Loading...
BMCH2019-041578-495 CALLE TAMPICO T4tit D 4-v Quih& VOICE (760) 777-7125 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 10/3/2019 Permit Type/Subtype: MECHANICAL/ Owner: Application Number: BMCH2O19-0415 DARNELL K. & VICTORIA L. DORSEY Property Address: 81075 MONARCHOS CIR CIR 81075 MONARCHOS APN: 767780045 LA QUINTA, CA 92253 Application Description: DORSEY / HVAC CHANGE OUT - 14SEER/80AFUE MINI -SPLIT SYSTEM Property Zoning: Application Valuation: $4,600.00 Applicant: Contractor: IE INC D ESSER SERVICES INC DBA ESSER AIR CONDITI 31225 LA BAYA OCT 0 3 2019 P 0 BOX 1636 WESTLAKE VILLAGE, CA 91362 CATHEDRAL CITY, CA 92235 CITY OF LA QUINTA 550 DESIGN& DEVELOPMENT DEPARTMENT LIc. (760)32)324-04-0 50 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C20 License No.: 4 Date: i'� 'r `'� Contractor,.__? l _A_� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or countythat requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Da Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: WORKER'S COMPENSATION DECLARATION hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' ompensation, as provided for by Section 3700 of the Labor Code, for the performance F the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by ection 3700 of the Labor Code, for the performance of the work for which this permit is osued. My workers' compensation insurance carrier and policy number are: arrier: INSURANCE COMPANY OF THE WEST— Policy Number: WSD503016704 _ I certify that in the performance of the work for which this permit is issued, I hall not employ any person in any manner so as to become subject to the workers' ompensation laws of California, and agree that, if I should become subject to the corkers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith omply with those provisions. late: A- 75 j I c= Applicant: - YARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, ND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO iNE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF OMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, 4TEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT WPORTANT: Application is hereby made to the Building Official for a permit subject to ie conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose =quest and for whose benefit work is performed under or pursuant to any permit issued s a result of this application , the owner, and the applicant, each agrees to, and shall efend, indemnify and hold harmless the City of La Quinta, its officers, agents, and mployees for any act or omission related to the work being performed under or allowing issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not ommenced within 180 days from date of issuance of such permit, or cessation of work )r 180 days will subject permit to cancellation. certify that I have read this application and state that the above information is correct. agree to comply with all city and county ordinances and state laws relating to building Instruction, and hereby authorize representatives of this city to enter upon the above- ientioned property for inspection purposes. ate: �—Signature (Applicant orAgent),—�•+�.s � Date: 10/3/2019 Application Number: BMCH2O19-0415 Property Address: 81075 MONARCHOS CIR CIR APN: 767780045 Application Description: DORSEY / HVAC CHANGE OUT - 14SEER/80AFUE MINI -SPLIT SYSTEM Property Zoning: Application Valuation: $4,600.00 Applicant: IE INC 31225 LA BAYA WESTLAKE VILLAGE, CA 91362 Owner: DARNELL K. & VICTORIA L. DORSEY 81075 MONARCHOS LA QUINTA, CA 92253 Contractor: ESSER SERVICES INC DBA ESSER AIR CONDITI P O BOX 1636 CATHEDRAL CITY, CA 92235 (760)324-0550 Llc. No.:489046 Detail: REPLACEMENT OF 2 - TON HVAC DUCTLESS MINI -SPLIT SYSTEM CHANGE OUT - 14SEER/80AFUE SPLIT SYSTEM. CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. 2016 CALIFORNIA BUILDING CODES. DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT CITY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM 101-0000-42402 0 $40.25 DESCRIPTION ACCOUNT CITY AMOUNT HVAC CHANGEOUT - SPLIT -SYSTEM PC 101-0000-42600 0 $80.50 Total Paid for MECHANICAL CHANGEOUT 2019: $120.75 DESCRIPTION ACCOUNT CITY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $101.97 Total Paid for PERMIT ISSUANCE: $101.97 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 00771 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT CITY AMOUNT I TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 Zia Qai4ra PERMIT # `✓ �' l — Oy1S PLAN LOCATION: Project Address: 2 l C» S CJ Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN#: Applicant ��Ve+vc'_�r1 fir' �-, . _re•' Address: ', �"� � C� � rz, I `T City, ST, Zip:31U Z Telephone: Email: Valuation of Project $ Contractor Name: r New SFD Construction: Address: IJrj �x Conditioned Space SF City, St, Zip �'���� �Y� I J Cry C 7 2 , Garage SF Telephone: 7( _32') _ �, J C- Patio/Porch SF Email: Fire Sprinklers SF State Lic: City Bus Lie: Arch/Eng Name: Construction Type: Occupancy: Address: Grading: City, St, Zip Telephone: Bedrooms: Stories: # Units: Email: State Lie: City Bus Lie: Property Owner's Name: �i New Commercial / Tenant Improvements: Address: L,� Total Building SF City, ST, Zip L ,� �� �- Construction Type: Occupancy: Telephone: Email: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 OFFICE USE ONLY # Submittal Req'd Rec'd Plan Sets Structural Calcs Truss Calcs Title 24 Calcs Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License CERTIFICATE OF COMPLIANCE Alterations to Space Conditioning Systems (formerly CF-1R-ALT-1HVAC) Project Name: Keith Dorsey I Date Prepared: CF1R-ALT-02-E (Page 1 of 3) 2019-10-03 A. General Information CF111-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF111-ALT-02 document for each dwelling unit. 01 Project Name Keith Dorsey 02 Date Prepared 2019-10-03 03 Project Location 81075 Monarchos Circle 04 Building Type Single family 05 CA City La Quinta 06 Dwelling Unit Name Keith Dorsey 07 Zip Code 92253 08 Dwelling Unit Conditioned 4054 Floor Area (ftZ) Number of Space 09 Climate Zone 15 10 Conditioning (SC) Systems in 1 this Dwelling Unit: B. Space Conditioning (SC) System Information 01 02 03 04 05 06 07 08 09 10 Is the SC Installing a SC System SC System CFA served system a refrigerant Installing new SC Installing Installing Installing Identification or Location or Area by this SC ducted containing system more than 40 entirely new entirely new Name Served System (ftZ) system? component? components? feet of ducts? duct system? SC system? Alteration Type Entirely new or System 1 Location 1 4054 No No Yes No No Yes complete replacement space conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)1Diib) This section does not apply to this project. Registration Number: 419-A020108441A-000-000-0000000-0000 Registration Date/Time: 2019-10-03 07:49:45 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-10-03 07:49:44 Schema Version: rev 20180426 CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC) (Page 2 of 3) D. Altered Space Conditioning System (Sections 150.2(b)1E and F) This section does not apply to this project. E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)iDiia and 150.2(b)1E, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C) 01 02 03 04 05 06 07 08 09 10 it Heating Cooling System Heating Minimum Cooling Minimum Required Identification or Heating System Altered Heating Efficiency Efficiency Cooling Altered Cooling Efficiency Efficiency Thermostat New Duct Name Type Component Type Value System Type Component Type Value Type R-Value Heating This field Ductless All new heating Seasonal Ductless All new cooling SetbackTher or section System 1 mini -split HP components Performanc 8 mini -split HP components SEER 14 mostat is not a Factor applicable (HSPF) Required Documentation: CF2R-MCH-01-E - Space Conditioning Systems - Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16) CF2R and CF3R-MCH-20-H Duct Leakage Test required - Leakage rate compliance: <= 5%. CF2R and CF3R-MCH-22 Fan Efficacy CF2R and CF3R-MCH-23 Airflow Rate Verification Compliance: Fan Efficacy <= 0.58 W per cfm and System Airflow >= 350 cfm per ton. Alternative Compliance: CF2R and CF3R-MCH-28 Return Duct Design verification is an alternative to MCH-22 and MCH-23 verification. CF2R and CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). Exceptions: Heating -only systems are exempt from the 0.58 W per cfm and 350 cfm per ton requirements. Note: An "entirely new or replacement duct system" means at least 75% of the duct system is new duct material, and up to 25% may consist of reused parts from the dwelling unit's existing duct system (e.g., registers, grilles, boots, air handler, coil, plenums, duct material) if the reused parts are accessible and can be sealed to prevent leakage Registration Number: 419-A020108441A-000-000-0000000-0000 Registration Date/Time: 2019-10-03 07:49:45 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-10-03 07:49:44 Schema Version: rev 20180426 CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC) (Page 3 of 3) Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Cassidy Snow C lrwv Company: Signature Date: I Permit E Raters 2019-10-03 Address: CEA/ HERS Certification Identification (if applicable): 31225 La Baya Drive City/State/Zip: Phone: Westlake Village CA 91362 818-735-7876 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Responsible Designer Signature: Shantel Faugno S heel/ Company: Date Signed: Esser Services, Inc. 2019-10-03 Address: License: PO Box 1636 489046 City/State/Zip: Phone: Cathedral City CA 92235 760-324-0550 Digitally signed by CHEERSTM. This digital signature is provided in order to secure the content of this registered document; and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 419-A020108441A-000-000-0000000-0000 Registration Date/Time: 2019-10-03 07:49:45 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-10-03 07:49:44 Schema Version: rev 20180426 Esser Services Inc. PO Box 1636 Cathedral City, CA 92235 License # 499046 unotner IritormRtiolt Date i OBl13rt9 Name Kean Dorsey Address 51075 Monarchos Clfde i T�' Permit Install ❑Divot a or •.u} y/F.1119 i an l � En Phone Home Improvement contract Phone p3DI605-5251 OILY La Ouirda, CA State CA 21p 82253 set ONO-Vent.tnc'ft ra Clteifln Saver-Watet Switch ❑ Electrical Pi II s 135v" ❑FAU street metal Platl0fm ❑ Furnace Flu Vent ®S stem Staftu rlrac Alex & serviceValve" HRefri erantthar e �--- ®AemaveOld E All tnent ❑ Electrical Whi s)-230v"" ❑BackupDrainPan ®HeaVCWo (stern Test tdlab Jte Clean-u C�Condenser Pad(,)" ❑New Suppl Plenum"' PJJobsite Inspection ❑CO2 detector ONew Line Set proper size) ❑ New Return Plenum"` ❑ supply Duct Runs ❑Seal callingcans' El Line Set Cover" ❑5tandard Air Filter ❑ Return Duct Runs ` ❑ Insulate retuttt Plenum• RIThermostat""" (see sco e) ❑ Bar Type Su i Re ister s ❑ New Condensation Pump ❑ FAU Filter Base' El New Low Voltage Wire" ❑ Bar a Relurnf;rille'sl ❑ Ali ■sttorerv&.vr tHlsc de ` Seeaderd Walrrarttia isRo Condenser FUJiTSU Coolln 5 s. VS Com ressor Warranty 2 'feat TParts Model g AOU24` Heatin 5 . VS Warren 12 Year Outdoor J PCKG Unit Ultra -Quiet YES coil wrrardy 02 Year NO Labor Warrar 1 jYear Model # _ Communicating _ FAU FUJITSU lNor"iv-Details FAU Madelir ASU12/ASU15 Vxrlablespeed Indoor YES Gas Electric NO pFUI: Variable SpeedOutdoor YES Heat Pump YES Indoor Braid Weather Proof Top YES position _ ThermostatU e Typer HONEY WELL WtFl YES $ 800.00 Energy r Efficiency Air Quality IME2 Electronic $ & Electrical Protection TY.Fe $ Equipment Extended tabor Warranty Len th _ EISYr. ❑ 10 Yr. ❑ t2 Yr. $ _ Protectfon Other Describe 5 of.viwk herol do.,scriptlitwitalthe-work robe d D ii00.ti0 ESSER SERVICES INC; TO INSTALL FUJITSU MINI SPLIT 24,000 BTU TWO ZONE SYSTEM, OUTDOOR UNITY WILL MOUNT ON PAD LOCATED ON THE GARAGE SIDE. ATTACH POWER, ADD TITAN COVER ON WALL, RUN LINE SETS THROUGH WALL, LINESET WILL RUN UP INNER WALL. WALL MOUNT 15,000BTU FOR CAR SIDEONE FOR PARKING AND 50' LINESET RUNS U ITO ATTIC SPACE TO GALF CART GARAGE FOR 12,000 BTU WALL MOUNT. ADD HONEYWELL WIFI HARD WIRED THERMOSTATS, ASIST CUSTOMER WITH PROGRAMING THEFW.OSTAT AND SETING UP A Allefoximate Start Date 08/20/19 A ] roxlmaie tbrn fetion Clate 1 00120/19 Billing: slifl DeteRf $6000,00 _ Equipment Price Method ❑CC ❑ Csh ❑ Chk ❑ Othr $ewoo Total Options YGrene 05 Yr, Q 10 Yr. ❑ 15 Yr. $ 200.00 Manufacturer Instant Rebates / Esser Instant Rebates HERO 05 Yr. ❑ 10 Yr. ❑ 15 Yr. 5640.00 Down Payment 10 percent or $1,000, whichever is less) Financing % APR for Months $ 5760.00 Total Amount Due Upon C*mp letie n indudes Tax check# tast4 cC Customer Signature Customer Print 1I IV Dater1119 f Approval Esser Re MATHEWGAWN Date 06/13/19 ioZ t witial)"The law requires that the contractor give you a notice explaining your right to cancel. IntTV1ritial the heck x if the contractor has given you a 'Notice of the Three. Day Right to Cancel."' ifna.pffet - �-----.. - — j ! "Items may not be appficabie due to the configuration of the epplfeatlon. If rnocifficstion is not possible, the checked or unchecked boxes may not apply, '*items are being connected to e)dsting materials. Esser AC shall not be held responsible for Items that maybe defected outside of the scope of work '•Utility rebates are not Included in this transaction and Esser holds no liability for Issues between the customer and utility companies Unless otherwise specified, this proposal does not include modifications to ducting, line sets, roof, high and low voltage, or condensation drains • Exrended warranties are backed by 19 & Associates. No transfer fees or deductibles. Choice of licensed HVAC contractor Is customer choice. • Customer will carry necessary insurance on the home prior to work (fire, etc.) Warranty work and regular labor is performed during regular business hours M-F 7:30-SPM unless otherwise specified in above agreement, Warranty work can be performed after hours if customer decides to pay the difference between regular and after hours' time. • Esser reserves the right to cancel this contract prior to the swrt of the project at any time for any reason, • Esser is not responsible for any loss or damage to equipment or other materla is once It is placed on jobslte, Roof screening is not included • Changes and/or necessary modifications that are discovered during the time of installation will required written consent from both parties, • A service charge of 4-5%per rrxmth will be added to all Invoices not paid within 10 days of completion date. ANOTICE CONCERNING WORKERS' COMPENSATION INSURANCE 15 ATTACKED TO THISCOMRACT #.2 dis ute resolved betvueen pwneS att� tgp�d[tOt ARBiTRf►TtOH aF t715PtSSES AHt] tN-HQ1f5ti: flISP�� ntt are aareeing initialing in the spare beloul y gy fnitiall mg below (Arbiti0tian of Disputes area You are agreeing la have al>Y caulornia law and You are giving uP anY t,ib be permitted over the mternet andwVll Np!A h[tration asopr6 Vded by that no reviews u may he to have lng up you P any dispute arising out of the matters included In the '' t0 this provision,+fo fights you might passers to have the dispute 1160ted in a court Atr�aicluded init1+e alter agreeing6oithis agr eme tip this d and appeal. unless those rights are specificallylions code or other applirabie laws. iudwas rights to discovery ree to submit disptlteS atising out of the matters tampetled to arbitrate under the authotSty of tl* business and pro and ag ovtston tsvalun ry. -we have read and understand the tosegoiitp arbitration ps t ores" 4tmAslan to t>eutral attilttalion irxlrrdcdintt�e"pshlttati o Date: �r✓ Customer initials COMMERCIAL GENERAL LIABILITY INSURANCE a YOU may call This contractor carries commercial general l at i6-46 9363 insurance written the Castl point Na r's nuurarnce overagel Insurance Comp ny. CastlePoint National Insurance Company WORKERS' COMPENSATION INSURANCE This contractor carries workers compensation insurance for all its employees. MECHANICS LIEN WARNING Anyone who helps improve your property, butwho is not paid, mayrecord what Is called a mechanics' lien on your property A mechanics' Hen isa claim, like a mortgage or home equity loan, made against your property 1peretarded with the propel retarder. Even if you pay Yauf contractor in fu11, unpaid subcontractors, suppliers, and laborers who helped to Improve Your prapeTLY mtxaiice or record meOlanics liens and sue You in court to foreclose the Ilen. If a court finds the lien is valid, you could be forced to pay i,ave a enurt officer soil your tinme to pay the lien. Liens can also affect your rredlt. To preserve their rigl+t to record a lien, ea ch subcontr acto r and mater lal Suppllec muet provide you with rincuecalled day prellminai y Notice.' This notice is not a Hen. The purpose of the notice is to let you know that the person who send s sends you the notice oti has the right to record a lien on your proper ty If he or she is not paid. ovides 0E CARE FUL. The Preilminaiy Notice can be sent up to 20 daysu�y¢ile subbed the proellmmery Notices you 1 starts work a( tile wilisnatrget Prel malnary lids can be a big problem it you pay your contractor betas you know they are Notices hom your prime contractor or from labarerswho work on your project. The law assumes that you already improvingyour property, ttln a list from your ennirartorof all the suhcanlractors pROTE Cr YOURSELF FROM LiENS. You can protect yaursalf from liars by ge $ and material suppliers that work an your project. Find out from yorlr cont ractor when thew. subcontractors started work and when these suppliers delivered grids or materials. Then wait 2ti days pth a join the k.rwhen o i lie pyour font actor tells yourallmi naty Notices You it ss ttllme to pay for PAY W ITH 101NT CHECKS. One way to protect yourself is to pay j ttre work of a sub con trartot or supplier who has provided you with a Preliminary Notice, write a lointrheckpayable to hoththe contractor and the subcontractor or material supplier. For other ways to prevent liens, visit [SIB'S website at www.csib.ca.gov or call C5L8 at 1.800.321-CSLB (2752)• Remember, if you do nothing, you risk having a lien placed on your home. This can mean ll:at you may have to pay twice, or face the forced sale of your home to pay what you owe. INFORMATION ABOUT THE CONTRACTORS STATE LICENSE BOARD (CSLB) CSLB is the state consumer protection agency that licenses and regulates construction contractors. Contact CSLB for information about the licensed contractor you are considering, including information about disclosable complaints, disciplinary actions and civil judgments that are reported to CSLB. Use only licensed contractors. If you fi le a complaint against a licensed contractor within the legal deadline (usually four years), CSLB has authority to investigate the complaint. if you use an unlicensed contractor, C5LB may not be able to help you resolve your complaint. Your only remedy may be in civil court, and you may be liable for damages arising out of any injuries to the unlicensed contractor or the unlicensed contractor's employees. For more information: VISIT CSLB's website CALL CSLB at 1-800-321-CSLB (2752) WRITE CSLB at P.O. Box 26000, Sacramento, CA 95826 THREE-DAY RIGHT TO CANCEL You, the buyer, have the right to cancel this contract within three business days. You may cancel by e-mailing, mailing, faxing, or delivering a written notice to the contractor at the contractor's place of business by midnight of the third business day after you received a signed and dated copy of the contract that includes this notice. Include your name, youraddress, and the date you received the signed copy of the contract and this notice. If you cancel, the contractor must return to you anything you paid within 10 days of receiving the notice of cancellation, For your part, you must make available to the contractor at your residence, in substantially as good condition as you received it, any goods delivered to you under this contract or sale. Or, you may, if you wish, comply with the contractor's Instructions on how to return the goods at the contractor's expense and risk. If you do make the goods available to the contractorand the contactor does notpick them up within 20 days of the date of yournotice of cancellation, you may keep themWl hautrYlathef obligation. If you fall to make the goods available to the Contractor, orif Our? .r1W to contractor and fail to do so, then you remain liable far performance of all ob/igati s under theh�o OOa tto the i, the customersystemr HVAC wish to valve my right to cancel due to art Imrnedfaie%roar enr Air conditioning system lnstallaj`io to waive my right to can home. I will provide Esser with a handwritten walgver of medefor an �� h Wfos ro Q'R+ricYsawrFarsw ai4rfonrory �whhinrhe3 y quest Cusiomer5rgnature., d vperr r Date: r� c>01KC,E ORID£it5 the part'sasl prtof to 4RIt AND red in writing and signal by a the A typiE AS fcltTttJ+tN sihrs the stairs ttE the exile work at ohsng s+ of the contract onto h n de, Claw dart �ttsdula DI piflgtess �sj rflellts Erua weeds and Gbangu Orders ad saw chatt4le otdes.Tha commememe nl 01 aily vfolts '+B cost to be added Of subtraetedfrom the rtinuad, and the of{ the alder will hew+ ot1 E,XCIUslrmr: on the table rides i{self In b$ing upfront width ifs cualosners and ptodny t ery re -able Estimating in the aonstruCiion tield, by nehsre is very ilrtiittx! to wtsei ors *iooflthings that o see at please Note: Next is: Custosrser ding work. Case p Tile balow exdusionss are a dasCripl prkor to signing a pfopoeal ur shading work. ing we are not able 10 sea. once the equipment Ia the time of the bimaun. W � a lhte eo id nS�sslhamovad. ll is very rare that Esser AC Sinda serious issues vm Mi(3HT possibly otential obslade before she lnsta9 is pedormacf- Each OF 11t8 halsnrr ate tsutssse to undhIdnol ramoved, as ym do our best to catch every potential she right to cancel the contrart as any "me for any reason, £slat is under no review on a case by case bOss• Esser uiltmatety ak wetk aoovn obligation to absorb the toss of extra work naaded OUTSkDE the wsilto" scope ()stutter to provide the la11owing,015clalm0rs 1. HERS duct rater of needed) Sea P.2 2. peitorrsted e y I It be (*fling you hin ld weeks at your installallen gad In pro oral} 1. they wr1l isa tailing y aid for by customer unlbisa dharWW spec P 2, 3[750,f10 Per sysfam SoesldenSlat only, p for business unless oShervRsa spas filed in pto"t) 3. $300A10 pa syeranr {cnmmerrSal only, pa by 3, Ag upgrades !01he mf stern or jr,traita ifiet era nrN listed in the prdprrsut. WjIosal- 1, Esser will be using existing HIGH and LCAN voltage wiring. unless t during I statigliopeoitriod iif its ovem n prop is I. Like of"I items, the lour voltage vAthfg may ba condemned�uti11 Sn9lo��ihu lid to � ily kts aliarsi flpotential�issuen. be poor and not in usaabla oondillun- Continuity Ding Sometimes low voftago ahodc may not present lhernseives during the lime of lnstalloWil. If lour vcltapa VA rir+f3 is not listed in She soaps of wvk, d may be subjected to extra costs v BS Y at the time of 2. Hovwsvar, not all issues are able to be dalaoted. in fact, the low voltage wire may be okay installation and da$orl laser. Existing items aro net coverad undar warranty_ High wattage to be referred out to a licensed aW tcian at She owner's exponse- 2. Condensatlan piping ondror dr�mlrsg sycte[m- ifted in ptolwsal- 1 Esser will use existing oo ndensate, unless otnarvJsse spec !- If it is discovered the condoneate Is nol in reusable condition during installation, installation of new condensate pipe will be Subject to extra cost. 2- Often there is no way 10 predict a condensation plug er bicckuut She Ifrrea rofginstatinn�br tr W� co will aMnya make sure that iha system is drain nproperly ed mere are loin many outside q�rttalnly nn posalhin wavy Inn guarantee that it al slay unplug8 factors, separate from the installation tltal could cause drain VSstrea. 3- in the rase of condensation drain blockage or leak due to oulside uedom, Esser vAll not be held responsible for repairs needed to drywafl, paint, StG. 3. Esser will be using wasting ducting. unless otherwise apeciliad in Proposal. 1. Ducting recommendaiions will be made and are a separate Item from the equipment install. 1. ALL ducting upgrades wilt be subjecl lD extra cOw, 2. NOTE: Oucitrig may not 06vays he accessible. If a furs is root accossible. it will not be replaced. 3. If HERS cannot pass "PeMuxr, extra mpaIts and replacumenis amsubject to oxIM costs. 4. Esser will Ase specified in Pro n upgrad� [o axmiir line g a e sat vAft haunless m b*t 1 extra cost rrsal. 1. 2. Fg r line sets [nay be condemned during the Installation prpcess anao 2. Note: pus i lop nature of our work, per tubes are further inspected- th9 System Is aliened up and the copper 4. Esser is not responsible for pred%istlnp ptetformfroefing damage or conditions 1- During Instattalian, if Esser installers deems the platform unstable orin poor c andilion, the upgrades and repairs will tier subject 10 extra cast. he 2• Ptease understand Dial Esser can only do a vlsuaPl�x are pnot coin dad tuniosrsot other specfiedl �tfortn slat can do a furiher inspection of the pleonns integrity. 5. Installation work: 1. Esser not responsible for paint malcWN or painting anything that needs touch up pains. 2. Installation are to be performed be Mon normal working hoursunlessothorvAsse approved. BAM-5PM WF 6. Warranty Walk: 1, Warranty work is only done 730AM-SPhli M-F. 2. Warranty work is not completed on recognized zed tire not included in Esser warranty. s. 3. ;tams not rcla#rd to installation spa 7. payment: 1. Payment Is due upon completion of work within 10 days. 2. Lien releases are not provided unlit pay rront is received and procer wid a. RepairstmodHlcatlons Including roofs, landscaping, ?wires lxrrted udder insulation or the ground, w}ndov+s eic. 1. Extras foaming, Tar, life roof, Interim paint, extedof }rain!, or anythfng not listed in the propel• 1. if vrorking an tile real, hontonwner or HOA must provide reasonable access Aver the the roof. If "'or" nu reasonable access to the unit on ills roof. and tiles are broken, Esser AC vrill riot bar )told roapo 2. Roof screening, Esser will crse existing screening on roof or front yaed. Hov+ever, if no screening oxlsls, than oustomer will be respnnslble for hiring and providing code compliant scree a[rig wound the condenser ar package unil Oil the roof or ground. 9. Home intelligence: Customer is responsible for nolityin9 Esser of a pia-exW ng homy Vnlelhganoeemaniladng system prior to Esser Insfsiltation von wrillen notice. Maxie Z- wgve Ise proprietary and on compatible I flh the Neiria platform at this time. Esser Mil not be hold liable for any changes or modlfiearions needed in order to have a compatible home Vntalifgence system. However, if -Iotifled prior to installalbn. Esser may be able to offer compatible solutions. a door openers, 1. Nexia Membership: is FREE for baSfc rhesmoetal use ONLY. For mist items (cameras, locks, gerag switches etc) a monthly $10.00 fee Is charged by NEXIA. Thiu is aubjact to change at any liana and sal aralo ffom Esser entirely, 10. Altic Entry#fateh: Esser will hake the pfoper slops to ptol6d the ajflc halch. Flow mr, damp to l0 nt is Ipevdable• Esser 11 and 411 roar Hd hold rssparslb is fa the re -pal Ang ornspaks needad arwd the Bilk lfak 1. OWWrt0 bejV,%V!!$Jbb oar, the 18p8ft ra patrol arrd drywall after Inslulirrh'an, r- Minq payment from Esser arse lRslalrialloR,,i COMP181e Cod dead to sc wlce charges for fate payrrtenl aAur 10 days pia lien against the pWrty. Ex7ENG 0 WAR+i'iAAtVrtss: Exrerrded xnr,an[ies are s cusromerc, great assay to remain free of impair hills and comrnonly purchased by our "OTE: tvvloe a year rrr Werrance MUST he done in order to knep yvdrrartfy s+atfd. L1kA 8n of; chafrga far your car. AG Ask ours !nest be o,a t,, it rrr, and rdr oven lire basic rrranufaclurer svarrsniy to be veiki, The Saone goes for extended warranties. Ask our, e$toe aborri our great flrzd etlardablo ways fe keep your sysiam mairHained- Customer Initial: .44 .d