001178 (SFD) Compaction ReportBuenO EnnineusAnc.
f
RECEIVED
FF 01
COMMUC:TY OF LA ppUINTA
NITY OEVELOUINTADEPT
1731-A WALTER STREET VENTURA, CALIFORNIA 93003 PHONE (805) 642-6727
January 251, 1985 Job No..B-14989-P1
85-1-223
Pomona Valley -Equipment
P.O. Box 457
La Quinte, CA 92253,
Subject: 53-300,.53-320, 53-340 Ave. Ramirez
La Quinta, CA -.
r Compaction Report
Gentlemen:.
On January 21,1985 a representative of our firm performed den'
sity tests on the fill placed -in the building_area on the above re-
ferenced project. Tests were performed at random loc�'t"ions i'ri ac-
cordance with ASTM 2922-78 and ASTM 3017-78 Nuclear Density Test
Procedure. Tests performed as. per.,authorization of Bob Mc Callum.
i
The "estimated locations of the tests are'presented'on the attach -
a ed plan with'their results being summarized on the attached test re-
port sheet. 'A total of six (6) density -tests were performed.
j Test results indicate thata minimum -of ninty.percent (90%) of rela
l tive compaction has been obtained within the areas tested. -'The
"j maximum density -optimum moisture was determined in the laboratory in
§ accordance with ASTM D 1557 -78, -Method A, five (5)" 'laver curve.
Classification Maximum Density -Optimum Moisture
Light brown silty fine sand 108..9 14.2
y
VENTURA
LANCASTER
(805) 642.6727
{805) 948.7538
THOUSAND OAKS BAKERSFIELD
SANTA BARBARA PALM SPRINGS SAN LUIS OBISPO
(805) 495.8484 (805) 327.5150
(805) 966.9912 (714) 328.91:31 (805) 544.6187
IV
January 25, 1985 Job -No: E• -14.989-P1
65-1-223"",
LIMITATIONS
The backfilling and.compacting operations were. completed. at -the
time our personnel were called to
'the site.- The test results summa
rized in..this,report'represent the moisture and density only at -the
location and, depth tested on the -specified --date. The:summarized.field
and•laboratory tests were.performed in accordance withe'ngineering
principles'generally, accepted at -this. time and location, No opinion
is expressed as to. the uniformity. of the material, compaction nor the
adequacy of the material .to perform its intended function. N6.quar
antee or warranty of the contractors work is made or. implied.
Respectfully submitted,
BUENA ENGINEERS,' IN.C. -Reviewed and Approved .
Norman G.,Jac son, J Raymo d E..Brannen
NGJ/REB/kIs C.E:. `28966 _
Copies:
4- Bob McCallum
27 City of La Quinta
1- P.S. file
1- Vta. file
a
v
•�
y
cr-
Z
W
W
h
iL
uj
H
p
=
1
m
•
r
y
��y �luo-7 1 a�