BRES2019-024678-495 CALLE'TAMPICO Tit�p
LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Permit Type/Subtype: BUILDING RESIDENTIAL/REMODEL
Application Number: BRES2019-0246
Property Address: 78750 NOLAN CIR CIR
APN: 604233020
Application Description: DAVIS / 3RD CAR GARAGE CONVERSION
Property Zoning:
Application Valuation: $15,000.00
Applicant: D
ALLICIA DAVIS OCT 0 8 2019
13021 NE 32ND PL
BELLEVUE, WA 98005
CITY OF LA QIiINTA
DESIGN & DEVELOPMENT DEPARTMENT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9
{commencing with Section 70001 of Division 3 of the Business and Professions Code, and
my License is in full force and effect.
License Class: _ License No.::CONVA40528101254102398
Date:
Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any
structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the
alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
su s the applicant to a civil penaltyof nat more than five hundred dollars ($500).:
as owner of the property, or my employees with wages as their sole
mpensatfan, will do the work, and the structure is not Intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that he
Id not bulId or Improve For the purpose of sale.).
as owner of the property, am excfusiveIV contracting with licensed contractors to
construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State
License Law does not apply to an owner of property who builds or improves thereon,
and who contracts for the projects with a contractor(s) licensed pursuant to the
�Cp. ytors' State License Law.).
am exempt under Sec. . B.&P.C. for this reason
uw_Lo � r&1k
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's N
Lender's
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 10/8/2019
Owner:
ALLICIA DAVIS
13021 NE 32ND PL
BELLEVUE, WA 98005
Contractor:
OWNER BUILDER
13021 NE 32ND PL
BELLEVUE, WA 98005
(425)785-1116
Llc. No.::CONV:140528101254102398
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My workers' compensation insurance carrier and policy number are:
Carrier; Policy Number:_
certify that In the performance of the work for which this permit is issued, I
sh employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code hall forthwith
comply with those provisions.
' A
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit issued
as a result of this application , the owner, and the applicant, each agrees to, and shall
defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not
commenced within 180 days from date of issuance of such permit, or cessation of work
for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct
I agree to comply with all city and county ordinances and state laws rela ' to building
construction, and hereby authorize representatives of this city to enterup n e above -
mentioned property, for inspection purposes.
Dat6 Appli or A v
Da-F: • 1@/8/2019
Application Number:
Property Address:
APN:
Application Description
Property Zoning:
Application Valuation:
Applicant:
ALLICIA DAVIS
13021 NE 32ND PL
BELLEVUE, WA 98005
BRES2019-0246
78750 NOLAN CIR CIR
604233020
DAVIS / 3RD CAR GARAGE CONVERSION
$15,000.00
Owner:
ALLICIA DAVIS
13021 NE 32ND PL
BELLEVUE, WA 98005
Contractor:
OWNER BUILDER
13021 NE 32ND PL
BELLEVUE, WA 98005
(425)785-1116
LIc. No.::CONV:140528101254102398
Detail: DAVIS / CONVERSION OF 3RD CAR GARAGE TO LIVING SPACE. CREATE NEW BEDROOM AND CLOSET. RELOCATE EXISTING WASHER AND DRYER.
THIS PERMTI DOES NOT INCLUDE REPLACEMENT OF THE WATER HEATER;OR, FAU, OR ALTERATIONS AT OTHER PORTIONS OF THE DWELLING. 2016
CALIFORNIA BUILDING CODES.
DESCRIPTION ACCOUNT CITY AMOUNT
BSAS SB1473 FEE 101-0000-20306 0 $1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES, FIRST 20
101-0000-42403
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES, FIRST 20 PC
101-0000-42600
0
$26.68
Total Paid for ELECTRICAL: $53.36
DESCRIPTION
ACCOUNT
CITY
AMOUNT
VENT FAN
101-0000-42402
0
$13.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
VENT FAN PC
101-0000-42600
0
$5.34
Total Paid for MECHANICAL: $18.68
DESCRIPTION
ACCOUNT
CITY AMOUNT
PLAN CHECK DEPOSIT - ADDITION/REMODEL
101-0000-42600
1 $125.00
Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $125.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FIXTURE/TRAP
101-0000-42401
0
$13.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FIXTURE/TRAP PC
101-0000-42600
0
$13.34
DESCRIPTION
ACCOUNT
QTY
AMOUNT
GAS SYSTEM, 1-4 OUTLETS
101-0000-42401
0
$13.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
GAS SYSTEM, 1-4 OUTLETS PC
101-0000-42600
0
$26.68
Total Paid for PLUMBING FEES: $66.70
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RECORDS MANAGEMENT FEE
101-0000-42416
0
$10.00
Total Paid for RECORDS MANAGEMENT FEE: $10.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($54.43)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($27.35)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($19.21)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($24.01)
DESCRIPTION
ACCOUNT
CITY
AMOUNT
REMODEL, EA ADDITIONAL 500 SF
101-0000-42400
0
$24.01
DESCRIPTION
ACCOUNT
CITY
AMOUNT
REMODEL, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$19.21
DESCRIPTION
ACCOUNT
QTY
";MOUfUT
REMODEL, FIRST 100 SF
101-0000-42400
0
$54.43
DESCRIPTION
ACCOUNT
CITY
AMOUNT
REMODEL, FIRST 500 SF PC
101-0000-42600
0
$121.54
DESCRIPTION
ACCOUNT
CITY
AMOUNT
REMODEL, FIRST 500 SF PC
101-0000-42600
0
$27.35
Total Paid for REMODEL 2018: $121.54
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SMI - RESIDENTIAL
101-0000-20308
0
$1.95
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $1.95
DESCRIPTION
ACCOUNT
CITY AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0 $5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
taPERMIT # ���❑l ❑ �i�
('Al WI_)RNI --
PLAN LOCATION:
Project Address: Project Description:
APN #:
Uvc*a O, Y'oo m
Applicant Name:
Address:
City, ST, Zip:
Email: �
5
Valuation of Project $ I
78495 CALLE TAM PICO
LA QUINTA, CA 92253
760-777-7000
OFFICE USE ONLY
#
Submittal Required Received
Plan Sets
Structural Calcs
Truss Calcs
Title 24 Calcs
Soils Report
Grading Plan (PM10)
Landscape Plan
Subcontractor List
Grant Deed
HOA Approval
School Fees
Burrtec Debris Plan
Planning approval
Public Works approval
Fire approval
City Business License
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road
Date: 10/7/2019 La Quinta, CA 92253
No.: 19-01495-1 (760)771-8515
Owner: Allicia Davis Email:
Address: 78-750 Nolan Cir. Jurisdiction: La Quinta
City: La Quinta Tract #:
Type: New Residential Addition
Lot # Street No. Street Name Sq. Feet APN
78-750 Nolan Cir. 187 604-233-020
Comments: 3rd car garage conversion closing access from main house
�NrF�ea s
x°y°o
��MC,�HyU 7Vt�pp�iA�:e. r7
P"r1ELli y
t
L srRr y
�A a
h I'A
n1)7�
p IN n y
Permit No.
At the present time, the Desert Sands Unified School District does not collect fees an garages/carports, covered patios/walkways, residential additions
under 560 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement
mobile homes. it has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fess imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $3.79 X 187 S.F. or $708.73 have been paid for the property listed above and that building permits
and/or Certificates of Occupancy for this square footage in the proposed project may now be issued.
Fees Paid By: IUD IT/Maria ,n,o Ramirez Check No.: Credit / Debit Card
Bank Name/Recipient of Certificate Telephone: 760-219-3068
Funding: Residential
By Scott L. Bailey
Superintendent
Fee Collected/ Exempted by: Arianne Catano Certificate Fees Flue: $708.73
Credit Card Fees Due: $14.17
Original Payment(s) Rec'd: $0.00
New Payment Rec'd: $722.90
Over/Under: $0.00
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you may protest the fees or
other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those Mai
IVDtMto another public entity authorized to collect them on the District(`s) behalf, whichever is earlier.
Notice THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL.
OCT 072019
CITY OF LA QUINTA
DESIGN AND DEVELOPMENT DEPARTMENT
RECEI\/Er
OCT 0 r 2 4
CITY OF LA QUIRA
DWREFT
LA QUINTA, CALIFORNIA 92247-1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
BUILDING & SAFETY DEPARTMENT
PROPERTY OWNER'S PACKAGE
(760) 777-7012
FAX (760) 777-7011
Disclosures & Forms for Owner -Builders Applying for Construction Permits
IMPORTANT! NOTICE TO PROPERTY OWNER
Dear Property Owner:
An application for a building permit has been submitted in your name listing yourself as the builder of the property
improvements specified at 78-750 NOLAN CIRCLE
We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of your
responsibilities and possible risk you may incur by having this permit issued in your name as the
Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision,
signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice
unless you, the property owner, obtain the prior approval of the permitting authority.
OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION
DIRECTIONS: Read and initial each statement below to signs you understand or verify this information.
LD 1. I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder"
building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as
an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person
and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those
injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers
on my property.
LD 2 I understand building permits are not required to be signed by property owners unless they are responsible for the
construction and are not hiring a licensed Contractor to assume this responsibility.
LD 3. I understand as an "Owner -Builder" I am the responsible party of record on the permit. I understand that I may protect
myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my
own.
LD 4. I understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on
permits and contracts.
LD 5. I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value
of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer"
under state and federal law.
LD 6. I understand if I am considered an "employer" under state and federal law, I must register with the state and federal
government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment
compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial
risk.
LD 7 I understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential
structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed
subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed
under contract with a licensed general building Contractor.
LD 8 I understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any
financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the
workmanship or materials.
LD 9. I understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue
Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California
Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-
800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors.
LD 10. I am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the
party legally and financially responsible for proposed construction activity at the following address:
78-750 NOLAN CIRCLE
LD 11. I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all
applicable laws and requirements that govern Owner -Builders as well as employers.
LD 12. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I
have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with
someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss
you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also
important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working
on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors,
you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers'
compensation insurance coverage.
Before a building permit can be issued, this form must be completed and signed by the property owner and returned to
the agency responsible for issuing the permit. Note: A copy of the property owner's driver's license, form notarization, or
other verification acceptable to the agency is required to be presented when the permit is issued to verify the property
owner's signature.
Signature of property owner [IJGf �llr/� Date: 10-07-19
Note: The following Authorization Form is required to be completed by the property owner only when designating
an agent of the property owner to apply for a construction permit for the Owner -Builder.
AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF
Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize
the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder
Permit for my project.
Scope of Construction Project (or Description of Work):
Project Location or Address:
Name of Authorized Agent:
Address of Authorized Agent:
Tel No
I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above
information and certify its accuracy. Note: A copy of the owner's driver's license, form notarization, or other verification
acceptable to the agency is required to be presented when the permit is issued to verb the property owner's signature.
Property Owner's Signature: Date: 10-07_19
I BUILDING ENERGY ANALYSIS REPORT 1
PROJECT:
Louisa Davis Garage Conversion
78-750 Nolan Cir.
La Quinta, CA 92253
Project Designer:
Desert Collaborative Design
74-818 VelieWay, Suite:3
Palm Desert, California 92264
7602193068
Report Prepared by:
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
rMTF.10A/F*ABy
Sergio H. Garcia
Sergio H. Garcia Design Consultant
0MCE
49-950 Jefferson St., Suite: 219
COPY
Indio, Ca 92201
760880-6796
LU
>
a
Job Number:
N
L1J �
�' a
05-2019
N
U �
S OO
o
LLl
Q
Date:
7/26/2019
0
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards.
This program developed by EnergySoft Software — www.energysoft.com.
TABLE OF CONTENTS
Cover Page
Table of Contents
Form CF-1 R-PRF-01-E Certificate of Complianc
Form RMS-1 Residential Measures Summary
Form MF-1 R Mandatory Measures Summary
HVAC System Heating and Cooling Loads Sum
1
4
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CFI R-PRF-01
Project Name: Louisa Davis Garage Conversion
Calculation Description: Title 24 Analysis
Calculation Date/Time: 18:14, Fri, Jul 26, 2019 Page 1 of 10
Input File Name: 05-2019 LOUISA DAVIS GARAGE CONVERSION. ribd16x
GENERAL INFORMATION
01
Project Name
Louisa Davis Garage Conversion
02
Calculation Description
Title 24 Analysis
03
Project Location
78-750 Nolan Cir.
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.3.1 (1149)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.2
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
180
12
14
16
18
20
Project Scope
Total Cond. Floor Area (ftZ)
Slab Area (ft)
Addition Cond. Floor Area (ftZ)
Addition Slab Area (ft)
Addition and/or Alteration
1778
1778
0
0
13
15
17
19
21
Number of Dwelling Units
Number of Zones
Number of Stories
Natural Gas Available
Glazing Percentage (%)
1
1
1
Yes
19.6%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building DOES NOT require HERS Verification
03 This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04 05 06 07 08
Energy Use (kTDV/ftZ-yr) Standard Design Proposed Design Compliance Margin Percent Improvement
Space Heating
2.95
2.88
0.07
2.4%
Space Cooling
197.49
195.57
1.92
1.0%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water Heating
11.60
11 60
0.00
0.0%
Photovoltaic Offset
----
0.00
0.00
----
Compliance Energy Total
212.04
210.05
1.99
0.9%
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-26 18:15:33
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Louisa Davis Garage Conversion Calculation Date/Time: 18:14, Fri, Jul 26, 2019 Page 2 of 10
Calculation Description: Title 24 Analysis Input File Name: 05-2019 LOUISA DAVIS GARAGE CONVERSION.ribd16x
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis Additional detail is
provided in the building components tables below.
Building -level Verifications:
• --None--
Cooling System Verifications:
• --None --
-VAC Distribution System Verifications:
• --None --
Domestic Hot Water System Verifications:
• --None --
BUILDING - FEATURES INFORMATION
01 1 02
Project Name
Louisa Davis Garage Conversion
ZONE INFORMATION
01
Zone Name
Existing Residence
Conditioned Floor Area (ft2)
1778
02
Zone Type
Conditioned
03 04 05
Number of Dwelling
Units Number of Bedrooms Number of Zones
1 3 1
03 04 05
Zone Floor Area Avg. Ceiling
HVAC System Name (ft2) Height
Existing Whole House1 r 1778 8
06
Number of Ventilation
Cooling Systems
0
06
Water Heating System 1
DHW Sys 1
07
Number of Water
Heating Systems
1
07
Water Heating System 2
n/a
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-26 18:15:33
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Louisa Davis Garage Conversion Calculation DatelTime: 18:14, Fri, Jul 26, 2019
CF1 R-PRF-01
Page 3 of 10
Calculation Description: Title 24 Analysis
Input File Name: 05-2019 LOUISA DAVIS GARAGE CONVERSION. ribd16x
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
10
11
Name
Zone
Construction
Azimuth
Orientation
Gross Area
(ft)
Window & Door
Area (ft)
Tilt
(deg)
Wall
Exception
Status
Verified
Existing
Condition
Wall-Front-S. East 3.2'x8'
Existing Residence
R-11 Wall
135
315
26
10
90
n/a
Existing
No
Wall -Front -South 4.87'x8'
Existing Residence
R-11 Wall
180
Front
39
15
90
n/a
Existing
No
Wall-Front-S. East 3.2'x8' 2
Existing Residence
R-11 Wall
135
315
26
10
90
n/a
Existing
No
Wall -Left -West 3.66'x8' 2
Existing Residence
R-11 Wall
270
Left
29
0
90
n/a
Existing
No
Wall -Front -South 2'x8' 2x
Existing Residence
R-11 Wall
180
Front
16
0
90
n/a
Existing
No
Wall -Left -West 7.65'x8' 2
Existing Residence
R-11 Wall
270
Left
61
0
90
n/a
Existing
No
Wall -Front -South 5'x8' 2x
Existing Residence
R-11 Wall
180
Front
40
30.9999
90
n/a
Existing
No
Wall -Right -East 4'x8' 2x4
Existing Residence
R-11 Wall
90
Right
32
15
90
n/a
Existing
No
Wall -Front -South 3.8'x8'
Existing Residence
R-11 Wall
180
Front
30
10
90
n/a
Existing
No
Wall -Left -West 31.8'x8' 2
Existing Residence
R-11 Wall
270
Left
255
30
90
n/a
Existing
No
Wall -Rear -North 3.89'x8'
Existing Residence
R-11 Wall
0
Back
31
0
90
n/a
Existing
No
Wall-Rear-N.West 3.5'x8'
Existing Residence
R-11 Wall
315
135
28
15
90
n/a
Existing
No
Wall -Rear -North 6.23'x8'
Existing Residence
R-11 Wall
0
Back
50
40
90
n/a
Existing
No
Wall-Rear-N. East 3.5'x8'
Existing Residence
R-11 Wall
45
225
28
15
90
n/a
Existing
No
Wall -Rear -North 34.83'x8'
Existing Residence
R-11 Wall
0
Back
279
82
90
n/a
Existing
No
Wall -Right -East 39.16'x8'
Existing Residence
R-11 Wall
90
Right
313 1
40
90
n/a
Existing
No
Wall -Right -East 20.3'x8'
Existing Residence
R-13 Wall
90
Right
163
20
90
n/a
Altered
n/a
Wall -Front -South 10.7'x8'
Existing Residence
R-13 Wall
180
Front
86
16
90
n/a
Altered
n/a
Garage to Addition- 24'x8
Existing
Residence» Garage_
R-13 Wall1
190.32
0
n/a
New
n/a
Addition to Bedroom#2 7.6
Existing Residence»Existing
Residence
R-13 Wall1
61
0
n/a
Altered
n/a
Existing Roof
Existing Residence
R-38 Roof Attic
1591
n/a
Existing
No
Garage Conversion Roof
Existing Residence
R-38 Roof Attic
187
n/a
Altered
n/a
Garage To Bedroom#1, 22.3
Existing
Residence» Garage_
R-11 Roof Attic
178
n/a
Existing
No
Wall-Frontl-South 18.5'x8
_Garage_
R-0 Wall
180
Front
175
112
90
n/a
Existing
No
Wall -Left -West 20.37'x8'
_Garage_
R-0 Wall
270
Left
163
17
90
n/a
Existing
No
Existing Roof 2
Garage_
R-0 Roof Attic
401
n/a
Existing
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-26 18:15:33
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Louisa Davis Garage Conversion Calculation Date/Time: 18:14, Fri, Jul 26, 2019
CF1 R-PRF-01
Page 4 of 10
Calculation Description: Title 24 Analysis
Input File Name: 05-2019 LOUISA DAVIS GARAGE CONVERSION. ribd16x
ATTIC
01
02
03
04
05
06
07
08
09
10
Name
Construction
Type
Roof Rise
Roof
Reflectance
Roof
Emittance
Radiant
Barrier
Cool
Roof
Status
Verified Existing
Condition
Attic Existing Residence
Attic RoofExisting Residence
Ventilated
4
0.1
0.85
No
No
Existing
No
Attic Garage_
Attic Garage Roof Cons
Ventilated
4
01
0.85
No
No
Existing
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-26 18:15:33
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Louisa Davis Garage Conversion Calculation Date/Time: 18:14, Fri, Jul 26, 2019
CF1 R-PRF-01
Page 5 of 10
Calculation Description: Title 24 Analysis
Input File Name: 05-2019 LOUISA DAVIS GARAGE CONVERSION. ribd16x
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
Verified
Existing
Name
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multiplier
Area (ft)
U-factor
SHGC
Exterior Shading
Status
Condition
Window#09, 2050 CMT.
Wall-Front-S.Eastj2'x8' (- specify
2.0
5.0
1
10.0
0.71
0.73
Insect Screen (default)
Existing
No
Window #08, 3050 CMT
Wall -Front -South 4.87'x8'
3.0
5.0
1
150
0.71
0.73
Insect Screen (default)
Existing
No
(Front-180)
Window# 07. 2050 CMT.
Wall-Front-S. East 3.2'x8' 2 (-
2.0
2.0
2.5
10.0
0.71
0.73
Insect Screen (default)
Existing
No
specify --135)
Fr. Dr. G , 3068
Wall -Front -South 5'x8' 2x
1
200
0.71
0.73
Insect Screen (default)
Existing
No
(Front-180)
Window #06 4016 Fix Above
Wall -Front -South 5'x8' 2x
1
6.0
071
0.73
Insect Screen (default)
Existing
No
(Front-180)
Window#5, 83x60 Fix
Wall -Front -South 5'x8' 2x
8
6.0
1.004
5.0
071
0.73
Insect Screen (default)
Existing
No
(Front-180)
Window#04, 3050 CMT
Wall -Right -East 4'x8' 2x4
3.0
5.0
1
15.0
0.71
0.73
Insect Screen (default)
Existing
No
(Right-90)
Window#03. 2050 CMT
Wall -Front -South 3.8'x8'
2.0
5.0
1
10.0
0.71
0.73
Insect Screen (default)
Existing
No
(Front-180)
Window#17, 6040 XO
Wall -Left -West 31.8'x8' 2
6.0
4.0
1
24.0
0.71
0.73
Insect Screen (default)
Existing
No
(Left-270)
Window#16, 4016 XO
Wall -Left -West 31 8'x8' 2
4.0
1.5
1
6.0
0.71
0.73
Insect Screen (default)
Existing
No
(Left-270)
Window#15, 3050 Fix
Wall-Rear-N.West 3.5'x8' (- specify
3.0
5.0
1
15.0
071
0.73
Insect Screen (default)
Existing
No
--315)
Window I . 6068 Fr Dr
Wall -Rear -North 6.23'x8' (Back-0)
60
6.7
1.001
40.0
0.71
0.73
Insect Screen (default)
Existing
No
Window#14, 3050 Fix
Wall-Rear-N. East 3.5'x8' (- specify
3.0
5.0
1
15.0
0.71
0.73
Insect Screen (default)
Existing
No
Window#13, 4040 Fix
Wall -Rear -North 34.83'x8' (Back-0)
4.0
4.0
1
16.0
0.71
0.73
Insect Screen (default)
Existing
No
Window#12. 5052 XO
Wall -Rear -North 34.83'x8' (Back-0)
5.0
5.0
1.04
26.0
0.71
0.73
Insect Screen (default)
Existing
No
Window H , 6068 Fr. Dr.
Wall -Rear -North 34.83'x8' (Back-0)
6.0
6.7
1.001
40.0
0.71
0.73
Insect Screen (default)
Existing
No
Window#11, 5050 XO
Wall -Right -East 39 16'x8'
5.0
5.0
1
25.0
0.71
0.73
Insect Screen (default)
Existing
No
(Right-90)
Window#10. 5030 XO
Wall -Right -East 39.16'x8'
5.0
3-0
1
15.0
0.71
0.73
Insect Screen (default)
Existing
No
(Right-90)
French Dr. A. 3068
Wall -Right -East 20 3'x8' (Right-90)
3.0
67
1 001
200
0.32
0.25
Insect Screen (default)
New
n/a
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-26 18:15:33
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Louisa Davis Garage Conversion Calculation Date/Time: 18:14, Fri, Jul 26, 2019
CF1 R-PRF-01
Page 6 of 10
Calculation Description: Title 24 Analysis
Input File Name: 05-2019 LOUISA DAVIS GARAGE CONVERSION.ribd16x
Window#01, 4040 XO
Wall -Front -South 10.7'x8'
(Front-180)
4.0 4.0
1 16.0
0.32
025
Insect Screen (default)
New
n/a
OPAQUE DOORS
01
02
03
04
05
06
Name
Side of Building
Area (ft2)
U-factor
Status
Verified Existing Condition
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
Window#09, 2050 CMT.
2
2
4
4
2
0
0
0
0
0
0
0
0
Window #08, 3050 CMT
2
2
4
4
2
I 0
0
0
0
0
0
0
0
Window# 07, 2050 CMT.
2
2
4
4
2
0
0
0
0
0
0
0
0
Window#5, 83x60 Fix
2
2
4
4
2
0
0
0
0
0
0
0
0
Window#04, 3050 CMT
2
2
4
4
2
0
0
0
0
0
0
0
0
Window#03, 2050 CMT
2
2
4
4
2
0
0
0
0
0
0
0
0
Window#17, 6040 XO
2
2
4
4
2
0
0
0
0
0
0
0
0
Window#16, 4016 XO
2
2
4
4
2
0
0
0
0
0
0
0
0
Window#15, 3050 Fix
2
2
4
4
2
0
0
0
0
0
0
0
0
Window I, 6068 Fr. Dr.
2
2
4
4
2
0
0
0
0
0
0
0
0
Window#14, 3050 Fix
2
2
4
4
2
0
0
0
0
0
0
0
0
Window#13, 4040 Fix
2
2
4
4
2
0
0
0
0
0
0
0
0
Window#12, 5052 XO
2
2
4 1
4
2
0
0
0
0
0
0
0
0
Window H, 6068 Fr. Dr,
2
2
4
4
2
0
0
0
0
0
0
0
0
Window#11. 5050 XO
2
2
4
4
2
0
0
0
0
0
0
0
0
Window#10, 5030 XO
2
2
4
4
2
0
0
0
0
0
0
0
0
French Dr. A, 3068
2
2
4
4
2
0
0
0
0
0
0
0
0
Window#01, 4040 XO
2
2
4
4
2
0
0
0
0
0
0
0
0
Registration Number: Registration DatefFime: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-26 18:15:33
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Louisa Davis Garage Conversion Calculation Date/Time: 18:14, Fri, Jul 26, 2019
CFI R-PRF-01
Page 7 of 10
Calculation Description: Title 24 Analysis
Input File Name: 05-2019 LOUISA DAVIS GARAGE CONVERSION. ribd16x
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-factor
Assembly Layers
Ceilings (below
• Inside Finish: Gypsum Board
R-0 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 24 in O C.
none
0.481
Cavity/Frame: no insul. /2x4
• Inside Finish: Gypsum Board
• Cavity / Frame: no insul. / 2x6
R-0 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in O.C.
none
0.347
Exterior Finish: 3 Coat Stucco
• Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
• Roof Deck: Wood Siding/sheathing/decking
Attic Garage Roof Cons
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
• Roofing: Light Roof (Asphalt Shingle)
• Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
• Roof Deck: Wood Siding/sheathing/decking
Attic RoofExisting Residence
Attic Roofs
Wood Framed Ceiling
in O C.
none
0.644
• Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 38
0.025
Over Ceiling Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity/Frame: R-11 /2x4
R-11 Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O C.
R 11
0.110
Exterior Finish: 3 Coat Stucco
• Ceiling Below Finish: Gypsum Board
• Cavity/Frame: R-II /2x4
• Floor Deck. Wood Siding/sheathing/decking
R-11 Roof Attic
Interior Ceilings
Wood Framed Ceiling
2x4 @ 24 in. O.0
R 11
0.067
Floor Surface: Carpeted
• Inside Finish: Gypsum Board
Cavity/Frame: R-13/2x4
R-13 Wall
Exterior Walls
Wood Framed Wall
2x4 @ 24 in O C
R 13
0.097
Exterior Finish: 3 Coat Stucco
• Inside Finish: Gypsum Board
Cavity/Frame: R-13/2x4
R-13 Walll
Interior Walls
Wood Framed Wall
2x4 @ 24 in O.C.
R 13
0.089
Other Side Finish: Gypsum Board
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Verified
Perimeter
Carpeted
Existing
Name
Zone
Area (ftZ)
(ft)
Edge Insul. R-value
Fraction
Heated
Status
Condition
Slab -on -Grade
Existing Residence
1591
191
None
0.8
No
I Existing
No
Garage Conversion Slab -on
Existing Residence
187
31
None
0.8 J
No
I Existing
I No
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149
HERS Provider:
Report Generated at: 2019-07-26 18:15:33
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Louisa Davis Garage Conversion Calculation Date/Time: 18:14, Fri, Jul 26, 2019
CF1 R-PRF-01
Page 8 of 10
Calculation Description: Title 24 Analysis
Input File Name: 05-2019 LOUISA DAVIS GARAGE CONVERSION. ribd16x
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Not Required
Not Required
Not Required
n/a
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
N
Status
Verified Existing
Condition
DHW Sys 1
DHW
Standard
DHW Heater 1
1
0
Existing
No
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Input Rating /
Tank
Standby
Heater
Tank
Uniform Energy
Pilot /
Insulation
Loss /
First Hour
Tank Location
Element
Number
Volume
Factor / Energy
Thermal
R-value
Recovery
Rating /
NEEA Heat Pump
or Ambient
Name
Type
Tank Type
of Units
(gal)
Factor / Efficiency
Efficiency
(Int/Ext)
Eff
Flow Rate
Brand / Model
Condition
DHW Heater 1
Gas
Small Storage
7 1
50
0.62 EF
<= 75 kBtu/hr
0
n/a
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
Distribution
Verified Existing
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Name
Status
Condition
Existing Whole Housel
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution
Existing
No
System 1
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R-value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
Existing (not
System 1
(Ventilated and
specified)
6.0
Attic
Attic
None
Existing
No
n/a
Unventilated)
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-26 18:15:33
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Louisa Davis Garage Conversion Calculation DatelTime: 18:14, Fri, Jul 26, 2019
CF1 R-PRF-01
Page 9 of 10
Calculation Description: Title 24 Analysis
Input File Name: 05-2019 LOUISA DAVIS GARAGE CONVERSION.ribdl6x
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
0
0.25
Default
0
Not Required
PROJECT NOTES
This report reflects the existing CEC 2016 Enegy Standards until January 01, 2020 at which time the 2018 Standards will become obsolete. IPRP, Intectual Property Rights Protected, 2019,
All Rights Reserved
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-26 18:15:33
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Louisa Davis Garage Conversion Calculation Date/Time: 18:14, Fri, Jul 26, 2019 Page 10 of 10
Calculation Description: Title 24 Analysis Input File Name: 05-2019 LOUISA DAVIS GARAGE CONVERSION.ribd16x
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name: Documentation Author Signature:
Sergio H. Garcia
Company: Signature Date:
Sergio H. Garcia Design Consultant 7/26/2019
Address: CEA/HERS Certification Identification (If applicable):
49-950 Jefferson St., Suite: 219
City/Stat zi : Phone: 760880-6796
in1o, Ca 92201
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Desi ner Narne Responsible Designer Signature
Mario%mire7 MARIO RAMIREZ
Company: Date Signed:
Desert Collaborative Design MARIO RAMIREZ
Address: License:
74-818 VelieWay, Suite:3
City/statePaPhone:
lm Desert, California 92264 7602193068
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-07-26 18:15:33
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Louisa Davis Garage Conversion
Project Address
78-750 Nolan Cir. La Quinta
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
712612019
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area Addition
1,778 0
# of Units
1
INSULATION
Construction Type
Cavity
Area
(ft) Special Features Status
Roof Wood Framed Attic R 38
Wall Wood Framed R 11
Wall Wood Framed R 11
Wall Wood Framed R 11
1,591 Existing
16 Existing
24 Existing
16 Existing
Wall Wood Framed R 11
29 Existing
Wall Wood Framed R 11
16 Existing
Wall Wood Framed R 11
61 Existing
Wall Wood Framed R 11
9 Existing
FENESTRATION I Total Area: 349 Glazing Percentage: 19.6% New/Altered Average U-Factor. 0•32
Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades Status
Right (SE) 20.0 0.710
Front (S) 30.0 0.710
0.73 2.0
0.73 2.0
none Bug Screen Existing
none Bug Screen Existing
Front (S) 26.0 0.710
0.73 none
none Bug Screen Existing
Right (E) 55.0 0.710
0.73 2.0
none Bug Screen Existing
Left (W) 30.0 0.710
0.73 2.0
none Bug Screen Existing
Left (NW) 15.0 0.710
0.73 2.0
none Bug Screen Existing
Rear (N) 122.0 0.710
0.73 2.0
none Bug Screen Existing
Rear (NE) 15.0 0.710
0.73 2.0
none Bug Screen Existing
Right (E) 20.0 0.320
0.25 2.0
none Bug Screen New
Front (S) 16.0 0.320
0.25 2.0
none Bug Screen New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling
Min. Eff Thermostat Status
2 Central Furnace 93% AFUE
HVAC DISTRIBUTION
Location Heating
Split Air Conditioner 13 0 SEER Setback Existing
Duct
Cooling Duct Location R-Value Status
Existing Whole House Ducted Ducted Attic 6.0 Existing
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EnerqvPro 7.2 U EnerqVSoft User Number.- 30121
ID: 05-2019 Pa e 13 of 21
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Louisa Davis Garage Conversion
Project Address
78-750 Nolan Cir, La Quinta
Building Type m Single Family ❑ Addition Alone
❑ Multi Family M Existing+ Addition/Alteration
California Energy Climate Zone Total Cond. Floor Area Addition
CA Climate Zone 15 1,778 0
Date
7/26/2019
# of Units
1
INSULATION
Construction Type
Cavity
Area
(ft) Special Features
Status
Wall Wood Framed R 11
17
Existing
Wall Wood Framed R 11
20
Existing
Wall Wood Framed R 11
225
Existing
Wall Wood Framed R 11
31
Existing
Wall Wood Framed R 11
13
Existing
Wall Wood Framed R 11
10
Existing
Wall Wood Framed R 11 13
Wall Wood Framed R 11 197
FENESTRATION Total Area; 349FGI,,ing Percentage: New/Altered Average U-Factor:
Orientation Area ft2 U-Fac SHGC Overhang Sidefins Exterior Shades
Existing
Existing
0.32
Status
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling
Min. Eff Thermostat
Status
HVAC DISTRIBUTION
Location Heating
Cooling
Duct
Duct Location R-Value
Status
WATER HEATING
Qty. Type Gallons Min. Eff Distribution
Status
EnerqvPro 72 U EnerqySoft User Number: 30121
ID: 05-2019
Pa a 14 of 21
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Louisa Davis Garage Conversion
Building Type
m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
7/26/2019
Project Address
78-750 Nolan Cir. La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
1,7
Addition
0
# of Units
1
INSULATION
Construction Type
Cavity
Area
ftz Special Features
Status
Wall Wood Framed R 11
273
Existing
Demising Wood Framed Attic R 11
161
Existing
Slab Unheated Slab -on -Grade no insulation
1,591 Perim = 191'
Existing
Roof Wood Framed Attic R 38
187
Altered
Wall Wood Framed R 13
143
Altered
Wall Wood Framed R 13
70
Altered
Demising Wood Framed R 13
190
New
Demising Wood Framed R 13
61
Altered
FENESTRATION I Total Area: 349 Glazing Percentage: 19.6% NewtAltered Average U-Factor: 0.32
Orientation Area a U-Fac SHGC Overhang Sidefins Exterior Shades Status
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling
Min. Eff Thermostat Status
HVAC DISTRIBUTION
Location Heating
Cooling
Duct
Duct Location R-Value Status
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EnervyPro 72 by EnerqySoft User Number: 30121
ID: 05-2019
Paae 15 of 21
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Louisa Davis Garage Conversion
❑ Multi Family m Existing+ Addition/Alteration
7/26/2019
Project Address
California Energy Climate Zone Total Cond. Floor Area Addition
# of Units
78-750 Nolan Cir. La Quinta
CA Climate Zone 15 1,778 0
1
INSULATION
Area
Construction Type
Cavity (ff ) Special Features
Status
Slab Unheated Slab -on -Grade
no insulation 187 Perim = 31'
Existing
FENESTRATION 1 Total Area: 349 Glazing Percentage: 19•6% New/Altered Average U-Factor:
0.32
Orientation Area(fr) U-Fac
SHGC Overhang Sidefins Exterior Shades
Status
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat
Status
HVAC DISTRIBUTION
Duct
Location Heating
Cooling Duct Location R-Value
Status
WATER HEATING
Qty, Type
Gallons Min. Eff Distribution
Status
EneravPro 7.2 by E2eiqySoft User Number: 30121 ID: 05-2019 Page 16 a12 r
2016 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. 'Exceptions may apply.
(Revised 0412017)
Building Envelope Measures:
§ 110.6(a)l:
Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft2 or less when tested per
NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-2011.'
§ 110.6(a)5:
Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a).
§ 110.6(b):
Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES
110.6-A and 110.6-B for compliance and must be caulked and/or weatherstri ed.'
§ 110.7:
Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
asketed, or weather stripped.
§ 110.8(a):
Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material.
§ 110.8(g):
Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g).
§ 110.8(i):
Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing
material must meet therequirements of § 110.8(1) when the installation of a Cool roof is specified on the CF1 R.
§ 110.80):
Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs,
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043.
Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration, Attic access doors must have permanently attached
§ 150.0(a):
insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited
to plaGing insulation either above or below the roof deck or on top of a drywall ceiling.'
§ 150.0(b):
Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value.
Above Grade Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-
§ 150.0(c):
factor of 0.074 or less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed
value of R-13 in a wood framed assembl .'
§ 150.0(d):
Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.`
§ 150.0(f):
Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light
detedoratfon; and, when installed as part of a heated slab floor, meet the requiriaments of § 11 0.8.
§ 150.0(g)l:
Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This
requirement also applies to controlled ventilation crawlspace for buildings complying with the exception to 150.0(d).
§ 150.0(g)2:
Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class 11 vapor retarder must be installed on the conditioned space side of all
insulation in all exterior wells, vented attics, and unvented attics with air -permeable insulation.
150.0
§ (q)'
Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.'
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 150.0(e)1A:
Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)l B:
Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area
and is equlwith a readily accessible, operable, and tight -fitting damper or combustion -air control device.'
§ 150.0(e)l C:
Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.'
§ 150.0(e)2:
Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of
the buildin ,are rohibited.
Space Conditioning, Water Heating, and Plumbing System Measures:
§ 110.0-§ 110.3:
Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
appliances must be certified by the manufacturer to the Energy Commission.'
§ 110.2(a):
HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.'
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§ 110.2(b):
must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for
compression heating is higher than the cut-off temperature for su laments heatin .`
§ 110.2(c):
Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat.'
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
§ 110.3(c)5:
meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of §
110.3(6)5.
§ 110.3(c)7:
Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs
or otherfittin s on both cold water and hot water lines of water heatim systems to allow for water tank flushing when the valves are closed.
§ 110.5:
Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli-
ances without an electrical supply voltage connection with pilat lights that consume less than 150 Btu/hr are exempt): and pool and spa heaters'
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment
§ 150.0(h)1:
Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA
Manual J using design conditions specified in 150.0 h 2.
' ` 2016 Low -Rise Residential Mandatory Measures Summa
§ 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any
dryer vent.
§ 150.0(h)3B: Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by
manufacturer's instructions.
§ 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank
Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must
be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a
§ 150.00)2A: nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter;
piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to
kitchen fixtures.'
§ 150.00)2B: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof
and non -crushable casing or sleeve'
§ 150.00)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution
i in for steam and h dronic heating systems or hot water system must meet the requirements in TABLE 120.3-A.'
§ 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by
§ 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can
cause degradation of the material.
§ 150.00)3B: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a
Class I or Class II vapor retarder.
Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a
§ 150.0(n)1: 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside
termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr.
§ 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
§ 150.0(n)3: Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification
Corporation SRC@ or by a listing agency that is approved by the Executive Director.
Ducts and Fans Measures:
§ 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a
contractor installs the insulation, the contractor must certi to the customer, in wrilin , that the insulation meets this re uiremew.
CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC
§§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSIISMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or
a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing
§ 150.0(m)1. (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 1 81B or aerosol sealant that
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air Building cavities and support platforms may contain
ducts. Ducts Installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts.'
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
§ 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such toe is used in combination with mastic and draw bands.
§ 150.0(m)3: Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
mastics, sealants, and other requirements specified for duct construction.
§ 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
automatic dampers.
§ 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually operated dampers in alt o enin s to the outside, except combustion inlet and outlet air openings and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
§ 150.0(m)9. wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas. or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation
§ 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 1 50.0m 11 and Reference Residential Appendix RA3.
Air Filtration, Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,
pressure drop, and labeling r uirements of 150.0 m 12.
_ 2016 Low -Rise Residential Mandatory Measures Summary
Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable
space must have a hole for the placement of a static pressure probe (HSPP). or a permanently installed static pressure probe (PSPP) in the
§ 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow z 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy 15 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central
forced air stems.'
Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor
§150.0(o): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of
providing whole -building ventilation.
§ 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic
testing, in accordance with Reference Residential ARpendix RA3.7.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
§ 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heating:
§ 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater. or dedicated
suction and return lines, or built-in or buUt-up connections to allow for future solar heating.
§ 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
will allow ali) gips to be set or programmed to run only during off-peak electric demand periods.
§ 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
150.0 Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
§ (p)' rate, pipinp. filters, and valves.'
Lighting Measures:
§ 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
of § 110.9.'
§ 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must
be certified to the Energy Commission accordin to Reference Joint A radix JA8.
§ 150.0(k)1A: Luminatre Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or
§ 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control. or
fanspeed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)1 C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C. A JA8-2016-E light source rated for
elevated temperature must be installed by final ins ection in all recessed downli ht luminaires in call .
§ 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than
20 kHz.
Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no
§ 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled
_ by vaGM sensors.
§ 150.0(k)1 F Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
must meet the applicable requirements of § 150.0 k
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply
§ 150.0(k)1 G: with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix
JAB.'
§ 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E."
§ 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems'
§ 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually
switched ON and OFF.
§ 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions.
§ 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with -
4 150.0(k).
§ 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it:
§ 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of §
130.5 ; and meets all other requirements in § 150.0 k 2. -
Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the
§ 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9. the Installation Certificate requirements of § 130.4; the EMCS requirements of §
130.5 ; and all other requirements in § 160.0(k)2.
§ 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
provides the functionali of a dimmer accordi to 110.9, and complies with all other applicable requirements in § 150.0 k 2.
CLJ4�
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(k)2J:
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
be controlled by a vacancy sensor.
§ 150.0(k)2K:
Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with
Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.'
§ 150.0(k)21_:
Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A:
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item
§ 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or
EMCS.
Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies,
§ 150.0(k)3B:
and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with
either § 1 50.0it 3A or with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)3C:
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by
150.0 k 3B or§ 150.0 k 3D must comply with the applicableLequirements. in §§ 110.9 130.0; 130.2, 130.4,140.7 and 141.0.
§ 150.0(k)3D:
Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more
vehicles per site mustoomply with the applicable requirements in §§ 110.9 130.0 130.2,130.4. 140.7, and 141.0.
§ 150.0(k)4:
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
power as determined according to § 130.0(c).
§ 150.0(k)5:
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
applicable requirements for nonresidential garages in 110.9, 130.0. 130.1, 130.4. 14.0.6, and 141.0.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A:
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be high efficacy luminaires and controlled by an occupant sensor
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must:
§ 150.0(k)6B:
i. Comply with the applicable requirements in §§ 110.9, 130 0, 130.1. 140.6 and 141.0. and
1. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50percent- The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1.
application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the
req uirements of § 110.10 b th roug h § 110.10 e .
§ 110.10(a)2:
Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d).
Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local
jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet
each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas
§ 110.10(b)1:
greater than 10,000 square feet.
For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250
square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang
of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less
than 15 percem of the total roof area of the building excluding any skylight area.'
§ 110.10(b)2:
Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.'
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)3B:
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone, measured in the vertical lane.'
§ 110.10(b)4:
Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof
dead load and roof live load must be clearly indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for
§ 110.10(c):
routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel), and a pathway for routing of plumbing from the solar zone to the water -heating system.
§ 110.10(d):
Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
11 0.10c must be provided to the occupant.
§ 110.10(e)1:
Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2:
breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or
main circuit location; and permanently marked as "For Future Solar Electric".
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Louisa Davis Garage Conversion
System Name
Existing Whole House
Date
7/26/2019
Floor Area
1,778
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 1
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK COIL HTG.
CFM Sensible Latent CFM
1,631 33,071 1,363 587
0
2,257
0
0 0 0 0
0
2,257
37,585 1,363
PEAK
Heating System
Sensible
28,936
Output perSystem
94,000
Total Output Btuh
188,000
Output (Btuh/s ft)
105.7
1,669
CoolinR System
0
Output per System
28,100
0
Total Output Btuh
56,200
0
Total Output Tons
4•7
1,669
Total Output Btuh/s ft
31.6
Total Output s ft/Ton
379.6
32,274
Air System
CFM perSystem
1,115
HVAC EQUIPMENT SELECTION
Airflow cfm
2,230
Carrier 58MTB100-20 CNP 38HD 2 T
44,973
2,547
188,000
Airflow cfm/s ft)
1.25
Airflow cfm/Ton
476.2
44,973
2,547
188,000
Jan 1 AM
Outside Air %)
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
Outside Air cfm/s ft
0 00
Note: values above given at ARI conditions
Aug 3 PM
HEATING SYSTEM PSYCHROMETRICS
(Airstream Temperatures at Time of Heating Peak
26 OF 67 OF 67 OF
Outside Air AP-
0 cfm Supply Fan Heating Coil
2,230 cfm
67 OF
1 r'
114 of
ROOM
tit:• "t=
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
112/76OF /6/62°F 76/62°F 55/54°F
o
OutAir I
Supply Fan
0 cfm Cooling Coil
2,230 cfm
76 / 62 OF
--F
56 164 OF
46.7% ROOM
75162 OF
PlanIT Reprographics
From: dtreeme@aol.com
Sent: Wednesday, August 28, 2019 10:20 AM
To: PlanIT Reprographics
Subject: RE: La Quinta Project-Attn Nathan/Danny
Hi it shows on the bottom of the PDF file that it is shared?? Please let me know if you still can't open it?
Thank you,
Michelle
Dunn's Desert Landscape & Dunn's Designer Pools
From: PlanIT Reprographics <info@planitprintworks.com>
Sent: Wednesday, August 28, 2019 9:28 AM
To: dtreeme@aol.com. <dtreeme@aol.com>
Subject: RE: La Quinta Project-Attn Nathan/Danny
Good morning Danny,
The link you sent is private, and we are unable to access it. We have requested access, but will be unable to complete
this order until we are granted this access to these plans.
Thank You,
Greg
Click the image below to check out
Our new Planroom
0
LMIETSIMM
info@ lanitre ro ra hics,com
www. PLAN ITRE PROGRAPH I C5, com
77738 Flora Road I Palm Desert, CA 92211
P: 760-345-2500
F: 760-345-2599
planlTm-,
PR2NTIWORKS
From: dtreeme@aol.com. <dtreeme@aol.com>
Sent: Tuesday, August 27, 2019 2:35 PM
To: PlanIT Reprographics <info planitprintworks.com>
Subject: Fwd: La Quinta Project-Attn Nathan/Danny
1 copy please
Thank you,
Danny
Dunn's Desert Landscape & Dunn's Designer Pools
P.O. Box 10279, Palm Desert, CA 92255 760-342-6267 - Fax: 760-342-0022
We are "going green', kindly provide emailed invoices & statements for all future billings to d1treeme6aol.com.
-----Original Message -----
From: Craig Burchett <csburchett@ mail.com>
To: dtreeme <dtreeme@aol.com>
Sent: Tue, Aug 27, 2019 1:51 pm
Subject: La Quinta Project-Attn Nathan/Danny
Ja_quinta_landscape_plans.pdf
Hello Nathan/Danny,
Please find the attached plans for your review. If I can get a proposal from you as soon as you can, that would be
great. If you have any questions please let me know.
Thank you for your time!
Alana
Kind Regards,
Craig Burchett
President
BURCHETT GRADING INC.
Po Box 892863
Temecula, CA. 92589
CELL: (951) 538-6424
OFFICE: 951-302-9792
htips://www.burchettgradingiric.com/