Loading...
BPAT2019-0061ce4ty, 4 4 041ato DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT PATIO COVER/CITY STANDARD/PRE-ENGINEERED - OPEN BPAT2019-0061 54820 ARISTIDES CT 767790016 ALKHAS / (2) TRELLIS DURALUM (PATIO COVERS AT REAR YARD $12, 000.00 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type/Subtype: Application Number: Property Address: APN: Application Description Property Zoning: Application Valuation: Applicant: Z� H ANDREW FISHER - VALLEY PATIOS INC DBA VALI la RETE & 77971 WILDCAT DR SUITE B PALM DESERT, CA 92211 OCT 0 / 2019 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/7/2019 Owner: Alkhas Family Ab Living Trust 54820 ARISTIDES CT LA QUINTA, CA 92253 Contractor: 0 VALLEY PATIOS INC DBA VALLEY CONCRETE & 77971 WILDCAT DR SUITE B PALM DESERT, CA 92211 CITY OF LA QUINTA (760)203-4313 DESIGN & DEVELOPMENT DEPARTMENT Llc. No.: 937811 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C-8. CS1 License No.: 937811 rt C Date V Contrae,'or: �- OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec, 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). () I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.), (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Add WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. , have and will maintain workers' compensation insurance, as required by ISectfort 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: FALLS LAKE FIRE AND G/1$U9! TV COMPANY Policy Number: FLA000408001 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with tho pr visions. Date: Applica WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the a` ove•mentfoned nperty for inspection purposes. )ate. Signature (Applicant or - ' Date: 10/7/2019 Application Number: BPAT2019-0061 Property Address: 54820 ARISTIDES CT APN: 767790016 Application Description: ALKHAS / (2) TRELLIS DURALUM (PATIO COVERS AT REAR YARD Property Zoning: Application Valuation: $12,000.00 Applicant: ANDREW FISHER - VALLEY PATIOS INC DBA VALLEY CONCRETE & 77971 WILDCAT DR SUITE B PALM DESERT, CA 92211 Owner: Alkhas Family Ab Living Trust 54820 ARISTIDES CT LA QUINTA, CA 92253 Contractor: VALLEY PATIOS INC DBA VALLEY CONCRETE & 77971 WILDCAT DR SUITE B PALM DESERT, CA 92211 (760)203-4313 Llc: No.: 937811 Detail: 240SF TRELLIS PATIO COVER AND 410SF TRELLIS PATIO COVER AT REAR YARD [DURALUM] THIS PERMIT DOES NOT INCLUDE ELECTRICAL INSTALLATIONS. PER 2016 CALIFORNIA BUILDING CODES. Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: 91.00 DESCRIPTION ACCOUNT CITY AMOUNT PATIO COVER EA ADDITIONAL 101-0000-42400 0 $53.67 DESCRIPTION ACCOUNT CITY AMOUNT PATIO COVER EA ADDITIONAL PC 101-0000-42600 0 $40.25 DESCRIPTION ACCOUNT CITY AMOUNT PATIO COVER, STD, OPEN 101-0000-42404 0 $107.87 DESCRIPTION ACCOUNT QTY AMOUNT PATIO COVER, STD, OPEN PC 101-0000-42600 0 $106.26 Total Paid for PATIO COVER / COVERED PORCH / LATTICE 2019: $308.05 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT CITY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $1.56 J Total Paid for STRONG MOTION INSTRUMENTATION SMI: $1.56 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 9 AT7,019 - of Typ. PL Hnsiiaes amour[ WA -,2_01 c� — ooc I SY82 o A(Zi -oES �' GCx' CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE E&LkaSY 2.Wo5T-- AND 410 % -M-.LL 15 RECEIVED OCT 9 2 2019 CITY OF LA QUINTA DESIGN AND DEVROPMENT DEPARTMENT MTM zr �!a � dA rev W CALIFORNIA PERMIT #-�PATSC)11 PLAN LOCATION: Project Description: Project Address: APN #: Applicant Name: 1 �� Iti CD >< Wei" Address:— -7q-i City, ST, Zip: � CA 2-L2=1� Telephone:7(P() ` 0 -j Email: ® VCd M Project Valuation $ Contractor Name: ,� p New Construction: Address: `� `g�� Conditioned Space SF City, St, Zip t� Garage SF Telephone: 06 Patio/Porch SF Email: va\�� Fire Sprinklers SF State Lic: -61bJM City Bus Lic. 11 Architect/Engineer Name: Construction Occupancy: Address: Grading: City, St, Zip Telephone: Bedrooms: Stories: # Units: Email: State Lic: City Bus Lic: Property Owner's Name: q �\-� ew Commercial / Tenant Improvements: Address: r` G v Total Building SF City, ST, Zip Construction Type: Occupancy: Telephone: � — , S CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 Building updated 3-1.1.- 19 OFFICE USE ONLY # Submittal Required Received Plan Sets Structural Calcs Truss Calcs Title 24 Calcs CVWD Fire Flow Letter Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval ` City Business License VALLEY PATIOS LUXURY OUTDOOR LIVING Client: Elizabeth and Ramsey Alkhas Address: 54820 Aristides Court City/St/Zip: La Quinta, CA 92253 Phone: (619) 723-7396 Email: ralkhas@hotmail.com elizabethalkhas@yahoo.com Invoice Tel: (760) 203-4313 www.valleypatios.com 77-971 Wildcat Dr. Suite B Palm Desert, CA 92211 License # 937811 Estimated By: JRN Acceptance By: �"O� Date: 1.10 1 1 01 4 PATIO COVER SYSTEM AS MFG. BY: DURALUM PRODUCTS, INC. POINT OF CONTACTS 5 GENERAL NOTES DRAWING NOTES: �� 1. THE DRAWINGS AND SPECIFICATIONS SHOWN REPRESENT THE FINISHED STRUCTURE, UNLESS OTHERWISE NOTED, AND DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL i..r SUPERVISE AND DIRECT THEVIORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. INFORMATION REQUESTS SHALL BE DIRECTED AS FOLLOW: 40� 2. THE APPROVED SETOFDRAWINGS AND SPECIFICATIONS SHALL BEKEPT ATTHE JOB SITE AND SHALL BEAVAILABLE TOTHE AUTHORIZED REPRESENTATNESOFTHE BUILDING AND SAFETYDEPARTMENT. THERE ZI, � ( IF ( ���t� SHALL BE NO DEVIATION FROM THE APPROVED PLANS AND SPECIFICATIONS WTIHOUTAN APPROVED CHANGE ORDER. CONTRACTORS: PLEASE CONTACT DURALUM 26030 ACERO SUITE 200 PHONE: 1949)305-1150 BUILDING DEPARTMENTS: PLEASE CONTACT 4STEL ENGINEERING MISSION VIEJO. CA 92691 FAX: (949) 305-1420 MATERIAL SPECIFICATIONS: HOMEOWNERS: PLEASE REQUEST ANY INFORMATION THROUGH YOUR CONTRACTOR 1. ALUMINUM ALLOYSJPECIFIEDONDRAWINGS. Fty=28KSIAND Ftu=35KSIFOR ALLALUMINUMMEMBERS UNO.Fty=30KSIFOR DURAKINGANDT6PANS SHOWN ONS3.3.ALTERNATE ALUMINUM ALLOYS STRUCTURAL ENGINEER OF RECORD: DUSTINK.ROSEPINKSE5885 MAY BESUBSFITUTEhFORTHOSESHOWN,PROVIDEDTHEYAREREGISTEREDWITHTHEALUMINUMASSOCIATION,ASTMOREN(EUROPEANSFANDARDS),ANDHAVEEQUALORGREATERYIELDANDULTIMATE POINT OF CONTACT: MARIE-DOMINIQUE SETA, SE 5987 STRENGTHS. 2. CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 2,500 POUNDS PER SQUARE INCH. 3, EMBEDDED STEELM::MBERSSHALLBEHOT-DIPPEDGALVANIZED,ANDCONFORMTOA50DGRADEB.ROLLFORMEDSTEELMEMBERSSHALLCONFORMTOA653-SS(STRUCTURALSTEEL)GRADE50G60. 4. BOLTS: ALUMINUM 30LTS SHALL BE 2024-T4, STEEL BOLTS SHALL BE ASTM A-307. ALL BOLTS SHALL HAVE STANDARD-m PLATED WASHERS. DESIGN PARAMETERS S. SCREWS: ALL SCREW}ARE SELF DRILLING (SDS) OR SHEET METALSCREWS (SMS) IN CONFORMANCE WITH ICC-ES ESR 1976, ICC-ESA 30D6, ORAPPROVEO EQUAL 6. FASTENERSTO WO05: WOOD AND LAG SCREWS ARE REQUIRED TO BE INSTALLED IN ACCORDANCE WITH THE 2015 NATIONAL DESIGN SPECIFICATIONS, INCLUDING PRE -DRILLING OF HOLES. ALL LAG SCREWS SHALL BE FULL-THRADED LAG SCREWS, GOVERN INGCODES; 7. POST -INSTALLED ANCHDRS:POST-1NSTALL.EDANCHORS USED SHALL BESIMPSONSTRONG TIE STRONG BOLT2,STAINLESS STEEL �C SIL i7)f2RE BOLT HA11-BEIN.STAU-E20E THI7HE OE51GNOFATTACHEO AND FREESTANDING COVERS SHOWN IN THIS REPORT COMPLIES WITH THE FOLLOWING CODES: MANUFACTURER'S IP"5TALLATION AND IAPMO REPORT. SPECIAL INSPECTON IS NOTREQUIRED. VW [) l .201Z/2015/2D18INTERNATIONAL BUILDING AND RESIDENTIAL CODES, 8. ALL COMPONENTS MANUFACTURED OR SUPPLIED BYDURALUMANDDESCRIBEDINTHISDOCUMENTSAREINTERCHANGEABLE, jj,(jELGAQING _ -2013/2016CALIFORNIA BUILDING AND RESIDENTIAL CODES, THEY ARESUBJECTTU. (/`�� � -ASCE/SEI 7.10 and 7-16 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, 9. THE SELF WEIGHT OF HE PATIO COVER COMPONENTS IN THIS REPORT CAN BE CALCULATED FROM THEIR SECTION PROPERTIES. ES V RCS RY lli.Wf ET F UAj lP F. \ / -2015ALUMINUM DESIGN MANUAL 10. ROOF INSULATED PANELS(WHERE OCCURS).SEE S3.2AND IAPMO 505. BUILDING DIVISION LIVE LOADS DESIGN PARAMETERS: FOOTINGS: REVIEWED F® B IT IS THE RESPONSIBILITY OF THE ENTITY SUBMITTING THE DRAWINGS FOR THIS PROJECT TO VERIFY LIVE LOADS WITH THE LOCAL AUTHORITY HAVING JURISDICTIDN 1. ALL NEW CONCRETE =00TINGS SHALL BEAR ON FIRM, NATURAL, UNDISTURBED SOIL OR CERTIFIED FILL G®®B 1. IN RESIDENTIAL APPLICATIONS, ROOF LIVE LOAD CAN GENERALLY BETAKEN AS 10 PSF PER IRC / CRC APPENDIX H, SECTION AH105.1ORIBC /CBC APPENDIX 1,SECTION 105.1 1 DESIGN VERTICAL SOIL BEARING PRESSURE IS 1,50D POUNDS PER SQUARE FOOT. 2. IN COMMERCIAL APPLICATIONS, ROOF LIVE LOAD CAN GENERALLY BE TAKEN AS 20 PSF PER IBC / CBC CHAPTER 16 3. DESIGN LATERAL SOIL BEARING PRESSURE IS 200 POUNDS PER SQUARE FOOT PER FOOT OF FOOTING DEPTH. (EQUALS 100 PSF/F x 2 PER TABLE 1806. IS 4h WIND SPEED DESIGN PARAMETERS: 4. THE BOTTOM OF FOOTINGS SHALL EXTEND BELOW THE FROST DEPTH. CONTRACTORTOVERIFY FROST DEPTH WITHAUTHORITY PING JURISDICTION d f �' e flANC B 1. THE FREESTANDING AND ATTACHED COVERS NOTED HEREIN ARE DESIGNED AS "OPEN STRUCTURES," IN ACCORDANCE WITH ASCE/SEI 7. 2. FREESTANDING COVERS SHALL NOT BE ENCLOSED WITH ANY TYPE OF SOLID OR MESH MATERIAL, UNLESS SPECIFICALLY DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER. SLAB ON GRADE USED AS A FOUNDATION SYSTEM:a- 3. COVERS SHALL NOT BE INSTALLED IN AREAS NEAR HILLS, RIDGES AND ESCARPMENTS AS DEFINED IN ASCE/SEI 7, SECTION 26.2, UNLESS SITE SPECIFIC ENGINEERING 15 PROVIDED VALIDATING THE WIND LOAD USED. IN ACCORDANCE WITHIRC/CRC APPENDIX H, SECTION AH1105.2, AND IBC/IRC APPENDIX 1, SECTION 1105.2, IN AREAS WITH A FW OEM 1 l 4. THE BASIC WIND SPEEDS CONSIDERED IN THIS REPORT ARE 110,120,130 MPH, EXPOSURES BAND C (BASED ON THE 20121BC, 2D15/20181BC/IRC, 2013 CRC, AND 2016 CBC/CRC). TO AN EXISTING CONCRETE SLAB PROVIDED THE FOLLOWING: S. FOR USE WITH THE 20121RCAND 2013CRC, DIVIDE THE ABOVE MENTIONNEDWIND SPEEDS BYSQRTQ,fi. 1. THE SLAB ON GRADE 15 ATLEAST3 1/2 1NCHESTHICK. SEE DETA11.3 ON S7.2 OR L7.2 AND DETAIL 4 ON S7.1 OR L7.1 FOR REQUIREMENTS FOR THICKER SLAB. WIND SPEED (SEE NOTE 4) 11OMPH 1 12qMPHIII MPH 2. THE SLAB ON GRADE SHALL BE CONTINUOUS BETWEEN COLUMNS AND A MINIMUM OF 10'-0" WIDE. WITHIN THIS AREA, THERE SHALL BE NO CRACKS WIDER THAN I/4"ORCONTROL/EXPANSIONJOINT EQUIVALENT 20121RCJ 2013 CRC WIND SPEED BS MPH 93101 MPH DEEPER/WIDER THAN 3/4". EXAMPLE: IF2032 IRCOR ZOU CAC WINOSPEW 1535 MPH, THE SELECTIONS INTH15 REPORTSHA.U, BE MADE FORA WIND SPEED OF 85 MPH / SQRT(O.6) = 110 MPH. 3. THERE SHALL BE A 6' MINIMUM DISTANCE BETWEEN ANY ANCHOR BOLTAND A SLAB EDGE, CRACK WIDER THAN 1132' OR CDNTROVEXPANSION JOINT DEEPERTHAN 1/2-. SEE DETAILS 4 ON 57.1 OR L7.1 FOR EXCEPTION TO MINIMUM EDGE DISTANCE. SNOW LOADS DESIGN PARAMETERS: 4. THE MAXIMUM DEAD AND LIVE/ SNOW LOAD AT EACH COLUMN 15750 POUNDS WHEN LL=IOPSF. IT 15 THE RESPONSIBILITY OFTHE ENTITY SUBMITTING THE DRAWINGS FORTHIS PROJECTTO VERIFYSNOW LOADS WITH THE LOCALAUTHORITY HAVING JURISDICTION. S. DESIGN FOR PATIO COVERS SUPPORTED ON CONCRETE SLAB ON GRADE 15INACCORDANCE WITH 2O12/2015/20181RCAND2013/2016CRCSECTIONAH105.2FOR10PSF RESIDENTIALCONSTRUCTION,AND SEE SHEETS L2.1 AND L2.2 OR L2.1 AND L2.2 FOR SNOW LOADS DESIGN PARAMETERS. ACI 318-14 FOR 20, 25 AND 30 PSF RESIDENTIAL AND COMMERCIAL CONSTRUCTION. SEISMIC LOAD DESIGN PARAMETERS: � SEISMIC DESIGN BASE SHEAR:17POUNDS PER LINEARFOOT ALONG THE SUPPORTING BEAMS, CONSIDERING A24'-0" MAX SPAN BETWEEN BEAMS AND THE FOLLOWING DESIGN PARAMETERS: NOTES TO LOCAL AUTHORITY I/ HAVING JURISDICTION LASS: D 2.SEISMIC E GNCATEGORY:E AND ENTITY SUBMITTING DRAWINGS FOR APPROVAL 3. MAPPED SPECTRAL RESPONSE COEFFICIENTS: Ss =1.50, S1 = 0.5, Sds =1.0, Sd1 = 0,50 4. RESPONSE MODIFICATION FACTOR, R=1.25 S. RISK CATEGORY 11 USE OF THIS SET OF PLANS FOR ASITE SPECIFIC PROTECT: I. FIOT PAGES DF TH9 WPMO REPDRT WILL BE USED FOR A SITE SPECIFIC PROJECT. EACH PROJECTSUBMITTED TO THE LOCALAL THORITY HAVING JURISDICTION SHOULD INCLUDE ONLY 6. THEPATIDCOVERSTRUCTURESDETAILEDINTHI55ETOFPLANSAREINCOMPLIANCEWITHASCE7-10SECTION12.8.1.3.ASARESULT,THISSETOFPLANSCANBEUSEDATANYSITEWITHSs>1.50,CONSIDERINGSs= THE PERTINENTSITE-SPECIFIC STRUCTURAL COMPONENTS LOCATED WITHIN THIS APMO-LISTED EVALUATION REPORT. 1.50WHEN DESIGNED PER 2012/2015/20181BC/IRCAND 2013/2016CBC/CRC 2. ALL ITEMS PERTAINING TO EACH INSTALLATION (TYPE OF ROOF PANEL, HEADER SPAN, COLUMN SIZE, CONNECTION DETAILS ETC) SHALL BE CIRCLED AND CLEARLY IDENTIFIED BY THE 7. THE PAT10 COVER STRUCTURES DEW LED IN THIS SET OF PLANS ARE IN COMPLIANCE WITH ASCE 7-16 SECTION 12.8.1.3. ASA RESULT, THIS SET OF PLANS CAN BE USED AT ANY SITE WITH 1.0<Sds<1.428, CONSIDERING ENTITY SUBMITTING THE DRAWINGS FOR APPROVAL. Sds - 1.0. FOR SITES WITH 54cj.O, USE Sds. FOR SITES WITH Sds>1.428, IT IS ACCEPTABLE TO REDUCE THE SEISMIC LOADS USING 0.7 Sds INSTEAD OF Sds. 3. PLEASE NOTE THAT4STEL ENGINEERING GENERATED AND STAMPED THE ORIGINAL IAPMO REPORTAS AVAILABLE FROM iAPMO DIRECTLY, BUT WAS NOT INVOLVED IN MAKING ANY SITE B. MINIMUM STRUCTURAL SEISMIC SEPARATION BETWEEN EXISTING BUILDING AND FREESTANDING PATIO COVER SHALL BE 4" AT 10'HIGH MAX PATIO COVERS AND 5" AT 12' HIGH MAX PATIO COVER. REFER TO STATE SPECIFICSELECTIONS OR ANOTATIONS ON THOSE DRAWINGS. ANY HANDMARKING OR HIGHLIGHTING ON THE SITE SPECIFIC SET OF DRAWINGS ARE THE RESPONSIBILITY OF THE ENTITY AND CITY CODES FOR OTHER SPACING REQUIREMENTS THAT MAYBE MORE STRINGENT. SUBMITTING THE DRAWINGS FOR APPROVAL 4. EACH INSTALLATION SHALL BEAR AN IDENTIFYING TAG INDICATING THE NAME AND ADDRESS OF THE MANUFACTURER DESIGN LOADS AND ENCLOSABILTIY. OTHER DESIGN PARAMETERS: 5. THE ORIGINAL IAPMO REPORT BEARS AN ELECTRONIC STAMP FROM 45TEL ENGINEERING, AND A WET STAMP IS NOT REQUIRED IN ACCORDANCE WITH THE REGULATIONS STATED BY THE 1. DESIGN LOADS COMBINATIONS ARE IN ACCORDANCE WITH IBC AND CBCSECTION 1605.3.1 OR 1605.3.2. PROFESSIONAL BOARD OF ENGINEERS. 2. ALLAPPLICABLE REDUCTION FACTORS DETAILED IN THIS REPORT ARE CUMULATIVE 6. A COLOR COPY OFTHE ORIGINAL PAGES FROM THE IAPMO REPORT 15 NOT REQUIRED, A COLOR COPY OF THE CONSTRUCTION DOCUMENTS MAY BE REQUIRED IFSELECTIONS WERE MADE 3. SOLID AND LATTICE ALUMINUM COVERS ARE CLASS A ROOF ASSEMBLY IN ACCORDANCE WITH SECTION CBC 1505.2, EXCEPTION 2. IN A WAY THAT WILL NOT BE VISIBLE ON A BLACK AND WHITE COPY DESIGN ASSUMPTIONS: ATA MINIMUM, SUBMISSION FORA BUILDING PERMIT MUST INCLUDE THE FOLLOWING INFORMA71ON FROM THIS EVALUATION REPORT: 1. MINIMUM ROOF SLOPE FOR SOLID ROOF PANELS WITH DECK: SEE DETAILIB/53.2 L TIRE SHEET AND GENERALMOM SHEET. 66.1 2. MINIMUM ROOF SLOPE FOR SOLID ROOF PANELS WITH DURAPANEL: SEE DETAIL 1A/53.2 2. IAPMO APPROVED SHEET 60.2 3. MAXIMUM ROOF SLOPE FOR ALL STRUCTURES IS 3 DEGREES 3. STRUCTURAL CONFIGURATION (LP SOLID OR LATTICE ROOF, FREESTANDING OR ATTACHED), SHEETS1.x OR L1x 4. SNOW LOAD DESIGN SHEETSS2.1ANDSZ.2,WHEREAPPLICABLE. ❑ STRUCTURE" SHALL BE TAKEN WENT ISWSTANCERDLESS FRODNG VERINGTING INCL FROM ONE D OF OFSWITIOCOVERSLLISAN DECKREAM OTHE OTHER, OFUSEDONTH SAME ANY 5. BASED ON THE REQUIRED DESIGN LOADS,SITE-SPECIFIC RAFTER AND/OR PANEL SPAN TABLESS3xORL3.x BEAM SPLICES. THE STRUCTURE LENGTH SHALL BE DETERMINED THIS WHY REGARDLESS OF ROOF COVERING TYPE, INCLUDING COMBINATION ROOFS WITH BOTH TRELLIS AND DECK ROOF USED ON THE SAME CONTINUOUS PATIO COVER STRUCTURE. HOWEVER, PORTIONS OFTHE STRUCTURE DESIGNED AS LATTICE COVER SHALL NOT BE COVERED BY ROOF DECK. 6. TYPE OF HEADER, POSTTYPE & QUANTITY, FOOTING SIZE (WHERE REQUIRED) BASED ON THE SITE -SPECIFIC DESIGN LOADS. ce S. CALCULATIONS FOR MAXIMUM SPANS WHEN ATTACHING TO AN EXISTING ROOF OVERHANG, AS SHOWN ON TABLE 1ON56.LAND/OR L6.I, ARE ASSUMING THATTHEEKISITNGWOOD RAFTERS ORTRUSSES ARE 7. APPROPRIATE STRUCTURAL DETAILS. a DOUGLAS FIR -LARCH Not. THIS TABLE CAN ALSO BE USED FOR OTHER WOOD SPECIES WITH Fb >_ 900 psi AND Fv>_ 180 psl. B. OTHER DOCUMENTATION THAT MAY BE REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION, SUCH AS SITE PLAN. Uj 9. SEE Sl.x OR L1.x FOR SHEET INDEX W C" SHEET INDEX SEE SHEET St.x OR L1.x FOR SHEET INDEX. ALL UNUSED SHEETS SHALL BE REMOVED FROM THIS SET OF DRAWINGS. JOB NAME: R { s JOB ADDRESS: ` 5q c,C- WIND LOAD: LIVE 1 SNOW LOAD: W N s ct LLI 0 Acj c.A 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 S 58 5 `� OF CAL\FCC' DATE SIGNED: July 8, 2019 rr ZAA-U�Ft:i 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 �Ap Mp ES TM EXPIRES ON: JUNE 30, 2020 REVISIONS MARK DATE DESCRIPTION 4 STEL JOB # DA02-02 DATE 07/DB/19 DRAWN BY RC CHECKED MOB IAPMO 195 V 3.1.1 TITLE SHEET, DESIGN LOADS, GENERALNOTES GO. 1 r v 0 0 � PATIO COVER SYSTEM AS MFG. BY: DURALUM PRODUCTS, INC. � u . }- EBEVALUATION REPORT 195 ,j'ti.• p Originally Issued: 0610112011 Revised: 0711B2019 Valid Through: OW3012020 DURALUM PRODUCTS, INC. 249S Railroad Street Corona, California 92590 (951)736.4500 ua.duruluut.rluu RESIDENILILL PATIO COVERS; CARPORTS, AND COMMERCIAL ROOF STRUCTURES CSI Secllam: le 73 00 Prot-W, Covers 13 34 00 F.Irdimed F.gioemred Sfmclures 1.6 RECOGNITION 1.1 Patio Covent: Duralllm Products Residential Pado Covers recognized in this report have been evaluated for use for recccaunml, outdoor living purposes associated with dnxllingus iµ1nd oohs carport, rArJaM misusage rooms an hibiwble foams. The Rc.idenl kl Patio C cvas compy, w tth Appendix I of the fBC And CBC. and Appendix 11 of the IRC And CRC 12 Grpurhi And Commercial diaof Structures: Duralum Products Carpons and Commercial Roof Swurltucs mogei" in iN s,"poor have been evoltaled rar use witerc permitted by rho spPFnlbk chaptns or the iBC, incloding Soclamu 4% And 1105, Caryvats uumislcd wilb ons- and Iwo-fmuly dwelling units arc for use, where permitted by the IRC or CRC, ineludirg Seelion R309. 1,3 Compliance; -flit stm vurA pmpen In of the Restdmdal Pali¢ Corer. Cotpnnx aid Commercial Roof Struclums ,..%A6.d in Ilk virpmri wvre nwYwud fa eemplismm wish )he following codes And Mulatow: 2018, 2015 and 2012 International Building Cod' (IBC) • 2Q[IIII11R. 2015 and 2012 International Residential Code' 20Y6aad 2013 Califomio Building Code' ICBC) • 20t6•and 2013 California Residential C-odc` (CRC) • ASCE 7-16 and 7-10 - Minimum Design Loads For Buildings and Other Structures ADM I-20 t 5 - Aluminum Design Manuel Pon 1 7- 0 LMUT"TIONS Use of the Dumium Products Residential Patio Covers, CarpoN, and Cmamtorrial Roor5lnMencs rreogoidd m air rcporl and deuRed in the ahaehcd plans end ipeeificativns Rnis;on V3.1,1 signed and datrd July S. 2019. Is subject to the following limitations: 2.1 L'onsrruchim of Ila regldenl ial patio tours. carports and conhmcrci.l roof auuclurcs stun comply with lbc uppl;cable eudra, nmm.fxtucr'. insµll.rm inctmetions, this report and the aceaugtsaiing plans, bearinY the name Dural.m Produets, 1.4, sod 45TEL Engir.veri.. Mere mKIE u occur, the come Tearinive.hsll govern. M PAhio cnvsn sbu0 he msewiawd wish one- ar iwo-fom;ly rhicOlmg .ail* only and shall be lintr d to u.e u sti.el ores regulated under Appendix 1 of the IBC or CBC or Appendix 11 of the IRC or CRC. n Carpons and commercial roof structures shall be limited to.seat slrwures mgul.md by the applicable chapters orlhe IBC far Risk Canary D in ernrdanee with Table US-1 of ASCE 7. Carporra associated wilh one- avid Irmo-bmily dwelling units cbell be limited to use us stmclume regulated by the applicable chapim of the iBC, IRC. CBC and CRC 14 Construction documenu submilled to the building olYcial For uppmral shall include this report and the silo -specific euuk uml components of Ibe acwlupanying plat:, including but unt limited to the rite shcL: gcr" roles, applicable code, structural ...rigumlbm, design criteria in Seelinn 3.1 of this report, related span tables. header, post And footing lypm And appropriate structural dolails. LS The riistlnp smxtum shall be odequake to support the addieivaed leads imposed by the anschod patio cover L6 rw patio covers. ca and commercial moor 'mueowee xubjeet to snow delERng and sliding, whulmed sports shall be modifnmd in uconlance with the mcloninn floats shown in the accompanying plans. 2-7-The pmj zion over length ratio orollwhed pdtit, rovers simo not cxcnd 2 _�f ;Toe using design for nuarhed polo covers And no be increased to 4-0 Aim using column and Fouling sin, nor frccaaudiny atructurn. The projection over Imillh mkt, for freeumuding corm is oat limihcd 2A Reva nding and unachcd patio covers ;.Paris. and coounvcial structures shall have A rmf slope of .1 bast '. inch per fool (1053 percen* L9 For attached polio corns, m6lint Yrunus� Anll Love A minimum width of 30 reel t9.7 an), a-,, um berigdh or So Feet (36.6 an). meat our height rf 22 Feet (6.9 m) or less in Exposure Category B and 15 fen (4.6 m) or less in Lrvposare Category G .ad a mof slope of m 12 to 6:12 (12-5 to 56 percent), Minimum doe armorovedt ogs is 50 square feet ��� rwas•a+�+rar new.,s..e.a.sa...na;awr��r,....s..r....w„rt..rs.v,s�wr•r,wa,...,..w,e,awrr�vn .era,.......,.ewvsr�araa-.. ••.e....nssw h.......rw..rs+e.wn»�eare..v,,..ry..b,'...... w..e..vw. ,h.,ra .>•a.wr.avao,+r.wawr..o.«aea.aa huh. r. aw-.e •veysa errrma °boiees,. uamsww rerm�n¢srwr.sasos.�n,nr rPnn �u�. �e� R a`"as rewa"�'wa..aww a""�.c a�"0u...'�e uni`� Pape life """�, r IAPMO APPROVAL dr. Ut . g 1 REPORT 195 Originally Issued: B51012011 Revised: 071IRMOIS Valid Through: 06/302020 Mir rrecit"ing co m atLwIwd mum end the eiciming buildlgw uaihkch roan ore altaehed thsil comply with the ,'aping rryuirem-ter of'C7apler 25 of ASCE 7 for regular geometric shape and tesparrse elmnrrensrica All hfrn-mum design of live load is 10 psf(47-OS Pa) For patio covers; *mrumd with a ane- and tw'o•family dwelli or unit and 20 psft95-76 PA) for sarituru and conunmial roof Flnuctures. 7-12 IdsWlation of from-plastie-cure hoof panels shall he in accordance wish hs nxkwrion report Section 4.2.4 of this repose. and provide ectulwIcnl vvrtkcal and lalcral load capd Ay a%shown in suds rcpalt 3.13 Approved scalmt or eou)king ;hall k .sr4 at any pencualiomt made in the exl;dng weeahn msitani exterior wall envelope, %A4 Rok lmi.1 Patio evverrr earlimu erd omtm ociA roof slmcltr" suhjoet 10 trpoliropluc efforts of ahrupt change; awh a$ wiad'spted-up over b)11a, ridges and ucorpmenk in accordance with 9mlian 26.5.1 of ASCE 7 are outside the scope of this report. L15 Anymar*intciurceansrea'ted in on one wilho Rai roe r• lap snow load greener OW" 70.6 pO 0380 Pa) in Seismk Design Categories A. B. C. D, D0, DI, D2, E . F, and not complying with Eteeeplion I of IBC or CBC Section 1613.I, is outside the scope of this report. LJ6 Addition ormloaum wails to widential pnio covers fhdl be in accordance soh Seeriorh 4.1 offhis report. 7.37 Tor Dural- Producls Reaidenti! Patio Covers, Copotss, rod Cmmarharul Roof Strum my an; produced in Comm. Cr 201 and $aeantenlo, CdifhmL. 3.0 PRODUCT USE osign athd installation ardor Duralum Piaducis Residential PIatio Covers, Carpons, and Commercial Roof Structures shall comply with the applicable coda, the monufacturct s inmolla;nn insi unions_ this report and the accompanying plans end spec ifamimi Revision V3.I3, signed and dared July 9, 2019. Alt allowable loading cendirions shall be as noted in the plus a compy pag ibis report. Wimme Cm9iets occur, the more resirinh+e sba0 gnvanc 3.1 AuSgat Selecrion of upplloable structtrul caatpanenls for rho installation of fteestanding and elimbed resideminl patio towm cespixu and rommercial roof structures shell be inaeramdaaher wihh Ihedesign criteria is 4pncIfia in the plarn ateafnpany;ns this tro report. The project locanne. t {pa0a Cava. Capon, coanrn-ticlaI stnxtum} ronnpooding code, and applicable design criteria, including risk c.tegory i IIIC only), wind rp" xiod exposure cmum M, oaf live laid, xround now load, x6ornk design calcgnry, ail ream her depth shall be ptacad on or be slucloW to the pltets Acwmpsr.*g ibis mporl and be abuesred In the edccti oo of die compmenlz 3.2 lastdtwilon: Installation ofthrenmimumunis del2rmlhrd in Smien 1A of this rupan to Onwinwl rot patio cover, nrpmt oroommcrc;.l roof an cture slsll be in .ecordom. with this report, the plum necompanying this report, manufacluna's inytalludon inshucliom and the applicable codes of this report. %Vhcrc conflicts occur, the more re.hinive shell goYem 4.0 PRODUCT DFSCRTPTION 4.1 Predict [or nrme 116. Duralum Products Residential Patio Ccry r Carporss, and Commercial! RmrSuwuma arc freaq-di ng and attached min-rncloied solid and lattice nsidenl'Ial patio emsrs; carports and"mmac Lit roofsamcnra Tiwo-dunes ¢lull be constructed in accordance with the plans accompanying dds report and As laaldemrd in this report Anuind Poll* covers, where Considered shall be open on toot oidn. Attached carport. associated with one- and Iwo -family dwelling units shall be open an At least two .ides. Freeslending polio covers, carports and common;el roof strummm shall be open on all four sides. Whine drgrem. cmlmsuae wall cmbfgtrmivna used wish the AnheturY eoenpanrrnts ahemcrtTrd it talc open 0 from mclmd olotcbcd m;dcri 41 polio corer s1s0 conform Ie Ibe limits soled is Sesiion 1103 of the IBC or CBC and Siouan AH 103 of the IRC or CRC. The slrommes shall be futed In a product nvloatiam report from an opprevcd source As dtfsrcd in 1DC and CB C Section 104.11.1 w uthcr nationally recognized eertificulion program aseepµd by IAPMO Uniform Evaluation Service. 42Mat.d.L. 4.2.1 Alumiaom: Alumioom stnm%W ntv&m man roll• fanned or extruded Atapn of vs,lous 011Lyt and lesuperm, complying with C7uptcr N; of tk SRC Nd ASTM WD9 as spcef6ed in tilt plans accompanying dal; report. 4.21 SUkh Sua1 memhme. me Formed from vinia.s grades of Croel eaotplying with ASTM AM Or -do B And AMI A651 SS Grade 50 w4 %+m m deeignsad, witha galvanized mating complying Milt G60, as specified in the pious accompanying Ihis report. 423 Fasteners: F.tmm include aluminum and anal bolls, wood screws. lag screws, post installed arrchors, ne1f4rilling screws and sheet metal screws es specified in the plans acrompeny;ng IIIL TepmL 4.2A Foam-Ploalr-Cure P.-Is: The laminated foam<ore sandwich roof panels used with the smtaural components dc3critmd N olds rayon to farm Oeonsnding and muchcd resddemkal patio and core urcial emcee %hail be Mrapanrl Structural Petrel; fa Patio Coven dm nbcd and mcorni red io IAPMO UL'S ER-505. Paget of 3 n 11. • 195 Originally Issued: 061012011 Revised: 0711W2019 Valid Through: MIJ2020 5.0IDENTIFICATION Enclosures covered by this report shall be identified by a permanent decal or identifying tag that sums the none and address of the monufacttdcr (Dural.. Products. Inc.). Each installation .lull bear on original identifying deed or tag bearing the IAPMO LIES Mari: of Conformiry and the E\uluat;an Report Number (ER-195). Either of the hollering hdarks of Conformity may be used asshoum: (AP�o ups W iAPMO UES ER-195 6.0 SUBSTANTL471FUM1G DATA 62 hold complying Willi the ICC-ES Arc6plmlrc Criteria for Patin Cavaaa"(AC340)_ Apposed August=al lC 62 ingiocm* nkstWons in Accotdonc w10A Ilse 20Ill. 2615 end 20121memaaiwal BW'ld'mgCola. ASCFI-10-4 7-IS and the AMrNnmat 13niRm Msmul Pan I 0 Quality control manual. 6.4 Product drawings. 7.0 STAT'EMMT Of RECOf17TION This eswluatim lepml d---bsa the results of research cirri:-d out by IAPMO Uniform kralomlon Smite on Duralum Products Residential Polio Covnrrt Cotporla end Cmmncmial Roof Structures manufoclured in Comns and Samosa la. Califcmia, so assess their c-lbrunvtce to the codas shown in StIcdaa Lo of this ..pun end docunocots the pntduia s ccrtifsrarioe. The prrdoc ; ore pri,49cd ri lmklars cored In Swim 2,17 of ibis repo¢[ under a quality emend pmgmm with periodic inspection under the supervision of1APM0 UES. Brfn Gerber. P.E. S.E %gc ,1'residem, Technical Operatdns unit.- EealsAHon Survive 1,400� "f"I RleharelBtd, PE, CBO,MCP Via Prey3dtnl, Llaifotm Evulua im Senice K C.`�w jj GP Rant Chanfy CEO, The LAPMO Grasp For •danbW sam-mar p.rI pL-- \idh Page 3 of 3 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 EXPIRES ON: JUNE 30, 2020 REVISIONS HARK DATE DESCRIPTION 4 STEL JOB # DA02-02 DATE 07100119 1 DRAWN BY RC I CHECKED MDS IAPMO 195 V 3.1.1 IAPMO APPROVAL GO.2 9 m I (E) BUILDING RAFTER SEE NOTE 2 r � I RAFTER CONNECTION I TO BLDG SEE NOTE E O z LATTICE @ 3" OR 6 ; D.C.. LaLU w SEE NOTE 2 z ' COL, TYP w a z SEE NOTE 4 j o U cy , w 'o o LU 1 w z RAFTER CONNECTION BEAM SEE NOTE 3 a TO BEAM SEE NOTE 2 BEAM CLEAR SPAN LENGTH 'L' SEE NOTE 1 C PLAN VIEW NOTE$,, 1. PATIO COVER DIMENSIONS SPAN z N A. SEE DESIGN ASSUMPTION NOTE 4 ON GO.1 FOR PATIO COVERS CONSISTING OF SOLID COVERS AND LATTICE FRAMING. B. HEIGHT OF STRUCTURE 'M (TO TOP OF COVER) SHALL NOT BE OVER 12 FT. C. BEAM OVERHANG 'OH' SHALL NOT EXCEED 25% OF BEAM'S ADJACENT CLEAR SPAN, D. RAFTER OVERHANG 'OH' SHALL NOT EXCEED 25% OF RAFTER'S ADJACENT CLEAR SPAN. E. LATTICE OVERHANG 'OH' SHALL NOT EXCEED 25% OF THE TOTAL UNSPLICED LENGTH OF THE LATTICE MEMBER OR 24", WHICHEVER IN LESS. F. TRIBUTARY WIDTH ARE AS SHOWN ON PLAN: • TRIB (Bext)= Y2 ADJACENT RAFTER CLEAR SPAN @ RIGHT + RAFTER OH @ LEFT • TRIB (BLDG)=h ADJACENT RAFTER CLEAR SPAN G. THE RATIO P/L (COVER PROJECTION DIVIDED BY COVER LENGTH), NOT INCLUDING DECK OR BEAM OVERHANG, SHALL NOT BE MORE THAN 2.25 WHEN USING DESIGN FOR ATTACHED PATIO COVERS H. THE RATIO P/L (COVER PROJECTION DIVIDED BY COVER LENGTH) CAN BE UP TO 4.0 WHEN USING COLUMN AND FOOTING SIZES AS IF THE COVER WAS FREESTANDING. 2. LATTICE COVERS A. SEE SHEET L4.1 FOR LATTICE PROFILES. 8. SEE SHEET L3.1F FOR RAFTER PROFILES AND MAXIMUM SPANS. C. SEE SHEET L2.2 FOR REDUCTION OF RAFTER MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEET L6.1 FOR CONNECTION OF LATTICE COVERS TO (E) BUILDING. E. ROOF OF STRUCTURES DESIGNED AS LATTICE COVERS SHALL REMAIN UNCOVERED. THERE SHALL BE NO OBSTRUCTIONS TO THE FLOW OF WIND THROUGH THE LATTICE MEMBERS, SUCH AS FABRIC OR PLANTS. F. CLEAR SPACING OF LATTICE MEMBERS SHALL BE EQUAL TO OR LARGER THAN THEIR WIDTH, AND NOTHING SHALL BE ADDED TO COVER THE LATTICE MEMBERS, THAT COULD OBSTRUCT WIND FLOW, INCLUDING, BUT NOT UMITM TO FABRIC OR PLANTS. G. IF CLEAR SPACING BETWEEN LATRCE FRAMING MEMBERS IS MORE THAN 1.5 11MES THEIR WIDTH (OR ON CENTER SPACING IS MORE THAN 2.5 11MES THEIR WIDTH), IT IS ACCEPTABLE TO DESIGN THE STRUCTURE FOR A GROUND SNOW LOAD OF 20 PSF, EVEN IF THE SITE SPECIFIC GROUND SNOW LOADS ARE HIGHER THAN 20 PSF AND UP TO 84 PSF. 9 ISOMETRIC VIEW 3. BEAMS A. SEE SHEET L4.1 FOR BEAM PROFILES. B. SEE SHEET L4.4 FOR FAN BEAM DETAILS. C. SEE SHEETS 9/0.2 & L8.xx.x FOR TABLES SHOWING MAXIMUM BEAM SPAN. D. SEE SHEET L2.2 FOR REDUCTION OF BEAM MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. E. SEE SHEETS L6.x FOR BEAM CONNECTIONS & DETAILS. 4. COLUMNS A. SEE TABLE 1 ON THIS SHEET FOR MINIMUM NUMBER OF COLUMNS REQUIRED BASED ON COVER DIMENSIONS. B. SEE SHEET L4.2 FOR COLUMN PROFILES. C. SEE SHEETS 9/1-7.2 AND LB.xx.x FOR TABLES SHOWING MAXIMUM POST SPACING. D. SEE SHEETS L6.x & L7.x FOR COLUMN CONNECTIONS & DETAILS. 5. FOUNDATIONS A SEE SHEETS L7.1 AND L7.2 FOR COLUMN CONNECTION TO FOUNDATION. B. SEE BEAM SPAN TABLES ON SHEETS LB.xx.x FOR MINIMUM FOOTING SIZE FOR PATIO COVER SUPPORTED ON CONCRETE FOOTING, BASED ON BEAM SPAN SELECTED. C. SEE L7.1 FOR ALTERNATE FOOTING SIZES. D. SEE 9/0.2 FOR ATTACHED PATIO COVER SUPPORTED ON SLAB ON GRADE. zz N 5E 2 TABLE 1 MINIMUM NUMBER OF POSTS REQUIRING ATTACHMENT PER 3/L6.3 WITH 2 x (1-5 x 0,032 SIDE PLATES (SIDE PLATE TYPE SP3) TRI$ WIDTH WIND 9FEEYAND E)FOSURE 110E 110C 1208 120C 130D 1300 5' 2 2 2 3 3 3 6 2 3 3 3 3 4 T 2 3 3 4 3 4 B 3 3 3 4 4 5 Sr 3 4 4 4 4 5 10' 3 4 4 5 5 5 11' 4 4 4 5 5 5 12, 4 5 5 1 6 5 7 WITH 2 x 6.5 x 0.042 SIDE PLATES (SIDE PLATE TYPE SP4) TRIB WIND SPEED AND EXPOSURE WIDTH 11013 1 11DC 12DB 120C I 13DB 13X 5 2 2 2 2 2 3 6' 2 2 2 3 3 3 7 2 3 3 3 3 4 & 2 3 3 4 3 4 9' 3 3 3 4 4 5 10' 3 4 4 4 4 5 11' 3 4 4 5 5 6 17 3 4 1 4 5 5 5 NOTES: 1. NUMBER OF POSTS SHOWN IN THIS TABLE IS A MINIMUM. ADD POSTS AS REQUIRED TO ENSURE7HATTHE "MAXPOSTSPACING (SPAN)" SHOWN ON SHEETS LB.xx.x IS NOT EXCEEDED- 2. THIS TABLE IS TO BE USED IN CONJUNCTION WITH DETAIL 3/1-6.3. 3. THIS TABLE DOES NOTAPPLY IFTHE SIDE PLATES ARE PROVIDED FOR AESTHETICAL PURPOSES AND THE BEAM IS CONNECTED TO THE COLUMN DIRECTLY PER 2/1-6.3 OR WITH A BRACKET PER 1/1-4.3 & 1/L6.3. A TABLE 1 - MINIMUM NUMBER OF COL REQUIRING TOP ATTACHMENT PER 3/L6,3 SHEET INDEX - LATTICE STRUCTURES: TYPE E GDA -TITLE SHEET, DESIGN LOADS, GENERAL NOTES G0.2 - IAPMO APPROVAL L1.1 -LATTICE STRUCTURES: TYPE E L1.5 - LATTICE STRUCTURES: TRIBUTARY WIDTHS TO BEAMS L2.1 -LATTICE STRUCTURES: SNOW LOAD DESIGN: NEED TO CONSIDER DRIFT AND SLIDING DESIGN L2.2 - LATTICE STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION FACTORS DUE TO DRIFT AND SLIDING L3.1A - LATTICE STRUCTURES: ATTACHED COVERS RAFTER SPANS L4.1 -LATTICE STRUCTURES: BEAM PROFILES L4.2 - LATTICE STRUCTURES: COLUMN PROFILES L4.3 - LATTICE STRUCTURES: CONNECTORS L4.4 - LATTICE STRUCTURES: FAN BEAM DETAILS L6.1 -LATTICE STRUCTURES: ATTACHMENT TO EXISTING BUILDING L6.2 - LATTICE STRUCTURES: CONNECTION DETAILS 1-6.3-LATTICE STRUCTURES: CONNECTION DETAILS L7.1 - LATTICE STRUCTURES: FOUNDATION DETAILS L7.2-LATTICE STRUCTURES: FOUNDATION DETAILS LB.xx.x- LATTICE STRUCTURES: BEAM SPANS AND FOUNDATION SIZES xx PSF LLJSL, 1x0 MPH G9.1 -ADDITIONAL STATE LICENSURE STAMPS LATTICE COVER STRUCTURE TYPE E: ATTACHED SINGLE SPAN WITH OPTIONAL CANTILEVER 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 �FES51z�1 co ' S585 �, yr L1C'T� type' E OF CAbF� DATE SIGNED: July 8, 2019 ;L�Av -.7 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 [*T, EXPIRES ON: JUNE 30, 2020 REVISIONS MARK DATE DESCRIPTION 4 STEL JOB A DA02-02 DATE 07108/19 DRAWN BY RC CHECKED MDS IAPMO 195 V 3.1.1 LATTICE STRUCTURES: TYPE E L 1 . 1 RAFTER p0 SEE NOTE 2 a (E) BUILDING o � � I w RAFTER CONNECTION TO BLDG SEE NOTE 21 Uj m- - r II w cn I LATTICE . 3" OR 6" O.C. v SEE 1NOTE ,2 v COL,{ TYP I I RAFTER MNECi�ON SEE ,NOTE ^^+ g 5 14 TO BEAM SEE NOTE 2' m z I I ] - w 1 BEAM CLEAR SPAN L BEAM CLEAR SPAN LENGTH 'L' SEE NOTE 1 C PLAN VIEW NOTES: 1, PATIO COVER DIMENSIONS A SEE DESIGN ASSUMPTION 4 ON GO.1 FOR PATIO COVERS CONSISTING OF SOLID COVERS AND LATTICE FRAMING. B. HEIGHT OF STRUCTURE 'H' (TO TOP OF COVER) SHALL NOT BE OVER 12 FT. C. BEAM OVERHANG 'OH' SHALL NOT EXCEED 25% OF BEAM'S ADJACENT CLEAR SPAN. D. RAFTER OVERHANG 'OH' SHALL NOT EXCEED 25% OF RAFTER'S ADJACENT CLEAR SPAN. E LATTICE OVERHANG 'OH' SHALL NOT EXCEED 25% OF THE TOTAL UNSPUCED LENGTH OF THE LATTICE MEMBER OR 24', WHICHEVER IS LESS. F. TRIBUTARY WIDTH ARE AS SHOWN ON PLAN: • TRIS (Sext)= Y2 ADJACENT RAFTER CLEAR SPAN @ RIGHT + RAFTER OH 0 LEFT • TRIB (Sint)= Y2 ADJACENT RAFTER CLEAR SPAN @ RIGHT + Y2 ADJACENT RAFTER CLEAR SPAN 0 LEFT • TRIB (BLDG)=Y2 ADJACENT RAFTER CLEAR SPAN G. THE RATIO P/L (COVER PROJECTION VNIDED BY COVER LENGTH), NOT INCLUDING DECK OR BEAM OVERHANG, SHALL NOT BE MORE THAN 2.25 WHEN USING DESIGN FOR ATTACHED PATIO COVERS H. THE RATIO P/L (COVER PROJECTION DIVIDED BY COVER LENGTH) CAN BE UP TO 4.0 WHEN USING COLUMN AND FOOTING SIZES AS IF THE COVER WAS FREESTANDING. 2, LATTICE COVERS A. SEE SHEET L4.1 FOR LATTICE PROFILES. B. SEE SHEET L3.1A FOR RAFTER PROFILES AND MAXIMUM SPANS. C. SEE SHEET L2.2 FOR REDUCTION OF RAFTER MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEETS L6.1 FOR CONNECTION OF LATTICE COVERS TO (E) BUILDING. E. ROOF OF STRUCTURES DESIGNED AS LATTICE COVERS SHALL REMAIN UNCOVERED. THERE SHALL BE NO OBSTRUCTIONS TO THE FLOW OF WIND THROUGH THE LATTICE MEMBERS, SUCH AS FABRIC OR PLANTS. F. CLEAR SPACING OF LATTICE MEMBERS SHALL BE EQUAL TO OR LARGER THAN THEIR WIDTH, AND NOTHING SHALL BE ADDED TO COVER THE LATTICE MEMBERS, THAT COULD OBSTRUCT WIND FLOW, INCLUDING, BUT NOT LIMITED TO FABRIC OR PLANTS. G. IF CLEAR SPACING BETWEEN LATTICE FRAMING MEMBERS IS MORE THAN 1.5 TIMES THEIR WIDTH (OR ON CENTER SPACING IS MORE THAN 2.5 TIMES THEIR WIDTH), IT IS ACCEPTABLE TO DESIGN THE STRUCTURE FOR A GROUND SNOW LOAD OF 20 PSF, EVEN IF THE SITE SPECIFIC GROUND SNOW LOADS ARE HIGHER THAN 20 PSF AND UP TO 84 PSF. OH B [SOMETRiC VIEW 3. BEAMS A. SEE SHEET L4.1 FOR BEAM PROFILES. B. SEE SHEET L4.4 FOR FAN BEAM DETAILS. C. SEE SHEETS 9/L7.2 & LB.xx.x FOR TABLES SHOWING MAXIMUM BEAM SPAN. D. SEE SHEET L2.2 FOR REDUCTION OF BEAM MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. E. SEE SHEETS L6.x FOR BEAM CONNECTIONS & DETAILS. 4__CS ISl NLS A. SEE TABLE 1 ON THIS SHEET FOR MINIMUM NUMBER OF COLUMNS REQUIRED BASED ON COVER DIMENSIONS. B. SEE SHEET L4.2 FOR COLUMN PROFILES. C. SEE SHEETS 9/L7.2 AND LB.xx.x FOR TABLES SHOWING MAXIMUM POST SPACING. D. SEE SHEETS L6.x & L7.x FOR COLUMN CONNECTIONS & DETAILS. 5. FOUNDATIONS A SEE SHEETS L7.1 AND L7.2 FOR COLUMN CONNECTION TO FOUNDATION. B. SEE BEAM SPAN TABLES ON SHEETS LB.xx.x FOR MINIMUM FOOTING SIZE FOR PATIO COVER SUPPORTED ON CONCRETE FOOTING, BASED ON BEAM SPAN SELECTED. C. SEE L7.1 FOR ALTERNATE FOOTING SIZES. D. SEE 9/1-7.2 FOR ATTACHED PATIO COVER SUPPORTED ON SLAB ON GRADE 3. TABLE 1 MINIMUM NUMBER OF POSTS REQUIRING ATTAr.14UFNT PFR 311.E 3 WITH 2 x 6.5 x 0.032 SIDE PLATES (SIDE PLATE TYPE SP3) TRIG WIDTH WIND SPEED AND EWPOSU RE 110E 110G 1208 12DC 1300 130C 5' 2 2 2 3 3 3 B' 2 3 3 3 3. 4 T 2 3 3 4 3 4 8' 3 3 3 4 4 5 8' 3 4 4 4 4 5 7a 3 4 4 5 5 6 11, 4 4 4 5 5 8 17 4 5 5 5 5 7 WITH 2 x 6.5 x 0 Od2 SIDE PLATES - (SIDE PLATE TYPE SP4) TRIB WIND SPE E D AND E XPOS UR E WIDTH I1DB 110C 120B 120C I 130B 13W 52 2 2 2 2 3 V 2 2 1 2 3 3 3 T 2 3 3 3 3 4 B' 2 3 3 4 3 4 93 3 3 4 4 5 10 3 4 4 4 4 5 TV 3 4 4 5 5 8 1-2 3 4 4 5 5 5 NOTES: 1. NUMBER OF POSTS SHOWN IN THIS TABLE IS A MINIMUM. ADD POSTS AS REQUIRED TO ENSURE THAT THE "MAX POST SPACING (SPAN)' SHOWN ON SHEETS LB.xx.x IS NOT EXCEEDED. 2. THIS TABLE IS TO BE USED IN CONJUNCTION WITH DETAIL 3/1-6.3 3. THIS TABLE DOES NOT APPLY IF THE SIDE PLATES ARE PROVIDED FOR AESTHETICAL PURPOSES AND THE BEAM IS CONNECTED TO THE COLUMN DIRECTLY PER 2/L6.3 OR WITH A BRACKET PER 111-4.3 & 1/L6.3. A)TABE 1 -MINIMUM NUMBER OF COL REQUIRING TOP ATTACHMENT PER 3/L62 SHEET INDEX - LATTICE STRUCTURES: TYPE F GDA -TITLE SHEET, DESIGN LOADS, GENERAL NOTES GO.2- IAPMO APPROVAL L1.2 - LATTICE STRUCTURES: TYPE F L1.5 - LATTICE STRUCTURES: TRIBUTARY WIDTHS TO BEAMS L2.1 - LATTICE STRUCTURES: SNOW LOAD DESIGN: NEED TO CONSIDER DRIFT AND SLIDING DESIGN L2.2 - LATTICE STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION FACTORS DUE TO DRIFT AND SLIDING L3.1 A - LATTICE STRUCTURES: ATTACHED COVERS RAFTER SPANS L4.1 - LATTICE STRUCTURES: BEAM PROFILES L4.2 - LATTICE STRUCTURES: COLUMN PROFILES L4.3 - LATTICE STRUCTURES: CONNECTORS L4.4 - LATTICE STRUCTURES: FAN BEAM DETAILS LOA - LATTICE STRUCTURES: ATTACHMENT TO EXISTING BULDING L6.2 - LATTICE STRUCTURES: CONNECTION DETAILS L6.3 - LATTICE STRUCTURES: CONNECTION DETAILS L7 1 - LATTICE STRUCTURES: FOUNDATION DETAILS L7.2-LATTICE STRUCTURES: FOUNDATION DETAILS LS.)(x.x- LATTICE STRUCTURES: BEAM SPANS AND FOUNDATION SIZES xx PSF LUSL, 1x0 MPH G9.1 -ADDITIONAL STATE LICENSURE STAMPS 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 DATE SIGNED: July 8, 2019 v'_7twvc_ TC� 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 EXPIRES ON: JUNE 30, 2020 REVISIONS MARK I DATE DESCRIPTION 4 STEL JOB R DA02-02 DATE 07/08/19 DRAWN BY RC CHECKED MDS IAPMO 195 V 3.1.1 LATTICE STRUCTURES: TYPE F LATTICE COVER STRUCTURE TYPE F: ATTACHED MULTI -SPAN WITH OPTIONAL CANTILEVER L1.2 x m � m 2 E w y j m O PLAN VIEW_ NOTES: 1-PAnO-COVIR _ PIAfMIUNS l- RAFTERSEENOTE 2 LATTICE.@ 3"I OR O.C. SLE NOTE 2 1 1 I - A OL, TYP wE CONNECTION SEE NOTE 2 BEAM CLEAR SPAN LENGTH 'L' SEE NOTE 1 A. SEE DESIGN ASSUMPTION 4 ON GO.1 FOR PATIO COVERS CONSISTING OF SOLID COVERS AND LATTICE FRAMING. B. HEIGHT OF STRUCTURE 'H' (TO TOP OF COVER) SHALL NOT BE OVER 12 FT. C. BEAM OVERHANG 'OH' SHALL NOT EXCEED 25% OF BEAM'S ADJACENT CLEAR SPAN. D. RAFTER OVERHANG 'OH' SHALL NOT EXCEED 25% OF RAFTER'S ADJACENT CLEAR SPAN. E. LATTICE OVERHANG 'OH' SHALL NOT EXCEED 257 OF THE TOTAL UNSPUCED LENGTH OF THE LATTICE MEMBER OR 24", WHICHEVER IS LESS. F. TRIBUTARY WIDTH ARE AS SHOWN ON PLAN: • TRIB (Bext)= )k ADJACENT RAFTER CLEAR SPAN @ RIGHT + RAFTER OH @ LEFT • TRIB (BLDG)=X ADJACENT RAFTER CLEAR SPAN 2. LA710F OOV<RS A. SEE SHEET L4.1 FOR LATTICE PROFILES. B. SEE SHEET L3.1F FOR RAFTER PROFILES AND MAXIMUM SPANS. C. SEE SHEET L2.2 FOR REDUCTION OF RAFTER MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. E. SEE SHEETS L6.1 FOR CONNECTION OF LATTICE COVERS TO (E) BUILDING.ROOF OF STRUCTURES DESIGNED AS LATTICE COVERS SHALL REMAIN UNCOVERED. THERE SHALL BE NO OBSTRUCTIONS TO THE FLOW OF WIND THROUGH THE LATTICE MEMBERS, SUCH AS FABRIC OR PLANTS. F. CLEAR SPACING OF LATTICE MEMBERS SHALL BE EQUAL TO OR LARGER THAN THEIR WIDTH, AND NOTHING SHALL BE ADDED TO COVER THE LATTICE MEMBERS, THAT COULD OBSTRUCT WIND FLOW, INCLUDING, BUT NOT LIMITED TO FABRIC OR PLANTS. G. IF CLEAR SPACING BETWEEN LATTICE FRAMING MEMBERS IS MORE THAN 1.5 TIMES THEIR WIDTH (OR ON CENTER SPACING IS MORE THAN 2.5 TIMES THEIR WIDTH), IT IS ACCEPTABLE TO DESIGN THE STRUCTURE FOR A GROUND SNOW LOAD OF 20 PSF, EVEN IF THE SITE SPECIFIC GROUND SNOW LOADS ARE HIGHER THAN 20 PSF AND UP TO 84 PSF. zz w IN z F W Ir a ISOMETRIC VIEW _. (�,,) 3/32"=l'-O" 3. BEAMS A. SEE SHEET L4.1 FOR BEAM PROFILES. B. SEE SHEET L4.4 FOR FAN BEAM DETAILS. C. SEE SHEETS 9/1-7.2 & L8.xx.x FOR TABLES SHOWING MAXIMUM BEAM SPAN. D. SEE SHEET L2.2 FOR REDUCTION OF BEAM MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. E. SEE SHEETS L6.x FOR BEAM CONNECTIONS & DETAILS. 4, COLUMNS A SEE TABLE 1 ON THIS SHEET FOR MINIMUM NUMBER OF COLUMNS REQUIRED BASED ON COVER DIMENSIONS. B. SEE SHEET L4.2 FOR COLUMN PROFILES. C. SEE SHEETS 9/1-7.2 AND LB.xx.x FOR TABLES SHOWING MAXIMUM POST SPACING. D. SEE SHEETS L6.x & L7.x FOR COLUMN CONNECTIONS & DETAILS. 6t�0 N A SEE SHEETS L7.1 AND L7.2 FOR COLUMN CONNECTION TO FOUNDATION. B. SEE BEAM SPAN TABLES ON SHEETS LB.xx.x FOR MINIMUM FOOTING SIZE FOR PATIO COVER SUPPORTED ON CONCRETE FOOTING, BASED ON BEAM SPAN SELECTED. C. SEE 9/L7.2 FOR ALTERNATE FOOTING SIZES. SLAB, i TABLE 1 MINIMUM NUMBER OF POSTS REQUIRING ATTACHMENT PER 3/1-6.3 WITH 2 x 6.5 x O.W2 SIDE PLATES (SIDE PLATE TYPE SP3) TRIB WIDTH WINDSPEED AND EXPOSUTF- 110E 110C 120E 120C 13D6 130C 5' 2 2 2 3 3 3 6' 2 3 3 3 3 4 7 2 3 3 4 3 4 8' 3 3 3 4 4 5 9' 3 4 4 4 4 5 10' 3 4 4 5 5 6 11' 4 4 4 5 5 6 12' 4 15 5 1 6 5 7 WITH 2 x 6.5 x D.D42 SIDE PLATES tSIDE PLATE TYPE SP4] TRIO WIND 3PEE DAND )POSURE WIDTH 110E 110C 1 120E 120C I 130E 130C 5' 2 2 2 2 2 3 6 2 2 2 3 3 3 7 2 3 3 3 3 4 6' 2 3 3 4 3 4 9' 3 3 3 4 4 5 10' 3 4 4 4 4 5 11' 3 4 4 5 5 6 12 1 3 T 4 4 5 5 5 NOTES: 1. NUMBER OF POSTS SHOWN IN THIS TABLE IS A MINIMUM. ADD PCSTS AS REQUIRED TO ENSURE THAT THE "MAX POST SPACING (SPAN)" SHOWN ON SHEETS LB.xx.x IS NOT EXC-EEDED. 2. THIS TABLE IS TO BE USED IN CONJUNCTION WITH DETAIL 3/1.6.3. 3. THIS TABLE DOES NOTAPPLY IF THE SIDE PLATES ARE PROVIDED FOR AESTHETICAL PURPOSES AND THE BEAM IS CONNECTED TO THE COLUMN DIRECTLY PER 2/1-6.3 OR WITH A BRACKET PER 1/1-4-3 8 1 /L6.3. �ABLE 'I -,MINIMUM NUMBER OF COL. " REQUIRING TOP ATTACHMENT PER 3/L6+3 SHEET INDEX - LATTICE STRUCTURES: TYPE G GDA -TITLE SHEET, DESIGN LOADS, GENERAL NOTES GD.2 - IAPMO APPROVAL 1-1.3 - LATTICE STRUCTURES: TYPE G 1-1.5 - LATTICE STRUCTURES: TRIBUTARY WIDTHS TO BEAMS L2.1 - LATTICE STRUCTURES: SNOW LOAD DESIGN: NEED TO CONSIDER DRIFT AND SLIDING DESIGN L2 2 - LATTICE STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION FACTORS DUE TO DRIFT AND SLIDING L3.1 F - LATTICE STRUCTURES: FREESTANDING COVERS RAFTER SPANS L4.1 -LATTICE STRUCTURES: BEAM PROFILES 1-4 2 - LATTCE STRUCTURES: COLUMN PROFILES 1-4-3 - LATTIC E STRUCTURES: CONNECTORS L4.4 - LATTICE STRUCTURES: FAN BEAM DETAILS L5.1 - LATTICE STRUCTURES: ATTACHMENTTO EXISTING BUILDING L6.2 - LATTICE STRUCTURES: CONNECTION DETAILS L6 3 - LATTICE STRUCTURES: CONNECTION DETAILS L7.1 -LATTICE STRUCTURES: FOUNDATION DETAILS L7.2 - LATTICE STRUCTURES: FOUNDATION DETAILS L8.xxx- LATTICE STRUCTURES: BEAM SPANS AND FOUNDATION SIZES xx PSF LUSL, 1xO MPH G9.1 -ADDITIONAL STATE LICENSURE STAMPS LATTICE COVER STRUCTURE TYPE G: FREESTANDING SINGLE SPAN WITH OPTIONAL CANTILEVER 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 FE SI L!J S 58 5 O� DATE SIGNED: July 8, 2019 VA p , 77f'r 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 I FAX 949.305.1420 S*TM EXPIRES ON: JUNE 30, 2020 REVISIONS rMARK DATE DESCRIPTION 4 STEL JOB # DA02-02 DATE 07108/19 DRAWN BY RC CHECKED MDS IAPM0195 V 3.1.1 LATTICE STRUCTURES: TYPE G L1.3 _ m m w N w I RAFTERi CONNECTION i I I COL; TYP 4 n TO BEAM Sq NOTE 2 1 1 SEE NOTE , -- 1 w y aw RAFTER SEE NOTE 2 v i I { LV+TTIC� @ 3j OR 6. 0.0, 1 r mTiww d SEE NGTE 21 I � I - BEAM CLEAR SPAN L BEAM LENGTH 'L' SEE NOTE 1 C PLAN VIEW NOTES: I. PATIO COVER DIM N I S A. SEE DESIGN ASSUMPTION 4 ON GO.1 FOR PATIO COVERS CONSISTING OF SOLID COVERS AND LATTICE FRAMING. B. HEIGHT OF STRUCTURE 'H' (TO TOP OF COVER) SHALL NOT BE OVER 12 FT. C. BEAM OVERHANG 'CH' SHALL NOT EXCEED 25% OF BEAM'S ADJACENT CLEAR SPAN. D. RAFTER OVERHANG 'OH' SHALL NOT EXCEED 25% OF RAFTER'S ADJACENT CLEAR SPAN. E. LATTICE OVERHANG 'OH' SHALL NOT EXCEED 25% OF THE TOTAL UNSPIICED LENGTH OF THE LATTICE MEMBER OR 24", WHICHEVER IS LESS. F. TRIBUTARY WIDTH ARE AS SHOWN ON PLAN: • TRIB (Bext)= h ADJACENT RAFTER CLEAR SPAN @ RIGHT + RAFTER OH @ LEFT • TRIB (Sint)- kz ADJACENT RAFTER CLEAR SPAN @ RIGHT + )I ADJACENT RAFTER CLEAR SPAN @ LEFT • TRIB (BLDG)=): ADJACENT RAFTER CLEAR SPAN LAlT12 CF CARS A SEE SHEET L4.1 FOR LATTICE PROFILES. B. SEE SHEET L3.1F FOR RAFTER PROFILES AND MAXIMUM SPANS. C. SEE SHEET L2.2 FOR REDUCTION OF RAFTER MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. E SEE SHEETS LGA FOR CONNECTION OF LATTICE COVERS TO (E) BUILDING.ROOF OF STRUCTURES DESIGNED AS LATTICE COVERS SHALL REMNR UNCOVERED. THERE SHALL BE NO OBSTRUCTIONS TO THE FLOW OF WIND THROUGH THE LATTICE MEMBERS, SUCH AS FABRIC OR PLANTS. F. CLEAR SPACING OF LATTICE MEMBERS SHALL 13E EQUAL TO OR LARGER THAN THEIR WIDTH. AND NOTHING SHALL BE ADDED TO COVER THE LATTICE MEMBERS, THAT COULD OBSTRUCT WIND FLOW, INCLUDING, BUT NOT LIMITED TO FABRIC OR PLANTS. G. IF CLEAR SPACING BETWEEN LATTCE FRAMING MEMBERS IS MORE THAN 1.5 TIMES THEIR WIDTH (OR ON CENTER SPACING IS MORE THAN 2.5 TIMES THEIR WIDTH), IT IS ACCEPTABLE TO DESIGN THE STRUCTURE FOR A GROUND SNOW LOAD OF 20 PSF. EVEN IF THE SITE SPECIFIC GROUND SNOW LOADS ARE HIGHER THAN 20 PSI= AND UP TO 84 PSF. #3 180METRIC VIEW 3. BEAM A SEE SHEET L4.1 FOR BEAM PROFILES. B. SEE SHEET L4.4 FOR FAN BEAM DETAILS. B. SEE SHEETS 9/0.2 & L8.xx.x FOR TABLES SHOWING MAXIMUM BEAM SPAN. C. SEE SHEET L2.2 FOR REDUCTION OF BEAM MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEETS L6.x FOR BEAM CONNECTIONS & DETAILS. 4. COLUMNS A SEE TABLE 1 ON THIS SHEET FOR MINIMUM NUMBER OF COLUMNS REQUIRED BASED ON COVER DIMENSIONS. B. SEE SHEET L4.2 FOR COLUMN PROFILES. C. SEE SHEETS 9/0.2 AND L8.xx.x FOR TABLES SHOWING MAXIMUM POST SPACING. D. SEE SHEETS L6.x & L7.x FOR COLUMN CONNECTIONS & DETAILS. 5. _F/] A11014S_ A SEE SHEETS L7.1 AND L7.2 FOR COLUMN CONNECTION TO FOUNDATION. B. SEE BEAM SPAN TABLES ON SHEETS L.B.xx.x FOR MINIMUM FOOTING SIZE FOR PATIO COVER SUPPORTED ON CONCRETE FOOTING. BASED ON BEAM SPAN SELECTED. C. SEE 9/0.2 FOR ALTERNATE FOOTING SIZES. SLAB, TABLE 1 MINIMUM NUMBER OF POSTS REQUIRING ATTACHMENT PER 3A-6.3 WITH 2 x 6.5 x 0.032 S M PLATES (SIDE PLATE TYPE SP3) TRIG 1 WIDTH W IND S PEE R AN15 E XPOS URE SIDE 110C 120E 12DC 130E 1300 5' 2 2 2 3 3 3 6 2 3 3 3 3 -4 T 2 3 3 4 3 4 g• 3 3 3 d 4 5 g 3 4 4 4 4 5 Sd 3 4 4 5 1 5 1B 11' 4 4 4 5 5 6 17 4 5 5 6 5 7 - - -- - -- - WITH 2-x 6.5 x 0.00 SIDE PLATES- -- - (SIDE PLATE TYPE SP4) TRIG I140 SPEED AND EXPOSURE WIDTH 1109 I 110C 720E 120C 130E 130C 5' 2 1 2 2 2 2 3 G 2 2 2 3 3 3 T 2 3 3 3 3 4 8 2 3 9 4 3 4 g 3 1 3 3 4 4 5 IV 3 4 4 4 4 5 11' 3 d 4 S 5 6 77 3 4 4 5 5 5 NOTES: 1. NUMBER OF POSTS SHOWN IN THIS TABLE IS A MINIMUM. ADD POSTS AS REQUIRED TO ENSURE THAT THE °MAX POST SPACING (SPAN)" SHOWN ON SHEETS LB.xx.x IS NOT EXCEEDED. 2. THIS TABLE IS TO BE USED IN CONJUNCTION WITH DETAIL3/L6.3. 3. THIS TABLE DOES NOT APPLY IF THE SIDE PLATES ARE PROVIDED FOR AESTHETICAL PURPOSES AND THE BEAM IS CONNECTED TO THE COLUMN DIRECTLY PER 2/1-6.3 OR WITH A BRACKET PER 1/1-4.3 & 1/L5.3. (�)TABLE 1 - MINIMUM NUMBER OF COL.EQUIRINQ TOP ATTACHMENT PER 3/L8.3 SHEET IND - LA=E STRUCTURES:T)PE H GOA -TITLE SHEET, DESIGN LOADS, GENERAL NOTES G0.2 - IAPMO APPROVAL L1-4-LATTICE STRUCTURES: TYPE H L1.5 - LATTICE STRUCTURES: TROUTARY WIDTHS TO BEAMS L2.1 - LATTICE STRUCTURES: SNOW LOAD DESIGN: NEED TO CONSIDER DRIFT AND SLIDING DESIGN L2.2-LATTICE STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION FACTORS DUE TO DRIFTAND SLIDING L3.1 F - LATTICE STRUCTURES: FREESTANDING COVERS RAFTER SPANS L4.1 -LATTICE STRUCTURES: BEAM PROFILES L4.2- LATTICE STRUCTURES: COLUMN PROFILES L4.3 -LATTICE STRUCTURES: CONNECTORS L4.4-LA7TICE STRUCTURES: FAN BEAM DETAILS L6.1 -LATTICE STRUCTURES:ATTACHIM ENTTO EXISTING BUILDING L6.2 - LATTIC E STRUCTURES: CONNECTION D ETAILS L6.3-LATTICE STRUCTURES: CONNECTION DETAILS L7.1 -LATTICE STRUCTURES: FOUNDATION DETAILS L72-LATTI0E STRUCTURES: FOUNDATION DETAILS L8.x(A - LATTIC E STRUCTURE S: SEA M SPANS AND FOUNDATION SIZES xx PS F LLISL, 1xD MPH G9.1 -ADDITIONAL STATE LICENSURE STAMPS LATTICE COVER STRUCTURE TYPE H: FREESTANDING MULTI -SPAN WITH OPTIONAL CANTILEVER 3:000" O.O 18" 0 0 2 x 3 LATTICE TUBE e E 6'=1'-On 11/2_x11V/2OR2x2 LATTICE TUBE 6"=1'-0" &IUMJ ALLOY 3334-H36 4 0.042 o 0 co ! 3.000" 3' x 8' RAFTER ALUM. ALLOY 3D04-H35 ALUM. ALLOY 3004-H36 T o T o C 2.000"L 6.000" 2.000 d MAX R2 7 x 6S' RAFTER I ��,� DBL 7 x 6N RAFTER 3X8 RAFTER -ATTACHED STRUCTURE a(61/2 RAFTER -ATTACHED STRUCTURE DBL. 2X6 1/2 RAFTER -ATTACHED STRUCTURE LLIGSL T N SPACING OIC WIND SPEED I EXP LUGSL T IN) SPACING OIC . WINOFSPEEDIEXP LLIGSL T (IN) SPACING OIC WIND SPEED) EXP 1105 110 C 120 B 120 C 13D Br 1108 110 C 120 B 120 C 130 B 130 C 110 B 110 C 12D B 120 C 130 B 55 C 10 0.042 16" 29'$:' 29'-6" 29'-8' 28'-9" 29'-3" 10 0.024 16" 1fi-0" 15'-10" 16'-0" 15'-0" 15'-9" 13'-B" 10 0,024 16' 22-6" 22-4" 22-6" 21'-1' 22'-2" 19'-2" 24" 24'-T 24'-1' 24'-2' 23'S" 24'-0" 24" 13=1" 13'-0" 13'-1" 12'-3" 12'-10" 11'-2" 24" 18-4" 1V-7 184" 1T-3" 18'-2" 1V-87 20 0.042 16" 23'-0" 23'-D" 23'-0" 23'-0' 23'-0' 0.032 16" 2U-3" 20'-2" 20' 3" 19' B' 20'-1" 18'-2" 0.03224" 16" 28'-7" 28'-6" 28-7" 2T-9" 263" 25'-7" 247 18'-9" 1B'-T 1B'-9" 18-9.° 18'-9' 24' 16'-7" 16'-0" 1V-r 16'-1' 16'-4' 14-10" 23'4" 23-3" 234" 22'-8" 23'-1" 20'-10" 25 0.042 16" 19' 8" 19'-8" 19'-8" 19'-B` 19' 8" 0.042 1b" 24' 6" 24'�' 24'S' 23'-9 24'3' 23'-2" O.D42 16" 34' 7" 34' 4' 34L7" 33'-T 34'-2" 323" 24" 16-1" 1V-1" 16-1' 16'-1" 16'-1" 16'-1" 24" 2-0'-1" 20'-0" 2V-1" 19'{" 19'-9" 19'-W 24' 28'-2' 28'-1' 28L2' 27-4' 27'-10" 26'3" 3D 0.042 16" 18Li" 1T-1" 18'-1' IV-1' 18'-1." 18=1' 20 0.024 16" 12'-4" 12'-4" 12'-4" 12'-0" 12'-4" 12.4" 20 0.024 19, 1T-4' 1T-4 1T-0" '17 ' 17-4" 1T3" 24" 13'S" 13'-9" 13'-9" 13%9' IT-9- 13L9" 24' 10'-2" 10'-2" Iour 10'-2" 10'-2' 10'-1" 24" 14'-2" 14'-2" 14L2" 1V-2" 14'-2" 14'-2" 40 0.042 16" 15!-10" 15'-10" 15'-10' 15LJ0" 15'-10" 15LI0" 0.032 16" 15-8" 151-r 15'-0" 15'3" 16-8" 15'-8" 0.032 16" 22-1" 22-1" 22-1' 22'-1" 22-1" 22'-0" 24' 12'-1" 12-1" 12-1' 12'-1` 12-1' 12' 1" 24' 1T-1D..' 12-10' 12-10" 12'-10" IZ-10' 12'-9" 24" 18'-1" 18'-1" 18L7" 18L1" 18'-1" 1V-0" 50 0.042 16" 13'-4" 13'-C 13-4° 13'-4" I T-4' 13'-4" D.042 16" 1 W-0" 19'-0" 19'-0" 19'-0" 19'-0" 18'-10" 0.042 16" 26'-S" 26'-W 261-8" 26'-B" 26'-8" 26' 7" 24" 10'3' 10'-3" 10'-3" 10'.3` 10'-3" 10'-3- 24" 15-6" 15'-0" 15'3" 15'3" 15'-b" 15'-6" 24" 21L10" 21'-10" 21'-10" 21'-10" 21'-10" 21'-9" 60 0.042 16" 10'-12" IOL12" 10'-12" 1D'.10" 10'-10' 10'-7" 25 0.024 16" 1O'-7" 1O'-r 10.'-r 1OW" 17-7" 1D'-7" 25 0.024 16" 15'-10` 15'-10' 16-]0" 15'-10" 16'-10" 15'-10' 24" 1O'S low10'S' low 10'-5' 1D'-1" 24" 8'-1" B'-1" BLI" 8'-1' 8'-1" 8-1" 24` 11-4" 13'4" IT-4- 13-r 17-7 12-9' 72 0.042 15" 10'-1" 10'-1" 10'-1' I(-1' 10'-1" 9'-11" 0.032 16" 14'-4" 14'-4" 14'-4" 14'-4" 14'-0" 14'-0 0032 .032 16' 20'-2' 20'-2- 20-2" 220'-2-iFO77 20'-2" 24' V_r 91-V 9'-8" 9'-6" 9'-8' 9'-6" 24" 11-1" 11'-1" 11'-1" 11'-1" 11'-1" 11'-1" 24" 16'-7' 16-7' 16' 7' 16L7" 16'7" 16'-r 84 0.042 1f 9'-4" 94" 9'-4' 9'-4" 9'-4' 9'-4" 0 -�2 16" 1T-4" 1T-4" 17'-4" 1T-0" 1T-4" 1T-4" 0 '�2 16" 24-6" 24'-b" 24'-S' 24'-6" 24'3" 24'-6" 24" B'-11" 8'-111 8'-11, 8'-11" 8'-11" 8'-11" 24" 1V-3" 3 13'" 131-3" 13'3" 13,-3" 13'-3" 24" 20'-0" 2(-0' 20'-0" 204" 20'-0" 20'-0" NOTE: IT IS ACCEPTABLE TO SUBSTITUTE: (2) 3x8 @ 32"OC IN LIEU OF (1) 3x8 1610C (2) 3x8 C 48"OC IN LIEU OF (1) 3x6 Q 24"00 - (2) 2x6 @ 32"OC IN LIEU OF (1) 2K6 Q 16"OC -(2) 2x6 0 48"OC IN LIEU OF (1) 2x6 C 24"00 ALLOWABLE RAFTER SPANS 30 0.024 16" 9-9" 9-T 9'-9' 9.9' 9'-9" g-9" 30 0.024 16" 1.*W 14'-B' 14-8" 14L8" 14'-" 1W-W 24" T-b" T$ T-6" T-6' T5" 7-6" 24' 11'--2" 11'-2' I T--2" 11=2 11'-2" 11'-2' 0.032 16" 12'-6" 12'S" 12'-b" 12'S" 12'-6" 12.6" O.D32 16" 18-7" 1W-7" 18-7" 16-7" 18'r 18'7" 24" 10'-2° 10'-2" 10'-2" 10'-2" 1D'-2" 10'-2" 24" 15' 3" 1S-0" 151-3" 15'-3" 15'3" 15'3" 0.042 16" 16'-0' 16'-0" 16'-0" 16'-0" 16'-0" 16'-0" 0.042 16" 22-7" 22-7' 22'-7" 22-7" 2247 22'-7" 24' 12'-3" 12'-3" 12'3" 12'-3" 12'-3' 2_3 12'-3" 24" 18'- 18'-0" 18-6" 18'-6" 1B'-0" 18'-0" 40 0.024 16" 8'-0" 8'-0" 8'-0' 8'-0" 8'-0" 40 0.024 16' 12--10' 12-10" 12'-10" 12'-10" 12-10" 12-1D" 24" 6'-2" 6'-2" 6'-2" 6'-2" 6'-2" 6-2" 24" YAW 9'-1D' 9-10" W-117" 9'-10" T-10" 0.032 16" 10'-10" 10'-10" 10'-10' 19-10" 10'-1D" 10'-10" 0 .032 16" 16-,V 1&44 16'-4" 15-4" 16'4' IF-_4 24" 8'3" 8'-3" 8'-3" 8'-3° 8'-3" 8'-3" 24' 12'-0" 12-0" 12LV 1T-6" 17-W 12-6" 0.042 16' 13'-2' 13'-2" 13'-2" 13'-2" 13'-2" IT-2" . 0042 16" 19L9' W-r 19-9" 19'-9" w-9" 19'-9' 24" 10'-9" 101-F 1 U-91 10'-9" 10'-9" 10'-9" 24" 16'-r 1 G-r 16'-2" 16-2" '16'-2" 16'-2" 50 0.024 16" 7'-3" T-3" 7-3' T-3' 7'-3" 7-3" 50 . 0024 16" 10-10" 10'-10' 10'-1 D" 10'-10" 10'-10" 10'-10" 24" 6-2" 5'-2' S-2" 5'-2" 5'-2" 8-2" 24' 8'3' 8'3' 8'-3" 8'3" 8'-3" 8'-3" 0.032 16' 9'-9" 9'-T 9'-9" 9'-9' 91.9' 9-9" 0,032 16' 14-W 1*4r 14-8' 14-8" 14-W 14'-W 24" T-O' ' 7- T-0" T-0" T-O" T-O" 24" 11'r 111-Y 111-w 11L3' 11'3" 1113" 0.042 16' 11`--9" 11'-9" 11'-9" 11'-9" 11'-9" 11'-9" 0.042 16" 17-9" 1T-9' 1T-9' 1T-9' 17-9" 1T-9" 24' T-O" 9'-0" 9'-D" 9-0• 9'-0' 9'-0" 24" IV r 17-7" 13'-7" 13'-r 13'-7" 13'-7" 60 0.024 16" 5'-S" 5'-B' 5'-S" 5'r 5 7" 5,-s, 60 0.024 16" r-12" 7-12` T 12" T-11" T-11" T-8" 24" 6-6" 5'-6" 5'-6° 5'-5' 5'5" 6 4° 24. 7T9' 7-9' T-9" T-8' T-V 7-6' 0.032 16" 8'-9" 8'-9" 8=9" 8'-7" 8'-7" 8'-S" 0.032 16' 12-4 12-4' 12-4" 12-2' 12 T IT-10" 24" T-1" 7-1' 7-1" 6'-12" 6'-12' 6-10" 24" 10-1' 10'-1' 10-1" 9-11' 9'-12" T-8" 0.042 16" 10'-11" 10'-11' 10-11' 1O'S" 1OA0" 1O'S" O.D42 16" 14'-10" 14-10" 14-10' ILIL ]4'-10" 14L70" 24' 8'-11" 8-111 B'-11" 8'-10" 8'-10` 8'r 24' 12-8' 12-8' 12-W 12'-6" 125' 12-2" 72 0.024 16" 5'-2" 5-2" 5-2` 5L2` 5-2" 5 Z' 72 0.024 IV 6-11' 6'-11- 511' 6.-11• 6•-11" 6.-8n 2r 6-1' S-1' 5-1' 5'-1' 64' 4'-12" 24" 6'-11' G-11" &-I I' 6-11' 6-11' IT-9' 0.032 16" T-12' T-12" T-12' T-12" T-1-02 T-11" 0.032 16' I T-W I I-W 1 i'-3" 11-3' 1 T-7 114" 24" 6'-6" V-61 6'' U-61 6$" 651 24' 9'-3" T-3' 9-7 7-3." 9-3" 9-1" 0.042 16" 9'-12" 9"r 9'-Ir 9'-12" 9'-12' 9-11- 0.042 16" 13-11' 13'-11' 13'-11" 13'-11' 1T-11" 13L71' 24' 8'-2" 8'-2" 9L2" B'-2° TZ 8'-1' 24' 11'-r 1T-r 11-7" IlLr 11'7' 11'S" 84 0.024 16" 4-10' 4-10" 4-10" 4-10" 4'-10' 4-10" 84 0.024 16' S=12' & 12' 5--12' 6-17 6-12' 6-12" 24" 4'-B" 4-W 4-0" 4--B' 4'-B" 45" 24' -T-12' S'-12' 5-12" 5'-12" 5'-12" SLI2' D.032 16" T-5" T-5" 7L-5° T5' T5' T 5" 0.032 16' 10'-0' 10'_i" 10L6" 10'ii" 10'-0" 10'3° 24" 6'-1" 6'-1" 6' 1" 6'-1' 6-1" V-1" 24' 67 B' 7' 8'-7* 8'7" 8 T 8-7' 0.042 16" 9'-4" 1 9'-4- s-4° 9'-4' V-4- 9�" 0.042 17 13'-2! 13=r ]3-2" IT-2- 1T-2" IT-2" 24' T-7" T-r 7'-r 77 T 7" F-r 24' 10-9 1" 1 V 9" 10'-9" 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 F&9S roc S585 PF � OF cpo_k DATE SIGNED: July 8, 2019 05 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305,1420 �aP Mo ES TM EXPIRES ON: JUNE 30, 2020 REVISIONS MARK DATE - DESCRIPTION 4 STEL JOB # DA02-02 DATE 07108119 DRAWN BY RC CHECKED MOB IAPM0195 V 3.1.1 LATTICE STRUCTURES: ATTACHED COVERS RAFTER SPANS L3. 1 A NP -NOT PERMITTED - SITE SPECI FI C ENGINEERING REQUIRED. ROUNDUP TRI BUTARY WIDTH AS REQUIRED TO USE DESIGN TABLES. PROJECRON O.H. CLEAR SPAN rLTTRIBUTARY WIDTH TRIBUTARY=1/2 SPAN + O.H. NOTE: TRIBUTARY ON MULTIPLE SPANS IS EQUAL TO CENTER SPAN TO CENTER SPAN TRI BUTARY W I DTH TABLE (FT) OH CLEAR SPAN (FT) (FT) 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 0 3.0 3S 4.0 4.5 5.0 S.S 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 1 4.0 4.5 5.0 SS 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.6 10.0 10.5 11.0 11.5 12.0 NP NP 2 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.510.0 10.5 11.0 11.5 12.0 NP NP NP NP 3 6.0 65 7.0 7.5 6.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 NP NP NP NP NP NP 4 7.0 7.5 8.0 8.5 9.0 9.5 10.0 SOS 11.0 11.5 12.0 NP NP NP NP NP NP NP NP S 8.0 85 9.0 9.5 10.0 10.5 11.0 11.512.0 NP NP NP NP NP NP NP NP NP NP 2485 RAILROAD 5T, CORONA, CA 92880 951.736.4500 s5s5 DATE SIGNED: July 8, 2019 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 Ni o ES TM EXPIRES ON: JUNE 30, 2020 REVISIONS MARK DATE DESCRIPTION 4 STEL JOB # DA02-02 DATE 07108119 DRAWN BY RC CHECKED MDS IAPMO 195 V 3.1.1 LATTICE STRUCTURES: TRIBUTARY WIDTH TO BEAMS L1.5 3.000" 0 f l 2 x 3 LATTICE TUBE VIx47 ALUM, ALLOY 3004-1436 0.018' +7i 0 1.500' OR MOT �)L/2yLATTICE 11l2OR2x2 TUBE ALUM. ALLOY 3904-H36 l of l 3' x 8' RAFTER Ri r g f 2.000" 2' x 6 5' RAFTER R2 - ALUM. ALLOY 3004 H36 ALUM. ALLOY 3004-H36 FT 2.000" 6.000" 2.000� MAX R3 DBL 2' x 6.5' RAFTER 3xB RAFTER- FREESTANDING STRUCTURE 2X61/2 RAFTER -FREESTANDING STRUCTURE DBL. 2x6112RAFTER - FREESTANDING STRUCTURE LUGSL T N SPACING O/C WIND SPEED! EXP LUGSL T (IN) SPACING O!C WIND SPEED! LUGSL T ON) SPACING O/C WIND SPEED! EXP 110 B 110 C 1205 120 C 1305 1300 110 B 110 C 120 B 120 C 130 B 130 C 110 B 110 C 120 B 12001 130 B 1 130 C 10 0.042 16" 26'3" 26'-3" 26'-3" 26'-3" 26'-3" 25L7" 10 0.024 16" 14'-2° 14'-2" 14'-2" 14'-2" 14'-2" 13'-9" 10 0.D24 16" 1S=10" 19-10' 19-10" 19-10" 19'-10" 19'-4" 24' 21'-6" 21'-9' 21'-5" 21'-6" 21'-6" 21L0" 24" 11'-7" 11'-7" 11'-T' 11'-7" 11'-7% 11'-3" 24" 16'-3" 16'-3" 167-3" 15-3" 16'3" 15-10" 20 0.042 16" 21'-1 D" 21'-1 D." 21'-10' 21'-10" 21-10" 21'-10" 0.032 16" 18'-0" 1 B'-0" 1 B'-0" -0 18'" 18'-0" IT-7-16" 0. 032 25-3" 25'-3" 25-3" 25-Y 253' 24'-0" 24" 1 T-10" 1 T-10" 1T-10" 1 T-10" 17'-10" 1 T-10" 24" 14'-B" 14'-8" 14'-8" 14'-8" 14'-8" 14'-4" 24 20'-8" 20'-8" 20'-B" 20'-8' 20'-B" 20'-2" 25 0.042 16" 21'-0" 21'-S 21'-6" 21'-2" 21'-3" 20'-8" 0.042 16" 21'-9" 21'-9" 21'-9" 21'-9" 21'-S" 21'-2" 0.042 16" 30'-8" 30'-B" 30'-8" 30'-8' 30'-S" 29'-1 D" 24" 1T-T" 1T-T 17-7" 17' 4" 1T-6" 16'-10' 24" 17'-T IT-9- 17'-9" 1T-9" 1T-9" 1T-3" 24" 25'-1" 25-1" 25-1" 25'-1" 25'-1" 24-4- 30 30 0.042 16" 19--1" 19'-1" 19:1" 19--1" 19-1" 19'-1" 20 0.024 16" 11'-9" 11'-9" 11'-9" 11'-9" 11'-9" 1T' 9" 20 0.024 16" 16W" 16'7' 16-7" 16=T 16'-7" 16'-7" 24" 15 7" 15'-7" 15'-7" 15'-7" 15'-7" 15'-7" 24" 9-8" 9-8" 91-8' 9.8' 9'-8" 9-8" 24" 13'-7' 13=7" 13=7" 13=7" 13'-7- 13' 7" 40 0.042 16" 161-W 16'-8" 16'-8" 16'-" 16'-8" 16'-8" D.032 16" 15'-0" 1b'-0" 15-0" 15'-0" 15'-0" 15-7 0.032 16" 21'-1' 21'-1' 21'-1" 21'-1' 21'-1' 21'-1" 24" 13'-8" 1TAr 13'-8" 13'-8•' 13'-8" 13-g" 24" 1T-3" 12'-3" 12'3" 12'3" 1Z-3" 12'-3" �„ 17'-3" 1T-3" 17'-r 1T-3" 1T-3" - ITT so 0.042 15-0" 15'-G" 15-0' 15-0" 15'-0' 15-D" 0.042 16" 18L1" 78'-1" 18'-1" 18'-1" 18'-1" 18'-1" 0.042 16" 25'-0" 25-0" 25 6" 25 6 25f" 2Sb" 24" 11'-2" 11'-2" ll'-2' 11'-2" 11'-2" 11'-2" 24" 14'--9" 14'-9" 14'-9" 14'-9" 14'-9" 14'-9" 24" 20'-10" 20'-10" 20'-10" 20=10" 20'-10" 20'-10" 60 0.042 16" 18'-9" 18'-9" 18'-9' 1B'-B" 1B'-7" 18'-1" 25 0.024 16" 11LT' ll'-T" 11'-7" ll'-6i" 11'-6' 11'-2" 25 0.024 16" 16'-3" 1G-3' 16'-3" 16'-1" i6'2" 15'-S" 24" 15-0" 15'-0" 15'-4' 16-1" 15'-2" 14'-9" 24 9-0" 91-V 9'-6" 9'-F 9'�" 9-2" 24" 9 3" 9'3" 9'3" 9'3" 9-3' 9-3' 72 0.042 16" 1 T-2" 1 T-2' 1 T-2- 1 T2' 17'-2" i T-0" 0.032 16." 14'-9" 14'-9" 14'-9" 14'-0" 14'-7' 14'-2" 0.032 16" 20-9' 20'-9" 20-9" 20L6i" 20' 7" 19'-10" 24" 14'-T 14'-0' 14'-0' 14'-0' 14'-0" 13'-10' 24" 12'-l" 12'-l' 12'-1" 11'-10" 12'-0" 1l'-7" 24' lT-T 1T-0" IT-D" 16'-8" 15-9" 16'.3" 84 0.042 16" 16-11' 15'-11" 15'-11" 15-11" 15-1l' 15'-11' .0.042 16." 16." 1T-9" 17'-9' 17'-9" 17'-7" 17-8" 1T-1" 0.042 16" 25'-1' 25'-1' 25-1" 25-1" 25'-1" 26-1" 24" 13'-0" 13'-0' IT-O' 13'-0" 131-T 13.'-0' 14'-7' 14'-7" 14'-7" 14'-0" 14'-6" 14'-0" 24" 20'-6" 20'-6' 20'-6" 20'-6" 20'-6" 20'-6" NOTE: IT IS ACCEPTABLE TO SUBSTITUTE: (2) 3x8 (� 32"OC IN LIEU OF (1) 3x8 16"OC (2) 3x8 481100 IN UEU OF (1) 3x8 24"OC EU OF (1) 2x6 (d1 16"OC (2) 2x6 @ 32"OC IN LIEU - (2) 2x6 @ 48.00 IN LIEU OF (1) 2x6 24.00 )_ALLOWABLE RAFTER SPANS 30 0.024 16, 10'-3" 10'-3" 10'3" 10'3' 10'-3" 10'-3" 30 0.024 16" 14'-6" 14'-6" 14-6" 14W 14'$" 14'-6" 24" 8'-0" 8'-G' 9-6" 8'•6' 6-6" 9-6" 24' llL10" 11'-10" 11'-10" 11L10" 11'-10" ll'-10" 0.032 16" 13'-l" 13'-1" 1T-1" 13'-l" 13'-1' 'IT-1" 1 0.032 16" 18'4" 18'-4" 18'-4' 1B-4" 18'-4" 18'-4" 24" 10'-8"- 10'A -0" 10'" 101-8" 10'-8" 10'-8" 24' 15-1" 15'-1" 16-1" 15-1" 15-1' 16-1- 0.042 16." 15'-9" 15'-9" 15-9" 15'-9" 15'-9" 16-9" O.D42 16' 22'-2" 2Z-2" 22'-2" 22-2" 22'2" 27-2" 24' 12'-10" 12•-10" 12'-10" 12'-10" 12'-10" 12'-10" 24" 18'-2" 18'-2' 18-2" 1BL2" 18L2" 18'-2" 40 0.024 16" 9-1' 9.1" 9.1" 9'-1" 9'-1" 9-1" 40 0.024 16" 12'-8' 12'-6' 12-8" 12-8- 12'3" 1Z-w " 7L2" TZ T-2" T-2' T-7 7'-2" 24" 10'-4" 10'4" 10'4' 10'-4" 194' 10'-4" 0.032 16" 111-6" 11'-51' -0 11'" -0 11'" 11'-6" 11'-0 0.032 16" 19-1" 16'-1" 16'-1" 16L1" 16'-1" 16'-1" 24" 9'4" 9�" 9'-4' 9'-4" 9'-4" g-4" 24' 13-2" 13L2' 13-2' 13-2" 13-2" 13`-2" 0.042 16" 13LS" 13'-9" 13'-9" 1 T V 13'-9" 13'-9' 0.042 16" 19-4' 19'-4" 19-4' 19-4' 19' 4" 174' 24" 11-3" 11'3" 11'3" 113" 1 T-3" 11'-3" 24" 15'-10" 15'-10" 15'-10' 15'-10' 15'-1 D" 15-10' 50 0.024 16" 8'-7 8'-2" 8'-2' 6.2" 8'-Z' V-Z' 50 0.024 16" 11'4" 114" 11-' 11-4" 11'4" 11'4" 24" 5'-9' S-7' S-9" 5-7 5-9' 6-9" 24" 9'-4° 9'_" 74" 9'_" 9'4" 9-4" 16" IDLY 10'3" 10'-3" 10'3" 10'-3" 10'-3" 0.032 16" 14'-6" 14'-6" 14'-6" 14L6" 14'-6" 14'-0" F() 24" 8'-4" 8'-4" 8'-4' B'-4" 8'-4" 9-4" 24" 11'-10' 11'-10" 111-10' 11'-10" 11'-10" 11'-10" 16" 17--6" 1Z-6" 12'6" 12'-6" 12'6" 12'-6" 0.042 16" 1T-6' 17"-V 17-6" 1T-6" 1T$" IT-F 24' 10'-2" 10L2" 10'-2" 10'-2" 10'-2' 10'-2" 24" 14'-3" 14'-3" 14-3" 14-3" 14'3" 14'3" 60 0.024V24" 16" 5-6" 5'-B' 5-B" 5'-7" 5'-7" 5-0" 60 0.024 16" 7-12" T-13'° T-12" T-11" 7-11' T-8" 51-6" 5-G' S-6" 5.5" 51-V 5-4' 24" T-9" T-9' T-9" Tor T-8" T-G' D.032T-l' 8'-9' 8'-9' B-9" ENP B'-T" 9-5" 0.032 16" 12'-4' 12'-M1 12-4" 12-2" 12L2" 11-10" T-1" T-1" 6'-12" 6'-IT 6'-10" 24" 10'-1' 10L1' 10'-l' 9'-1l' 5-12" 9'-B" 0.04210'-11" 10'-11" l0'-11" 10'-9" 10'-10" 10'-6" 0.042 16" 14'-10" 14L10' 14'-10" 14'-10" 14-10" 14'-10" 8'-11" 8'-11` 8'-11' 8'-10" 8'-1A' 8-T' 24' 12'-W 12'-8" 1T-8" IT-6" 1Z-V 12'-2" 72 0.0245'-2" 5-2" 5'-2" 5'-2" 5'2' S-2" 72 0.024 16" 5-11" 6-11' 6-11- 6'-11` 6'-11" G-9" 24" 5'-1" 5'-l" 5'-1" 5'-1' S-1" 4'-12" 24' 6-11' 6'-11' 5-11" 6'-11' &-11' 6'-9" 0.032 16" T-12" T-12' T-12" T-12" T-12' T-11" 0.032 16" 11'-3" 11'-3' 1l'-0" 11'„'" 11'3" 11L2" 24' 6'-0' 6'-6" "" 6'-0' 6'-0" SLY 24" 9'-3' 9-3' 9-3" V-3" 9-3' 9L1" 0.042 16" T--12" 9'-12" 9-12" S'-12" 9'-lT 9'-11' 0.042 16" 13'-11" 13-11" 13-11' 13'-11" 13'-11" 13'-11" 24" 8'-2" 8'-2" 8-2" B' 2" 8'-2" 8'-1" 24" 1 Y-T 11' T 11-7' 11-7" 1 l'7' 1 V-6' 84 0.024 16" 4'-10" 4'-10' 4'-1 D" 4'-10'k 4'-10' 4'-10" 84 0.024 16" 5'-12' 6-12" 5-12' 6-12' 5'-12" 5-12' 24" 4'-8' 4'-8" 4-8" 4'3" 4'3•' 4'-8" 24" 5'-12' 5'-12' 6L72' 5'-12" 5-12" 5'-12" 0.032 i6" 7-5" 7•5" T-5" 7-5' T-5" T-Y 0.032 16" 10'-0" 1&-v 10LW 1A'-6" 10'fi" 10'-0" 24" 6'-1" 6'-1" 6'-1" 6'-1' 6=1" V-1" 24' 8'-7" 8'7• 8'-7" 8'-7" ST B--r D.o42 16" 9'4" 9' 4" 9-4` 9'-4' 9-4" 9'-V 0.042 16' 13'-T 1T-2' 13-Y 13L2' 1T-2" 13-2" 24" T-7" 7'-7" 7'-7" T-7' T7" 7'--r 24' 10'-9" 10'-9" 10'-9" 10.9' 10'-9" 10-5" ALUM. ALLOY 6063 -TBJ ALUM. ALLOY 3004 H36 ALUM. ALLOY 3004-H36 JAWM. ALLOY 3DO4-H36 STEEL ASTM A653-SS GRADE 50 G60 1.229" 2.i38' 0.065" 2.010" TYP• p2.9p0�8" tqd _ 12 GA. . CONTINUOUS STEEL INSERT 0.042 Is" p o N omc6 N CO r 0.042' _ .TYP. -- - -- _ - - .a N u7 O 2.824" L3.000" NOTE: 3.000" SEE 1/S4.6 FOR DETAILS AT FAN BEAM. FAN BEAM 3 x 8 x 0,042' ALUM. BEAM WI- B5 811 3 x 8 x 0A42 3 x 3 x A032' ALUM. BEAM W/- B1T s"=r o" B14 12 GA STL INSERT 3' =1'-0" 3°=1'-0° 12 GA STL 'U' CHANNEL 0.9845" ALUM. ALLOY 3004-H36 ALUM. ALLOY 3004-H36 W.UM. ALLOY 3004-H36 ALUM. ALLOY 3004-H36 R� STEEL ASTM A653-SS GRADE 5o G80 ISTEEL ASTM A653 SS GRADE 50 G60 gyp. ALUMINUM BEAM & CONTINUOUS STEEL INSERT PER B14/54.2 0.042" o TYP. TYP. 0 0 0,042' o 0 o Typ• q o r- a0 co o ano ao r j ' 2.000" 4.000" 2.000" 7898- 3.000" 4.Oo0" 3.000" b 3.000' 4.000` F �3.00T MAX MAX. MAX 3 x 8 x OA42' w/ �3x.042' ALUM. BEAM B12 DBL 3 x 8 x 0.042E39 DBL 2 x 61/2 x 0.042' 12 GA. STL V CHANNEL 6'=1'-0" B15 INSERT 3"=1'-o° 3"=1' 0" ALUM. ALL 3004-H36 ALUM, ALLOY 3004-H35 ALUM. ALLOY 3004-H36 ALll�F. ALLOY 3004 H36 STEEL ASTM A653 SS GRADE 50 G60 S 0- ASTM A653-SS GRADE 50 G60 1 229• STEEL ASTM A653-SS GRADE 50 G60 ALUMINUM BEAM ALUMINUM BEAM & CONTINUOUS & CONTINUOUS STEEL INSERT c 14 GA. STEEL INSERT PER B14/S4.2 CONTINUOUS PER B18/S4.2 TYP. STEEL INSERT TYP' 0.032" o 0 0 o r- o o ^ 0.042" °0 TYP or O 2.000" 4.000" "2000' L 2.824" 1ApJ1 3.000. 4.000" 3.000" 3.000° 4.000" 3.000" W MAX, 3.000' B19 DBL 3 x 8 x 0.042' w/ DBL 3 x 8 x 0.042' ALUM BEAM Q42' ALUM. BEAM W/- B14 DBL 2 x 81/2 x 0032' 12 QA STL "U' CHARNEL 3°=1'-0" B18 W/ 12 GA STL INSERT 3"-i'-o" ��14XGMSTL INSERT 3"=1' -0° 11 ASTM A500 GRADE JASTM A500 GRADE B JALUK ALLOY 300TH36 ALUM. ALLOY 3004-436 3" ALUMINUM OR STEEL POST PER PLAN N Of O 0.032" 0.188" o c 0.188" ccc NO, 0 iu 0.042' 3.000" 3.000" 4.000' 2.000" 3.000" N�1 2.000" IT IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) WITH IT IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) BY ALUMINUM BENT PLATES FOR AESTHETICAL PURPOSES. NO FASTENERS SECTION Cl FOR AESTHETICAL PURPOSES. NO FASTENERS ARE REQUIRED. NOTE: ARE REQUIRED. SLEEVE SHALL EXTEND FROM THE FOUNDATION TO THE SLEEVE SHALL EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF SEE TABLE 1 ON L1.x FOR APPLICATION OF THIS DETAIL UNDERSIDE OF THE BEAM/COLUMN CONNECTION. THE BEAM/COLUMN CONNECTION. C70 HSS 4 x 4 x 3118 C7 HSS 3 x 3 x 3/16 SPb D.a42' SIDE PLATES Cl 3' SQ. ALUM. POST ASTM A500 GRADE B ASfM A500 GRADE-171 ALUM. ALLOY 6063-T6 ALUM. ALLOY 3004-H35 0.762' a I .50T j a F1 I 0.04E CD o 0.400' 0.250" 0 0.250" 0 0 0. o oTfP _ kRO.T25 M ri :46� TYP- M 3.000" 3.OD0" I 3.00D" 0 4.000" Nam: NO NOTE: IT IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) WITH IT IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) BY IT IS AOCEPTARLF TO COVER THIS COLUMN SECTION (FULL HEIGHT) BY TT IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) BY ALUMINUM BEM PLATES FOR AESTHETICAL PURPOSES, NO FASTENERS SECTION Cl FOR AESTHETICAL PURPOSES. NO FASTENERS ARE REQUIRED. SECTION Cl FOR AESTHEnCA,L PURPOSES. NO FASTENERS ARE REQUIRED. SECTION CI FOR AESTMErM PURPOSES. NO FASTENERS ARE REQUIRED. ARE REQUIRED. SLEEVE SHALL EXTEND FROM THE FOUNDATION TO THE SLEEVE SHALL EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF SLEEVE SHALL EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF SLEEVE SHALL EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF UNDERSIDE OF THE BEAM/COLUMN CONNECTION. THE BEAM/COLUMN CONNECTION. THE BEAM/COLUMN CONNECTION. THE BEAM/COLUMN CONNECTION. �� HSS 4 x 4 x 1/4 GS HSS 3 x 3 x 114 C5 3' MAG POST C2 3" SQ" ALUM. POST ASTM A.SDO GRADE B STEEL A653 GRADE 50 CP60 ALUM. ALLOY 3004-H36 3' ALUMINUM OR STEEL POST PER PLAN 1.500" �o c 0.048 0 0.400" 0 0 C. CD 0.313'q000 o - R0.124E� TYP.O 3,ODD" o 0.032" 2.000' 3.000" 2.000" NOTE: ! IT IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) BY IT IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) BY SECTION Cl FOR AESTHETICAL PURPOSES. NO FASTENERS ARE REQUIRED. SECTION Cl FOR AESTHETICAL PURPOSES. NO FASTENERS ARE REQUIRED. NS 1LE: SLEEVE SHALL EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF SLEEVE SHALL EXTEND FROM THE FOUNDATION, TO THE UNDERSIDE OF SEE TABLE 1 ON L1.x FOR APPLICATION OF THIS DETAIL THE BEAM/COLUMN CONNECTION. THE BEAM/COLUMN CONNECTION. 09 HSS 3 x 3 x 6I1S CS 3' SQ STEEL POST SP3 OA3T SIDE PLATES 3'=1 W ALUM. ALLOT 5063-T6 2.875" g 0.067" N U NOTE: BRACKET IS 2%° LONG 4 V BRACKET AT COLUMN 025n- STEEL ASTM A36 c a ROOF BRACKET S LISx8x1/4x7 STEEL ASTM A3fi SNO_W BRACKET L12 x 8 x 1/2 x 2' 2"=1'-O" ALUM. ALLOY 6063-T6 'H" BRACKET ALUM. ALLOY 60637T6 I 6.065" o0 TYP. u? 1 2.275" ` LENGTH = 2Y" @ SINGLE 3 x 8 OR 3 x 3 BEAM BELOW LENGTH = 6-" @ DOUBLE 2 x 6V2 BEAM BELOW LENGTH= 8Y4" @ DOUBLE 3 x 8 BEAM BELOW Cj)= CKET:r RAPPER TO BEAM 6"=V-o- ALUM. ALLOY 60046 in m m `— LENGTH= 2Y' @ SINGLE 3 x 8 OR 3 x 3 BEAM BELOW LENGTH= 6%" @ DOUBLE 2 x 6Y2" BEAM BELOW LENGTH= 8"-" @ DOUBLE 3 x 8 BEAM BELOW (�)-= CKETAFTER TO BEAM 6"=1' 0° 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 ���1 LESS IN 'Rom �y�Q qTE OF CA��F� DATE SIGNED: July 8, 2019 C�'AeW7TC� 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305,11501 FAX 949.305.1420 SAP M0 ES TM EXPIRES ON: JUNE 30, 2020 REVISIONS MARK I DATE DESCRIPTION 4STELJOB # DA02-02 DATE 07108118 DRAWN BY RC CHECKED MDS IAPM0 195 V 3.1.1 LATTICE STRUCTURES: CONNECTORS L4.3 HANGER CHANNEL FAN BEAM (19'-0" MAX. SPAN) FAN SUPPORT. BEAM/HEADER SEE DETAIL 2/- CEILING FAN AND/ r�r OR LIGHT FIXTURE �xr (MAX. 50 LB) rr �r •� a I I, IIII CROSS SECTION AT FAN BEAM 3/16'=1'-0" 2'-0" MAX. FAN BEAM, 2 x 61'2 OR 3 x 8, WOOD FILLED 6" LONG 'U' BRACKET PER 2/1-4.3 I I OR 3/L4.3 TYP EA END, EA BLOCKING (4) #14 x 1Y2° SMS TO RAFTER (2) #14 x 1Y" SMS TO 8LKG, T&B a (E) RAFTER W/ WOOD FILL, EA SIDE OF FAN BEAM TYP I I ATTACH FAN TO FAN BEAM PER MANUFACTURER'S RECOMMENDATIONS, MIN (2) #14 x %Y SMS MAX WEIGHT OF FAN IS 50 LB. 50# MAX FAN SUPPORT 3/4'=1'-O" 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 �FES3 I�C S 5885 r RCICjUr' \Q' 9TF OF CpO' DATE SIGNED: July 8, 2019 ®�cTCL� 4�! VF:c'ilr�-,•`.i time •'7'r 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 �Ap mo ES TM EXPIRES ON: JUNE 30, 2020 REVISIONS MARK DATE DESCRIPTION 4 STEL JOB # DA02-02 DATE 07108119 DRAWN BY RC CHECKED MDS IAPM0 195 V 3.1.1 LATTICE STRUCTURES: FAN BEAM DETAILS L4.4 TABLE 1 -MAXIMUM CLR SPAN TO ADJACENT BEAM WHEN USING DETAIL 4/1-6.2 LL/GSL EXISfINGFRAMINGMEMBER (PSF) AT ROOF OVERHANG BRACKETOFFSET"D" 24" 18" 12" 6" 2x4 FULL 12' 10" 19' 11" 28' 0" 2x6 NOTCHED 20' 6" 28' 0" 25 0" 28' 0" 28' 0" 10 2x6 FULL OR 2x8 NOTCHED 2x8 FULL OR 2xlO NOTCHED 28' 0" 28' 0'-' 28' 0" .29 0"- ..29.W 28' 0" 28' 0" 1V-0''. -- 2x4 FULL 7 9" 11' 10" 19' 5" 28' 0" 2x6 NOTCHED 12' 3" 171W 25 0" 28' 0" 20 2x6 FULL OR 2x8 NOTCHED 19' 7" 277" 28' 0" 28' 0" 2x8 FULLOR 2x10 NOTCHED 28' 0" 28' 0" 28.0.. 28, a' 2x4 FULL T 4" ITT' 18' 7" 28' 0" 2x6 NOTCHED 11' 8" 170" 27' 1" 28' 0" 25 2x6 FULL OR 2x8 NOTCHED 18' 8" 26' 4" 28' 0" 28' 0" 2x8 FULL OR 2x10 NOTCHED 28' 0" 28' 0" 28' 0" 28' 0" 2x4 FULL 5' 11" 9' 4" 15' 8" 28' 0" 2x6 NOTCHED 9' 6" 14' 2" 22' 11" 28' 0" 30 2x6 FULL OR 2x6 NOTCHED 15'5" 22' 0" 28' 0" 28' 0" 2x8 FULLOR 2x10 NOTCHED 26' 3" 28' 0" 28' 0" 28' 0" 2x4 FULL 4' 8" 7' 7" 12' 11" 278" 2x6 NOTCHED 7' 9" 11' 8" 19' 0" 28' 0" 36 2x6 FULL OR 2x8 NOTCHED 12' 9" 18' 4" 28' 0" 28' 0" 2x8 FULL OR 2x10 NOTCHED 21' 10" 18' 6" 28' 0" 28' 0" 2x4 FULL 4' W 6' 9" 12' 0" 25' 2" 2x6 NOTCHED 6' 9" 10' 5" 176" 28' 0" 40 2x6 FULL OR 2x8 NOTCHED 11' 4" 16' 6" 26' 7" 28' 0" 2x8 FULL OR 2x10 NOTCHED 19' T' 27' 6" 28' 0" 28' 0" 2x4 FULL 2x6 NOTCHED 39" 65" 6' 4" 9' 11" 11' 0" 16' 4" 23' 10" 28' 0" 42 2x6 FULL OR 2x8 NOTCHED 10' 9" 15' 8" 24' 11" 28' D" 2x8 FULL OR 2x10 NOTCHED 10 7" 15' 10" 25' 2" 28' 0" 2x4 FULL 2' 10" 5' 2" 9' 8" 20' 4" 2x6 NOTCHED 5' 1" 8' 2" 14' 2" 28' 0" 50 2x6 FULL OR 2x8 NOTCHED 8' 9" 13' 0" 21' 6" 28' 0" 2x8 FULL OR 2x10 NOTCHED 15, 6" 21' 11" 28' 0" 28' 0" 2x4 FULL ZV 4'1" T6" 16'10" 2x6 NOTCHED 3' 11" 6' 7" 11' 4" 16' 11" 60 2x6 FULL OR 2x8 NOTCHED 2x8 FULL OR 2x10 NOTCHED T 0" 12' 8" 10' 8" 15 9" 10' 10" 15 9" 16' 11" 16' 11" 2x4 FULL 1-9- 3' 2" I V 2" 7 G' 2x6 NOTCHED 3 0" 5' 3" G 5' T 6" 72 2x6 FULL OR 2x8 NOTCHED 4' 3" 5' 4" 6S" 76" 2x8 FULL OR 2x10 NOTCHED 4 3" 5' 4" 5 5" 76" 2x4 FULL NG NG NG 17 9" 2x6 NOTCHED NG NG NG 0' 9" 84 2x6 FULL OR 2x8 NOTCHED NG NG NG 0' 9" 2x8 FULL OR2x10 NOTCHED NG NG NG 0' 9" NOTES: 1- FOR 10 PSF LL/GSL, USE ROOF BRACKET5/S4.5. 2- FOR LL/GSL>_ 20 PSF, USE SNOW BRACKET6/S4.5. 3 - ASSUMPTIONS: - NOTCH CAN BE UP TO 1" IN 2x6, UP TO 1.5" IN 2x8 OR 2XIO. 40FTMAX (E) ROOF RAFTER/JOIST/TRUSS BACKSPAN. MAX (E) ROOF RAFTER / JOIST/ TRUSS SPACING TO BE 24"OC. TABLE 1A - MAXIMUM CLR SPAN TABLE 1 B -MAXIMUM CLR SPAN TO ADJACENT BEAM TO ADJACENT BEAM WHEN USING ROOF BRACKET WHEN USING SNOW BRACKET PER 5/1-4.3 AND 4C/L6.2 PER 6/1-4.3 AND 4D7L6.2 LL/GSL (PSF) WIND SPEED & EXPOSURE I_L/GSL (PSF) WIND SPEED & EXPOSURE 110B 120B 110C 130B 120C 130C 110B,110C 120B,130B 120C 130C 10— -17'-0" 1 15'.-0" 14'•0" 12'-0" 10 24-'-01-1 2X:0" ...2f4 _ 20 20'-0" 19'-9" 18'-3" 25 19'-3" 19'-3" 17-9" NOTES: 1- WHEN USING ROOF BRACKET PER 30 1G-3" 16-3" 16-3" 4C/L6.2, THE MAXIMUM PROJECTION 36 1'-9" 3 13' -9 13'-9" SHALL BETHESMALLESTPROJECTION FROM TABLE 1 AN D TABLE IA. 2- WHEN USING SNOW BRACKET PER 4D/L6.2, TH E MAX I MU M P ROJ ECTI 0 N SHALL BETHESMALLESTPROJECTI0N 40 12'_3" 12'-3" 12'-9 42 IV-9" IV-9" 11'-9" 50 10'-0" IT-0" 19-0" 60 8'-3" 8'-3" 8'-3" 72 7-0" T-Y' T-0 FROMTABLE I ANDTABLE IB. 84 6'-0 6'-0" 6'-0" TABLE 2 - NUMBER OF SIMPSON A34s AND A35s REQUIRED BETWEEN FASCIA AND ROOF SHEATHING PER 4A/L6.2 WHEN CONNECTING PATIO COVER TO EXISTING ROOF OVERHANG TRIB 10 PSF 20 PSF 25 PSF 30 PSF 36 PSF 40 PSF 1 42 PSF 50 PSF 60 PSF 72 PSF 84 PSF WIDTH LL/GSL LL/GSL GSL GSL GSL GSL GSL GSL GSL GSL GSL 5' 1 1 1 1 1 1 1 1 2 2 2 6' 1 1 1 1 1 1 1 2 2 2 2 T 1 1 1 1 1 1 2 2 2 2 2 8' 1 1 1 1 1 2 2 2 2 2 2 9' 1 1 1 1 2 2 2 2 2 2 2 10' 1 1 1 2 2 2 2 2 2 2 2 11' 1 1 2 2 2 2 2 2 2 2 NG 12' 1 1 2 2 2 2 2 2 2 NG NG .A NUMBER 1 IN THIS TABLE MEANS THAT (1)A34+ (1)A35 ARE REQ'D. A NUMBER 2 IN THIS TABLE MEANS THAT (2)A34s + (2)A35s ARE REQ'D. (STAGGER CONNECTORS WHEN USING (2) IN SAME WOOD MEMBER) A34s: USE (8) SIMPSON SD9112SCREWS TO CONNECT A34S TO (E) FASCIA AND ROOF FRAMING A35s: USE (6) SPAX # 6 x 1/2" SCREWS TO CONN ECTA35S TO (E) ROOF SHEATHING USE (6) SPAX#6x 1/2" ORSIMPSON SD9112 SCREWS TO CONNECT A35S TO (E) ROOF FRAMING TABLE 3A - FASTENERS REQUIRED AT CONNECTION OF RAFTER BRACKETS PER DETAIL2/1-6.2 TO EXISTING WOOD STUD WALL FRAMING @16"OC TRIB WIDTH 10 PSF LL/GSL 20 PSF LL/GSL 25 PSFL30PSF GSL 36PSF GSL 40PSF GSL 42PSF GSL 50 PSF GSL 60 PSF GSL 72 PSF GSL 84 PSF GSL 5' (2) A (2) A (2) A (3) A (3) A (3) A (3) A (3) A (3) A (3) A 6 (2) A (2) A (2) A (3) A (3) A (3) A (3) A (3) A (3) B (3) B 7' (2) A (2) A (2) A (3) A (3) A (3) A 1 (3) A (3) A (3) B (3) C 8' A (3) A (3) A (3) A (3) A (3) A (3) B (3) C (3) C 9' 2) A (3) A (3) A (3) A (3) A (3) B (3) C (3) C (3) C 10' t(2)At(2)A2) 2) A (3) A (3) A (3) A (3) B (3) C (3) C 3C11' 2) B (3) A (3) A (3) B (3) B 4C(13) C (3) C12' �(3) 2) B (3) A (3) B (3) B (3) B 3) C (3) C A- 1/4" LAG SCREWS W/ 21/Z' PENETRATION IN MIN 2x WALLSTUDS @ 16"OC MAX B- 5/16" LAG SCREWS W/ 21/2' PENETRATION IN MIN 2x WALLSTUDS @ 16"OC MAX C- 7/16" LAG SCREWS W/ 3Y2' PENETRATION IN MIN 2x WALLSTUDS @ 16110C MAX D- 1/2" LAG SCREWS W/ 4" PENETRATION IN MIN 2x WALL STUDS @ 16110C MAX TABLE 3D @ 16"OC - FASTENERS REQUIRED AT CONNECTION OF RAFTER BRACKETS PER DETAIL2/L6.2 TO EXISTING WOOD -FILLED 3xALUMINUM LEDGER TRIB 10 PSF 20 PSF 25 PSF 30 PSF 36 PSF 40 PSF 42 PSF I 50 PSF I W PSF 72 PSF 84 PSF WIDTH LL/GSLLL/GSL GSL GSL GSL GSL GSL GSL GSL I GSL GSL 5 A-16"oc A-16"oc A-16"oc A-16"oc A-16"oc A-16"oc A-16"oc A-16"oc A-16"oc 1-16"oc C-16"oc 6' A-16"oc A-16"oc A-16"oc A-16"oc A-16"oc A-16"oc A-16"oc A-16"oc B-16"Dc C-16"oc D-16"oc T A-16"oc A-16"oc A-16"oc A-16"oc A-16"oc A-16"oc A-16"oc B-IV"oc C-16"oc D-16"oc IN 9 A-16"oc A-16"oc A-16"Dc A-16"oc A-16"oc B-16"oc B-16'oc C-16'oc D-16"oc NG NG 9' A-16"oc A-16"oc A-16"oc A-16"oc B-16"oc C-16"oc C-16"oc C-16"oc NG NG NG 10' A-16"oc A-16"oc A-16"oc B-16"oc C-16"oc C-16"oc C-16"oc D-16"oc NG NG NG 11' A-16"oc A-16"oc A-16"oc B-16"oc C-16"oc C-16"oc D-16"oc NG NG NG NG 12' A-16"oc I A-16"oc I B-16"oc I C-16"oc C-16"oc D-16"oc I NG NG NG NG I NG A - 1/4" LAG SCREWS B - 5/16" LAG SCREWS C- 7/16" LAG SCREWS D -1/2" LAG SCREWS ALL FASTENERS TO HAVE 3" PENETRATION INTO THE WOOD -FILLED 3xALUMINUM LEDGER USE (3) FASTENERS FROM THE RAFTER BRACKET TO THE WOOD -FILLED 3x ALUMINUM LEDGER TABLE 3D @ 24"OC - FASTENERS REQUIRED AT CONNECTION OF RAFTER BRACKETS PERDETAIL2/L6.2 TO EXISTING WOOD -FILLED 3xALUMINUM LEDGER TRIB 10 PSF 20 PSF 25 PSF 30 PSF 36 PSF 40 PSF 42 PSF 50 PSF 60 PSF 72 PSF 84 PSF WIDTH LL/GSL LL/GSL GSL GSL GSL GSL GSL GSL 1 GSL GSL GSL 5' A-24"oc A-24"oc A-24"oc A-24"oc A-24"oc A-24"oc B-24"oc C-24"oc C-24"oc NG NG 0 A-24"oc A-24"oc A-24"oc A-24"oc B-24"oc C-24"oc C-24"oc C-24"oc NG NG NG 7 A-24"oc A-24"oc A-24"oc B-24"oc C-24"oc C-24'oc C-24"oc NG NG NG NG 8' A-24"oc A-24"oc B-24"oc C-24"oc C-24"oc D-24"oc NG NG NG NG NG 9' A-24"oc B-24"oc B-24"oc C-24"oc D-24"oc NG NG NG NG NG NG 10, A-24"oc C-24"oc C-24"oc D-24"oc NG NG NG NG NG NG NG 11' A-24"oc C-24"oc C-24"oc NG NG NG NG NG NG NG NG 12' A-24"oc C-24"oc D-24"oc NG NG I NG I NGI NG NG NG NG A - 1/4" LAG SCREWS B - 5/1W LAG SCREWS C- 7/16" LAG SCREWS D-1/Y' LAG SCREWS ALL FASTEN ERS TO HAV E 3" P EN ETRATION INTO THE WOOD -FILLED 3x ALUMIN UM LEDGER USE (3) FASTEN ERS FROM THE RAFTER BRACKET TO THE WOOD -FILLED 3x ALUMINUM LEDGER TABLE 4 - ANCHORS INSTALLED INTO THE SIDE OF 6 IN THICK MIN CONCRETE OR CMU WALLS LUGSL = 84 PSF MAX IN CONCRETE, USE (2) ROWS OF 1/2" DIA SIMPSON STRONG-BOLT2 @ 32"OC, STAINLESS STEEL, WITH 3" MIN EMBED, STAGGERED, INSTALLED P ER I CC- ES R-3037. I N CMU, USE (2) ROWS OF 1/2" DIA SIMPSON WEDGE -ALL @ 32" OC, STAINLESS STEEL, WITH 3 31W MIN EMBED, STAGGERED, INSTALLED PER ICC ESR-1396. USE 3" SQ.x1/4" STAINLESS STEEL WASHER WHEN INSTAWNG NEW WOOD LEDGER AGAINST EXISTING CONCRETE WALL ALLOWA9E CLEAR DIMENSION TO BEAM SEE TABLE 1B ON L6.1 LH RACKLT AND ATTACHMENT PER 2AU 3 x 8 WOOD FILLED 3 x 9' FILLED ST WOOD FILLED ALUMINUM RAFTER ALUMINUM LEDGER ALUMINALUMINUM LEDGER DECK/ (3) V-0 FU L-THREADED E ROOF B1600 WHENERE OCCURS DIREC LAO SCREWS W/- 4 PER 6AL4.3 PENETRATION IMO (E) CONT. TIP ��OR(),JE ff�PDm SpTEWS w / 2)i- 41\ o 0 0 oCOLW PENETRATION < ¢ a BEAM _ J BEAM 21 WAX HOiE COLUI �-- (E) BLOCKING BETWEEN OCNT. RAFTERS OR TRUSSES, I(E)pCONT. TRUSS wOCCURS CHORDOR ((EWHEREWALL SEEERS @ 24" OC IRE ABOVE RAFTER OR TRUSS BAC KSPAN ORES: 6-0" MN 40-0" MAX 1. EESIING ROOF DESIGN :LOAM RDL = 3 PSF (MN) TO 8 PSF (MAX) 2 NEW PAT10 DESIGN ILDA LL = 50 PSIF MAX 3. PLACE "SIKA FLEX' OR SIMILAR MATERIAL BETWEEN EFACKET AND COMPOSITE SHINGLE ROOFING TO PROVIDE SEAL 4. BRACKET M.0 BE ORIENTATED TiW IM ROOF EDGE AS SHOWNN. 5. USE THIS DETAL WITH ROOF BRACKET PER 6/L4.3 AND TARES 1 AND 1B ON L6.1. 6. VERTICAL LEG OF BRACIET sHu BE LOCATED Z MIX. FROM FACE OF WAIN„ ON EITHER SIDE OF WALL D CONNECTION TIO TOP OF EICNSDNG ROOF MOP ALLOWABLE AFAR DIMENSION TO BEAM DN- ROOF BrZACKL7 PER 5A4.3 SEE TABLE 1A ON L6.1 SEE TABLE 1 2 x 6V" OR 3 x 8 WOOD ON L6.1 (3) VO FLU -THREADED FILLED ALUMINUM LEDGER LPG SCREWS W/- 1%" _ PENETRATION (� XZ�WS ATTACHMENT PER 2AS.2 I W/THF4ADED � PENERAIION ALUMINUM R* <<R PLIERHWTNE ROOF BRACIKLT L J M1K- ORIENTATION " MIN. A� RAFTER TO LEDGER CONNECTION �r- ISM - QENNG CAPA= OF THE DIS ham, BJI DW, M• 1. WHEN CONNECTING TO AN EASIING BUILDING WALL WITHOUT OPENINGS, SITE -SPECIFIC ENGINEERING IS REQUIRED TO VERIFY ADMUALY OF THE EXISTING STUD WALL FRAMING WHEN THE PATIO COVER PROJECTION IS WIDER THAN THE MAX POOIECDON SHOWN IN THE FOLLOWING TARE 2 WHEN CONNECTING TO AN EXISTING BUILDING WHERE AN OPENING IS PRESENT UNDER THE ATTAC M NT OF THE PATIO TO THE LAVE OR THE WALL, SITE -SPECIFIC ENGINEERING IS REQUIRED TO VERIFY ADEQUACY OF THE EXMNG STUD WALL FRAMING (INCLUDING HEADER SIZE) WHEN THE PAT10 COVER PROJECTION IS WIDER THAN THE MAX PROECTION SHOWN IN THE FOLLOWING TARE OR WHEN THE EXISTING OPENING IS WIDER THAN THE MAX OPENING WIDTH S-IOdIJ IN THE FOLLOWING TABLE 3 NO ADDITIONAL SITE SPECIFIC ENGINEERING IS REQUIRED WHEN ExIsT Nv OPENINGS / PROJECTIONS ARE BOTH SMALLER THAN THOSE STATED ABOVE. TABLE 1- CRITERIA TO VERIFY THE NEED FOR SUE -SPECIFIC ENGINEERING LL/GSL MAX MAX (PSF) PROJECTION OPENING LENGTH WIDTH 10.20 III'-D" 81-0" 25 TO 50 14'-0" 6'-0" 60 121•CP 4'-0" 74 10'-0" 3' o" 82 2'-ID" - MIN (E) ROOENG BETWEEN O7NT. RAFTERS (E) W1J. SEEq1 OR TRUSSEEWrERE OCCURS NIDNE ABOMc (E) OONT. TRUSS TOP aHORD OR RWTES @ 24 O.C. (E) EAVE OH L (E) RAPIER OR TRUSS BACKSPIN f 24' MAX 6-9 MN 40-0" MAX NOTES: 1. EXISTING ROOF DESIGN LOADS: FDL = 3 PSF (MIN) TO 8 PSF (MAX) 2 NEW PATIO DESIGN LOADS: LL = 10 PSF MIX (NO SNOW LOAD) 3. PLACE "SIKA FLEX' OR SIMLAR MATERIAL. BETWEEN BRACKET AND COMPOSITE SHINGEE ROOFING TO PROVIDE SEAL 4. USE ALTERNATE BRACKET ORENTATION WHEN D < 12'. 5. USE THIS DETAIL WITH ROOF ERUU PER 5/L4.3 AND TABLES 1 NO 1A ON L61. C CONNECTION TO TOP OF EXI511NG ROOF 4 CONNECTION TO EXISTING ROOF NTs (E) STUD WA (3) Nz"IA LAG SCREW TYF1 TRIBUTARY AREA j MIN. TRIBUTARY AREA AFTER UIKLI:I ON PLAN BEAM CONNECTION TO HOUSE 0 NITS LEDGER OR WAL HANQR w/ FA964R5 PER TABLES 3A OR 4 ON L6.1 E 1" THICK MAX LATH AND PLASTER OR WOOD SIDING OR 1. 2 OR 3 COATS OF STUCCO SEE NOTE 3 RAFTER BRACKET AND ATTACHMENT PER 2/L6.2 � �I� I TI -1140 2xOR 3x NI-m ALUMINUM RAFTER 2 x WOOD STUD WALL SIM AT CONCRETE, BRICK NOTE: OR MASONRY WALL 1. WALL LEDGER SHALL BE: - NOMINAL LUMBER SIZE 2 x 6 (AT 2 x 61� MINIMUM RAFTERS), - NOMINAL LUMBER SIZE 2 x 8 (AT 3 x 8 MINIMUM RAFTERS), OR - KILN -DRY WOOD -FILLED 2 x 6uz" OR 3 x 8 ALUMINUM SECTION. 2. REFER TO TABLES ON LEA FOR SELECTION OF LEDGER MINIMUM SIZE TO ALLOW FOR ATTACHMENT OF RAFTER BRACKET TO LEDGER. 3. PLYWOOD SHEATHING DOES NOT COUNT TOWARD THIS V MAX. 1" THICK MAX LATH 1, 2 OR 3 COATS OF STUCCO SEE NOTE 6 I� G 3" x 8" x 0.042" BEAM t (3} SMS ff I Ea SIDE 3" x 8' RAFU BRACKET NM 1. USE OF THIS DETAIL IS LIMITED TO THE FOLLOWING: FOR LL/GSL = 10 PS~, W TTIB AREA TO CON ECRCiN - 100 FTz FOR LIL/GSL = 20 OR 25 PSF; MARL TRS AREA TO OC NhECIICN = 55 FTz FOR GSL = 30 PSF, MAX TRIG A+FA TO ODhAECfION = 45 Fi FOR GSL > 30 PSF, DETAIL IS NOT ALLOWED P. SEE PLAN FOR DEFINITION OF 1R IBURRY AREA 3. RAM MUST LINE UP WITH DUSTING FILL HEIGHT WAIL STD. NO OPENING ALLOWED 4. � (2) TI W/ 4 E>+M @ CONIC WALL, W/ 6- SPACING 5. USE 10" -IALL ffAC1KET k (2) V WELT KD-3 W/ 4 RED @ CMU WALL W/ E3" SPACING 6. PLYWOOD SHffAmw DOES NOT OOUNT TOAdARD THIS 1" wx (>) 1' THICK MAX LATH AND PLASTER OR WOOD SIDING OR 11 2 OR 3 COATS OF STUCCO SEE NOTE 1 CONNECTION OF RAFTER BRACKET TO LEDGER PER TABLE 38. 3C OR 3D ON L6.1 LEDGER TO WALL FASTENERS PER TABLE 3A OR 4 ON L6.1 (N) OR (E) 2 x WOOD LEDGER OR FASCIA, OR2x6�OR3x8 WOOD FILLED ALUMINUM MEMBER le SMS PER 3/1-6.2, TYP RAFTERR PER PLAN U BRACKET, SIM TO 2/1-4.3 OR 3/L4.3 N07'. 1. PLYWOOD SHEATHING DOES NOT COUNT TOWARD THIS 1" MAX. (-,) WALL CONNECTION L,F2 RAFTER TO WAIT LEDGER / FASCIA CONNECTION 1-1/2"=1'-O" "D" SEE TABLE 1 ON SL6.1 (E) BLOCKING BETWEEN (E) 1" THICK MAX LATH AND OONT. RAFTERS OR W SIDING R (E) NAILS SIM�N A35 - SEE TABLE 2 TRUSSES WHERE OCCURS 1, 2 OR 3 COATS OF STUCCO OR SD:M ON L6.1 FOR SCREWS AND SEE NOTE 2 NUMBER OF A35s RECO 1143RACKET AND I ATFPCI RMEM PER cs RAFTER PER PLAN 2A6.2 SEE NOTE 2d 2xOR 3x ALUMINUM (E) CONE TRUSS w1zRS TOP CHORD OR EXISTING FASGA RAFTERS @ 24 OC Bohm PLYWOOD SHEATHING (� NOTE ABOVE WHERE OCCURS E GEAR DIMENSION 10 BEAM (E) EAVE OH RAFTER OR TRUSS ESP 0E TAME 1 ON I$.7 24 MAX MN MAX 1. EXSTNG ROOF DESIGN LOADS: R DL = 3 PSF (MIN) TO 8 PSF(MA\) RJL/GSL = 10. 20, 25, 30, 40 OR 50 PSF 2 FASIENES TO BE LOCATED 4' MN FROM SPLICE IN (E) FASCIA BOAR AND f CLEAR FROM TOP Am BOTTOM OF (E) FASOA Bxu CONNECTION TO EDGE OF EXISTING ROOF cv cv FOR LL/SL = 10 PSF, USE (2)#14 SMS EA SIDE FOR LL/GSL = 20, 25, OR 30 PSF, USE (3)#14 SMS EA SIDE FOR GSL = 40, 50, 60, 72 OR 84 PSF, USE (4)114 SMS EA. SIDE U BRACKET, SIM TO I ! 12/L4.3 OR 3/1-4.3 ATTACHMENT PER TABLE 3A OR 4 ON L6.1 (E) STUD WALL @ 16" O.C. NOTE 1. USE LEDGER PER 2/1-6.2 WHERE RAFTER SPACING EXCEEDS EXISTING STUD SPACING. 2. PLYWOOD SHEATHING DOES NOT COUNT TOWARD THIS 1' MAX. �)ER TO STUD WALL Cr-ONNECTION1-1/2"=V-O" 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 co CD .S58.5 �Qr im OF CA0� DATE SIGNED: July 8, 2019 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305,11501 FAX 949,305.1420 �aP �+o OTM ES EXPIRES ON: JUNE 30, 2020 REVISIONS MARK DATE DESCRIPTION 4 STEL JOB # DA02-02 DATE 07108/19 DRAWN BY RC CHECKED MDS IAPMO 195 V 3.1.1 LATTICE STRUCTURES: CONNECTION DETAILS L6.2 LATTICE ATTACHMENT PER #8 SMS 7/L6.3 3 x 8 x 0.42 BEAM OR 3" SQ. STEEL BEAM DOUBLE BEAM (4) #14 SMS EA (6)-#14 SOS @ EA SIDE 89, BID, B12, RAFTER TO COLUMN TOP k BOT TOTAL = 24 B15 OR B16 (8 TOTAL) ' IV SO. OR 2" SO. OR 2 x 3" LATTICE @ 3" O.C. I I 5/8"0 HOLE WITH MIN. UP TO 6" O.C. MAX PLASTIC PLUG, AS H BRACKET PER i/54.5 I REQ'D, TYP. IT IS OR 1/1-4.3 ACCEPTABLE TO USE I I 3" OR 4° SQ. RAFTER - -- - --- — RAR IN E HOLETO SEVERAL— ----ALUM.-OR STEEL-POSF— ! I SCREWS, TYP. 1 3 x 3 x .024 (3) #14 SMS NOTES: CONNECTOR EACH SIDE THIS DETAIL IS TO BE USED AS AN ALTERNATE TO DETAIL 3/S6.3 NOTE: THIS DETAIL IS NOT TO BE USED IN LIEU OF A COLUMN. IATTIGE TUBE TO RAFTER STUB COLUMN TO DBL BEAM 'Fr BRACKET TO POST T 3°=1'-0" 4 CONNECTION 1-1/2"=1'-0" t-1/z"=t'-0" LATTICE ATTACHMENT PER 7/L6.3 1 2" MAX SPLICE WHERE OCCURS (6) 114 SMS 0 EACH (INT COL ONLY) HEADER TO COLUMN U BRACKET PER 2/L4.3 DBL RAFTER (12) FASTENERS PER DOUBLE BEAM B9, OR 3/L4.3 (4) #14 SMS EA RAFTER CONNECTTON BB16, B12, B15 OR TO COLUMN (8 TOTAL) 5/8"0 HOLE WITH 5/8"0 HOLE WITH PLASTIC PLASTIC PLUG, AS II I PLUG, AS REQ'D, TYP. IT IS REO'D, TYP. IT IS I II ® I EF 0 ACCEPTABLE TO USE ONE ACCEPTABLE TO I p I HOLE TO INSTALL SEVERAL USE ONE HOLE I� SCREWS, TYP. TO INSTALL ® I SEVERAL SCREWS, I II I O E '� j TYP. I Ii I ATTACHMENTS PER 2/1-6.3 I i O ! 1 (2) #14 SMS EACH Si SIE DBL BEAM B9, B10, B12, C T&B @32" I I PLACTES C HEERRE OC CCUR, I I 915 OR B16 SHALL STOP do FLUSH BELOW BEAM 3" OR 4' SQ. POST W/ OPTIONAL SIDE PLATE OR ARCH COL WHERE OCCURS 3" OR 4" S0. POST BRACKET SCALE 6'=I'-O" DBL RAFTER TO DBL BEAM DBL BE4M TO COL CONNECTION 1-1/2"=1'-0" ° 1FI( 3" WIDE BEAM TYP B2, RAM (2}#14 x 0.5" 0.5" EPOI �� B5, 811, B13 OR B14 1 2" MAX SPLICE SCREWS OR 8" BEAM (6) #14 SMS EA. SIDE WHERE OCCURS BST TO RAFTER SMS PER ELEVATION, M AT SIDE PLATE SP3 B ] (INT CAT. ONLY) %"0 PLASTIC PLUG, TYP- AT SIDE PLATE SP4IDE SEE NOTE 1. lid BRACKET PER 2/L4.3 W#14 x %" TEX SUERS n o OR 3/L4.3 E GPM PROVIDE FULL BEARING OF SINGLE 3 x 8 OR 3 x 3 BEAM ON POST. tl o BEAM BELOW ( Y %B"0 HOLE WITH PLASTIC PLUG, AS REQ'D, TYP. IT IS ACCEPTABLE TO 6y" SIDE PLATE F)k SIDE USE ONE HOLE TO INSTALL SEVERAL SCREWS, TYP. (2)+4 x %4" TEK SCREWS RAFTER EACH SIDE BRACKET TO (2) 114 SMS EA SIDE AT Cat" SIDE PLATE EA SIDE, SEE RAFTER 3' SQ. POST BOTTOM AND AT 32" OC MAX. TABLE 1 ON Sl.x OR Li.x (2}#14 x 3'4' TEK SCREWS SIDE �'� BRACKET TO EACH BEAM 6 SECTION A ELEVATION OPTIONAL STYCAN STOP I BELOW OF 3' SO. POST BETWEEN SIDE PLATES CAN STOP BELOW (4) TOTAL THE CONNECION SIDE PLATES DBL 2 x 6 BEAM BELOW OR DBL 3 x 8 BEAM BELOW B BEAM TO RAFTER BRACKET S BEAM TO POST CONNECTION NOTESO CO AT COLUMN B2, ADJUST SCREW LOCATION TO LOCATE SCREWS CONNECTION 1-1/2"=1'-0" 3/4"=1'-0' INTO THE FLAT PORTION / VERTICAL WALL OF BEAM 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 DATE SIGNED: July 8, 2019 OrA� 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 EXPIRES ON: JUNE 30, 2020 I REVISIONS I MARK I DATE DESCRIPTION I 4 STEL JOB # DA02-02 DATE 07108/19 DRAWN BY RC CHECKED MDS IAPM0195 V 3.1.1 LATTICE STRUCTURES: CONNECTION DETAILS L6.3 ADJACENT GRADE Tf POURED CONCRETE STEEL SLEEVE PER 4/0.2 AT POST TYPE C7, C8, & C9 PER TABLE 2 w m PER 4A; • ? V d < • re r w N h o �.� . ' 1 r c WIDTH - LENGTH IN S G. SCH IN BEAM SPAN TABLES NOTES: 1. THIS DETAIL CAN BE USED FOR STEEL POST TYPES C6, C7, C8, OR C9. 2. THIS DETAIL SHALL NOT BE USED FOR ALUMINUM POST TYPE Ct OR ALUMINUM POST TYPES C2 OR C5. 3. IT IS ACCEPTABLE TO EMBED THE STEEL POST DIRECTLY INTO THE FOOTING PER 5/0.1 INSTEAD OF USING THE POST SLEEVE SHOWN IN THIS DETAIL 4. THIS DETAIL CAN BE USED AT FREESTANDING OR AT ATFACHED STRUCTURES. 7 STEEL POST SLEEVE CONNECTION TO CONCRETE FOOTING TABLE 2 -ANCHORAGE SCHEDULE BRACKET DETAIL POSTTYPE FfG (IN) ANCHOR BOLTS (SEE NOTE 2) SEE NOTES ALUM T 1/0.2 CS SOG (2)-3/8" dia w/ 1-7/8" embed ALUM T 1/1-7.2 C3 ALL (21-3/8" dia w/ 2-7/8" embed ALUM T 2/1-7.2 C2 SOG (2)-3/8" dia w/ 1-7/8" embed 3 ALUM T 2/1-7.2 C2 ALL (2)-3/8" dia w/ 2-7/9" embed 3 ALUM T 2/1-7.2 C5 SOG (2)-3/8" dia w/ 1-7/8" embed 3 ALUM T 2/0.2 C5 ALL (2)-3/8" dia w/ 2-7/8" embed 3 STEELT 3/0.2 C6 SOG (2)-3/8"diaw/1-7/8"embed STEELT 3/1-7.2 C6 5 22" (2)-3/8" dia w/ 2-7/8" embed 1,3,4 STEELT 3/1-7.2 C6 524" (2)-1/2" dia w/ 3-1/4" embed 1,3,4 STEEL I NS 4/1-7.2 C6 5 30" (4)-1/2" dia w/ 3-1/4" embed 1A STEELINS 4/1.7.2 C6 534" (4)-5/8"diaw/4"embed 1A STEELINS 4/1-7.2 1 C6 235" (4)-3/4"diaw/4-3/4"embed 1.4 STEEL INS 4/L7.2 I C7, CB, C9 ALL (4)-3/4" dia w/ 4-3/4" embed 1,5 EMBED .5/17.1 C10,C11 I ALL I N/A NOTES: 1- "FTG (IN)" IS THE FOOTING DIMENSION REFERENCED IN BEAM SPAN TABLES ON SHEETS LB.xx.x 2 - ANCHOR BOLTS SHALL BE SI MPSON STRONG BOLT 2, STAINLESS STEEL (I CC-ESR 3037). H I LM KB-TZ SS CAN ALSO BE USED WITH A 4" SLAB, AND A REDUCED EDGE DISTANCE OF 3 1/2" (ICC-ESR-1917). 3 - IT IS ACCEPTABLE TO USE THE STEEL INSERT PER 4/L7.2 INSTEAD OF THE ALUMINUM T PER 2/L7.2 FOR POST TYPES C2 AND C50R INSTEAD OF THE STEELT PER 3/1-7.2 FOR POSTTYPE C6. BOLTS CAN REMAIN AS SPECIFIED IN THIS TABLE, BUT (4) BOLTS SHALL BE USED. SEE NOTE 6. 4 - IT IS ACCEPTABLE TO USE THE EMBEDDED POST DETAIL 5/L7.1 I N57EAD OF THE STEEL I NSERT OR STEELT FOR STEEL POSTS C6. 5 - IT IS ACCEPTABLE TO USE THE EMBEDDED POST DETAIL 5/L7.1 I NSTEAD OF THE STEEL INSERT FOR STEEL POSTS C7, C8 AND C9. ANCHORAGE OF POSTS TO SLAB OR FOOTING Y BRACKET PER 1/L7.2, 2/1-7.2, OR 3/L7.2. OR 4" STEEL POST. 3" STEEL OR ADJACENT3' ALUMINUM POST GRADE TYP. 7 BOLTS PER TABLE 2 = i ADJACENT GRADE TYP. S'MIN. ? En o " + W� O m a ' - '"a � ry m o a VN a �r URFD CONCRETE FOOTING \\. POURED CONCRETE WIDTH = LENGTH (IN) SEE FTG. SCHEDULE IN BEAM SPAN TABLES )90 A36 THREADED ROD W/- NUT EA. SIDE OF COL OR $4 REBAR, GR 40 MIN. SECURED IN PLACE NOTES: 1. THIS DETAIL IS TO BE USED FOR POST TYPES C10 & C11. 2. THIS DETAIL CAN ALSO BE USED FOR STEEL POST TYPES C6, C7, C8, C9 PER TABLE 2 ON L7.1. 3. THIS DETAIL SHALL NOT BE USED FOR ALUMINUM POST TYPES C1, C2, OR C5. 4. THIS DETAIL CAN BE USED AT FREESTANDING OR AT ATTACHED STRUCTURES. B STEEL POST EMBEDDED 1NT0 CONCREiE FOOTING 1"=t'-o" WIDTH = LENGTH IN SEE FTG, SCHEDULE 1 BEAM SPAN TABLE NOTES: 1. THIS DETAIL SHALL NOT BE USED FOR FREESTANDING STRUCTURES. 2. THIS DETAIL SHALL NOT BE USED FOR POST TYPE C7, C8, C9, C10, C11. S T BRACKET CONNECTION TO CONCRETE FOOTING 1"=1'-o" TABLE 1 ALTERNATE FOOTING DIMENSIONS FTG(IN) W=L=D (SEE NOTE 1) Aft I WxLxD (SEE NOTE 2) AIt2 WxLxD (SEE NOTE 3) Alt 3(ATTACHED) WxLx18" (SEE NOTE 4) AIt4 WxLx18" (SEE NOTE 5) AItS WxLx24" (SEE NOTE 6) Alt WxLx30" (SEE NOTE 7) AIt7 WxLx36" (SEE NOTE 8) AIt8 WxLx42" (SEE NOTE 9) 18 18x18x18 12x12x12 ISx18x18 18x18x18 16x16x24 14x14x30 13x13x36 12x12x42 20 20x20x20 12x12x12 21x21x19 25x25x18 19x19x24 17x17x30 15x15x36 14x14x42 22 22x22x22 16x16x16 25x25x18 33x33x18 21x21x24 19x19x30 17x17x36 16x16x42 24 24x24x24 20x20x20 28x28x18 43x43x1B 24x24x24 22x22x30 20x20x36 18x18x42 26 26x26x26 23x23x23 32x32x18 31x31x24 24x24x30 22x22x36 21x21x42 28 28x28x2B 25x25x25 35x35x18 38x38x24 27x27x30 25x25x36 23x23x42 30 30x3Ox3O 28x28x28 39x39x18 30x3Ox3O 28x26x36 26x26x42 32 32x32x32 30x30x30 43x43x18 37x37x30 30x30x36 28x28x42 34 34x34x34 32x32x32 47x47x18 33x33x36 31x31x42 36 36x36x36 34x34x34 SIX 51x18 36x36x36 34x34x42 38 38 x38x 38 37x37x37 5Sx55x18 43 x43x36 36x36x 42 40 40x40x40 39x39x39 60x6ox18 39x39x42 42 42x42x42 41 x41x 41 64x 64x19 42 x42x42 44 44 x 44 x 30 46 46 x46x30 48 48x48x30 50 50 x 50 x 30 52 52x52x30 54 54x54x30 56 56x56x30 58 58x58x3C 60 60x60x30 62 62 x 62 x 30 64 64 x 64 x 30 66 66x66x30 68 68 x 68 x 30 70 70x70x30 72 72x72x30 74 74x74x30 76 76 x 76 x 30 78 78x78x30 80 80 x BO x 30 82 82 x 82 x 30 84 84 x 84 x 30 86 86x86x30 88 SBx88x30 90 90 x 90 x 30 NOTES: 1- "FTG (IN)" IS THE FOOTING DIMENSION REFERENCED IN BEAM SPAN TABLES ON SHEETS SB.xx.x OR LB.xxx. 2 - "ALT 1" IS THE FOOTING DIMENSION BASED ON THE "FTG (IN)" DIMENSION. NOTETHAT W=D=L 3 - "ALT 2" 15 THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN A 3.5" MI N THI CK SLAB IS PRESENT ABOVE THE F0071 NG. NOTE THAT W =D=L 4 - "ALT 3" I S THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING 15 KEPTTO AN 18" DEPTH FOR UPLIFT DE51 GN ONLY. THIS VALUE IS TO BE USED ONLY AT ATTACHED PATIO STRUCTURES. NOTE THAT W=LAND D=18". 5 - "ALT 4" I S THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPTTO AN 18" DEPTH. NOTE THAT W=L AND D=18". 6 - "ALT S" 15 THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPTTO AN 24" DEPTH. NOTETHAT W=L AND D=24". 7 - "ALT 6" 15 THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPTTO AN 30" DEPTH. NOTETHAT W=L AND D=30". 8 -"ALT 7" ISTHE ALTERNATE FOOTING DIMENSION REQUIRED WHENTHE FOOTING IS KEPTTO AN 36" DEPTH. NOTETHAT W=LAND D=36". 9 - "ALT B" IS THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPTTO AN 42" DEPTH. NOTETHAT W =L AND D-02". �F011Ni]ATIO)T1 TABLES TABLE 3 - (MAX WIND SPEED:13OMPH, EXP C) MAXIMUM POST SPACING WHEN PATIO COVER IS INSTALLED ON SLAB ON GRADE TRIG WIDTH LATTI CE FRAMING LL,/GSL (psf) GSL (psf) 10 psf 20 psf 25 psf 30 psf 5' 13'-7" 11'-0" 10'-4" 9'-0" 6' 11'4" 9'-9" 9'-0" 8'-4" 8' 8'-6„ 8'-6" T-6" T-0" 9' 74-T, 8'-0" T-0" NP 10, 6'-9" T-6" NP NP 11' 6'-2" 7'-0" NP NP 12' 5'-8" 6'-6" NP NP NOTES: 1- "NP" I NDI CATES THAT A FOOTING IS REQUIRED, AND THE PATIO COVER CANNOT BE SUPPORTED ON A SLAB ON GRADE. 2- FOR LIVE OR SNOW LOADS HIGHER THAN THE ONES SHOWN ON THIS TABLE, A FOOTING IS REQUIRED AND THE PATIO COVER CANNOT BE INSTALLED ON SLAB ON GRADE. TABLE 4- (MAX WIND SPEED: 130MPH, EXP C) MAXI MUM TW O POST ATTACHED STRUCTURE W I DTH WHEN PATIO COVER IS INSTALLED ON SLAB ON GRADE TRIBWIDTH (ft) LATTICE RAFTERS UJGSL(psf) GSL(psf) 10 psf 20 psf 25 psf 30 psf 5 27-4- 22'-0" 20'_8" 18'-0" 6 22'•8" 19'-6" 18'-0" 16'-8" 7 19'-4" 11.-0" 16'-0" 15'-0" 8 17'-0" 17'-0" 15'-0" 14'-0" 9 15'-2" 16'-0" 14'-0" NP 10 13'-6" 25'-0" NP NP 11 12'-4" 14'-0" NP NP 12 11'-4" 13'-0" NP NP B T BRACKET CONNECTION TO SLAB ON GRADE 1"=r-0' � g � AstM Asoo GRADE a r INSERt TO PLAN g its BASE PL 3" STEEL POST �0.188" THICK MIN HSS INSERT 5) 3'4'0 BOLTS 0' SQ. x %" BASE PL NOTES. ELEVATION & 9 1. THIS BRACKET IS TO BE USED WITH POST TYPE C7, CS & C9, AND WITH C6 (WHEN FOOTING SIZE IS 25" OR LARGER). 2. SEE TABLE 2 ON S7.1 FOR ATTACHMENT TO FOOTING/SLAB. 3. INSTALL 1Y4 x 1Y, x K HDG WELDED WASHER PLATE WHEN HOLE DIAMETER IS MORE THAN X BIGGER THAN ANCHOR BOLT DIAMETER. 4. THIS BRACKET CAN ALSO BE USED FOR POST TYPE C2, C5, OR C6 (ALL FOOTING SIZES) SEE TABLE 2 ON L7.1 AND 7/1-7.1 FOR ANCHORAGE REQUIREMENT'S. STEEL POST SLEEVE FOR POSTS C7, CS, CO 3/4"=1'-o" 3" ALUMINUM OR ,- (� rBRACKElNE OF "P ALUMINUM POST � BRACKET TO BE PARALLEL TO HOUSE WALL ADJACENT GRADE I 4 /-'T" BRACKET PER 1/0.2, WHERE OCCURS I s 2/1-7.2 OR 3/0.2 6" MIN. IX[STING OR NEW SLAB ON SEE GRADE. fc = 2,500 PSI MIN. NOTE 6 SEE NOTE 6 EDGE OF SLAB \-BOLTS PER TABLE 2 WHERE OCCURS NOTES: 1. THIS DETAIL CAN BE USED WITH POST TYPES C1, C2, C5, OR C6. 2. TABLES 3 AND 4 IN THIS DETAIL CAN BE USED FOR FREESTANDING STRUCTURES AND/OR COMMERCIAL APPUCATIONS, BUT THE STRUCTURE CANNOT BE INSTALUM ON A SLAG ON GRADE AND REQUIRES A FOOTING PER S6.xx.x. 3. THIS DETAIL SHALL NOT BE USED FOR POST TYPE C10 & C11. 4. SEE "SLAB ON GRADE USED AS A FOUNDATION SYSTEM' NOTES ON GOA FOR MINIMUM OVERALL DIMENSION OF SLAB AND ACCEPTABLE CRACKING AND CONTROL/EXPANSION JOINTS CRITERIA. 5. WHEN THE PATIO COVER IS INSTALLED ON A SLAB ON GRADE (RESIDENTIAL APPLICATIONS ONLY), THE MAXIMUM POST SPACING IS THE LOWEST OF THE 'MAX POST SPACING (SPAN)' SHOWN ON LB.XX.1 AND THE MAXIMUM POST SPACING SHOWN IN TABLE 3. 6. SEE NOTE 2 ON 4/0.1 FOR ALTERNATE. 7. THIS DETAIL CAN ONLY BE USED IN AREAS WITH A FROST DEPTH EQUAL TO ZERO. B. SEE 'GENERAL NOTES - SLAB ON GRADE USED AS A FOUNDATION SYSTEM" NOTES ON GOA FOR MORE INFORMATION. ALUM ALLOY 6os3-Ts 2 OR TEK DR TEK SCREWS, EA. SIDE, TYP. N I j %"0 HOLE EA. SIDE 0.ow TYP. I D35a 5.662' TYP. Nam= 1.-BRACKET T:ENGTK IS 13Y 2. THIS BRACKET IS TO BE USED WITH POST TYPE C1. WITH OR WITHOUT SIDE PLATES PER SP3 OR SP4. 3. SEE TABLE 2 ON L7.1 FOR ATTACHMENT TO FOOTING/SLAB. 4. INSTALL 14 x tY xY HOG WASHER PLATE AT ANCHORS FOR 130 MPH y ALUMINUM T-BRACKET OR POST 01 3"=1'-o" ALUM ALLOY 6063 T6 4-#14 SMS nix OR TSCREWS, I� � I} EA. SIDE, TYP. :r WO HOLE EA. SIDE 0.094' TYP. 0.750" 5.50' TYP. NOTES: 1. BRACKET LENGTH IS 2.75". 2. THIS BRACKET IS TO BE USED WITH POST TYPE C2 OR C5, WITH OR WITHOUT SIDE PLATES PER SP3 OR SP4. 3. SEE TABLE 2 ON L7.1 FOR ATTACHMENT TO FOOTING/SLAB. 4. INSTALL %x IX x A HOG WASHER PLATE AT ANCHORS FOR 130 MPH. 5. STEEL 7-BRACKET PER 3/1-7.2 CAN BE USED IN UEU OF THIS BRACKET. (j)ALUMINUM T-BRACKET FOR POSTS C2, C5 3"=1'-0" 0.75, 4.00" LAPM A50Q GRADE B 4-Wf O HOLES TYPM(ef 1 �ife'0 & 2-3ie HOLES. TYP EA SIDE 01 -CENTERUNE OF T'BRACKET TO PLAN BE PARALLEL TO 3.50" 1 OU' HOUSE WALL TYP 2-N-0 HOLES FOR c Wo M.B. TYP. N uY - N 0 ELEVATION -- NOTES: 1. THIS BRACKET IS TO BE USED WITH POST TYPE C6 WHEN FOOTING SIZE IS 24" OR SMALLER, WITH OR WITHOUT SIDE PLATES PER SP3 OR SP4. 2. BRACKET CAN ALSO BE USED WITH POST TYPE C2 OR C5 PER TABLE 2 ON L7.1 AND 2/0.1 3. SEE TABLE 2 ON L7.1 FOR ATTACHMENT TO FOOTING/SLAB. STEEL T BRACKET FOR POST CS 3"=1'-0" ATTACHED & FREESTANDING LATTICE COVERS - 10 PSF SNOW LOAD OR LIVE LOAD -110 MPH - EXP. B & C B5 12G3'.SQ. AUM W/ ULCHANNEL 610 DBL2x6.5x0.032 811 3x8x0.042 B9 DBL 2 x6.5 x0.042 612 DBL3x8x0.042 Bi3 14GASTL INSERT ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING TRIB WIDTH WIND EXP MAX POST SPACING (SPAN) FTG (IN) MIN POST PPE MAX POST SPACING (SPAN) FTG (IN) MIN POST T1 POST MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TOPE MAX POST SPACING (SPAN) FTG (IM MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN (POST TYPE $ 110 B 16'-9" 15 Cl 14' 7" 29 C7 I 14'-1 U' 15 Cl 14'-10" 28 C7 15' 4" 15 C1 15'�" 28 C7 19-91 15 C1 1$'-0" 29 C7 21'-B" 16 Cl 21'-6" 31 C7 20'-9" 16 Ot 20'-T 31 C7 110 C 16'-9" 17 14'-T' 31 CB 14'-10" 17 14'-6 30 15' 4" 17 15'-1" 30 18'-0" 18 1T 6 T 21'-B" 19 21'-2" 33 CB 2V-T 18 20'-7 33 CB 110B 15'-3" 16 c1 28 C7 13'7" 15 c1 13'-7 28 c7 14'-1" 15 14'-1"2B16'-0" c7 16 ci 16'4, 29 c7 1V-9" 17 cz 19'-9" 3D C7 19'-0" 17 ct 19'4r' 30s C7 110C 15'-3" 1 B 30 CS 13'-T' 17 13'-T, 29 W-1" 17 13'-9" 29 16'�" 18 16,-T 30 19'-9" 1919'-3" 32 19'-0" 19 16' 6 32110B 14'-2" 16 C130 26 C7 177" 15 C1 12-T' 28 C7 13'-1" 15 C1 13'-1" 2B C7 15'-2' 16 C1 15'-2" 2918'-4" C7 17 C2 18'4" 30 C7 17'7' 171T7" 30T 110C 14'-2' 18 12'-7" 17 12'-3" 29 13'-1" 17 12'_9" 29 15'-2' 19 14'-1V' 3D 18'�" 20 17-1D" 31 1T-T' 19 17'-1" 31C7 13'-3" 16 C1C7 N124 29 11'-9" 16 C1 11'-9" 28 C7 12'-3" 16 C1 12'-3" 2B C7 14'4' 17 C1 14'-3" 29 C7 17'-2" 18 C2 'UT2'3116'-8" C7 18 C2 16'-T 31 C7 110C IT-3" 19 29 11'-9" 18 11'-6" 28 12'-3" 18 12'-0" 28 14,4, 19 13'-10" 29 1T-2" 20 16'-9 31 16-6 20 16'-1" 31 9 110 B 12'7" 17 C229 29 07 11'-2" 16 C1 11'-2" 29 C7 117 15 01 11-7" 29 C7 13'-0" 17 C2 13'-6" 30 C7 16'-3" 18 C5 16'-3" 31 C7 15'-0" 1 B 15'-6" 31 C7 110C 12'7" 19 11'_2" 18 10'_10" 28 11'_T' 1 B 11'_3" 2B 13- 19 13'"1 30 16'_3,. 21 15.-7. 31 151-T 20 15%7' 31 10' 110 B 12'-0" 17 C2 10'�" 30 07 10'-7" 16 Cl 1U-7" 29 07 111-T 16 Cl 11'-0" 29 07 12'-9" 17 02 12'-9" 30 07 15'-4" 16 05 1514, 32 07 14'-9" 1$ 05 14% 32 C7 110 C 12'-0" 19 10'-4" 30 10'-7" 19 10'-3" 29 11'-0" 19 10'-0" 29 12'-5' 20 12'-0" 30 15'�" 21 I5'-1" 32 W-9" 21 14'4" 32 11' 110 B 11'�" 17 C2 9'-10 3D C8 10'-1" 17 Cl 19-1" 29 07 10'-0" 17 Cl 10'-0" 29 07 12'-2' 18 02 12-2" 31 07 14'-B" 19 05 14'-8" 32 07 14'-1" 19 05 14'-1" 32 C7 11 D C 11'4, 20 9'-10 3D 10'-1" 19 9'-10" 29 1 D' 6 19 10'-1" 29 12'-2" 20 11'-10" 3D 14'-B" 21 14' 4" 32 14=1" 21 13' 8" 32 12' 110E 10'-10" 1B C2 S-0 30 06 9'-8" 17 C2 Y-6" 29 07 9'-0" 17 02 9'-6" 29 07 11'-8" 18 02 11'-8" 31 07 14'-1" 19 05 14'-i" 32 07 13'-G' 19 05 13'-0i 32 C7 110C 1U-10" 20 9� 30 9'B" 19 9'-0" 29 9'�" 19 9'-2" 29 11'-B" 20 11'�" 31 14'-1" 22 1T-9 32 13' 21 13'-2" 32 V/ 312 /RT B14 GA STL INSERT 8DBL614 GA STL INSERT618 bBL 12 GA STL INSERT818 12 GA STL U-IN E 619 DBL 12 GA STL U-INSERT ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN TRIB WIND POST FTG POST FTG POST FTG POST FTG POST FTG POST FTG POST FTG POST FTG POST POST FTG POST POST FTG POST WIDTH EXP SPACING (IN) POST SPACING (IN) POST SPACING (IN) POST POPE SPACING (IN) POST TYPE SPACING (IN) POST n PE SPACING ON) POST TYPE SPACING ON) IPOST POPE SPACING (IN) T PE SPACING (IN) PPE SPACING 0N) TYPE (SPAN) TYPE (SPAN) TYPE (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) 110 B 22'4" 17 22'-B" 31 C7 29'-2" 18 29'-2' 33 C8 32'-T 19 32'-0" 34 CB 25'-10" 17 C6 25'-10" 42 CB 32'-0" 18 C6 32'-0° 49 C8 6 Cl C2 C5 110 C 22'�" 19 22'-1" 33 C8 29'-2" 21 28'-6" 36 C9 32'-0" 21 31'-2" 36 C11 22'-11' 19 C6 22'-11" 41 C11 28'-11" 21 C6 28'-11' 47 C11 110 B 20'-8" 17 31 26'-8" 19 264r' 33 C8 29'-2" 19 29'-2" 33 C8 24'-3' 17 C6 24'-3" 48 CB 30'-7'' 19 C6 3V-7" 51 CB 6' C2Y17�-O" C7 C5 CS 11D C 20'-&' 20 32 26'-8" 21 26'-0" 35 C9 29'-2" 22 28'-6" 36 C9 21'-7- 20 C6 21'-7" 42 C9 27'-2" 21 C6 2T-2' 49 C9 110 B 19'-2" 1B 31 24'$" 19 24'-0" 33 27'-1" 20 27'-1" 33 CB 23-1° 1B C6 23-1" 49 CB 29'-1" 19 C6 29'-1° 53 CB T C232 07 05 08 05 110C 19'-2' 2D 24'-8" 22 24'-1" 34 2T-1" 22 26'-4" 35 C9 20'-0" 21 C6 20'-0" 47 C9 25'-10' 22 C6 25'-10' 51 C9 110 B 18'-0" 1B 31 23'-2" 20 23'-2" 33 25'-3" 20 25'-3" 34 22'-1" 18 C6 22'-1" 51 2T-1D" 20 C6 2T-10' 54 6' C2C7 C5 C8 C5 C8 C8 CB 11 D C 1 B'-0" 21 31 23'-2 22 22'-7 33 25'-3" 23 24'�" 34 19'-7° 21 C6 19'-7" 49 24'�" 23 C6 24'-B" 52 110 B 17--0" 18 32 21'-10" 20 21'-10" 34 23'-10" 21 2T-10" 35 C9 21'-2° 19 C6 21'-2" 52 C9 26'-9" 20 C6 26'-9' 56 C9 9 C5 C7 C5 CB ;I C5 110 C 17'-0" 21 17'-0" 31 21 '-10" 23 21'-3" 34 23'-1V' 23 23'-3" 34 CB 18'-10" 22 C6 18'-10" 50 CB 23'-9" 23 C6 23'-9° 54 C8 110 B 16'-1" 19 16'-1" 32 20'-9" 20 20'4' 34 22'-B" 21 22'-8" 35 20'-0' 19 C5 20'-6" 53 25'-10" 21 C6 25'-10' 57 10' C5 07 05 08 05 09 09 C9 110 C 16'411 21 16'-1" 32 20'-V 23 20'-2" 34 22'-0" 24 22'-1" 35 18-2° 22 Cb 1B'-2" 51 22'-11' 24 C6 22'-11' 55 110 B 15'-4" 19 15'-4" 32 19'-9" 21 19'-9" 35 21'-B" 21 21'-0" 36 19'-10" 20 C6 19'-10" 54 25'-0" 21 C6 25'-0" 58 C9 11' C5 07 05 C9 05 09 09 110 C 15'-4" 22 15'-4" 32 19'-9" 24 1W-3" 34 21'-8" 24 21'-1" 35 17'-7' 23 C7 17'-i 52 22'-2" 24 C7 22'-2" 56 110 B 14'-9" 19 14'-9" 32 19'-0" 21 19'-0" 35 20'-8" 22 20'-8" 36 C11 19'-3" 20 C6 19'-3' 55 C11 24'-3" 22 C6 24'-3" 59 C11 12' C5 09 05 09 05 110C 14'-9" 22 14'-9" 33 19'-0" 24 1$'-6.. 35 20'�" 25 20'-2" 36 C10 1T-1' 23 C7 1T--1" 53 C10 2V-7" 25 C7 21'7 57 C10 NOTES: 1 - WHEN THE PATIO COVER IS INSTALLED ON A SLAB ON GRADE (RESIDENTIAL APPLICATIONS ONLY), THE MAXIMUM POST SPACING IS THE LOWEST OF THE "MAX POST SPACING (SPAN)" SHOWN ABOVE AND THE MAXIMUM POST SPACINGS SHOWN ON DETAIL B/L71 2 - IT IS ACCEPTABLE TO SUBTITUTE COLUMNS W/ HIGHER NUMBERS W/ THOSE SPECIFIED IN THE TABLES SHOWN. il -7 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 5 5885 qTF OF CAI-%F DATE SIGNED: July 8, 2019 07-x 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 �aP Mo ES OTM EXPIRES ON: JUNE 30, 2020 REVISIONS MARK DATE DESCRIPTION 4 STEL JOB # DA02-02 DATE 07108/19 DRAWN BY RC CHECKED MDS IAPM0 195 V 3.1.1 LATTICE STRUCTURES: BEAM SPANS & FOUNDATION SIZES 10 PSF LUSL, 110 MPH L8.1 0.1 ATTACHED & FREESTANDING LATTICE COVERS -10 PSF SNOW LOAD OR LIVE LOAD -120 MPH - EXP. B & C 85 3"SQ. ALUM W/ DBL2x6.5x0.032 812 B11 3x8x0.042 B9 DBL2x6.5x0.042 612 DBL3x8x0.042 3x8x0.042W/ 613 14 GA STL INSERT GA STL"U" CHANNEL ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING MAX MIN. MAX MIN. MAX MIN. MAX MIN. MAX MIN. MAX MIN. MAX MIN. MAX MIN. MAX MIN. MAX MIN. MAX MIN. MAX FTG. MIN. TRIB WIND POST FTG- POST POST FTG. P057 POST FTG. POST POST FTG. POST POST FTG. POST POST FTG. POST POST FTG. POST POST FTG. POST POST FTG. POST POST FTG. POST POST FTG. POST POST POST WIDTH EXP. SPACING (IN.) TYPE SPACING (IN.) TYPE SPACING (1N.) TYPE SPACING ON_) TYPE SPACING (IN.) TYPE SPACING (IN) TYPE SPACING (IN.) TYPE SPACING (IN .) TYPE SPACING (IN.) TYPE SPACING ON.) TYPE SPACING (IN.) TYPE SPACING ON.) TYPE (SPAN)--..._ -- (SPAN) — — - .. (SPAN)- . — -(SPAN) — _(SPAN). --. _[SPAN) - (SPAN) _ (SPAN) . - .... [SPAN) _- (SPAN) - .. [SPAN) _- 1206 16'2" 16 14-T' 31 C8 14'-10" 15 14'-10" 30 15-4, 15 IVA' 30 1& 0" 18 18'-0" 31 C7 21.4- 17 C1 21' 8" 33 C8 20'-9" 17 C7 20'-0" 32 C7 5 120 C 1614, 18 Cl C1 IV-1" 31 C7 15-Z' 18 Cl 14'-7" 31 C7 1T•-B" 19 C1 19'-0" 34 C8 14'-T' 33 CID 14' W, 18 17'-0" 31 CB 21 r 20 20-7 34 2U4' 20 120 B 15'-3' 16 13'-3" 30 C8 13-T' 18 13'T' 29 74-i" 16 14'-1" 29 164' 17 16'-C 30 19'-9" 18 191•9" 32 C7 19'-V 18 CI 19-4r 32 07 6 i20C 15'U 19 Cl C1 C7 C7 C1 C7 13-3 32 C9 13!4" 15 12'-10" 31 13'-10" 1 1C1 13'-0" 31 162" 19 IT-T' 30 1V-7" 21 16'-9" 34 C8 16'$" 20 C2 lV4Y- 33 C8 1208 14'-2 i7 i2'-0" 29 C7 12'-T" 16 12 7" 29 13'-1` 16 ITV 29 16-2" 17 15'-7' 30 C7 1B'-4" 18 C2 18' 4" 31 G7 i7-7" 18 C2 17'•7" 31 C7 T 120C 13'-10 19 C1 C1 C7 Cl C7 C1 161-V 33 124" 31 C9 174" 19 12'-0" 30 12'-10" i9 12'-4" 30 Is.-T 20 144' 30 iB-l" 21 17'.4" 33 CB 17'-3" 21 1208 i3'-3 17 11'-7" 29 C7 11=8 17 11'-9 28 12-3 17 12 3" 28 14'-3" 18 Ci 14-3" 28 C7 17-2" 19 C2 17'2 31 C7 16� 18 18-8 30 C7 B 120C IT-O" 20 C1 C1 114, 30 C7 12'-l" 19 Cl C7 i6 T' 21 15'T' 32 11-T' 31 CB 11'-8" 19 1T-7" 30 14'-1" 20 C2 13'-e" 29 17'-0" 22 18•-3" 32 120 B i2'-7" 18 11'-0" 29 07 11'-2" 17 1F-7' 29 11'7" 17 11'-7" 29 13-W 16 13'-8" 30 C7 IV-3" 19 CS 78-3" Si C7 15'$' 19 15'$ 31 C7 9' 120C 12-3" C1 10-7 29 C7 11'4" 20 C1 11.0.. 29 C7 C2 14'-8" 32 11'-0 30 Ce i1'0" 20 13'-3" 21 12'j3" 30 16'-T 22 15'-4" 32 15-3" 22 120 B 12'-0 i6 10 4" 3 C7 VY-7" 17 IV-T' 29 11-7 17 11-0" 29 12'-9" 18 C2 12'-9" 30 C7 15 19 C5 15'-4' 32 C7 14'-9" 19 CS i4-9 S7 C7 1D' C2 Cl C7 C1 C7 14'-0 31 120 C 11'� 21 10a1" 30 CB 1D$ 20 1D-1" 29 101, 20 50�1" 29 12'-7 21 12-1" 30 15'-2" 22 14'•T' 37 14'-0 22 120E 114' 18 Y-10" 30 10'-l" 17 i0'-1" 29 10'-8" 29 12-2 19 12'-2 31 C7 14'�" 20 C5 14'8 32 C7 t4=1" 19 14'-1" 32120C C7120 9'-8" 29 12d1 21 11'-T' 30 14'� 23 14' Q 32 13•10"C5 11'-2" 21 C2 9'-10" 30 CB 10'-0" 20 C1 g,T,C7 C1 C7 B 10'-10" 1B 9 6 30 8'$ 18 9 8" 29 il C7 14'•1" CS 05 C7 12' C2 CB C2 C2 C7 C2 12'-9 32 120C 10'•$" 21 9'-0" 31 9'T' 21 9'-2'3007 B'-9" 30 11'$ 22 11'•1" 3i 13-10 23 53'�4" 32 C8 13'-3" 23 312 B19 B14 GA STL INSERT B15 DBL14 GA STL INSERTBS6 DB L12 GA STL INSERTB18 12 GA STL U-IN E/RT DBL 2 GA STL U-NSERT ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING MAX MIN. MAX MIN. MAX MIN. MAX MIN. MAX MIN. MAX MIN. MAX MIN MAX MIN MAX MIN MAX MIN TRIB WIND POST •FTG. POST IFTG. POST FTG. POST FTG. POST POST FTG. POST POST FTG (POST POST FTG POST POST FTG POST POST FTG POST WIDTH EXP. SPACING (IN.) POST SPACING (IN) POST SPACING (IN.) POST SPACING ON,) POST JFTG. SPACING (IN) POST TYPE SPACING (IN.) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE (SPAN) TYPE (SPAN) TYPE (SPAN) TYPE (SPAN) TYPE (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) 120 B 22'-0" 18 C1 22'-B" 33 C8 29'-2" 19 29'-Z' 35 C9 32'-0" 20 3Z-D" 36 24'-B' 18 C6 24'-8" 42 C11 31'-2" 19 C6 31'-2' 49 C91 5 C2 CS C11 12D C 22'4' 20 C2 21'-0" 35 C9 28'-9" 22 2T-T 37 C11 32'-0" 23 3p'-3- 38 21'-7" 20 C6 21'-7" qp 27'-3" 22 C6 27-3' 46 120 B 20'-0" 18 20'�" 32 C7 26'-8" 20 26'-8" 35 C9 29'-2" 20 29'-2" 35 co 2T-3° 18 C6 2T-3" 47 C9 29'-4" 20 C6 29'-4' 50 C9 6 120 C 29-4" 21 C2 C5 CS 19'-6" 34 CB 26'-3" 23 25-3" 36 C11 29'-7' 23 27' 6" 37 Gil 20'-4" 21 C6 29-4- 41 C11 25'-B" 23 C6 25'-8" 4B C11 120 B 19'-2' 19 19'-2 32 C7 24' B" 20 24' 8" 34 CB 27'-1" 21 2T-1" 35 C9 27-1' 19 C6 22-1' 48 C9 2T-10° 20 C6 27'-10' 52- C9 T 120 C 18'-10" 21 C2 CS CS 18'-2" 33 C8 244" 23 23'-6" 35 C9 27'-l" 24 25'-8" 37 C11 19'-4" 22 C6 19' 4" 46 C11 24'-0" 23 C6 24'-4 S0 C71 120 B 18'-0" 19 16'-0" 31 C7 23-2" 21 23'-2" 33 CB 25'-3" 21 25-3" 34 CB 21'-1" 19 C6 21'-1" 50 CB 26'-7" 21 C6 26'-7' 54 CB B, 120 C 17'�" 22 C2 CS C5 17'-1" 33 C8 22'-9" 24 zF- 35 C9 25'-3 25 24'-0" 36 C11 16'-0' 22 C6 18'-0" 48 C11 23'-3' 24 C6 23'-3' 51 C11 120 B 17'-0" 19 17'-0" 32 21'-10" 21 21'-10" 34 CB 23'-10" 22 35 20'-4' 20 C6 20'4" 51 C9 25'-7" 21 C6 25'-7' S5 C9 9, 120 C 16'�" 22 CS C7 CS CS35 C9 16'-11, 32 21'-6" 24 2U-8- 34 C9 23'-1T 25 17'-9' 23 C6 17'-9" 49 22'-5" 25 C7 22'-5' S3 120 B 16'-1" 20 16'-1" 32 20'-9" 21 20'-9" 34 22'4" 22 35 19' 7` 20 CS 19'-7" 52 C9 24'-8" 22 C6 24'-0' 56 C9 10' 120 C 15'-10" 23 CS 15' 3" 32 C7 CS co CS35 C9 20'�" 25 19 g, 34 22S,. 26 tv-8,, 17'-2' 24 C7 17'-2" 50 21 W' 25 C7 21'-7- 54 120 B 16-4" 20 15'-0" 32 C7 19-9" 22 19'-9" 35 21'-B"k22C 36 19'-0' 21 C6 19'-O"120C 15'-2"23 CS CS C9 S35 C9 14'7 32 CB 19'-0" 25 16'-9" 34 21'-B 16-7" 24 C7 16'-T'120E 14'-9" 20 14'9" 33 19'-0" 22 19'-0" 35 20'-B" 36 C11 1B'-5- 2112' CS CB CS C9 120 C 14'-0" 23 14-0 32 18-8 26 1B'-0" 34 20'-0"S - 35 C9 16'-2' 24 C7 16'-2" 52 C9 20' 4" 2fi C7 20'�' 56 C9 NOTES: 1 - WHEN THE PATIO COVER IS INSTALLED ON A SLAB ON GRADE (RESIDENTIAL APPLICATIONS ONLY), THE MAXIMUM POST SPACING IS THE LOWEST OF THE "MAX POST SPACING (SPAN)" SHOWN ABOVE AND THE MAXIMUM POST SPACINGS SHOWN ON DETAIL 8/L7.1 2 - IT IS ACCEPTABLE TO SUBIITUTE COLUMNS W/ HIGHER NUMBERS W/ THOSE SPECIFIED IN THE TABLES SHOWN.