BRES2019-027778-495 CALLE TAMPICO " 0 D VOICE (760) 777-7125
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011
DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 10/28/2019
Permit Type/Subtype: BUILDING RESIDENTIAL/ADDITION Owner:
Application Number: BRES2019-0277 T D DESERT DEV
Property Address: 81743 ANDALUSIA 81570 CARBON ERAS
APN: 764670039 LA QUINTA, CA 0
Application Description: MCCLUSKEY / 61SF ADDITION TO EXPAND KITCHEN
Property Zoning:
Application Valuation: $25,000.00
Applicant: Contractor:
BIG WOOD BUILDERS INC P BIG WOOD BUILDERS INC
73487 GOLD FLOWER ST 73487 GOLD FLOWER ST
PALM DESERT, CA 92260 OCT 2 8 2019D PALM DESERT, CA 92260
(818)822-0575
CITY OF LA QUINTA Llc. No.:984963
DESIGN & DEVELOPMENT DEPARTMENT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9
{commencing with Section 70001 of Division 3 of the Business and Professions Code, and
my License is in full force and effect.
License Class: License No.: 984963
'Contractor -
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any
structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the
alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that he
or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to
construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State
License Law does not apply to an owner of property who builds or improves thereon,
and who contracts for the projects with a contractor(s) licensed pursuant to the
Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's
Lender's Address:
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one ofthe following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
oftW,3700
ar which this permit is issued.
ave and will maintain workers' compensation insurance, as required by
Secof the Labor Code, for the performance of the work for which this permit is
issued. My workers' compensation insurance carrier and policy number are:
Carrier: STATE COMPENSATION INSURANCE FUND Policy Number: 1938953
_ I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I all forthwith
comply with those provisions.
y
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit issued
as a result of this application , the owner, and the applicant, each agrees to, and shall
defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not
commenced within 180 days from date of issuance of such permit, or cessation of work
For 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the,�tr�-
mentioned property for inspection purposes. _ 7
Date: - 10/28/2019
Application Number:
BRES2019-0277
Owner:
Property Address:
81743 ANDALUSIA
T D DESERT DEV
APN:
764670039
81570 CARBONERAS
Application Description:
MCCLUSKEY / 61SF ADDITION TO EXPAND KITCHEN
LA QUINTA, CA 0
Property Zoning:
Application Valuation:
$25,000.00
Applicant:
Contractor:
BIG WOOD BUILDERS INC
BIG WOOD BUILDERS INC
73487 GOLD FLOWER ST
73487 GOLD FLOWER ST
PALM DESERT, CA 92260
PALM DESERT, CA 92260
(818)822-0575
Llc. No.: 984963
---------.--..------------------ .-;"--------. --'--- --'-, --
-- --- -- -- -- -- - - ----- -
Detail: MCCLUSKEY / Ei15F ADDITION TO EXPAND KITCHEN; RELOCATE KITCHEN SINk,ANI� DISHWASHER, RECONSTRUCT ISLAND W/ VEGGIE SINK, NEW
LIGHTING AND RECEII-I'ACLES. 2016 CALIFORNIA BUILDIN&COOES.
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT
CITY
AMOUNT
ADDITION, FIRST 100 SF
101-0000-42400
0
$134.48
DESCRIPTION
ACCOUNT
QTY
AMOUNT
ADDITION, FIRST 100 SF PC
101-0000-42600
0
$188.92
Total Paid for ADDITION 2018: $323.40
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($125.00)
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HOURLY CHARGE - INTERWEST STRUCTURAL PLAN REVIEW
101-0000-42600
1
$125.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HOURLY CHARGE - INTERWEST STRUCTURAL PLAN REVIEW
101-0000-42600
1
$125.00
Total Paid for BLDG CITY STAFF - PER HOUR: $125.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
BSAS SB1473 FEE
101-0000-20306
0
$1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
QTY AMOUNT
Credit Card Fee
101-0000-43505
0 $2.25
Total Paid for Credit Card Fee: $2.25
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES, FIRST 20
101-0000-42403
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
DEVICES, FIRST 20 PC
101-0000-42600
0
$26.68
Total Paid for ELECTRICAL 2018: $53.36
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PLAN CHECK DEPOSIT - ADDITION/REMODEL
101-0000-42600
1
$125.00
Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $125.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FIXTURE/TRAP
101-0000-42401
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FIXTURE/TRAP PC
101-0000-42600
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WATER SYSTEM INST/ALT/REP
101-0000-42401
0
$13.34
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER SYSTEM INST/ALT/REP PC
101-0000-42600
0
$13.34
Total Paid for PLUMBING 2018: $80.04
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RECORDS MANAGEMENT FEE - MAJOR
101-0000-42416
0
$21.00
Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00
DESCRIPTION I
ACCOUNT I
CITY
AMOUNT
SMI - RESIDENTIAL 101-0000-20308 10 $3.25
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $3.25
DESCRIPTION ACCOUNT CITY AMOUNT
TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
(-'A[ IFORNIA
PERMIT #
PLAN LOCATION:
Project Address: 117q2 ANDAL0.9k
Project Description: �i fly
APN #:
Applicant Name: ( w !1?9
Address: 7 Tq 7 77 C')ob4V*V Sf•
City, ST, Zip: d,*, 06 PC-7 0j 2 Z &-40
Telephone: 319 8 2 2 -OS 75
Email: &--;P(4mK ehi' t.,j v C iAr Go
Project Valuation $
J
Contractor Name: t j" (3vi1�J
New SFD Construction:
Address:
Conditioned Space SF
City, St, Zip
Garage SF
Telephone:
Patio/Porch SF
Email:
Fire Sprinklers SF
State Lic: 9 gt{J6 3 City Bus Lic:
Architect/Engineer Name:
Construction Occupancy:
Address:
Grading:
City, St, Zip
Telephone:
Bedrooms:
Stories:
# Units:
Email:
State Lic: City Bus Lic:
Property Owner's Name: J ['11)4(C12,yael
New Commercial / Tenant Improvements:
Address: 91170 dA lvj1 �k
Total Building SF
City, ST, Zip v,y/k G14 91OL573
Construction Type: Occupancy:
Telephone: BQS• — (pip —
CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
OFFICE USE ONLY
#
Submittal
Regpired
Received
Plan Sets
Structural Calcs
Truss Calcs
Title 24 Calcs
CVWD Fire Flow Letter
Soils Report
Grading Plan (PM10)
Landscape Plan
Subcontractor List
Grant Deed
HOA Approval
School Fees
Burrtec Debris Plan
Planning approval
Public Works approval
Fire approval
City Business License
Building Permit Number:
Project Description: small addition
Exempt: 0
(Materials may contain hazardous wastes and
are not subject to recycling provisions)
Construction Debris Management Plan
Plan Submittal Date! 10/23/2019
Job Site Address
81743 Andalusia
Owner's Name
Jill McCluskey
Number, Street, or PO Box
81743 Andalusia
City, State, Postal Code
La Quinta, CA. 92253
Owner's Phone Number
Owner's E-Mail Add
Project Manager's Name
Project Manager's Phone Number
Project Manager's E-mail Address
Builder / Contractor
Number, Street or PO Box
City, State, Postal Code
Project Square Footage
City Approval By
Date of City Approval
N/A
David Wood
818-822-0575
biQwoodconstructionta.amall.corn
Big Wood Builders
73487 Goldflower St
Palm Desert, CA. 92260
Approx. 61 sq ft
Renado Gouldlock/DEC-Burrtec Waste
ifl 1Ig
Materials To Be Discarded:
Product
Tons
Trash
0.25 Not recyclable
Asphalt
0.00 Recyclable
Brick/Block
0.00 1 Recyclable
Cardboard
0.00 Recyclable
Commingled
0.00 Recyclable
Concrete
0.25 Recyclable
Drywall
0.03 Recyclable
Donated / Reuse"
0.00 Recyclable
"Describe Items
Product
Tons
Masonry (broken)
0.00
Plaster
0.07
Scrap Metal
0.00
Tile (floor)
0.01
Tile (root)
0.01
Wood
0.10
Landscape Debris
0.00
Totals: Recycle Trash Projected Diversion:
0.5 0.3 65.28%
I understand it is the property owners responsibility to submit copies of weight tickets or receipts to the District
Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the
Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste is
diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining
materials generated from the first day of the project through the completion of the project in accordance with this plan. This
DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or
demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still
issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the
DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through
bi-monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer
Owner! Developer Project ftnager f Superintendent Date
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
McCLUSKEY RESIDENCE's addition
81743 ANDALUSIA
LA Q U I NTA, CA 92253
Project Designer:
GLS ARCHITECTURE GROUP INC.
74991 JONI DR #9
PALM DESERT, CA 92260
760 340.3528 2-o 19 - O 7`7
CATY OF ►"J'k INTA�
BUILDI (-,, DIVISION
Report Prepared by:
# REVIEWED PUR
CODE
Armando Chavez
COMPLIANCE
DAT��
44890 SEELEY
LA QUINTA, CA 92253
d� GvPY
760 278.1840
U
C" a
o
N
Job Number: W
s
UU�
19-GLS/070-048
U
o
Date:
6/17/2019
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards.
This program developed by EnergySoft Software — www.energysoft.com.
i*#
I TABLE OF CONTENTS I
Cover Page
Table of Contents
Form CF-1 R-PRF-01-E Certificate of Compliance
Form RMS-1 Residential Measures Summary
Form MF-1 R Mandatory Measures Summary
1
2
3
13
14
I EnergyPro 7.1 by EnergySoft Job Number: ID: 19 - GLS / 070 - 048 User Number: 20648 1
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: McCLUSKEY RESIDENCE Calculation Date/Time: 16:33, Mon, Jun 17, 2019
CF1 R-PRF-01
Page 1 of 10
Calculation Description: Title 24 Analysis
Input File Name: 050 - 81743 ANDALUSIA.ribd16x
GENERAL INFORMATION
01
Project Name
McCLUSKEY RESIDENCE
02
Calculation Description
Title 24 Analysis
03
Project Location
81743 ANDALUSIA
04
City
LA QUINTA
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.3.1 (1149)
08
Climate Zone
CZ15
09
Software Version
CBECC-Res 2016.3.1 (1019)
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
45
12
Project Scope
Addition and/or Alteration
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft2)
3608
15
Number of Zones
2
16
Slab Area (ft2)
3608
17
Number of Stories
1
18
Addition Cond. Floor Area (ft2)
61
19
Natural Gas Available
Yes
r2O
Addition Slab Area (ft)
61
21
Glazing Percentage (%)
15.6%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building DOES NOT require HERS Verification
03
This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
3.80
4.15
-0.35
-9.2%
Space Cooling
145.45
144.86
0.59
0.4%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water Heating
7.47
7.47
0.00
0.0%
Photovoltaic Offset
---
0.00
0.00
—
Compliance Energy Total
156.72
156.48
0.24
0.2%
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
- Window overhangs and/or fins
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149
HERS Provider:
Report Generated at: 2019-06-17 16:34:09
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: McCLUSKEY RESIDENCE Calculation Date/Time: 16:33, Mon, Jun 17, 2019
CF1 R-PRF-01
Page 2 of 10
Calculation Description: Title 24 Analysis
HERS FEATURE SUMMARY
Input File Name: 050 - 81743 ANDALUSIA.ribd16x
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below
Building -level Verifications:
• --None--
Cooling System Verifications:
• -- None --
-VAC Distribution System Verifications:
• -- None --
Domestic Hot Water System Verifications:
• -- None --
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ftZ)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
McCLUSKEY RESIDENCE
3608
1
3
2
0
1
ZONE INFORMATION
01
02
03
04
05
I 06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ftZ)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
(E) 3547
Conditioned
(E) AC-1
3547
10
DHW Sys 1
n/a
(N) 61
Conditioned
(E) AC-1
61
10
DHW Sys 1
n/a
Registration Number: Registration Date(Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-06-17 16:34:09
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: McCLUSKEY RESIDENCE Calculation Date/Time: 16:33, Mon, Jun 17, 2019
CF1 R-PRF-01
Page 3 of 10
Calculation Description: Title 24 Analysis
Input File Name: 050 - 81743 ANDALUSIA.ribdl6x
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
10
11
Name
Zone
Construction
Azimuth
Orientation
Gross Area
(ft2)
Window & Door
Area (ft2)
Tilt
(deg)
Wall
Exception
Status
Verified
Existing
Condition
NE - 213
(E) 3547
Def Wall '92 to Present
45
Front
213
54.5
90
n/a
Existing
No
SE- 880
(E) 3547
Def Wall '92 to Present
135
Left
880
114.5
90
n/a
Existing
No
SW - 715
(E) 3547
Def Wall '92 to Present
225
Back
715
204
90
n/a
Existing
No
NW- 715
(E) 3547
Def Wall '92 to Present
315
Right
715
168
90
n/a
Existing
No
TO ADD
(E) 3547» (N) 61
Def Wall '92 to Presentl
35
0
n/a
Existing
No
3547
(E) 3547
Def Roof'78 to Present
3547
n/a
Existing
No
NE - 147
(N) 61
R-21 Wall
45
Front
147
49
90
none
New
n/a
SE-45
(N) 61
R-21 Wall
135
Left
45
4
90
none
New
n/a
30
(N) 61
R-38 Roof Attic
30
n/a
New
n/a
31
(N) 61
R-38 Roof Attic
31
n/a
New
n/a
ATTIC
01
02
03
04
05
06
07
08
09
10
Name
Construction
Type
Roof Rise
Roof
Reflectance
Roof
Emittance
Radiant
Barrier
Cool
Roof
Status
Verified Existing
Condition
Attic (E) 3547
Attic Roof(E) 3547
Ventilated
4
0.1
0.85
No
No
Existing
No
Attic (N) 61
Attic Roof(N) 61
Ventilated
4
0.1
0.85
No
No
New
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-06-17 16:34:09
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: McCLUSKEY RESIDENCE Calculation Date/Time: 16:33, Mon, Jun 17, 2019
CF1 R-PRF-01
Page 4 of 10
Calculation Description: Title 24 Analysis
Input File Name: 050 - 81743 ANDALUSIA.ribd16x
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multiplier
Area (ft2)
LI-factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
4650
NE - 213 (Front-45)
4.5
5.0
1
22.5
0.71
0.73
Insect Screen (default)
Existing
No
1620
SE- 880 (Left-135)
1.5
2.0
1
3.0
0.71
0.73
Insect Screen (default)
Existing
No
5050
SE- 880 (Left-135)
5.0
5.0
1
25.0
0.71
0.73
Insect Screen (default)
Existing
No
3080
SE- 880 (Left-135)
3.0
8.0
1
24.0
0.71
0.73
Insect Screen (default)
Existing
No
3050
SE- 880 (Left-135)
2.0
5.0
1.5
15.0
0.71
0.73
Insect Screen (default)
Existing
No
5650
SE- 880 (Left-135)
5.5
5.0
1
27.5
0.71
0.73
Insect Screen (default)
Existing
No
2050
SE- 880 (Left-135)
2.0
5.0
1
10.0
0.71
0.73
Insect Screen (default)
Existing
No
20502
SE- 880 (Left-135)
2.0
5.0
1
10.0
0.71
0.73
Insect Screen (default)
Existing
No
20503
SW - 715 (Back-225)
2.0
5.0
1
10.0
0.71
0.73
Insect Screen (default)
Existing
No
20504
SW - 715 (Back-225)
2.0
5.0
1
10.0
0.71
0.73
Insect Screen (default)
Existing
No
8050
SW - 715 (Back-225)
8.0
5.0
1
40.0
0.71
0.73
Insect Screen (default)
Existing
No
16080
SW - 715 (Back-225)
16.0
8.0
0.375
48.0
0.71
0.73
Insect Screen (default)
Existing
No
12080
SW - 715 (Back-225)
12.0
8.0
1
96.0
0.71
0.73
Insect Screen (default)
Existing
No
6080
NW- 715 (Right-315)
6.0
8.0
1
48.0
0.71
0.73
Insect Screen (default)
Existing
No
20505
NW- 715 (Right-315)
2.0
5.0
1
10.0
0.71
0.73
Insect Screen (default)
Existing
No
20506
NW- 715 (Right-315)
2.0
5.0
1
10.0
0.71
0.73
Insect Screen (default)
Existing
No
30502
NW- 715 (Right-315)
3.0
5.0
1
15.0
0.71
0.73
Insect Screen (default)
Existing
No
30503
NW- 715 (Right-315)
3.0
5.0
1
15.0
0.71
0.73
Insect Screen (default)
Existing
No
30504
NW- 715 (Right-315)
3.0
5.0
1
15.0
0.71
0.73
Insect Screen (default)
Existing
No
20507
NW- 715 (Right-315)
2.0
5.0
1
10.0
0.71
0.73
Insect Screen (default)
Existing
No
1650
NW- 715 (Right-315)
1.5
5.0
1
7.5
0.71
0.73
Insect Screen (default)
Existing
No
16502
NW- 715 (Right-315)
1.5
5.0
1
7.5
0.71
0.73
Insect Screen (default)
Existing
No
16503
NW- 715 (Right-315)
1.5
5.0
1
7.5
0.71
0.73
Insect Screen (default)
Existing
No
16504
NW- 715 (Right-315)
1.5
5.0
1
7.5
0.71
0.73
Insect Screen (default)
Existing
No
16505
NW- 715 (Right-315)
1.5
5.0
1
T5
0.71
0.73
Insect Screen (default)
Existing
No
16506
NW- 715 (Right-315)
1.5
5.0
1
7.5
0.71
0.73
Insect Screen (default)
Existing
No
7070
NE - 147 (Front-45)
7.0
7.0
1
49.0
0.51
0.24
Insect Screen (default)
New
n/a
2020
SE - 45 (Left-135)
2.0
2.0
1
4.0
0.51
0.24
Insect Screen (default)
New
n/a
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-06-17 16:34:09
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: McCLUSKEY RESIDENCE Calculation Date/Time: 16:33, Mon, Jun 17, 2019
CF1 R-PRF-01
Page 5 of 10
Calculation Description: Title 24 Analysis
Input File Name: 050 - 81743 ANDALUSIA.ribd 1 6x.
OPAQUE DOORS
01
02
03
04
05
06
Name
Side of Building
Area (ft2)
U-factor
Status
Verified Existing Condition
4080
NE - 213
32.0
0.50
Existing
No
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149
HERS Provider:
Report Generated at: 2019-06-17 16:34:09
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: McCLUSKEY RESIDENCE Calculation Date/Time: 16:33, Mon, Jun 17, 2019
CF1 R-PRF-01
Page 6 of 10
Calculation Description: Title 24 Analysis
Input File Name: 050 - 81743 ANDALUSIA.ribd16x
OVERHANGS AND FINS
01
02
03
04 05 J
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right
Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
4650
2
0.1
2
2
0
0
0
0
0
0
0
0
0
1620
2
0.1
2
2
0
0
0
0
0
0
0
0
0
5050
2
0.1
2
2
0
0
0
0
0
0
0
0
0
3080
2
0.1
2
2
0
0
0
0
0
0
0
0
0
3050
2
0.1
2
2
0
0
0
0
0
0
0
0
0
5650
15
0.1
15
15
I 0
0
0
0
0
0
0
0
0
2050
2
0.1
2
2
0
0
0
0
0
0
0
0
0
20502
2
0.1
2
2
0
0
0
0
0
0
0
0
0
20503
2
0.1
2
2
0
0
0
0
0
0
0
0
0
20504
2
0.1
2
2
0
0
0
0
0
0
0
0
0
8050
2
0.1
2
2
0
0
0
0
0
0
0
0
0
16080
15
0.1
15
15
0
0
0
0
0
0
0
0
0
12080
8
0.1
8
8
0
0
0
0
0
0
0
0
0
6080
15
0.1
15
15
0
0
0
0
0
0
0
0
0
20505
2
0.1
2
2
0
0
0
0
0
0
0
0
0
20506
2
0.1
2
2
0
0
0
0
0
0
0
0
0
30502
2
0.1
2
2
0
0
0
0
0
0
0
0
0
30503
2
0.1
2
2
0
0
0
0
0
0
0
0
0
30504
2
0.1
2
2
0
0
0
0
0
0
0
0
0
20507
2
0.1
2
2
0
0
0
0
0
0
0
0
0
1650
2
0.1
2
2
0
0
0
0
0
0
0
0
0
16502
2
0.1
2
2
0
0
0
0
0
0
0
0
0
16503
2
0.1
2
2
0
0
0
0
0
0
0
0
0
16504
2
0.1
2
2
0
0
0
0
0
0
0
0
0
16505
2
0.1
2
2
0
0
0
0
0
0
0
0
0
16506
2
0.1
2
2
0
0
0
0
0
0
0
0
0
7070
6
0.1
6
6
0 0
0
0
0
0
0
0
0
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-06-17 16:34:09
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: McCLUSKEY RESIDENCE Calculation Date/Time: 16:33, Mon, Jun 17, 2019
CF1 R-PRF-01
Page 7 of 10
Calculation Description: Title 24 Analysis
Input File Name: 050 - 81743 ANDALUSIA. ribd 1 6x
2020 1 2 1 0.1 1 2 1 2 1 0 1 0 1 0 1 0 0 1 0 1 0 0 1 0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-factor
Assembly Layers
• Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
• Roof Deck: Wood Siding/sheathing/decking
Attic Roof(E) 3547
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
• Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
• Cavity/Frame: R-9.1 /2x4
Def Roof '78 to Present
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 19
0.049
Over Ceiling Joists: R-9.9 insul.
• Inside Finish: Gypsum Board
• Cavity/Frame: R-13/2x4
Def Wall '92 to Present
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.101
Exterior Finish: 3 Coat Stucco
• Inside Finish: Gypsum Board
• Cavity / Frame: R-13 / 2x4
Def Wall '92 to Presentl
Interior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.092
Other Side Finish: Gypsum Board
• Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roof(N) 61
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
R-21 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.069
Exterior Finish: 3 Coat Stucco
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 38
0.025
Over Ceiling Joists: R-28.9 insul.
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ft2)
Perimeter
(ft)
Edge Insul. R-value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
35472
(E) 3547
3547
0.1
None
0.8
No
Existing
No
61
(N) 61
61
0.1
None
0
No
New
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Not Required
Not Required
Not Required
n/a
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-06-17 16:34:09
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: McCLUSKEY RESIDENCE Calculation Date/Time: 16:33, Mon, Jun 17, 2019
CF1 R-PRF-01
Page 8 of 10
Calculation Description: Title 24 Analysis
Input File Name: 050 - 81743 ANDALUSIA.ribd16x
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
(%)
Status
Verified Existing
Condition
DHW Sys 1
DHW
Standard
DHW Heater 1
1
0
Existing
No
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Input Rating /
Tank
Standby
Heater
Tank
Uniform Energy
Pilot /
Insulation
Loss /
First Hour
Tank Location
Element
Number
Volume
Factor / Energy
Thermal
R-value
Recovery
Rating /
NEEA Heat Pump
or Ambient
Name
Type
Tank Type
of Units
(gal)
Factor / Efficiency
Efficiency
(Int/Ext)
Eff
Flow Rate
Brand / Model
Condition
DHW Heater 1
Gas
Small Storage
1
50
0.525 EF
<= 75 kBtu/hr
0
n/a
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
Distribution
Verified Existing
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Name
Status
Condition
(E) AC-1
Other Heating and Cooling
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution
System 1
Existing
No
System
I
I
I
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R-value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
(Ventilated and
Existing (not
6.0
Attic
Attic
None
Existing
No
n/a
System 1
Unventilated)
specified)
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
0
0.25
Default
0
Not Required
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-06-17 16:34:09
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: McCLUSKEY RESIDENCE Calculation Date/Time: 16:33, Mon, Jun 17, 2019
CF1 R-PRF-01
Page 9 of 10
Calculation Description: Title 24 Analysis
Input File Name: 050 - 81743 ANDALUSIA.ribd16x
PROJECT NOTES
-- ALL EXISTING AND PROPOSED INPUT DATA USED IN THIS REPORT WAS PROVIDED BY THE PLANS PREPARER. -- LOAD CALCULATIONS AND AC SIZING EQUIPMENT SHALL BE
VERIFIED BY THE AC CONTRACTIOR PRIOR TO PLACEMENT OF ITS ORDER. -- AC EQUIPMENT'S EFFICENCY SHALL BE EQUAL (OR BETTER) THAN REQUIRED BY THIS REPORT. --
ANY ALTERATION OR DEVIATION FROM THIS REPORT WILL BE GENERAL CONTRACTOR'S RESPONSABILITY.
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-06-17 16:34:09
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: McCLUSKEY RESIDENCE Calculation Date/Time: 16:30, Mon, Jun 17, 2019
CF1 R-PRF-01
Page 10 of 10
Calculation Description: Title 24 Analysis
Input File Name: 050 - 81743 ANDALUSIA.ribd16x
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature
Armando Chavez
Signature Date:
Company:
6/17/2019
Address:
CEA/HERS Certification Identification (If applicable):
44890 SEELEY
city/Statfg:QUINTA, CA 92253
Phone: 760 278.1840
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit applicatio
Responsible De Ver Name:
RUB
Responsible Designer Signature:
Company:
Date Signed:
GLS ARCHITECTURE GROUP INC.
9-16-19
Address:
License:
74991 JONI DR #9
N/A
City/Statel7_ io:
PALM DESERT, CA 92260
Phone:
760 340.3528
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-07312017-695 Report Generated at: 2019-06-17 16:30:57
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
McCLUSKEY RESIDENCE'S addition
Project Address
81743 ANDALUSIA LA QUINTA
Building Type m Single Family ❑ Addition Alone
❑ Multi Family 10 Existing+ Addition/Alteration
Date
611712019
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
3,608
Addition
61
# of Units
1
INSULATION
Construction Ty2e
Cavity
Area
(ft) Special Features
Status
Slab Unheated Slab -on -Grade - no insulation
3,547 Perim = 0'
Existing
Roof Wood Framed Attic R 19
Wall Wood Framed R 13
Door Opaque Door - no insulation
3,547
2,017
32
Existing
Existing
Existing
Wall Wood Framed R 21
139
New
Roof Wood Framed Attic R 38
61
New
Slab Unheated Slab -on -Grade -
no insulation
61 Perim = 0'
New
FENESTRATION I Total Area: 562 Glazing Percentage: 15.6% New/Altered Averse U-Factor:
Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades
0.51
Status
Front (NE) 22.5 0.710
0.73 2.0
none Bug Screen
Existing
Left (SE) 87.0 0.710
0.73 2.0
none Bug Screen
Existing
Left (SE) 27.5 0.710
0.73 15.0
none Bug Screen
Existing
Rear (SW) 60.0 0.710
0.73 2.0
none Bug Screen
Existing
Rear (SW) 48.0 0.710
0.73 15.0
none Bug Screen
Existing
Rear (SW) 96.0 0.710
0.73 8.0
none Bug Screen
Existing
Right (NW) 48.0 0.710
0.73 15.0
none Bug Screen
Existing
Right (NW) 120.0 0.710
0.73 2.0
none Bug Screen
Existing
Front (NE) 49.0 0.510
0.24 6.0
none Bug Screen
New
Left (SE) 4.0 0.510
0.24 2.0
none Bug Screen
New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling
Min. Eff Thermostat
Status
1 Central Furnace 78% AFUE
HVAC DISTRIBUTION
Location Heating
Packaged Air Condition 13.0 SEER Setback
Duct
Cooling Duct Location R-Value
Existing
Status
(E) AC- Ducted Ducted Attic 6.0
WATER HEATING
Qty. Type Gallons Min. Eff Distribution
Existing
Status
EnengyPro 7.1 by Ener vSoft User Number: 20648
ID: 19 - GLS / 070 - 048
Page 13 of 17
2016 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. *Exceptions may apply
un inal =ZUlfi
Building Envelope Measures:
§ 110.6(a)l:
Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ftz or less when tested per
NFRC-400 or ASTM E283 or AAMAIWDMA/CSA 101/I.S.2/A440-2011.'
§ 110.6(a)5:
Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a).
§ 110.6(b):
Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES
110.6-A and 110.6-13 for compliance and must be caulked and/or weatherstri ed.'
§ 110.7:
Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
asketed, or weather stri ed.
§ 110.8(a):
Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material.
§ 110.8(g):
Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g).
§ 110.8(i):
Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing
material must meet the requirements of § 11 0.8i when the installation of a cool roof is specified on the CF1 R.
§ 110.80):
Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043.
Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
§ 150.0(a):
insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited
to placing insulation either above or below the roof deck or on top of a drywall ceilin .'
§ 150.0(b):
Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value.
Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-factor of 0.074 or
§ 150.0(c):
less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a
wood framed assemblv.'
§ 150.0(d):
Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.'
§ 150.0(f)
Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light
deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 11 0.8.
§ 150.0(g)1:
Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This
requirement also applies to controlled ventilation crawls ace for buildings com I in with the exception to § 150.0(d).
§ 150.0(g)2:
Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class 11 vapor retarder must be installed on the conditioned space side of all
insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation.
§ 150.0 (q):
Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.'
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 150.0(e)lA:
Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)1 B:
Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area
and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.`
§ 150.0(e)1 C:
Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.'
§ 150.0(e)2:
Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of
the building, are prohibited.
Space Conditioning, Water Heating, and Plumbing System Measures:
§ 110.0-§ 110.3:
Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
appliances must be certified by the manufacturer to the Energy Commission.'
§ 110.2(a):
HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.'
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§ 110.2(b):
must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for
compression heating is higher than the cut-off temperature for supplementary heating!
§ 110.2(c):
Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat.'
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
§ 110.3(c)5:
meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of §
110.3(c)5.
§ 110.3(c)7:
Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs
or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed.
§ 110.5.
Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli-
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt); and pool and spa heaters.'
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment
E150§ 0(h)1:
Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA
Manual J using design conditions specified in 5_150.0(h)2.
3 2016 Low -Rise Residential Mandatory Measures Summary
Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any
§ 150.0(h)3A:
d er vent.
§ 150.0(h)3B:
Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by
manufacturer's instructions.
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
§ 150.00)1.
R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must
be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a
§ 150.00)2A:
nominal diameter of 314 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter;
piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to
kitchen fixtures!
Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a waterproof
§ 150.OQ)2B:
and non -crushable casing or sleeve!
Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution
§ 150.00)2C:
piping for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.`
§ 150.00)3:
Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by
§ 150.00)3A:
aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can
cause degradation of the material.
Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a
§ 150.00)3B:
Class I or Class II vapor retarder.
Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a
120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside
§ 150.0(n)t
termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr.
§ 150.0(n)2:
Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification
§ 150.0(n)3:
Corporation (SRCC) or by a listing agency that is approved by the Executive Director
Ducts and Fans Measures:
Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a
§ 110.8(d)3:
contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement.
CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC
§§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSIISMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or
a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing
§ 150.0(m)1
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than Y< inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain
ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts'
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
§ 150.0(m)2:
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such tape is used in combination with mastic and draw bands.
§ 150.0(m)3:
Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
mastics sealants and other requirements specified for duct construction.
§ 150.0(m)7:
Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
automatic dampers.
§ 150.0(m)8
Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually operated dampers in all openings to the outside, except combustion inlet and outlet air n enin s and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
§ 150.0(m)9:
wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation.
§ 150.0(m)10:
Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)11:
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 150.0(m)11 and Reference Residential Appendix RA3.
Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,
pressure drop, and labeling requirements of § 150.0(m)12.
2016 Low -Rise Residential Mandatory Measures Summary
Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable
space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the
§ 150.0(m)13:
supply plenum. The space conditioning system must also demonstrate airflow Z 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy:5 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central
forced air systems.'
Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor
§150.0(o):
continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of
providing whole -building ventilation.
§ 150.0(o)1A:
_
Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.7.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
§ 110.4(a):
that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heatin .'
§ 110.4(b)1:
Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated
suction and return lines, or built-in or built-up connections to allow for future solar heatin .
§ 110.4(b)2:
Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b)3:
Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
will allow all pumps to be set or programmed to run only during off-peak electric demand periods.
§ 110.5:
Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
150.0
§ (p)
Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
rate, piping. filters, and valves.'
Lighting Measures:
§ 110.9:
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
of § 110.9.'
§ 110.9(e):
JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must
be certified to the Energy Commission according to Reference Joint Appendix JA8.
§ 150.0(k)1A:
Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or
§ 150.0(k)1 B:
other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fan speed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)1 C:
labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C. A JA8-2016-E light source rated for
elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings.
§ 150.0(k)1 D:
Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than
20 kHz.
Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no
§ 150.0(k)1 E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled
by vacancy sensors.
§ 150.0(k)1 F
Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
must meet the applicable requirements of § 150.0(k).'
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply
§ 150.0(k)1 G:
with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix
JA8.'
§ 150.0(k)1 H:
Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E."
§ 150.0(k)2A:
Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B:
Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.'
§ 150.0(k)2C:
Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually
switched ON and OFF.
§ 150.0(k)2D:
Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with
150.0(k).
§ 150.0(k)2F:
Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it:
§ 150.0(k)2G:
functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of §
130.5 ; and meets all other requirements in § 150.0(k)2.
_
Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the
§ 150.0(k)2H:
following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of §
130.5 ; and all other requirements in § 150.0(k)2.
§ 150.0(k)21:
Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
Z 2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(k)2J:
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
be controlled by a vacancy sensor.
§ 150.0(k)2K:
Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with
Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways!
§ 150.0(k)2L:
Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A:
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item
§ 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or
EMCS.
Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies,
§ 150.0(k)3B:
and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with
either § 150.0 k 3A or with the ap2licable re uirements in §§ 110.9, 130.0. 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)3C:
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by
§ 150.0(k)3B or § 150.0(�3D must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)3D:
Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more
vehicles per site must comply with the applicable requirements in §§ 110.9,130.0, 130.2 130.4, 140.7, and 141.0.
§ 150.0(k)4:
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 wafts of
ower as determined according to § 130.0(c).
§ 150.0(k)5:
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A:
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be high efficacy luminaires and controlled by an occupant sensor.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must:
§ 150.0(k)6B:
i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1:
application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the
requirements of § 110.1 0b through § 110.10(e).
§ 110.10(a)2:
Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d).
Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local
jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet
each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas
§ 110.10(b)1
greater than 10,000 square feet.
For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250
square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang
of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less
than 15 percent of the total roof area of the building excluding any skylight area.'
§ 110.10(b)2:
Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.*
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)3B:
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone, measured in the vertical lane.'
§ 110.10(b)4:
Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof
dead load and roof live load must be clearly indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for
§ 110.10(c):
routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system.
§ 110.10(d):
Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
110.10(c) must be provided to the occupant.
§ 110.10(e)1:
Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2:
breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or
main circuit location; and permanently marked as "For Future Solar Electric".
APPENDIX It: ARCHITECTURAL / LANDSCAPING IMPROVEMENT/HOUSE AND GARAGE PAINTING
REQUEST AND AGREEME14T
Date of Request: ^ {11I I Lot Tract N
s Owner/Applicant: SI (-(— kc Cl-Ltg I
Andalusia at Coral Mountain Address: 0 4 C it5
aA,-75
Local Telephone: PV ��~`� Other
( Telephone: _
Architect(s), if applicable: 77,�->A�ro
Architect(s)'s Address: e
Architect(s)'s Telephone Number:
• Contractor(s), if applicable:It�nP
Contractor(s)'s Address:
UL !' 17 2019
Contractor'(s)'s Telephone:
MY OF LA QUINTA
DESIG 44 AND 0EVELO P _ME NT DEPARTMENT
(Attach additional sheets with name(s) of Contractors/Subcontractors, if necessary)
• Description of Improvement (Please provide a complete narrative description of the prop(s modification and include
drawings as appropriate) f
Attachments sets):
ull construction drawings a Specifications/Dimensions
C! Site Plan ❑ Drainage Plan
❑ Landscape Plans ❑ Elevations
D Other (describe/list or attach additional pages as required); .
Starting Date #6 W__ Estimated Completion Date _ _ —3—hvu
This Architectural / Landscape Improvement Request shall be accompanied by:
A non-refundable fee of $406 as a processing and review fee to check the plans for conformance with the Design Review
Guidelines. No fee for Garage & House Painting/Staining Applications The check for this fee shall be paid to the order of Andalusia at
Coral Mountain Associa io . See appendix V for other fees.
A security deposit to be drawn against by Master Association for any and all direct costs t is ion including, but
not limited to, the following: (1) legal expense , (2) consulting fees, 4) recordation costs; (5) nonrefundable
administrative costs (application fee); (6) os s e a1r a to the common area and/or streets maintained by the Master
Association caused by the construction of ural Improvement; (7) any other costs directly r&Mted to and/or necessary for the
supervision of the Architectur ve a well as to bring the costs necessary for the Master Association to bring the
Architectural tmprov no compliance with the Master Declaration and/or these Guidelines; and (8) payment for any Enforcement
Assessmen in accordance with the Master Association's Enforcement Procedure. The check for this fee shall be paid to the
order ndalusia At Coral Mountain Association. This security deposit, minus Master Association's direct costs, shall be returned upon
order
spt of the Notice of Completion from Owner and final sign -off by Design Review Committee.
All copies of plans and specifications, as enumerated in the Application Procedure, Section 4, (page 30)
THE OWNER(S) UNDERSTANDS AND AGREES TO THE FOLLOWING:
1. By submission of this application, I/we have followed the Architectural / Landscape Request Procedure as specified in the
Master Association's Architectural / Landscape Guidelines, beginning on page 29, including the attachment of three sets of any
applicable plans, specifications, drawings, manufacturer's brochures, city building permits, signed cons!ruction regulations, and/or other
descriptions as may be required by the Checklists, beginning on page 32
-37-
Master Design Guidelines 1/1/2012 (Amended 4-25-13)
2 The architectural modifications will be made in strict compliance with the approved plans and specifications submitted with
lhrs applrCatior. Should any changes be required at any time during the project, those chances must be approved by the Design
Review Committee Architectural & Landscaping Approval Request Form and Agreement and noted on this application
Owner shall hold the h'ias,er F,ssociaticr harmless from all liabiilty related to any damage to existing residences,
improvements thereon, any common area property andlor golf coCrse wherever located with:: the Andalusia at Coral mountain
subdivision, resvftinc frorn tr,e installationlcanstruction of this Improvement cr modification. Applicant shtlt advise hilaster Association
office pfemptly upon completion of the work.
4. Any application shall be deemed incomplete; and the Design Review Committer shall disapprove, any and all plans and/or
specifications submitted to it for approval if the Owner fails to deliver the required fees and security deposit referenced herein.
5. Owner shall comply with the Design Guidelines of.the Andalusia at Coral Mountain Master Association, and furnish copies of
these provisions to the contractor(s) engaged by Ovmer for the improvement. Applicant further understands that it is Owners
responsibility to ensure that his/her contractor(s) also Complies with these provisions.
6. Owner shall secure proper building permits, if required by the local governmental entity. Applicant understands that the City
of La Quinta may not approve any plans which have not yet been approved by the Master Association's Design Review Committee.
7- Owner shall pay the fees and deposits, as set forth in Section 5.3 of the Design Guidelines to process this Architectural
Request Form, the terms of which are incorporated herein by this reference.
5. Applicant agrees to complete the Properties within ninety (90) days of the Properties Approval date; unless otherwise stated.
"Properties Approval Da,e" is defined as the date of the letter granting Applicant approval to proceed vrith the Properties "Completion"
is defined as the date when the City of La Quinta has conducted its €inal inspection and approved the irnprovement(s), or, if no building
permit is required, the date the Design Review Committee gives final approval.
S. Owner(s) agrees that helshe/they will be solely responsible for the maintenance of the improvement
Signatures: pvdrl Date: i 1 sa
Owner. Date.
For house painting and garage refurbishing please provide the information below::
The attached request has been reviewed by the Design Review Committee and its action is:
Xpproved as Subm�d_ —1 Approved as mended D Rejected ❑ R 'ected, Pending F her Information 0 Refer to
attached comments f�jG..� 'T
Date. Signatur .
:FP, acia ron n Review Committee
Final Inspection: D Approved as submitted
Date:
Signature:
D Disapproved (refer to the attached comments)
For the Association Design Review Committee
-38-
Master Design Guidelines 1/1/2012 (Amended 4-25-13)