Loading...
BRES2019-024678-495 CALLE'TAMPICO Tit�p LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Permit Type/Subtype: BUILDING RESIDENTIAL/REMODEL Application Number: BRES2019-0246 Property Address: 78750 NOLAN CIR CIR APN: 604233020 Application Description: DAVIS / 3RD CAR GARAGE CONVERSION Property Zoning: Application Valuation: $15,000.00 Applicant: D ALLICIA DAVIS OCT 0 8 2019 13021 NE 32ND PL BELLEVUE, WA 98005 CITY OF LA QIiINTA DESIGN & DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: _ License No.::CONVA40528101254102398 Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit su s the applicant to a civil penaltyof nat more than five hundred dollars ($500).: as owner of the property, or my employees with wages as their sole mpensatfan, will do the work, and the structure is not Intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he Id not bulId or Improve For the purpose of sale.). as owner of the property, am excfusiveIV contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the �Cp. ytors' State License Law.). am exempt under Sec. . B.&P.C. for this reason uw_Lo � r&1k CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's N Lender's VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/8/2019 Owner: ALLICIA DAVIS 13021 NE 32ND PL BELLEVUE, WA 98005 Contractor: OWNER BUILDER 13021 NE 32ND PL BELLEVUE, WA 98005 (425)785-1116 Llc. No.::CONV:140528101254102398 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier; Policy Number:_ certify that In the performance of the work for which this permit is issued, I sh employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code hall forthwith comply with those provisions. ' A WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct I agree to comply with all city and county ordinances and state laws rela ' to building construction, and hereby authorize representatives of this city to enterup n e above - mentioned property, for inspection purposes. Dat6 Appli or A v Da-F: • 1@/8/2019 Application Number: Property Address: APN: Application Description Property Zoning: Application Valuation: Applicant: ALLICIA DAVIS 13021 NE 32ND PL BELLEVUE, WA 98005 BRES2019-0246 78750 NOLAN CIR CIR 604233020 DAVIS / 3RD CAR GARAGE CONVERSION $15,000.00 Owner: ALLICIA DAVIS 13021 NE 32ND PL BELLEVUE, WA 98005 Contractor: OWNER BUILDER 13021 NE 32ND PL BELLEVUE, WA 98005 (425)785-1116 LIc. No.::CONV:140528101254102398 Detail: DAVIS / CONVERSION OF 3RD CAR GARAGE TO LIVING SPACE. CREATE NEW BEDROOM AND CLOSET. RELOCATE EXISTING WASHER AND DRYER. THIS PERMTI DOES NOT INCLUDE REPLACEMENT OF THE WATER HEATER;OR, FAU, OR ALTERATIONS AT OTHER PORTIONS OF THE DWELLING. 2016 CALIFORNIA BUILDING CODES. DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES, FIRST 20 101-0000-42403 0 $26.68 DESCRIPTION ACCOUNT CITY AMOUNT DEVICES, FIRST 20 PC 101-0000-42600 0 $26.68 Total Paid for ELECTRICAL: $53.36 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN 101-0000-42402 0 $13.34 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN PC 101-0000-42600 0 $5.34 Total Paid for MECHANICAL: $18.68 DESCRIPTION ACCOUNT CITY AMOUNT PLAN CHECK DEPOSIT - ADDITION/REMODEL 101-0000-42600 1 $125.00 Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $125.00 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $13.34 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $13.34 DESCRIPTION ACCOUNT QTY AMOUNT GAS SYSTEM, 1-4 OUTLETS 101-0000-42401 0 $13.34 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 1-4 OUTLETS PC 101-0000-42600 0 $26.68 Total Paid for PLUMBING FEES: $66.70 DESCRIPTION ACCOUNT QTY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($54.43) DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($27.35) DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($19.21) DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($24.01) DESCRIPTION ACCOUNT CITY AMOUNT REMODEL, EA ADDITIONAL 500 SF 101-0000-42400 0 $24.01 DESCRIPTION ACCOUNT CITY AMOUNT REMODEL, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $19.21 DESCRIPTION ACCOUNT QTY ";MOUfUT REMODEL, FIRST 100 SF 101-0000-42400 0 $54.43 DESCRIPTION ACCOUNT CITY AMOUNT REMODEL, FIRST 500 SF PC 101-0000-42600 0 $121.54 DESCRIPTION ACCOUNT CITY AMOUNT REMODEL, FIRST 500 SF PC 101-0000-42600 0 $27.35 Total Paid for REMODEL 2018: $121.54 DESCRIPTION ACCOUNT CITY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $1.95 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $1.95 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 taPERMIT # ���❑l ❑ �i� ('Al WI_)RNI -- PLAN LOCATION: Project Address: Project Description: APN #: Uvc*a O, Y'oo m Applicant Name: Address: City, ST, Zip: Email: � 5 Valuation of Project $ I 78495 CALLE TAM PICO LA QUINTA, CA 92253 760-777-7000 OFFICE USE ONLY # Submittal Required Received Plan Sets Structural Calcs Truss Calcs Title 24 Calcs Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road Date: 10/7/2019 La Quinta, CA 92253 No.: 19-01495-1 (760)771-8515 Owner: Allicia Davis Email: Address: 78-750 Nolan Cir. Jurisdiction: La Quinta City: La Quinta Tract #: Type: New Residential Addition Lot # Street No. Street Name Sq. Feet APN 78-750 Nolan Cir. 187 604-233-020 Comments: 3rd car garage conversion closing access from main house �NrF�ea s x°y°o ��MC,�HyU 7Vt�pp�iA�:e. r7 P"r1ELli y t L srRr y �A a h I'A n1)7� p IN n y Permit No. At the present time, the Desert Sands Unified School District does not collect fees an garages/carports, covered patios/walkways, residential additions under 560 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement mobile homes. it has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fess imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $3.79 X 187 S.F. or $708.73 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued. Fees Paid By: IUD IT/Maria ,n,o Ramirez Check No.: Credit / Debit Card Bank Name/Recipient of Certificate Telephone: 760-219-3068 Funding: Residential By Scott L. Bailey Superintendent Fee Collected/ Exempted by: Arianne Catano Certificate Fees Flue: $708.73 Credit Card Fees Due: $14.17 Original Payment(s) Rec'd: $0.00 New Payment Rec'd: $722.90 Over/Under: $0.00 NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those Mai IVDtMto another public entity authorized to collect them on the District(`s) behalf, whichever is earlier. Notice THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL. OCT 072019 CITY OF LA QUINTA DESIGN AND DEVELOPMENT DEPARTMENT RECEI\/Er OCT 0 r 2 4 CITY OF LA QUIRA DWREFT LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT PROPERTY OWNER'S PACKAGE (760) 777-7012 FAX (760) 777-7011 Disclosures & Forms for Owner -Builders Applying for Construction Permits IMPORTANT! NOTICE TO PROPERTY OWNER Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified at 78-750 NOLAN CIRCLE We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION DIRECTIONS: Read and initial each statement below to signs you understand or verify this information. LD 1. I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. LD 2 I understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. LD 3. I understand as an "Owner -Builder" I am the responsible party of record on the permit. I understand that I may protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my own. LD 4. I understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on permits and contracts. LD 5. I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer" under state and federal law. LD 6. I understand if I am considered an "employer" under state and federal law, I must register with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. LD 7 I understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. LD 8 I understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workmanship or materials. LD 9. I understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1- 800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. LD 10. I am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the party legally and financially responsible for proposed construction activity at the following address: 78-750 NOLAN CIRCLE LD 11. I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern Owner -Builders as well as employers. LD 12. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note: A copy of the property owner's driver's license, form notarization, or other verification acceptable to the agency is required to be presented when the permit is issued to verify the property owner's signature. Signature of property owner [IJGf �llr/� Date: 10-07-19 Note: The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner -Builder. AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder Permit for my project. Scope of Construction Project (or Description of Work): Project Location or Address: Name of Authorized Agent: Address of Authorized Agent: Tel No I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Note: A copy of the owner's driver's license, form notarization, or other verification acceptable to the agency is required to be presented when the permit is issued to verb the property owner's signature. Property Owner's Signature: Date: 10-07_19 I BUILDING ENERGY ANALYSIS REPORT 1 PROJECT: Louisa Davis Garage Conversion 78-750 Nolan Cir. La Quinta, CA 92253 Project Designer: Desert Collaborative Design 74-818 VelieWay, Suite:3 Palm Desert, California 92264 7602193068 Report Prepared by: CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE rMTF.10A/F*ABy Sergio H. Garcia Sergio H. Garcia Design Consultant 0MCE 49-950 Jefferson St., Suite: 219 COPY Indio, Ca 92201 760880-6796 LU > a Job Number: N L1J � �' a 05-2019 N U � S OO o LLl Q Date: 7/26/2019 0 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. TABLE OF CONTENTS Cover Page Table of Contents Form CF-1 R-PRF-01-E Certificate of Complianc Form RMS-1 Residential Measures Summary Form MF-1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Sum 1 4 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFI R-PRF-01 Project Name: Louisa Davis Garage Conversion Calculation Description: Title 24 Analysis Calculation Date/Time: 18:14, Fri, Jul 26, 2019 Page 1 of 10 Input File Name: 05-2019 LOUISA DAVIS GARAGE CONVERSION. ribd16x GENERAL INFORMATION 01 Project Name Louisa Davis Garage Conversion 02 Calculation Description Title 24 Analysis 03 Project Location 78-750 Nolan Cir. 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 180 12 14 16 18 20 Project Scope Total Cond. Floor Area (ftZ) Slab Area (ft) Addition Cond. Floor Area (ftZ) Addition Slab Area (ft) Addition and/or Alteration 1778 1778 0 0 13 15 17 19 21 Number of Dwelling Units Number of Zones Number of Stories Natural Gas Available Glazing Percentage (%) 1 1 1 Yes 19.6% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ftZ-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 2.95 2.88 0.07 2.4% Space Cooling 197.49 195.57 1.92 1.0% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 11.60 11 60 0.00 0.0% Photovoltaic Offset ---- 0.00 0.00 ---- Compliance Energy Total 212.04 210.05 1.99 0.9% REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Window overhangs and/or fins Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-26 18:15:33 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Louisa Davis Garage Conversion Calculation Date/Time: 18:14, Fri, Jul 26, 2019 Page 2 of 10 Calculation Description: Title 24 Analysis Input File Name: 05-2019 LOUISA DAVIS GARAGE CONVERSION.ribd16x HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis Additional detail is provided in the building components tables below. Building -level Verifications: • --None-- Cooling System Verifications: • --None -- -VAC Distribution System Verifications: • --None -- Domestic Hot Water System Verifications: • --None -- BUILDING - FEATURES INFORMATION 01 1 02 Project Name Louisa Davis Garage Conversion ZONE INFORMATION 01 Zone Name Existing Residence Conditioned Floor Area (ft2) 1778 02 Zone Type Conditioned 03 04 05 Number of Dwelling Units Number of Bedrooms Number of Zones 1 3 1 03 04 05 Zone Floor Area Avg. Ceiling HVAC System Name (ft2) Height Existing Whole House1 r 1778 8 06 Number of Ventilation Cooling Systems 0 06 Water Heating System 1 DHW Sys 1 07 Number of Water Heating Systems 1 07 Water Heating System 2 n/a Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-26 18:15:33 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Louisa Davis Garage Conversion Calculation DatelTime: 18:14, Fri, Jul 26, 2019 CF1 R-PRF-01 Page 3 of 10 Calculation Description: Title 24 Analysis Input File Name: 05-2019 LOUISA DAVIS GARAGE CONVERSION. ribd16x OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 11 Name Zone Construction Azimuth Orientation Gross Area (ft) Window & Door Area (ft) Tilt (deg) Wall Exception Status Verified Existing Condition Wall-Front-S. East 3.2'x8' Existing Residence R-11 Wall 135 315 26 10 90 n/a Existing No Wall -Front -South 4.87'x8' Existing Residence R-11 Wall 180 Front 39 15 90 n/a Existing No Wall-Front-S. East 3.2'x8' 2 Existing Residence R-11 Wall 135 315 26 10 90 n/a Existing No Wall -Left -West 3.66'x8' 2 Existing Residence R-11 Wall 270 Left 29 0 90 n/a Existing No Wall -Front -South 2'x8' 2x Existing Residence R-11 Wall 180 Front 16 0 90 n/a Existing No Wall -Left -West 7.65'x8' 2 Existing Residence R-11 Wall 270 Left 61 0 90 n/a Existing No Wall -Front -South 5'x8' 2x Existing Residence R-11 Wall 180 Front 40 30.9999 90 n/a Existing No Wall -Right -East 4'x8' 2x4 Existing Residence R-11 Wall 90 Right 32 15 90 n/a Existing No Wall -Front -South 3.8'x8' Existing Residence R-11 Wall 180 Front 30 10 90 n/a Existing No Wall -Left -West 31.8'x8' 2 Existing Residence R-11 Wall 270 Left 255 30 90 n/a Existing No Wall -Rear -North 3.89'x8' Existing Residence R-11 Wall 0 Back 31 0 90 n/a Existing No Wall-Rear-N.West 3.5'x8' Existing Residence R-11 Wall 315 135 28 15 90 n/a Existing No Wall -Rear -North 6.23'x8' Existing Residence R-11 Wall 0 Back 50 40 90 n/a Existing No Wall-Rear-N. East 3.5'x8' Existing Residence R-11 Wall 45 225 28 15 90 n/a Existing No Wall -Rear -North 34.83'x8' Existing Residence R-11 Wall 0 Back 279 82 90 n/a Existing No Wall -Right -East 39.16'x8' Existing Residence R-11 Wall 90 Right 313 1 40 90 n/a Existing No Wall -Right -East 20.3'x8' Existing Residence R-13 Wall 90 Right 163 20 90 n/a Altered n/a Wall -Front -South 10.7'x8' Existing Residence R-13 Wall 180 Front 86 16 90 n/a Altered n/a Garage to Addition- 24'x8 Existing Residence» Garage_ R-13 Wall1 190.32 0 n/a New n/a Addition to Bedroom#2 7.6 Existing Residence»Existing Residence R-13 Wall1 61 0 n/a Altered n/a Existing Roof Existing Residence R-38 Roof Attic 1591 n/a Existing No Garage Conversion Roof Existing Residence R-38 Roof Attic 187 n/a Altered n/a Garage To Bedroom#1, 22.3 Existing Residence» Garage_ R-11 Roof Attic 178 n/a Existing No Wall-Frontl-South 18.5'x8 _Garage_ R-0 Wall 180 Front 175 112 90 n/a Existing No Wall -Left -West 20.37'x8' _Garage_ R-0 Wall 270 Left 163 17 90 n/a Existing No Existing Roof 2 Garage_ R-0 Roof Attic 401 n/a Existing No Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-26 18:15:33 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Louisa Davis Garage Conversion Calculation Date/Time: 18:14, Fri, Jul 26, 2019 CF1 R-PRF-01 Page 4 of 10 Calculation Description: Title 24 Analysis Input File Name: 05-2019 LOUISA DAVIS GARAGE CONVERSION. ribd16x ATTIC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condition Attic Existing Residence Attic RoofExisting Residence Ventilated 4 0.1 0.85 No No Existing No Attic Garage_ Attic Garage Roof Cons Ventilated 4 01 0.85 No No Existing No Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-26 18:15:33 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Louisa Davis Garage Conversion Calculation Date/Time: 18:14, Fri, Jul 26, 2019 CF1 R-PRF-01 Page 5 of 10 Calculation Description: Title 24 Analysis Input File Name: 05-2019 LOUISA DAVIS GARAGE CONVERSION. ribd16x FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 Verified Existing Name Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft) U-factor SHGC Exterior Shading Status Condition Window#09, 2050 CMT. Wall-Front-S.Eastj2'x8' (- specify 2.0 5.0 1 10.0 0.71 0.73 Insect Screen (default) Existing No Window #08, 3050 CMT Wall -Front -South 4.87'x8' 3.0 5.0 1 150 0.71 0.73 Insect Screen (default) Existing No (Front-180) Window# 07. 2050 CMT. Wall-Front-S. East 3.2'x8' 2 (- 2.0 2.0 2.5 10.0 0.71 0.73 Insect Screen (default) Existing No specify --135) Fr. Dr. G , 3068 Wall -Front -South 5'x8' 2x 1 200 0.71 0.73 Insect Screen (default) Existing No (Front-180) Window #06 4016 Fix Above Wall -Front -South 5'x8' 2x 1 6.0 071 0.73 Insect Screen (default) Existing No (Front-180) Window#5, 83x60 Fix Wall -Front -South 5'x8' 2x 8 6.0 1.004 5.0 071 0.73 Insect Screen (default) Existing No (Front-180) Window#04, 3050 CMT Wall -Right -East 4'x8' 2x4 3.0 5.0 1 15.0 0.71 0.73 Insect Screen (default) Existing No (Right-90) Window#03. 2050 CMT Wall -Front -South 3.8'x8' 2.0 5.0 1 10.0 0.71 0.73 Insect Screen (default) Existing No (Front-180) Window#17, 6040 XO Wall -Left -West 31.8'x8' 2 6.0 4.0 1 24.0 0.71 0.73 Insect Screen (default) Existing No (Left-270) Window#16, 4016 XO Wall -Left -West 31 8'x8' 2 4.0 1.5 1 6.0 0.71 0.73 Insect Screen (default) Existing No (Left-270) Window#15, 3050 Fix Wall-Rear-N.West 3.5'x8' (- specify 3.0 5.0 1 15.0 071 0.73 Insect Screen (default) Existing No --315) Window I . 6068 Fr Dr Wall -Rear -North 6.23'x8' (Back-0) 60 6.7 1.001 40.0 0.71 0.73 Insect Screen (default) Existing No Window#14, 3050 Fix Wall-Rear-N. East 3.5'x8' (- specify 3.0 5.0 1 15.0 0.71 0.73 Insect Screen (default) Existing No Window#13, 4040 Fix Wall -Rear -North 34.83'x8' (Back-0) 4.0 4.0 1 16.0 0.71 0.73 Insect Screen (default) Existing No Window#12. 5052 XO Wall -Rear -North 34.83'x8' (Back-0) 5.0 5.0 1.04 26.0 0.71 0.73 Insect Screen (default) Existing No Window H , 6068 Fr. Dr. Wall -Rear -North 34.83'x8' (Back-0) 6.0 6.7 1.001 40.0 0.71 0.73 Insect Screen (default) Existing No Window#11, 5050 XO Wall -Right -East 39 16'x8' 5.0 5.0 1 25.0 0.71 0.73 Insect Screen (default) Existing No (Right-90) Window#10. 5030 XO Wall -Right -East 39.16'x8' 5.0 3-0 1 15.0 0.71 0.73 Insect Screen (default) Existing No (Right-90) French Dr. A. 3068 Wall -Right -East 20 3'x8' (Right-90) 3.0 67 1 001 200 0.32 0.25 Insect Screen (default) New n/a Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-26 18:15:33 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Louisa Davis Garage Conversion Calculation Date/Time: 18:14, Fri, Jul 26, 2019 CF1 R-PRF-01 Page 6 of 10 Calculation Description: Title 24 Analysis Input File Name: 05-2019 LOUISA DAVIS GARAGE CONVERSION.ribd16x Window#01, 4040 XO Wall -Front -South 10.7'x8' (Front-180) 4.0 4.0 1 16.0 0.32 025 Insect Screen (default) New n/a OPAQUE DOORS 01 02 03 04 05 06 Name Side of Building Area (ft2) U-factor Status Verified Existing Condition OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up Window#09, 2050 CMT. 2 2 4 4 2 0 0 0 0 0 0 0 0 Window #08, 3050 CMT 2 2 4 4 2 I 0 0 0 0 0 0 0 0 Window# 07, 2050 CMT. 2 2 4 4 2 0 0 0 0 0 0 0 0 Window#5, 83x60 Fix 2 2 4 4 2 0 0 0 0 0 0 0 0 Window#04, 3050 CMT 2 2 4 4 2 0 0 0 0 0 0 0 0 Window#03, 2050 CMT 2 2 4 4 2 0 0 0 0 0 0 0 0 Window#17, 6040 XO 2 2 4 4 2 0 0 0 0 0 0 0 0 Window#16, 4016 XO 2 2 4 4 2 0 0 0 0 0 0 0 0 Window#15, 3050 Fix 2 2 4 4 2 0 0 0 0 0 0 0 0 Window I, 6068 Fr. Dr. 2 2 4 4 2 0 0 0 0 0 0 0 0 Window#14, 3050 Fix 2 2 4 4 2 0 0 0 0 0 0 0 0 Window#13, 4040 Fix 2 2 4 4 2 0 0 0 0 0 0 0 0 Window#12, 5052 XO 2 2 4 1 4 2 0 0 0 0 0 0 0 0 Window H, 6068 Fr. Dr, 2 2 4 4 2 0 0 0 0 0 0 0 0 Window#11. 5050 XO 2 2 4 4 2 0 0 0 0 0 0 0 0 Window#10, 5030 XO 2 2 4 4 2 0 0 0 0 0 0 0 0 French Dr. A, 3068 2 2 4 4 2 0 0 0 0 0 0 0 0 Window#01, 4040 XO 2 2 4 4 2 0 0 0 0 0 0 0 0 Registration Number: Registration DatefFime: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-26 18:15:33 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Louisa Davis Garage Conversion Calculation Date/Time: 18:14, Fri, Jul 26, 2019 CFI R-PRF-01 Page 7 of 10 Calculation Description: Title 24 Analysis Input File Name: 05-2019 LOUISA DAVIS GARAGE CONVERSION. ribd16x OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers Ceilings (below • Inside Finish: Gypsum Board R-0 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in O C. none 0.481 Cavity/Frame: no insul. /2x4 • Inside Finish: Gypsum Board • Cavity / Frame: no insul. / 2x6 R-0 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in O.C. none 0.347 Exterior Finish: 3 Coat Stucco • Cavity/Frame: no insul. /2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 • Roof Deck: Wood Siding/sheathing/decking Attic Garage Roof Cons Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 • Roofing: Light Roof (Asphalt Shingle) • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 • Roof Deck: Wood Siding/sheathing/decking Attic RoofExisting Residence Attic Roofs Wood Framed Ceiling in O C. none 0.644 • Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 Over Ceiling Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity/Frame: R-11 /2x4 R-11 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O C. R 11 0.110 Exterior Finish: 3 Coat Stucco • Ceiling Below Finish: Gypsum Board • Cavity/Frame: R-II /2x4 • Floor Deck. Wood Siding/sheathing/decking R-11 Roof Attic Interior Ceilings Wood Framed Ceiling 2x4 @ 24 in. O.0 R 11 0.067 Floor Surface: Carpeted • Inside Finish: Gypsum Board Cavity/Frame: R-13/2x4 R-13 Wall Exterior Walls Wood Framed Wall 2x4 @ 24 in O C R 13 0.097 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board Cavity/Frame: R-13/2x4 R-13 Walll Interior Walls Wood Framed Wall 2x4 @ 24 in O.C. R 13 0.089 Other Side Finish: Gypsum Board SLAB FLOORS 01 02 03 04 05 06 07 08 09 Verified Perimeter Carpeted Existing Name Zone Area (ftZ) (ft) Edge Insul. R-value Fraction Heated Status Condition Slab -on -Grade Existing Residence 1591 191 None 0.8 No I Existing No Garage Conversion Slab -on Existing Residence 187 31 None 0.8 J No I Existing I No Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 HERS Provider: Report Generated at: 2019-07-26 18:15:33 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Louisa Davis Garage Conversion Calculation Date/Time: 18:14, Fri, Jul 26, 2019 CF1 R-PRF-01 Page 8 of 10 Calculation Description: Title 24 Analysis Input File Name: 05-2019 LOUISA DAVIS GARAGE CONVERSION. ribd16x BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction N Status Verified Existing Condition DHW Sys 1 DHW Standard DHW Heater 1 1 0 Existing No WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Input Rating / Tank Standby Heater Tank Uniform Energy Pilot / Insulation Loss / First Hour Tank Location Element Number Volume Factor / Energy Thermal R-value Recovery Rating / NEEA Heat Pump or Ambient Name Type Tank Type of Units (gal) Factor / Efficiency Efficiency (Int/Ext) Eff Flow Rate Brand / Model Condition DHW Heater 1 Gas Small Storage 7 1 50 0.62 EF <= 75 kBtu/hr 0 n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 Distribution Verified Existing SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Name Status Condition Existing Whole Housel Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution Existing No System 1 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R-value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located in attic Existing (not System 1 (Ventilated and specified) 6.0 Attic Attic None Existing No n/a Unventilated) Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-26 18:15:33 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Louisa Davis Garage Conversion Calculation DatelTime: 18:14, Fri, Jul 26, 2019 CF1 R-PRF-01 Page 9 of 10 Calculation Description: Title 24 Analysis Input File Name: 05-2019 LOUISA DAVIS GARAGE CONVERSION.ribdl6x IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 0.25 Default 0 Not Required PROJECT NOTES This report reflects the existing CEC 2016 Enegy Standards until January 01, 2020 at which time the 2018 Standards will become obsolete. IPRP, Intectual Property Rights Protected, 2019, All Rights Reserved Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-26 18:15:33 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Louisa Davis Garage Conversion Calculation Date/Time: 18:14, Fri, Jul 26, 2019 Page 10 of 10 Calculation Description: Title 24 Analysis Input File Name: 05-2019 LOUISA DAVIS GARAGE CONVERSION.ribd16x DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Sergio H. Garcia Company: Signature Date: Sergio H. Garcia Design Consultant 7/26/2019 Address: CEA/HERS Certification Identification (If applicable): 49-950 Jefferson St., Suite: 219 City/Stat zi : Phone: 760880-6796 in1o, Ca 92201 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Desi ner Narne Responsible Designer Signature Mario%mire7 MARIO RAMIREZ Company: Date Signed: Desert Collaborative Design MARIO RAMIREZ Address: License: 74-818 VelieWay, Suite:3 City/statePaPhone: lm Desert, California 92264 7602193068 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-26 18:15:33 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Louisa Davis Garage Conversion Project Address 78-750 Nolan Cir. La Quinta Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 712612019 California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area Addition 1,778 0 # of Units 1 INSULATION Construction Type Cavity Area (ft) Special Features Status Roof Wood Framed Attic R 38 Wall Wood Framed R 11 Wall Wood Framed R 11 Wall Wood Framed R 11 1,591 Existing 16 Existing 24 Existing 16 Existing Wall Wood Framed R 11 29 Existing Wall Wood Framed R 11 16 Existing Wall Wood Framed R 11 61 Existing Wall Wood Framed R 11 9 Existing FENESTRATION I Total Area: 349 Glazing Percentage: 19.6% New/Altered Average U-Factor. 0•32 Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades Status Right (SE) 20.0 0.710 Front (S) 30.0 0.710 0.73 2.0 0.73 2.0 none Bug Screen Existing none Bug Screen Existing Front (S) 26.0 0.710 0.73 none none Bug Screen Existing Right (E) 55.0 0.710 0.73 2.0 none Bug Screen Existing Left (W) 30.0 0.710 0.73 2.0 none Bug Screen Existing Left (NW) 15.0 0.710 0.73 2.0 none Bug Screen Existing Rear (N) 122.0 0.710 0.73 2.0 none Bug Screen Existing Rear (NE) 15.0 0.710 0.73 2.0 none Bug Screen Existing Right (E) 20.0 0.320 0.25 2.0 none Bug Screen New Front (S) 16.0 0.320 0.25 2.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 93% AFUE HVAC DISTRIBUTION Location Heating Split Air Conditioner 13 0 SEER Setback Existing Duct Cooling Duct Location R-Value Status Existing Whole House Ducted Ducted Attic 6.0 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnerqvPro 7.2 U EnerqVSoft User Number.- 30121 ID: 05-2019 Pa e 13 of 21 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Louisa Davis Garage Conversion Project Address 78-750 Nolan Cir, La Quinta Building Type m Single Family ❑ Addition Alone ❑ Multi Family M Existing+ Addition/Alteration California Energy Climate Zone Total Cond. Floor Area Addition CA Climate Zone 15 1,778 0 Date 7/26/2019 # of Units 1 INSULATION Construction Type Cavity Area (ft) Special Features Status Wall Wood Framed R 11 17 Existing Wall Wood Framed R 11 20 Existing Wall Wood Framed R 11 225 Existing Wall Wood Framed R 11 31 Existing Wall Wood Framed R 11 13 Existing Wall Wood Framed R 11 10 Existing Wall Wood Framed R 11 13 Wall Wood Framed R 11 197 FENESTRATION Total Area; 349FGI,,ing Percentage: New/Altered Average U-Factor: Orientation Area ft2 U-Fac SHGC Overhang Sidefins Exterior Shades Existing Existing 0.32 Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Cooling Duct Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnerqvPro 72 U EnerqySoft User Number: 30121 ID: 05-2019 Pa a 14 of 21 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Louisa Davis Garage Conversion Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 7/26/2019 Project Address 78-750 Nolan Cir. La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1,7 Addition 0 # of Units 1 INSULATION Construction Type Cavity Area ftz Special Features Status Wall Wood Framed R 11 273 Existing Demising Wood Framed Attic R 11 161 Existing Slab Unheated Slab -on -Grade no insulation 1,591 Perim = 191' Existing Roof Wood Framed Attic R 38 187 Altered Wall Wood Framed R 13 143 Altered Wall Wood Framed R 13 70 Altered Demising Wood Framed R 13 190 New Demising Wood Framed R 13 61 Altered FENESTRATION I Total Area: 349 Glazing Percentage: 19.6% NewtAltered Average U-Factor: 0.32 Orientation Area a U-Fac SHGC Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Location Heating Cooling Duct Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnervyPro 72 by EnerqySoft User Number: 30121 ID: 05-2019 Paae 15 of 21 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Building Type m Single Family ❑ Addition Alone Date Louisa Davis Garage Conversion ❑ Multi Family m Existing+ Addition/Alteration 7/26/2019 Project Address California Energy Climate Zone Total Cond. Floor Area Addition # of Units 78-750 Nolan Cir. La Quinta CA Climate Zone 15 1,778 0 1 INSULATION Area Construction Type Cavity (ff ) Special Features Status Slab Unheated Slab -on -Grade no insulation 187 Perim = 31' Existing FENESTRATION 1 Total Area: 349 Glazing Percentage: 19•6% New/Altered Average U-Factor: 0.32 Orientation Area(fr) U-Fac SHGC Overhang Sidefins Exterior Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status WATER HEATING Qty, Type Gallons Min. Eff Distribution Status EneravPro 7.2 by E2eiqySoft User Number: 30121 ID: 05-2019 Page 16 a12 r 2016 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. 'Exceptions may apply. (Revised 0412017) Building Envelope Measures: § 110.6(a)l: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft2 or less when tested per NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-2011.' § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES 110.6-A and 110.6-B for compliance and must be caulked and/or weatherstri ed.' § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet therequirements of § 110.8(1) when the installation of a Cool roof is specified on the CF1 R. § 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs, Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043. Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration, Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to plaGing insulation either above or below the roof deck or on top of a drywall ceiling.' § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Above Grade Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U- § 150.0(c): factor of 0.074 or less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembl .' § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.` § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light detedoratfon; and, when installed as part of a heated slab floor, meet the requiriaments of § 11 0.8. § 150.0(g)l: Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This requirement also applies to controlled ventilation crawlspace for buildings complying with the exception to 150.0(d). § 150.0(g)2: Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class 11 vapor retarder must be installed on the conditioned space side of all insulation in all exterior wells, vented attics, and unvented attics with air -permeable insulation. 150.0 § (q)' Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)1A: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)l B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equlwith a readily accessible, operable, and tight -fitting damper or combustion -air control device.' § 150.0(e)l C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the buildin ,are rohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0-§ 110.3: Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the Energy Commission.' § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for su laments heatin .` § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat.' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110.3(6)5. § 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs or otherfittin s on both cold water and hot water lines of water heatim systems to allow for water tank flushing when the valves are closed. § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- ances without an electrical supply voltage connection with pilat lights that consume less than 150 Btu/hr are exempt): and pool and spa heaters' Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)1: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J using design conditions specified in 150.0 h 2. ' ` 2016 Low -Rise Residential Mandatory Measures Summa § 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any dryer vent. § 150.0(h)3B: Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's instructions. § 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures.' § 150.00)2B: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve' § 150.00)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution i in for steam and h dronic heating systems or hot water system must meet the requirements in TABLE 120.3-A.' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the material. § 150.00)3B: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class II vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)1: 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation SRC@ or by a listing agency that is approved by the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certi to the customer, in wrilin , that the insulation meets this re uiremew. CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSIISMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)1. (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 1 81B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air Building cavities and support platforms may contain ducts. Ducts Installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts.' Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such toe is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in alt o enin s to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9. wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas. or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 1 50.0m 11 and Reference Residential Appendix RA3. Air Filtration, Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure drop, and labeling r uirements of 150.0 m 12. _ 2016 Low -Rise Residential Mandatory Measures Summary Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP). or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow z 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy 15 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central forced air stems.' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(o): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing whole -building ventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testing, in accordance with Reference Residential ARpendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating: § 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater. or dedicated suction and return lines, or built-in or buUt-up connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow ali) gips to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. 150.0 Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow § (p)' rate, pipinp. filters, and valves.' Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9.' § 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must be certified to the Energy Commission accordin to Reference Joint A radix JA8. § 150.0(k)1A: Luminatre Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control. or fanspeed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1 C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C. A JA8-2016-E light source rated for elevated temperature must be installed by final ins ection in all recessed downli ht luminaires in call . § 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled _ by vaGM sensors. § 150.0(k)1 F Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0 k Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1 G: with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix JAB.' § 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E." § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with - 4 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5 ; and meets all other requirements in § 150.0 k 2. - Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9. the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5 ; and all other requirements in § 160.0(k)2. § 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it provides the functionali of a dimmer accordi to 110.9, and complies with all other applicable requirements in § 150.0 k 2. CLJ4� 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancy sensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.' § 150.0(k)21_: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMCS. Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either § 1 50.0it 3A or with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0 k 3B or§ 150.0 k 3D must comply with the applicableLequirements. in §§ 110.9 130.0; 130.2, 130.4,140.7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site mustoomply with the applicable requirements in §§ 110.9 130.0 130.2,130.4. 140.7, and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of power as determined according to § 130.0(c). § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in 110.9, 130.0. 130.1, 130.4. 14.0.6, and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: i. Comply with the applicable requirements in §§ 110.9, 130 0, 130.1. 140.6 and 141.0. and 1. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50percent- The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1. application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the req uirements of § 110.10 b th roug h § 110.10 e . § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1: greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percem of the total roof area of the building excluding any skylight area.' § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment.' Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical lane.' § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel), and a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through 11 0.10c must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and permanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Louisa Davis Garage Conversion System Name Existing Whole House Date 7/26/2019 Floor Area 1,778 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation 1 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. CFM Sensible Latent CFM 1,631 33,071 1,363 587 0 2,257 0 0 0 0 0 0 2,257 37,585 1,363 PEAK Heating System Sensible 28,936 Output perSystem 94,000 Total Output Btuh 188,000 Output (Btuh/s ft) 105.7 1,669 CoolinR System 0 Output per System 28,100 0 Total Output Btuh 56,200 0 Total Output Tons 4•7 1,669 Total Output Btuh/s ft 31.6 Total Output s ft/Ton 379.6 32,274 Air System CFM perSystem 1,115 HVAC EQUIPMENT SELECTION Airflow cfm 2,230 Carrier 58MTB100-20 CNP 38HD 2 T 44,973 2,547 188,000 Airflow cfm/s ft) 1.25 Airflow cfm/Ton 476.2 44,973 2,547 188,000 Jan 1 AM Outside Air %) 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Outside Air cfm/s ft 0 00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak 26 OF 67 OF 67 OF Outside Air AP- 0 cfm Supply Fan Heating Coil 2,230 cfm 67 OF 1 r' 114 of ROOM tit:• "t= COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/76OF /6/62°F 76/62°F 55/54°F o OutAir I Supply Fan 0 cfm Cooling Coil 2,230 cfm 76 / 62 OF --F 56 164 OF 46.7% ROOM 75162 OF PlanIT Reprographics From: dtreeme@aol.com Sent: Wednesday, August 28, 2019 10:20 AM To: PlanIT Reprographics Subject: RE: La Quinta Project-Attn Nathan/Danny Hi it shows on the bottom of the PDF file that it is shared?? Please let me know if you still can't open it? Thank you, Michelle Dunn's Desert Landscape & Dunn's Designer Pools From: PlanIT Reprographics <info@planitprintworks.com> Sent: Wednesday, August 28, 2019 9:28 AM To: dtreeme@aol.com. <dtreeme@aol.com> Subject: RE: La Quinta Project-Attn Nathan/Danny Good morning Danny, The link you sent is private, and we are unable to access it. We have requested access, but will be unable to complete this order until we are granted this access to these plans. Thank You, Greg Click the image below to check out Our new Planroom 0 LMIETSIMM info@ lanitre ro ra hics,com www. PLAN ITRE PROGRAPH I C5, com 77738 Flora Road I Palm Desert, CA 92211 P: 760-345-2500 F: 760-345-2599 planlTm-, PR2NTIWORKS From: dtreeme@aol.com. <dtreeme@aol.com> Sent: Tuesday, August 27, 2019 2:35 PM To: PlanIT Reprographics <info planitprintworks.com> Subject: Fwd: La Quinta Project-Attn Nathan/Danny 1 copy please Thank you, Danny Dunn's Desert Landscape & Dunn's Designer Pools P.O. Box 10279, Palm Desert, CA 92255 760-342-6267 - Fax: 760-342-0022 We are "going green', kindly provide emailed invoices & statements for all future billings to d1treeme6aol.com. -----Original Message ----- From: Craig Burchett <csburchett@ mail.com> To: dtreeme <dtreeme@aol.com> Sent: Tue, Aug 27, 2019 1:51 pm Subject: La Quinta Project-Attn Nathan/Danny Ja_quinta_landscape_plans.pdf Hello Nathan/Danny, Please find the attached plans for your review. If I can get a proposal from you as soon as you can, that would be great. If you have any questions please let me know. Thank you for your time! Alana Kind Regards, Craig Burchett President BURCHETT GRADING INC. Po Box 892863 Temecula, CA. 92589 CELL: (951) 538-6424 OFFICE: 951-302-9792 htips://www.burchettgradingiric.com/