALLIC OR PLASTIC, ENGRAVED OR I MACHINE PRINTED LETTERS IN A CONTRASTING COLOR TO THE PLAQUE THIS PLAQUE WILL BE f ATTACHED BY POP RIVETS OR SCREWS OR OTHER APPROVED METHOD IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT PHOTOVOLTAIC DC CONDUCTORS SHALL BE LABELED, 'CAUTION DC CIRCUIT' OR EQUIVALENT EVERY 5 FT AND KEPT MINIMUM 18' BELOW THE ROOF SURFACE EXPOSED NON -CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENTS, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH 250,134 OR 250135(A) REGARDLESS OF VOLTAGE. EACH MODULE SHALL BE GROUNDED USING THE SUPPLIED CONNECTION POINT IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S INSTRUCTIONS IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. PHOTOVOLTAIC EQUIPMENT SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL ONLY BE INSTALLED BY QUALIFIED PERSONS. ALL CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT EQUIPMENT GROUNDING CONDUCTORS SMALLER THAN 6AWG SHALL BE PROTECTED IN A RACEWAY, PROVIDE SMOKE ALARMS AT THE FOLLOWING LOCATIONS AND NOTE ON THE PLANS; (R314.3 CRC) Max Branch required DC conductor ampacity (2560W)/(380V)(1.25) = 8AA AWG#10, derated ampacity: (40)(0.58)(1) = 23.2A 23.2A > 8.4A, therefore DC wire size is valid. AC required conductor ampacity (21)(1.25) = 26.25A AWG#10, derated ampacity: (40)(0.82)(1) = 32.8A 32-SA > 26.25A, therefore AC wire size is valid- Note: Conduit shall be Installed Min 112" above roofsurface A OUTSIDE EACH SEPERATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDROOMS B. IN EACH ROOM USED FOR SLEEPING PURPOSES. C. IN EACH STORY, INCLUDING BASEMENTS IN SPLIT LEVEL UNITS WITHOUT AN INTERVENING DOOR BETWEEN ADJACENT LEVELS, A SMOKE ALARM INSTALLED ON THE UPPER LEVEL SHALL SUFFICE PROVIDED THAT THE LOWER LEVEL IS LESS THAN ONE FULL STORY BELORE THE UPPER LEVEL. D. ALARMS SHALL BE INTERCONNECTED SUCH THAT THE ACTUATION OF ONE ALARM SHALL ACTIVATE ALL ALARMS. E. ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WITH BATTERY BACKUP- F APPROVED COMBINED SMOKE ALARMS AND CARBON DIOXIDE ALARMS SHALL BE ACCEPTABLE. A CARBON MONOXIDE DETECTOR SHALL BE INSTALLED IN THE SPECIFIC EXISTING DWELLING UNIT THAT HAVE ATTACHED GARAGES OR FUEL -BURNING APPLIANCES FOR WHICH A PERMIT IS ISSUED FOR ALTERATIONS, REPAIRS, OR ADDTIONS EXCEEDING E1,000,00. LISTED SINGLE- OR MULTI -STATION CARBON MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE OF EACH SEPERATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS AND ON EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS. COMBINED SMOKE/CARBON MONOXIDE ALARMS MAY BE USED. THE ALARM SHALL RECEIVE ITS PRIMARY POWER FROM THE BUILDING WIRING EXPECT IT IS PERMITTED TO BE SOLEY BATTERY OPERATED WHERE REPAIRS OR ALTERATIONS DO NOT RESULT IN THE REMOVAL OF WALL AND CEILING FINISHED OR THERE IS NO ACCESS BY MEANS OFF AN ATTIC SHOW ON THE PLANS (R315 CRC) COMPLY WITH CEC SEC. 690.15 (A) 4 AND INSTALL A PLAQUE IN ACCORDANCE WITH SEC. 705.1OAS FOLLOWS: 705.10 DIRECTORY: A PERMANENT PLAQUE OR DIRECTORY, DENOTING AN ELECTRIC POWER SOURCES ON OR IN THE PREMISES, SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT LOCATION AND AT LOCATIONS OF ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OR BEING INTERCONNECTED. PHOTO -VOLTAIC PANEL THERE ARE NOT INTEGRAL PART OF THE ROOF COVERING SYSTEM SHALL BE INSTALLED WITH A MINIMUM THREE (3) INCH CLEARANCE FROM THE SURFACE TO THE PANEL COMPLY WITH CEC ARTICLE 250. 56 FOR EXISTING RESISTANCE OF ROD, PIPE, AND PLATE ELECTRODES. A SINGLE ELECTRODE CONSISTING OF A ROD, PIPE, OR PLATE THAT DOES NOT HAVE A RESISTANCE TO GROUND OF 25 OHMS OR LESS SHALL BE AUGMENTED BY ONE ADDITIONAL ELECTRODE OF ANY OF THE TYPES SPECIFIED BY 250-52(Ax4) THROUGH (Ax8). WHERE MULTIPLE ROD, PIPE. OR PLATE ELECTRODES ARE INSTALLED TO MEET THE REQUIREMENTS OF THIS SECTION, THEY SHALL NOT BE LESS THAN 1.8 M {6 FT)APART. SHALL PROVIDE AN AUXILIARY GROUNDROF IT IT CANNOT BE PROVEN THAT THE EMSTiNG GROUNDING HAS HAVE A RESISTANCE TO GROUND OF 25 OHMS OR LESS. Silfab Solar IncSLA320M Blk UL1703 Power 320 W 40.45 Var, 33.7 Vmp, 20 Vnom 9.96 Isc, 9.5 Imp 600 V, UL E42728, NEMA 3,4,4x,6,12,13 SOIarFd a SE5000H-US (240Vi UL 1741, NEMA 3R, IEEE 1547 No6 Output Voltage 240V' Mai Out ut Current 21 AI No. fModules - Branch 1 8; No. fModules - Branch 2 8 No- f Modules - Branc h c 0 LhAber Modules 16i Record low temp 137 �_+:Y���-�I€3i'If���Xtslyr:� �t=tt7��f-'i..•v Max AC Output Cunent 21 Al Operating AC Voltage _ 240VI Operating AC Power 4647 W' Operating AC Frequency 60 Hz Max OCPD Rafin2 30 A SolarEdge P320 Max Output Voltage 60VDC, [max 15A UL1741, EC62109-1, NEMA 6P SID D DU221RB UL E2875, NEMA 3R 30 A, 240 V, NON -FUSIBLE i A EX PV EQUIPMENT i XANTREX ,M.3N-NA-240/2138 UL 1741, NEMA 3R, IEEE 1547 INom Output Voltage 240 V ,Max Out ut Current 13.8 A EATON DG222URB UL E5239, NEMA 3R 60 A, 240 V, NON -FUSIBLE PETERSER- Fr,:,! 182000NTAINER CLE JURUPA VALL , CA 92509 P:(951)27611a 90 WWW.Pe!e endean,Com C6&PC6NE No1050201 PROJECT NAME: VI ELI AD HANSEN n RESIDENCE w 81392 JOSHUA TREE CT. LA QU I NTA, CA 92253 JOB # 46949.00 JURISDICTION: L� LA QUINTA, CITY OF 3 (16) SILFAB SOLAR INC SLA320M [BLKI (1) SOLAREDGE SE5000H-US (240V) DRAWING NOTES: MODULE RATED AT: 320W --� MULTIPLY BY QTY. OF MODULES: 16 ARRAY SYSTEM SIZE: 5.12 kW g SYSTEM AZIMUTH: 2290 :n ROOF PITCH: 9'- 2/12 Om MOUNTING HEIGHT: 1—STORY - IORIENTATION OPTIONS ARE PRELIMINARY, AND m ARE SUBJECT TO REVISION FOR OPTIMAL USE, SOLAR ARRAY LOCATIONS ARE TO BE REVIEWED AND APPROVED BY OWNER AND/OR ARCHITECT OF RECORD TO VERIFY SYSTEM LOCATION, FOR VENTILATION OBSTRUCTION AND POSSIBLE RELOCATION OF VENT AND/OR PIPE JACKS. FIELD VERIFICATION OF ROOF STRUCTURE, AND SOLAR ARRAY LOCATION IS REQUIRED PRIOR TO INSTALLATION FOR ALL EXISTING STRUCTURES WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED. ARCHITECT/FIELD DRAWING INFORMATION PERA+ITFNG JVJ W262019 CURRENTCARRYINC CONDUCTOR CAlC UPDATE JW OB252019 PV-3 © 2018 PETERSENDEAN SOLAR 8. ROOFING INC., ALL RIGHTS RESERVED PHOTOVOLTAIC ARRAY BRANCH CIRCUIT 1 = 8 MODULES DC -DC POWER INVERTER (240V) OPTIMZER 4-71 & INTEGRATED JUNCTION DC DISCONNECT BOX W/ INTERNAL GFDI & 1 BRANCH CIRCUIT 2 = 8 MODULES EGC AWG #10 I THWN-2 IN PV WIRE IN FREE AIR 3/4" EMT POS = RED AWG #10 NEG = BLACK POS = RED AWG #6 NEG = BLACK G = BARE CU AWG #8 G = GREEN PHOTOVOLTAIC ARRAY BRANCH CIRCUIT 1 = 31 MODULES DC -DC POWER OPTIMZER PV METER (240V) 0 EXISTING PHOTOVOLTAIC ARRAY TO BE REPLACED PV BREAKER 30 A DPB SQUARE D HOM230 OR COMPATIBLE BREAKER LOCATED FARTHEST FROM MSD 30 A RATED AC DISCONNECT (240V) Ll I THWN-2 IN 3/4" T ^ L1 = BLACK L2 =RED N = WHITE AWG #8 G = GREEN JUNCTION 60 A RATED BOX INVERTER (240V) AC DISCONNECT PV METER (240V) (240V) I �y o I (E) CONDUCTORS (E)CONDUCTORS ~ ~ EXISTING 225 A RATED SQUARE D MAIN SERVICE PANEL 200 A ~ MAIN DISCONNECT BI-DIRECTIONAL UTILITY METER o rI 1 1 PHASE, 3 WIRE 120/240 V b r c a NEW, IF NO 0 EXISTING u GRGUNDING ELECTRODE 2 " u E 2 u i' 0 TO A 20A I 10 DPB @ MSP a s a a El PETERSENDEAN #1 Home ",xocmrnl CM1�Mv AMERICA AMERICA APWa 1820 CONTAINER CIRCLE JURUPA VALLEY, CA 92509 P:(951)27 www ndean.¢om C IC S No1050201 36 -20 PROJECT NAME: HANSEN RESIDENCE 81392 JOSHUA TREE CT. LA QUINTA, CA 92253 JOB # 46949.00 JURISDICTION: LA QUINTA, CITY OF (16) SILFAB SOLAR INC SLA320M [BLK] (1) SOLAREDGE SE5000H-US (240V) DRAWING NOTES: 320 V V�p� MODULE RATED AT: 16 MULTIPLY BY QTY OF MODULES: 5.12 kW ARRAY SYSTEM SIZE: 2290 SYSTEM AZIMUTH: 90_ 2/1 2 ROOF PITCH: 1 -STORY MOUNTING HEIGHT: ORIENTATION OPTIONS ARE PRELIMINARY, AND ARE SUBJECT TO REVISION FOR OPTIMAL USE SOLAR ARRAY LOCATIONS ARE TO BE REVIEWED AND APPROVED BY OWNER AND/OR ARCHITECT OF RECORD TO VERIFY SYSTEM LOCATION, FOR VENTILATION OBSTRUCTION AND POSSIBLE RELOCATION OF VENT AND/OR PIPE JACKS FIELD VERIFICATION OF ROOF STRUCTURE, AND SOLAR ARRAY LOCATION IS REQUIRED PRIOR TO INSTALLATION FOR ALL EXISTING STRUCTURES WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED ARCHITECT/FIELD DRAWING INFORMATION PERMITTING JW O6I26I2019 A CURRENT CARRYING COHMCTOR CAI'C IIPOATE JW 08/2512019 B REWNE9 CORRECTIONS JW i19H812019 C ADO AC INSCO14KECT OT 10I9/2019 PV-3A © 2018 PETERSENDEAN SOLAR & ROOFING INC, ALL RIGHTS RESERVED I I ao SOLAR PV ON ROOF INVERTER— I MAIN PANEL & METER & MAIN SERVICE DISCONNECT PV METER AC DISCONNECT 51/-11 0 1 r � SWIMMING POOL BACKYARD i\ DRIVEWAY ,x1 PLOT PLAN 1 ' SCALE: 1"=20' J j0. 0 PETERSENDEAN Hdrctiyryyo44xyy 1CmtrA- ��CC41 xrM. ICA AMEAICJ� AN 1820 CONTAINER CIRCLE JURUPA VALLEY, CA 92509 276.4tor dean.com No 1050201 a 8, - 0 PROJECT NAME: HANSEN RESIDENCE 81392 JOSHUA TREE CT. LA QUINTA, CA 92253 JOB # 46949.00 JURISDICTION: LA QUINTA, CITY OF (16) SILFAB SOLAR INC SLA320M [BLKI (1) SOLAREDGE SE5000H-US (240V) DRAWING NOTES: 32 0 W MODULE RATED AT: 16 MULTIPLY BY OTY OF MODULES: 5.1 2 kW ARRAY SYSTEM SIZE: 2290 SYSTEM AZIMUTH: 90= 2/12 ROOF PITCH: 1-STORY MOUNTING HEIGHT: ORIENTATION OPTIONS ARE PRELIMINARY, AND ARE SUBJECT TO REVISION FOR OPTIMAL USE. SOLAR ARRAY LOCATIONS ARE TO BE REVIEWED AND APPROVED BY OWNER AND/OR ARCHITECT OF RECORD TO VERIFY SYSTEM LOCATION, FOR VENTILATION OBSTRUCTION AND POSSIBLE RELOCATION OF VENT AND/OR PIPE JACKS. FIELD VERIFICATION OF ROOF STRUCTURE, AND SOLAR ARRAY LOCATION IS REQUIRED PRIOR TO INSTALLATION FOR ALL EXISTING STRUCTURES WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED. ARCHITECT/FIELD DRAWING INFORMATION PERMITTING m 06AW19 A CURRENT CARRYING CONDUCTOR CALC UPDATE '� OB25I2019 9 REDLINES CDRRECTIGN$ iw 091192019 C ADDAr OISCONNECT DT 10f9R019 PV-4 © 2018 PETERSENDEAN SOLAR & ROOFING INC., ALL RIGHTS RESERVED CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: U BACKYARD SOLAR PV ON ROOF INVERTER MAIN PANEL & METER & MAIN SERVICE DISCONNECT PV METER AC DISCONNECT El PETERSENDEAN ��,.��.Al Fb—Ynp aremam (mVr d' .1i ,;,a AMERICA. AMERKA 1620 CONTAINER CIRCLE JURUPA VALLEY, CA 92509 P: (951) 276-4890 Vmw P.t—."d660 — CA LICENSE No 1050201 C-46, C38, C-20 HANSEN RESIDENCE 81392 JOSHUA TREE CT. LA QUINTA, CA 92253 JOB # 46949.00 JURISDICTION: LA QUINTA, CITY OF (16) SILFAB SOLAR INC SLA320M IBLN (1) SOLAREDGE SE5000H-US (240V) MAP PLACARD 2616 PETERSEN DEAN ROOFING& SOLAR SyDTIAM, W- ALL kMM RESERVED Product data sheet Characteristics DU221 RB SWITCH NOT FUSIBLE GD 240V 30A 2P NEMA3R Product availability : Stock - Normally stocked in distribution facility Price*: 177.00 USD Main O g Product or component type Single Throw Safety Switch $ n Line Rated Current 30 A Product certifications UL listed o a NEMA degree of protection NEMA 3R Disconnector device type Non -fusible disconnect 0 Device composition None a Device mounting m Surface N Number of poles 2 Electrical connection Lugs d Series name General duty g Ordering and shipping, details m a s Category 00106 - D & DU SW,NEMA3R, 30-200A Discount Schedule DE1A R GTIN 00785901490340 Nbr. of units in pkg. 1 Package weight(Lbs) 4.8600000000000003 Returnability Y Country of origin MX Contractual warranty Warranty period 18 months N L F Lne le Lei $er - - - . - Without Bypass 100 Amp Self -Contained • Single meter position "��! • Designed to receive watthour meters that meet ANSI C12.10 • Surface or semi -flush mounting Qn—� • Overhead or underground feed • Type 3R construction :� • Snap type sealing ring included • 5th jaw provision at nine o'clock — 011 series only • Ring style 11 • UL 414 listed, complies with ANSI C12.7 • ANSI 61 gray acrylic electrocoat finish • 5th jaw kit — catalog #50365 • • Screw type sealing ring — catalog #25016D (included with MS73 catalog numbers) • Steel and clear lexan covers for socket opening • AW hubs CONI]ULTTTT7 Luc RANGE DIMENSIONS (INCNES) CATALOG Q1C QIAPl1GHY $ER.%,j NUMBER HUB PHASE CONDUCTOR NEUTRAL FIGURE HEIGHT WIOIH DEPiN N4IMREN RATING MAX CONT VDkTAGT !!! Frra OF JAWS PROV.' LINEILDAD COrJDDCTGR f NUMBER (H) 1 (i'Ul (Dl .11 a®iiiiiia■����®�® • • CONDUCTOR LUG RANGE DIMENSIONS (INGIES) L'ALIk !�QIC Q4APACITY l 5i R': F:.f NurADCR HUD PHASE CDNDDGIDR NEUTRAL FIGURE HEIGHT WIDTH D:I'TH . NUIIBIT' RATING M, CONT VULIAGL Ivc OF JAVVS PR DV LINEILDAD CONDUGTDR Nu%IBLR (H) f (ty) (D) Underground -Surface Mount - 1 1 1• 1 1 CATALOG QIC QMPACITY SERVILE NUNUR Hua I PHASE CUNDUCTOR I NEUTRAL FIGURE I HEIGHT INPI)THi I DFPTH NUMBER RATING MAX CONT VOLTAGE I 1Vff OF JWY Nriv LINEILDAD CONDUCTOR NUMBER (H) jVIVj (D) t = Meter sockets shown on this page have certain short circuit current ratings when used In conformance with the tables on page B. 2COOZ B-Line Data subject to change without notice. Consult local utility for area acceptance. All dimensions in inches.