BRES2019-012178-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Permit Type/Subtype:
Application Number:
Property Address:
APN:
Application Description:
Property Zoning:
Application Valuation:
T-d4r41wQ91,rw
DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT
BUILDING RESIDENTIAL/DWELLING - SINGLE FAMILY DETACHED
BRES2019-0121
53497 VIA PISA
777190004
ROVNER / 6,676SF DWELLING/VB/RES-3/CLASS A-FR/13D
$592,725.30
Applicant:
STRACTS INC - ANTON MARINKOVICH
550 S. OLEANDER ROAD
PALM SPRINGS, CA 92264
PQ °D
OCT 0 Z 2019
CITY OF LA QUINTA
DESIGN & DEVELOPMENT DEPARTMENT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9
{commencing with Section 70001 of Division 3 of the Business and Professions Code, and
my License is in full force and effect.
License Class: B License No.: 1026884
Date: I�` ` Cantrartor:
OWNER -BUILDER DECIARATION
I hereby affirm under penalty of perjury that I am exempt From Tre Eontrdctor's State
License Law for the following reason (Sec, 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any
structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the
alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that he
or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to
construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State
License Law does not apply to an owner of property who builds or improves thereon,
and who contracts for the projects with a contractor(s) licensed pursuant to the
Contractors' State License Law.).
() I am exempt under Sec. B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's
Lender's Address:
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 10/2/2019
Owner:
ROBERT & IRENE S. ROVNER
53497 VIA PISA
LA QUINTA, CA 92253
Contractor:
MARIO A YANEZ CONSTRUCTION
PO BOX 580925
NORTH PALM SPRINGS, CA 92258
(760)285-1532
LIc. No.: 1026884
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensate , as provided for by Section 3700 of the Labor Code, for the performance
of the ich this permit is issued.
ave and will maintain workers' compensation insurance, as required by
Section 700 of the Labor Code, for the performance of the work for which this permit is
issued. My workers' compensation insurance carrier and policy number are:
Carrier: NORGUARD IN5URANCE COMPANY Policy Number:
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 ofthe Labor all forthwith
comply with those provisions.
Date: Ay "Z ^!•Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSA N COVE E IS UNLAWFUL,
AND SHALL SUBJECTAN EMPLOYER TO CRIMINAL PENA D CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit issued
as a result of this application , the owner, and the applicant, each agrees to, and shall
defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance ofthis permit.
2. Any permit issued as a result of this application becomes null and void if work is not
commenced within 180 days from date of issuance of such permit, or cessation of work
for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon th e-
mentioned property for inspection purposes. f
Date: ofVrZ:�/ nature(ApplicantorAgent
Date: 10 /2019
Application Number:
BRES2019-0121
Owner:
Property Address:
53497 VIA PISA
ROBERT & IRENE S. ROVNER
APN:
777190004
53497 VIA PISA
Application Description:
ROVNER / 6,676SF DWELLING/VB/RES-3/CLASS A-FR/13D
LA QUINTA, CA 92253
Property Zoning:
Application Valuation:
$592,725.30
Applicant:
Contractor:
STRACTS INC - ANTON MARINKOVICH
MARIO A YANEZ CONSTRUCTION
550 S. OLEANDER ROAD
PO BOX 580925
PALM SPRINGS, CA 92264
NORTH PALM SPRINGS, CA 92258
(760)285-1S32
Llc. No.: 1026884
'+-------------•-------------------------
---------------------------------------
--4^-1�------
Detail: ROVNER / 6,676SF SINGLE FAMILY DWELLING - (VB/RES-3/CLASS ftff/13A�,TI IS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR
DRIVEWAY APPROACH. 2016 CALIFORNIA BUILDING CODES. U
r��M?��w.�C ..',iliIGi;�yti'rtlf 3Nc)I�=,
t
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT QTY AMOUNT
ART IN PUBLIC PLACES - RESIDENTIAL
270-0000-43201 0 $981.81
Total Paid for ART IN PUBLIC PLACES - AIPP: $981.81
DESCRIPTION
ACCOUNT
CITY AMOUNT
BSAS SB1473 FEE
101-0000-20306
0 $24.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $24.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - CIVIC CENTER
252-0000-43200
0
$942.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - COMMUNITY CENTERS
254-0000-43200
0
$129.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - FIRE PROTECTION
257-0000-43200
0
$433.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - LIBRARIES
253-0000-43200
0
$344.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - PARK MAINTENANCE
256-0000-43200
0
$40.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - PARKS/REC
251-0000-43200
0
$2,048.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DIF - STREET MAINTENANCE
255-0000-43200
0
$116.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DIF - TRANSPORTATION
250-0000-43200
0
$2,842.00
Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
TEMP POWER SERVICE
101-0000-42403
0
$26.68
DESCRIPTION
ACCOUNT
QTY
AMOUNT
TEMP POWER SERVICE PC
101-0000-42600
0
$18.68
Total Paid for ELECTRICAL: $45.36
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL, EA ADDITION 1,000SF
101-0000-42403
0
$95.27
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL, EA ADDITION 1,000SF, PC
101-0000-42600
0
$39.20
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL, FIRST 1,000SF
101-0000-42403
0
$160.10
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RESIDENTIAL, FIRST 1,000SF, PC
101-0000-42600
0
$52.83
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $347.40
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FIRE NEW RESIDENITIAL PC
101-0000-42420
0
$240.00
Total Paid for FIRE FEES: $240.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT>7KSF
101-0000-42408
0
$40.02
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT>7KSF PC
101-0000-42600
0
$200.12
Total Paid for GRADING: $240.14
DESCRIPTION
ACCOUNT
QTY
AMOUNT
CONDENSER/COMPRESSOR
101-0000-42402
0
$240.12
DESCRIPTION
ACCOUNT
QTY
AMOUNT
CONDENSER/COMPRESSOR PC
101-0000-42600
0
$160.08
DESCRIPTION
ACCOUNT
QTY
AMOUNT
EXHAUST HOOD
101-0000-42402
0
$13.34
DESCRIPTION
ACCOUNT
QTY
AMOUNT
EXHAUST HOOD PC
101-0000-42600
0
$5.34
DESCRIPTION
ACCOUNT
QTY
AMOUNT
FURNACE
101-0000-42402
0
$240.12
DESCRIPTION
ACCOUNT
QTY
AMOUNT
FURNACE PC
101-0000-42600
0
$160.08
DESCRIPTION
ACCOUNT
QTY
AMOUNT
VENT FAN
101-0000-42402
0
$120.06
DESCRIPTION
ACCOUNT
QTY
AMOUNT
VENT FAN PC
101-0000-42600
0
$48.06
Total Paid for MECHANICAL: $987.20
DESCRIPTION
ACCOUNT
QTY
AMOUNT
NEW CONSTRUCTION PERMIT
101-0000-42400
0
$885.65
Total Paid for NEW CONSTRUCTION PERMIT: $885.65
DESCRIPTION
ACCOUNT
QTY
AMOUNT
NEW CONSTRUCTION PLAN CHECK
101-0000-42600
0
$1,918.89
Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,918.89
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PLAN CHECK DEPOSIT- RESIDENTIAL
101-0000-42600
1
$1,200.00
Total Paid for PLAN CHECK DEPOSIT - RESIDENTIAL: $1,200.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
BACKFLOW DEVICE
101-0000-42401
0
$13.34
DESCRIPTION
ACCOUNT
QTY
AMOUNT
BACKFLOW DEVICE PC
101-0000-42600
0
$5.34
DESCRIPTION
ACCOUNT
QTY
AMOUNT
BUILDING SEWER
101-0000-42401
0
$26.68
DESCRIPTION
ACCOUNT
QTY
AMOUNT
BUILDING SEWER PC
101-0000-42600
0
$18.68
DESCRIPTION
ACCOUNT
QTY
AMOUNT
FIXTURE/TRAP
101-0000-42401
0
$493.58
DESCRIPTION ACCOUNT QTY AMOUNT
FIXTURE/TRAP PC
101-0000-42600
0
$493.58
DESCRIPTION
ACCOUNT
CITY
AMOUNT
GAS SYSTEM, 5+ OUTLETS
101-0000-42401
0
$40.02
DESCRIPTION
ACCOUNT
CITY
AMOUNT
GAS SYSTEM, 5+ OUTLETS PC
101-0000-42600
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
ROOF DRAIN
101-0000-42401
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
ROOF DRAIN PC
101-0000-42600
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WATER HEATER/VENT
101-0000-42401
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WATER HEATER/VENT PC
101-0000-42600
0
$16.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WATER SYSTEM INST/ALT/REP
101-0000-42401
0
$13.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WATER SYSTEM INST/ALT/REP PC
101-0000-42600 j
0
$13.34
Total Paid for PLUMBING FEES: $1,240.62
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($21.00)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RECORDS MANAGEMENT FEE - MAJOR
101-0000-42416
0
$21.00
Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $0.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SMI - RESIDENTIAL
101-0000-20308
0
$77.05
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $77.05
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($5.00)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $0.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($1,174.00)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SINGLE FAMILY DETACHED 2018 UPDATE
224-0000-20320
0
$1,174.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SINGLE FAMILY DETACHED 2018 UPDATE
224-0000-20320
0
$1,136.00
Total Paid for TUMF - RESIDENTIAL: $1,136.00
TOTALS:
PERMIT
PLXNI J,OCATION:
Project Address: u�1+ /S.
Project Description: Pool, Remodel, Add't, Elect, Plumb, iMech
Applicant Name;$
Address:
SSU D
City, ST, Zip:
Telephone:
76oU. g
Email:
AAl�rh S __ L. C!/I�
Valuation of Projects !d(', "'Jac, 00
Contractor Name: � New SFD Construction:
Address: r �� Conditioned Space
City, St, Zip Garage
Telephone: Patio/Porch
Email: Fire Sprinklers
State Lic: City Bus Lic:
416? ZSF
/!p LO SF
SF
&1e7�2 SF
Arch/En Name: 5z$ 7-/y c ` P -
gEe 4ALY fi[Gf�
Construction Ty e• Occu anc�:
p //YO,v gt1T� p /tS U/
Address: G
Grading:
City, St, Zip 5 4-6
Telephone: 7C20 :
Bedrooms: Stories: ✓� , # Units:
Email:
State Lic: G_.3y y City Bus Lie:G/�5/efGr�
Property Owner's Name:,A
Address: :?y±z
City. ST, Zip Pli,1f k lu
Telephone: ! • C�+•
Email:
ecl
/ Tenant Improvements:
Total Building SF
Construction Type: Occupancy:
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
Water Quality, Manaciement Plan (WQMP) Exemotion Form - Whitewater River Renion
Documentation of Project Not Reg Wring a WQMP but Re y ring Site Design BMPs and Source Control
by Entitlement Conditions of Approval or Permit Conditions — WQMP Required for the Listed Change of
BMPs
Land
Uses or for Changes of Pollutant Stream (All Questions Below Must be Answered "No" To Exempt Project)
Yes
No
Entitlement or construction of new single-family hillside residence(s) that create 10,000 square feet, or
of impervious area where thUre-development natural slope is 25% or greater?
Elmore,
21
Entitlement or construction of new single-family hillside residence(s) that create 10,000 square feet, or
more, of impervious area where the pre -development natural slope is 10% or greater where erosive
❑
_soil conditions are known?
Entitlement or construction of new commercial and industrial development(s) of 100,000 square feet
or more?
Entitlement or construction of new automotive repair shop(s) including body, upholstery, paint,
exhaust, tire, transmission, engine or other automotive specialty repair. [Standard Industrial
Classification (SIC) codes 5013, 7532, 7533, 7534, 7537, 7538, and 753�?
Entitlement or construction of new retail gasoline outlet(s) disturbing greater than 5,000 square feet?
Entitlement or construction of new restaurant(s) (or potential restaurant shell space) disturbing greater
than 5,000 square feet?
❑
Entitlement or construction of new home subdivision(s) with 10 or more housing units?
Entitlement or construction of new parking lot(s) of 5,000 square feet or more, or with 25 or more
parking spaces, and potentiallyex aced to Urban Runoff?
❑
Applicant
Information
Name and Title
Mike Tuvell, President
Company
Sunrose Corporation
760-218-0566
sunrose.sedona@gmail.com
T T Phone
Email
Project Information
Project Name
Rovner Residence
Type (SFH, Multi -Family, Commercial, Etc.)
SFR
Location or Street Address
53-497 Via Pisa
Nearest Cross Streets
Via Pessaro
Municipality/County/Zip Code
La Quinta
Tract Number(s) and/or Assessor Parcel Number(s)
29894-2 / 777-190-004
Other Location Information
Watershed
Whitewater River
Source Control BMP Information
Size of Project Area (nearest 0.1 acre)
15953
Project Area managed with Site Design or Low
Impact Development (LID) 13MPs (nearest 0.1 acre)
Is the project subject to onsite retention by City
ordinance or policy?
yes
Sunrose Corporation
Name of the Entity that will implement, operate, and
maintain the Source Control BMPs
Contact Name
Cole Tuvell
Street or Mailing Address
40101 Monterey Ave. 131-214
Rancho Mirage
City
Zip Code
92270 - -�
760-218-0566
Phone
TAChecklists - Forms 8 Applications\Forms 8 Applications\GREEN SHEET cover 8 PM10less than 1 Acre Revised 9-25-09.doc
Check Item I To be Source Control BMP Requirements - All Projects Require Non -Structural BMP Source Control
Performed Non -Structural BMP (See Appendix H, Section 4.5.2.1)
Ongoing Irrigation System and Landscape Maintenance
Ongoing Litter Control `—
�/ Ongoing Drainage System Inspection & Maintenance
Education/Training for Property Owner, Operators, Occupants, or Employees
✓�
Activity Restrictions — Prohibition of Debris Blowing/Sweeping/Washing into Street/Storm Drain, Closed
Trash Lids, Restriction of Vehicle Washing
Ongoing Street Sweeping at Private Streets and Private Parking Lots
Check Item
Source Control BMP Requirements — Small Sloped Lots, Small Commercial, <10 Unit
To be
Subdivisions, <5,000 Square Ft. Parking Lots, Etc.
Provided
Structural BMP (See Appendix H, Section 4.5.2.2)
Storm Drain Inlet Stenciling and Signage
Landscape and Irrigation System Design to Minimize Erosion & Nuisance Runoff
Protection of Slopes and Channels to Minimize Erosion
Multi -Family Project Use of Community Car Wash Racks
Wash Water Controls for Food Preparation Areas to Use Sanitary Sewer
Fueling Area (Design & Maintenance) Including PCC Surface, Canopy & Spill Prevention
Air/Water Supply Area Drainage (Design & Maintenance) Including Spill Area Containment
Trash Storage Areas (Design & Maintenance) Including Attached Lids, Storm Water Controls
❑
Loading Docks (Design & Maintenance) Including Storm Water Controls, Dry & Frequent Cleaning
Procedures
Maintenance Bays(Design& Maintenance) Including Indoor Location & Storm Water Containment
Vehicle and Equipment Wash Areas (Design & Maintenance) Including Canopy & Containment
Outdoor Material Storage Areas (Design & Maintenance) Including Canopy & Containment
Outdoor Work Areas or Processing Areas (Design & Maintenance) Including Canopy & Containment
CC&R's, Maintenance Agreements or Other mechanisms will be used to ensure the ongoing operation,
❑
maintenance, funding, transfer and implementation of the project -specific WQMP requirements. Legal
description and plat stamped by Registered Surveyor to be attached to the applicable CC&R or
Maintenance Agreement for recordation at Riverside County. (Optional Requirement to be reviewed on
a Project by Project basis)
BMP Acknowled
The applicant shall comply with listed BMPs and applicable
provisions of the City's NPDES stormwater discharge permit,
LQMC Sections 8.70.010 et seq. (Stormwater Management and
Discharge Controls), and 13.24.170 (Clean Air/Clean Water);
Riverside County Ordinance No. 457; the California Regional
Water Quality Control Board — Colorado River Basin Region
Board Order No. R7-2008-0001 and the State Water Resources
Control Board's Order No. 99-08-DWQ.
ement
Signature:
Print Name: Cole Tuvell
Title: Administration
Date: 9 119 12019
Phone: (76_ 0 218-0566
T!1Checklists - Forms & ApplicationsWorms & Applications\GREEN SHEET cover& PM10less than 1 Acre Revised 9-25r09 doc
Building Permit Number:
Project Description: �SFR
Exempt: ❑
(Materials may contain hazardous wastes and
are not subject to recycling provisions)
Construction Debris Management Plan
Plan Submittal Date
Job Site Address
Owner's Name
Number, Street, or PO Box
City, State, Postal Code
Owner's Phone Number
Owner's E-Mail Address
Project Manager's Name
Project Manager's Phone Number
Project Manager's E-mail Address)
Builder! Contractor
Number, Street or PO Box
City, State, Postal Code
Project Square Footage
City Approval By
Date of City Approval
9/19/2019
53497 Via Pisa (Lot #279)
Robert and Irene Rovner
c/o 40101 Monterey Ave #B1-214
0
9
Rancho Mirage, CA. 92270
iE
c/o (760)-702-0119
Sunrose Corp
(760) 702-0119
!!"I-00��
�-�J
cc
c�
CA-
9
sunrose."dgm(o)a all con
CL
Sunrose Corp
w
�
40101 Monerey Ave #B1-214
n1
Rancho Mirage, CA. 92270
7,696sq ft
r'
Renado Gouldlock/DEC-SuMec Wash-
Materials To Be Discarded:
Product
Tons
Trash
25.00
Not recyclable
Asphalt
0.00
Recyclable
Brick/Block
0,00
Recyclable
Cardboard
0.00
Recyclable
Commingled
0.00
Recyclable
Concrete
26.00
Recyclable
Drywall
4.00:
Recyclable
Donated / Reuse*
0.0011 Recyclable
*Describe Items
Product
Tons
Masonry (broken)
0.00
Plaster
8.50
Scrap Metal
0.00
Tile (floor)
0.75
Tile (roof)
1.00
Wood
10.00
Landscape Debris
0.00
Totals: Recycle Trash Projected Diversion:
50.3 1 1 25.0 66.78%
I understand It Is the property owner's responsibility to submit copies of weight tickets or receipts to the District
Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the
Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobslts waste is
diverted from landfilling. The remaining material will be recycled or reused. 1 will divert, for recycling or re -use, remaining
materials generated from the first day of the project through the completion of the project in accordance with this plan. This
DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or
demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still
issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the
DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through
bi-monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer
(hvT�tar T Developer /project Manager / Supedntendant Date
Construction Debris Management Plan
Summary of Requirements
As of January 1, 2017, The Green Building Standards Code (CALGreen) requires that the construction
of most new structures in the State of California comply with sections 4.408 and 5.408 of the code in
accordance with Assembly Bill 939 requiring that no more than 35% of jobsite waste be disposed of as
trash at local land fill sites and transfer stations. Exceptions may be made for certain projects under
certain conditions.
The City of La Quinta is committed to the highest level of environmental respect, to conserving our
precious natural resources and setting an example to provide for a better world for generations to
come. Recycling helps keep reusable resources out of landfills and will also reduce disposal costs.
IMPORTANT: Burrtec Waste & Recycling Services is the City's franchise
hauler. If you choose to self -haul any recyclables or trash, you must
provide copies of all weight tickets and/or receipts from the transfer
station, landfill, or recycler as the job progresses. Clean-up companies
and other haulers are not permitted to haul waste or recyclables from the
City of La Quinta. Self -haul weight tickets should be submitted to:
Renado Gouldlock, District Environmental Coordinator -
rgouldlock@burrtecdesert.com, or faxed to (760) 340-0417, or mailed to:
41575 Eclectic Street, Palm Desert, CA. 92260.
Before applyl ng for your permit...
New Requhment
A requirement that applies to every city and
county in California is the 2010 Green Building
Standards Code (CAL Green). Effective
January 1, 2017, most newly constructed
commercial and residential buildings are
required to develop a waste management plan
and divert at least 65% of the construction
materials from landfill by recycling or reusing
them. (Sections 4.408 & 5.408, CAL Green).
Complimenting the state requirement, the City
of La Quinta requires most construction,
demolition, remodel, and tenant improvement
projects to divert a minimum of 50% of jobsite
waste from landfilling. Diversion means
recycling or reusing unwanted materials rather
than disposing of them as trash.
Prior to issuance of a building permit, the
contractor or property owner must submit a
Construction & Demolition Debris Management
Plan to the City. This is accomplished through
these simple steps:
1. Call the City's District Environmental
Coordinator (through Burrtec) at (760)
674-1026. You will receive free
assistance in preparing your C&D
Debris Management Plan and will be
provided guidance toward compliance.
Most plans can be prepared within one
working day of your initial call.
2. Once the plan is prepared, you will
receive a copy to sign and date. Please
submit this to the Community
Development Department and keep a
copy for your records.
3. You may contact the District
Environmental Coordinator anytime
during your project for guidance.
Please note.
Burriec Waste & Recycling is the exclusive
franchised hauler for the City ofLa Quinta. It is
Illegal for clean-up companies and other
haulers to haul waste from your project. Se/f-
hauling is permitted under certain conditions.
The District Environmental Coordinator will
explain your options.
Recycling, salvaging, or reusing construction
material can save you money by reducing your
disposal costs. In most cases, the tipping fees
are higher at landfills and transfer stations
than at recycling facilities. Below is an example
of the potential savings:
Disposal
cost at
Recycling
Material
IandFlll
cost
Wood
$312
$210
Concrete
$103
$30
$120
Drywall
$260
Plaster
$3631
$112
Total cost:
$1,038
$472
RECYCLING SAVINGS:
jQ56>6
The rates shown above are representative of
recent costs. However, they do fluctuate
slightly due to market conditions and other
factors. Check with Burrtec's District
Environmental Coordinator prior to starting
your job for the approximate current rates.
Recycling is good for the planet
and your bottom line.
District Environmental
Coordinator, Renado Gouldlock
(760) 674-1026
Coachella Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
(760) 398-5909 — Fax (760) 398-1224
Project Name: Hideaway
Owner's Name: Robert & Irene S. Rovner
This Box For District Use Only
DEVELOPER FEES PAID
AREA:
AMOUNT
LEVEL ONE AMOUNT:
LEVEL TWO AMOUNT:
MITIGATION AMOUNT:
1. COMMAND. AMOUNT:
DATE:
RECEIPT:
CHECK It:
INITIALS
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Address: 53-497 Via Pisa, LaQuinta
Project Description: SFD
APN: 777-190-004
Tract #:
Type of Development: Residential xx
Commercial
Total Square Feet of Building Area: 6,676 s . ft.
Date: September 26, 2019
Phone No. 760-702-0119
Lot #'s:
Industrial
Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under
penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer.
Dated: September 26, 2019 Signature:
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code Gov. Code Project Agreement Existing Not Subject to Fee
17620 65995 Approval Prior to 1/1/87 Requirement
Note:
Number of Sq.Ft. 6676 Pursuant to AB 181 any room additions or enclosures of 500
sq. ft. or less are exempt from developer fees. Any mobile
Amount per Sq.Ft. $3.79 homes being relocated within the same school district's
Amount Collected $25302.04 jurisdiction are exempt from developer fees.
Building Permit Application Completed: Yes/No
By: Larry Moen, Director Facilities Dev. & Planning
Certificate issued by: Laurie Howard, Administrative Spec. _ Signature,
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90-day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90-day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
re uirements as de i I) V.:'Y
mnent code. Additional) the amount of the fees imposed is as herein set forth whether payable at this
q ��i� Di P Y y� y P Ytime or in whole a t "i"'i I (' lificatc of Occu anc . As in the latter the 90 da s starts on the date hereof. This Certificate of
Compliance is vali[I � s issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted.
SEP 2 6 2019 11/2010
CITY OF LA QUINTA
DESIGN AND DEVELOPMENT DEPARTMENT
COMMUNITY DEVELOPMENT DEPARTMENT
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
(760) 777-7012 FAX (760) 777-701 1
CERTIFICATION OF BUILDING AREA
STREET ADDRESS OF JOB: 53-497 VIA PISA
APN: 777-190-004
DESCRIPTION OF WORK: NEW SINGLE FAMILY DWELLINGS t✓
SQUARE FOOTAGE: 6,676 S.F. �.3. 7? fw»t-d= 7-5�
OWNER'S NAME: ROBERT & IRENE S. ROVNER
For questions regarding this letter, please call:
City of La Quinta Permit Center
(760) 777-7012
Coachella Valley Unified School District
83-733 Avenue 55
P O Box 847
Thermal, CA 92274
(760) 398-5909
Desert Sands Unified School District
47-950 Dune Palms Road
La Quinta, CA 92253
(760) 771-8515
CITY OI° LA QUINTA
BUILDING DIVISION
REVIEWEC 'OR
CODE
C MPLIANCE
ATE � 112011 6Y �JF
Please note: This letter verifies conditioned square footage. Please can
your School District to verify school fees, requirement for cashier's check
or money order and hours of operation.
RECORDING REQUESTED BY:
WFQ Title Company
AND WHEN RECORDED MAIL TO:
The Rovner Family Trust ufDIT dated June 6, 1988
3481 Country Club Place
Danville, CA 94506
Order No.: 7117096
Escrow No:: F32276
A.P.N.: 777-190-004.9. TRA: _ 020.160
DOC # 2017-0249329
06/21/2017 01:00 PM Fees: $18.00
Page 1 of 2
Recorded in Official Records
County of Riverside
Peter Aldana
Assessor -County Clerk -Recorder
"This document was electronically submitted
to the County of Riverside for recording"
Receipted by: LISA #580
SPACE ABOVE THIS LINE IS FOR RECORDER'S USE
THE UNDERSIGNED GRANTOR(S) ❑ECI LRE(S) GRANT DEED
DOCUMENTARY TRANSFER TAX IS $660.00
[ X ] computed on full value of property conveyed, or
[ ] computed on full value less value of liens or encumbrances remaining at time of sale.
[ ] unincorporated area [ X ] City of La Qulnta
F{}R A VALUABLE CONSIDERAT€CN, receipt of which is hereby acknowledged,
Robert T. Ravis artd Yonhee O: Ravis, Trustees of The Ravis Fam ily Living Trust, dated September 17, 2007
hereby GRANT(S) to
Robert A. Rovner and Irene G. Rovner, Trustees of The Rovner Family Trust 'U/DIT dated June 6, 1988
the following described real property in the County of Riverside, State of California
See Exhibit °A" attached hereto and made a part hereof. RECEIVED
Commonly known as: Vacant Lot 279, La Quinta, CA 92253
Dated: June 15,.2017
A notary public or other officer completing this certificate
verifies only the identity of the individual who signed the
document to which this certificate is attached, and not the
truthfulness, accuracy, or validity of that document.
STATE OF CALIFORNIA
COUNTY OF
Ong i G before me,
a notarypublic,
pars I ally appea ed L.-4- t
to t
who proved to me on the basis of satisfactory evidence to be the
person(s) whose name(s) islare subscribed to the within
instrument and acknowledged to me that helshelthey executed
the same in hislher/their authorized capacity(ies), and that by
his/her/their signature(s) on the instrument the person(s), or the
entity upon behalf of which the person(s) acted, executed the
instrument,
certify under PENALTY OF PERJURY under the laws of the
State -of California that -the fo'egaing paragraph is true and
t-orrect. .
AUG U 7 2019
CITY OF LA QUINTA
DESIGN AND DEVELOPMENT DEPARTMENT
The Ravis Family Living Trust, dated
Sept ar 17, 2007
)SS.
Sy: Robert T. Ravis, Trustee
..
_
By: yOnhee O. Ravis, Trustee
01"w Lr.e KIMSERLY M, J4RRETT
Commission s 2129590
IDNotary eLrbiie - C&INdfnle
Rlvlrelde CGU*
Aft Comm. mires Oct 9 2019
WITNESS my hand and official seal.
Signature (Seel)
(This area for official notary seal)
M TAX STATEMENTS AS DIRECTED ABOVE r�>
Building Permit Number:
Project Description: ISFR
Exempt: ❑
(Materials may contain hazardous wastes and
are not subject to recycling provisions)
Construction Debris Management Plan
Plan Submittal Date
Job Site Address
Owner's Name
Number, Street, or PO Box
City, State, Postal Code
Owners Phone Number
Owner's E-Mail Address
Project Managers Name
Project Manager's Phone Number
Project Manager's E-mail Address
Builder / Contractor
Number, Street or PO Boxy
City, State, Postal Code
5/30/2019
53497 Via Pisa (Lot #279)
Rovner Residence
53497 Via Pisa (Lot #279)
La Quinta, CA. 92253
c/o 760-864-9448
Julie McCormick
760-864-9448
a dm i nQm iraa edeve lojer. co m
Mirage Developers Inc
72049 Petland Place suite A-2nd floor
Thousand Palms, CA. 92276
Project Square Footage I Approx. 7,696sf
City Approval By Renado Gouldlock-DEC/Burrtec Waste
Date of City Approval ��.{� !,-;,)
Materials To Be Discarded:
Product
Tons
Trash
31.50
Not recyclable
Asphalt
_ 0.00
Recyclable
Brick/Block
0.00
Recyclable
Cardboard
0.00
Recyclable
Commingled
0.00
Recyclable
Concrete
36.00
Recyclable
Drywall
4.00
Recyclable
Donated / Reuse"
0.00
Recyclable
"Describe Items
Totals: Recycle Trash
62.0 1 31.5
Product
Tons
Masonry (broken)
0 00
Plaster
_
9.00
Scrap Metal
0.00
Tile (floor)
0.75
Tile (roof)
_ 1.00
Wood 1 11.25
Projected Diversion:
Cm
I understand it is the property owner's responsibility to submit copies of weight tickets or receipts to the District
Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the
Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste is
diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining
materials generated from the first day of the project through the completion of the project in accordance with this plan. This
DMP Is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or
demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still
issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the
DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through
bi-monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer
Owner / Developer / Project Manager / Superintendant
Date
()A
Construction Debris Management Plan
Summary of Requirements
As of January 1, 2017, The Green Building Standards Code (CALGreen) requires that the construction
of most new structures in the State of California comply with sections 4.408 and 5.408 of the code in
accordance with Assembly Bill 939 requiring that no more than 35% of jobsite waste be disposed of as
trash at local land fill sites and transfer stations. Exceptions may be made for certain projects under
certain conditions.
The City of La Quinta is committed to the highest level of environmental respect, to conserving our
precious natural resources and setting an example to provide for a better world for generations to
come. Recycling helps keep reusable resources out of landfills and will also reduce disposal costs.
IMPORTANT: Burrtec Waste & Recycling Services is the City's franchise
hauler. If you choose to self -haul any recyclables or trash, you must
provide copies of all weight tickets and/or receipts from the transfer
station, landfill, or recycler as the job progresses. Clean-up companies
and other haulers are not permitted to haul waste or recyclables from the
City of La Quinta. Self -haul weight tickets should be submitted to:
Renado Gouldlock, District Environmental Coordinator -
rgouldlock@burrtecdesert.com, or faxed to (760) 340-0417, or mailed to:
41575 Eclectic Street, Palm Desert, CA. 92260.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 279 Calculation Date/Time: 14:43, Wed, Oct 10, 2018
CF1 R-PRF-01
Page 1 of 14
Calculation Description: Title 24 Analysis
Input File Name: Hideaway Lot 279-Stracts-Rovner-18.ribd16x
412- • 1 A W1 a 1 t'7
GENERAL INFORMATION
01
Project Name
Hideaway 279
02
Calculation Description
Title 24 Analysis
03
Project Location
Hideaway Lot 279
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.3.1 (1149)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.2
10
Building Type
Single Family
017 Front Orientation (deg/Cardinal)
90
12
Project Scope
Newly Constructed-rV
• 1-T�
Number of Dwelling Units
1
-- -A
14
Total Cond. Floor Area (ft2)
6676
V V
%J 11 V 1 A
Number of Zones
6
16
Slab Area ft2
( )
4995
•
nQ
Number of Stories
3
18
Addition Cond. Floor Area(ft2)
n/a
Natural Gas Available
Yes
20
Addition Slab Area (ft2)
n/a
0 R
IJaN
E
Glazing Percentage (%)
22.7%
COMPLIANCE RESULTS
DATIP
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
2.91
4.26
-1.35
-46.4%
Space Cooling
83.81
86.02
-2.21
-2.6%
IAQ Ventilation
0.82
0.82
0.00
0.0%
Water Heating
246
2.10
0.36
14.6%
Photovoltaic Offset
-14.67
14.67
Compliance Energy Total
90.00
78.53
11.47
1\L.`/1-1 V E�6-dl
APR 2 2 2019
CITY OF LA QUINTA
DESIGN AND DEVELOPMENT DEPARTMENT
Registration Number: 218-P010238564B-000-000-0000000-0000 Registration Date/Time: 2018-10-10 15:00:44 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-10 14:44:57
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 279 Calculation Date/Time: 14:43, Wed, Oct 10, 2018
CF1 R-PRF-01
Page 2 of 14
Calculation Description: Title 24 Analysis
Input File Name: Hideaway Lot 279-Stracts-Rovner-18.ribd16x
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency EDR of Proposed Efficiency
EDR Value of Proposed PV + Battery
Final Proposed EDR
47.8 49.2
12.5
36.7
❑
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
U
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site
photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified.
Notes:
• Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules
ENERGY DESIGN RATING PV SYSTEM INPUTS - DETAILED
DC System Size (kWdc)
Module Type
CFI
Azimuth (deg)
Tilt Input
Array Angle (deg)
Tilt:
(x in 12)
Inverter Eff. (%)
5
Standard
❑
180
deg
22.0
4.8
96
• PV System offsets 25% of the total proposed design kTDV/ft-yr
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• PV System: 5 kWdc
Registration Number: 218-Po10238564B-000-000-0000000-0000 Registration DatefTime: 2018-10-10 15:00:44 HERS Provider:
CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-10 14:44:57
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CFI R-PRF-01
Project Name: Hideaway 279
Calculation Description: Title 24 Analysis
Calculation Date/Time: 14:43, Wed, Oct 10, 2018 Page 3 of 14
Input File Name: Hideaway Lot 279-Stracts-Rovner-18.ribd16x
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer
analysis. Additional detail is
provided in the building components tables below
Building -level Verifications:
• High quality insulation installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow,
• Verified EER
• Verified SEER
• Verified Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
Domestic Hot Water System Verifications:
None --
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Hideaway 279
6676
1
6
6
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Master
Conditioned
HVAC master1
1120
11.5
DHW Sys 1
n/a
living area
Conditioned
HVAC kitchen2
2491
12.5
DHW Sys 1
n/a
Media
Conditioned
HVAC media3
353
10
DHW Sys 1
n/a
Casita Zone
Conditioned
HVAC Casita4
1031
10
DHW Sys 1
n/a
2nd bedroom
Conditioned
HVAC 2nd beds
1355
9
DHW Sys 1
n/a
exercise
Conditioned
HVAC exercise6
326
9
DHW Sys 1
n/a
Registration Number: 219-Po10238564B-000-000-0000000-0000 Registration Date/Time: 2018-10-10 15:00:44 HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-10 14:44:57
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1 R-PRF-01
Project Name: Hideaway 279
Calculation Description: Title 24 Analysis
Calculation Date/Time: 14:43, Wed, Oct 10, 2018 Page 4 of 14
Input File Name: Hideaway Lot 279-Stracts-Rovner-1 8.ribdl 6x
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window & Door Area (ftZ)
Tilt (deg)
N Wall
Master
R-21 Wall (W.21.2x6.16)
0
Right
260
0
90
E Wall
Master I
R-21 Wall (W.21.2x6.16)
90
Front
96
0
90
S Wall
Master
R-21 Wall (W.21 2x6.16)
180
Left
702
53.8
90
W Wall
Master
R-21 Wall (W.21.2x6 16)
270
Back
343
100
90
Interior Surface
Master
R-0 Interior Wall
n/a
n/a
250
0
n/a
Roof
Master
R-38 Roof Attic
n/a
n/a
1120
n/a
n/a
N Wall 2
living area
R-21 Wall (W.21.2x6.16)
0
Right
720
76
90
E Wall 2
living area
R-21 Wall (W.21.2x6.16)
90
Front
580
160
90
S Wall 2
living area
R-21 Wall (W.21.2x6.16)
180
Left
300
108
90
W Wall 2
living area
R-21 Wall (W.21.2x6.16)
270
Back
1056
561.6
90
Interior Surface 2
living area
R-0 Interior Wall
n/a
n/a
450
0
n/a
Roof 2
living area
R-38 Roof Attic
n/a
n/a
2491
n/a
n/a
N Wall 3
Media
R-21 Wall (W.21 2x6.16)
0
Right
300
25
90
E Wall 3
Media
R-21 Wall (W.21.2x6.16)
90
Front
300
0
90
Interior Surface 3
Media
R-0 Interior Wall
n/a
n/a
250
0
n/a
Interior Surface 4
Media
R-0 Interior Wall
n/a
n/a
250
0
n/a
Interior Surface 5
Media
R-0 Interior Wall
n/a
n/a
250
0
n/a
Interior Surface 6
Media
R-0 Interior Wall
n/a
n/a
250
0
n/a
Interior Surface 7
Media
R-0 Interior Wall
n/a
n/a
250
0
n/a
Interior Surface 8
Media
R-0 Interior Wall
n/a
n/a
250
0
n/a
Roof 3
Media
R-38 Roof Attic
n/a
n/a
353
n/a
n/a
N Wall 4
Casita Zone
R-21 Wall (W.21.2x6.16)
0
Right
380
83
90
E Wall 4
Casita Zone
R-21 Wall (W.21.2x6.16)
90
Front
30
0
90
S Wall 3
Casita Zone
R-21 Wall (W.21.2x6.16)
180
Left
430
12
90
W Wall 3
Casita Zone
R-21 Wall (W.21.2x6.16)
270
Back
310
26
90
Interior Surface 9
Casita Zone»living area
R-0 Interior Wall
n/a
n/a
250
0
n/a
Roof 4
Casita Zone
R-38 Roof Attic
n/a
n/a
1031
n/a
n/a
N Wall 5
2nd bedroom
R-21 Wall (W.21.2x6.16)
0
Right
750
37
90
E Wall 5
2nd bedroom
R-21 Wall (W.21.2x6.16)
90
Front
200
25
90
S Wall
2nd bedroom
R-21 Wall (W.21.2x6.16)
180
Left
750
87
90
Registration Number: 218-P010238564B-000-000-0000000-0000 Registration Date/Time: 2018-10-10 15:00:44 HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-10 14:44:57
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 279 Calculation Date/Time: 14:43, Wed, Oct 10, 2018
CF1 R-PRF-01
Page 5 of 14
Calculation Description: Title 24 Analysis
Input File Name: Hideaway Lot 279-Stracts-Rovner-18.ribd16x
W Wall 4
2nd bedroom
R-21 Wall (W.21.2x6.16)
270
Back
200
76
90
Interior Surface 10
2nd bedroom
R-0 Interior Wall
n/a
n/a
450
0
n/a
Roof 5
2nd bedroom
R-38 Roof Attic
n/a
n/a
1355
n/a
n/a
N Wall 6
exercise
R-21 Wall (W.21.2x6.16)
0
Right
200
20
90
E Wall 6
exercise
R-21 Wall (W.21.2x6.16)
90
Front
200
40
90
S Wall 5
exercise
R-21 Wall (W.21.2x6.16)
180
Left
200
46
90
W Wall 5
exercise
R-21 Wall (W.21.2x6.16)
270
Back
200
0
90
Interior Surface 11
exercise
R-0 Interior Wall
n/a
n/a
450
0
n/a
Roof 6
exercise
R-38 Roof Attic
n/a
n/a
326
n/a
n/a
Raised Floor
exercise
R-19 Floor Crawlspace
n/a
n/a
326
n/a
n/a
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Master
Attic RoofMaster
Ventilated
0
0.1
0.85
No
No
Attic living area
Attic Roofliving area
Ventilated
0
0.1
0.85
No
No
Attic Media
Attic RoofMedia
Ventilated
0
0.1
0.85
No
No
Attic Casita Zone
Attic RoofCasita Zone
Ventilated
0
0.1
0.85
No
No
Attic 2nd bedroom
Attic Roof2nd bedroom
Ventilated
0
0.1
0.85
No
No
Attic exercise
' Attic Roofexercise
Ventilated
0
0.1
0.85
No
No
Registration Number: 218-Po10238564B-000-000-0000000-0000 Registration Date/Time: 2018-10-10 15:00:44 HERS Provider:
CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-10 14:44:57
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 279 Calculation Date/Time: 14:43, Wed, Oct 10, 2018
CF1 R-PRF-01
Page 6 of 14
Calculation Description: Title 24 Analysis
Input File Name: Hideaway Lot 279-Stracts-Rovner-18.ribd16x
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(W)
U-factor
SHGC
Exterior Shading
U
Window
S Wall (Left-180)
-•-•
--
1
28.8
0.44
0.24
Insect Screen (default)
T
Window
S Wall (Left-180)
1
12.5
0.44
0.24
Insect Screen (default)
S
Window
S Wall (Left-180)
1
12.5
0.44
0.24
Insect Screen (default)
10
Window
W Wall (Back-270)
1
100.0
0.44
0.24
Insect Screen (default)
P
Window
N Wall 2 (Right-0)
-
1
12.0
0.44
0.24
Insect Screen (default)
N
Window
N Wall 2 (Right-0)
--
1
12.0
0.44
0.24
Insect Screen (default)
M
Window
N Wall 2 (Right-0)
----
----
1
12.0
0.44
0.24
Insect Screen (default)
6
Window
N Wall 2 (Right-0)
....
----
1
24.0
0.44
0.24
Insect Screen (default)
L
Window
N Wall 2 (Right-0)
1
4.0
0.44
0.24
Insect Screen (default)
K
Window
N Wall 2 (Right-0)
-
1
4.0
0.44
0.24
Insect Screen (default)
J
Window
N Wall 2 (Right-0)
-
--
1
4.0
0.44
0.24
Insect Screen (default)
H
Window
N Wall 2 (Right-0)
----
-
1
4.0
0.44
0.24
Insect Screen (default)
B
Window
E Wall 2 (Front-90)
1
30.0
0.44
0.24
Insect Screen (default)
1
Window
E Wall 2 (Front-90)
-
----
1
60.0
0.44
0.24
Insect Screen (default)
A
Window
E Wall 2 (Front-90)
-
1
30.0
0.44
0.24
Insect Screen (default)
CC
Window
E Wall 2 (Front-90)
-
-•
1
16.0
0.44
0.24
Insect Screen (default)
C
Window
S Wall 2 (Left-180)
1
6.0
0.44
0.24
Insect Screen (default)
8
Window
S Wall 2 (Left-180)
-
1
102.0
0.44
0.24
Insect Screen (default)
9
Window
W Wall 2 (Back-270)
--
1
48.0
0.44
0.24
Insect Screen (default)
R
Window
W Wall 2 (Back-270)
----
--
1
240
0.44
0.24
Insect Screen (default)
82
Window
W Wall 2 (Back-270)
-
-
1
339.6
0.44
0.24
Insect Screen (default)
7
Window
W Wall 2 (Back-270)
--
1
100.0
0.44
0.24
Insect Screen (default)
Q
Window
W Wall 2 (Back-270)
----
-
1
50.0
0.44
0.24
Insect Screen (default)
G
Window
N Wall 3 (Right-0)
---
----
1
12.5
0.44
0.24
Insect Screen (default)
F
Window
N Wall 3 (Right-0)
-
--
1
12.5
0.44
0.24
Insect Screen (default)
AA
Window
N Wall 4 (Right-0)
--
-
1
10.0
0.44
0.24
Insect Screen (default)
BB
Window
N Wall 4 (Right-0)
---
1
25.0
0.44
0.24
Insect Screen (default)
13
Window
N Wall 4 (Right-0)
--
1
48.0
0.44
0.24
Insect Screen (default)
V
Window
S Wall 3 (Left-180)
----
----
1
6.0
0.44
0.24
Insect Screen (default)
Registration Number: 218-Po10238564B-000-000-0000000-0000 Registration Date/Time: 2018-10-10 15:00:44 HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-10 14:44:57
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 279 Calculation Date/Time: 14:43, Wed, Oct 10, 2018
CF1 R-PRF-01
Page 7 of 14
Calculation Description: Title 24 Analysis
Input File Name: Hideaway Lot 279-Stracts-Rovner-18.ribdl6x
W
Window
S Wall 3 (Left-180)
-
1
6.0
0.44
0.24
Insect Screen (default)
X
Window
W Wall 3 (Back-270)
-
1
6.0
0.44
0.24
Insect Screen (default)
Y
Window
W Wall 3 (Back-270)
1
10.0
0.44
0.24
Insect Screen (default)
Z
Window
W Wall 3 (Back-270)
--
1
10.0
0.44
0.24
Insect Screen (default)
JJ
Window
N Wall 5 (Right-0)
----
---
1
4.0
0.44
0.24
Insect Screen (default)
HH
Window
N Wall 5 (Right-0)
----
-
1
4.0
0.44
0.24
Insect Screen (default)
GG
Window
N Wall 5 (Right-0)
-
1
4.0
0.44
0.24
Insect Screen (default)
EE
Window
N Wall 5 (Right-0)
---
-
1
25.0
0.44
0.24
Insect Screen (default)
DID
Window
E Wall 5 (Front-90)
---
1
25.0
0-44
0.24
Insect Screen (default)
SS
Window
S Wall 4 (Left-180)
1
12.5
0.44
0.24
Insect Screen (default)
RR
Window
S Wall 4 (Left-180)
--
--
1
12.5
0.44
0.24
Insect Screen (default)
QQ
Window
S Wall 4 (Left-180)
1
6.0
0.44
0.24
Insect Screen (default)
PP
Window
S Wall 4 (Left-180)
-
----
1
12.5
0.44
0.24
Insect Screen (default)
NN
Window
S Wall 4 (Left-180)
-
1
12.5
0.44
0.24
Insect Screen (default)
MM
Window
S Wall 4 (Left-180)
-
1
6.0
0.44
0.24
Insect Screen (default)
LL
Window
S Wall 4 (Left-180)
--
1
12.5
0.44
0.24
Insect Screen (default)
KK
Window
S Wall 4 (Left-180)
----
-
1
12.5
0.44
0.24
Insect Screen (default)
30
Window
W Wall 4 (Back-270)
---
--
1
76.0
0.44
0.24
Insect Screen (default)
UU
Window
N Wall 6 (Right-0)
----
-
1
10.0
0.44
0.24
Insect Screen (default)
TT
Window
N Wall 6 (Right-0)
1
10.0
0.44
0.24
Insect Screen (default)
39
Window
E Wall 6 (Front-90)
----
----
1
40.0
0.44
0.24
Insect Screen (default)
38
Window
S Wall 5 (Left-180)
1
24.0
0.44
0.24
Insect Screen (default)
WW
Window
S Wall 5 (Left-180)
---
--
1
16.0
0.44
0.24 1
Insect Screen (default)
W 2
Window
S Wall 5 (Left-180)
----
--
1
6.0
0.44
0.24 1
Insect Screen (default)
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (ft)
U-factor
14
E Wall 2
24.0
0.50
Registration Number: 218-P010238564B-000-000-0000000-0000 Registration Date/Time: 2018-10-10 15:00:44 HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-10 14:44:57
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 279 Calculation Date/Time: 14:43, Wed, Oct 10, 2018
CF1 R-PRF-01
Page 8 of 14
Calculation Description: Title 24 Analysis
Input File Name: Hideaway Lot 279-Stracts-Rovner-18.ribd16x
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-factor
Assembly Layers
• Around Roof Joists: R-0 0 insul.
• Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofMaster
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing. Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Ceiling Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity/Frame: R-21 /2x6
R-21 Wall (W.21.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.069
Exterior Finish: 3 Coat Stucco
• Inside Finish: Gypsum Board
• Cavity / Frame: no insul. / 2x4
R-0 Interior Wall
Interior Walls
Wood Framed Wall
2x4 @ 16 in. 0 C.
none
0.277
Other Side Finish: Gypsum Board
• Around Roof Joists: R-0.0 insul.
• Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck., Wood Siding/sheathing/decking
Attic Roofliving area
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
• Around Roof Joists: R-0.0 insul.
• Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofMedia
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
• Around Roof Joists: R-0.0 insul.
• Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofCasita Zone
Attic Roofs
Wood Framed Ceiling
in. O C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
• Around Roof Joists: R-0.0 insul.
• Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roof2nd bedroom
Attic Roofs
Wood Framed Ceiling
in. O.0
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
• Around Roof Joists: R-0.0 insul.
• Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck., Wood Siding/sheathing/decking
Attic Roofexercise
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
• Floor Surface: Carpeted
• Floor Deck., Wood Siding/sheathing/decking
R 19 in 5-1/2 in.
Cavity/Frame: R-19 in 5-1/2 in. (R-18) /
R-19 Floor Crawlspace
Exterior Floors
Wood Framed Floor
2x12 @ 16 in. O.C.
cavity (R-18)
0.048
2x12
Registration Number: 218-Po10238564B-000-000-0000000-0000 Registration DateMme: 2018-10-10 15:00:44 HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-10 14:44:57
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 279
Calculation Description: Title 24 Analysis
Calculation Date/Time: 14:43, Wed, Oct 10, 2018
Input File Name: Hideaway Lot 279-Stracts-Rovner-18.ribd16x
C F1 R-PRF-01
Page 9 of 14
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Slab -on -Grade
Master
1120
94
None
0.8
No
Slab -on -Grade 2
living area
2491
145
None
0.8
No
Slab -on -Grade 3
Media
353
26
None
0.8
No
Slab -on -Grade 4
Casita Zone
1031
94
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
n/a
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Standard
DHW Heater 1 (2)
2
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Name I
Heater
Element
Type
Tank Type
Number
of Units
Tank
Volume
(gal)
Uniform Energy
Factor / Energy
Factor / Efficiency
Input Rating /
Pilot /
Thermal
Efficiency
Tank
Insulation
R-value
(Int/Ext)
Standby
Loss /
Recovery
Eff
First Hour
Rating /
Flow Rate
NEEA Heat Pump
Brand / Model /
Other
Tank Location
or Ambient
Condition
DHW Heater 1
Gas
Small
Instantaneous
2
0
0.96 EF
<= 200 kBtu/hr
R-0/R-0
0
n/a
n/a
n!a
Registration Number: 218-P010238564B-000-000-0000000-0000 Registration Date/Time: 2018-10-10 15:00:44 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-10 14:44:57
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 279 Calculation Date/Time: 14:43, Wed, Oct 10, 2018
Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 279-Stracts-Rovner-1 8.ribdl 6x
CF1 R-PRF-01
Page 10 of 14
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC masted
Other He ti stemd Cooling
Y
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC kitchen2
Other Heating and Cooling
System
Heating Component 2
Cooling Component 2
HVAC Fan 2
Air Distribution System 2
HVAC media3
Other Heating and Cooling
System
Heating Component 3
Cooling Component 3
HVAC Fan 3
Air Distribution System 3
HVAC Casita4
Other He ti sg and Cooling
Y
Heating Component 4
Cooling Component 4
HVAC Fan 4
Air Distribution System 4
HVAC 2nd bed5
Other Heating ad Cooling
System
Heating Component 5
Cooling Component 5
HVAC Fan 5
Air Distribution System 5
HVAC exercise6
Heat Pump Heating and
Cooling System
Heat Pump System 6
Heat Pump System 6
HVAC Fan 6
Air Distribution S stem 6
Y
HVAC - HEATING UNIT TYPES
01
Name
Heating Component 1
Heating Component 2
Heating Component 3
Heating Component 4
Heating Component 5
HVAC - HEAT PUMPS
01
Name
Heat Pump System 6
02
03
04
System Type
Number of Units
Efficiency
CntrlFurnace
1
80 AFUE
CntrlFurnace
2
80 AFUE
CntrlFurnace
1
80 AFUE
CntrlFurnace
1
80 AFUE
CntrlFurnace
1
80 AFUE
02
03
04 1 05 06
07 08
09
10
11
System
Number of
Heating
Cooling
Zonally
Compressor
HERS
HSPF/COP
Cap47
Cap 17
SEER
EER
Type
Units
Controlled
Type
Verification
SplitHeatPump
1
I
10
21600
11500
192
14
Not Zonal
Single Speed
Heat Pump System
6-hers-cool
Registration Number: 218-P010238564B-000-000-0000000-0000 Registration Date/Time: 2018-10-10 15:00:44 HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-10 14:44:57
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 279 Calculation Date/Time: 14:43, Wed, Oct 10, 2018
CF1 R-PRF-01
Page 11 of 14
Calculation Description: Title 24 Analysis
Input File Name: Hideaway Lot 279-Stracts-Rovner-18.ribd16x
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
08
Efficiency
Name
System Type
Number of Units
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
1
13
16
Not Zonal
Single Speed
Cooling Component
1-hers-cool
Cooling Component 2
SplitAirCond
2
13
16
Not Zonal
Single Speed
Cooling Component
2-hers-cool
Cooling Component 3
SplitAirCond
1
13
16
Not Zonal
Single Speed
Cooling Component
3-hers-cool
Cooling Component 4
SplitAirCond
1
13
16
Not Zonal
Single Speed
Cooling Component
4-hers-cool
Cooling Component 5
SplitAirCond
1
13
16
Not Zonal
Single Speed
Cooling Component
5-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
Cooling Component 2-hers-cool
Required
350
Required
Required
Required
Cooling Component 3-hers-cool
Required
350
Required
Required
Required
Cooling Component 4-hers-cool
Required
350
Required
Required
Required
Cooling Component 5-hers-cool
Required
350
Required
Required
Required
Heat Pump System 6-hers-cool
Required
350
Required
Required
Required
Registration Number: 218-P010238564B-000-000-0000000-0000 Registration Date/Time: 2018-10-10 15:00:44 HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-10 14:44:57
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 279 Calculation Date/Time: 14:43, Wed, Oct 10, 2018
CFI R-PRF-01
Page 12 of 14
Calculation Description: Title 24 Analysis
Input File Name: Hideaway Lot 279-Stracts-Rovner-18.ribd16x
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
1-hers-dist
Air Distribution System 2
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
2-hers-dist
Air Distribution System 3
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
3-hers-dist
Air Distribution System 4
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
4-hers-dist
Air Distribution System 5
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
5-hers-dist
Air Distribution System 6
DuctsAttic
Sealed and tested
8
Attic
None
Air Distribution System
6-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
n/a
Air Distribution System 2-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
n/a
Air Distribution System 3-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
n/a
Air Distribution System 4-hers-dist
Required
50
d
Not Required
Not Required
Not Required
Not Required
n/a
Air Distribution System 5-hers-dist
Required
50
Not Required
Not Required
Not Required
Not Required
n/a
Air Distribution System 6-hers-dist
Required
5.0
Not Required
I Not Required
Not Required
Not Required
n/a
HVAC-FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.58
HVAC Fan 2-hers-fan
HVAC Fan 3
Single Speed PSC Furnace Fan
0.58
HVAC Fan 3-hers-fan
HVAC Fan 4
Single Speed PSC Furnace Fan
0.58
HVAC Fan 4-hers-fan
HVAC Fan 5
Single Speed PSC Furnace Fan
0.58
HVAC Fan 5-hers-fan
HVAC Fan 6
Single Speed PSC Furnace Fan
0.58
HVAC Fan 6-hers-fan
Registration Number: 218-P010238584B-000-000-0000000-0000 Registration Date/Time: 2018-10-10 15:00:44 HERS Provider:
CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-10 14:44:57
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hideaway 279
Calculation Description: Title 24 Analysis
Calculation Date/Time: 14:43, Wed, Oct 10, 2018
Input File Name: Hideaway Lot 279-Stracts-Rovner-18.ribd16x
C F1 R-PRF-01
Page 13 of 14
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
HVAC Fan 2-hers-fan
Required
0.58
HVAC Fan 3-hers-fan
Required
0.58
HVAC Fan 4-hers-fan
Required
0.58
HVAC Fan 5-hers-fan
Required
0.58
HVAC Fan 6-hers-fan
Required
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
119
0.25
Default
0
Required
Registration Number: 218-Po10238564B-000-000-0000000-0000 Registration Date/Time: 2018-10-10 15:00:44 HERS Provider:
CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149 Report Generated at: 2018-10-10 14:44:57
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CFI R-PRF-01
Project Name: Hideaway 279
Calculation Description: Title 24 Analysis
Calculation Date/Time: 14:43, Wed, Oct 10, 2018 Page 14 of 14
Input File Name: Hideaway Lot 279-Stracts-Rovner-1 8.ribdl 6x
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature_
Tim Scott'��
Company:
Signature Date:
Scott Design and Title 24, Inc.
2018-10-10 15:00:44
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Tim Scott
Company:
Date Signed:
Scott Design and Title 24, Inc.
2018-10-10 15:00:44
Address:
License:
77085 Michigan Drive
na
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration
Provider responsibility for the accuracy of the information.
Easy to Verify
at CaICERTS.com
Registration Number: 218-PO10238564B-000-000-0000000-0000 Registration Date/Time: 2018-10-10 15:00:44
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06282018-1149
HERS Provider: CaICERTS inc.
Report Generated at: 2018-10-10 14:44:57