Loading...
BPAT2019-006478-495 CALLE TAMPICO C6 0 D Xfu Qu4a VOICE (760) 777-7125 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 10/9/2019 Permit Type/Subtype: PATIO COVER/CITY STANDARD/PRE-ENGINEERED - OPEN Owner: Application Number: BPAT2019-0064 JOSEPH REYES Property Address: 60612 LACE LEAF APN: LA QUINTA, CA 95586 Application Description: REYES / 72SF SOLID PATIO COVER AT REAR YARD Property Zoning: Application Valuation: $2,000.00 Applicant: Contractor: VALLEY PATIOS INC DBA VALLEY CONCRETE & A I RE TE /E�jVALLEY PATIOS INC DBA VALLEY CONCRETE & 77971 WILDCAT DR SUITE B 77971 WILDCAT DR SUITE B PALM DESERT, CA 92211 OCTn 9 2019D PALM DESERT, CA 92211 0 1. U a (760)203-4313 CITY OF La's QUINTA Llc. No.: 937811 DESIGN & DEVL=LOPMENT' DEPARTMENT° LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: License No.: 937811 Date: ❑ ! Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Da Owner. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the ork for which this permit is issued. W(have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: FALLS LAKE FIRE_AND_CASUALTY COMPANY Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: -1 Applicant:«_ WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalfthis application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above - mentioned prop rty for inspection purposes. rl q Date: / CS r 1 Signature (Applicant or Agent)� ���� Date: 10/9/2019 Application Number: BPAT2019-0064 Property Address: APN: Application Description: REYES / 725F SOLID PATIO COVER AT REAR YARD Property Zoning: Application Valuation: $2,000.00 Applicant: VALLEY PATIOS INC DBA VALLEY CONCRETE & ANDREW TEXTER 77971 WILDCAT DR SUITE B PALM DESERT, CA 92211 Owner: JOSEPH REYES 60612 LACE LEAF LA QUINTA, CA 95586 Contractor: VALLEY PATIOS INC DBA VALLEY CONCRETE & 77971 WILDCAT DR SUITE B PALM DESERT, CA 92211 (760)203-4313 Llc. No.: 937811 Detail: 72SF SOLID PATIO COVER AT REAR YARD [DURALUM]. THIS PERMIT DOES NOT INCLUDE ELECTRICAL INSTALLATIONS. 2016 CALIFORNIA BUILDING CODES. FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT PATIO COVER, STD, OPEN 101-0000-42404 0 $107.87 DESCRIPTION ACCOUNT CITY AMOUNT PATIO COVER, STD, OPEN PC 101-0000-42600 0 $106.26 Total Paid for PATIO COVER / COVERED PORCH / LATTICE 2019: $214.13 DESCRIPTION ACCOUNT QTY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT QTY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $0.50 Total Paid -for STRONG MOTION INSTRUMENTATION SMI: $0.50 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 ta Qaiwra 1:G\1 -j rh, UE11 PERMIT #�, `� l PLAN LOCATION: Project Address: CDOG lr'2 LJOC/ L, C4 . Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech Applicant Name: r) j'�`�>1/ 1Q, Address: —70�1 City, ST, Zip: Telephone: —160 .- 2�� — q Email: ar)A raw tos,cr om Valuation of Project $ is Contractor Name: a a New SFD Construction: Address: �C�-� -� Conditioned Space SF City, St, Zip CA Q Z- Garage SF Telephone: Patio/Porch SF r Email: Fire Sprinklers SF State Lie: City Bus Lic: Arch/Eng Name: Construction Type: Occupancy: Address: Grading: City, St, Zip Telephone: Bedrooms: Stories: # Units: Email: State Lie: City Bus Lic: Property Owner's Name: J O Q New Commercial / Tenant Improvements: Address: Cp0Q�o Z Lac 1--' i� Total Building SF City, ST, Zip U I h ck qZZ15 3 Construction Type: Occupancy: Telephone: —� 5 � CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 OFFICE USE ONLY # Submittal Req'd Rec'd Plan Sets Structural Calcs Truss Calcs Title 24 Calcs Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License Lace Leaf Court Driveway Reyes Residence 60612 Lace Leaf Ct a� La Quinta, CA 92253 Proposed Solid Alumawood Cover Existing Patio cover Solid �AC - CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE QArE197 7�1-25F Sriu D PA -no cAvEg- RT PICaa-- YApb t,�,"Wm-j L-4 Solid Cover 27' ,,- 5�Xc I I Reyes Residence 60612 Lace Leaf Ct La Quinta, CA 92253 Proposed Solid Alumawood Cover 44' 4" _ :iTY 0;:: LA Q?. �NV:. BUILDING DIVISION REVIEWED FOR CODE , COMPLIANCE VALLEY PATIOS LUXURY OUTDOOR LIVING Client: Joseph Reyes Address: 60612 Lace Leaf Court City/St/Zip: La Quinta, Ca 92253 Phone: ( Tel: (76o) 2O3-43t3 www.valleypatios.com 77-97t Wildcat Dr. Suite B Palm Desert, CA 92.211 License # 937811 Estimated By: JRN Acceptance By: Date: 10 ti Signature PATIO COVER SYSTEM AS MFG. POINT OF CONTACTS INFORMATION REQUESTS SHALL BE DIRECTED AS FOLLOW: CONTRACTORS: PLEASE CONTACT DURALUM 26030 ACERO SUITE 200 PHONE (949) 305-1150 BUILDING DEPARTMENTS: PLEASE CONTACT 4STEL ENGINEERING MISSION VIEJO, CA 92691 FAX: (949) 305-1420 HOME OWNERS: PLEASE REQUESTANIY INFORMATION THROUGH YOUR CONTRACTOR STRUCTURAL ENGINEER OF RECORD: DUSTIN K: ROSEPINK, SE 5885 POINT OF CONTACT: MARIE-DOMINIQUE SETA, SE 5987 DESIGN PARAMETERS GOVERNING CODES: THE DESIGN OF ATTACHED AND FREESTANDING COVERS SHOWN IN THIS REPORT COMPLIES WITH THE FOLLOWING CODES: - 2012/2015/2018INITERNATIONAL BUILDING AND RESIDENTIAL CODES, T 2013/2016 CALIFORNIA BUILDING AND RESIDENTIAL CODES, - ASCE/SEI 7-10 and 7.16 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, • 2015 ALUMINUM DESIGN MA96Z LIVE LOADS DESIGN PARAMETERS: IT IS THE RESPONSIBILITY OF THE ENTITY SUBMITTING THE DRAWINGS FOR THIS PROJECT TO VERIFY LIVE LOADS WITH THE LOCAL AUTHORITY HAVING JURISDICTION 1. IN RESIDENTIAL APPUCATIONS, ROOF LIVE LOAD CAN GENERALLY BE TAKEN AS 10 PSF PER IRC/ CRC APPENDIX H, SECTION A11105.1 OR IBC/ CBC APPENDIX I, SECTION 105.1 2. IN COMMERCIAL APPLICATIONS, ROOF LIVE LOAD CAN GENERALLY BE TAKEN AS 20 PSF PER IBC / CBC CHAPTER 16 WIND SPEED DESIGN PARAMETERS: 1. THE FREESTANDING AND ATTACHED COVERS NOTED HEREIN ARE DESIGNED AS "OPEN STRUCTURES," IN ACCORDANCE WITH ASCE/SEI7. 2. FREESTANDING COVERS SHALL NOT BE ENCLOSED WITH ANY TYPE OF SOLID OR MESH MATERIAL, UNLESS SPECIFICALLY DE51GNED BY A REGISTERED PROFESSIONAL ENGINEER. 3. COVERS SHALL NOT BE INSTALLED IN AREAS NEAR HILLS, RIDGES AND ESCARPMENTS AS DEFINED IN ASCE/SEI 7, SECTION 26.2, UNLESS SITE SPECIFIC ENGINEERING IS PROVIDED VALIDATING THE WIND LOAD USED. 4. THE BASIC WIND SPEEDS CONSIDERED IN THIS REPORT ARE 110,120,130 MPH, EKPOSURES BAND C(BASED ON THE 2012IBC, 2015/2018IBC/IRC, 2013 CRC, AND 2016 CBC/CRC). S. FOR USE WITH THE 20121RC AND 20L3 CRC DIVIDE THE ABOVE MENTiE NNED WIND SPEEDS BY SORT D. . 1NIND SPEED (SEE NOTE 4) 11O MPH 120 MPH1 130 MPH EQUIVALENT 20121RC 12013 CRC WIND SPEED I 85 MPH I 93 MPH 1 01 MPH EXAMPLE: IF 2012 IRC OR 2013 CRC WIND SPEED 15 85 MPH, THE SELECTIONS IN THIS REPORT SHALL BE MADE FORA WIND SPEED OF 85 MPH / SQRT(0.6) =110 MPH. SNOW LOADS DESIGN PARAMETERS: IT IS THE RESPONSIBILITY OF THE ENTITY SUBMITTING THE DRAWINGS FOR THIS PROD ECF TO VERIFY SNOW LOADS WITH THE LOCAL AUTHORITY HAVING JURISDICTION. SEE SHEETS L2.1 AND L2.2 OR L2.1 AND L2.2 FOR SNOW LOADS DESIGN PARAMETERS. SEISMIC LOAD DESIGN PARAMETERS: SEISMIC DESIGN BASE SHEAR:17 POUNDS PER LINEAR FOOT ALONGTHE SUPPORTING BEAMS, CONSIDERINGA 24'-0" MAXSPAN BETWEEN BEAMS AND THE FOLLOWING DESIGN PARAMETERS: 1. SITE CLASS: D 2. SEISMIC DESIGN CATEGORY: E 3, MAPPED SPECTRAL RESPONSE COEFFICIENTS: Ss =1.50, 51 = 0.6, Sds =1.0, Shc = D.50 4. RESPONSE MODIFICATION FACTOR, R=1.25 5. RISK CATEGORY II 6. THE PATIO COVER STRUCTURES DETAILED IN THIS SET OF PLANS ARE IN COMPLIANCE WITH ASCE 7.10 SECTION 12.8.1.3. AS A RESULT, THIS SET OF PLANS CAN BE USED AT ANY SITE WITH Ss> 1.5% CONSIDERING Ss = L50 WHEN DESIGNED PER 2012/2015/20181BC/IRCAND 2013/2D16 CBC/CAC. 7. THE PATIO COVER STRUCTURES DETAILED IN THIS SET OF PLANS ARE IN COMPLIANCE WITH ASCE 7-16 SECTION 12.8.1.3. AS A RESULT, THIS SET OF PLANS CAN BE USED ATANY SITE WITH 1.O<Sds<1.428, CONSIDERING Sds =1.0. FOR SITES WITH Sds<1.0, USE Sds. FOR SITES WITH Sds>1.428, IT IS ACCEPTABLE TO REDUCE THE SEISMIC LOADS USING 0.7 Sds INSTEAD OF Sds. B. MINIMUM STRUCTURAL SEISMIC SEPARATION BETWEEN EXISTING BUILDING AND FREESTANDING PATIO COVER SHALL BE 4" AT 10' HIGH MAX PATIO COVERS AND 5"AT12' HIGH MAX PATIO COVER. REFER TO STATE AND CITY CODES FOR OTHER SPACING REQUIREMENTS THAT MAY BE MORE STRINGENT. OTHER DESIGN PARAMETERS: 1. DESIGN LOADS COMBINATIONS ARE IN ACCORDANCE WITH IBC AND CBC SECTION 1605.3.1 OR 1605.3.2. 2. ALLAPPUCABLE REDUCTION FACTORS DETAILED IN THIS REPORT ARE CUMULATIVE 3. SOLID AND LATTICE ALUMINUM COVERS ARE CLASS A ROOF A55EMBLY IN ACCORDANCE WITH SECTION CBC 1505.2, EXCEPTION 2. DESIGN ASSUMPTIONS: 1. MINIMUM ROOF SLOPE FOR SOLID ROOF PANELS WITH DECK: SEE DETAIL 1B/53.2 2. MINIMUM ROOF SLOPE FOR SOLID ROOF PANELS WITH DURAPANEL: SEE DETAILIA/S3.2 3. MAXIMUM ROOF SLOPE FOR ALL STRUCTURES IS 3 DEGREES 4. THE "LENGTH OF STRUCTURE" SHALL BE TAKEN AS THE CONTINUOUS DISTANCE MEASURED ALONG THE EXISTING BUILDING WALL FROM ONE END OF PATIO COVER SUPPORT BEAM TO THE OTHER, INCLUDING ANY BEAM SPLICES. THE STRUCTURE LENGTH SHALL BE DETERMINED THIS WAY REGARDLESS OF ROOF COVERING TYPE, INCLUDING COMBINATION ROOFS WITH BOTH TRELLIS AND DECK ROOF USED ON THE SAME CONTINUOUS PATIO COVER STRUCTURE, HOWEVER, PORTIONS OF THE STRUCTURE DESIGNED AS LATTICE COVER SHALL NOT BE COVERED BY ROOF DECK., S. CALCULATIONS FOR MAXIMUM SPANS WHEN ATTACHING TO AN EXISTING ROOF OVERHANG, AS SHOWN ON TABLE ION56.LAND/OR LEA, ARE ASSUMING THAT THE EXISITNG WOOD RAFTERS OR TRUSSES ARE DOUGLAS FIR -LARCH Not. THIS TABLE CAN ALSO BE USED FOR OTHER WOOD SPECIES WITH Fb>_ 900 psi AND Fv 2180 psi. BY: DURALUM PRODUCTS, IN . GENERAL NOTES DRAWING NOTES: 1. THE DRAWINGS AND SPECIFICATIONS SHOWN REPRESENT THE FINISHED STRUCTURE, UNLESS OTHERWISE NOTED, AND DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL SUPERVISE AND DIRECTTHEVYORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. 2. THE APPROVED SET OF DRAWINGS AND SPECIFICATIONS SHALL BE KEPT AT THE JOB SITE AND SHALL BE AVAILABLE TO THE AUTHORIZED REPRESENTATIVES OF THE BUILDING AND SAFETY DEPARTMENT. THERE SHALL BE NO DEVIATION FROM THE APPROVED PLANS AND SPECIFICATIONS WITHOUT AN APPROVED CHANGE ORDER. MATERIAL SPECIFICAJY ONS: 1. ALUMINUM ALLOYS SPECIFIED ON DRAWINGS. Fty=2BKSIAND Ftu=35KSIFOR ALL ALUMINUM MEMBERS UNO.Fty=30KSIFOR DURAKINGAND T6PANS SHOWN ON53.3.ALTERNATE ALUMINUM ALLOYS MAYBE SUBSTITUTED FOR THOSE SHOWN, PROVIDED THEY ARE REGISTERED WITH THE ALUMINUM ASSOCIATION, ASTM OR EN (EUROPEAN STANDARDS), AND HAVE EQUAL OR GREATER YIELD AND ULTIMATE STRENGTHS. 2. CONCRETE SHALL HAVE MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 2,500 POUNDS PER SQUARE INCH. 3. EMBEDDED S'IEEL MEMBERS SHALL BEHOT-DIPPED GALVANIZED, AND CONFORM TO A500 GRADE B. ROLL FORMED STEEL MEMBERS SHALL CONFORM TO A653-SS (STRUCTURAL STEEL) GRADE 50 GISO. 4. BOLTS: ALUMINUM BOLTS SHALL BE 202444; STEEL BOLTS SHALL BE ASTIA A-307. ALL BOLTS SHALL HAVE STANDARD -CUT PLATED WASHERS. S. SCREWS: ALL ';CREWS ARE SELF DIRILUNG (SDS) OR SHEET METAL SCREWS ISMS) IN CONFORMANCE WITH ICC-ES ESR 1976, IOC-ESR 3005, OR APPROVED EQUAL 6. FASTENERS T� I WOOD: WOOD AND LAG SCREWS ARE REQUIRED TO BE INSTALLED IN ACCORDANCE WITH THE 2015 NATIONAL DESIGN SPECIFICATIONS, INCLUDING PRE -DRILLING OF HOLES. ALL LAG SCREWS SHALL BE FUL: THREADED LAG SCREWS. 7. POST -INSTALLED ANCHORS: POST -INSTALLED ANCHORS USED SHALL BESIMPSONSTRONG TIE STRONG BOLT 2,STAINLESS STEEL (IOC-ESR3037) OR EQUAL BOLTS SHALL BE INSTALLED PERTHE MANUFACTU;ER'S INSTALLATION AND IAPMO REPORT. SPECIAL INSPECTION 15 NOT REQUIRED. B. ALL COMPON ENTS MANUFACTURED OR SUPPLIED BY DURALU M AND DESCRI BED IN THIS DOCUMENTS ARE INTERCHANGEABLE, PROVIDED THEY ARE SELECTED APPROPRIATELY TO SUPPORT THE LOADING THEY ARE SU'.ECTTO. 9. THE SELF WE GHT OFTKE PATIO COVER COMPONENTS IN THIS REPORT CAN BE CALCULATED FROM THEIR SECTION PROPERTIES. THE SOUD COVERS VARY IN WEIGHT FROM ABOUT I PSF TO ABOUT 3 PSF. 10. ROOF INSULb TIED PANELS (WHERE OCCURS). SEE S3.2 AND IAPM0505. FOOTINGS: 1. ALL NEW CO!)'CRETE FOOTINGS SHALL BEAR ON FIRM, NATURAL, UNDISTURBED 501LOR CERTIFIED FILL 2. DESIGN VERI,CALSOIL BEARING PRESSURE IS 1,500 POUNDS PER SQUARE FOOT. 3. DESIGN LATE 'AL SOIL BEARING PRESSURE IS 200 POUNDS PER SQUARE FOOT PER FOOT OF FOOTING DEPTH. (EQUALS 100 PSF/FTx2 PERTABLE 1906.2 AND SECTION 1806.3.4), 4. THE BOTTOf OF FOOTINGS SHALL EXTEND BELOW THE FROST DEPTH. CONTRACTOR TO VERIFY FROST DEPTH WITH AUTHORITY HAVING JURISDICTION. SLAB ON GRADE USI ) AS A, FOUNDATION SYSTEM; IN ACCORDANCEWHIRC CRC APPENDIXH SECTI0NAH105.2 AND IB /IRC APPENDIX 1, SECTION I105.Z IN AREAS WITH AFROST DEPTH EQUAL TOZERO, ATTACH ED TO AN EXISTING CO' CRETIE SLAB PROVIDED TrIE FOLLOWING: 1. THE SLAB 01, GRADE ISAT LEAST 3 1/2 INCHES THICK. SEE DETAIL 3 ON 57.2 OR L7.2 AND DIETAIL4 ON S7.1 OR L7.1 FOR REQUIREMENTS FOR THICKER SLAB. 2. THE SLAB 0!: GRADE SHALL BE CONTINUOUS BETWEEN COLUMNS AND A MINIMUM OF 1O'-O" WIDE. WITHIN THIS AREA, THERE SHALL BE NO CRACKS WIDER THAN 1/4" OR CONTROL/EXPANSION JOINT DEEPER/WII ;R THAN 3/4". 3. THERE SHAL BEA 6' MINIMUM DISTANCE BETWEEN ANY ANCHOR BOLT AND A SLAB EDGE, CRACK WIDER THAN 1/32- OR CONTROLIEXPANSION JOINT DEEPER THAN 2/2".SEE DETAIL54ON57.1ORL7.IFOR EXCEPTION'•0 MINIMUM EDGE DISTANCE. 4. THE MAXIM RJI DEAD AND UVE / SNOW LOAD AT EACH COLUMN IS 750 POUNDS WHEN LL=IOPSF. 5. DESIGN FOR lATIO COVERS SUPPORTED ON CONCRETE SLAB ON GRADE 15 IN ACCORDANCE WITH 2O12/2015/2018 IRCAND 2013/2015 CRCSECTIC)N AH105.2 FORM PSF RESIDENTIAL CONSTRUCTION, AND ACI 318-14 F?R 20, 25 AND 30 PSF RESIDENTIAL AND COMMERCIAL CONSTRUCTION. NOTES TO LOCAL AUTHORITY HAVING JURISDICTION AND ENTITY SUBMITTING DRAWINGS FOR APPROVAL USE OF TH IS SET OF MANS FORA SITE SPECIFIC PROJECT: 1. NOTALLPA(,ESOFTHISIAPMO REPORTWILLBEUSED FOR A51TESPECIFIC PROJECT. EACH PROJECT SUBMITTED TOTHE LOCALAUTHORITYHAVING JURISDICTION SHOULD INCLUDEONLY THE PERTINI NT STTUSPECIFIC STRUCTURAL COMPONENTS LOCATED WITHIN THIS IAPMO-LISTED EVALUATION REPORT. 2. ALL ITEMS NIRTAINING TO EACH INSTALLATION (TYPE OF ROOF PANEL, HEADER SPAN, COLUMN SIZE, CONNECTION DETAILS ETC.) SHALL BE CIRCLED AND CLEARLY IDENTIFIED BYTHE ENTITY SUBMITTINGTHE DRAWINGS FOR APPROVAL 3. PLEASE NO-c THAT45TEL ENGINEERING GENERATED ANDSTAMPED THE ORIGINAL IAPMO REPORT AS AVAILABLE FROM IAPMO DIRECTLY, BUT WAS NOT INVOLVED IN MAKING ANY SITE SPECIFIC SE! ECTION5 OR ANOTATIONS ON THOSE DRAWINGS. ANY HANDMARKING OR HIGHLIGHTING ON THE SITE SPEGFICSET OF DRAWINGS ARE THE RESPONSIBILITY OF THE ENTITY SUBMITTIN iTHE DRAWINGS FOR APPROVAL 4. EACH INSTAI-LATION SHALL BEAR AN IDENTIFYINGTAG INDICATINGTHE NAME ANDADDRESSOFTHE MANUFACTURER DESIGN LOADSAND ENCLOSABILFTY. 5, THE ORIGINAL APMO REPORT BEARS AN ELIECTRONICSTAMP FROM 4STEL ENGINEERING, AND AWETSTAMP IS NOT REQUIRED IN ACCORDANCE WITH THE REGULATIONS STATED BYTHE PROFESSIOIRAL BOARD OF ENGINEERS. 6. A COLOR CLPY OF THE ORIGINAL PAGES FROM THE IAPMO REPORT 15 NOT REQUIRED. A COLOR COPY OFTHE CONSTRUCTION DOCUMENTS MAYBE REQUIRED IF SELECTIONS WERE MADE _ IN A WAY TI IAT WILL NOT BE VISIBLE ON A BLACK AND WHITE COPY ATAMWIMUM. SL'3MISSION FORA BUILDING PERMIT MUST 114CLUDE THE FOLLOWING INFORMATION FROM THIS EVALUATION REPORT: 17JTLE SHEe AND GENERAL NOTES SHEET, GOA 2. IAPMO APP' OVED SHEET GO.2 3. STRUCTURP . CO N FIG U RATIO N (Le. SOLID OR LATTICE ROOF, FRE ESTAN DI NG OR ATTACHED), SHEET SI.x OR L1.x 4. SN OW LOA" DESIGN SHEETS52.1AND 52.2,WHERE APPLICABLE. 5. BASED ON'HERE UIREDDESIGNLOADSSFTE-SPECIFTERANDxORL3.x Q FIC RA /OR PANELSPANTABLESS3126. TYPE OF HE%DER, POST TYPE & QUANTITY, FOOTING5IZE(WHERE REQUIRED)BASEDONTHESTTESPECIF)CDE TY QUIIVTA 7. AP PROP RIATESTRUCTURALDETAILS. 8. OTHERDO( UMENTATIONTHAT MAY BEREQUIRED BYTHE LOCAL AUTHORITY HAVINGJUR15DICTION,SUCH ASi BUILDING DIVISION 9. 5EE Sl.x OR L1.x FOR SHEET INDEX. REVIEWED FOR SHEET INDEX SEE SHEET S1.x OR L1.x FOR SHEET INDEX. ni i i wi icrn cuoerc cunt i o0 oo�nrnion omen Tuic cor no nomm�nir_c JOB NAME: JOB ADDRESS: \ 7- La , 'c4 U 10 Q lzr -• WIND LOAD: LIVE I SNOW LOAD: CODE COMPLIANCE DATE BY 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 FESS ff S 58 5 .rF OF CA1-�FC� DATE SIGNED: July 8, 2019 vmNym _ 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 TAP M� ES OTM EXPIRES ON: JUNE 30, 2020 REVISIONS MARK DATE DESCRIPTION 4 STEL JOB # DA02-02 DATE 07108/19 DRAWN BY RC CHECKED MDS IAPMO 195 V 3.1.1 TITLE SHEET, DESIGN LOADS, GENERALNOTES GO. 1 0 O N l _ L PATIO COVER SYSTEM AS MFG. BY: DURALUM PRODUCTS, INC. I �Es EVALUATION1 7 195 Originally Issued: OSTO112011 Revised: 0711612012 Valid Through: 0613D2020 DURALUM PRODUCTS, INC. 2485 Railroad Street Corona, California 92880 (951)7364500 x.du realu nt.vo rl RESIDENTIAL PATIO COVERSi CARPORTS, AND COMMERCIAL ROOF STRUCTURES CSI Sec ima; 10 73 00 Prulccdvc Covers 13 34 00 Fabricated Eogiueered Structures 1.6 RECOGNITION 1.t Pete Cove- Dunham Produce Rcridenrial fain Stovers ncognimil in this report hart been natlaicd for use for semvidii m L ouldoor living purposes associated with da2lling unit and not a rvpnni, gamges, bloc 6'• rooms or habiuble rooms. The Residential Patio Covers comply with Apprudix I or she IBC and CBC, and Appendix H of she IRC and CRC. 1.1 di*rts nod Commercial Itunf Stuctures: Durshum Produce Carport; and Commcreinl Roof Structures mcognircd in this report lave been evaluated foruse wizen peru nal by the appl ictlue chsprrrc of the IBC, including Sections 406 and 1105, Carport associmed rich ono and iwo-fml ly dnrl I ing units art fr use where permitted by the IRCw CM including Section R309. 1.3 Compilaarr. The alrucltsal proper!in of she R"nio ial P-si. Covert, Carpnnr, and Cam,mielal Runr Situelueei recognited in this report were nelusted for compliance with lire fllowing cudesuud rcgulati¢m; e 2011� 2015 and 2012 International Building Coda' (1BC) • 2018, 2015 and 2012 Imemuto..I Residential Code - UK) e 2016and2013 California Building Code(CBC) • 2016•.,12013 Califomia Residential Code` (CRC) • ASCE 7-16 and 7-10 - Minimum Design Load, for Buildings and Ocher Simcrurts • ADM 1.2015- Aluminum Design Mutual Pant 2.0 LJM1f4kn0WS Use of the Dumlum Producs Residential Patio Ctivers. Corpons, and Commercial A"I'Strwisrrvs Menge fired in this mpori and deWiled Tn the abashed pions a ndspeei fialiom Rnision V3.1.1 signed and dined duly B. 2019. Is "abject in the following Iimitm mar, Ll Cennitelion of the rrshdemlal patio eevrrs, eafpens end cnnroumriul runt-1mclraea shall comply wish the appl irablc nodes_ manor tmer'x huullalluu imwnlous, this repot and the acrnuVanying plops, baring the name Dumlum Products, Inc, and 4STEL Engineering. where counicts %r ' the mere rrrrictive Awil;o 2.2 Palo cbvm 013 be aimcioled with rice- a£ rwa-farakly dwelling vi%4 only and shale) be limited re, u,e a, srivctarn regulated under Appendix I of the IBC or CBC or Appendix I l of at, IRC or CAC 23 Carpets end emmmerciol roof stnstrums shag be limited to trseas rnuntrrr repvlaird by the applicable chaylrrs or" IBC for Risk Catr6.vry 11 in -cook= uilk Tabk IS -I of ASCE 7. Cagvvis eaarialcel wide tax- and 1w f oily dfxxling units shall be Kpiitcd la use at ssrudmrs icguslcd by the oppi!cable chapters of The IBC, IRC, CDC and CRC 2A Cnmuunion dacumcnu subm)%-d to the buildio; ollikial for app.,•I .1m1l inuNtie this "clot and the bile-xpmll'k; WWUM' cm7`i`tcros of the nccomgra"n•ing plenr, 40u limg bud tar Umhed m 11,e lido sheet ccnerul notes, oppkicklic code- Fimcsural rnnfigmtion, cl -kgn erileria in Secima 3.1 of tth repot, rclalcd span ImblM uer, pod and folxkng types. and appmprisle xutetund dowils. 74 The existing slrucruc shall be adequate to suppuri the additional loads imposed by the allached patio cover. 2.6 Fur patio corm. tarpons and communal roof drpriwes mubicel to snow 041-wing and slidinc, tabulmird spares shall be modified in aecardarrce with the reduction factors shown in the accompanying plans- 2-7 Thr pmjcction over Ieageh ratio ofnliecle:J pit In meera shall not exceed n5 •,ilea using design for Attached pedo entu. and can Ire inueusnl to 4A wlh siting column and foot ing sires for ke4anding strums The pmjerilm over 10jih rorio for fmutand ing cower% is nor l i ntiled, 2A Freestanding and arched patio ravers, caq,nns, end om am-1.l structures shall have o roof slope of m Icon 14 inch per fool (2.063 pereenl� 2.9 For attached patio covers wining structures shall have a minimum width of 3o feet t2.7 m), psaxkawn levo of 5o feel (36.6 m): menu roof heigld of 22 Con (6.9 m) or less in Exporurc Category B and 15 fed (4.6 m) a less in Lvposvre Category C and a roof slnpe of J3A2 to 6:12 (123 to 50 pereeno. Minimum Fire of roor-chi angs is 50 square feet raa9ew•r rw.r,�rrrw r.r.,r..r�.a�.�rr�r,�.. MnRr..M rr�.+r •a enwrv�%n.�m�wMWnwmetw W.�w,wa�H'ir•re+nnrrNrr�u�f. /•N•.Rrwwrr4 Mnrrt•�•4wlr awvMp n eheaww rpf.}R ra,aw.r e+il ffirw •>•r�v/e e•WaH wovc.•n�af-..,m,�.• rF.+.sww.awrrar.sal.hnr.....rw.ae.e. rardaa. �ta»�swr. s�nrxsn.rrr l ...,, ry•.:ss xs:n..e„e n.r ev...crs...arar,rns.use _ IAPMO APPROVAL �E8EVALUATION REPORT:.� 195 Originally Issued: 05/0112011 Revised: DVIBI2DIS Valid Through: 0613012020 2.tO I'mosianding covers attached coven and Ilk cm -ling bAlIngw ulhich caters are auaehrd shall amtply wlh the reaping requirements of (7apter 26 -!ASCE 7 Tor regular 1comavic shtpc And mspww draraererhrkrL 2.11 %fraimum design roar live load is 10 pa147.88 Pa) for pplio eorera usociamd with a one- and two-family dwelling it and 20 psf (95.76 Pal f-carports and commercial or sinremrer. 2.12 Iiiiulafl n of loom-p]salicaare MI'panele shall be in iccerdance with its evalun tion report. Section 4.2.4 of this report and provide equivulrnr venial and lateral load caMaoily w shuwm in this report. 2.13 mvxd sealant or cout0 shall App AC i a be used at any penetrations etude in the existng wcalhe resistant cxlcrior wall envelope. "A Raitlkntal patio emm eerpnrt. aoS a xarr" w Peer ssnsentres utrjcct m eaj* phis oriel, of abrupt ebangcs aoch as wind -speed-up ors hills, ridges and csrarpmenli In accordance with Seclinn 26.5.1 or ASCE 7 are outside the scope of this report. 2-15 Any roof slruclme camusictedin an men wilb a flat caof- top srm'w• load grater bier 70.6 psf (3380 Pa) in Seismic Deslgn Calegadet A, R. C. D, DO, DI, D2, E or F, and not complying with Exception I of IBC or CDC Section 1613.11 a outride the scope of this report. 116 Addition of esttksure walls to rr-salential pally covers AWI be in acconlaski: vNtb Section 4,1 ofrhis report. 2.17 'Ibe Duralum Prod" Aaidcmial Pmlo Cnrm Carports, and Commercial Roof Structures are produced in Corona. California and Sacramento, Califomia. 3.0 PRODUCT USE j3cdgn and uulu!!elianofshc Orsnhrm Productx Residtnrly3 Pala Coven, Curpana, and Camrmrreisl Roof Suverures slag cun(dy vt•idi the epplicphic codes. the miauf�rnvcft krtrallvian fnssiunians. 11rie reppn end Ilse lueum+lnnying plans and speeifiratioru Rnision VS.I.f, sigud and dated July' g, 201g. All anoueble Iasdug eoadlai rrs abali he as L%Wcd in don plant are unyina this report )%,hero eonilku ocrur. she more ralrle"Ivc shall govrsa 3.1 D-Igm Seim ion of oppliahk rtrucuiral ".T-enu for fbe lttgallutiun of frmimdlug and anochcd resldrmiA Patio covers, c4rpore and comnkreial soof Arvnmu iku11 be in amerdiwee nilh the de Liar crise:ia - speei nc4 In the pplanx aeeoWAn)ing this rtlfmr- TIu project location. use (psuo cover, Carpon, eummemial atntdusc} co,rupondng code, and apple cable design criteria, including risk catceary OBC only}, wind speed wind expomom r rgory, roof live low. pound nsow load- stisrole design rateymry, oral 0rz7 line depth Aill be pi" oar os be ratached to Ibe pram srrompanying this repud and he observed in4,c mkeiaa eardicCampmrmi 32 Inticnsllooi rwtffaiiwl of the innfpoorntx doetanIned in Strctiw 3.1 of Ih7. repnn a condnrci the patio ca%>cr, curpom or commercial roof snucture shall be in umrdance tv4h this meant, the plum accmmp.nylnp; udc n•port, mkamfanlan's fniisliation imarattimn, erah the applicahk soda nS " report Where wnnicts on . the rrxye resuiedve shall gowns 4.0 PRODUCT DFSCRTPTI ON 4.1 Prvdurt fsim-hralldn Dumlum Prndwtr. PoWcolM Pal to Coco tarpons- and Coatrrereial Roof Suuettrn Am (h.csrandinp and atached. nonenclo.cd -lid and Ionia rrsidrn+ial perm cnfm, arporsand commercial mofsuuerures. TheAmetmer shall be cotsnveud m urmdauce with the plans nrem+rpaaying this report and as bra cnrcd in Ibls rgrors Artae6rd patio envoy, wter rumidncd, 4a0 be eves on dare sides. Atlaebed emparts naaciaierd with one- and tma.fomilr dwrRin11 unit' shall be epee on al Tr twat sides. Frcraording puliu cortex, carports and comnutvia) roof structures drag be open on all fur sides. H!bere desk _d. enclosure well configurations used with Ibe:nrinctural component. dcscnbrd in this upon to form em'hwed attached residential patio covers shall confront to Ibr limits rxnc0 in Snlion 1103 of dhc IBC or CDC and S&niaa Ali101 of the I R C or CRC. The slrucimer shall be iced in a product nahvAtion repon from an appsrnrd source nsdel"mcd in IDC and COC Section 104.11.1 w olhm FwimWiy mcagnixcd cent Eculinn program accepted by IAMIO IMrImmn Eval owl ion Seniee. 42Mnterias 4.1,1 Alamlaem: Aluminum suvermal comb m an; roO- fmmcd e,r 01rudenl dopes of %minus Allxye and [rngree, complyLrf WM Chsphx 20 ortle MC and ASTM 8209 as spocificd in the plans xrompauying th& npen. 4.22 St"k Smolt numlim are £nrrteA from ,arious grades of Sud romplyin¢ rich ASTM A500, Crack D and ASfM A651 SS (made 513 and, Alww dcsi0nard, rich s galvankrcd raal)ag cwn)ty9ng wills 060. - flieciNd In the plant acroutparning this mrim. 4.13 FAsnnerse lexmm-ra i ncludcaluminum and suer?bobs, wood sCrow& lay stews. you Installed mcbws. self-driiling serewa and rhnl metal sercwr os sphcifled in der Pula uccan anyisg this mprrrt 4.2A Fanta-Pleule-Can Punah; Tiv lant-rescd ruins -corn uodaleh roof panets uud ria the dmdural ampmeme dumbed In this report to form fer esunchng and attached residential patio and tonwercist tutu shall be Durapme3 Sreuctural Panels foe Patio Cc, ere described and recap, need in IAPMO UL•'i CR-M. Page Z 04 3 OFsEVALUATION REPORT �- ` 195 tY Originally Issued: OW612011 Revised: 0711W2018 Valld Through: OW302020 5.0IDEI�TIFICATION Enclosures envered by ibis report shall he idenfified by a permanent decal or identifying tag That ausicl the name and address of the man' fienner(Duralum Produls. IrreJ. Fish installation s1a11 bear tar origirnl identifying died er rag bearing the IAPMO UES Mark of Conformity and she Evulwlion Rcpmr Number (ER. 195). Ektller offs following %larks nrcWonmi,y may be used, Jwws: [pp�� DES r7 or TAPMO UES £R-195 COSUBSTANTTATING DATA 6.1 Pa* complying with the ICC-ES Acccptaan Criteria fat Patio Covers (AC340)_ Apprevcd Augus1201 A 6.2 Flrpjrsc9ring alruylljWu in .naucoordance wil the 2011 201 g Code, ASCE 7-10 and 7-16 and the Aluminum Design Manual Pan 1 (2015). 63 Quality eomml to 6A Product draaingt 7.0 STATEM EAT OF RECOGNITION This evaluation ".pan describes the results of research carried out by IAPMO Uniform Dvalualion Service on Duralum Products Resideaial Patio Covers, Cwpms, and Commercial RonfSwclmo snanu6mtured in Corons and Sacramento. California, to Assess their eonfhrnhana to the codes shown in Sep(m 1-0 of this reason and docurnens the pmdnei s codification. 1Trr pmate s - produced at Incisions noted in Section 2.17 of this report under ¢ quality eomrol program wish pericalc impaction under the ,supervision nf1APM0 UE'S. Page 3 of 3 Arlea Gerber. P.E, S.E. Viec Praddem, Trehainl Operations Uniform Evaloedoa Sepia /4-2111�7A./ Richard Beek PF, CEO.MCP Vice rmlilnt6 Unlroo ml Evafaullan Sen•ice GP Run Chan; CEO, The IAPMO Group Fe! aatllhlae,l Ietraullw .bnal rile tr-Julio rryoa ple.s[ rifle 2485 RAILROAD ST, CORONA, CA 92860 951.736.4500 �A TC1.r^r 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 EXPIRES ON: JUNE 30, 2020 REVISIONS MARK I DATE DESCRIPTION 4 STEL JOB A DA02-02 DATE OT1DS119 DRAWN BY RC CHECKED MDS 1APM0195 V 3.1.1 IAPMO APPROVAL GO.2 0 m m i (E) BUILDING SOLID COVER CONNECTION I I �+ T4 BLRG SEE NOTE' 2 ' 0 H Z COL,: TYP I Y SEE NOTE A I o O Ld Or w z w SOLID COVER :CONNECTION TO BEAM SEE: NOTE I 2 a BEAM CLEAR SPAN 1. BEAM CLEAR SPAN NOTE 1 LENGTH 'L' SEE NOTE 1 r �. l P_LAN VIEW NOTES 1. PATIO LOM DIMENSIONS A SEE DESIGN ASSUMPTION NOTE 4 ON GO.1 FOR PAT10 COVERS CONSISTING OF SOLD COVERS AND LATTICE FRAMING. B. HEIGHT OF STRUCTURE 'H' (TO TOP OF COVER) SHALL NOT BE OVER 12 FT. C. BEAM OVERHANG 'OH' SHALL NOT EXCEED 25% OF BEAM'S ADJACENT CLEAR SPAN. EXCEPTION: NO OVERHANG ALLOWED AT I BEAMS CONNECTED TO SIDE OF COL. D. SOLID COVER OVERHANG 'OH' SHALL NOT EXCEED 25% OF DECK OR IRP SOLD COVER'S ADJACENT CLEAR SPAN, (OR 29 MAX. AT IRP, WHICHEVER IS LESS). E. TRIBUTARY WIDTH ARE AS SHOWN ON PLAN: -TRIG (Bext)= JrZ ADJACENT DECK CLEAR SPAN @ RIGHT + DECK OH @ LEFT •TRIB (BLDG)=J¢ ADJACENT DECK CLEAR SPAN F. THE RATIO P/L (COVER PROJECTION DIVIDED BY COVER LENGTH), NOT INCLUDING DECK OR BEAM OVERHANG, SHALL NOT BE MORE THAN 2.25 WHEN USING DESIGN FOR ATTACHED PAT10 COVERS G. THE RATIO P/L (COVER PROJECTION DIVIDED BY COVER LENGTH) CAN BE UP TO 4.0 WHEN USING COLUMN AND FOOTING SIZES AS IF THE COVER WAS FREESTANDING. 2. SOLID COVERS A SEE SHEET S3.1A AND S3.3 FOR DECK PROFILES AND MAXIMUM SPANS. B. SEE SHEET S3.2 FOR DURAPANEL INSULATED STRUCTURAL SANDWICH PANELS MAXIMUM SPANS. C. SEE SHEET S2.2 FOR REDUCTION OF SOLD COVER MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEET S3.2 FOR CONNECTION OF SOLID COVERS TO SUPPORTING BEAMS. E. SEE SHEETS S3.2, S6.1 & S6.2 FOR CONNECTION OF SOLD COVERS TO (E) BUILDING. F. MINIMUM SLOPE OF SOLD DECK COVERS TO BE PER SHEET S3.2. G. MINIMUM SLOPE OF DURAPANELS TO BE PER SHEET S3.2. SOLID ROOF PANEL SEE NOTE 5, TYP ISOMETRIC VIEW 3. BEAMS A SEE SHEETS S4.1 & S4.2 FOR BEAM PROFILES. B. SEE SHEET S4.6 FOR FAN BEAM WHERE OCCURS. C. SEE SHEETS 9/S7.2 AND S8.xx.x FOR TABLES SHOWING MAXIMUM BEAM SPANS. D. SEE SHEET S2.2 FOR REDUCTION OF BEAM MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. E. SEE SHEET S6.x FOR BEAM CONNECTIONS & DETAILS. F. SEE SHEET S5.1 FOR BEAM SPLICE DETAIL WHERE REQUIRED. 4. COLUMNS A SEE TABLE 1 ON THIS SHEET FOR MINIMUM NUMBER OF POSTS REQUIRED BASED ON COVER DIMENSIONS. B. SEE SHEET S4.3 FOR COLUMN PROFILES. C. SEE SHEETS 9/S7.2 AND SB.xx.x FOR TABLES SHOWING MAXIMUM POST SPACING. D. SEE SHEETS S6.x AND S7.x FOR POSTS CONNECTIONS & DETAILS. 5. FOUNDATIONS A SEE SHEETS S7.1 AND S7.2 FOR COLUMN CONNEC110N TO FOUNDATION. B. SEE BEAM SPAN TABLES ON SHEET SB.xx.x FOR MINIMUM FOOTING SIZE FOR PATIO COVER SUPPORTED ON CONCRETE FOOTING, BASED ON BEAM SPAN SELECTED. C. SEE S7.1 FOR ALTERNATE FOOTING SIZES. D. SEE 9/S7.2 FOR ATTACHED PATIO COVER SUPPORTED ON SLAB ON GRADE. TABLE 1 MINIMUM NUMBER OF POSTS REQUIRING ATTACHMENT PER 3/S6.3 WITH 2 x 6.5 x 0.032 SIDE PLATES (SIDE PLATE TYPE SP3) TRIG WINDSPEEDAND E)P WIDTH 1109 11DC 120Bp 1309. 130C 5' 2 2 2 3 3 6 2 3 3 3 4 T 2 3 3 3 4 IT 3 3 3 4 5 9' 3 4 4 4 5 10 3 4 4 5 6 11• 4 4 4 5 S 17 4 5 5 s 5 7 WITH 2 x 6.5 x D.042 SIDE PLATES (SIDE PLATE TYPE SP4) TRIB NO EXPOSURE WIDTH 11OB 110C 120B 120C I 13DS 130C 51 2 2 2 2 2 3 v 2 2 2 3 3 3 7 2 3 3 3 3 4 8 2 3 3 4 3 4 ;T 3 3 3 4 4 5 10 3 4 4 4 4 5 11 1 3 4 4 5 5 6 17 3 4 4 5 5 5 NOTES: 1. NUMBER OF POSTS SHOWN IN THIS TABLE IS A MINIMUM. ADD POSTS AS REQUIRED TO ENSURE THATTHE "MAX POSTS PACING (SPANY SHOWN ON SHEETS SB.xx.x IS NOT EXCEEDED. 2. THIS TABLE IS TO BE USED IN CONJUNCTION WITH DETAIL 3/S6.3 3. THIS TABLE DOES NOT APPLY IF THE SIDE PLATES ARE PROVIDED FOR AESTHETICAL PURPOSES AND THE BEAM IS CONNECTED TO THE COLUMN DIRECTLY PER 2/S6.3 OR WITH A BRACKET PER 1/S4.5 8 VS63. (� A TABLE 1 -MINIMUM NUMBER OF COL REQUIRING TOP ATTACHMENT PER 3/86r3 SHEET INDEX - SOLID PANEL STRUCTURES: TYPE A GOA -TITLE SHEET, DESIGN LOADS, GENERAL NOTES GO 2 - IAPMO APPROVAL S1 1 -SOLID PANEL STRUCTURES: TYPE A S1 5 - SOLID PANEL STRUCTURES: TRIBUTARYWIDTHS TO BEAMS S2.1 - SOLID PANEL STRUCTURES: SNOW LOAD DESIGN: NEED TO CONSIDER DRIFTAND SLIDING DESIGN 82.2 - SOLID PANEL STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION FACTORS DUE TO DRIFTAND SLIDING S3.1A -SOLID PANEL STRUCTURES: ATTACHED COVERS MAXIMUM SPANS AND MINIMUM FASTENERS S3.2 - SOLID PANEL STRUCTURES: CROSS SECTIONS S3.3 - SOLID PANEL STRUCTURES: DURAKING AND T6 PAN MAXIMUM SPANS AND MINIMUM FASTENERS S4.1 - SOLID PANEL STRUCTURES: BEAM PROFILES S4.2 - SOLID PANEL STRUCTURES: BEAM PROFILES S4.3 - SOLID PANEL STRUCTURES: COLUMN PROFILES S4.4 - SOLID PANEL STRUCTURES: MEMBERS PROFILES S4.5 - SOLID PANEL STRUCTURES: CONNECTORS S4.6 - SOLID PANEL STRUCTURES: FAN BEAM DETAILS 85.1 - SOLID PANEL STRUCTURES: SPLICE DETAILS S6.1 - SOLID PANEL STRUCTURES: ATTACHMENT TO EXISTING BUILDING S6.2 - SOLID PANEL STRUCTURES: CONNECTION DETAILS S6.3 - SOLID PANEL STRUCTURES: CONNECTION DETAILS S7.1 - SOLID PANEL STRUCTURES: FOUNDATION DETAILS S7.2 - SOLID PANEL STRUCTURES: FOUNDATION DETAILS S8.xx.x- SOLID PANEL STRUCTURES: BEAM SPANS AND FOUNDATION SIZES xx PSF LUSL, 1xO MPH G9.1 -ADDITIONAL STATE LICENSURE STAMPS SOLID PANEL STRUCTURE TYPE A: ATTACHED SINGLE SPAN WITH OPTIONAL CANTILEVER 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 CD S 58 5 � f RL,CT~ 9 � TF OF CA0F DATE SIGNED: July 8, 2019 Or` Xc�:'w 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 SAP�g 1V} o O✓✓ E S TM EXPIRES ON: JUNE 30, 2020 REVISIONS MARK DATE DESCRIPTION 4 STEL JOB R DA02-02 DATE 07/D8/19 DRAWN BY RC CHECKED MDS IAPMO 195 V 3.1.1 SOLID PANEL STRUCTURES: TYPE A S1.1 m (E) BUILDING I I I I I COL,Typ SOLID COVER CQNNEC' ON i SEE:NOTE14 I ! TO BLDG SEE NOTE 2 I _• 1 I I I! I I!! I I I f l m z 11 W I _ I d I 1 SOLID COVER CONNEgON ! TO BEAM SEE NOTE 2 I m O ¢ . W I BEAM CLEAR SPAN I. BEAM CLEAR SPAN LENGTH 'L' SEE NOTE 1 C PLAN VIEW NOTES: 1. PATIO COVER 01MENSIONS A SEE DESIGN ASSUMPTION NOTE 4 ON GO.1 FOR PATIO COVERS CONSISTING OF SOLID COVERS AND LATTICE FRAMING. B. HEIGHT OF STRUCTURE 'H' (TO TOP OF COVER) SHALL NOT BE OVER 12 FT. C. BEAM OVERHANG 'OH' SHALL NOT EXCEED 257 OF BEAM'S ADJACENT CLEAR SPAN. EXCEPTION: NO OVERHANG ALLOWED AT I BEAMS CONNECTED TO SIDE OF COL. D. SOLID COVER OVERHANG 'OH' SHALL NOT EXCEED 25% OF DECK OR IRP SOLID COVER'S ADJACENT CLEAR SPAN, (OR 24" MAX. AT IRP, WHICHEVER IS LESS). E. TRIBUTARY WIDTH ARE AS SHOWN ON PLAN: •TRIG (Bext)= J¢ ADJACENT DECK CLEAR SPAN @ RIGHT + DECK OH 0 LEFT • TRIB (Dint)= Xz ADJACENT DECK CLEAR SPAN @ RIGHT + X ADJACENT DECK CLEAR SPAN 0 LEFT •TRIB (BLDG)=J¢ ADJACENT DECK CLEAR SPAN F. THE RAT10 P/L (COVER PROJECTION DIVIDED BY COVER LENGTH), NOT INCLUDING DECK OR BEAM OVERHANG, SHALL NOT BE MORE THAN 2.25 WHEN USING DESIGN FOR ATTACHED PATIO COVERS G. THE RATIO P/L (COVER PROJECTION DIVIDED BY COVER LENGTH) CAN BE UP TO 4.0 WHEN USING COLUMN AND FOOTING SIZES AS IF THE COVER WAS FREESTANDING. 2. 50LID CDVER5 A SEE SHEET S3.1A AND S3.3 FOR DECK PROFILES AND MAXIMUM SPANS. B. SEE SHEET S3.2 FOR DURAPANEL INSULATED STRUCTURAL SANDWICH PANELS MAXIMUM SPANS. C. SEE SHEET S2.2 FOR REDUCTION OF SOLID COVER MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEET S3.2 FOR CONNECTION OF SOLID COVERS TO SUPPORTING BEAMS. E. SEE SHEETS S3.2, S6.1 AND S6.2 FOR CONNECTION OF SOLD COVERS TO (E) BUILDING. F. MINIMUM SLOPE OF SOLID DECK COVERS TO BE PER S3.2. G. MINIMUM SLOPE OF DURAPANELS TO BE PER SHEET S3.2. SOLID ROOF PANEL SEE NOTE 2----\ IL (E) E BLDG. SEE NpZE 2 SL CONCRETE FTG, SEE NOTE 5, TYP B 150ME�R1C VIEW 3. BEAMS A SEE SHEETS S4.1 & S4.2 FOR BEAM PROFILES. B. SEE SHEET S4.6 FOR FAN BEAM WHERE OCCURS. C. SEE SHEETS 9/S7.2 AND SB.xx.x FOR TABLES SHOWING MAXIMUM BEAM SPANS. D. SEE SHEET S2.2 FOR REDUCTION OF BEAM MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. E. SEE SHEET S6.x FOR BEAM CONNECTIONS & DETAILS. F. SEE SHEET S5.1 FOR BEAM SPLICE DETAIL WHERE REQUIRED. 4. COLUMNS A SEE TABLE 1 ON THIS SHEET FOR MINIMUM NUMBER OF POSTS REQUIRED BASED ON COVER DIMENSIONS. B. SEE SHEET S4.3 FOR COLUMN PROFILES. C. SEE SHEETS 9/S7.2 AND SB.xx.x FOR TABLES SHOWING MAXIMUM POST SPACING. D. SEE SHEETS S6.x AND S7.x FOR POSTS CONNECTIONS & DETAILS. �;_„FOIJ;4YQATI OtTS A SEE SHEETS S7.1 AND S7.2 FOR COLUMN CONNECTION TO FOUNDATION. B. SEE BEAM SPAN TABLES ON SHEET SB.xx.x FOR MINIMUM FOOTING SIZE FOR PATIO COVER SUPPORTED ON CONCRETE FOOTING, BASED ON BEAM SPAN SELECTED. C. SEE S7.1 FOR ALTERNATE FOOTING SIZES. D. SEE 9/S7.2 FOR ATTACHED PAT10 COVER SUPPORTED ON SLAB ON GRADE. INT. BEAM SEE NOTE 3 x EXT. BEAM SEE NOTE 3 TABLE 1 MINIMUM NUMBER OF POSTS REQUIRING ATTAr.HMFNT PFR 3MB 3 WITH 2 x 6.5x 0.032 SIDE PLATES (SIDE PLATE TYPE SP3) 1106 110C 7208 120C 1306 130C 2 2 x 3 3 3 2 3 3 3 3 4 D"la 2 3 3 4 3 4 3 3 4 4 5 4 4 4 4 5 3 4 4 5 5 6 1'Y 4 4 4 5 5 8 12' 4 5 5 6 5 7 WfiH 2x C5x"0.042 SIDE PLATES' - (SIDE PLATE TYPE SP4) TRIG D N OPOSURE WIDTH 110E 110C 1205 120C 1306 130C 5' 2 2 2 2 2 3 E 2 2 2 3 3 3 7' 2 3 3 3 3 4 6' 2 3 3 4 3 4 9' 3 3 $ 4 4 5 10 3 4 4 4 4 5 11' 3 4 4 5 5 6 12 3 4 4 Is5 5 NOTES: 1. NUMBER OF POSTS SHOWN IN THIS TABLE IS A MINIMUM. ADD POSTS AS REQUIRED TO ENSURE THATTHE "MAX POST SPACING CONCRETE SLAB, (SPAN)" SHOWN ON SHEETS SB.xx.x IS NOT EXCEEDED. SEE NOTE 5 2. THIS TABLE IS TO BE USED IN CONJUNCTION WITH DETAIL 3/S6.3 3. THIS TABLE DOES NOTAPPLY IF THE SIDE PLATES ARE PROVIDED FOR AESTHETICAL PURPOSES AND THE BEAM IS CONNECTED TO THE COLUMN DIRECTLY PER 2/S6.3OR WITH A BRACKET PER VS4.5 & 1/S6.3. (�'�YTAILIE�l - MINIMUM NUMBER OF COL EQUIING TOP ATTACHMENT PER 3/3&3 SHr.FT INDEX -SOLID PANEL STRUCTURES: TYPE B GOA -TITLE SHEET, DESIGN LOADS, GENERAL NOTES GO.2 - IAPMO APPROVAL S1.2-SOLID PANEL STRUCTURES: TYPE B S1.5 -SOLID PANEL STRUCTURES: TRIBUTARYWDTHIS TO BEAMS S2.1 -SOLID PANEL STRUCTURES: SNOW LOAD DESIGN: NEED TO CONSIDER DRIFTAND SLIDING DESIGN S2.2 -SOLID PANEL STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION FACTORS DUETO DRIFTAND SLIDING S3.1 A - SOLID PANEL STRUCTURES: ATTACHED COVERS MAXIMUM SPANS AND MINIMUM FASTENERS S3.2 -SOLID PANEL STRUCTURES: CROSS SECTIONS S3.3 - SOLID PANEL STRUCTURES: DURAKING AND T6 PAN MAXIMUM SPANS AND MINIMUM FASTENERS S4.1 -SOLID PANEL STRUCTURES: BEAM PROFILES S4.2 -SOLID PANEL STRUCTURES: BEAM PROFILES S4.3 - SOLID PANEL STRUCTURES: COLUMN PROFILES S4.4-SOLID PANEL STRUCTURES: MEMBERS PROFILES S4.5-SOLID PANEL STRUCTURES: CONNECTORS S4.6 -SOLID PANEL STRUCTURES: FAN BEAM DETAILS S5.1 -SOLID PANEL STRUCTURES: SPLICE DETAILS S6.1 -SOLID PANEL STRUCTURES: ATTACHMENT TO EXISTING BUILDING S6.2-SOLID PANEL STRUCTURES: CONNECTION DETAILS S6.3 -SOLID PANEL STRUCTURES: CONNECTION DETAILS S7.1 -SOLID PANEL STRUCTURES: FOUNDATION DETAILS S7.2 -SOLID PANEL STRUCTURES: FOUNDATION DETALS SB.xxx-SOLID PANEL STRUCTURES: BEAM SPANS AND FOUNDATION SIZES xx PSF LLISL, 1x0 MPH G9.1 -ADDITIONAL STATE LICENSURE STAMPS SOLID PANEL STRUCTURE TYPE B: ATTACHED MULTI -SPAN WITH OPTIONAL CANTILEVER olw 6 - ZSOU6 COVER CONNECTION w d I ITO BEAM- SEE NOTE 2' w w w ZEn w cn w 0 U Z I ]e o O w 8 COL, :TYP z w w N SEE NOTE 4 a I[ r r BEAM OH BEAM CLEAR SPAN SEE NOTE 1 LENGTH 'L' SEE NOTE 1 a 9EAA1 OH SEE NOTE 1 PLAN viFw V NOTES: 1. PAPQ COVER DIMENSIONS A SEE DESIGN ASSUMPTION 4 ON GO.1 FOR PATIO COVERS CONSISTING OF SOUD COVERS AND LATTICE FRAMING. B. HEIGHT OF STRUCTURE 'H' (TO TOP OF COVER) SHALL NOT BE OVER 12 FT. C. BEAM OVERHANG 'OH' SHALL NOT EXCEED 25% OF BEAM'S ADJACENT CLEAR SPAN. EXCEPTION: NO OVERHANG ALLOWED AT I BEAMS CONNECTED TO SIDE OF COL D. SOUD COVER OVERHANG 'OH' SHALL NOT EXCEED 25% OF DECK OR IRP SOUD COVER'S ADJACENT CLEAR SPAN, (OR 24" MAX. AT IRP, WHICHEVER IS LESS). E. TRIBUTARY WIDTH ARE AS SHOWN ON PLAN! ° TRIB (Bext)= kz ADJACENT DECK CLEAR SPAN @ RIGHT + DECK OH @ LEFT 2. A SEE SHEET S3.1F AND S3.3 FOR DECK PROFILES AND MAXIMUM SPANS. S. SEE SHEET S3.2 FOR DURAPANEL INSULATED STRUCTURAL SANDWICH PANELS MAXIMUM SPANS. C. SEE SHEET S2.2 FOR REDUCTION OF SOUD COVER MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEET S3.2 FOR CONNECTION OF SOLID COVERS TO SUPPORTING BEAMS. E. SEE SHEETS S3.2, S6.1 AND S6.2 FOR CONNECTION OF SOLID COVERS TO (E) BUILDING. F. MINIMUM SLOPE OF SOLID DECK COVERS TO BE PER SHEET S3.2. G. MINIMUM SLOPE OF DURAPANELS TO BE PER SHEET S3.2. SEE NOTE 5, TYP 9 ISOMETRIC VIEW 3. BEAMS A. SEE SHEETS S4.1 & S4.2 FOR BEAM PROFILES. B. SEE SHEET S4.6 FOR FAN BEAM WHERE OCCURS. C. SEE SHEETS 9/S7.2 AND S8.xx.x FOR TABLES SHOWING MAXIMUM BEAM SPANS. D. SEE SHEET S2.2 FOR REDUCTION OF BEAM MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. E. SEE SHEET S6.x FOR BEAM CONNECTIONS & DETAILS. F. SEE SHEET S5.1 FOR BEAM SPUCE DETAIL WHERE REQUIRED. 4. COLUMNS A SEE TABLE 1 ON THIS SHEET FOR MINIMUM NUMBER OF POSTS REQUIRED BASED ON COVER DIMENSIONS. B. SEE SHEET S4.3 FOR COLUMN PROFILES. C. SEE SHEETS 9/S7.2 AND SS.xx.x FOR TABLES SHOWING MAXIMUM POST SPACING. D. SEE SHEETS S6.x AND S7.x FOR POSTS CONNECTIONS & DETAILS. 5. LO-IJ [lA, ;10tiS A. SEE SHEETS S7.1 AND S7.2 FOR COLUMN CONNECTION TO FOUNDATION. B. SEE BEAM SPAN TABLES ON SHEET SS.xx.x FOR MINIMUM FOOTING SIZE FOR PAT10 COVER SUPPORTED ON CONCRETE FOOTING, BASED ON BEAM SPAN SELECTED. C. SEE S7.1 FOR ALTERNATE FOOTING SIZES. TABLE 1 MINIMUM NUMBER OF POSTS REQUIRING ATTACHMENT PER3IS6.3 WITH 2 x 6.5 x 0.032 SIDE PLATES (SIDE PLATE TYPE SP3) TRIB VV INDAR WIDTH 1109 11DC 120E 12OG 1309 130C 5 2 2 2 3 3 3 B 2 3 3 3 3 4 7 2 3 3 4 3 4 8 3 3 3 4 4 5 91 3 4 4 4 4 5 10 3 4 4 5 5 6 11' 4 4 4 5 5 B 12, 4 5 5 6 5 7 WITH 2 x 6.5 x 0.042 SIDE PLATES (SIDE PLATE TYPE SP4) TRIG WIDTH WIND SPEEDAND E)FOSURE 1106 110C 12D9 12DC 1306 130C V 2 2 2 2 2 3 5 2 2 2 3 3 3 7 2 3 3 3 3 4 67 2 3 3 4 3 4 9 3 3 3 4 4 5 10' 3 4 4 4 4 5 11' 3 4 4 5 5 6 12 3 4 1 4 5 F 5 5 NOTES: 1. NUMBER OF POSTS SHOWN IN THIS TABLE IS A MINIMUM. ADD POSTS AS REQUIRED TO ENSURE THATTHE'MAX POST SPACING (SPAN)°SHOWN ON SHEETS S8.xx.x IS NOT EXCEEDED. 2. THIS TABLE IS TO BE USED IN CONJUNCTION WITH DETAIL 3/S6.3 3. THIS TABLE DOES NOTAPPLY IF THE SIDE PLATES ARE PROVIDED FOR AESTHETICAL PURPOSES AND THE BEAM IS CONNECTED TO THE COLUMN DIRECTLY PER 2/SS.3 OR WITH A BRACKET PER 1/S4.5 & 1/S6.3. �TABLEMINIMUMNUMBlwR OF COL"G TOP ATTACHMENT PER 3/S6.3 SHEET INDEX - SOLID PANEL STRUCTURES: TYPE C G0.1 -TITLE SHEET, DESIGN LOADS, GENERAL NOTES G0.2 - IAPMO APPROVAL S1.3 - SOLID PANEL STRUCTURES: TYPE C S1.5 - SOLID PANEL STRUCTURES: TRIBUTARY WIDTHS TO BEAMS S2.1 - SOLID PANEL STRUCTURES: SNOW LOAD DESIGN: NEED TO CONSIDER DRIFTAND SLIDING DESIGN S2.2-SOLID PANEL STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION FACTORS DUE TO DRIFT AND SLIDING S3.1 F - SOLID PANEL STRUCTURES: FREESTANDING COVERS MAXIMUM SPANS AND MINIMUM FASTENERS S3.2-SOLID PANEL STRUCTURES: CROSS SECTIONS S3.3 - SOLID PANEL STRUCTURES: DURAKING AND T6 PAN MAXIMUM SPANS AND MINIMUM FASTENERS S4.1 -SOLID PANEL STRUCTURES: BEAM PROFILES S4.2 - SOLID PANEL STRUCTURES: BEAM PROFILES S4.3 - SOLID PANEL STRUCTURES: COLUMN PROFILES S4.4 - SOLID PANEL STRUCTURES: MEMBERS PROFILES S4.5-SOLID PANEL STRUCTURES: CONNECTORS S4.6 - SOLID PANEL STRUCTURES: FAN BEAM DETAILS S5.1 - SOLID PANEL STRUCTURES: SPLICE DETAILS S6.1 - SOLID PANEL STRUCTURES: ATTACHMENT TO EXISTING BUILDING 86.2- SOLID PANEL STRUCTURES: CONNECTION DETAILS S6.3 - SOLID PANEL STRUCTURES: CONNECTION DETAILS S7.1 - SOLID PANEL STRUCTURES: FOUNDATION DETAILS S7.2 - SOLID PANEL STRUCTURES: FOUNDATION DETAILS SB.xx.x- SOLID PANEL STRUCTURES: BEAM SPANS AND FOUNDATION SIZES xx PSF LUSL, 1x0 MPH G9.1 -ADDITIONAL STATE LICENSURE STAMPS SOLID PANEL STRUCTURE TYPE C: FREESTANDING SINGLE SPAN WITH OPTIONAL CANTILEVER 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 S 58 5 qr� OF CA0 DATE SIGNED: July 8, 2019 �J 7 i0f_ 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 SAP IYf o ES TM EXPIRES ON: JUNE 30, 2020 REVISIONS MARK DATE DESCRIPTION 4 STEL JOB # DA02-02 DATE 0710B/19 DRAWN BY RC CHECKED MDS IAPMO 195 V 3.1.1 SOLID PANEL STRUCTURES: TYPE C S1.3 X m m m i c m m d m Ln w I SOLID ,COVER CONNECTON I E `� TO BEM(. SEE NOTE 2 ' COL iYi? - + - - --SEE-NOTE- 4-' QJ l V I I I U ,lj O _ i ! 1 c u' I ' z o v'i o Lu E N I I { I I f BEAM CLEAR SPAN I. BEAM LENGTH 'L' SEE NOTE 1 C PLAN YfE1N NOTES: 1. PATIO COVER DIMENSIONS A SEE DESIGN ASSUMPTION 4 ON GO.1 FOR PATIO COVERS CONSISTING OF SOLID COVERS AND LATTICE FRAMING. B. HEIGHT OF STRUCTURE 'H' (TO TOP OF COVER) SHALL NOT BE OVER 12 FT. C. BEAM OVERHANG 'OH' SHALL NOT EXCEED 25% OF BEAM'S ADJACENT CLEAR SPAN. EXCEPTION: NO OVERHANG ALLOWED AT I BEAMS CONNECTED TO SIDE OF COL D. SOLID COVER OVERHANG 'OH' SHALL NOT EXCEED 25% OF DECK OR IRP SOLID COVER'S ADJACENT CLEAR SPAN, (OR 24" MAX. AT IRP, WHICHEVER IS LESS). E. TRIBUTARY WIDTH ARE AS SHOWN ON PLAN: •TRIB (Bext)= 14 ADJACENT DECK CLEAR SPAN @ RIGHT + DECK OH @ LEFT • TRIB (Sint)= h ADJACENT DECK CLEAR SPAN @ RIGHT + h ADJACENT DECK CLEAR SPAN @ LEFT A SEE SHEET S3.1F AND 53.3 FOR DECK PROFILES AND MAXIMUM SPANS. B. SEE SHEET 53.2 FOR DURAPANEL INSULATED STRUCTURAL SANDWICH PANELS MAXIMUM SPANS. C. SEE SHEET S2.2 FOR REDUCTION OF SOLID COVER MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. D. SEE SHEET S3.2 FOR CONNECTION OF SOLID COVERS TO SUPPORTING BEAMS. E SEE SHEETS 53.2, 56.1 & 56.2 FOR CONNECTION OF SOLID COVERS TO (E) BUILDING. F. MINIMUM SLOPE OF SOLID DECK COVERS TO BE PER SHEET 53.2. G. MINIMUM SLOPE OF DURAPANELS TO BE PER SHEET 53.2. SCUD ROOF PANEL SEE NOTE 2 EXT. BEAM Nog 2 SEE NOTE 3 SLOPk� INT. BEAM SEE NOTE 3 - Z w N uj ' � �L-CONCRfT£ SLAB, CONCRETE FTG, SEE NOTE 5 SEE NOTE 5, TYP n ISOMETRIC VIEW a 3. BEAMS A. SEE SHEETS S4.1 & 54.2 FOR BEAM PROFILES. B. SEE SHEEP 54.6 FOR FAN BEAM WHERE OCCURS. C. SEE SHEETS 9/S7.2 AND SB.xx.x FOR TABLES SHOWING MAXIMUM BEAM SPANS. D. SEE SHEET 52.2 FOR REDUCTION OF BEAM MAXIMUM SPAN WHEN DESIGNING FOR SNOW LOADS. E SEE SHEET S6.x FOR BEAM CONNECTIONS & DETAILS. F. SEE SHEET 55.1 FOR BEAM SPLICE DETAIL WHERE REQUIRED. 4 col-UMNS A. SEE TABLE 1 ON THIS SHEET FOR MINIMUM NUMBER OF POSTS REQUIRED BASED ON COVER DIMENSIONS. B. SEE SHEET 54.3 FOR COLUMN PROFILES. C. SEE SHEETS 9/57.2 AND SB.xx.x FOR TABLES SHOWING MAXIMUM POST SPACING. D. SEE SHEETS S6.x AND S7.x FOR POSTS CONNECTIONS & DETAILS. 5-=OUNOATIONS A SEE SHEETS 57.1 AND 57.2 FOR COLUMN CONNECTION TO FOUNDATION. B. SEE BEAM SPAN TABLES ON SHEET SB.xx.x FOR MINIMUM FOOTING SIZE FOR PATIO COVER SUPPORTED ON CONCRETE FOOTING, BASED ON BEAM SPAN SELECTED. C. SEE 57.1 FOR ALTERNATE FOOTING SIZES. TABLE 1 MINIMUM NUMBER OF POSTS REQUIRING ATTACHMENT PER 3IS6.3 WITH 2 x 6.5 x D.D32 SIDE PLATES (SIDE PLATE TYPE SP3) TRIG WIND nP FED XIND-MM-URE WIDTH 11DC 120E 12OC 1309 13DC 5 2 2 2 3 3 3 8' 2 3 3 3 3 4 7' 2 3 3 4 3 4 8' 3 3 3 4 4 5 9 3 4 4 4 4 5 ur 3 4 4 5 5 6 il 4 4 4 5 5 6 12 4 5 5 e 5 7 WITH 2 x 6.5 x 0,042 SIDE PLATES (SIDE PLATE TYPE SP4) TREB SPE WIDTH 1109 11DC 120E 120C 130E 13DC F 2 2 2 2 2 3 6' 2 2 2 3 3 3 7• 2 3 3 3 3 4 w 2 3 3 4 3 4 1? 3 3 3 4 4 5 117 3 4 4 4 4 5 11• 3 4 4 5 5 6 17 3 4 4 5 5 5 NOTES: 1. NUMBER OF POSTS SHOWN IN THIS TABLE IS A MINIMUM. ADD POSTS AS REQU IRED TO ENSURE THATTHE "MAX POST SPACING (SPAN)" SHOWN ON SHEETS SB.xx.x IS NOT EXCEEDED. 2. THIS TABLE IS TO BE USED IN CONJUNCTION WITH DETAIL 3/S6.3 3. THIS TABLE DOES NOT APPLY IF THE SIDE PLATES ARE PROVIDED FOR AESTHETICAL PURPOSES AND THE BEAM IS CONNECTED TO THE COLUMN DIRECTLY PER 2/56.3 OR WITH A BRACKET PER 1/54.5 & 1/S6.3. ( �TAIBILE MINIMUM NUMBER OF COL TOP ATTACHMENT PER 3/S6.3 SHEET INDEX - SOLID PANEL STRUCTURES: TYPE D GO.1 -TITLE SHEET, DESIGN LOADS, GENERAL NOTES GO.2-IAPMOAPPROVAL S1.4 - SOLID PANEL STRUCTURES: TYPE D S1 5 - SOLID PANEL STRUCTURES: TRIBUTARY WIDTHS TO BEAMS 52.1 - SOLID PANEL STRUCTURES: SNOW LOAD DESIGN: NEED TO CONSIDER DRIFTAND SLIDING DESIGN S2.2 - SOLID PANEL STRUCTURES: SNOW LOAD DESIGN: SPAN REDUCTION FACTORS DUE TO DRIFT AND SLIDING S3.1F-SOLID PANEL STRUCTURES: FREESTANDING COVERS MAXIMUM SPANS AND MINIMUM FASTENERS 53.2 - SOLID PANEL STRUCTURES: CROSS SECTIONS S3.3 - SOLID PANEL STRUCTURES: DURAKING AND T6 PAN MAXIMUM SPANS AND MINIMUM FASTENERS 54.1 - SOLID PANEL STRUCTURES: BEAM PROFILES S4.2 - SOLID PANEL STRUCTURES: BEAM PROFILES S4.3 - SOLID PANEL STRUCTURES: COLUMN PROFILES 54.4-SOLID PANEL STRUCTURES: MEMBERS PROFILES 54.5 - SOLID PANEL STRUCTURES: CONNECTORS S4.6 - SOLID PANEL STRUCTURES: FAN BEAM DETAILS 55.1 - SOLID PANEL STRUCTURES: SPLICE DETAILS S6.1 - SOLID PANEL STRUCTURES: ATTACHMENTTO EXISTING BUILDING S6.2 - SOLID PANEL STRUCTURES: CONNECTION DETAILS 56.3 - SOLID PANEL STRUCTURES: CONNECTION DETAILS 57.1 - SOLID PANEL STRUCTURES: FOUNDATION DETAILS S7.2 - SOLID PANEL STRUCTURES: FOUNDATION DETAILS SB.xx.x- SOLID PANEL STRUCTURES: BEAM SPANS AND FOUNDATION SIZES xx PSF LLJSL, 1xO MPH G9.1 -ADDITIONAL STATE LICENSURE STAMPS SOLID PANEL STRUCTURE TYPE D: FREESTANDING MULTI -SPAN WITH OPTIONAL CANTILEVER TRI BUTARY WIDTH NP -NOT PERMITTED -SITE SPECIFIC ENGINEERING REQUIRED. ROUNDUP TRIBUTARY WIDTH AS REQUIRED TO USE DESIGN TABLES. PROJECTION O.H. CLFrAR SPAN TRIBUTARY WIOTW � s TRIBUTARY= 1/2 SPAN + O.H. NOTE: TRIBUTARY ON MULTIPLE SPANS IS EQUAL TO CENTER SPAN TO CENTER SPAN TABLE (FT) OH CLEAR SPAN (FT) (FT) 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 0 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.6 10.0 10.5 11.0 11.5 12.0 1 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 NP NP 2 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 NP NP NP NP 3 6.0 6.5 7.0 7.5 8.0 BS 9.0 9.5 10.0 10.5 11.0 11.5 12.0 NP NP NP NP NP NP 4 7.0 7.5 9,0 8.5 9.0 9.510.0 10.5 11.0 11.5 12.0 NP NP NP NP NP NP NP NP S 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 NP NP NP NP NP NP NP NP NP NP 2465 RAILROAD ST, CORONA, CA 92880 951.736.4500 �FEss 1qy44 S5$5 �9r F OF CA0F� DATE SIGNED: July B, 2019 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 SAP Mo ES TM EXPIRES ON: JUNE 30, 2020 REVISIONS MARK DATE DESCRIPTION 4STELJOB# DA02-02 DATE 07/00119 DRAWN BY RC CHECKED MDS IAPM0195 V 3.1.1 SOLID PANEL STRUCTURES: TRIBUTARY WIDTH TO BEAMS S1.5 TABLE 1A-ATTACHED COVERS MAXIMUM SPAN FOR 24" TRI-V PAN LUGSL T(IN) WIND SPEED AND EXPOSu 1108 1100 120E 1200 1308 130C 0.018 10'3" 10-3" 10'3" 10-3' 10'3' 9'-4' 10 0.024 173" f 2-3' 173" 123' 12'3' 12s3" 0,032 14'3' 14'-T 14'3° 14-3- 14'-3" 14k-r 0.018 8'-4' 8'-" 8'-4" 8'A' 8'-4" 8'-4' 20 0.024 i0'-1" 10-1" 10'-1' 10-1' IVA' 10.1" 0.032 12'-l' 1Z-1" i7•i' I 12.1' 12'-1' 12-1' 25 0.018 7-3' 73' 7-3" T3" Tk T-3' 0.024 8'-9" V-9' Ir_r 81-9" 8'•9" 81-3" 0.032 Y-W 9'3" 9- r 93" 91-8" 9'43" 30 0.018 6-7" 6'-7" 6-T' V-T' 6'-T' 6'-7" 0.024 IN 8 3" 8'-3' 8'-3" 0, r B' 3" 0.032 1 9-1" 9'-1" 9-1" T-1" TV TABLE 2 -MULTI SPAN REDUCTION FACTORS ROOF PANEL TYPE ROOF LNE / GROUND SNOW LOAD (PSP 10 F2D 25 30 40 50 24 x 2-1/2 x 0.018 0.85 0.80 0.65 0.65 - - 24 x 2-1l2 x 0.024 0.90 0.88 0.7D 0.65 - 24x2-112x0.0 2 0.9Q 0.88 OTHERS - TABLE 1 B -ATTACHED COVERS MAXIMUM SPAN FOR 6 x 2-1/2 FLAT PAN LUGSL T(IN) WIND SPEED AND EXPOSURE 110B 110C 120E 120C 130B 130C 0.020 14-7" 14-7" 14'-7' 14-7" 14'-7" 14'-7" 10 0.024 15-10' 15'-10" 15-10" 15'-1 D" 15-10" 15'-10" 0.032 16'-D" 1 s-D" 18'-0" 1 &-T 18'-0" 16-a' 0.040 19'-4" 194" 19'-4" 19-4" 19'-4" 19-4" 20 0.020 i7-1" 12-1" 12'-1" 12-1" 1Z-1" 17-1" O.D24 13'-3" 13-3" iV-a" 13-3" 13'-3" 13-3" 0,032 15 6" 15-6" 1513" 15-6" 1513" 15-6" 0.040 16'-8" IG4r 16'-B" 10-T 1V-8' 18-8" 0.020 10'-4" 117 4" 10'-4" 10-4" W-4' 104" 25 0.024 17-1" 1i'•t` 1i'-i" 11'-f" 11'-1° 17'-1" 0.032 12' 1" 12-1" 12'-1" 12-1" 17-1" 17-1" 0.040 13' 1" 13-1" 13'-1" 13-l" 13'-1' 13.-V 0.02D 9-V 9'-9" 9-9" 9'-9", 9-9" 9'-9. 30 0.024 10-4" 1 a-4r 10'4" 1 a-4" 10'-4' 1 a-4- 0.032 11-4" 1 Y-" 1 V-4" 1 T-4" 11'-4" 1 T-4" 0.040 17-3" 1Z-3" 12'3" 12-3" 12'-3" 17-3 0.020 9-0" 9'-0" 94O" 9'-0". 9-0' 9'-0" 40 0.024 3-F 943" 9-6" 9'3" 9-8" 913" 0.032 10'-4" 10-4" 1 U-0 10=4" 10'-4" 1(7.4" 0.040 11'-2" 1 T-2" 11'-2" 1 T-2" 11'-2" 1 T-2' 50 0.020 IM" 8'3" 9-3" 8-3" 9-3" 813" 0.024 9-9" 8'-9- 8'-9" 8'-9" 9-9' 8,-9" D.032 9'3" 93" 948' 94$" 9-8" 9'3" 0.040 10'-4" 1 a-4" 104" 1 a-4" 10'-4" 1 10-4" TABLE 1C -ATTACHED COVERS MAXIMUM SPAN FOR 8. x 2.112 FLAT PAN LUGSL TON) WIND SP FEEDAN EXP 5 RE 110 8 .1100 120 E B 130 B 1300 0.020 12' 6" 72' G 12'�" 13 12 6" 10 0.024 13'-7" 13' 7" 13'-7" 13-7° 13'-7" 13'-7" 0.032 15'' 15' 7 1 S 7" 15-7" 15-T 15-7" 0.040 17'-7" 1 T 7' 1 T-7" 1 T-7" 1 T 7" 1 T-7" 20 0.020 10'-2" 10' 2" 10'-2" 10.2" 10'-2' 10-2` 0.024 11-4" 11'-0" 11-41 1 T-4" 11-4" 1 T-4" 0.032 13'-0" 1 IT-O' 13'-0° 1 13-0' 13'-D° I 13'-0" 0.040 14'-6" 14'-V 14-6" 14-0" 14-6" 14-0" 0.020 9'-9" 9'-T 9-9" 9-9" 9-9" 9'-F 25 0.024 10'-0" 10'-4" 10'-4" 10.4" 10=4" 10'-4" 0.032 11'-4' 11'-0" 11'-4" 1 T-4" 11'-4" 1 T-4" 0.040 12'3" IT3" 12'-3" 17-3" 12'-3' 12-3" 0.020 9'-3" 9-3" 91-3" 9-3' 93" T3" 30 0.024 9'-9" 9-9" 9'_9" 91-9" 9.91. 91_91. 0.032 1 U-9" 10'-9" 10'-9" 10-9" 10-9" 10-9' 0.040 1 r-7" 1 l'T" 11'a" 1 r-7" 1 r-7" 1 T-T' 0.020 8'-4" 8'-4" 8'-4" 8-4" 8'-0' 8'4" 40 0.024 9'-0" 9'-0" 9'-0" 91-0" 9-0° 9'-0" 0.032 9-9" 9'-9" 94-9. 9'-9" 9-9" 9'-9" 0.040 10'--r 10-7" 10'-7" 10-7' 10'-7' 1 a-T' 0.020 T3" 7'-5" T-5" T-5" 7-5" T-5" 0..024 8'3" 8-3" 8-3" 6'-3" 8'-3"50 0.032 9'-1" 9'-1" 9-1• 9,-1' 9.1" 9_i° 0.040 9'-9" 9-V 9,_y" 9, 9" g_9" 92" (1) #10-16 TEKS OR SMS AT EA (4) 0.40" ALUM. ALLOY 3004-H36 ALUM. ALLOY 3004-H36 TOP FLUTE ATTACHMENTS TO BEAM B1 (1) 110-16 TEKS OR SMS AT EA. (2) OR TO WALL HANGER. SEE NOTE 2. 0.35" 0.40" 0 25" TOP FLUTE ATTACHMENTS TO B1 OR 0.67"(2) #10-16 TEKS OR SMS OAT TO WALL HANGERS. SEE NOTE 2. 0.40" o @ EA. (3) BOTTOM FLUTES 0.88" M 0-N (1) 110-16 TEKS OR SMS 0.35" o TO EA. (3) BOTTOM FLUTES h 0.69' ri OAT T �i r`ni o o N O (V 0.35' 6j 0.375" EQ. EQ. EQ. 0.375" 3.00" 4.50" 4.50' 4.50" 4.50" 3.00" o 0.75' 0.75" 24.000" 6.00" OR 6.OT 3 24' x 2-1/2' TRI-V PAN 2 6' OR 8' x_2-1/2' FLAT PAN 1 NET USED 3°_1'-0" NTS TABLE 1 A -FREESTANDING COVERS MAXIMUM SPAN FOR 24" TRkV PAN LUGSL T(IN) WIND SPEED AND EXPOSURE 110B 1100 1208 1 120C 130B 130C 10 0.018 V-a' a-6' 8'-7' i 8'-1" 6-2' T-V 0,024 10`-4•' 9-9' 9-9' 9-2" 9-3" 87' 0.032 12--8" 12-1" 12-1" 11'-2" 1 T-3' 19-8" 20 0.01$ T-9" T-5 7-5" T-2 7-2" 6-1D" 0,024 8'-B" W-4" 6-5' 6-1" 6-1" T-9' 0.032 19-9" 10'3" 1a-4" 9-8" S-9" 9'-9' 0.018. 7-8" T-4' 7-4" T-1" T-1" 6'-1a' 25 0.024 8'$" 8'-4' 8'-S" 8'-1" 8'-l" 7-9" 0.032 10'-6" 10'-2" 10'-2' 9-T' 9-8" 9-7 30 0.018 T3" T-a' T-0" V-9" 6-10' S-T' 0.024 8'3" 8'-a' 9-0" T-9" 7-9' T-5" 0.032 9-10" 9'-T 9-6" 9-1" 9-7 8'-10" TABLE 2 -MULTI SPAN REDUCTION FACTORS ROOF PANEL TYPE ROOF LIVE / GROUND SNOW LOAD (pst 10 20 25 30 40 50 24x2-l12xO.O18 0.85 0.80 0.65 0.65 - - 24 x 2-112 x 0.02 0.90 0.88 0.70 0.65 - 24 x -112 x 0.03 0.90 0.88 - - OTHERS - - - - - El TABLE 1 B - FREESTANDING COVERS MAXIMUM SPAN FOR x2-1/2 FLAT PAN LLIGSL T(IN) WIND SPEED AND EXPOSURE 1109 110C 120E 120C 130E 130C 0.020 12.8" 12'-0" 12'-0" 11'-4" 11'-6" 10'-9' 0.024 15'-10" 14-2' 13'-4" 13'-4" 12.8" 17-1" 10 0.032 116 2' 16-8" 16-9" 16-a' 16-1" 14-Y 0.040 1T-0" 115-10" 1T-0" 194' 16' .' 15-0" 20 0.020 1a-10" low 1a3." 9-9." 9-10" 9-5" 0.024 12-2' 11'$" 11'$" 11'-2' 11'-3" 10'-T' 0.032 14'-2' 13-9' 13-7" 1V-O' 13'-1" 12-8" 0.040 16S' 15 2" 15'-2" 14-10" 14-10" W-3" 25 0.020 1V-V 1a-1" ia3" 9 8' 9-9' 9-4" 0.024 12-0" 11'F" 11'-7' 10-10" 11'-0" 10'-6" 0.032 14-1" 13-7' 13'$" 13'-1" 13'-2" 12'4" 0.040 15'-4" 16-1" 15'-1- 14'-8" 14-9" W-1" 0.020 9=11" 9-7" 9-T' 9-2' 94" 6-11" 0.024 1T-4" 19-0" 1l-T 10' 4" 1O'-6" 9-11" 30 0.032 13'-2' 123" 13-0" 12-6" 12-T' 11'-10" 0.040 14-9' 14-T 14T' 14'-1" W-1" 13'-7" 40 0.020 9-1" 8'-10" 8'-10" 6-T' 8'-6" 8-1" 0.024 1V-2' 9-10" 9-10" 9-7' 9.8" 9'-3" 0.032 10'3" 10'-1" 1174" 9-10" 9-10" 9.8" 0.040 13'S" 13'4' 133" 1S-0' IVA" 12-T' SO 0.020 T$" T-T' T-8" 7-6, T--G' T-2' 0.024 8-9" 8'•T' 8'-T' 6-5" 8'-' 8'-1" 0.032 10'4' 10'3" 1 a3" 10'-1" 1 V-1" V--9' 0.040 11'-10" 11'-T' 1 11' 9" LI1-6' I 11'-6" 11'-2" NOTES FOR DECK ATTACHMENT TO SUPPORTING BEAMS AND WALL i•{AINGERS: 1- MINIMUM ATTACHMENT OF PANS TO BEAMS (EXCEPT BEAM PROFILE B1) SHALL BE MADE WITH (1) OR (2) #10 SMS OR TEK SCREW AT EACH BOTTOM FLUTE, AS SHOWN IN DECK PROFILE ABOVE 2- MINIMUM ATTACHMENT OF PANS TO BEAM PROFILE 61 SHALL BE MADE WITH (1) OR (2) #10 SMS OR TEK SCREW AT EACH BOTTOM FLUTE, AND (1) #10 SMS OR TEK SCREW AT EACH TOP FLUTE, AS SHOWN IN DECK PROFILE ABOVE. 4 - MINIMUM ATTACHMENT REQUIREMENTS ABOVE DO NOT APPLY TO GUTTERS OR CSHAPED DECK CLOSURE PLATES THATARE NOT USED AS BEAMS (NON-STRUCTURAL MEMBERS NOT CONNECTED TO COLUMNS AND INSTALLED AT THE END OF AN OVERHANG OR PARALLEL TO THE DIRECTION OF THE DECK) 5- WHEN ATTACHING TO BEAMS 89, B10. B15, 816 OR B19 (DOUBLE MEMBERSI ATTACHMENT CAN BE MADE TO EITHER MEMBER OF THE BEAM, BUT SHALL BE EVENLY SPLTi BETWEEN THE 2 MEMBERS. TABLE 1C - FREESTANDING COVERS MAXIMUM SPAN FOR 8 x 2-1/2 FLAT PAN LLIGSL T (IN) WIND SPEED AND EXPOSURE 110E 110C 120E 120C 130B 130C IV-10" 10'-1" W-5r, 91-F 9-7" 91-0" 0.024 12=1" 11'4" ll-6' 10'•8' 10'-10" 1a-1" 10 0.032 14'-1" 13'-1" lV4' 12'�" 12-S' 12-0' P0.020 0.040 15'-7" 14'-10' 14-10" JN' 1" 14-2" 134L 20 0.020 9-1" 8'-9" 6-9" 8'-4" 8'-6" T-11" 0.024 10'-1" 9-61 9-9' 9-3" 9.5" 8-11" 0.032 11'-10" 11'-4" 11'-0" 11'"0" 11'-0" 1a-6" 0.040 13'F" 12'-10' 13'-0" 12-4" 12'-6" 11'-10" 0.020 8'-11" V-8" 6-8" 8' -3" 8-3" 7-1a' 0.024 9'-11" Sr-7 9-79-2" 9-3" 8-10" 25 0.032 11-10" 11'4' 113" 10'-9' 10'-10" 117 4" 0.040 IV-3" 12-0" 12.9' 12'-3' 12-4° 11'-9" 0.020 8'-5" 8'-1" 6-1" T-9' 7-10" 7 -W 0.024 9-6" 9-1" U-2' 8'-10' 6-11" 814, 30 0.032 11'-1" 1a3" 10'-9' 101-4" 10=4" 19-0" 0,040 1 12'-T' 1T-2" 1T-2' l l'-8' 11'_9" 11'-3" 40 0.020 T-8" T-6" 7-6" 7-3" T-2" 6-11" 0.024 8'-8" 8'-3" 6-3" 8-0" 8'-1" T-10" 0.032 10'-2' 9-10" 9-1a' I 9-7" 9'-T' 9-T 0.040 11'-6" 11'-2" 11'-2' 10'-8' 10'-10" 19-6" 50 0.020 6-T S-S' 6-5" 6-3" 6-3" 6'-l" 0.024 7-4" 73"' 7-3" T 1" T-O" 6-11" 0.032 6-9' 8'-T' 6-6" 8'-6' 8-4" 8'3" 0.040 9-10' 9-9" 9-9" 9-5" 9'-T' Y-2" 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 6~SS r S585 � OF CAL�F� DATE SIGNED: July 8, 2019 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949,305.1420 �Ap MO ES TM EXPIRES ON: JUNE 30, 2020 REVISIONS MARK DATE DESCRIPTION 4 STEL JOB # DA02-02 DATE 07/08119 DRAWN BY RC CHECKED MDS IAPM0195 V 3.1.1 SOLID PANEL STRUCTURES: FREESTANDING COVERS MAXIMUM SPANS AND MINIMUM FASTENERS S3.1 F TABLE 1 -SOLID PANEL STRUCTURES FASTENER SPACING SCHEDULE SEE NOTES 1 AND 2 IRP ROOF PANEL WIND SPEED AND EXPOSURE 110 (ram) B. C 120 (MPH) B C 130 (Mpm B C 3"- 0.024" A A A A A A 4.25" - D.024° A A A A A A A- A A A A B 4,29 - 0.030" A B B B B B EI.D0--omwl B B B B B B ROLL FORMED OR (E) BLDG. WHERE OCCURS INSULATED ROOF PANEL INTERLOCKING SEAMS, TYP. • � f I I f l i ! .! I f � I r l •+ � I i i I€ I t I � I I I ! I I I ! I } ! L I @IRP I C I 1 I I i I 2B 1) 2) A: 6" D.C. TOP CONNECTION TO BEAMS 12" O.C. T&B CONNECTION IR HANGER B: 4" D.C. TOP CONNECTION TO BEAMS 8" O.C. T&B CONNECTION IR HANGER FASTENER SPACING SCHEDULE N.T.S. 1 @IRP B @RFP A PLAN VIE1M11 N.T.S. I ' 1 COLUMN SEE SHEET S4.3 BEAM, SEE SHEETS 54.1 & S4.2 @RFP ' OPTIONAL DECORATIVE FASCIA (WOOD, ALUM. OR HARDBOARD) #10 S.M.S. TOP & BOTTOM, IR HANGER PER SPACING PER 3/S3.2 1/4" TEKS W/ SPACING EXTRUDED EXTRUDED 9/54.4 SLO� PE PER 3/53.2 "IR3" GUTTER DRIP EDGE SEE NOTE 2 14 SMS @ 32" D.C. #8 xYt" TOP & BOTTOM TO BUILDING WHERE OCCURS " ! ' f My'I� �! 4 MIN. PER EACH JOINT @ 12" O.C. // %� ll" PER 4/56.2 / f f ' /f 3" OR 4Y4NON-STRUCTURAL DURAPANEL, SEE NOTE 1 #8 x N' @ 12° O.C. g TOP &BOTTOM OPTIONAL FASCA �: '• f BEAM PER S4.1 & S4.2 OPTIONAL : f (3 x 8 BEAM SHOWN) RAIN GUTTER ALUMINUM SKINS IRP MAX SPAN PER APPROVAL MAX OVERWG PER N07E TOP & BOTTOM 0.024" REPORT - SEE NOTE 1 10 ON S1.x BX£ OF Ifi? ROOF NOTES: (SEE 3/53.2 FOR 1. THE IRP ROOF PANELS USED WITH THE PATIO COVER STRUCTURES RECOGNIZED IN THIS EVALUATION REPORT MUST BE A DURALUM PRODUCT PER IAPMO-ER-505, GCfHVION TO EU D10 CALIFORNIA FBH CA-LRP-2410 OR CA-LRP-3220. 2. THE SLOPE OF THE IRP ROOF PANELS SHALL BE PER THE IAPMO OR FBH REPORTS LISTED ABOVE. RECOMMENDED MINIMUM SLOPE IS ° PER FOOT AT COVERS DESIGNED FOR LIVE LOADS, AND V PER FOOT AT COVERS DESIGNED FOR SNOW LOADS, INSULATED ROOF PANEL (IRP) INSULATED ROOF PANEL [IRP] INTERLOCKING JOINT N.T.S. N.T.S. #14 SMS @ 2° FROM EA. END #8 x Y" ROOF HANGER FASTENER MAX OVERHANG PER NOTE 10 ON S1.X MAX, AND @ 32" D.C. MAX @ 12° O.C. PER 12/S4.4 SEE TABLE 3 ON S3.1A OR S3.1F 3/e° PER FT FASTENER 10d x7T @ EACH (4 MIN. PER PANEL INTERLOCK) MIN SLOPE I SEE TABLE 3 ON PANEL INTERLOCK S3.1A OR S3.1F �--- - -- - -- - - r - - ---- ATTACHMENT TO BUILDING WHERE OCCURS -L PER 4/S6.2 I GUTTER PER S4.1 OR S4.4 ROLL FORMED PANEL PER SHEET S3.1A` S3.1 F, OR BEAM PER 54.1 & 54.2 10 x 7T @ EACH ROLL FORMED PANEL S3.3 (3 x 8 BEAM SHOWN) VALLEY PER SHEET S3.11A, S3,1F, AND S3.3 ROLL FORMED PANEL (RF) ROLL FORMED PANEL (RF) TO `� INTERLOCKING JOINT 3' = 1'-0" 1B HEADER BEAM CONNECTION N.T.S. TABLE 2 -ATTACHED AND FREESTANDING COVERS MAXIMUM SPAN FOR DURAKING PANEL LUGSL T(IN)WIND SPEED AND F)POSURE 110B I 110C 120B 120C 130E 1 130C 0,020 15.10- 14'-9' 14-10" 13'-T' 13'-1D" 12-0" 0.024 17-11"" 16'--7' 16-9- 15'-5" 15'-B" 143" 10 0.032 2Z-0" 20'4 20'-7' 18'3" 18'-11" 1T-2' 0.040 26-10" 23'-11" 24'-2' 21'-11' 22'-3" 20-2' 0.020 13-11' 13'-0' 13'-7' 12.1" 1Z-5" 10'-10' 0,024 15'-9" 15'-3' 15'4' 14'-5" 14' 7" 13 7" 20 0.032 19'--2' 18'-9 19=10" 1T-8" i7-11" 15-9' 0.040 20-7" 2D'-7' 20'-7' 20' 7' 20' 7" 19 7" 0.020 13-11" 13'-T 13'-7' 12'-i" 12-5" 1 10'-10' 0.D24 16-9" 15'-3' 15'-4' 14'S" 14'7" 137" 25 0.032 19-2' 18'-9 16'-17 1TZ IT-11"M97'-4" 0.040 20'-T' 20'-7' 20' 7' M-7" 20' T 0.020 13-3" 1Z-7' 12'-7' 11'-0" 11'-11" 0,024 15'-D" 14'-8' 14'-8' 14'-1" 14'3" 30 0.032 18'-4' 18'-D' 18'-1' 17'-4" 1T T' 0.040 19-9" 19'-9' 19'-9' 19'-9" 19'-9" 0.020 1M' 10'-3 iV-7 9'-10' $=11" 0.024 13'-2" 13'-2' 1T-2' 12'•11" 13'-0" 12.8" 40 0.032 16'-3' 16'-3' 16'3' 15'-11" i6'-0" 15-7' 0.040 18'-D" 1"' 18'-0' 18'-0" 1 "" 1 B'-0" 0,020 8'-3" 8'_3" 8'-3' 8'3' 8'3" 8'-1" 0,024 11-9' 11'-9' 11'-9' 11'-9" 11'-9" 11'3' 50 0.032 14' T 14'-7' i4'-7' 14'-7" 14'-7" 1 14'-5' 0.040 16'-8' 16'-B' 16'3' 16'3" 16'3" 19-8" 0.020 6'-11' 6-11' 6-11' 6-11" 6-11" 6=11" 60 0.024 9'-11" 9'-11' 9'-11' 9-11" 9-11" 9'-11' 0.032 13'-4" 13'-' 13'"4' 13'-4" 13'-4" 134" 0.040 15'-8' 15'-8' 15'-8' 151$" 16-8" 18-8" 0.020 5'-10' 6-10' 6-10' 5-10' 6-10" 5'-10" 0.024 V-4" 8'4' 8-4' 8'-4' 8'-4" 8'-4" 72 0.032. 12'-3' 12'-3' 12'3' 12'3" 12'-3" 123" 0.040 14''4' 14'-4' 14'-4' 14'-4" 14W 14'-' 0.020 5-D" 5-0" 5'-0' 5'-0' 5'-0" 6'-0." 84 0.024 7'-2" 7'-2 T-2' T-2' T 2" T 2' 0.032 11'-4" 111' 11'W i V-4" 1 V-4" 1 T-4' 0.040 1 13'-3' 13'-3' 13'3' 13'-3" 13'-3" 134" TABLE 1 -ATTACHED AND FREESTANDING COVERS MAXIMUM SPAN FOR T6 PANEL LUGSL T(IN) WIND SPI:rzOAND EVOSURE 710B 110G 1 120B 120C 130E 130C 10 0.024 16-11" 16'-1' 16'-2' IV-4' 15'-6" 14'-7" 0.032 20-10" 19'-10" 19'-11" 1B'-1IT. 19'-1" 18-0' 0.040 23'-6" 22-2' ZZW 20'-11" 21-2" 19'-10" 20 0.024 14'-5" 13'-11" 13'-11" 13'-4" 13'-0' 12'-11" 0.032 IT--6' 17'-1' 1T-2' 16'-6" 15-r 16-10" 0.040 19'-6' 1 B'-9' 1 B'-9' 1 B'-9" 181-9" 18'1P' 0,024 143" 13'-8' 13'-9' 13'3" 13'-4" 12.9" 25 0.032 17-1" 16'-11' 16'-11" 16'-3" 161-Y 16f 0.D40 19'-1" 18'-5' 18'-6' 18%5' JV-Y 0.024 13'-6' 1T-0' IVA' 12'-T' 12'-B" 12-2" 30 0.032 16'-1" 16'-1' 16'-1' 15'-7" 16-8" 16-0" 0.040 18'-1' 17'-6' 17T 17'-0" 1T 1T-1" 40 0.024 12'-" 12'-0' 12'-0' 11'$" i1'_a 11'A' 0.032 14'-8" 14'-8' 14'3' 1414" 141S" 13'-11" O.D40 1V-G' 16'-1' 16'-1' 15'-9" 16'•9" 153" 50 0.024 11'-4" 10=11" 11'-0' 10'3" 10'3" 0.032 13'-B 13'-B' 13'3' 13'-4" 13'-" 13'-0" 0.040 15'-2" 14'-11" 14'-11" 14'-B" 14'3" 1 14'3" 0.024 9.6" 91-0" 916' 913'rlZ-V B'-10" 60 0.032 12=9" 12-9' 12'-9' 12'-7" 12-0" 0.040 13'-10" 13'-1O" 13.'-10" 13'-1O'" 13'-1T 0.024 9-0' 8'-0" 8-0' 8'-0'720,032 11'-9' 119' 11'-9' 11'-9" 1 T-7" 0.040 13-0" 13'-0` 13'-0' 13'-0" 13'-0" 0.024 6'-1 V 6'-11' 6-11' 6-11" 6-11" 6'-11" 84 0.032 10-11" 10'-11" 10'-1 T' 10'-11" 10'-11" 10'-11" 0,040 124" 12'-4' 12'-0' 12'4' 12' V 12-0" ALUM. ALLOY 3004-Hn IALUM. ALLOY 6063-T6 JAjum. ALLOY 60 T6 ALUM. ALLOY 3004-1136 1.625" 'po 0.620' o ly��po 1.250' -� 0.25" I o 0.81" c o CONTINUOUS I t2 c9 °C' INSERT I N 0,76' N 0,030 c I o cD 0.850" cD TYP. ui °o 9 n fo I oo m � N ---' 4.00" ?I 000 3.020' 2.000" 4.0W 2.OD0" Mo BEAM PER 86 NOTES: MAA 1.750' 1. SEE 10/S5.1 FOR SPLICE DETAIL WHERE OCCURS. NOTES: 2. THIS GUTTER IS USED WITH 6" OR 8' FLAT PANS OR 1. SEE 4/S5.1 FOR SPUCE DETAIL WHERE OCCURS. 24" TRl--V PANS. 2. THIS GUTTER IS USED WITH 6' OR 8" FLAT PANS OR 24" TRI-V PANS AND T6 PAN. B1D DBL 2 x 61/2 x OA32'-BEAM MAG GUTTER_ e. l 6.5' ROLL FORMED GUTTER FASCIA 3"=1'-0" �J W/ INSERTS 3"=V-0' ALUM. ALLOY 3004-436 ALUM. ALLOY 6063-T6; ALUM. ALLOY 3004-H36 JALUM. ALLOY 5063-TG STEEL ASTM A65.3-SS GRADE 50 G60 2.908" I I � R0.380" �• ll 14 CONTINUOUS I I o "C" INSERT 11 N w 0.042 o PER B7 I I m o 0 0.062" N coo EA. SIDE 1 1 cq cR TYP I 1 f I k } 3.000 SPLICE WWHERE OCCURS BEAM PER B6 3.000' a,, 3 x 8 x 0c142' nn P BE INSERTS nt 3' SQ. x 0.032- ALUM. BEAM W/- B2 MAG BEAM W/ [2f 'C INSERTS 12 Oa STL 'lr CHANNEL ALUM. ALLOY 3004-H36 IALUM. ALLOY 3M Mm. ALLOY JALUM. ALLOY 606:46 SPLICE r, WHERE N OCCURS d 1.500' O G 0.042' n TYP o 0 0.042' _ 0 0 0 0 0 o TYP. �i u�i 0.109" cD o 0 0.085" o cc r ,� N TYP 3.00D° 2.00D' 4.000" 2.000' 4.000" ` NO SEE 5/55.1 FOR SPLICE DETAIL WHERE OCCURS. 3.000" 4,pOp' 3.000" MAX NOTE MAX 1. SEE 6/S5.1 FOR SPUCE DETAIL WHERE OCCURS. DBL 3 x 8 x 0.042' 89 DBL 2 x 81/2 x 0.042' 66 T I -BEAM 63 a I -BEAM 61� _ 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 S 58 5 LCT 4 `e 9pE OF CAS DATE SIGNED: July 8, 2019 tPA T95L =�r����=fir£: �E; l ar_• �::.� 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 �Ap V ES TM EXPIRES ON: JUNE 30, 2020 REVISIONS MARK DATE DESCRIPTION 4 STEL JOB # DA02-02 DATE 07/08/7B DRAWN BY RC CHECKED MDS IAPM0 195 V 3.1.1 SOLID PANEL STRUCTURES: BEAM PROFILES S4.1 ALUM. ALLOY 3004-H36 STEEL ASTM A653-SS GRADE 50 G60 ALUM. ALLOY 3004-H36 STEEL ASTM A653-SS GRADE 50 G50 ALUM. ALLOY 3004-H36 STEEL ASTM A653-SS GRADE 50 G60 ALUMINUM BEAM & CONTINUOUS STEEL INSERT PER B18/S4.2 TYP. I i 3.000" ! 4.000" 3.000" MAX. B1- DBL 3 x 8 x 0.047 w/ 12 GA. STL 1? CHANNEL 3"=1'-O" 0.25" 0 0.81" N 6 0.76" g 0 0 00 0 ri $ o ,n 0 1 4.06" 1 B20 DLIRAKiNG GLITTER ALUMINUM BEAM & CONTINUOUS STEEL INSERT PER J314/S4.2 TYP. 0" 4.000, l 3 MAIL. �DBL3x8x0.042' a"' w/ 12 GA. STL INSERT 3"=r-o" B1T FAN BEAM 0.9845" ALUM. ALLOY 6063-T6 NOTE: SEE 1/54.6 FOR DETAILS AT FAN BEAM. ALL TMM. ALLOY 3004-H36 ^"EL ASA653 SS GRADE 5o G60 B18 3x8x0.447w/ 12 GA STL V CHANNEL 6"=1'-O A. 1N000S L INSERT 3x8'x0"047 w/ 14 GA. STL INSERT ALUM. ALLOY 3004-H36 1 229" STEEL ASTM A653-SS GRADE 50 G60 .a FINUOUS L INSERT 2.824" 3.000" 914 3xWx0D47 w/ 12 GA STL INSERT 3"=1'-0" ALUM. ALLOY 3004-1136 STEEL ASTM A653-SS GRADE 50 G60 ALUMINUM BEAM & CONTINUOUS STEEL INSERT PER B13/54.2 TYP. ` 3.000" 4.000' MAX. B15 DBL 3 x 8 x 1104T w/ 14 GA STL INSERT 3"=1'-0" 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 Fm! f S 58 5 E OF CA��F DATE SIGNED: July 8, 2019 ►/ I T«. 26030 ACERO, SUITE 2DO MISSION VIEJO, CA 92691 949.305.11501 FAX 949,305.1420 �Ap �o ES OTM EXPIRES ON: JUNE 30, 2020 REVISIONS MARK I DATE DESCRIPTION 4 STEL JOB # DA02-02 DATE 0710&19 DRAWN BY RC CHECKED MOB IAPM0195 V 3.1.1 SOLID PANEL STRUCTURES: BEAM PROFILES S4.2 ASTM A500 GRADE B ASTM A500 GRADE B ALUM, ALLOY 3004-H36 ALUM. ALLOY 30047 3" ALUMINUM OR STEEL POST PER PLAN N o. O 0.188" 0.032• 0.188" la 20 0 0 w ri c ri 3-ODtl' 0.042" 4.DD0• NQTF: NOTE: 2.Ooo" 3.000" 2.000" IT IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) WITH IT IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) BY T ALUMINUM BENT PLATES FOR AESTHIETICAL PURPOSES. NO FASTENERS SECTION Cl FOR AESTHETICAL PURPOSES. NO FASTENERS ARE REQUIRED. NOS ARE REQUIRED. SLEEVE SHALL EXTEND FROM THE FOUNDATION TO THE SLEEVE SHALL EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF SEE TABLE 1 ON S1.x FOR APPUCAT10N OF THIS DETAIL UNDERSIDE OF THE BEAM/COLUMN CONNECTION. THE BEAM/COLUMN CONNECTION. 0 HSS 4 x 4 x 3/16 _ r n3� [ASS 3 x 3 x 3/16 S� 04Z_SIDE PLATES � T SQ" x OD37 ALUM. POST 3"4-0" ASTM A500 GRADE B ASi1M A500 GRADE B ALUM. ALLOY 6063-T6 JALUM. ALLOY 3004-H36 0.762" TYP. 1.500" c o 0.040•M 0.250" `co ,�0 0.250" 0 0-OE2" _ N ac -TYP o n 4. 3.000" 3.OD0" 3.000" 4.00D" NOTE: NOTE. Nam: NOTE: IT IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) WITH IT IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) BY IT IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) BY IT IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) BY ALUMINUM BENT PLATES FOR AESTHETICAL PURPOSES. NO FASTENERS SECTION Cl FOR AESTHETICAL PURPOSES. NO FASTENERS ARE REQUIRED. SECTION Cl FOR AESTHETICAL PURPOSES. NO FASTENERS ARE REQUIRED. SECTION Cl FOR AESTHETICAL PURPOSES. NO FASTENERS ARE REQUIRED. ARE REQUIRED. SLEEVE SHALL EXTEND FROM THE FOUNDATION TO THE SLEEVE SHALL EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF SLEEVE SHALL EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF SLEEVE SHALL EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF UNDERSIDE OF THE BEAM/COLUMN CONNECTION. THE BEAM/COLUMN CONNECTION. THE BEAM/COLUMN CONNECTION. THE BEAM/COLUMN CONNECTION. C11 HSS 4 x 4 x 1/4 HSS 3 x 3 x 114 �_� 3' MAG POST 3' SQ. ALUM. POST s ASTM A500 GRADEBJ ISTEEL A653 JALUM. ALLOY 3004-H36 3• ALUMINUM OR STEEL POST PER PLAN ^� 1.500" 6 0.048" N 0.400" 0.313" 0 0 _ $ Mom, M {RD.175 45V, TYP. ui rn 3.000" 3.ODG" c p 0.032• c NoL. 2.000" 3 OD0` 2.00e IT IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) BY hQm. SECTION Cl FOR AESTHETICAL PURPOSES. NO FASTENERS ARE REQUIRED. IT IS ACCEPTABLE TO COVER THIS COLUMN SECTION (FULL HEIGHT) BY SLEEVE SHALL EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF SECTION Cl FOR AESTHETICAL PURPOSES. NO FASTENERS ARE REQUIRED. NOTE; THE BEAM/COLUMN CONNECTION. SLEEVE SHALL EXTEND FROM THE FOUNDATION, TO THE UNDERSIDE OF SEE TABLE 1 ON St.x FOR APPLICATION OF THIS DETAIL THE BEAM/COLUMN CONNECTION. CS HSS 3 x 3 x 8/16 ,.0 1_�E�-T SP3 0.037 SIDE PLATES ALUM. ALLOY 3004-H36 'P 0.620' 0.25" 0.25'�Fa. 1.250' 0 0.81" 0 0.81" 0 0 ua :2 m n 0 0.76" ry m aH 0.850' 0 0.76"(] LO Co aD N � n $ o � � • rzp 60' cV c 4.00" ' 0.038" 0 0 NOTES: � 4.06' 1. SEE 10/S5.1 FOR SPLICE DETAIL WHERE OCCURS. 3.020" 2. THIS GUTTER IS USED WITH 6" OR 8" FLAT PANS OR 24" TRI-V PANS. NOTES: 1. SEE 4/S5.1 FOR SPLICE DETAIL WHERE OCCURS. 2. THIS GUTTER IS USED WITH 6" OR 8" FLAT PANS OR 24" TRI-V PANS AND T6 PAN. �� NOT _USED _ _ �_DURAI[IN� GEITTER n MAG GUTTER 60 ROLL FORMED GUTTER (TRI-V �� x=1'-o" 3"=r-0• 3"=1'-0° PAN, FLAT PAN, T6 PAN) 3"=1'-0" ALUM. ALLOY 6063-T6 2.125" 3RD SCREW WHERE OCCURS 1.500" 2.000" 4.125" 4.000" 4.860" .300" 95f2' .015' x 90' �. V-GROOYE 2 625" ATTACH EXTRUDED HANGER TO EXISTING BUILDING PER 1.375" 075' TABLES ON S6.1 TYP 2.125" t.034 EXTRUDED HANGER CONNECTION NOT USED MAXIMUM PROJECTION WHEN USING EXTRUDED SWIVEL HANGER LL/GSL (PSF) Lag Screw Diameter Wind Speed and Exposure 110B 110C 120E 120C 130B 130C 1/4" 0 13' • 6" 12' - 6" 12' - 6" 11' - 0" IT - 6' 10' - U. 10 5/16" 0 17. 0" 15- 6" 14' - 0" 14' - 0" 14' - 6" 12' - 6" 3/8" 0 18' - T 16' - 6" 16 • 6" 15 - 0" 15' - 0" 13' - 6" 1/4" 0 10' - 0" 9' - 0" Y - 6" 9-6. 8' - 6" 8' • 0" 20 5/16" 0 12' - 6" 11' - 6" 10' - 6" 10' - 6" Ill_ 0" 10' - 0' 3/8" 0 13' • 0" 12' • 0" 12' - 6' 11' - 6" 11' - 6' 10' - 6' 1 /4" 0 Y - 6' 9' _ U" 9' _ T 8' _ 6� � 8' _ 6" 8'- 0" 25 5/16"0 12'-0" 11'-6" 10'-6" 10'-6" 10'-6" 1 10'-0" 3/8"o 12'-6' 12'•0" 12'•0" 11'-0' 11'-0" 10-6" NOTES: 1-WHEN CONNECTINGSWIVELHANGERTO WALLSTUDSATI6"OC MAX, FASTENERS SHALLHAVE MIN 3" PENETRATION INTO WALLSTUDS, 2- WHEN CONNECTING SWIVEL14ANGERTO MIN 2x WOOD FASCIA @ 8" OC, FASTENERS SHALL HAVE MIN lh" PENETRATION INTO WOOD FASCIA. ATTACH SWIVEL HANGER TO (E) BUILDING PER ADJACENT TABLE (2) #8 @ 16" O.C. TO MATCH LOC. OF LAG SCREW J HANGER PER 6A/ ! A OR 6B/- - m a c�3 ca " �'X W ca w ti �V J NOTES: 1. USE OF THIS DETAIL IS LIMITED TO PROJECTION LENGTHS SHOWN IN ADJACENT TABLE 2. USE OF THIS DETAIL IS NOT ALLOWED WHEN GROUND SNOW LOAD > 25 PSF OR ROOF SNOW LOAD > 21 PSF (DURAKING PAN) 3"=1'-0" 8 x=1'-0" ALUM. ALLOY 3004-H36 ALUM. ALLOY 6063 T6 2.707" 0 2.495" 41 1.332" 1.937" .176' 015' x BIT 092' 0.202" j.' 1.500° .250" 0.35 u •5� Y' P V L Z FASTENERS PER 3/S3.2 0.145" 0.376" 0it 0.080, ATTACH ROLLED FORMED � cai =� .075' HANGER TO EXISTING z m 0.055" - APPROVED 6" INSUL � BUILDING PER TABLES 1.490' M 2.336' ROOF PANELS PER 0.3120 c c ON 56.1 ^ o ATTACH IR HANGER 2/G3.2 0 4.065" 4.861" 1 TO EXISTING BUILDING " 0.281" 8.25 PER TABLES S6.1 t�p64 .300" 0.450" 9Uf 2 0 0,040' 2.740" co TYR N 11.57 N S 625' 500" 0.56, 625" 1.550" R.08" ', <.;; _''' 1.375" FASTENERS PER 3/S3.2 O APPROVED 3" OR -k.034 1.880" 4Y4" INSUL ROOF 6B c PANELS PER 2/G3.2 a� 7 ROLL FORMED HANGER (TRI-V S IR HANGER S EXTRUDED SWIVEL HANGER CONNECTION PAN, FLAT PAN, TO PAN) 3"=1'-0" IR PANELS PER 1APM0 0505 N.T.S. (TRW PAN, FLAT PAN, T6 PAN) 3"=1--0' � � a 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 S 58 5 rq 1 rF OF Ca o DATE SIGNED: July 8, 2019 /J I T1'L_ 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 SAP MO ES OTM EXPIRES ON: JUNE 30, 2020 REVISIONS MARK DATE DESCRIPTION 4 STEL JOB # DA02-02 DATE OTIOBI19 DRAWN BY RC CHECKED MDS IAPM0195 V 3.1.1 SOLID PANEL STRUCTURES: MEMBER PROFILES S4.4 ALUM. ALLOY 6063-T6 ALUM. ALLOY 606576 1875' O.DBp' 0 • o 0 ri o 0 co O.U60� rJ NOTE: BRACKET IS ?3+' LONG V BRACKET AT COLUMN T 6"=1'-0" N.T.S. 0 2�;O- STEEL ASTM A36 0 0 CV 0 O O CR O O 0 C6 o 0 N O 0 a $pp0. • ROOF BRACKET 2- ci)�� LB x S x 1/4 x 2' Y=1'-o" p 5 �` STEEL ASTM A36 0 jl: ri 0 O N 0 O CV 0 O O N O a dM, n '��VV 20 _SNOW BRACKET_ _ 3 NOT USED L12 x S x V2 xx x x 2�2°=I'-o°=t'-o° x'=i'-o° ��=�� p�:c<_c ��' I C; I 3' 1' 1' 3" 110 SMS • MAX (8 TOTAL) It + t +1 ALUM. ALLOY 300"M JALUM. ALLOY 300"36 L��-Em -1 1 + + +I #10 SMS (8 TOTAL) II t+-- I+ t+1 _.I _-- SPLICE J -- .-- _ POST -CENTERED- LSPLICE J. -- - 112 SMS - -- — - 5PLICE_J-- - — _ _ ppsT_Cf FJiF� -..•SPLICE J 1-- #12 SMS -- BEAM B4 ON SPLICE �� 84 (24 TOTAL) BEAM 81�� ON SPLICE BEAM 87� -- (24 TOTAL} - - - SIMPLE SPLICE MOMENT SPLICE SIMPLE SPLICE MOMENT SPLICE NOTES: NOTES: 1. WHEN BEAM B4 IS USED AS AN ARCHITECTURAL GUTTER, A SIMPLE SPLICE CAN BE USED ANYWHERE. 1. WHEN BEAM B1 IS USED AS AN ARCHITECTURAL GUTTER, A SIMPLE SPLICE CAN BE USED ANYWHERE. 2. WHEN BEAM B4 IS USED AS A BEAM, LOCATED DIRECTLY ON TOP OF COLUMNS, A SIMPLE SPLICE, CENTERED ON THE COLUMN 2. WHEN BEAM B1 IS USED AS A BEAM, LOCATED DIRECTLY ON TOP OF COLUMNS, A SIMPLE SPLICE, CENTERED ON THE COLUMN BELOW, CAN BE USED AT INTERIOR COLUMNS ONLY. IT CAN NOT BE USED AT EDGE OR EXTERIOR COLUMNS. BELOW, CAN BE USED AT INTERIOR COLUMNS ONLY. IT CAN NOT BE USED AT EDGE OR EXTERIOR COLUMNS. 3. WHEN BEAM B4 IS USED AS A BEAM, LOCATED DIRECTLY ON TOP OF COLUMNS, A MOMENT SPLICE CAN BE USED AT 1/3 OF 3. WHEN BEAM 81 IS USED AS A BEAM, LOCATED DIRECTLY ON TOP OF COLUMNS, A MOMENT SPLICE CAN BE USED AT 1/3 OF THE SPAN OF ANY BEAM, EXCEPT AT END BAYS AND OVERHANGS. THE SPAN OF ANY BEAM, EXCEPT AT END BAYS AND OVERHANGS. �n l SPLICE DETAIL FOR MAG LLICE DETAIL FAR ROLL _ GUTTER (BEAM B''4) 1-1/2"=1'-0" FORMED GUTTER (BEAM ALUM. ALLOY 3004-H36 3'-0" 12' 1• 4' 1" 1" 4 1" I' 16" f" 1" 16" 1" II IY2" MAX I I Y4" SPLICE I I (8) #10 SMS SPLICE (8) Yz" BOLTS BEAM 83 I I POST CENTERED BEAM 83 MOMENT SPLICE ON SPLICE SIMPLE NOTES: 1. A SIMPLE SPUCE, CENTERED ON THE COLUMN BELOW, CAN BE USED AT INTERIOR COLUMNS ONLY. IT CAN NOT BE USED AT EDGE OR EXTERIOR COLUMNS. 2. A MOMENT SPLICE CAN BE USED AT 1/3 OF THE SPAN OF ANY BEAM, EXCEPT AT END BAYS AND OVERHANGS. r l SPLICE_ DETAIL FOR 4' I BEAM (BEAM B3) ALUM. ALLOY 3004-1-136 12" 1" 4' 1" 1" 4" 1" 1' 16' 1' 1' 16` 1" + +II++ 0110 0 I I II I I MAX II ' + +II + o 0 0 0 SPLICE I 1 (8) #10 SMS SPLICE (a) Yz" BOLTS BEAM B6 I POST CENTERED BEAM 86 ON SPLICE SIMPLE SPLICE MOMENT SPLICE NOTES 1. A SIMPLE SPLICE, CENTERED ON THE COLUMN BELOW, CAN BE USED AT INTERIOR COLUMNS ONLY. IT CAN NOT BE USED AT EDGE OR EXTERIOR COLUMNS. 2. A MOMENT SPLICE CAN BE USED AT 1/3 OF THE SPAN OF ANY BEAM, EXCEPT AT END BAYS AND OVERHANGS. ( '� �Allspm- E DETAIL FOR T 1 BEAM BIB) 2"=1'-O" TABLE 1 - MAXIMUM CLR SPAN TO ADJACENT BEAM VVHEN USING DETAIL 4/S6.2 LL/GSL (PSF) EXISTING FRAMING MEMBER AT ROOF OVERHANG BRACKETOFFSET"D" 24" 18" 12" 6" 2x4 FULL 12' 10" 19' 11" 28' 0" 28' 0" 2x6 NOTCHED 20' 6" 28' 0" 28' 0" 28' 0" 10 2x6 FULL OR 2x6 NOTCHED 28' 0" 28' 0" 28' 0" 28' 0" 2x8 FULL OR 240 NOTCHED 28' 0" 28' 0" 28' 0" 28' 0" 2x4 FULL Tv. 11' 10" 19' S" 28' 0" 20 2x6 NOTCHED ITT' 17' 10" 28' 0" 28' 0" 2x6 FULL OR 2x8 NOTCHED 19' 7" 277" 28' 0" 28' 0" 2x8 FULL OR 2x10 NOTCHED 28' 0" 28' 0" 28' 0" 28' 0" 2x4 FULL 7 4" 11' 3" 18' 7" 28' 0" 25 2x6 NOTCHED 11' 8" 170" 27' 1" 28' 0" 2x6 FULL OR 2x8 NOTCHED 18' 8" 1 264" 28' 0" 28' 0" 2x8 FULL OR 2x10 NOTCHED 28' 0" 28' 0" 28' 0" 28' 0" 2x4 FULL T 11" 9' 4" 15' 8" 28' 0" 30 2x6 NOTCHED 9' 6" 14' 2" 22' 11" 28' 0" 2x6 FULL OR 2x6 NOTCHED ITS" 22' 0" 28' 0" 28' 0" 2x8 FULL OR 2x10 NOTCHED 263" 28' 0" 28' 0" 28' 0" 2x4 FULL 4' 9' 77" 12' 11" 27' 8" 2x6 NOTCHED 7' 9" 11' 8" 19' 0" 28' 0" 36 2x6 FULL OR 2x8 NOTCHED 12' 9" IT 4" 28' 0" 28' 0" 2x8 FULL OR 2x10 NOTCHED 21' 10" 18' 6" 28' 0" 28' 0" 2x4 FULL 4 0" 6' 9" IT O" 25' 2" 40 2x6 NOTCHED 6 9" 10' 5" 17' 6" 28' 0" 2x6 FULL OR 2x8 NOTCHED 11' 4" 166" 26' 7" 28-0" 2x8 FULL OR 2x10 NOTCHED 19' 7" 276" 128' 0" 28-0" 2x4 FULL 3' 9" G 4" 11' 0" 23' 10" 2x6 NOTCHED G S' T 11" 16' 4" 28' 0" 42 2x6 FULL OR 2x8 NOTCHED 10' 9" 158" 24' 11" 28' 0" 2x8 FULL OR 2x10 NOTCHED 18' 7" 15' 10" 25' 2" 28' 0" 2x4 FULL 2' 10" 5' 2" 9' 8" 20' 4" 50 2x6 NOTCHED 5' 1" 8' Z' 1 14' 2" 28' 0" 2x6 FULL OR 2xB NOTCHED 9 9" IT O" 21' 6" 28' 0" 2x8 FULL OR 2x10 NOTCHED 15' 6" 21' 11" 28' 0" 28' 0" 2x4 FULL 2' 1" 4' 1" 76" 16. 10" 60 2x6 NOTCHED 3' 11" 6' 7' 11' 4" 16' 11" 2x6 FULL OR 2x8 NOTCHED 7 W 10' 8" 15' 9" 16' 11" 2x8 FULL OR 2x10 NOTCHED 12' B" 10' 10" 1 15' 9" 16' 11" 2x4 FULL V 5" 3' 2" 6 2" 76" 2x6 NOTCHED 3' 0" 5' 3" 65" 7 6" 72 2x6 FULLOR 2x8 NOTCHED 4' 3" 5' 4" 65" 7' 6" 2x8 FULL OR 2x10 NOTCHED 4' 3" 5' 4" 6' 5" 7' 6" 2x4 FULL NG NG NG 0' 9" 2x6 NOTCHED NG NG NG 0' 9" 84 2x6 FULL OR 2x8 NOTCHED NG NG NG 0191. 2x8 FULL OR 2x10 NOTCHED NG NG NG 0' 9" NOTES: 1- FOR 10 PSF LL/GSL, USE ROOF BRACK ETS/S4.5. .2- FOR LL/GSL>_20 PSF, USESNOW B RACK ET 6/S4.5. 3-ASSUMPTIONS: NOTCH CAN BE UP TO 1" IN 2x6, UP TO 1.5" IN 2x8 OR 2x10. 40FT MAX (E) ROOF RAFTER/JOIST/TRUSS BACKS PAN. MAX (E) ROOF RAFTER / JOIST/ TRUSS SPACI NG TO BE 2411OC. TABLE 1A -MAXIMUM CLR SPAN TABLE 1 B -MAXIMUM CLR SPAN TO ADJACENT BEAM TO ADJACENT BEAM WHEN USING ROOF BRACKET WHEN USING SNOW BRACKET PER 5/S4.5 AND 4C/S6.2 PER 6/S4.5 AND 4D/S6.2 (PSF) WIND SPEED & EXPOSURE (PSF)L WIND SPEED & EXPOSURE 11013 120B 110C 130' 120C 130C 110B, 110C 120B, 130B 120C 130C 10 17-0 15'-0" 14`-0" 1Y-0" 10 24'4' 24'-O" 21'-0" 20 20'-0" 1T-9" 18'-3" NOTES: 25 19'-3" 19'-3" 17'-9" 1- WHEN USING ROOF BRACKET PER 30 16'-3" 19-3" 16'-3" 4C/S6.2, THE MAXIMUM PROJECTION 36 13'-9" 13'-9" 13'-9" SHALL BE THE SMALLEST PROJECTION FROM TABLE I AND TABLE IA. 12'-3 12'-3" 12'-3" 42 11'-9" if-9" 11'-9" 2- WHEN USING SNOW BRACKET PER 50 10'-0" 10'-0" 10'-If, 4D/56.2, TH E MAXI MU M P ROJ ECTI ON 60 8'-3" 8!. 3' 8'-3" 5 HALL B E TH E S MALLEST P ROJ ECTI 0 N 72 7-0" 7'-0" 7'-O" FROM TABLE 1ANDTABLE IB. 84 G- 0" 6' - 0" 6'- 0" TABLE 2 - NUMBER OF SIMPSON A34s AND A35s REQUIRED BETWEEN FASCIA AND ROOF SHEATHING PER 4A/S6.2 WHEN CONNECTING PATIO COVER TO EXISTING ROOF OVERHANG TRIB 10 PSF 20 PSF 25 PSF 30 PSF 36 PSF 40 PSF 42 PSF 50 PSF 60 PSF 72 PSF 84 PSF WIDTH LL/GSL LL/GSL GSL GSL GSL GSL GSL GSL GSL GSL GSL 5 1 1 1 1 1 1 1 1 2 2 2 5 1 1 1 1 1 1 1 2 2 2 2 7' 1 1 1 1 1 1 2 2 2 2 2 1 1 2 2 2 2 2 2 1 2 2 2 2 2 2 2 10' 1 1 1 2 2 2 2 2 2 2 2 11' 1 1 2 2 2 2 2 2 2 2 NG 12' 1 1 2 2 2 2 2 2 2 NG NG A NUMBER 1 IN THIS TABLE MEANS THAT (1)A34+ (1)A35 ARE REQ'D. A NUMBER 2 IN THIS TABLE MEANS THAT (2)A34s +(2)A35s ARE REQ'D. (STAGGER CONNECTORS WHEN USING (2) IN SAME WOOD MEMBER) A34s: USE (8) SI MPSON SD9112 SCREWS TO CON NECT A345 TO (E) FASCIA AND ROOF FRAMING A35s: USE (6) SPAX # 6 x 1/2" SCREWS TO CO N N ECT A35S TO (E) ROOF SHEATHING USE (6) SPAX # 6 x 1/2" OR SI MPSON SD9112 SCREWS TO CON N ECTA35S TO (E) ROOF FRAMING TABLE 3A - FASTENERS REQUIRED AT CONNECTION OF HANGERS PER DETAILS 9, 11, AND 12/S4.4 TO EXISTING WOOD STUD WALL FRAMING TRIB WIDTH 10 PSF LL/GSL 20 PSF LL/GSL 25 PSF GSL 30 PSF GSL 3615 GSL 40 PSF GSL 42 PSF GSL 50 PSF GSL 60 PSF GSL 72 PSF GSL 64 PSF GSL 5' (2) A (2) A (2) A (2) A (2) A (2) A (2) A (2) A (3) A (3) A (3) A 6' (2) A (2) A (2) A (2) A (2) A (2) A (2) A (2) B (3) A (3) B (3) B 7' (2) A (2) A (2) A (2) A (2) A (2) B (2) B (2) B (3) A (3) B (3) C 8' (2) A (2) A (2) A (2) A (2) B (2) B (2) B (2) C 1 (3) B (3) C (3) C 9' (2) A (2) A (2) A (2) A (2) B (2) C 1 (2) C (2) C (3) C (3) C (3) C 10, (2) A (2) A (2) A (2) B (2) C (2) C (2) C (2) C (3) C (3) C (3) C ill (2) A (2) A (2) B (2) B (2) C (2) C (2) C (2) C (3) C (3) C (3) D 12' (2 A (2) B (2) B (2) C (2) C (2) C (2) C (2) D (3) C (3) C (3) D A - 1/4" LAG SCREWS W/ 21/2" PENETRATION IN MIN 2x WALLSTUDS @ 16"OC MAX B-5/16" LAG SCREWS W/2%:" PENETRATION IN MIN 2x WALLSTUDS @ 16"OCMAX C- 7/16" LAG SCREWS W/ 3'/:" PENETRATION IN MIN 2x WALLSTUDS @ 16"OC MAX D- 1/2" LAG SCREWS W/ 4" PENETRATION IN MIN 2x WALLSTUDS @ 16"OC MAX TABLE 3B - FASTENERS REQUIRED AT CONNECTION OF HANGERS PER DETAILS 9, 11, AND 12/S4.4 TO EXISTING MIN 2x LEDGER OR FASCIA TRIB WIDTH 10 PSF LL/GSL 20 PSF LL/GSL 25 P5F GSL 30 PSF GSL 36 PSF GSL 40 PSF GSL 42 PSF GSL 50 PSF GSL 60 PSF GSL 72 PSF GSL 84 PSF GSL 5' (2)@16"oc (2)@16"oc (2)@16"Dc (2)@12"oc (2)@12"0 (2)@8"oc (2)@B"oc (2)@8"oc (3)@8"oc (3)@8"oc (3)@8"oc 6' (2)@16"0 (2)@12"oc(2)@12"0 (2)@12"oc (2)@8"oc (2)@8"oc (2)@8"oc (2)@6"oc (3)@8"oc (3)@8"oc (3)@6"oc 7 (2)@16"0 (2)@12"oc(2)@12"0 (2)@8"oc (2)@8"oc (2)@8"oc (2)@6"oc (2)@6"oc (3)@8"oc (3)@6"oc (3)@6"oc 8' (2)@16"o (2)@8"oc (2)@8"oc (2)@8"oc (2)@6"oc (2)@6"oc (2)@6"oc (2)@4"oc (3)@6"oc (3)@6"oc (3)@4"oc 9' (2)@16"o (2)@8"oc (2)@8"oc (2)@8"oc (2)@6"oc (2)@6"oc (2)@6"oc (2)@4"oc (3)@6"oc (3)@4"oc (3)@4"oc 10' Q2)@16"D (2)@8"Dc (2)@8"oc (2)@6"oc (2)@6"oc (2)@4"oc (2)@4"oc (2)@4"oc (3)@4"oc (3)@4"oc (3)@4"oc 11' (2)@12"o (2)@8"oc (2)@8"oc (2)@6"Dc (2)@4"oc (2)@4"oc (2)@4"oc (2)@4"oc (3)@4"oc (3)@4"oc (3)@3"oc 12' (2)@12"D (2)@6"oc (2)@6"oc (2)@6"oc (2)@4"oc (2)@4"oc (2)0-4"oc (2)@3"oc (3)@4"oc (3)@4"oc (3)@3"oc ALL FASTENERS TO BE 1/4" LAG SCREWS W/ 1.5" PENETRATION INTO EXISTING 2x WOOD LEDGER OR FASCIA TABLE 3C - FASTENERS REQUIRED AT CONNECTION OF HANGERS PER DETAILS 9, 11, AND 12/S4.4 TO WOOD -FILLED 2xALUMINUM LEDGER TRIB WIDTH 10 PSF LL/GSL 20 PSF LL/GSL 25 PSF GSL 30 PSF GSL 36 PSF GSL 40 PSF GSL 1 42 PSF GSL 50 PSF GSL 60 PSF GSL 72 PSF GSL 84 PSF GSL 5' (2)@16"0 (2)@16"oc (2)@16"oc (2)@16"oc (2)@l6"0 (2)@12"oc (2)@12"oc (2)@12"oc (3)@12"oc (3)@12"oc (3)@8"oc 6' (2)@16"oc (2)@16"oc (2)@16"oc (2)@16"oc (2)@12"0 (2)@12"oc (2)@12"oc (2)@8"oc (3)@12"oc (3)@8"oc (3)@8"oc 7' (2)@16"oc (2)@16"oc (2)@16"oc (2)@12"oc (2)@12"oc (2)@8"oc (2)@8"oc (2)@8"oc (3)@8"oc (3)@8"oc (3)@8"oc 8' (2)@16"oc (2)@15"oc (2)@12"0 (2)@12"oc (2)@8"oc (2)@8"oc (2)@8"oc (2)@6"oc (3)@8"oc (3)@B"oc (3)@6"oc 9' (2)@16"D (2)@l2"oc (2)@12"D (2)@8"oc (2)@8"oc (2)@8"oc (2)@8"oc (2)@6"oc (3)@8"oc (3)@6"oc (3)@6"oc 10' (2)@16"0 (2)@12"oc (2)@8"oc (2)@8"oc (2)@8"oc (2)@6"oc (2)@6"oc (2)@6"oc (3)@6"oc (3)@6"0c (3)@4"oc 11' (2)@16"oc (2)@8"oc (2)@8"oc (2)@8"oc (2)@6"oc (2)@6"oc (2)@6"oc (2)@4"oc (3)@6"oc (3)@4"oc (3)@4"oc 12' (2)@16"oc (2)@8"oc (2)@8"oc (2)@8"oc (2)@6"oc (2)@6"oc (2)@6"oc (2)@4"oc (3)@6"oc (3)@4"oc (3)@4"oc ALL FASTEN ERS TO BE 1/4" LAG SCREWS W/ 2" PEN ETRATI ON I NTO WOO D-FI LLED 2x ALUM NUM LEDGER TABLE 3D - FASTENERS REQUIRED AT CONNECTION OF HANGERS PER DETAILS 9, 11, AND 12/S4.4 TO EXISTING WOOD -FILLED 3xALUMINUM LEDGER TRIB WIDTH 10 PSF LL/GSL 20 PSF LL/GSL 25 PSF GSL 30 PSF GSL I 36 PSF GSL 40 PSF GSL 42 PSF GSL 50 PSF GSL 60 PSF GSL 72 PSF GSL 84 PSF GSL 5' A-16"oc A-16"oc A-16"oc A-16"oc A-16"oc A-16"oc B-16"oc C-16"oc A-16'oc B-16"oc C-16"oc G A-16"oc A-16"oc A-16"oc A-16"oc B-16"oc C-16"oc C-16"-oc C-16"oc B-16"oc C-16"oc D-16"oc 7' A-16"oc A-16"oc A-16"oc B-16"oc C-16"oc C-16"oc C-16"oc C-16"oc C-16"oc D-16"oc C-12"oc B' A-16"oc A-16"oc B-16"oc C-16"oc C-16"oc D-16"oc C-12"oc I C-12"oc D-16"oc C-12"oc D-12"oc 9' A-16"oc B-16"oc B-16"oc C-16"oc D-16"oc C-12"oc C-12"oc B-12"oc C-12"oc D-12"oc C-8"oc 10' A-16"oc C-16"oc C-16"oc D-16"oc C-12"oc D-12"oc D-12"oc C-12"oc C-12"oc B-8"oc C-8"oc 11' A-16"oc C-16"oc C-16"oc C-12"DC C-12"oc D-12"oc B-8"oc C-8"oc D-12"oc C-8"oc C-8"oc 12' A-16"oc C-16"oc D-16"oc C-12"oc D-12"oc C-8"oc C-8"oc 1-8"oc B-8"oc C-8"oc D-8"oc A - 1/4" LAG SCREWS B - 5/16" LAG SCREWS C- 7/16" LAG SCREWS D -1/2" LAG SCREWS ALL FASTEN ERS TO HAV E 3" P EN ETRATI ON 1 NTO WOOD-FI LLED 3x ALUM[ N UM LEDGER USE (2) FASTENERS FOR LL/GSL UP TO 50 PSF. USE (3) FASTENERS FOR LL/GSL=51 PSF AND ABOVE TABLE 4-ANCHORS INSTALLED INTO THE SIDE OF 6 IN THICK MIN CONCRETE OR CMU WALLS LL/GSL = 84 PSF MAX IN CONCRETE, USE (2) ROWS OF 1/2" DIA SIMPSON STRONG- BOLT 2@32"OC,STAINLESS STEEL, WITH 3" MIN EMBED, STAGGERED, INSTALLED PERICC-ESR-3037. IN CMU, USE (2) ROWS OF 1/2" DIASIMPSON WEDGE -ALL @ 32" OC, STAINLESS STEEL, WITH 3 3/8" MIN EMBED, STAGGERED, INSTALLED PER ICC-ESR-1396. USE 3" SQ.xl/4" STAINLESS STEEL WASHER WHEN INSTALLING NEW WOOD LEDGER AGAINST EXISTING CONCRETE WALL 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 }FEss I0 ! co S 58 5 P Tq�F OF CA01��� DATE SIGNED: July 8, 2019 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949,305.1420 . �aPR�n m V ES TM EXPIRES ON: JUNE 30, 2020 REVISIONS MARK DATE DESCRIPTION 4 STEL JOB 9 DA02-02 DATE 07/0a(l9 DRAWN BY RC CHECKED MDS IAPM0195 V 3.1.1 SOLID PANEL STRUCTURES: ATTACHMENT TO EXISTING BUILDING S6.1 W.Lo&aE CLEAR DIMENSON 10 TEAM SEE TABLE 18 ON S6.1 R44GM PER 9, 11, OR 12/S4.4. FASTENERS PER TABLE 38/S5.1. (3) Yz"D RILL744�� 3 x 8 WOOD FILLED LAG MUS PEMPATION IROOF BRAT cONT. TRUSS TOP PER 6/SC5 OR WAFTERS )SSC SCUD PATIO CD�FR[� EWS1FFFAEDW/-2T PENETRATION 6 (E) BLOMNG BETWEEN CONT. RAFTERS OR TRUSSES, WHERE ODOURS (WLL SEE A (E) DUNE TRUSS TOP CHORD OR t4mRAFTERS @ 24 OC RAFTER OR TRUSS WOLPM omT'. 64 MIN 41-0" WX 1. EXSTING ROOF DESIGN LOADS RBL = 3 PSF (MIN) TO 8 PSF (MAX) Z NEW PATIO DESIGN LOADS: GSL = 50 PSF MN( 3. PLACE "SKA FLEX' OR SIMILAR MATMA. BETWEEN BZALT4=T AND COMPOSITE SHINGLE ROOFING TO PRDADE SEAL 4. £RACKET MUST BE CRE NTAO TCWATi6 ROOF EDGE AS S- M•L 5. USE 1HS DETAIL WITH IS1CF BW00 PER 6%54.5 A40 TABLES 1 AND 19 ON S6.1. & MaQ15L LEG OF BST SHALL SE LODW ;r MAX FROM FACE CF YALL ON ETHER SIDE OF WALL. O CONNECTION TO TOP OF EXISTING ROOF 50 PSF MAX. _ALLOMBLE CLEAR TIL VEM TO BEAM D?0' SEE TABLE to ON S5,1 SEE TABLE 1 2 x BYZ OR 3 x 8 WOOD ON 56.1 FILLED AUJANUM LEDGER I VNNGER PER 9, 11, OR 12/S4.4. FASTENERS PER TARE 39/S&l.. y / SOLID PATIO CWER- L TACT ALTFFd•14TNE ROOF E BRACIEE OPoENTATICN 3 x N3 WOOD FILLED x GT WOOD FILLED A_UMNJM LEDGER fr2 ALUMINUM LEDGER Wry OCCURS� WHERE ODCURS DECK/ v? DIRECI DU OC7' C" < < < < COLUM x'IS H N BEAM E W4NGER TO LII]GER OONNEC110N ROOF T PER 5/S4.5 (3) V-0 RAG -THREADED LAG SCEEINS W/- 1-V PENETRATION (3) )J6 RJLL-Tl ffEA LPG SORDID W/ 4" PENETRATION INTO (E) COAT. TRUSS TOP CHORD OR RAFTERS NOTE OFFSET FAS04ERS 3" MIN. IN HORIZONTAL DIRECTION. OF THE DM14G WOM WILL- 1. WHEN CONNECTING TO AN D05TING BALDING WALL WITHOUT OPENINGS, SITE -SPECIFIC ENGINEERNG IS REQUIRED TO VERIFY ADEQLWLY CIF THE TDasnNG STUD WALL FRAMING W-I N THE PATIO COO PROJECRON IS WIDER THAN THE MAX PROJECTION SHOWN IN THE FOLLOWING TABLE. 2- WHEN CONNECTING TO AN EXSTING BALDING WFIE7E AN OPENING IS PRESENT UNDER THE ASTADF6IENT OF THE PA710 TO THE EAVE OR THE WALL, STEE SPEaFIC ENGINEERING IS Rc-OU IRED TO VERIFY ADEQUACY OF THE MNG STUD WALL FRAMING (INOIAJDIN0 On SSZE� *EN TINE PA110 MEJT PROJECTION IS WIDER THAN THE VAX PRO.IECTION SHDAN IN RE FCEiONNG TABLE CR WHEN THE FASTING OPENING IS WIDER THAN THE MAX OPENING WIDTH SHOAN IN THE POLLOWNG TABLE 3 NO ADDMCNAL SITE SPECIFIC ENG INEERNG IS REQUIRED WHEN D35nNG OPENINGS / PRajE>rnONS ARE BOTH SMALLER THAN THOSE STATED ABU& TABLE 1- CRITERIA TO VERIFY THE NEED FOR SITE -SPECIFIC ENGINEERING N1AxMPROJECTION OPENING LENGTH WIDTH kLL/GSL 18'-a' 8'-0' 14'-0"E-0" 1T-a' 4'-0" 1a-0" 3'-0" 1 W-O' 2'-0" 4" MIN. (E) BDCIKNG BETWEEN OONT. RWIES SCREW EDGE DISTANCE OR TRUIS.SES, WHERE ODOURS MIN FACE 0r LFAGFR NOTE (E) CONT TRIES TOP CHORD OR RAFTERS @ 24 OC j EAVE OH L T1D PhFTER OR T1RU5S 5%37A1 247 MAX 'r 64 MN 4-( WY 1. EXSTING ROOF DESIGN LOADS ROL = 3 PSF (MN) TO 8 PSF (MAX) Z NEW PATIO DESIGN LOADS: LL = 10 PSF MAX (NO SNOW LOAD) 3 RACE "SKA FLDC OR SIMILAR MATER& BETWEEN BRACKET AND CONE SHNGLE ROOFING TO PRDADE SEA. 4. USE ALTERNATE BRACKET ORIENTATION W-EN D S 11'. 5. USE THIS DETAIL WITH ROOF BRACKET PER 5/S4S AND TABLE 1 AND 1A ON S6.1. C CONNECTION TO TOP OF E XIS11NG ROOF BEAM COLUI UIKtL;I IUN PAN 1 BEAM CONNECTION TO HOUSE NTS (E) STUD WALL r 3" x B" x 0.04f HEADER (3) N-0 LAG SCREW, o TYP. SEE NOTE 4 0 t CONC. WALL & NOTE i 1n (3) #14 SMS 5 @ CMU WALL !! EA. SIDE TRIBUTARY x I AREA MIN, i� 0 1" THICK MAX LATH ANO t �I PLASTER OR WOOD SIDING OR ----1,--2•_AR-3.-COATS_.OF-STUCCO- =.3'.x 8" RAFTER_ SEE NOTE 6 BRACKET 1, USE OF THIS DETAIL IS UM1(ED TO THE F17LLO ING ECR LL/GSL = 10 P5F MA]( IRB AREA TO COR ECEICN - 100 FT-2 BUTARY FOR U./GSL - 2D OR 25 PS TEaB AREA 10 OOM>ECIiON = 55 FT' FCR GSL = 30 PSF, MAC( TREE AREA TO M ECIION - 45 W FOR GSL > 30 Px DETAIL IS NOT PIJ.OWED 2 SEE PLAN FOR DEFINITION OF TRIBUTARY AREA }R 3. CBDw R � WITH LDaSBNWM. G FULL RIGHT L SRJD. NO OPENNG ALLOWED 4. USE (2 36" HILLY K&iZ W/ 4 OW Q� COI C VKL W/ 6' SPACING. 5. USE ITALL EST & (2) W H01 K13-3 W/ 4 0A0 @ CMU WALL W/ S SPACING 6. RywoOD sFEATFING DOES NOT mm Taw THIS 1" MAX. FASTENERS, SEE TABLES 34 & 4 ON S6.1 AND NOTE 1 (E) 1` THICK MAX LATH AND S44 PLASTER OOD SIDING/1, 2, HANGER PER OR 3-COAT STUCCO SOLID COVER SEE NOTE 2 (E) 2 x WOOD STUD WALL SIM AT CONCRETE, BRICK OR MASONRY WALL SEE NOTE ABOVE FASTENER PER S3.2 J NQ1ES 1. FASTENER TO BE INSTALLED AT CENTER OF (E) WOOD SRAS Z PLYWOOD SHEATHING DOES NOT COUNT TOM THIS V MAX 3. DETAIL IS VALID WITH Od'EORON TF%tT" (E) WOOD LEDGER ALONG SERUCVU E PROADED THAT THE M4MU M FASTENrDR PETE1f7A110N IN WALL STUDS PER TABLE 3%/S6.1 IS SATISFIED. f.,� WALL CONNECTION - - SIMPSON A34 - SEE TABLE "D" SEE TABLE 1 ON S6. BLOCKI BEIWEEN 2 ON S6.1 FOR 9 fI315 MINT, RAFTERS OR MID NUMBER OF A34s FM SIMPSON A35 - SHE TABLE 2 TRUSSES WHERE OCCURS ON S6.1 FOR SCREWS AND NUMBER OF A35s TEDD. HANGER PER S4.4. RASfFNERS PER TABLES ON S6.1. SEE NOTES 2 AND 3 ii. SOLD PAT IO ( E) WILL (� (E) CONE TRUSS OR SEE NOTE ABM RAFTERS @ 24 OC DaSTING FASCIA PLYWOOD SHE4IHNG BOAJLI Mr RE OOOUIRS NiOMIIBE 0DR p$OW M BEAM (E) EAVE OH RATER OR TRAS SCUM S& TABLE 1 ON S6.I 24 MAT[ 4 MIN NM 1. EXISTING ROOF DESGN LOAD& RDL = 3 PSF (MIN) TO 8 PSF(MAX) J4..L QL - 10, 20. 25, 30, 40 OR 50 PSF 2 FASTENERS TO EE LOCATED 4 MN FROM SPLICE IN (E) FASCIA BOARD AND 2" CLEAR FRAM TOP AND BUM M CF FA934 IM. 3. FOR E%TFdM SWVEL 1304MRS. SE DETAIL 6 CN S4.4. FOR FWPWf IS PER 9, 11 OR 12 ON S4,4, SEE TABLE 39 ON S6.1 2 x 6V x .024" RAFTER SEE TABLE FOR FASTENER TO RAFTER AND FASCIA #14 S.M.S. TOP & BOT 2 x 6V2 ALUM. (2 TOTAL) AT EA RAFTER BRACKET RAFTER TAIL OPTIONAL LATTICE GUTTER TUBE ROOF PANEL @24" O.C. MAX r #14 SMS @ 12" OC T&B WTI- !_ "L° SEE TABLE FASTENERS "L7 `D, WITH LATTICE 7 NO LATTICE To- v (4) #10 (3) #8 2'-0` 1° (6) #10 (4) #8 3' 0" 2" (12) #10 (2 ROWS OF 6) (8) #8 (2 ROWS OF 4) NOTE: 1. THIS DETAIL IS UMTTED TO 30 PSF MAX LL/GSL 2. FASTENER SPACING = 3/4" MIN DRAFTER TAIL TO GUTTER 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 r7FESS l ( YUCY1k''~ �,ti/� OF CA��F// DATE SIGNED: July 8, 2019 it 26030 ACERO, SUITE 200 MISSION VIEJO, CA92691 949.305.11501 FAX 949,305.1420 EXPIRES ON: JUNE 30, 2020 REVISIONS 1 MARK I DATE DESCRIPTION 4 STEL JOB # DA02-02 DATE 07108119 DRAWN BY RC CHECKED MDS IAPM0195 V 3.1.1 SOLID PANEL STRUCTURES: CONNECTIONS DETAILS S6.2 CONNECTION TO EXISTING ROOF A CONNECTION TO EDGE OF EXISTING RDOF 8 NOT USED SCALE NOTCH RETURN PORTION OF THE TOP FLANGE OF THE BEAM (AND INSERT WHERE OCCURS) AT CONNECTION TO COLUMN 3 x 8x0.4 2 BEAM OR 3" SQ. STEEL BEAM e (3) %"0 THRU-BOLTS @ B6, 87 OR E18 (6) -#14 SOS @ E. SIDE (2) %`0 THRU-BOLTS @ 93 TOP & BOT TOTAL = 24 I BEAM 83, 86, B7, a OR B8 PER S4.1 NOTCH FULL BOTTOM FLANGE OF I BEAM (AND INSERT WHERE OCCURS) ON ONE H BRACKET PER 1/S4.5 SIDE OF WEB AT CONNECTION TO COLUMN OR 1/1-4.3 3" OR 4" SQ. STEEL POST PER S4.3 ALUM. OR STEEL POST NOTE' DO NOT NOTCH BEAM AT END COLUMNS WITH OVERHANG NOTES: THIS DETAIL IS TO BE USED AS AN ALTERNATE TO DETAIL 3/S6.3 I BEAM TO POST 'H' BRACKET TO POST o BEW 81 OR 84 OPTIONAL SEE NOTE 1 1 2" MAX SPLICE DECORATIVE FASCIA WHERE OCCURS (WOOD, ALUM., (6) #14 SMS @ EACH (INT COL ONLY) OR HARDBOARD) HEADER TO COLUMN (4)#14 0C S.M.S. (12) FASTENERS PER DOUBLE BEAM B9, CONNECTION BID, B12, B15 OR 816 10 5/8"0 HOLE WITH II (4)#14 SMS EA SIDE PLAS ICTYPU PLG,AS l II REQ'IS * ACCEPTABLE TO I� ffi U BRACKET PER 4/54.5 USE ONE HOLE 3° SQ POST INSTALL SEE NOTE 2 SEEVERAL SCREWS, I a II 01 TYP. I N (2)#14 SMS EACH I I NOTES: SIDE T&B @32" I I ARCHITECTURAL SIDE 1. USE SIMILAR DETAIL AT 3 x 3 OR 3 x 8 BEAMS. ❑.C. PLATES, WHERE OCCUR, 2. U BRACKET IS NOT REQUIRED IF SIDE PLATES PER 3/S6.3 SHALL STOP & FLUSH OR H BRACKET PER 1/S6.3 ARE PROVIDED. BELOW BEAM 3" OR 4" SO. POST SEAM TO POST � DB! BERM TO COL __ 3" WIDE BEAM TYP B2, B5, 811, B13 OR B14 1 2" MAX SPLICE 3° OR 9' BEAM (6) #14 SMS EA. SIDE WHERE OCCURS SMS PER EVATION nP AT SIDE PLATE SP3 [(INT COL ONLY) (8) #14 SMS EA. SIDE c "0 PLASTIC PLUG TYP. AT SIDE PLATE SP4. SEE NOTE 1, ie tI Q PROVIDE FULL BEARING OF e e v BEAM ON POST. R a ua I p I Tn %uO HOLE WITH PLASTIC PLUG, AS CD CD REQ'D, TYP. IT IS ACCEPTABLE TO S DE PLATE EA SIDE USE ONE HOLE TO INSTALL SEVERAL SCREWS, TYP. r 3 POST (2) #14 SMS EA SIDE AT QV' SIDE PLATE EA. SIDE, SEE SDEM BOTTOM AND AT 32" OC MAX. TABLE 1 ON S1.x OR L1.x PLA SECTION OPTIONAL STYROFOAM INFILL OF 3" SO. POST BETWEEN A3 ELEV ELEVATION -- SIDE PLATES CAN STOP BELOW SIDE PLATES THE CONNECION BEAM TO POST CONNECTION NOTES: AT SCREWSCREWS BFLAT INTOUMN THE PORTIONUST / VERTICAL WALL OF BEAM ij 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 �FE551� f S585 OF CA0. DATE SIGNED: July 8, 2019 0,o-d;lllII A 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 �aPpppp IYIo OTM ES EXPIRES ON: JUNE 30, 2020 REVISIONS MARK DATE DESCRIPTION 4 STEL JOB # DA02-02 DATE 0710tu19 DRAWN BY RC CHECKED MDS IAPM0 195 V 3.1.1 SOLID PANEL STRUCTURES: CONNECTION DETAILS S6.3 STEEL POST STEEL INSERT PER 4/S7.2 AT POST TYPE C7, C8, & C9 ADJACENT �{ BOLTS PER TABLE 2 GRADE T1P.---7 " • �• z PER 4/S7.2 • a o x� a N w �.Y POURED " CONCRETE NOTES: IN BEAM SPAN TABLES 1. THIS DETAIL CAN BE USED FOR STEEL POST TYPES C6, C7, C8, OR C9. 2. THIS DETAIL SHALL NOT BE USED FOR ALUMINUM POST TYPE C1 OR ALUMINUM POST TYPES C2 OR C5. 3. IT IS ACCEPTABLE TO EMBED THE STEEL POST DIRECTLY INTO THE FOOTING PER 5/S7.1 INSTEAD OF USING THE POST SLEEVE SHOWN IN THIS DETAIL 4. THIS DETAIL CAN BE USED ON A SLAB ON GRADE PER 8/S7.1 AND PER TABLE 2 ON S7.1. 5. THIS DETAIL CAN BE USED AT FREESTANDING OR AT ATTACHED STRUCTURES. STEEL POST SLEEVE CONNECTION TO CONCRETE FOOTING 1"IIr-a" ADJACENT GRADE TY N POURED CONCRETE 3" OR 4" STEEL POST. ' r a y 3'MIN. � z N TYP. oLd ti �- o " a G • N ti _ a m c �? •. /1f MUM-LL"wn 01%) SE FiG. SCHEDULE IN BEAM SPAN TABLES WO A36 THREADED ROD W/- NUT EA SIDE OF COL OR 14 REBAR, GR 40 MIN. SECURED IN PLACE NOTES: 1. THIS DETAIL IS TO BE USED FOR POST TYPES C10 & C1 1. 2. THIS DETAIL CAN ALSO BE USED FOR STEEL POST TYPES C6, C7, C8, C9. 3. THIS DETAIL SHALL NOT BE USED FOR ALUMINUM POST TYPES C1, C2, OR C5. 4. THIS DETAIL CAN BE USED AT FREESTANDING OR AT ATTACHED STRUCTURES. TABLE 2- ANCHORAGE SCHEDULE BRACKET DETAIL POSTTYPE FTG(IN) ANCHOR BOLTS (SEE NOTE 2) SEE NOTES AWM T I/S7.21 C1 SOG (21-3/8" dia w/ 1.7/B" embed AWMT 1/S7.2 - C1 ALL (2y3/8"dia w/2-7/8"embed AWM T 2/67.2 C2 SOG (2}3/8" dia w/ 1.7/8" embed 3 AWMT 2/S7,2 C2 ALL (2)-3/8"dia w/2-7/8"embed 3 ALUM T 2/57.2 CS SOG (2}3/8" dia w/ 1-7/8" embed 3 AWM T 2/S7.2 CS ALL (2y 3/8" dia w/ 2-7/8" embed 3 57CE> 7-. 3/$7.2 .. _C6_ SOG- _(2]3/8" dia w/ 1.7/8" embed. __ _ STEELT 3157.2 C6 1522" (21.3/8"dia w/2-7/8"embed 1.3.4 STEELT 3/57.2 I C6 524" (*1/2" dia w/3.1/4" embed 1,3.4 4/57.2 C6 530" (4)-117'diaw/3.1/4"embed 1,4,6 4/972 C6 534" {4]-5/8"dlaw/4"embed 1,4,6 E 4/57.2 C6 235" (4)-3/4'diaw/4-314"embed 1,4,6 4/S7.2 C7, C8, C9 ALL (4)-3/4" dia w/ 4.3/4' embed 1,5,6 nIS7.11 L10,01 ALL I I4IA NOTES: 1- "FTG (IN)- 15 THE FOOTING DIMENSION REFERENCED IN BEAM SPAN TABLES ON SHEETS S8.xxx 2 -ANCHOR BOLTS SHALL BE SIMPSON STRONG BOLT 2, STAI NLESS STEEL (I CC-ESR 3037). HILTI KB-TZ SS CAN ALSO BE USED WITH A4" SLAB, AND A REDUCED EDGE DISTANCE OF 3 1/2" (ICC-ESR-1917). 3- IT IS ACCEPTABLE TO USE TH E STEEL INSERT PER4/S7.2 INSTEAD OF THE ALUMINUM T PER 2/57.2 FOR POSTTYPES C2 AND CS OR INSTEAD OF THE STEELT PER 3/S7.2 FOR POSTTYPE C6. BOLTS CAN REMAIN AS SPECIFIED INTHISTABLE, BUT (4) BOLTS SHALLBE USED. SEE NOTE 6. 4 - IT IS ACCEPTABLETO USETHE EMBEDDED POST DETAIL5/57.1 INSTEAD OF THE STEEL INSERT PER 4/S7.2 OR STEELT PER 3/S7.2 FOR STEEL POSTS C6. 5 - IT 15 ACCEPTABLE TO USE THE EMBEDDED POST DETAIL 5/S7.1 INSTEAD OF THE STEEL INSERT PER 4/S72 FOR STEEL POSTS C7, C8 AND C9. 6 - HOLE SIZE IN BASE PLATE SHALL BE MAX.1/9" DIAMETER OVERSIZED, UNLESS WELDED WASHER IS PROVIDED. ANCHORAGE OF POSTS TO SLAB OR FOOTING 3" STEEL OR ALUMINUM POST t WIDTH - LENGTH IN SEE FIG. SCHEDULE I BEAM SPAN TABLE CENTERUNE OF "T" BRACKET TO BE PARALLEL TO HOUSE WALL "I" BRACKET PER 1/S7.2, 2/S7.2, OR 3/S7.2. BOLTS PER TABLE 2 ON S7.1 TABLE 1 ALTERNATE FOOTING DIMENSIONS FrG(IN) W-L=D - (SEE NOTE 1) Alt1 WxLxD (SEE NOTE 21 Alt2 WxLxD (SEE NOTE 3r - Alt 3(ATTACHED) WxLx18" - (SEENOTE 4)" Alt4 WxLx18" (SEE NOTES]-- Alt5 WxLx24" (SEE NOTE 6)- Alt6 WxLx30" (SEE NOIE-71=-' AIt7 WxLx36" "1SEE NOTE 8) :- Alt8 WxLx42" (SEE NOTE 9) 18 18x18x18 12x12x12 '18x18x18 18x18x18 16x16x24 14x14x30 13x13x36 12x12x42 20 20x20x20 12x12x12 21x21x18 25x25x18 19x19x24 17x17x30 15x15x36 14x14x42 22 22x22x22 16x16x16 25x25x18 33x33x18 21x21x24 19x19x30 17x17x36 16x16x42 24 24x24x24 20x2Ox2O 28x28x18 43x43x18 24x24x24 22X22x30 20x20x36 18x18x42 26 26x26x26 23x23x23 32x32x18 31x31x24 24x24x30 22x22x36 21x21x42 28 28x28x28 25x25x25 35x35x18 38x38x24 27x27x30 25x25x36 23x23x42 30 30x30x30 28x28x28 39x39x18 30x30x30 28x2Bx36 26x26x42 32 32x32x32 3Ox30x30 43x43x18 37x37x30 30x3Dx36 28x28x42 34 34x34x34 32x32x32 47x47x18 33x33x36 31x31x42 36 36x36x36 34x34x34 51x51x18 36x36x36 34x34x42 38 38x38x38 37x37x37 55x55x18 43x43x36 36x36x42 40 40x40x40 39x39x39 60x60x18 39x39x42 42 42x42x42 41x41x41 64x64x18 42x42x42 44 44x44x30 46 46x46x30 48 48 x 48 x 30 50 50x50x30 52 52x52x30 54 54 x 54 x 30 56 56 x 56 x 30 58 58 x 58 x 30 60x60x30 62 x 62 x 30 64x64x30 M 66x66x30 68 x 68 x 30 70 x 70 x 30 72 72 x 72 x 30 74 74x74x30 76 76 x 76 x 30 78 78x78x3D 80 80xBOx30 82 82x82x3D 84 84x84x30 86 86x86x30 88 88 x 88 x 30 90 90 x 90 x 30 GRADE TY'P. NOTES: 1-"FTG (IN)" ISTHE FOOTING DIMENSION REFERENCED IN BEAM SPAN TABLES ON SHEETS 58xx.x OR LS.xxx. 2 - "ALT 1" ISTHE FOOTING DIMENSION BASED ON THE "FTG (IN)- DIMENSION. NOTE THAT W=D=L 3 - "ALT 2" 15 THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN A 3.5" MIN THICK SLAB IS PRESENT ABOVETHE FOOTING. NOTETHAT W =D=L CONCRETE FOOTING 4 -'ALT3" ISTHE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPTTO AN 18" DEPTH FOR UPLIFT DESIGN ONLY.THIS VALUE IS TO BE USED ONLY AT ATTACHED PATIO STRUCTURES. NOTE THAT W d AND D=18". 5-"ALT4" ISTHE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING 15 KEPTTO AN 18' DEPTH. NOTETHAT WdAND D=18". 6 - "ALT 5" IS THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING 15 KEPTTO AN 24" DEPTH. NOTETHAT W=L AND D=24 7 - "ALT6" IS THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING 15 KEPTTO AN 30" DEPTH. NOTETHAT WdAND D=30". 8 - "ALT7" 15 THE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING IS KEPTTO AN 36" DEPTH. NOTETHAT W=LAND D=36". 9 - "ALT 8" ISTHE ALTERNATE FOOTING DIMENSION REQUIRED WHEN THE FOOTING 15 KEPTTO AN 42" DEPTH. NOTETHAT W d AND D-42". NOTES: 1. THIS DETAIL CAN BE USED WITH POST TYPES C1, C2, C5, OR C6. 2. THIS DETAIL SHALL NOT BE USED FOR FREESTANDING STRUCTURES. 3. THIS DETAIL SHALL NOT BE USED FOR POST TYPE C7, C8, C9, C10, C11. 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 DATE SIGNED: July 8, 2019 V 1�41 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.1150 1 FAX 949.305.1420 N ! TM EXPIRES ON: JUNE 30, 2020 REVISIONS MARK DATE DESCRIPTION 4 STEL JOB # DAD2-02 DATE 07108119 DRAWN BY RC CHECKED MDS IAPM0195 V 3.1.1 SOLID PANEL STRUCTURES: FOUNDATION DETAILS 6 STEEL POST EMBEDDED INTO CONCRETE F007ING T BRACKET CONNECTION TO CONCRETE FOOTING 1"=1'-o' 8 FOl1NDATIDN TABLES S7.1 TABLE 3 - (MAX WIND SPEED: 130MPH, EXP C) MAXIMUM POST SPACING WHEN PATIO COVER IS INSTALLED ON SLAB ON GRADE ROLLED FORMED PANS (RF) IRP TRIB WIDTH LL/GSL(psf) GSL(psf) LL/GSL(psf) 10 psf 20 psf 25 psf 30 psf SO psf 20 psf S. 13'-7" 11'-0" 10'-4" 9'-0" 12'•6" 10'-0" 6' 11'-4" 9'-9" 9'-0" 8'-4" 10'-5" 8'-9" 7' 9.4. 9'-0. 8'-0" T 6• 9' 0" W.O. 8' W-6" 8'-6" 7'-6' 7'-0" 7'-10" 7'.6" 9' 7-7" W-0" T-0" NP 7'4' T-O" 10, 6'-9" T-6" NP NP 6'-3" 6%6" 11' 6'-2- 7'-0" NP NP 5'-8' 6'.0' 12' V-8" 6'-6" NP NP 5'-3" V.6" NOTES: 1 -"NP" INDICATES THAT A FOOTING 15 REQUI RED, AND THE PATIO COVER CAN NOT BE SUPPORTED ON ASLAB ON GRADE. 2 - FOR LIVE OR SNOW LOADS HIGHER THAN THE ONES SHOW N ON THIS TABLE, A FOOTING IS REQUIRED AND THE PATIO COVER CANNOT BE INSTALLED ON SLAB ON GRADE. TABLE 4 - (MAX WIND SPEED:130MPH, EXP C) MAXIMUM TWO POST ATTACHED STRUCTURE WIDTH WHEN PAT10 COVER IS INSTALLED ON SLAB ON GRADE TRIB WIDTH ROLLED FORMED PANS (RF) IRP LL/GSL(psf) GSL(psf) L1/GSL(psf) (ft) 10 psf 20 psf 25 psf 30 psf 10 psf 20 psf 5 27'-2" 22'-0" 20'-B" 18'-0" 25'-0" 20'-0" 6 22'-B" 19'-6' 18'-0" 161 21'-0" 17-6" 7 19'4' 18'-D' 16'-0" 3.5--0" 18'-0" 16--0" 8 v'-0" 17'-D" 15'-0" 14'-0" 15'-8" 15'-D" 9 15-2" 16'-0" 14'-0" NP 14'4" 14--0" 10 13'-6" 15'4" NP NP 12'-6" 13'-0" 11 12'-4" 24--0" NP NP 11'4. 12'1" 12 11'4" 13--0" NP NP 10'-6" E T BRACKET CONNECTION TO SLAB ON GRADE 1"=1'-O" Oo OoJ.ASTM A5DG GRADE 8 O O NSERT TO PLAN 3�y BASE PL -�-3" STEEL POST 0.188" THICK MIN HSS INSERT 5) Y4"0 BOLTS 0" SQ. x %" BASE PL NOTES ELEVATION a g 1. THIS BRACKET IS TO BE USED WITH POST TYPE C7, C8 & C9, AND WITH C6 (WHEN FOOTING SIZE IS 25" OR LARGER). 2. SEE TABLE 2 ON S7.1 FOR ATTACHMENT TO FOOTING/SLAB. 3. INSTALL IX x 14 06 HDG WELDED WASHER PLATE WHEN HOLE DIAMETER IS MORE THAN Ye" BIGGER THAN ANCHOR BOLT DIAMETER. 4. THIS BRACKET CAN ALSO BE USED FOR POST TYPE C2, C5, OR C6 (ALL FOOTING SIZES) SEE TABLE 2 ON S7.1 AND 7/S7.1 FOR ANCHORAGE REQUIREMENTS. (�)STEEL POST SLEEVE FOR POSTS CS, C7, CS, C8 3•=1'-0" 3" STEEL OR CENTERLINE OF "T" ALUMINUM POST BRACKET TO BE PARALLEL PirTO HOUSE WALL ADJACENT GRADE ! 7' BRACKET PER 1/S7.2, WHERE OCCURS I 2/S7.2 OR 3/S7.2 EXISTING OR NEW SLAB ON GRADE. f c = 2,500 PSI MIN. i i rMIN, ! SEE NOTE 6 '71 EDGE OF SLAB BOLTS PER TABLE 2 ON 4/S7.1 WHERE OCCURS NOTES: 1. THIS DETAIL CAN BE USED WITH POST TYPES C1, C2, C5, OR C6. 2. TABLES 3 AND 4 IN THIS DETAIL CAN BE USED FOR FREESTANDING STRUCTURES AND/OR COMMERCIAL APPLICATIONS, BUT THE STRUCTURE CANNOT BE INSTALLED ON A SLAB ON GRADE AND REQUIRES A FOOTING PER SB.xx.x. 3. THIS DETAIL SHALL NOT BE USED FOR POST TYPE C10 & C11. 4. SEE "SLAB ON GRADE USED AS A FOUNDATION SYSTEM" NOTES ON GOA FOR MINIMUM OVERALL DIMENSION OF SLAB AND ACCEPTABLE CRACKING AND CONTROL/EXPANSION JOINTS CRITERIA 5. WHEN THE PATIO COVER IS INSTALLED ON A SLAB ON GRADE (RESIDENTIAL APPLICATIONS ONLY), THE MAXIMUM POST SPACING IS THE LOWEST OF THE 'MAX POST SPACING (SPAN)" SHOWN ON S8.XX.1 AND THE MAXIMUM POST SPACING SHOWN IN TABLE 3. 6. SEE NOTE 2 ON 4/S7.1 FOR ALTERNATE 7. THIS DETAIL CAN ONLY BE USED IN AREAS WITH A FROST DEPTH EQUAL TO ZERO. B. SEE "GENERAL NOTES - SLAB ON GRADE USED AS A FOUNDATION SYSTEM' NOTES ON GOA FOR MORE INFORMATION. ALUM ALLOY 6063-T6 2 OR TEK I�-�I OR TEK SCREWS, EA. SIDE, TYP. 0 0 %110 HOLE EA SIDE i G.085 TYP. i 0.750" 5.662" 1TYP. NOTES: 1. BRACKET LENGTH IS 2.75" 2. THIS BRACKET IS TO BE USED WITH POST TYPE C1, WITH OR WITHOUT SIDE PLATES PER SP3 OR SP4. 3. SEE TABLE 2 ON S7.1 FOR ATTACHMENT TO FOOTING/SLAB. 4. INSTALL 1Y4 x 1Y x Ye HDG WASHER PLATE AT ANCHORS FOR 130 MPH ALUMINUM T BRACWr FOR POST Ct 3"=1'-D" ALUM ALLOY 6063-T6 4-#14 SMS ' dnF'1 OR T SCREWS, {ICI EA. SIDE, TYP. Ui I I %"0 HOLE EA. SIDE I 0.094" TYP. i 0.750" 5.50" TYP. NOTES: 1. BRACKET LENGTH IS 2.75". 2. THIS BRACKET IS TO BE USED WITH POST TYPE C2 OR C5, WITH OR WITHOUT SIDE PLATES PER SP3 OR SP4. 3. SEE TABLE 2 ON S7.1 FOR ATTACHMENT TO FOOTING/SLAB. 4. INSTALL 1h x 1h x Jb HDG WASHER PLATE AT ANCHORS FOR 130 MPH. 5. STEEL T-BRACKET PER 3/S7.2 CAN BE USED IN LIEU OF THIS BRACKET. AUMINUM T-BRACKET FOR POSTS _ Cz C5 3"=V-O" 0.75' 4.00" 1 ASTM A500 GRADE B TYP 1,75' 4-Wfi'0 HOLES D D 1-/Is"0 & 2-W5" c�,,' D 21 - �Cf- - HOLES, TYP EA SIDE 0 D O D CENTERLINE OF i BRACKET TO PLAN 200� BE PARALLEL TO 3.50" 1.ow HOUSE WALL T1P # t' 2-7/fs"O HOLES FOR o go M.B. TYP. N U, N CV 4 ELEVATION NOTES: 1. THIS BRACKET IS TO BE USED WITH POST TYPE C6 WHEN FOOTING SIZE IS 24" OR SMALLER, WITH OR WITHOUT SIDE PLATES PER SP3 OR SP4. 2. BRACKET CAN ALSO BE USED WITH POST TYPE C2 OR C5 PER TABLE 2 ON S7.1 AND 2/S7.1 3. SEE TABLE 2 ON S7.1 FOR ATTACHMENT TO FOOTING/SLAB. STEEL T-BRACKET FOR POST co 3"=1'-0" 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 o[1FESS 1 / S 5$ 5 J T �rE OF CANE DATE SIGNED: July 8, 2019 17 26030 ACERO, SUITE 200 MISSION VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 �APpppp lY! o OTM ES EXPIRES ON: JUNE 30, 2020 REVISIONS MARK DATE DESCRIPTION 4STELJOB I# DA02-02 DATE 070H9 DRAWN BY RC CHECKED MDS IAPM0195 V 3.1.1 SOLID PANEL STRUCTURES: FOUNDATION DETAILS S7.2 ATTACHED & FREESTANDING SOLI COVERS - 10 PSF`SNOW LOAD OR LIVE LOAD -110 MPH - EXP. B & C 86.5" ROLLFORM 8 MAG BEAM s $3 4" I -BEAM 64 4.5" MAG GUTTER 65 12 GA S L"UALCHANNEL BB 7" I•BEAM ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED 1 FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING TRIB WIDTH WIND EXP MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST 'TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN ' POST TYPE 5 110 B 110 C 1 V-9" 11'-9" 18 20 Cl 11'-9" 1V-4" 26 28 C7 10-4" 10'-0" 17 19 Cl 9'-0" 9'-2" 25 26 C7 13'-7" 19 Cl 12' 4" 27 C7 13'-3" 19 Cl 12'-7' 27 C7 13' 4" 19 C1 12'-10" 27 C7 23'-0" 22 - 21'-S' 20'4' 31 33 C7 13-T' 21 12-1" 28 13'-3" 21 11'-5' 28 12'_3' 20 1.710" 28 23'4" 25 6 110 B 110 C 10'-9" 10'-9" 18 21 Cl 10'-9' 10' 4" 26 27 C7 9'-9" 9'-9" 18 20 C1 V-19' 8Ht° 24 26 C7 12'-9 12'-9" 19 22 C1 11'' 8" 26 C7 12'-2" 19 Cl 11, 26 C7 17-7" 19 Cl 11'-0 26 C7 22-0 23 — - 20' 0" 19'fiC5 - 30 32 C7 11'-0" 2B 17-2' 27 11'-7' 28 11'-3" 21 11'�1 28 22'-0 26 T 11UB 110 C 10'-0" 10'-0" 19 21 C1 10'-0" g,-0" 26 C7 9'-3" 9, 3„ 18 21 Cl 8'-0" B-0, 25 26 C7 12'-2 20 Cl 11'-1" 26 C7 11'-3" 20 Cl 10'-1U 26 C7 12-0" 20 Cl 11'-0" 26 C7 2D-10" 24 � 19'-0" 18-7" 30 32 C7 12,_2 23 10,_9„ 27 11,-3 10, T, 27 10'4" 21 1U 2 � 20, 70" 27 8 110 B 110 C 9'�" 9�" 19 22 Cl 9 4" 9.7" 26 26 C7 8'-10" 8'-10" 19 21 Cl B'-2 7'•10 25 25 C7 11'-B" 11' B" 21 23 C2 10'-7" 27 C7 1 U-7" 20 C1 1014, 27 C7 11'-0" 21 C2 1 D'-6" 27 C7 2U-1" 25 CS 18'-T 1T-9" 31 31 C7 10'�" 27 10' 7 23 10'-7' 27 9'-9" 22 9' 7 27 20'-1" 28 9 110B 110 C 8-10 8'-10" 20 22 Cl 8-10" 8' 7 27 26 C7 B'-7' 8'7 19 22 Cl T' 26 C7 11'-1" 21 C2 10'-2" 28 C7 10'-0" 20 Cl 10'-0" 27 C7 11'-0" 21 C2 1D'-1" 26 C7 19'-7' 25 17'-0 1T-1" 32 32 C7 T 7 26 i i'-1" 24 10'-0" 27 10'-0" 23 9'-T' 27 9'-7' 22 9'-0" 27 i9 7' 28 10' 11 D B 11DC B'-0 20 23 Cl B'-0 H'-1" 27 27 C7 8'-3" 8'-3" 20 22 Cl 7' 7" 26 C7 10' S 22 C2 9'-10" 28 C7 9'-0" 21 C2 9-0 26 C7 1 D'�" 21 C2 S 9" 28 C7 18'-3 18'•3" 26 29 16-10" 16'6 32 32 CB T4' 27 10'-0" 24 9'-T' 28 9'-8" 23 9'-2 28 8'-9" 23 6'-7" Z7 11' 11D B 11DC 8'-1" 8'-1" 21 23 C2 6'-1" 7'-9 27 28 C7 6'-0" 6'� 20 23 Cl 7'-4" 7'-7` 27 26 C7 10'-0" 22 C2 5'-7" 29 C7 9'-1" 21 C2 9'-1" 28 C7 9'-10`1 22 C2 9'-0" 29 C7 1T�" 17'4" 26 29 C5 16'�" 18'0 33 33 Co 1D'-0" 25 9'-3" 2B 9'-1" 24 9'-5' 28 8'-0" 23 8'-2" 28 12' 110 B T4" 21 C2 7-8" 28 C7 T-7 21 C2 7'-2" 27 C7 9'-7" 22 C5 9'-3" 29 C7 8'-8" 21 C2 8'-B" 29 C7 9'-0" 22 C2Lj 9'-2" 29 C7 16'-8" 27 C5 16'-0" 15' 7" 34 33 Co 134 C T-0 24 T-6" 28 7,. 23 7.-0 9'-T' 25 9'-1" 29 B'_8" 24 6.�.. 28 8, 0" 23 T 10" 28 18 8 3D B7 7"I-BEAMW/ "C" INSERT 68 7"I-BEAMW/ "C" INSERT DBL2x6.5xO.042 s B1p � DBL2x6.5x0.032 B11 tx8x0.042 812 DBL3x8x0.042 (1) (2) ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX IN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN TRIB WIND POST FTG POST POST FTG POST POST FTG POST POST FTG POST POST FTG POST POST FTG POST POST FTG POST POST FTG IPOST POST FTG POST POST FTG POST POST FTG POST POST FTG POST WIDTH EXP SPACING ON) TYPE SPACING (IN) TYPE SPACING (IN) TOPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING ON) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) 110B 26'-9" 23 24'�" 32 C7 29'-0" 24 26'-1D' 33 C8 16'-0" 20 16'-0" 29 13'-2" 19 1T-T 27 C7 13'8" 19 Q7 13'�" 27 C7 19'-T 21 C2 19'-31 30 C7 5 11D C 28-9" 26 CS 23' 8 34 CB 29'-0 27 C5 26'-7' 35 C9 16'-0" 22 Cl 15-3" 30 C7 12'-7' 21 Cl 12'-3" 29 12'-10 21 12'-T' 29 18'-i" 23 17 8" 31 110 B 25'-0" 24 23'-0" 31 C7 2T-9" 25 32 C7 14'-T' 20 14'W" 28 12'-1" 19 12'-1" 27 7e-6" 19 Cl 12'-0" 27 C7 1T7" 22 17-T' 29 C7 5 11D C 25'-3" 27 CS CS34 Cl C7 Cl C7 16'-1" 31 22'-0" 33 CB 2T-9" 28 CB 14'-T' 23 14'-0" 29 11'�i' 21 11'-T 28 11'-9" 21 11'-0 28 16'-0" 24 110 B 24'-D" 25 21'-9" 32 C7 254" 26 32 13'-T 21 13'-0" 28 11'-7' 20 11'-T 27 1V-7" 20 C1 11'-T' 27 C7 16'-3" 22 163" 29 C7 7 110 C 24'-T 28 C5 C534 CS 13'3" 23 C2 C7 Cl C7 15-0 30 21'-3" 33 CS 26'4" 29 13'-0" 29 10'-0" 22 10'4' 27 10'-10" 22 10'$" 27 15'-3" 24 11 D B 23'-0" 26 20'-10" 32 25'-3" 27 j24 33 12'-0" 21 12'-8" 28 10'�i 27 10'-10" 20 C1 10-1 D" 27 C7 1 S-3" 23 C5 15'-3" 30 C7 8 110 C 23'-0" 29 CS 20'-3" 32 CS 25'-3" 30 CS33 1 5-B" 24 C2 C7 Cl C7 14-1 " 29 12'-2" 2B --10'-6-2U 10-0„ 7� 9' 9 27 10'-7' 22 10�1 27 14'�" 25 110 B 22'-1" 27 2D'-1" 33 24'-3" 27 34 CB 12'-0" 22 12'-0" 29 9-10" 21 C2 9'-10" 27 1UZ 21 C2 10'-2" 27 C7 14'-4" 23 CS 14'�" 30 C7 110C 7Z-1" 30 CS 19'T' 33 CS CS34 C2 C7 C7 13-2" 30 24'-3" 31 C9 12'' T 24 11'6" 29 9'�" 23 Cl 9'-2 27 9' B" 23 Cl 9 4" 27 13W" 25 11013 21'4' 27 9'4' 19'�" 34 23' G' 21 2V41 35 11'-4" 22 1 V-4" 29 C7 C2 28 C7 13'-0 24 CS 13' 8" 31 C7 10, 110 C 21'�" 31 C5 1 33 C8 23'-6" 32 C5 20'-9" 34 C9 11'�" 25 C2 10'-10" 29 C7 9'-0" 23 C2 B'-9 27 9'-7' 23 8'-0" 27 12A0" 26 177" 30 1108 20'3" 28 1 B'-9" 34 22'-9" 29 20'-8" 35 1 D'-1 D" 22 10'-10" 30 9'-0" 21 9'-0" 28 B'-0" 21 C2 B'_4" 28 C7 13'-1" 2d C5 13'-1" $1 C7 11' 110C 20'3" 37 CS 18'-3" 34 C9 22'-9" 32 CS C9 CS C7 C2 C7 124. 30 20'-7' 35 1D'-10 25 1D'-0" 29 8'-T' 23 8'-0" 28 S'�" 23 T-a" 26 12'-3" 26 1108 20'-1" 28 18'-3" 35 22'-1" 29 20'-1" 36 10-0" 23 10 4" 30 B'-7" 21 S' T' 2B T3 21 C2 T-S" 2B C7 JZ; 24 C5 12'-' 31 C7 12' CS C9 CS C10 CS C7 C2 C7 11'-9 27 11'3 31 110 C 20'-1" 32 1T-9" 35 22-1" 33 19'-T' 35 1D' 4" 26 10'-0" 30 8'-2 23 8'-0" 2B 7'-8 23 T-1" 28 B13 14 GA STL INSERT 3 B14 12 GA STL INSERT V/ 6B 615 DBL14 GA STL INSERT Bib DBL 12 GA STL INSERTB18 N ERT 12 GA STL U-I/ D 619 12GASTL U--INS RT ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING TRIB WIDTH WIND EXP MAX POST SPACING (SPAN) FTG (IN) MIN POST TOPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TOPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TOPE MAX POST SPACING (SPAN) FTG (IN) MIN IPOST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG ON) MIN P057 TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TYPE MAX POST SPACING (SPAN) FTG (IN) MIN POST TOPE 5. 110 B 110 C 16'-0" 18'-0" 21 23 C2 18', 4" 17'3" 30 31 C7 20'-l" 2V-1" 21 24 C2 20'-1" 30 C7 25-10" 23 CS 25'-10" 32 CB 28'4" 24 CS 27'-8" 35 C10 25'-10' 23 C6 25'-10' 46 C10 32' -T 25 C6 32' 6" 49 C1D 19'-4" 32 25'-10" 26 24'-10" 34 28'A" 27 2T-0" 37 22'-11° 25 C6 22'-11' qq 28'-11" 27 C6 28'-li" 47 6 110 B 110 C 16'-7 16'-9" 21 24 C2 16'-9" 16'-2' 29 31 C7 I VA' 18'-4" 22 25 C2 I VA" 1T-8" 30 31 C7 23'-8" 24 CS 23'-8" 32 C8 25'-1 D" 25 CS 25'-1 T 34 C10 24'-3" 24 C6 24'-3' 46 C10 30'-7' 26 06 30' 7' 51 C1D 23-0" 27 22'-9" 33 25.10„ 27 24'-1D 36 21'-7° 26 C6 21'-7' 46 27'-2" 29 C6 27-T 49 T 110E 110 C 15-7" 15'-T' 22 24 15'-T' 15'-0" 29 3D C7 1T-1" 1T-1" 22 25 CS 1T-1" 16'�" 30 31 C7 24 CS 22'-0" 32 OB 24"{} 25 CS 24'0 34 C10 23'-1' 25 C6 23-1' 49 Cl0 29'-1' 27 C6 29-1" 53 C10 22'-0" 27 21'-1" 33 24'-0 26 23'1" 35 20' 6" 27 C6 20' 6' 47 25-1D' 29 C6 25'-SO" 51 8. 110B 110 C 14'-7" 14'-T' 22 25 CS i4'7" 14'A- 29 29 C7 16-0" 16'-0" 23 26 CS 16'-0" 30 C7 20'-T' 25 C5 20'7 32 CS 2T� 28 CS 22'-0 34 C10 22'-1" 25 C6 2T-1' S1 C10 27' 10" 27 C6 2T-10" 54 C10 15'�" 30 20'-T' 26 1 V-9" 32 22'-T 29 21' 7" 34 19'-7° 2B C6 19'-7' 49 24'-0' 30 06 24' W 52 g 11DB 110 C 13'-9" 13'-9 23 26 CS 13'-9" 13'-3" 30 3D C7 15'-1" 15-1" 23 26 CS 15%1" 31 C7 19'-0" 25 CS 194" 33 CB 21'-2" 26 C5 21'-2' 35 C10 21'-2" 26 C6 21'-2" 52 C10 26'-9" 28 C6 26'-9" 56 C10 14'-0 30 19'�" 29 16'-7" 32 21'-2" 29 20' 4" 35 18'-10' 29 C6 18'-10' 50 23'-9" 31 C6 23-9• 5d 10' 110B 110 C 1TA" 13'-1" 23 26 CS 13'-1" 12'7" 30 30 C7 14'-3" 24 CS 14'-3" 31 C7 16'4' 26 C5 18'�" 33 C8 20'-1" 27 CS 20'-1" 35 C10 20'-6' 27 C6 20'-6' 53 C10 26-10' 29 C6 25'-i0" 57 C10 le-S, 27 13'•9" 31 18'4" 29 17,3„ 33 20.7" 30 19'�" 35 18'-2" 30 06 16'-2° 51 22-11' 32 CS 22'-11" 55 11' 110 B 110 C 12'-0" 12'-0 24 26 CS 12'-0" 12'-0 31 30 C7 13'-0" 73' 8" 24 27 CS 13'-8" 13'-1" 31 31 C7 IT-T, 17'-T' 26 30 CS 17'T' 16'-1D" 34 33 C8 19'-2" 27 CS 19'-7' 36 CIO 19'-10° 27 C6 19'-10' 54 Cl0 25'-0' 29 C6 25'-0" 58 C10 19'-7' 3D 16'-0 35 17'-7° 30 C7 1TT 52 71'_2' 33 C7 22 7 r� IT 110 B 12'-0" 24 CS 12'-0" 31 C7 13'-1" 25 CS 13'-1" 32 C7 16'-9" 27 CS 16'-9" C9 28 CS 18' 4" 36 C10 1 T-3" 28 C6 19'-3' 55 C10 24'-3' 30 C6 24'-3" 59 C1D 110C 12'-0" 27 11'-S 31 13'-1" 28 12'-7" 32 16'-9" 30 16'-2" 34 18'-0" 31 1T-T 36 IT-1" 31 C7 17'-1' 53 21'7' 33 C7 21'7" 57 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 DATE SIGNED: July 8, 2019 1Z.1drh"i TCL 26030 ACERO, SUITE 200 MISSIONMEJO, CA 92691 949.305.11501 FAX 949.305.1420 EXPIRES ON: JUNE 30, 2020 I�f REVISIONS MARK RKI DATE DESCRIPTION 4 STEL JOB # DA02-02 DATE 07108/19 DRAWN BY RC CHECKED MOB IAPM0 195 V 3.1.1 SOLID COVER STRUCTURES: BEAM SPANS & FOUNDATION SIZES 10 PSF LUSL, 110 MPH NOTES: 1 -WHEN THE PATIO COVER IS INSTALLED ON A SLAB ON GRADE (RESIDENTIAL APPLICATIONS ONLY), THE MAXIMUM POST SPACING IS THE LOWEST OF THE "MAX POST SPACING (SPAN)" SHOWN ABOVE AND THE MAXIMUM POST SPACINGS SHOWN ON DETAIL 8/S7.1 2- IT IS ACCEPTABLE TO SUBTITUTE COLUMNS W/ HIGHER NUMBERS W/ THOSE SPECIFIED IN THE TABLES SHOWN. S8.10.1 ATTACHED & FREESTANDING SLID COVERS - 10 PSF SNOW LOAD OR LIVE LOAD -110 MPH M EXP. B & C 6.5" ROLLFORM 62 MAG BEAM 63 4" I -BEAM 64 4.5" MAG GUTTER 85 12 GA STL'UCHANNEL 87 ABEAM a ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING TRIB WIND MAX POST FTG MIN POST MAX POST FTG MIN POST MAX POST FTG MIN POST MAX POST FTG MIN POST MAX POST FTG MIN POST MAX POST FTG MIN POST MAX POST FTG MIN POST MAX POST FTG MIN (POST MAX POST FTG MIN POST MAX POST FTG MIN POST MAX POST FTG MIN POST MAX POST FTG MIN POST WIDTH EXP SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING ON) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING ON) TYPE SPACING (IN) TYPE SPACING ON) TYPE SPACING (IN) TYPE (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) 5' 110 B 11'-9" 1 B C1 l V-9 26 C7 1014, 17 Cl 9'$" 25 C7 13W" 19 Cl 12'-4" 27 13'-3" 19 12'-7 27 13' 4" 19 12'-10" 27 23'-4" 22 21'-3" 31 110 C 11 9 20_ 11'-4" 2B 10'-0" i9 9'-2" 26 13'-T' 21 12'A" 28 C7 13'-3" 21 Cl 11'-91 28 C7 12'-3" 5 C7 11'-10" 20 C7 23'-4" 25 C5 20'-g" 33 C7 6 110 B la-g. 18 C1 10'-9" 26 C7 9'-9" 18 Cl 8'-10" 24 C7 12'-V' 19 C7 11'-8" 28 12'-7' 19 11'-6" 26 12'7" 19 11'-6' 26 22=0" 23 - 2D'-0" 30 110 C 10-9" 21 9'-9" 20 8'�" 26 12'-9" 22 11'�" 2B 17-7' 21 11'-7' 28 10'�" 27 C7 Cl C7 11'-3" 21 Cl 11'-0' 2B C7 22'-0" 26 C5 19'3" 32 C7 7 110B 17-0" 19 Cl 1U-T 26 C7 9'-3" 18 Cl 8'-0" 25 C7 12'-2" 20 C1 lV-l" 26 11'-3" 20 10'-1D" 26 12'-0" 20 11'-0" 26 2D'-10" 24 19'-0" 30 110C 10'-0" 21 9'-8" 27 9'-3" 21 B'-3" 26 12�_2' 23 10_9,. 27 C7 11�_3' 2 Cl 10,T, 27 C7 1V-4" 21 C1 1D,_2" 27 C7 20'-10" 27 C5 18'T' 32 C7 8' 110 B 9' 4' 19 C1 9'-4" 26 C7 8'-10" 19 Cl 8'-2" 25 C7 1 V4, 21 C2 10'-7" 27 10'-T' 20 1014, 27 11'-0" 21 10'-0" 27 2V-1" 25 18'-2" 31 110C 9'-4" 22 9'-1" 26 8'-1D 21 7'-fU, 25 1V-8" 23 10'-0" 27 C7 10'-7' 23 C1 10'-7' 27 C7 9'-9" 22 C2 9'-7" 27 C7 20'-1"' 28 C5 17'-9" 31 C7 9 110 B 8'-10" 20 Cl W-70" 27 C7 8'-T' 19 Cl T-9" 26 C7 11'-1" 21 C2 10'-2" 28 10'-0" 20 10'-0" 27 1 V-D" 21 10'-1" 28 19'-2" 25 17'-0" 32 110 C 6'-10" 22 8'-T' 26 8 7 22 7'-T' 26 11'_1„ 24 10'-0" 27 1p'-0 23 9'-7' 27 C7 C1 C7 9'-2 22 C2 9'-0" 27 C7 19'_2- 28 C5 17,_1„ 32 C7 10' 11D B B' 6 20 Cl B' 6 27 C7 8'-3" 20 C1 7'-T 26 C7 10'-8 22 C2 9A0" 28 5-0" 21 9'-0" 28 10'�" 21 9-9 2B 18'-3" 26 16'-10" 32 110 C 6'-0 23 8'-1" 27 87 22 7'4" 27 1U-6' 24 V-7" 2g 9'-0 29 C7 C2 9-2 28 C7 8'-9 23 C2 6'-T' 27 C7 18'-3" 29 C5 1B' S' 32 CB 11' 110 BW 21 C2 B'-1" 27 C7 8'-0" 20 C1 7'-4" 27 C7 10'-0" 22 C2 9'-T' 29 C7 110 C23 T-9" 28 8'-0" 23 7'-7' 2B 10'-0' 25 C2 C7 C2 C7 C5 CB 12' 110 B7-4' 21 C2 7'-6" 28 C7 7'-T' 21 C2 C7 C5 110 C24 T-0" 2B 7'-7 23 7'-0" 28 9 7" 25 9' 1" 29 C7 B'-g" 24 C2 8'�" 2B C7 g'-0" 23 C2 T 10" 28 C7 16'$" C5 15' 7 33 CB AM B7 (1)IC'"EIN INSERT AM B8 (2)'C"EINSERT 68 DBL2x6.5x0.042 81D DBL2x6.5x0.032 3x8x0.042 S 812 DBL3x8x0.042 ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN TRIB WIND POST FTG POST POST FTG POST POST FTG POST POST FTG POST POST FTG POST POST FTG POST POST FTG POST POST FTG POST POST FTG PbST POST FTG (POST POST FTG POST POST FTG POST WIDTH EXP SPACING ON) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING ON) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING QN) TYPE SPACING (IN) TYPE (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (BRAN) (SPAN) (SPAN) (SPAN) 5 11 D B 26 -9 23 C5 "" 32 C7 29'-6" 24 C5 26'-1 D" 33 CU14 20 Ct 1"" 29 1 T-2" 19 13'-7' 27 13'-0" 19 13'-8" 27 19'-3" 21 19'-3" 30 115C ZBA 26 23'-0" 34 C8 29'6" 27 26'-7' 35 C22 15' 3" 30 C7 12'-7' 21 Cl 12'-3" 25 C7 12'-10" 21 G1 12'-7' 29 C7 18'-1" 23 C2 17'3" 31 C7 6 110 B 25-3 24 C5 23'-0" 31 C7 27'-9" 25 C5 25'-3" 32 C 20 14'-7" 28 12-1" 19 12'-1" 27 12' 6 19 12'�' 27 17 7 22 17'-T' 29 110 C 25'-3" 27 22'-0" 33 CB 27'-9" 28 24'-T' 34 C23 C1 14'-0" 29 C7 11'•5' 21 C1 11'-2' 28 C7 11'-9" 21 Cl 11'-6" 2g C7 16'-0 24 C2 1g,_1„ 31 C7 7 24'-T 25 CS 21'-9" 32 C7 26'�" 26 C523'�" 24'-0' 3221 C23 C2 13'-0" 2B 11'-2" 2D 11'-7' 27 11'-7" 20 11'-T' 27 16-3" 22 16'-3" 29 24'-0" 28 21'_3" 33 C8 26'4" 29 34 13'-0" 29 1D S„ 2? 10'4" 27 C7 C1 C7 10'_1D" 22 C1 1D'_g" 27 C7 15'_3" 24 C2 15'-0" 3DC7 8 23'-0" 26 C5 20'-10"32 CB 25'-3" 27 CS 23'-0" 3321 C24 C2 12'-8" 28 C7 10'-0" 2U 10'-0" 27 10'-10" 20 10'-10' 27 15'-3" 23 15'-3" 30 20._3" 32 25'_3" 30 224' 33 12'_2" 29 10,-0„ 22 9.9. 27 F10 23'-0" 29 C7 C7 1D'_2 22 C1 10'_D" 27 C7 14'-0" 25 C5 14'_9' 29 C7 22'A" 27 C5 20'-1" 33 CB 24'-3" 27 C5 22'-1" 34 C8 12'-0" 22 C2 12'-0" 29 9'-10" 21 C2 9'-10" 27 10'-2" 21 C2 1 D'-7' 27 14'-4" 23 14'�" 30 27-1" 30 C7 C7 C7 13'7" 25 C5 13' 2" 30 C7 19'7" 33 24'-3" 31 21'-7" 34 C9 12'-T 24 11'-6.. 29 9'4" 23 C1 9'-7' 27 9' 8" 23 C1 9'�" 27 10' 21' 4" 27 C5 19'�" 34 CB 23' 6" 28 C5 21'-4" 35 C9 11'<1" 22 C2 11'-0" 29 9' 4" 21 9' 4" 2B 9'-2" 21 9'-2" 2B 13'-B" 24 13'-B" 31 110 C 21'-4" 31 1 B'-1 D'" 33 23'-0" 32 2T-9" 34 11'_" 25 1 D'-10" 29 C7 9'-D" 23 C2 8'-9" 27 C7 9'-2" 23 C2 B'-0" 27 C7 12'-1 D 26 C5 12'-7" 30 C7 11' 110B 20'-6" 2B C5 18'-9" 34 C9 27-9" 29 C5 294' 35 C9 10'-10" 22 C5 1D'-10" 30 9'-0" 21 9'-0" 28 8'11" 21 B'4" 2B 13'-1" 24 13'-1" 31 18'-3" 34 22'-9" 32 2D-2" 35 10'-10" 25 10'�" 29 8'7" 23 116 C 20'-0" 31 C7 C2 C7 C2 C7 C5 C7 12' 11D B 2D'-1" 28 C5 18'-3" 35 C9 27-1" 29 C5 2D 1" 36 C10 10'-0" 23 C5 1D'�" 30 8'-7" 21 110 C 20'-1" 32 C7 C2 C7 C2 C7 C5 11' 6 31 C7 1T -- 35 22'-1" 33 19-T' 35 10'4 26 8'-2" 23 8'-0" 28 7' e 23 T-1" 2B 11'-9" 27 3 V/ B13 14 GA STL INSERT814 B15 DBLB14 GA STL INSERT 816 DB B12 GA STL INSERT618 12 GA STL U-IN E,RT 619 1D2 GA STL U-INS RT 12 GA STL INSERT ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING ATTACHED I FREESTANDING ATTACHED FREESTANDING ATTACHED FREESTANDING TRIB WIND MAX POST FTG MIN POST MAX POST FTG MIN POST MAX POST FTG MIN POST MAX POST FTG MIN POST MAX POST FTG MIN POST MAX POST FTG MIN POST MAX POST FTG MIN POST MAX POST FTG MIN POST MAX POST FTG MIN POST MAX POST FTG MIN POST MAX POST FTG MIN POST MAX POST FTG MIN POST WIDTH EXP SPACING ON) TYPE SPACING 0N) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING OM TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING (IN) TYPE SPACING ON) TYPE (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) (SPAN) 5 110 B 18' 4" 21 C2 18'-0" 30 C7 20'-1" 21 C2 2U-1" 3D C7 25'-10" 23 C5 25'-10" 32 CB 2>� 4 24 27'-0" 35 25'-10' 23 C8 25'-1 T 46 32'-T 25 C6 32'-0" 49 710 C iB'�" 23 1T8 31 CS 27,-0 37 C10 C10 C10 20-1' 24 19'-0" 32 25, IT 28 24-10" 3d 2B 4" 27 ZZ-11' 25 C6 22'-11' 44 2B'-11" 27 C6 28'-11" 47 t? 110 B i 8'S" 21 C2 16'-9" 29 C7 1 B'-4" 22 C2 18'-4" 30 C7 23'3" 24 C5 23'-B" 32 25-1 D" 25 25'-10" 34 24'-3" 24 C6 24'-3' 48 30'-T 26 C6 30'-T 51 11D C 18'•9 24 CB C5 24'_1p" 36 C10 C10 C10 16'-7' 31 16," 25 1T-B" 31 23'-0" 27 27-9" 33 25'_1p" 27 21'7" 26 C5 21'-7" 46 27'-2" 29 C6 2T-2° 48 T 110 B 15-7 22 C2 7517' 29 C7 1T-1" 22 C5 17'-1" 30 C7 22'-0" 24 C5 22'-0" 32 24'-0" 25 24'-0" 34 23'-1" 25 C6 23'-1' 49 29'-1' 27 C6 29'-1" 53 11D C i5T' 24 CB C5 2T-1" 35 C10 C10 CID 15.0" 30 17-1" 25 16'-0" 31 22'-0" 27 21'-l" 33 24'-0" 28 20'-6" 27 C6 20'-0' 47 25'-10" 29 C6 26-10" 51 8 110 B 14'-7" 22 C5 14'-T' 29 C7 16'-0" 23 C5 16'-T 30 C7 20'-7' 25 C5 20'-7" 32 CB 22'-0" 26 22'-0" 34 22'-V 25 C6 22'-1' S1 27'-10" 27 C6 2T-10" 54 110 C 14'7" 25 14'-1" 29 16-0" 26 15'4" 30 20'-T' 2B 19'-9" 32 2Z- 29 C5 21 T, 34 C70 19'7" 28 C6 1V-7' 49 C10 24'-B"B"" 30 06 24'- 52 C10 9, 110 B 13'-9" 23 C5 13-9" 30 C7 15'-1" 23 C5 15'-1" 31 C7 1914, 25 C5 19'4' 33 21'-2' 26 21'-7' 35 21'-2" 26 C6 21'-2' 52 26'-9" 28 C6 25-9" 56 CB C5 20'4' 35 C10 C10 C1D 110 C 13'-0 26 13.3 30 15-1" 26 14'-6' 30 19'14" 29 18'-7" 32 21,_7, 29 18'-10' 29 C6 18'-10' 50 23'-9" 31 C6 2V-9" 54 10' 110 B 13'-1" 23 C5 73-1" 3D C7 14'-3" 24 C5 14'-3" 31 C7 18'4" 26 C5 18'�" 33 C8 2U-1" 27 20'-l" 35 2D-6' 27 C6 2D'-0" 53 25-10' 29 C6 25'-1D" 57 110 C 13'-1" 26 12=T' 30 C5 19,�„ 35 C10 CID C10 14'-3" 27 13'•9" 31 1814, 29 iT-8" 33 20'-l" 30 18'-2" 30 C6 18'-2' S1 22'-11" 32 C6 22'-11" 55 11' 110 B 12'-0" 24 C5 12'3" 31 C7 1 T-8" 24 C5 13'3" 31 C7 17'-7' 26 C5 17'-7" 34 19'-T 27 19'-7' 36 19'-1 p' 27 C6 19'-10' 54 25'-0' 29 C6 26-0" 58 110C i2'-8" 26 C8 C5 18'6 35 C10 C10 C10 12'-0' 30 1&-v 27 13'-1" 31 17'-7' 3p 16'-1D" 33 19'-7' 30 17'-7° 30 C7 1T-7' S2 �_2' C7 22'-2" 56 12' 110 B 12'-0 24 C5 12'4' 31 C7 13'-1" 25 C5 13'-1" 32 C7 16,4, 27 CS 16'-9" 34 18'�" 20 18' 4" 36 19'-3" 28 C6 IY3' 55 24'-3' 0 J333 C6 24'-3" 59 11D C IT -a' 27 176-- 31 C9 C5 010 C10 C10 13'-1" 28 12'-7" 32 16'-9" 30 16'-2" 34 18'�" 31 17'-B" 36 17'-1" 31 C7 1T-1- 53 2V-7' C7 21 y7 NOTES: 1 - WHEN THE PAT10 COVER IS INSTALLED ON A SLAB ON GRADE (RESIDEMIAL APPLICATIONS ONLY), THE MAXIMUM POST SPACING IS THE LOWEST OF THE "MAX POST SPACING (SPAN)" SHOWN ABOVE AND THE MAXIMUM POST SPACINGS SHOWN ON DETAIL 8IS7.1 2 - IT IS ACCEPTABLE TO SUBTITUTE COLUMNS W/ HIGHER NUMBERS W1 THOSE SPECIFIED IN THE TABLES SHOWN. 2485 RAILROAD ST, CORONA, CA 92880 951.736.4500 1 C 4gpFEss 16. S585 9TF OF CA`'��` DATE SIGNED: July 8, 2019 V: W�z � � � � 26030 ACERO, SUITE 200 MISSION.VIEJO, CA 92691 949.305.11501 FAX 949.305.1420 SAP mo ES TM EXPIRES ON: JUNE 30, 2020 REVISIONS MARK DATE DESCRIPTION 4 STEL JOB # DA02-02 DATE 071OB119 DRAWN BY RC CHECKED MDS IAPM0195 V 3.1.1 SOLID COVER STRUCTURES: BEAM SPANS & FOUNDATION SIZES 10 PSF LUSL, 110 MPH S8. 10.1 TABLE 3 - (MAX WIND SPEED: 130MPH, EXP C) MAXIMUM POST SPACING WHEN PATIO COVER IS INSTALLED ON SLAB ON GRADE ROLLED FORMED PANS (RF) IRP LL/GSL(psf) GSL(psf) LL/GSL(psf)10 psf 20 psf 25 psf 30 psf 10 psf 20 psf kTRI 13'-7" 11'-0" 10'-4" 9'-0" 12'-6" 10'-0" 11'-4" 9'-9' 9'-0" 8'-4' 10'-5' 8' 9" 91-81, 9.0.E 8'-0" 7%6" 9'-0' 8'-W 8' 8'-6' 8'-6' T-6^ 7'-0" T-10" 7%6" 9' 7'•7" 8'-0" 7'-0" NP T-0` 7`1" 10, 6'-9" 7'.6" NP NP 6'-3" 6'-6" 11' 6'4" 7'•0' NP NP 51•8" 6'-0" 12' 1'-9" 6' -6" NP NP 5'-3" 5'-6" NOTES: 1- "NP" I NDI CATES THAT A FOOTING IS REQUIRED, AND THE PATIO COVER CANNOT BE SUPPORTED ON ASLAB ON GRADE. 2 -FOR LIVE O R SNO W LOADS HIGHER THAN TH E O NES SHOWN ON THIS TABLE, A FOOTING IS REQUIRED AND THE PATIO COVER CANNOT BE INSTALLED ON SLAB ON GRADE. TABLE 4 - (MAX WI ND SPEED:130MPH, EXP C) MAXIMUM TWO POST ATTACHED STRUCTU RE W I DTH WHEN PAT10 COVER IS INSTALLED ON SLAB ON GRADE TRIB WIDTH H ROLLED FORMED PANS (RF) IRP LL GSL(psf) LL/GSL(psf) (ft) SO psf 20 psf 25 psf 1 30 psf 10 psf 20 psf 5 27'-2" 22'-0" 20'-B" 18'-0" 25'-0" 20'-0" 6 22'•8` 19'-6" 18'-0" 16'-8' 21'-0" 1T-6" 7 19'-4" 18'4" 16'-0" 15'-0" 18'-0" 16'-0" 8 17'-0" 17'-0" 15'-0" 14%0" 15'-8" 151•0" 9 15'-2" 16'-0' 14'-0" NP 14'-0" 14'-0" 1D 13'.6- 15'-0" NP NP 12'f" 13'-0" 11 12'A" 14'-0" 1 NP NP 11'-4" 12'-0" 12 11'-4" 13'-0" NP NP 10'-6" 11'-0" 9 T BRACKET CONNECTION TO SLAB ON GRADE 1"=1'-0" O OO ::t I.ASTM A500 GRADE B `P - N Oo Oo NSERT TO PLAN 3 6" BASE PL 3" STEEL POST =_ �THICK MIN HSS Q HSS INSERT �^I ��(3) 3'4"0 BOLTS 1 r10" SO.x 5" BASE PL T.O.C. NOTES: ELEVATION 1. THIS BRACKET IS TO BE USED WITH POST TYPE C7, C8 & C9, AND WITH C6 (WHEN FOOTING SIZE IS 25" OR LARGER). 2. SEE TABLE 2 ON S7.1 FOR ATTACHMENT TO FOOTING/SLAB. 3. INSTALL 1Y4 x IN x K HDG WELDED WASHER PLATE WHEN HOLE DIAMETER IS MORE THAN Ya" BIGGER THAN ANCHOR BOLT DIAMETER. 4. THIS BRACKET CAN ALSO BE USED FOR POST TYPE C2, C5, OR C6 (ALL FOOTING SIZES) SEE TABLE 2 ON S7.1 AND 7/S7.1 FOR ANCHORAGE REQUIREMENTS. D4STEELFPOST SLEEVE OR POSTS C% CT, C8, C9 3"=V-0" 3" STEEL OR T / 'CENTERLINE OF 'P T11 / BRACKET TO BE ARALLf1 ALUMINUM POST TO HOUSE WALL ALUM ALLOY 6067rT8 2 SMS OR }----•;• OR TEK EK SCREWS, I EA. SIDE, TYP. 0 N I I W0 HOLE EA SIDE i Q.QaS T1P. i 0.750" 5.662" TYP. NOTES: 1. BRACKET LENGTH IS 2.75" 2. THIS BRACKET IS TO BE USED WITH POST TYPE Cl. WITH OR WITHOUT SIDE PLATES PER SP3 OR SP4. 3. SEE TABLE 2 ON S7.1 FOR ATTACHMENT TO FOOTING/SLAB. 4. INSTALL 14 x 1Y x K HOG WASHER PLATE AT ANCHORS FOR 130 MPH ALUMINUM T-BRACKET FOR POST Cl 3"=1'-0" ALUM ALLOY 6063 T6 4-114 SMS FII OR TEX SCREWS, SIDE, EA SIDE, TYP. I I %"0 HOLE EA. SIDE j 0.094' TYP. I 0.750" 5.50" TYP. NOTES: 1. BRACKET LENGTH IS 2.75". ADJACENT GRADE I '7' BRACKET PER 1/S7.2, 2. THIS BRACKET IS TO BE USED WITH POST TYPE C2 OR C5, WITH OR WHERE OCCURS 2/S7.2 OR 3/S7.2 WITHOUT SIDE PLATES PER SP3 OR SP4. 3. SEE TABLE 2 ON S7.1 FOR ATTACHMENT TO FOOTING/SLAB. 6' M1N. SEE NOTE 6 EXISTING OR NEW SLAB ON F-GRADE. fc=2,500 PSI MIN. 4• INSTALL 1J�x 1J¢xJ6 HD�WASHER PLATE AT ANCHORS FOR 130 MPH. 5. STEEL T-BRACKET PER 3 S7.2 CAN BE USED IN UEU OF THIS BRACKET. i � d 7211;_�'1101` SEE NOTE 6 SLAB BOLTS PER TABLE 2 ON 4/S7.1 WHERE OCCURS NOTES: 1. THIS DETAIL CAN BE USED WITH POST TYPES Cl, C2, C5, OR C6. 2. TABLES 3 AND 4 IN THIS DETAIL CAN BE USED FOR FREESTANDING STRUCTURES AND/OR COMMERCIAL APPLICATIONS, BUT THE STRUCTURE CANNOT BE INSTALLED ON A SLAB ON GRADE AND REQUIRES A FOOTING PER SB.xx.x. 3. THIS DETAIL SHALL NOT BE USED FOR POST TYPE C10 & Cl I. 4. SEE "SLAB ON GRADE USED AS A FOUNDATION SYSTEM" NOTES ON GO.1 FOR MINIMUM OVERALL DIMENSION OF SLAB AND ACCEPTABLE CRACKING AND CONTROL/EXPANSION JOINTS CRITERIA 5. WHEN THE PATIO COVER IS INSTALLED ON A SLAB ON GRADE (RESIDENTIAL APPUCATIONS ONLY), THE MAXIMUM POST SPACING IS THE LOWEST OF THE "MAX POST SPACING (SPAN)" SHOWN ON S8.XX.1 AND THE MAXIMUM POST SPACING SHOWN IN TABLE 3. 6. SEE NOTE 2 ON 4/57.1 FOR ALTERNATE 7. THIS DETAIL CAN ONLY BE USED IN AREAS WITH A FROST DEPTH EQUAL TO ZERO. 8. SEE "GENERAL NOTES - SLAB ON GRADE USED AS A FOUNDATION SYSTEM' NOTES ON GO.1 FOR MORE INFORMATION. ALUMINUM T-BRACKET FOR POSTS C2, C5 4.00" ASTM A500 GRADE B 0.75" TYP 4-W6"O HOLESyy 1.75° O 1-7WO & 2-W O N HOLES, TYP EA SIDE 6 0 _ _ It "' O O O O CENTERLINE OF T" BRACKET TO PLAN 2 OO't PARALLEL TO - 3.50" 11.00'. HBE OUSE TYP n 2-3(6"0 HOLES FOR X''0 M.B. TYP. cV c ELEVATION --- NOTES: 1. THIS BRACKET IS TO BE USED WITH POST TYPE C6 WHEN FOOTING SIZE IS 29 OR SMALLER, WITH OR WITHOUT SIDE PLATES PER SP3 OR SP4. 2. BRACKET CAN ALSO BE USED WITH POST TYPE C2 OR C5 PER TABLE 2 ON S7.1 AND 2/S7.1 3. SEE TABLE 2 ON S7.1 FOR ATTACHMENT TO FOOTING/SLAB. (�) STEEL T-BRACKET FOR POST CB 3"=1'-0"