Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BSOL2019-0028
78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type/Subtype: Application Number: Property Address: APN: Application Description Property Zoning: Application Valuation: T4ht 4 s(P Qu4& DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT SOLAR/RESIDENTIAL LESS THAN 10KW BSOL2019-0028 81392 JOSHUA TREE CT 764790055 HANSEN / 5.12kW (DC) PV SYSTEM $18,000.00 Applicant: JAMES PETERSEN INDUSTRIES INC DBA SOLAR 39300 CIVIC CENTER DR STE 300 FREMONT, CA 94538 oQa�OCT 0 i 2019 CITY OF IU", OulI IA DESIGN & DEVELO,PIy)ENT DEF',"RTiiIENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C46. C20. C36_ C10 Licen No.: 1050201 Date: to - I^ ( Contracts OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Da Owner: CONSTRUCTION LENDING AGENCY hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Na Lender's Add VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/1/2019 Owner: PAULA HANSEN , 92253 Contractor: JAMES PETERSEN INDUSTRIES INC DBA SOLAR 39300 CIVIC CENTER DR STE 300 FREMONT, CA 94538 (510)371-6500 Llc. No.: 1050201 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 700 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: DEPARTMENT OF INDUSTRIAL RELATIONS __ Policy Number: 2371 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, fthould become subject to the workers' compensation provisions of Section 0 of the Labor Code, I shall forthwith comply with those provisions. Date: 10 ^ 1 — 11 Apgli[a v WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance ofthis permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above i rmation is correct. I agree to comply with all city and county ordinances and state s r lating to building construction, and hereby authorize representatives of this ci to ent6r upon the above - mentioned property for inspection purposes. Date: I�' (� Signature (Applicant or Agen): Date: 10/1/2019 Application Number: BSOL2019-0028 Property Address: 81392 JOSHUA TREE CT APN: 764790055 Application Description: HANSEN / 5.12kW (DC) PV SYSTEM Property Zoning: Application Valuation: $18,000.00 Applicant: JAMES PETERSEN INDUSTRIES INC DBA SOLAR 39300 CIVIC CENTER DR STE 300 FREMONT, CA 94538 Owner: PAULA HANSEN , 92253 Contractor: JAMES PETERSEN INDUSTRIES INC DBA SOLAR 39300 CIVIC CENTER DR STE 300 FREMONT, CA 94538 (510)371-6500 Llc. No.: 1050201 Detail: 5.12kW SOLAR ARRAY (16 - 320W SIFFAB PANELS+SOLAREDGE P 320 OPTIMIZERS W/ SE5000H-US-AFCI INVERTER[319SF} OPTIMIZER) TO REPLACE EXISTING 4.26kW (DC) SYSTEM WITH TILE RAISE AND REPLACEMENT OF ROOFING PAPER AND RESET UNDER SOLAR PANEL AREA ONLY. PER 2016 CALIFORNIA BUILDING AND ELECTRICAL CODES. DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT CITY AMOUNT PV SYSTEM LESS THAN 10KW 101-0000-42403 0 $26.83 DESCRIPTION ACCOUNT CITY AMOUNT PV SYSTEM LESS THAN 10KW PC 101-0000-42600 0 $26.83 Total Paid for ELECTRICAL 2019: $53.66 DESCRIPTION ACCOUNT CITY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $101.97 Total Paid for PERMIT ISSUANCE: $101.97 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 Project Address: (5, 3 9 z 7 b Shv )�- T APN #: ApplicantName: Address:Cr]TRb�7�Q— City, ST, Zip: Telephone: 7 fo0 • 4 U e- Z I o Email: n GCS-A(5;a Qb 7 Contractor Name:?cWte, "J Address: ( 8 z'o coo,,,riw �,ea City, St, Zip 12�v�S 8 - Telephone:760 - qog - Z I Email: 1 L E7gWev PET62 State Lic: qb&(17 City Bus Lic: 10 S02a1 Arch/Eng Name: Address: City, St, Zip Telephone: mail: to Lic: City Bus Lic: arty Owner's Name- �p I A W 5 � 3: o\3SZ •J c-AOL. I R.e-c G-- ,Zip PERMIT PLAN LOCATION: Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech ICAM U ow 5 s Sr, ► Z- zoJ 1 C� sn p u Valuation of Project $ `� New SFD Construction: Conditioned Space Garage Patio/Porch Fire Sprinklers Construction Type: Grading: Bedrooms: I Stories: SF SF SF SF Occupancy: # Units: New Commercial / Tenant Improvements: Total Building SF Construction Type: Occupancy: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 not modify any of the terms or conditions of this No Modification warranty, nor extend the term. The terms, conditions, and limitations of this warranty may not be altered or modified. How to Contact Us Should you have any questions regarding your solar system or this warranty, please contact our Customer Service Department at 800,564.0362 to speak to a representative. You may also email us at customercare@petersendean.com or visit our website at www.petersendean.com. What You Must Do to Make a Claim. You must notify us within ten (10) days of discovering a claim. You must give us an opportunity to investigate the claim before the conditions giving rise to your claim are changed. If you do not give us timely notice of a claim, or if you attempt to make, or have others make any repairs before giving us notice of the claim and an opportunity to investigate the condition, we may have no obligation under this warranty. In the event the condition requires emergency action, you must report the emergency to us at (800) 564-0362 and provide us an opportunity to inspect the condition before any repairs are made. LIMITATION OF REMEDIES AND LIABILITIES OUR SOLE OBLIGATION, AND YOUR EXCLUSIVE REMEDY, UNDER THIS WARRANTY 1S LIMITED TO THE TERMS OF THIS AGREEMENT, IN NO EVENT WILL S4A BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, GENERAL, OR CONSEQUENTIAL DAMAGES ALLEGEDLY ARISING FROM OR CAUSED BY S4A'S ACTS OR OMISSIONS UNDER ANY LEGAL BASIS OR THEORY, INCLUDING CONTRACT, TORT, OR VIOLATION OF STATUTE. IN NO EVENT SHALL S4A,S TOTAL LIABILITY TO YOU FOR ALL DAMAGES, LOSSES, AND CAUSES OF ACTION (WHETHER IN CONTRACT OR TORT, INCLUDING, BUT NOT LIMITED TO NEGLIGENCE) EXCEED THE AMOUNT PAID TO S4A FOR THE SOLAR SYSTEM. SOME STATES DO NOT ALLOW EXCLUSIONS OR LIMITATIONS ON INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSIONS MAY NOT APPLY TO YOU. ARBITRATION OF DISPUTES ANY DISPUTE ARISING OUT OF OR RELATING TO THE CONSTRUCTION, PERFORMANCE OR NON-PERFORMANCE OF ANY ASPECT OF THIS WARRANTY OR THE WORK PERFORMED BY US, INCLUDING WITHOUT LIMITATION ANY CLASS ACTION OR ANY CLAIM ARISING FROM OUR INSTALLATION OF THE SOLAR SYSTEM COVERED BY THIS WARRANTY, SHALL BE RESOLVED BY BINDING ARBITRATION CONDUCTED IN THE STATE IN WHICH THE RESPECTIVE PROJECT IS LOCATED, AND IN ACCORDANCE WITH THE CODE OF PROCEDURE AND FEE SCHEDULE OF THE NATIONAL ARBITRATION FORUM. A COPY OF THE CODE OF PROCEDURE AND THE FEE SCHEDULE CAN BE OBTAINED AT WWW.ADRF0R_QM,C0M. ANY AND ALL COSTS AND FEES ASSOCIATED WITH ARBITRATION ARE TO BE SPLIT EVENLY AMONGST S4A AND THE CUSTOMER. JUDGMENT UPON THE AWARD RENDERED BY ANY SUCH ARBITRATOR IS FINAL AND NON -APPEALABLE, AND MAY BE ENTERED IN ANY COURT HAVING JURISDICTION THEREOF. THIS ARBITRATION PROVISION, AND ALL ARBITRATION PROCEEDINGS, HEARINGS, AWARDS, AND ORDERS ARE TO BE GOVERNED BY THE FEDERAL ARBITRATION ACT, 9 U.S.C. §§ 1-16. Please note that the manufacturer's warranty will serve as the primary warranty for the product(s) for ,your solar system installation. In certain circumstances, S4A may provide any necessary labor for obligations associated with the manufacturer's warranty. Should the manufacturer experience dissolution, insolvency, business failure, reorganization, or bankruptcy, S4A will not assume the manufacturer's warranty obligations. Paula C Hansen (Apr 22, 2019) 092017 SLAmM Monocrystalline lk .IusT 1('0TIER 1 • BAA 252 �' 1 }= IN HANICAHLEL ARRA�liY i iIME i . i $$$ i HIG#! 320 Wp 60 Cell Monocrystalline PV Module (Available Early 2019) C E.t ❑oiEc �i �I �Vf �R '•«��rk �� r N� M Fraunhofer ISE ENSURES MAXIMUM EFFICIENCY 60 of the highest efficiency, premium quality monocrystalline cells result in a maximum power rating of 320Wp. ADVANCED PERFORMANCE WARRANTY 30-year linear power performance guarantee ENHANCED PRODUCT WARRANTY 25-year product workmanship warranty* :HE BUILT BY INDUSTRY EXPERTS With over 35 years of industry experience, Silfab's technical team are pioneers in PV technology and are dedicated to an innovative approach that provides superior manufacturing. processes including: infra -red cell sorting, glass washing, automated soldering and meticulous cell alignment. POSITIVE TOLERANCE (-0/+5W) All positive module sorting ensures maximum performance :c LOWEST DEFECT RATE* Total automation ensures strict quality control during each step of the process at our certified ISO manufacturing facility. *82.56 ppm as per December 2017 := LIGHT AND DURABLE Engineered to accommodate low load bearing structures, while boasting up to 5400 Pa snow load capabilities. Light- weight frame is exclusively designed with wide-ranging racking compatibility and durability In mind. PID RESISTANT ,PID Resistant due to advanced cell technology and material selection. In accordance to IEC 62804-1 AVAILABLE WITH Black Frame and Backsheet *12 year- extendable cased on registration at wwwsilfabsolar com Test Conditions STC NOCT Module Power (Pm_ax) W'p 242 Maximum power voltage (Vpmax) _ V _ 30.3 Maximum power current (I max) A 9.5 8.0 Open circuit voltage (Voc) V 40.45 37.42 Short circuit_ current (Isc) illift 8.17 Module efficiency _A % 19.6 _ 18.5 Maximum system voltage (VDC) V 1000 Series fuse rating A _ _ _ 20 _ Power Tolerance Wo -0/+5 Measurement conditions: STC 1000 W/m2 • AM 1.5 • Temperature 25 °C • NOCT 800 W/m2 • AM 1.5 • Measurement uncertainty < 3% - Sun simulator calibration reference modules from Fraunhofer Institute. Electrical characteristics may vary by±5%and power by-0/+SW. Temperature Coefficient Isc %/K 0.03 Temperature Coefficient Voc %/K . 0.20 Temperature Coefficient Pmax NOCT (± 2°C) Operating temperature %/K oC nC -0.38 45 -40/+85� PropertiesMechanical .. Module weight (± 1 ka _ k� f 19 Dimensions (H x L x D; ± 1 mm) mm 1650 x 990 x 38 Maximum surface load (wind/snow)* N/mz 5400 Hail impact resistance o 25 mm at 83 km/h Cells _ _ _ 60 - Si monocrystalline - 5 busbar-156.75 x 156.75 mm Glass 3.2 mm high transmittance, tempered, antireflective coating Backsheet _ _ Multilayer polyester -based Frame Anodized Al (Black) Bypass diodes 3 diodes, 20SQ040 (45V/20A) IP67/IP68 Junction Box Cables and connectors (See installation manual) 1200 mm o 5.7 mm (4 mni MC4 compatible Module product workmanship warranty Monocrystalline _ 2_5 years* Linear power performance guarantee _ 30 ey ars Monocrystalline ULC ORli1OMMUL 1703, IEC 61215, IEC 61730-1 and IEC 61730-2 Certified. Product FSEC and CEC listed. IEC 62716 Ammonia Corrosion, IEC 61701:2011 Salt Mist Corrosion Certified UL Fire Rating: Type 2 (Type 1 on request) Factory f IS09001:2015 ' LL Warning: Read the installation and User Manual before 1 handling, installing and operating modules. Third -party generated pan files from 'e su Fraunhofer-Institute for Solar Energy "Hwomw Systems ISE are available (DNV-GL) for download at: 1ti // rv.wwu www.silfabsolar.com/downloads .cwnlnrs ECAM ... Modules Per Pallet: 26 ..e Pallets Per Truck: 36 :::Modules Per Truck: 936 Silfab Solar Inc. 240 Courtneypark Drive East --'.� Mississauga ON L5T 2Y3 Canada S ( I i C3 L) Tel +1 905-255-2501 Fax +1 905-696-0267 SOLAR info@silfabsolar.com www.silfabsolar.com �l ® Silfab Solar Inc. �r 800 Cornwall Ave Bellingham WA 98225 USA Tel +1 360-569-4733 arms, 1, Kok 1 KouMlnp Slot c.c Pro01e View �din araunw All Dlm.n.I-. In mm H lee rol.r.nc..: Al.. xoblopr.nc..:m.zmm Dnwlne•norloee.k Y 6 5 Single Phase Inverter Z with HD -Wave Technology rn for North America X SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US rn solar =- — V1 ® solar -..= a ■a.� • } u f i Optimized installation with HD -Wave technology I Specifically designed to work with I Extremely small power optimizers I Record -breaking efficiency I Built-in module -level monitoring 1 Fixed voltage inverter for longer strings f Outdoor and indoor installation I Integrated arc fault protection and rapid shutdown for 1 Optional: Revenue grade data, ANSI C12.20 NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5% accuracy) Ir L17 SA certified, for CPUC Rule 21 grid compliance solaredge.com s v l a r, g"_' Single Phase Inverter with HD -Wave %chn® Ogg/ for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V AC Output Voltage Min -Nom -Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (211 - 240 - 264) AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229) ✓ ✓ ✓ Vac AC Frequency (Nominal) 59.3 - 60 - 60.50) Hz Maximum Continuous Output 12.5 16 25 32 42 47.5 A Current @240V Maximum Continuous Output - 16 24 - - 48.5 A Current @208V GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V 5100 - 7750 - 15500 W Transformer -less, Ungrounded Yes Maximum Input Voltage Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V('I 8.5 10.5 13.5 20 27 30.5 Adc Maximum U". t Current @208VO - 9 - 13.5 - 27 Adc Max. Input Short Circuit Current 45 Adc Reverse -Polarity Protection Yes Ground -Fault Isolation Detection 600ko Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W ADDITIONAL FEATURES Supported Communication Interfaces Revenue Grade Data, ANSI C12.20 Rapid Shutdown - NEC 2014 and 2017 690.12 STANDARD COMPLIANCE Safety Grid Connection Standards Emissions INSTALLATION SPECIFICATIONS RS485, Ethernet, ZigBee (optional), Cellular (optional) Optional(') Automata[ Ftapid ShMovvn upnn AC GTid Mcanned UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 IEEE1547, Rule 21, Rule 14 (HI) FCC Part 15 Class B AC Output Conduit Size / AWG Range 1" Maximum / 14-6 AWG 1" Maximum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Rartge 1" Maximum / 1-2 strings / 14-6 AWG 1" Maximum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch tENWxD) 17.7 x 14.6 x 6,8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22110 25.1 / 11.4 26.2 / 11,9 38.8 / 17.6 lb / kg Noise < 25 1. <50 dBA Cooling Natural Convection Operating Temperature Range -13 to +140 / -25 to +60143 (-407 / -40`C option)(') `F / -C Protection Rating NEMA 4X (Inverter with Safety Switch) ca For other regional settings please contact SolarEdge support u' A higher current source may be used; the inverter will limit its input current to the values stated 01 Revenue grade inverter P/N: SExxxxH-USOOONNC2 For power de -rating information refer to: https://www.solaredge.corrVsites/dLfaulVfiles/se-temperature-derating-note-na.pdf -40 version P/N: SErwr.H-USOODNNU4 O SolarEdge Technologies, Inc, All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All RoH S other trademarks mentioned herein are trademarks of their respective owners. Dale: 03/2019N01/ENG NAM Subject to change without notice, Power Optirnizer For North America P320 / P340 / P370 / P400 / P405 / P505 25 YEAR WARRANTY l PV power optimization at the module -level Specifically designed to work with SolarEdge inverters Up to 25% more energy Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading / Flexible system design for maximum space utilization N m X / Fast installation with a single bolt Next generation maintenance with module - level monitoring / Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) / Module -level voltage shutdown for installer and firefighter safety solaredge.com so I a r�7 Power Optimizer For North America P320 / P340 / P370 / P400 / P405 / P505 INPUT Rated Input DC Powernl 320 1 340 370 400 80 405 125121 505 W Absolute Maximum Input Voltage (Voc at lowest 10Mperalulej 48 60 87t2) Vdc MPPT QpeTVN Range 8 - 48 B - 60 8 - 80 12.5 -105 12.5 - 87 Vdc Maximum Short Circuit Current (Isc) 11 10.1 14 Adc Maximum DC Input Current 13,75 1 12.5 175 Adc Maximum Efficiency 99.5 % WL&ghted Wterlcy 98.8 98.6 % Overvoltage Category 11 OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 1 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power On irrlfzef 1 ± 0.1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0 , UV Resistant RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compabble inverters All SolarEdge Single Phase and Three Phase inverters Dimensions(WxLxH) 129x153x27,5/5,1x6x1,1 129 x 153 x 33,5 / 5.1x6x1,3 129x159x49.5/ 5.1x6.3x1.9 129x162x59/ 5.1x6.4x2.3 mm/in Weight (ImWing cables) 630 / 1A 1 750 / 1,7 845 / 1.9 1064 / 2.3 gr / lb Input Connector MC4131 Single or dual MC4j M) MC41'I lrlput Wire Length Q16 / 0,52 m / ft Output Wire Type / Connector Double Insulated / MC4 Output Wire Length 0.9 / 2.95 1.2 / 3,9 m / ft Operating Temperature Range(') -40 - +85 / -40 - +185 -C / °F Protection Rating IP68 / NEMA6P Relative Humidity 0 -100 % 11) Rated power of the module at STC will not exceed the optimizer "Rated Input DC Power". Modules with up to +5% power tolerance are allowed 0 NEC 2017 requires max input voltage be not more than 80V nl For other connector types please contact SolarEdge :4) For dual version for parallel connection of two modules use the P405. In the case of an odd number of PV modules in one string, installing one P405 dual version power optimizer �51 For ambient temperature above +85"C / +185°F power de -rating is applied Refer to Power Optimizers Temperature De -Rating Technical Note for more details. Minimum String Length I P320, P340, P370, P400 8 10 18 (Power Oplimixers) P405 / P505 6 8 14 Maximum String Length 25 25 SON (Pol,wmr O irrlize 5700 (6000 with Maximum Power per String SE7600-US - SE11400- 1 5250 6000j9) 12750110f W Ll Parallel Strings of Different Lengths or Orientations I Yes (e) For detailed string sizing information refer to: http://w .solaredge.com/sites/default/files/string-sizing-na.pdf m It is not allowed to mix P405/P505 with P320/P340/P370/P400 in one string A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement For SEl4.4KUS/SE43.2KUS: It is allowed to install up to 6,500W per string when 3 strings are connected to the inverter (3 strings per unit for SE43,2KUS) and when the maximum power difference between the strings is up to 1,000W For SE30KUS/SE333KUS/SE66.6KUS/SE100KUS: It is allowed to install up to 15,DOOW per string when 3 strings are connected to the inverter (3 strings per unit for SE66.6KUS/SEl00KUS) and when the maximum power difference between the strings is up to 2,000W ® SolarEdge Technologies Ltd All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc T All other trademarks mentioned herein are trademarks of their respective owners_ Date: OB/2n19NO2/ENG NAM Subject to change without notice. Am. . RoH S Intertek Y4" BOLT LOCATION BOLT LOCATION IgI U N I RAC 1411 BROADWAY BLVD NE ALBUQUERQUE, NM 87102 USA WWW.UNIRAC.COM 31F 4 PRODUCT LINE: SOLARMOUNT DRAWING TYPE: PART DETAIL DESCRIPTION: LIGHT RAIL PREVISION DATE: %. October 2016 -- i Standard Rail Lengths: 168" 240" DRAWING=SCALEALL DIMENSI PRODUCT PROTECTED BY ONE OR MORE US PATENTS LEG A L NOTICE SETEE� Part#1 BoxQuantity screwy size 17585 10 Hooks Not Included 17586 1 [Hook Not Included 17587 10 Hooks & 20 Screws 5116" x 3" 17588 1 Hook & 2 Screws 5116" x 3" 17589 10 Hooks & 20 Screws #14 x W 17618 1 Hook & 2 Screws #14 x 3" Type 304 Stainless Steel For Side Mount Rails FReV1 Letter Description Size/Length Use our #14 or 511S' Solar Mounting Sarews A 54kA rnm � � 7cc:D�cc:)� c7C C� t 22mm 36mm 25.5,Umm W p 6m j 1 B $5mrn Rail Slot Accepts 5416` or 318' Botts m 9 5° c - 8.70mm 21 mm 3f3.5f�mm � ❑ .. -- 8.76mm — i- 120mrn 140m' m th A Mounting Screw Slats 9mm x 18mrn @ Rail Slot Side 1 orrrrn x 46m C Le of Roar Hoak � 179.5tfmrn D Bottom End to To :<�r>Id 165.3�mm-173.5�mm E i`hio�ss Bmm 5830 Las P®sitar Road, Livermore, California 84551 13948 Airway Drive, Rack Hill, South Carolina 29732 Phone: (844)_6/1-E31345 1 Fax: (800)-689-1915 ' www.solarraafhoak.m salarroafhaok.aarrt is a division of Qtaickscrews International Corp. 1�-4. �7_ M U151 b It i Ultra Flex 18, .000f..Mw Adhes-lvelftaf nt Prevents Roof Leake.and Broken rite ROOF TILE l SHINGLES 1 SHEET MIR'AE 1 fLASHIHG I HATS I GUTTERS I TRIM I NEW (ANSiitfJMON I REPAIRS Roofs are on the front line in preventing water intrusion I [high -Grade Polyurethane Formulation and are subjected to' the most extreme wind and weather. Permanently Secures Roof Tile conditions. To prevent roof damage and leaks, an adhesive/ tikon-Shrinking, Permanently Flexible sealant must be a standout performer. RainBuster' 850 Roof rile Adhesive/Sealant is by LN Resistant♦ Flexes to Prevent Broken Ties Ultra -Flexible specified leading buitders and trusted .by quality -minded contractors 1- Withstands Extreme Wind, and FootTraffic to prevent root IeaKs. Unlike traditional roofing cements I- Seals Roofing Joints including flashing and mastics. RainBuster 850 offers a high-grade polyurethane k9 Withstands `Extreme Weather &Temperature formulation, permanent flexibility and powerful adhesion. �. Non -Sag to Prevent Tile When used as a roof the adhesive., RainBuster 850 shines � Adheresto Darmp Surfaces as it flexes'with hurricane force wind uplift, foot traffic, and 10 P8intnble{See'Pa]n6ng:Sect1on) seismic activity to prevent broken tiles. When applied to I* Non -Flammable flashing, vents and gutters, RainBuster 850 permanently ;a VOC, CARO, and AQMD Compliant seals joints to effectively divert water away from the home. OP. Lifetime Wan-anty The Ultimate Roof Tile Adhesive/S.Want �.,�_. .. z. _ _ -.. �.�� - • . tip_ ,�., • ' j VQ SHEETINDEX PV-1 SOLAR LAYOUT PV-2 ATTACHMENT DETAILS PV-3 ELECTRICAL CALCS PV-3A ELECTRICAL LINE DIAGRAM PV-4 PLOT PLAN NOTES: - Solar Photovoltaic System to be installed on residential structure. -Design complying with the latest edition of California Electrical Code, NEC and all local ordinances and policies. -The project has been designed in compliance with the CBC section 1609 to withstand a minimum 110 MPH wind load. - Per sections R314 & R315 within the 2016 California Residential Code (CRC), it's required that smoke alarm and carbon monoxide detectors are retrofitted into the existing dwelling for permits with repairs or additions exceeding $1,000. - Working distances around the existing electrical equipment as well as the new electrical equipment will be maintained in accordance with CEC 110.26 - This system will not be interconnected until approval from the local jurisdiction and the utility is obtained. -This system is a utility interactive system with no storage batteries. -The Solar Photovoltaic installation shall not obstruct any plumbing, mechanical or building roof vents. - When a backfed breaker is the method of utility interconnection, breaker shall not read Line and Load. - All PV equipment shall be listed by a recognized testing lab. - Notify serving utility before PV system activation CODE COMPLIANCE PROJECT DESIGNED BASED ON 2016 CEC ALL SUPPLIED EQUIPMENT IS UL LISTED 2016 CALIFORNIA BUILDING CODE 2016 CALIFORNIA ELECTRIC CODE 2016 CALIFORNIA FIRE DEPARTMENT CODE 2016 CALIFORNIA RESIDENTIAL CODE 2016 ENERGY COMPLIANCE T-24 2014 NATIONAL ELECTRIC CODE BACKYARD GATE ROOF ACCESS PER _ CRC R324 6 SYMBOL LEGEND ATTIC VENTS MECHANICAL & PLUMBING VENTS SOLAR MODULES FIRE ACCESS PATHWAY CONDUIT MAIN SERVICE PANEL AND UTILITY METER INVERTER (INTEGR. DC DISC.) AC DISCONNECT PV METER JUNCTION BOX GAS METER PROPERTY 0 W > _ C= O _ W N N UCJ_ W LL1 G J j - "' NEW 5.12 kW (DC) system osyGgr REPLACES EXISTING R�Fcr 4.26 kW (DC) system SOLAR LAYOUT SCALE: 3132"=1'-0" i3 ' o 13 PETERSENUEAN YY.I H� ImponmM Cvnbuyy,��lyyry AMERICA AMERIGI.. ANIERMA 1820 CONTAINER CIRCLE 0 JURUPA VALLEY. CA 92509 27JAM � wxw.P2t an.cam a NSE o 1050201 PROJECT NAME * 9 ,lDS I A RE CT. 9 L A 92253 �1V1� 49.00 PV DICTION: QUINTA, CITY OF JB ., (16) SILFAB SOLAR INC SLA320M [BLKI (1) SOLAREDGE SE5000H-US (240V) �^ DRAWING NOTES: MODULE RATED AT: _ a2OW MULTIPLY BY CITY OF MODULES: 16 ARRAY SYSTEM SIZE 5.12 kW SYSTEM A2IMUTH: 2290 ROOF PITCH: -9*= 2/12 MOUNTING HEIGHT: 1-STORY ORIENTATION OPTIONS ARE PRELIMINARY, AND a ARE SUBJECT TO REVISION FOR OPTIMAL USE SOLAR ARRAY LOCATIONS ARE TO BE REVIEWED AND APPROVED BY OWNER AND/OR a ARCHITECT OF RECORD TO VERIFY SYSTEM LOCATION, FOR VENTILATION OBSTRUCTION jE AND POSSIBLE RELOCATION OF VENT AND/OR a PIPE JACKS. FIELD VERIFICATION OF ROOF STRUCTURE, AND SOLAR ARRAY LOCATION IS REOUIRED PRIOR TO INSTALLATION FOR ALL EXISTING STRUCTURES WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED. �V ARCKITECTIFIELD DRAWING INFO RMA7IQN j PERMITTING JW 08/26/2019 A DOVMSI2ED PV SYSTEM JW OB106l2015 3 PV-1 M-J © 2018 PETERSEN SOLAR &ROOFING INC ,ALL RIGHTS RESERVED - Maximum roof load: 2.63lbsi Maximum point load: 26.91 Model: Silfab Solar Inc SLA320M [Blk] Weight: 41.8 Lbs Width: 38.97 Inches Length: 64.96 Inches PARTIAL ROOF FRAMING PLAN SCALE: 3J32"=1'-0" 1l3`L MAX. TYP. W D- 0 co U_ O O D_ t 4811 r L = X" O.C. MAX 2 TYPICAL RACK MOUNT LAYOUT SCALE: 1/2"=1'-0" SOLAR PANEL CONCRETE S-TILE UNIRAC MID CLIP W/T-BOLT & FLANGE NUT' UNIRAC ALUM. SUPPORT RAIL' (2) 6/16" x 4" SS LAG BOLT INTO TRUSS(ES) 2 1/2" MIN. PENETRATION W/ROOF SEALANT, TYP. 1131 MAX. P. N M Z, LIJ ;E O Q YO I J U O C7 a- C/) W } C+'rJ 0 PETERSENDI-AJ,t al H-,rat `nF•,wg�-n,.-H Cc:Yrlw: af•iEF2u A'•1f'i1' 1820 CONTAINER CIRCLE JURUPA VALLEY, CA 92509 P:(951)2Tfi gBo vNMI. f5 A .C9F15 ICE N 05D201 PROJECT I. UTi . , i �1 ■ (16) SILFAB SOLAR INC SLA320M [BLKI (1) SOLAREDGE SE5000H-US (240V) DRAWING NOTES: 320W MODULE RATED AT: 30-16 X 3/4 MULTIPLY BY OTY. OF MODULES: 16 HEX HEAD BOLT �318.16 ARRAY SYSTEM 5.12 FLANGE NUT SIZE 0 SYSTEM AZIMUTH 22 90_ 2/12 GUICKSCREW 90' SS ROOFPITCH: PILE HOOK Wl 1-STORY FLASHING MOUNTING HEIGHT: - s ORIENTATION OPTIONS ARE PRELIMINARY, AND 5 ARE SUBJECT TO REVISION FOR OPTIMAL USE SOLAR ARRAY LOCATIONS ARE TO BE REVIEWED AND APPROVED BY OWNER AND/OR a ARCHITECT OF RECORD TO VERIFY SYSTEM LOCATION, FOR VENTILATION OBSTRUCTION IjE AND POSSIBLE RELOCATION OF VENT AND/OR a PIPE JACKS ! FIELD VERIFICATION OF ROOF STRUCTURE, AND $ SOLAR ARRAY LOCATION IS REQUIRED PRIOR TO INSTALLATION FOR ALL EXISTING STRUCTURES WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED. \2x4 TRUSS ARCHITECTIFIELD DRAWING INFORMATION @ 24" OC TYP PERMITTING JW 06W2010 '!j' A I DOMSVED PV SYSTEM I JW I D61061201i CONCRETE S—TILE — QUICKSCREW 900 SS TILE HOOK SCALE 1" = 1' A PV-2 ' x © 2018 PETERSENDEAN SOLAR & ROOFING INC, ALL RIGHTS RESERVED LABELS NEC 690,5(C) - AT THE INVERTER AND/OR GROUND FAULT INDICATOR LOCATION (AND ALL BATTERY LOCATIONS IF APPLICABLE): WARNING ELECTRICAL SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED NEC 690.13 (B), 690.15(A)(4) - ON ACIDC DISCONNECT: AC PHOTOVOLTAIC DISCONNECT I DC PHOTOVOLTAIC DISCONNECT NEC 690,17 - AT JUNCTION BOX, COMBINER BOXES AND ACIDC DISCONNECTS: WARNING ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.35(F) - UNGROUNDED PV SYSTEMS ONLY AT EACH JUNCTION BOX, COMBINER BOX. DISCONNECT AND DEVICE WHERE THE UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE: WARNING ELECTRICAL SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED NEC 690.56(C) - AT PV SYSTEM DISCONNECT PHOTOVOLTAIC $VSTEM EQUIPPED WITH RAPID SHUTDOWN NEC 690.53 - ON DC DISCONNECT: PHOTOVOLTAIC SYSTEM DC SYSTEM SPECIFICATIONS OPERATING CURRENT: 13,6 A OPERATING VOLAGE 360 V MAX SYSTEM VOLTAGE: 460 V MAX SYSTEM CURRENT, 30 A NEC 690.52 - ON AC DISCONNECT POINT OF INTERCONNECTION: PHOTOVOLTAIC SYSTEM AC SYSTEM SPECIFICATIONS MAX AC OUTPUT CURRENT! 21 A OPERATING AC VOLTAGE! 240 V OPERATING AC POWER: 4647 W OPERATING AC FREQUENCY: 60 Hz MAXIMUM OCPD RATING: 30 A NEC 705.12(D)(2) - BY BREAKER AT DISTRIBUTION EQUIPMENT: WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE NEC 705,10, 705.12(D)(3)- AT SERVICE EQUIPMENT LOCATION: CAUTION THE ELECTRICAL SYSTEM IS ALSO SERVICED BY A PHOTOVOLTAIC SYSTEM CSFM - DC CONDUIT EVERY 10' INTERIOR/EXTERIOR WARNING PHOTOVOLTAIC POWER SOURCE PLAQUES SHALL BE PLASTIC ENGRAVED IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP -RIVETS OR ADHESIVE. ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF CALIFORNIA ELECTRICAL CODE WILL BE INSTALLED AS REQUIRED, ALTERNATE POWER SOURCE PLACARD SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINE PRINTED LETTERS IN A CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE ATTACHED BY POP RIVETS OR SCREWS OR OTHER APPROVED METHOD, IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. PHOTOVOLTAIC DC CONDUCTORS SHALL BE LABELED, -CAUTION DC CIRCUIT" OR EQUIVALENT EVERY 5 FT AND KEPT MINIMUM 18` BELOW THE ROOF SURFACE, EXPOSED NON -CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENTS, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A) REGARDLESS OF VOLTAGE, EACH MODULE SHALL BE GROUNDED USING THE SUPPLIED CONNECTION POINT IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S INSTRUCTIONS. �1 IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE, PHOTOVOLTAIC EQUIPMENT SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL ONLY BE INSTALLED BY QUALIFIED PERSONS ALL CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT EQUIPMENT GROUNDING CONDUCTORS SMALLER THAN 6AWG SHALL BE PROTECTED IN A RACEWAY, I Max Branch required DC conductor ampacity (2560W)/(38OV)(1.25) = 8.4A AWG ##10, derated ampacity: (40)(0.58)(1) = 23.2A 23.2A > 8.4A, therefore DC wire size is valid. AC required conductor ampacity (21)(1.25) = 26.25A AWG i#1Q derated ampacity: (40) (0.82)(1) = 32.8A 2.8A > 26.25A, therefore AC wire size fs valid, Note-. Conduit shall be installed Min 1/2" above roofs urface PROVIDE SMOKE ALARMS AT THE FOLLOWING LOCATIONS AND NOTE ON THE PLANS; (R314.3 CRC) A OUTSIDE EACH SEPERATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDROOMS, 6, IN EACH ROOM USED FOR SLEEPING PURPOSES, C. IN EACH STORY. INCLUDING BASEMENTS. IN SPLIT LEVEL UNITS WITHOUT AN INTERVENING DOOR BETWEEN ADJACENT LEVELS, A SMOKE ALARM INSTALLED ON THE UPPER LEVEL SHALL SUFFICE PROVIDED THAT THE LOWER LEVEL IS LESS THAN ONE FULL STORY BELORE THE UPPER LEVEL. D. ALARMS SHALL BE INTERCONNECTED SUCH THAT THE ACTUATION OF ONE ALARM SHALL ACTIVATE ALL ALARMS, E. ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WITH BATTERY BACKUP. F APPROVED COMBINED SMOKE ALARMS AND CARBON DIOXIDE ALARMS SHALL BE ACCEPTABLE. A CARBON MONOXIDE DETECTOR SHALL BE INSTALLED IN THE SPECIFIC EXISTING DWELLING UNIT THAT HAVE ATTACHED GARAGES OR FUEL-WRNING APPLIANCES FOR WHICH A PERMIT IS ISSUED FOR AL TERATIONS, REPAIRS. OR A00T10NS EXCEEDING $1.000.00. LISTED SINGLE- OR MULTI -STATION CARBON MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE OF EACH SEPERATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS AND ON EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS. COMBINED SMOKEICARBON MONOXIDE ALARMS MAY BE USED. THE ALA M SHALL RECEIVE ITS PRIMARY POWER PROM INS BUILDING WIRING EXPECT 1'f IS PERMITTED TO BE SOLEY BATTERY OPERATED WHERE REPAIRS OR ALTERATIONS DO NOT RESULT IN THE REMOVAL OF WALL AND CEILING FINISHED OR THERE IS NO ACCESS BY MEANS OFF AN ATTIC. SHOW ON THE PLANS (R315 CRC) COMPLY WITH CEC SEC. 690.15 (A),4 AND INSTALL A PLAQUE IN ACCORDANCE WITH SEC. 705. 1 OAS FOLLOWS: 705.10 DIRECTORY: A PERMANENT PLAQUE OR DIRECTORY, DENOTING AN ELECTRIC POWER SOURCES ON OR IN THE PREMISES, SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT LOCATION AND AT LOCATIONS OF ALL ELECTRIO POWER PRODUCTION SOURCES CAPABLEOR BEING WMACONNECTED. PHOTO -VOLTAIC PANEL THERE ARE NOT INTEGRAL PART OF THE ROOF COVERING SYSTEM SHALL BE INSTALLED WITH A MINIMUM THREE (3) INCH CLEARANCE FROM THE SURFACE TO THE PANEL COMPLY WITH CEC ARTICLE 250.66 FOR EXISTING RESISTANCE OF ROD. PIPE. AND PLATE ELECTRODES. A SINGLE ELECTRODE CONSISTING OF A ROD, PSPE. OR PLATE THAT DOES NOT HAVE A RESISTANCE TO GROUND OF 26 OHMS OR LESS SHALL BE AUGMENTED BY ONE ADDITIONAL ELECTRODE OF ANY OF THE TYPES SPECIFIE D BY 250.62(A)(4) THROUGH (AKS} WHERE MULTIPLE ROD, PIPE. OR PLATE ELECTRODES ARE INSTALLED TO MEET THE REQUIREMENTS OF THIS SECTION. THEY $HALL NOT BE LES$ THAN 1.8 M (6 FT) APART. SHALL PROVIDE AN AUXILIARY GROUNDROF 1T IT CANNOT BE PROVEN THAT THE EXISTING GROUNDING HAS HAVE A RESISTANCE TO GROUND OF 25 OHMS OR LESS. Si If ab Solar Inc SLA320M f Bl k 5 Voc, 33.7 Vmp, 20 Vnom 9.96 Isc 9.5 Im 600 V, UL E42728, NEMA 3,4,4x,6,12,13 El PETERSEN!"!E.<=;�! 1820 CONTAINER CIRCLE JURUPA VALLEY, CA 92509 P:(951)276-4$ wWrV.DDIC QB CORI N 050201 C-46, C 0 PROJECT NAME: SOlarEd eSE5000H-US(240Vj 1 t 7 1, NEMA 3R, IEEE 1547 1 HA No Output Voltage 240 V E I V 10AI WU Lp UL%.UIICIIL LJ./AI No. f Modules - Branch 1 81 No. f Modules - Branch 2 g No, 4fModules - Branch 2 0 M&A her of MM, Ii a .1e Record low terne 13°F Max AC Output Current 21 A Ppmting AC Voltage 240V Operating AC Power 4647 W ,Operating AC Frequency 60 Hz Max OCPD Rating 30 A QUPUIF_UL31r rJLV I Max Output Voltage 60VDC, Ima_x 15A UL1741. IEC62109-1, NEMA 6P RESIDENCE 81392 JOSHUA TREE CT, LA QUINTA, CA 92253 JOB # 46949.00 JURISDICTION: LA QUINTA, CITY OF (16) SILFAB SOLAR INC SLA320M [BLK] (1) SOLAREDGE SE5000H-US (240V) DRAWING NOTES: MODULE RATED AT: . 32QW MULTIPLY BY CITY. OF MODULES: 16 ARRAY SYSTEM SIZE: 5.12 kW Ay� SYSTEM AZIMUTH: 2290 a ROOF PITCH: 90- 2/1 2 MOUNTING HEIGHT: _ 1-STORY v� ORIENTATION OPTIONS ARE PRELIMINARY, AND ARE SUBJECT TO REVISION FOR OPTIMAL USE. �EX PV EQUIPMENT i XANTREX Gr3.3N-NA-240/208 UL 1741, NEMA 3R, IEEE 1547 Nom Output Voltage 240 V Max Output Current 13.8 A EATON DG222URB UL E5239, NEMA 3R I ` ' 60 A, 240 V, NON -FUSIBLE o 1 V .3 -:1 � - n 2018 PETERSENDEAN SOLAR & ROOFING $ INC., ALL RIGHTS RESERVED SOLAR ARRAY LOCATIONS ARE TO BE REVIEWED AND APPROVED BY OWNER ANDIOR ARCHITECT OF RECORD TO VERIFY SYSTEM LOCATION, FOR VENTILATION OBSTRUCTION AND POSSIBLE RELOCATION OF VENT AND/OR PIPE JACKS, FIELD VERIFICATION OF ROOF STRUCTURE, AND SOLAR ARRAY LOCATION IS REQUIRED PRIOR TO INSTALLATION FOR ALL EXISTING STRUCTURES WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED. 101 ARr:HITFr.TfFIFI n-1 amp -■ PHOTOVOLTAIC ARRAY BRANCH CIRCUIT 1 = 8 MODULES DC -DC POWER OPTIMZER • . . • BRANCH CIRCUIT 2 = 8 MODULES EGC — AWG #10 PV WIRE IN FREE AIR POS = RED NEG = BLACK AWG #6 G = BARE CU PHOTOVOLTAIC ARRAY BRANCH CIRCUIT 1 = 31 MODULES DC -DC - POWER OPTIMZER • • • BRANCH CIRCUIT 2 = 31 MODL EGC INVERTER (240V) &INTEGRATED JUNCTION DC DISCONNECT BOX W/ INTERNAL GFDI & AFCI THWN-2 IN 3/4" EMT AWG #10 POS = RED NEG = BLACK AAIG #8 G = GREEN EXISTING PHOTOVOLTAIC ARRAY TO BE REPLACED PV BREAKER 30 A DPB SQUARE D HOM230 OR COMPATIBLE BREAKER LOCATED FARTHEST FROM MSD THWN-2 IN 3/4" EMT AWG #10 L1 = BLACK L2 = RED N = WHITE AWG #8 G = GREEN JUNCTION 60 A RATED BOX INVERTER (24OV) AC DISCONNECT PV METER (240V) (240V) e (E) CONDUCTORS (E)CONDUCTORS (E)CONDUCTORS 1 EXISTING 225 A RATED -� SQUARE D MAIN SERVICE '- PANEL r� 200 A MAIN DISCONNECT &DIRECTIONAL UTILITY METER 0 1 PHASE, 3 WIRE 120/240 V NEW, IF NO EXISTING GROUNDING ELECTRODE TO A 20A DPB @ MSP 0 PETERSENN-1%r•,.! M I I Irrv; I nrnr.nn—I ComM Iv �EAICh AtilEr21:.�. 1820 CONTAINER CIRCLE JURUPA VALLEY. CA 92509 P' (951) 276-48,DD 8�e1 PROJECT NAME: HANSEN RESIDENCE 81392 JOSHUA TREE CT. LA QUINTA, CA 92253 JOB # 46949.00 JURISDICTION: LA QUINTA, CITY OF (16) SILFAB SOLAR INC SLA320M [BLK] (1) SOLAREDGE SE5000H-US (240V) DRAWING NOTES:` IAODULE RATED AT: 320111► AULTIPLY BY OTY OF MODULES 16 1RRAY SYSTEM SIZE - . - 5.1_ _ 2 kW ;YSTEM AZIMUTH: - 2290 tOOF PITCH: 9'- 2/12 4OUNTING HEIGHT: 1-STORY )RIENTATION OPTIONS ARE PRELIMINARY, AND IRE SUBJECT TO REVISION FOR OPTIMAL USE ;OLAR ARRAY LOCATIONS ARE TO BE tEVIEWED AND APPROVED BY OWNER AND/OR kRCHITECT OF RECORD TO VERIFY SYSTEM OCATION, FOR VENTILATION OBSTRUCTION IND POSSIBLE RELOCATION OF VENT ANDIOR IPE JACKS IELD VERIFICATION OF ROOF STRUCTURE, AND ;OLAR ARRAY LOCATION IS REQUIRED PRIOR O INSTALLATION FOR ALL EXISTING TRUCTURES WHERE NEW SOLAR ARRAYS ARE 0 BE INSTALLED ARC: Vifr Fr: TfFIFI n nOA%NIN!_ tMCnOU—.TI .t kiLY��CdC.RfP,]3`�GFiIt�IU%tF� DOVIONSIZED PV SYSTEM n i♦ P V- 3A © 2018 PETERSENDEAN SOLAR & ROOFING -INC, ALL RIGHTS RESERVED CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: � I BACKYARD SOLAR PV ON ROOF INVERTER MAIN PANEL & METER & MAIN SERVICE DISCONNECT El PETERSENDEAN EIRa a AAnfume ImvqQ.�^.„�errt corcnncr 1C%A AME= 1920 CONTAINER CIRCLE JURUPA VALLEY, CA 92509 P: (951) 2764 90 ww Wte-d.-.c— CA LICENSE No 1050201 C-46, C-36, C-20 HANSEN RESIDENCE 81392 JOSHUA TREE CT. LA QUINTA, CA 92253 JOB # 46949.00 JURISDICTION: LA QUINTA, CITY OF (16) SILFAB SOLAR INC SLA320M [BLKI (1) SOLAREDGE SE5000H-US (240V) M fli'l , • 1 © M18 PETERS EN DEAN ROOFING &SOLAR SYSIMM Wt'- A" MGRESERVED f r 1� SWIMMING J-� POOL \ I ), pol c SOLAR PV ON ROOF INVERTER MAIN PANEL & METER & MAIN SERVICE DISCONNECT PLOT PLAN SCALE:1 "=20' D El PETERSENDFAN �f ,I llgrt•bryrp,� mlCatlisiw AIr1ERiLA M1EltICA AMERICA 1620 CONTAINER CIRCLE JURUPA VALL£ A 92509 P:(951)27G• www,pete ends a SE No W205 CA6, • c-z n I G.a. PROJECT NAME I HANSEN RESIDENCE 81392 JOSHUA TREE CT. LA QUINTA, CA 92253 JOB # 46949,00 JURISDICTION: LA QUINTA, CITY OF (16) SILFAB SOLAR INC SLA320M (BLK) (1) SOLAREDGE SE5000H-US (240V) IRAWING NOTES: MODULE RATED AT: 320W MULTIPLY BY OTY. OF MODULES: 16 ARRAY SYSTEM SIZE 5— VV 1�y1 SYSTEM AZIMUTH: 9290 Tom` ROOF PITCH: 90= 2/1�2 MOUNTING HEIGHT: 1—STORY 1/ ORIENTATION OPTIONS ARE PRELIMINARY, AND ARE SUBJECT TO REVISION FOR OPTIMAL USE � I SOLAR ARRAY LOCATIONS ARE TO BE REVIEWED AND APPROVED BY OWNER AND/OR a ARCHITECT OF RECORD TO VERIFY SYSTEM LOCATION, FOR VENTILATION OBSTRUCTION AND POSSIBLE RELOCATION OF VENT AND/OR < PIPE JACKS F FIELD VERIFICATION OF ROOF STRUCTURE, AND SOLAR ARRAY LOCATION IS REQUIRED PRIOR gg TO INSTALLATION FOR ALL EXISTING Lei STRUCTURES WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED ARCHITECTIFIELD DRAWING INFORMATION p PERMITTING Jw 06126,2010 w A DOWNSIZED PV SYSTEM I JW I NI0617010 .. PV-4 © 2018 PETERSENDEAN SOLAR & ROOFING 9 INC ALL RIGHTS RESERVED