Loading...
BRES2019-023678-495 CALLE TAMPICO DUr�[J VOICE (760) 777-7125 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 10/9/2019 Permit Type/Subtype: BUILDING RESIDENTIAL/DWELLING - SINGLE FAMILY DETACHED Owner: Application Number: BRES2019-0236 DERRYBERRY, KEVIN G. & SHERI L. Property Address: 53531 AVENIDA CARRANZA 53531 AVENIDA CARRANZA APN: 774115013 LA QUINTA, CA 92253 Application Description: DERRYBERRY / CAR -PORT CONVERSION TO MASTER BATH ROOM Property Zoning: Application Valuation: $10,000.00 Applicant: D �09 a Contractor: CARDENAS CONSTRUCTION COMPANY INC CARDENAS CONSTRUCTION COMPANY INC P 0 BOX 1537 P 0 BOX 1537 INDIO, CA 92201 OCT 2019D INDIO, CA 92201 0 CITY OF LA QUINTA (760)393-6617 Llc. No.: 886924 DESIGN & DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 886924 OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_J I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who Wilds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Addre! WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: 5TATE_COMPfNSATIQN ItJ5V8ANCF FUNQ Policy Number: 9034381 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. /£000ft Ifs WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above - mentioned property for inspection purposes. pate; 0 1 �84l*16e (Applicant or Agent) FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT 101-0000-42600 ($125.00) DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, FIRST 100 SF 101-0000-42400 0 $9.48 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, FIRST 100 SF 101-0000-42400 0 $125.00 DESCRIPTION ACCOUNT QTY AMOUNT ADDITION, FIRST 100 SF PC 101-0000-42600 0 $188.92 Total Paid for ADDITION: $198.40 DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES, FIRST 20 101-0000-42403 0 $26.68 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES, FIRST 20 101-0000-42403 0 $26.68 DESCRIPTION ACCOUNT QTY AMOUNT DEVICES, FIRST 20 PC 101-0000-42600 0 $26.68 DESCRIPTION ACCOUNT I QTY AMOUNT DEVICES, FIRST 20 PC 101-0000-42600 n $26.68 Total Paid for ELECTRICAL: $106.72 DESCRIPTION ACCOUNT QTY AMOUNT PLAN CHECK DEPOSIT - ADDITION/REMODEL 101-0000-42600 1 $125.00 Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $125.00 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $26.68 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $26.68 Total Paid for PLUMBING FEES: $53.36 DESCRIPTION ACCOUNT QTY AMOUNT RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 $21.00 Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 DESCRIPTION ACCOUNT QTY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $1.30 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $1.30 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 .� n }r r eNI f,r,, uesrkr —W PERMIT # 13kE, I f —Q PLAN LOCATION: c— 7 Project Address: Ss J J i/ p •tom n l i Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: O S Applicant Name: _ a-- Address: City, ST, Zip: Telephone: Email: o r� Valuation of Project $ Contractor Name: cLeZ New SFD Construction: Address: P.O.f _ / Cn v7 Conditioned Space SF City, St, Zip 2 , .� Garage SF Telephone: 7&a r Patio/Porch SF Email: C .tJe-4 Q ` o. Fire Sprinklers SF State Lie: ! City Bus Lie: Arch/Eng Name: Construction Type: Occupancy: IIII Address: Grading: City, St, Zip Telephone: Bedrooms: Stories: #Units: Email: State Lie: City Bus Lie: Property Owner's Name: r r r New Commercial / Tenant Improvements: Address:53 _ -53 i a Total Building SF City, ST, Zip T c� , Construction Type: Occupancy: Telephone: Email: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 OFFICE USE ONLY # Submittal Req'd Rec'd Plan Sets Structural Cales Truss Cales Title 24 Calcs Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License Date: 9/12/2019 No.: 19-01467-1 Owner: Kevin Derryberry Address: 53-531 Avenida Carranza City: La Quinta Type: Residential Addition < 500 Sq ft Lot # Street No. 53-531 Comments: CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760)771-8515 Street Name Avenida Carranza Email: Jurisdiction: La Quinta Tract #: Sq. Feet APN 175 774-11-5013 RECEIVED SEP 12 2019 CITY OF LA QUINTA DESIGN AND DEVELOPMENT DEPARTMENT 0.."IVIED S Permit No. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement mobile homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less Exempt This certifies that school facility fess imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 175 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued. Fees Paid By: Exempt/Jesus Lara Check No.: Bank Name/Recipient of Certificate Telephone: Funding: Exempt By Scott L. Bailey Superintendent Fee Collected/ Exempted by: Arianne Catano 0 Certificate Fees Due: $0.00 Original Payment(s) Rec'd; $0.00 New Payment Rec'd: $0.00 Over/o:nder: $0.00 NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District(`s) behalf, whichever is earlier. Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL. BUILDING ENERGY ANALYSIS REPORT PROJECT: Derryberry Residence 53531 Avenida Carranza La Quinta, CA 92253 Project Designer:��2O Iq' 02 C, CITY OF DIVISION SION UI A BUILDING REVIEWED FOR CODE COMPLIANCE Report Prepared by: Joan Hacker Insu-form, Inc. 43585 Monterey Avenue, Suite 7 Palm Desert, Ca 92260 760-345-1352 Job Number: Date: 9/9/2019 BY RECEIVED SEP 0 9 2019 CITY OF LA QUINTA DESIGN AND DEVELOPMENT DEPARTMENT The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. TABLE OF CONTENTS Cover Page Table of Contents Form CF-1 R-PRF-01-E Certificate of Compliance Form RMS-1 Residential Measures Summary Form MF-1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary 2 3 10 12 16 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Daterrime: 12:24, Mon, Sep 09, 2019 Calculation Description: Title 24 Analysis Input File Name: Derryberry Exist Addition.ribdl6x r PLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification 03 This building incorporates one or more Special Features shown below CF1 R-PRF-01 Page 1 of 7 ENERGY USE SUMMARY 04 05 06 11 07 08 Energy Use (kTDVIft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement 29.01 29.23 -0.22 -0.8% Space Heating Space Cooling 550.00 549.75 0.25 0.0% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 17.10 17.10 0.00 0.0% 0.00 0.00 Photovoltaic Offset Compliance Energy Total 596.11 596.08 0.03 0.0% REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Window overhangs and/or fins Registration Number: Registration Date[Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-09-09 12:24:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Daterrime: 12:24, Mon, Sep 09, 2019 Calculation Description: Title 24 Analysis Input File Name: Derryberry Exist Addition. ribd I 6x CF1 R-PRF-01 Page 2 of 7 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • --None-- Cooling System Verifications: • -- None -- HVAC Distribution System Verifications: • -- None -- Domestic Hot Water System Verifications: • -- None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Single Fam Detached 1152.6 1 2 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Existing Living I Conditioned Living Zone1 980 9 DHW Sys 1 n/a Addition Living Conditioned Living Zone1 172.6 9 DHW Sys 1 n/a Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-09-09 12:24:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 12:24, Mon, Sep 09, 2019 Calculation Description: Title 24 Analysis Input File Name: Derryberry Exist Addition.ribdl6x CFI R-PRF-01 Page 3 of 7 OPAQUE SURFACES 01 1 02 03 04 05 1 06 07 08 09 10 11 Name Zone Construction Azimuth Orientation Gross Area (ft) Window & Door Area (ft) Tilt (deg) Wall Exception Status Verified Existing Condition Front Wall Existing Living Default Wall 1978 to 1991 135 Front 800 63 90 n/a Existing No Left Wall Existing Living Default Wall 1978 to 1991 225 Left 600 39.984 90 n/a Existing No Rear Wall Existing Living Default Wall 1978 to 1991 315 Back 800 79.968 90 n/a Existing No Right Wall Existing Living Default Wall 1978 to 1991 45 Right 500 39.984 90 n/a Existing No Interior Surface Existing Living>>Addition Living Default Wall 1978 to 19911 1 0 n/a Existing No Front Wall 2 Addition Living R-15 Wall 135 Front 1 0 90 Extension New n/a Left Wall 2 Addition Living R-15 Wall 225 Left 180 0 90 Extension New n/a Rear Wall 2 Addition Living R-15 Wall 315 Back 120 25.9128 90 Extension New n/a Right Wall 2 Addition Living R-15 Wall 45 Right 1 0 90 Extension New n/a Roof 2 Addition Living R-21 Roof 172.6 n/a New n/a OPAQUE SURFACES — Cathedral Ceilings 01 02 03 04 05 06 07 08 09 10 11 12 Name Zone Type Orientation Area (ft2) Skylight Area (f:2) Roof Rise (x in 12) Roof Reflectance Roof Emittance Cool Roof Status Verged Existing Condifion Roof Existing Living Existing Front 980 0 0 0.1 0.85 No Existing No ATTIC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condition Attic Addition Living Attic RoofAddition Living Ventilated 0 0.1 0.85 Yes No New No Registration Number: Registration Date/Tme: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-09-09 12:24:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Daterrime: 12:24, Mon, Sep 09, 2019 Calculation Description: Title 24 Analysis Input File Name: Derryberry Exist Addition.ribdl6x CF1R-PRF-01 Page 4 of 7 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft2) U-factor SHGC Exterior Shading Status Verified Existing Condition Window Front Wall (Front-135) 5.0 5.0 1 25.0 0.71 0.73 Insect Screen (default) Existing No Window 2 Front Wall (Front-135) 3.0 3.0 1 9.0 0.71 0.73 Insect Screen (default) Existing No Window 3 Front Wall (Front-135) 4.0 1 0 1 4.0 0.71 0.73 Insect Screen (default) Existing No Window 4 Front Wall (Front-135) 5.0 5.0 1 1 25.0 0.71 0.73 Insect Screen (default) Existing No Window 5 Left Wall (Left-225) 6.0 6.8 0.98 40.0 0.71 0.73 Insect Screen (default) Existing No Window 6 Rear Walt (Back-315) 6.0 6.8 0.98 40.0 0.71 0.73 Insect Screen (default) Existing No Window 7 Rear Wall (Back-315) 6.0 6.8 0.98 40.0 0.71 0.73 Insect Screen (default) Existing No Window 8 Right Wall (Right-45) 6.0 6.8 0.98 40.0 0.71 0.73 Insect Screen (default) Existing No Window 9 Rear Wall 2 (Back-315) 4.5 5.9 1 0.976 25.9 0.37 1 0.26 Insect Screen (default) New n/a OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up Window 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 2 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 3 2 0.1 2 2 0 0 0 0 1 0 0 0 0 0 Window 4 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 5 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 6 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 7 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 8 1 2 0.1 2 2 0 0 0 1 0 0 0 0 0 0 Window 9 2 0.1 2 2 0 0 0 1 0 0 0 0 0 0 Registration Number: Registration DateMme: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-09-09 12:24:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation DatelTime: 12:24, Mon, Sep 09, 2019 Calculation Description: Title 24 Analysis Input File Name: Derryberry Exist Addition.ribd16x CF1 R-PRF-01 Page 5 of 7 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 ! 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers • Inside Finish: Gypsum Board • Cavity/Frame: R-11 /2x4 Default Wall 1978 to 1991 Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 11 0.110 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board • Cavity/Frame: no insul. /2x6 • Roof Deck: Wood Siding/sheathing/decking Existing Cathedral Ceilings Wood Framed Ceiling 2x6 @ 16 in. O.C. none 0.479 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: R-11 / 2x4 Default Wall 1978 to 19911 Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 11 0.099 Other Side Finish: Gypsum Board • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofAddition Living Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 - Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R-15/2x4 R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 15 0.095 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-21 Roof attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 21 0.045 Over Ceiling Doists: R-11-.9 insul. SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value Carpeted Fraction Heated Status Verified Existing Condition Slab -on -Grade Existing Living 980 68 None 1 No Existing No Slab -on -Grade 2 Addition Living 172.6 130 None 1 No New No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required n/a Registration Number: Registration DateMme: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-09-09 12:24:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Date/Time: 12:24, Mon, Sep 09, 2019 Calculation Description: Title 24 Analysis Input File Name: Denyberry Exist Addition. ribd 1 6x CF1 R-PRF-01 Page 6 of 7 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) Status Verified Existing Condition DHW Sys 1 DHW Standard DHW Heater 1 1 0 Existing No WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Uniform Energy Factor / Energy Factor / Efficiency Input Rating / Pilot / Thermal Efficiency Tank Insulation R-value (IntlExt) Standby Loss / Recovery Eff First Hour Rating / Flow Rate NEEA Heat Pump Brand / Model Tank Location or Ambient Condition DHW Heater 1 Gas Small Storage 1 50 0.6 EF <= 75 kBtu/hr 0 n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 102 03 04 05 06 07 08 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Status Verified Existing Condition Living Zonel Other Heating and Cooling System Heating Component 1 Cooling Component 1 , HVAC Fan 1 Air Distribution System 1 Existing No HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Name Type Duct Leakage Insulation R-value Supply Duct Location Return Duct Location Bypass Duct Status Verified Existing Condition HERS Verification Air Distribution System 1 Ducts located in attic (Ventilated and Unventilated) Existing (not specified) 2.1 Attic Attic None Existing No n/a IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 0.25 Default 0 Not Required Registration Number: Registration Date/Tme: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-09-09 12:24:34 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Fam Detached Calculation Daterrime: 12:24, Mon, Sep 09, 2019 Calculation Description: Title 24 Analysis Input File Name: Derryberry Exist Addition.ribd16x CF1 R-PRF-01 Page 7 of 7 DOCUMENTATION AUTHORS DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Joan Hacker Company: Signatui,Djte: Insu-form. Inc. 9/9/2019 Address: CEA/HERS Certification Identification (If applicable). 43585 Monterey Avenue, Suite 7 City/StateF) rn Desert. Ca 92260 Phone: 760-345-1352 RESPONS'I�B�LE PERSONS DECLARATION STATEMENT I certify the following under penalty of perory, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Company: Date Signed: Address: License: City/State/Zip: Phone: Registration Number: Registration Date/Tme: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-06232018-1149 Report Generated at: 2019-09-09 12:24:34 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Denybeny Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration California Energy Climate Zone Total Cond. Floor Area Addition CA Climate Zone 15 1,153 173 Date 9/9/2019 # of Units 1 Project Address 53531 Avenida Carranza La Quinta INSULATION Construction Type Area Cavity (ff Special Features Status Wall Wood Framed R 11 737 Existing Wall Wood Framed R 11 560 Existing Wall Wood Framed R 11 720 Existing Roof Wood Framed Rafter - no insulation 980 Existing Wall Wood Framed R 11 460 Existing Demising Wood Framed R 11 1 Existing Slab Unheated Slab -on -Grade - no insulation 980 Perim = 68' Existing Wall Wood Framed R 15 1 New FENESTRATION Total Area: -49TGI,,ing Percentage: 21.6% NewlAltered Avers e U Facsar: Orientation Area(ft) U-Fac SHGC Overhang Sidefins Exterior Shades 0.37 Status Front (SE) 63.0 0.710 Left (SM 40.0 0.710 0.73 2.0 none Bug Screen 0.73 2.0 none Bug Screen Existing Existing Rear (NW 80.0 0.710 0.73 2.0 none Bug Screen Existing Right (NE) 40.0 0.710 0.73 2.0 none Bug Screen Existing Rear (NW) 25.9 0.370 0.26 2.0 none Bug Screen New HVAC SYSTEMS ,Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 78% AFUE Split Air Conditioner 12.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status Living Zone Ducted Ducted Attic 2.1 Existing WATER HEATING Qty. T pe Gallons Min. Eff Distribution Status EnergyPro 7.2 by Ene Soft User Number.- 2655 ID: Page 10 of 16 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Denyberry Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 9/9/2019 Project Address 53531 Avenida Carranza La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1,153 Addition r 173 # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Wall Wood Framed R 15 180 New Roof Wood Framed Attic R 21 173 New Wall Wood Framed R 15 94 New Wall Wood Framed R 15 1 New Slab Unheated Slab -on -Grade - no insulation 173 Perim = 130' New FENESTRATION I Total Area: 249 Glazing Percentage: 21.6% NewfAitered Average U-Factor: 0.37 Orientation Area(ft) U-Fac SHGC Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 7.2 by EneMySoft User Number 2655 ID: Page 11 of 16 2016 Low -Rise Residential Mandatory Measures Summary QM Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. 'Exceptions may apply IN. -'--A 111 Inn' 91 Building Envelope Measures: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ftz or less when tested per § 110.6(a)1: NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 101/I.S.2IA440.2011.' § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES § 110.6(b): 110.6-A and 110.6-B for com fiance and must be caulked and/or weatherstri ed. , Air Leakage. Alljoints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, § 110.7: asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110,8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing § 110.8(i): material must meet the requirements of § 110.$ i when the installation of a cool roof is specified on the CF1 R. § 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling: or the weighted average U-factor must not exceed 0.043. Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently auached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gas keted to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exhitra0on as specified in g 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a dywall ceiling.' § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Above Grade Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0,102 or less (R-19 in 2x6 or U- § 150.0(c): factor of 0.074 or less), Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly,' § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.' § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the re Wrements of § 110.$ . Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This § 150.0(g)l: requirement also applies to controlled ventilation crawl 5 ce for buildings com I 'n with the exception to § 150.0(d). Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all § 150.0(g)2: insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation. Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a § 150.0(q): maximum U-factor of 0.58; or the weighted averse U-factor of all fenestration must not exceed 0.58' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)lA: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area § 150.0(e)1 B: and is equieped with a readily accessible, operable, and light-fittinglight-filting damper or combustion -air control devise.' § 150.0(e)1C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a fireboxjacket, when that indoor air is vented to the outside of § 150.0(e)2: the building, are proNbited. Space Conditioning, Water Heating, and Plumbing System Measures: Certification. Heating, ventilation and air conditioning (HVAG) equipment, water heaters, showerheads, faucets, and all other regulated § 110.0-§ 110.3: appliances must be certified by the manufacturer to the Energy_Commission.' § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the § 110.2(b): cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating.* § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat' Water Heating Recirculation Loops Searing Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110.3 c 5. Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs § 110.3(c)7: or other flutings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed. Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli• § 110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt): and pool and spa heaters.' Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)l: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J usfnq design conditions specified in.§ 150.0(h)2. e 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any dryer vent. § 150.0(h)3B: Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's instructions. § 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 314 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures.' § 150.00)26: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve.' § 150.00)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution piping for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the material. § 150.00)3B: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class II vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)1: 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Cor oration (SRCC or by a listing agency that is approved by the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSIISMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)1: (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or Flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts.' Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such toe is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)B: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all o enin s to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core Flex duct must have a non -porous layer between the inner core and outer vapor barrier, Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0 m 11 and Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency. pressure dro , and la beli nq re uirements of § 150.0 rn 12. 2016 Low -Rise Residential Mandatory Measures Summary Duct System Sizing and Air Filter Gri lie Sizing. Space conditioning systems that use forced air ducts to supply cooiing to an occupiable space must have a hole for the placement of a static pressure probe (HSPP). or a permanently installed static pressure probe (PSPP) in the supply plenum. The space conditioning system must also demonstrate airflow z 350 CFM per ton of nominal cooling capacity through the return § 150.0(m)13: grilles, and an air -handling unit fan efficacy s 0.58 WICFM as confirmed by field verification and diagnostic tesling, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for tonally controlled central forced airs sterns: Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(0): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing whale -budding ventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testin , in accordance with Reference Residential Appendix RAU, Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater § 110.4(a): without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric § 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heatih . § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that § 110.4(b)3: will allow all pumps to be set or programmed to run only durin off-peak electric demand OeAoids. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow § 150.0(p): rate, Dieing, filters, and valves' Lighting Measures: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements § 110.9: of§ 110.9: JA8 High Efficacy Light Sources. To qualify as a JAB high efficacy light source for compliance with § 150.0(k), a residential light source must § 110.9(e): be certified to the Energy Commission according to Reference Joint Appendix JAB. § 150.0(k)1 A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished Floor and do not contain a luminaire or § 150.0(k)l B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fans eed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JAB-2016-E light source rated for elevated temperature must be installed by final ins ection in all recessed downli ht luminaires in ceilings. § 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or Exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)l F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150,0 k Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)I G: with Reference Joint Appendix JAB. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix J A8.' § 150.0(k)I H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JAB compliant and must be marked with "JAB-2016-E." § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems: § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.00: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150,0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with scnnfw § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5 , and meets all other re uirements in § 150.0 k 2. Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5 ; and all other requirements in § 150.0(k)2. § 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it Drovides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0k 2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancy sensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JAB. except luminaires in closets less than 70 square feet and luminaires in hallways.' § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently, mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150A(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMCS. Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either § 150.0 3A or with the applicable requirements in &§ 110.9,130.0,130.2,130.0 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0 3B or_§ 150.0 3D must comply with the applicable re ulrements in 110.9, 130.0,130.2,130.4,140.7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site must comply with the a licab;e requirements in §§ 110.9,130.0,130.2,130.4, 140.7, and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of power as determined according to § 130.0(c). § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the appkable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1. 130.4. 140.6, and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the Floor area, permanently installed lighting for the interior common areas in that building must be hiph efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 ercent. The occupant sensors must be capable of turning the li ht fully on and off from all designed paths of in ress and egress, Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the requirements of § 110.10(b) through § 110.10(e). § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1: greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.' § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted a ui ment.' Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical lane.' § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main servicepanel): and a athwa for routing of plumbing from the solar zone to the water -heating system, § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.1D C must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and ermanentl marked as "For Future Solar Electric'. HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Derryberry Residence 9/9/2019 System Name Flo or Area Living Zone 1,153 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 3,696 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan I Air Ducts Supply COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 70,000 43,520 1,079 1,526 42,135 Total Output Btuh 70,000 0 Output Btuh/s ft 60.7 5,632 4.495 Cooling System 0 0 Output per System 58,000 0 0 0 0 Total Output Btuh 58,000 0 0 Total Output Tons 4.8 5,632 4,495 Total Out ut Btuh/s ft 50.3 TOTAL SYSTEM LOAD 1,079 Total Output s ft/Ton 238.5 54,784 51,124 Air System CFM per System 2,210 HVAC EQUIPMENT SELECTION Airflow cfm 2,210 Existing 35,433 19,545 70,000 Airflow cfmfs ft 1.92 Airflow cfmrron 457.2 70,000 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) 35,4331 19,5451 0,00 Outside Air cfm/s ft 1 TIME OF SYSTEM PEAK Jan 1 AM Note: values above given at ARI conditions F Aug 3 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 IF 68 OF 68 IF 98 IF IN wa�Q 10 Outside Air 0 cfm Supply Fan Heating Coil 96 Ir 2,210 cfm ROOM 68 of 70 OF l 1l COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112 / 78 IF 60169 OF 80169 IF 65 / 64 IF T-1 I Outside Air -4 0 cfm Supply Fan Cooling Coil 67 / 65 OF 2,210 cfm 61.4% ROOM 80 / 69 °F 78 ; 68 IF