BSOL2019-002978-495 CALLE TAMPICO T4ht D ve Qu,4& VOICE (760) 777-7125
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011
DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 10/17/2019
Permit Type/Subtype: SOLAR/THERMAL Owner:
Application Number: BSOL2019-0029 JOHN SPATH
Property Address: 81900 GOLDEN STAR WAY 81900 GOLDEN STAR WAY
APN: 764500035 LA QUINTA, CA 92253
Application Description: SPATH / ROOFTOP THERMAL POOL HEATING SYSTEM
Property Zoning:
Application Valuation: $3,000.00
Applicant: D
Contractor:
JOHN SPATH OWNER BUILDER
81900 GOLDEN STAR WAY
LA QUINTA, CA 92253 OCT 17 2019
C,N OF Ijka�INTA LIc. No.:
DESIGN &DEVELOPMENT DEI'AR'MINT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9
{commencing with Section 70001 of Division 3 of the Business and Professions Code, and
my License is in full force and effect.
License Class: _ License No.:
Date
Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any
structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the
lai leged exemption. Any violation of Section 7031.5 by any applicant For a permit
Jrbj,er's
theapplicant toacivil penalty of not more than five hundred dollars ($500))I,asowneroftheproperty, or myemployeeswith wages as their sole
pensation,will do thework, and the structure is not intended or offered for sale.
I'" own
Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
vjqiri one yearof completion, the owner -builder will have the burden of proving that he
r s e did not build or improve for the purpose of sale.).
I, as owner of the property, am exclusively contracting with licensed contractors to
co struct the project. (Sec. 7044, Business and Professions Code: The Contractors' State
Li rise Law does not apply to an owner of property who builds or improves thereon,
d who contracts for the projects with a contractor(s) licensed pursuant to the
tractors' State License Law.),
) I am exempt under Sec. W.k.C. for/Ibis reasph
Date: /4P
t:UNAFRUON ILIENDMG AGENCY
I hereby affirm under penalty 6 ry thajthis a construction lending agency for
the performance of the wor For Bch thi m t is issued (Sec. 3097, Civ. C.).
Lender's Name:
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit is
issu . My workers' Compensation Insurance carrier and policy number are:
I : _ Policy Number:
• I certify that in the performance of the work for which this permit is issued, I
shal of employ any person in any manner so as to become subject to the workers'
co ensation laws of California, and agree that, if I should become subject to the
wo ers' compensation provisions of Se t' 3700 of the Labor Code, I shall forthwith
comply with those p revisions.
Date: Al)Applica
WARNING: FAILURE TO SECURE WORK S' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLIL� RS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGE A54ROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEVS-ICEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit issued
as a result of this application , the owner, and the applicant, each agrees to, and shall
defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not
commenced within 180 days from date of issuance of such permit, or cessation of work
for 180 days will subject permit to cancellation.
certify that I have read this application and state that the above informal on is correct.
agree to comply with all city and county ordinances and state laws relati to building
:onstruction, and hereby authorize representatives of P�T� cityj enter up n the above-
'nentionedproperty for inspection purposes. r ,I // �,
Date/
Lender's Address: 1 7lrl/J Signature (Applicant or
i��
DESCRIPTION ACCOUNT QTY AMOUNT
BSAS SB1473 FEE 101-0000-20306 0 $1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
APPLIANCES, RES
101-0000-42403
0
$13.42
DESCRIPTION
ACCOUNT
QTY
AMOUNT
APPLIANCES, RES PC
101-0000-42600
0
$13.42
Total Paid for ELECTRICAL 2019: $26.84
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PERMIT ISSUANCE
101-0000-42404
0
$101.97
Total Paid for PERMIT ISSUANCE: $101.97
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SOLAR THERMAL
101-0000-42401
0
$26.83
DESCRIPTION
ACCOUNT
CITY
AMOUNT
SOLAR THERMAL PC
101-0000-42600
0
$26.83
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER SYSTEM INST/ALT/REP
101-0000-42401
0
$13.42
DESCRIPTION
ACCOUNT
QTY
AMOUNT l
WATER SYSTEM INST/ALT/REP PC
101-0000-42600
0
$13.42
Total Paid for PLUMBING 2019: $80.50
DESCRIPTION
ACCOUNT
QTY
AMOUNT
RECORDS MANAGEMENT FEE
101-0000-42416
0
$10.00
Total Paid for RECORDS MANAGEMENT FEE: $10.00
DESCRIPTION
ACCOUNT QTY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611 0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
Tw�t 4 4a"
P.O. Box 1504
LA QUINTA, CALIFORNIA 92247-1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
BUILDING & SAFETY DEPARTMENT
PROPERTY OWNER'S PACKAGE
(760) 777-7012
FAX (760) 777-7011
Disclosures & Forms for Owner -Builders Applying for Construction Permits
IMPORTANT! NOTICE TO PROPERTY OWNER
Dear Property Owner:
An application for a building permit has been submitted in your name listing yourself as the builder of the property
improvements specified at
We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of your
responsibilities and possible risk you may incur by having this permit issued in your name as the
Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision,
signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice
unless you, the property owner, obtain the prior approval of the permitting authority.
OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION
`.DIRECTIONS: Read and initial each statement below to signs you understand or verify this information.
I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder"
building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as
an 0,wner-Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person
and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those
injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers
on my property.
2. I understand building permits are not required to be signed by property owners unless they are responsible for the
ctruction and are not hiring a licensed Contractor to assume this responsibility.
3. I understand as an "Owner -Builder" I am the responsible party of record on the permit. I understand that I may protect
If from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my
W4. I understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on
e is and contracts.
5. I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value
o y construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer"
under state and federal law.
J6. I understand if I am considered an "employer" under state and federal law, I must register with the state and federal
g rnment, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment
co pen
sation for each "employee," I also understand my failure to abide by these laws may subject me to serious financial
ri. .
I understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential
res cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed
s is ontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed
un er contract with a licensed general building Contractor.
L8. I understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any
t ncial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the
workmanship or materials.
9. I understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue
vice, the United States Small Business Administration, the California Department of Benefit Payments, and the California
ision of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-
-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors.
10. I am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the
legally and financially responsible for proposed construction activity at the following address:
11. I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all
cable laws and requirements that govern Owner -Builders as well as employers.
12. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I
haW provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with
someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss
you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also
important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working
on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors,
you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers'
compensation insurance coverage.
Before a building permit can be issued, this form must be completed and signed by the property owner and returned to
the agency responsible for issuing the permit. Note: A cap of the property owner's driver's license, form notarization, or
other verification acceptable to a gene} ,is r ired be presented when the permit is issued to verify the property
owner's signature. f %
Signature of property owns f Date: ✓ r f
Note: The following Authorization Form is required to be completed by the property owner only when designating
an agent of the property owner to apply for a construction permit for the Owner -Builder.
AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF
Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize
the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder
Permit for my project.
Scope of Construction Project (or Description of Work):
Project Location or Address:
Name of Authorized Agent:
Address of Authorized Agent:
Tel No
I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above
information and certify its accuracy. Note: A copy of the owner's driver's license, form notarization, or other verification
acceptable to the agency is required to be presented when the permit is issued to verify the property owner's signature.
Property Owner's Signature: Date:
ta (2PERMIT#
af
- (;E,ll ,y ),,I ) ES ER I'
PLAN LOCATION:
Project Address: O r L0,/) Z��� � ��� L��
Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech
APN #:
Applicant Name: ✓, /�J 77/
Address:
City, ST, Zip: rlJi►�
Telephone: ,1
Email:-kAIA).
Valuation of Project $
Contractor Name:
New SFD Construction:
Address:
Conditioned Space SF
City, St, Zip
Garage SF
Telephone:
Patio/Porch SF
Email:
Fire Sprinklers SF
State Lie: City Bus Lie:
Arch/Eng Name: Construction Type: Occupancy:
Address: Grading:
City, St, Zip
Telephone: Bedrooms: Stories: # Units:
Email:
State Lie: City Bus Lie:
Property Owner's Name: TCL
New Commercial / Tenant Improvements:
Address:
Total Building SF
City, ST, Zip
Construction Type: Occupancy:
Telephone:
Email:
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
OFFICE USE ONLY
#
Submittal
Req'd
Rec'd
Plan Sets
Structural Calcs
Truss Calcs
Title 24 Calcs
Soils Report
Grading Plan (PM10)
Landscape Plan
Subcontractor List
Grant Deed
HOA Approval
School Fees
Burrtec Debris Plan
Planning approval
Public Works approval
Fire approval
City Business License
F��CL7,019
CITY C
EUILU',
PEA
DATE I 1! q _: r
SITE LOCATION
VICINITY MAP
• aoZ�
AN A
61
=kION
OR SPATH RESIDENCE
81900 GOLDEN STAR WAY
I0E LA QUINTA, 92673
f
TRUE NORTH
1M%r
f
TRUE NORTH
IF -- J 1 SOLAR POOL HEATING SYSTEM
SCOPE OF WORK
1. THE DESIGN BUILD CONTRACTORS SHALL FURNISH AND INSTALL
SWIMMING POOL SOLAR HEATING SYSTEM, INCLUDING, BUT NOT
LIMITED TO: SOLAR COLLECTORS, ASSOCIATED MANIFOLDS, SOLAR
COLLECTOR CONNECTION HARDWARE, SOLAR COLLECTOR
MOUNTING/INSTALLATION HARDWARE, DIGITAL SOLAR CONTROL
SYSTEM, AND ALL APPURTENANCES.
2. FURNISH AND INSTALL DIGITAL SOLAR CONTROLLER AC POWER
AND ROOF TOP SENSOR SHALL BE LOCATED ON THE POOL
EQUIPMENT BUILDING ROOF.
3. FURNISH AND INSTALL ROOF SUPPORTS AND COLLECTOR
ANCHORS.
4. FURNISH AND INSTALL PIPE FASTENERS, MOUNTING HARDWARE,
AND RIGID PIPE CLAMPS FOR PIPING UP THE WALL.
STANDARDS
ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE APPLICABLE
EDITIONS OF ALL NATIONAL, STATE, AND LOCAL CODES, LAWS, REGULATIONS,
AND ORDINANCES, INCLUDING THE FOLLOWING:
AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)
AMERICAN SOCIETY OF TESTING MATERIALS (ASTM)
2016 CALIFORNIA ELECTRICAL CODE (CEC)
2016 CALIFORNIA BUILDING, RESIDENTIAL, ELECTRICAL, PLUMBING
ENERGY CODES WITH LOCAL AMENDMENTS
2016 GREEN CODE
2016 COUNTY FIRE CODE
DELIVERY, STORAGE, AND INSTALLATION SHALL COMPLY WITH SPECIFICATION
SECTION 13563.
ALL PIPING SHALL BE SCHEDULE 40 PVC-ASTM FITTINGS, SOLVENT WELDED
CARBON MONOXIDE ALARMS ARE REQUIRED TO BE INSTALLED IN EXISTING
DWELLING UNITS OR SLEEPING UNITS WITH A FOSSIL FUEL BURNING HEATER
OR APPLIANCE, FIREPLACE, ATTACHED GARAGE. CARBON MONOXIDE ALARM
SHALL BE LOCATED IN EACH AREA GIVING ACCESS TO A SLEEPING ROOM AND
ON EACH STORY DWELLINGS WITH MORE THAN ONE STORY CARBON
MONOXIDE ALARMS ARE PERMITTED TO BE SOLELY BATTERY OPERATED
WHERE NO CONSTRUCTION IS TAKING PLACE.
SAFETY SIGNAGE PRESENT IN COMPLIANCE WITH CA BUILD. CODE TITLE 24
RECEIVED
OCT 0 j -2019
cffyorIAQU
b€S M AND D> aOI ENT DEMRTMENT
SHEETINDEX
P-1 VICINITY MAP AND PROJECT
LOCATION/ COVER PAGE
P-2 SITE PLAN
PT-1 POOL SOLAR SYSTEM FLOW
DIAGRAM
PT-2 POOL SOLAR ATTACHMENT
DETAIL
PT-3 POOL SOLAR CONTROL SPEC
SHEET
PT-4 POOL SOLAR COLLECTOR
SPEC SHEETS
POOL
POOL SYSTEM SIZE: 480 SQFT
OPTIMUM FLOW RATE: 48-72 GPM
DESIGN FLOW RATE: 60 GPM
CONSTRUCTION HOURS: 7AM-8PM,
M-F; 8AM-8PM, SATURDAY; NO SUNDAY
OR LEGAL HOLIDAYS.THE DISCHARGE
OF POLLUTANTS TO ANY STORM DRAINAGE
SYSTEM IS PROHIBITED. NO SOLID WASTE,
PETROLEUM BYPRODUCTS, SOILPARTICULATE,
CONSTRUCTION WASTE MATERIALS,OR
WASTEWATER GENERATED ON CONSTRUCTION
SITES OR BY CONSTRUCTION ACTIVITIES SHALL
BE PLACED,CONVEYED OR DISCHARGED INTO
THE STREET, GUTTER OR STORM DRAIN SYSTEM.
OCCUPANCY GROUP: R-3
CONSTRUCTION TYPE: V/B
SUNTREIC
Your Solar Energy Company
SUNTREK INDUSTRIES
5 HOLLAND #215
IRVINE, CA92618
C-46 LIC. #859460
(949) 348-9276
PROJECT
POOL THERMAL/
SHW SYSTEM
LOCATION
w
U }
Z Q U)
W ti cD
0-1 Q �N Z
Q
W w~ 2
_j5 J
=o� O
CL
Q°° Q
J
U) O
DESIGNER
A. HILL
COVER PAGE
REVISIONS
SHEET NO.
P-1
O
r
M
Z
Icz
D
u
23' -
DRIVEWAY
2
RESIDENCE
POOL
a l �.
PEA
GENERAL NOTES
POOL
POOL SYSTEM SIZE: 500 SQFT
DESIGN FLOW RATE: 60 GPM
CODE COMPLIENCE
1, OCCUPANCY GROUP: R-1
NUMBER OF STORIES ;1 STORY
SOLAR PANELS LOCATED ON FLAT CONCRETE TILE ROOF
2, COMPLY WITH ALL MANUFACTURERS LISTINGS AND
INSTALLATION INSTRUCTIONS,
2016 CALIFORNIA BUILDING CODE
2016 CALIFORNIA ELECTRICAL CODE
2016 CALIFORNIA ENERGY CONSERVATION CODE
2016ICC/ANSI
PLAN -POOL THERMAL SOLAR SYSTEM
DETAIL
PAGE
1. SOLAR POOL HEATING ARRAY
A
PT-4
2. ROOF MOUNT/CONNECTION DETAIL
A
PT-2
3. WALL MOUNT/CONNECTION DETAIL
B
PT-2
4. POOL EQUIPMENT
B
PT-1
5. 2" SCH. 40 PVC SUPPLY & RETURN
PIPING TO POOL EQUIPMENTAREA,
ASTM FITTINGS, SOLVENT WELDED
SUNTREK
Your Solar Energy Company
SUNTREK INDUSTRIES
5 HOLLAND #215
IRVINE, CA92618
C-46 LIC. #859460
(949) 348-9276
PROJECT
POOL THERMAL/
SHW SYSTEM
LOCATION
2
W �
U U)
Za U)
W �ti
❑�� z
� Q
W Lu _
Od O
20� n
00CL
J
VJ O
e—
DESIGNER
A. HILL
SITE PLAN
ROOF PLAN
REVISIONS
SHEET NO.
P-2
NOTES:
T CONTROL WIRING CONNECTS TO LINE
SIDE OF EXISTING POOL PUMP TIME w.
CLOCK. 120V/240VAC
ALL ROOF PIPING SHALL BE BLACK SCH. 40 PVC
ASTM FITTINGS, SOLVENT WELDED
�3:) ALL PIPING FROM EQUIPMENT TO ROOF SHALL BE SCH 40 PVC
ASTM FITTINGS, SOLVENT WELDED
4 N=NEW
E=EXISTING
POOL
POOL SYSTEM SIZE: 500 SQFT
DESIGN FLOW RATE: 60 GPM
2" PVC
FROM POOL
POOL
VACUUM RELIEF
VALVE (TYP)
SOLAR TEMPERATURE
SENSOR
(N)SOLAR DIGITAL
CONTROL PANEL
120V/240V
A
PT-4
OLAR COLLECTOR (N)
& MANIFOLD ON
m r%r\ C
NOTE:
ALL PIPING SHALL BE 2" SCH. 40 PVC
- SOLAR COLLECTOR FLOW / INSTALLATION DIAGRAM
TO POOL
SUNTREK
Your Soler Energy Company
SUNTREK INDUSTRIES
5 HOLLAND #215
IRVINE, CA 92618
C-46 LIC. #859460
(949) 348-9276
PROJECT
POOLTHERMAL/
SHW SYSTEM
LOCATION
W
W
U �
Za W
W ti CD
❑�� z
U) Q
W wz _
0a O
=off a
�-
<0 Q
n J
V! O�/
T-
DESIGNER
A. HILL
SYSTEM FLOW
DIAGRAM
REVISIONS
SHEET NO.
ELASTOMER
FABRICATED STRAP
(TYP. AT EACH MANIFOLD)
ELASTOMERIC
SEALANT
)iNCRETE TILE
1/4" DIA. x 2"
LAG SCREW
COLLECTOR
MANIFOLD. SEE
DETAIL'A', SHT. PT-3
DETAIL 'A', SHT. PT-3
WATER TUBING, SEE II
EPDM ELASTOMER
ROOF ADHESIVE C
(E) ROOF BEAM 77
SOLAR COLLECTOR MOUNTING DETAIL
ROOF MOUNT
CLAMP STRAP
2" SCH. 40 PVC SUPPLY &
RETURN PIPING TO POOL
EQUIPMENT AERAASTM
FITTINGS, SOLVENT WELDED
1/4" DIA. x 2•
LAG SCREW
PLASTIC
ANCHOR
CEMENT WALL
eB SOLAR COLLECTOR MOUNTING DETAIL
WALL MOUNT_
TITEBONDOALLWEATHER
SUNTREK BOND ROOFING SEALANT
PHYSICAL
Ze,.*. Synthetic elastomeric polymer Calculated VOC (Iess water): 389 g/L
State: Medium -viscosity mastic Wei tlallan: 9.81 lbs,
PROPERTIES
Color, bight tan FIas poini Less than Q°F.
Solids:
6 Freeze/thaw stability Will not freeze
Viscosity:130,000 cps Storage life: 12 months in tightly closed containers at 751.
APPLICATION
Application temperature: (rF. to 1001F.
GUIDELINES
Service temperatures: -2VF. to 120°F.
Method of application: Cartrid&e/caulking gun
Coverage (maximum): Approximate lengsi of bead according to bead diameter:
Container 1/8' bead 114" bead 3/8" bead
5 oz. Cartridge 4 ft.
29 oz. Cartridge 355 ft. 89 ft. 39 ft.
Working time: Approximately 10-20 minutes for a 1/4" bead
Working surfaces: Surfaces to be banded should be clean and free from excessive oil, grease, water,
dirt or any other material that may deter adhesion. Apply adhesive to each piece of furring, studs or
floor joists to be covered. When bonding subfloors or wet frozen and treated lumber, nail or screw
each sheet as recommended by the American Plywood Association.
Cleanup: Scrape off dried excess with a putty knife. Remove residue with mineral spirits or
Follow
equivalent solvent. solvent vendor's precautions when using solvents. NOTE: Test solvent
on an out-of-the-way area to make sure it will not mar or attack die surface.
PRODUCT Works extremely well in colder temperatures
• Ideal for plywood, particleboard, OSB, and wet, frozen and ACA & CCA treated lumber
FEATU R ES Fills gaps and irregularities between materials to provide a more solid backup surface
• Exceeds the performance requirements of the American Plywood Association AFG-01
Specification, ASTM D3498, ASTM C557, CAN/CGSB-71.26M and CAN/CGSB-71.25M
LI M I TATI O N S Titebond All Weather Subfloor Adhesive is not designed for continuous submersion or for use on
polystyrene foams. Forpolystyrene foam, tub surrounds and most other plastics, we recommend
Titebond Interior/Exterior Construction Adhesive.
CAUTION DANGER: EMEMELY FLAMMABLE. VAPOR HARMFUL. Contains hexane and toluene. Keep
away from heat, sparks and flame. Use only with positive cross -ventilation. Avoid breathing vapors.
STATEMENT Do not swallow. Do not allow eye contact or prolonged skin contact. Uncured product can cause eye or
skin irritation. Prolonged or repeated overexposure to solvents in uncured product can cause central
nervous system, peripheral nervous system, eye, skin, liver, kidney or respiratory system effects, FIRST
AID: If dizziness or other adverse effects are experienced, move to fresh air; call physician if discomfort
persists. If eye contact occurs, flush eyes with water for 15 minutes; contact physician immediately. If
swallowed, do not induce vomitinip contact physician immediately. Wash skin contact areas with soap
and water; contact physician if irritation persists. For additional information, refer to Material Safety
Data Sheet. KEEP OUT OF THE REACH OF CHf LDREN.
WARNING: This product contains toluene, a chemical known to the State of California to cause birth
defects or other reproductive harm.
ORDERING Units Packages
Cat. No. Size per Package Weight per Pallet
NFORMA,TION 45492 29 oz. Mini Pallet 144tubes 352 12
5491 10.5 oz. Cartridge 12 11 IV
5492 29 oz. Cartridge 12 f. _f tv [y O UTV-
UILDING DMSIO�-!
REVIEWED FOR
CODE
WNIPLIANCE
{
-_—
Important Notice: Our recommendations, if any, for the use of this product are based on tests believed to be reliable. Since the use of this product is beyond the control
of the manufacturli no guarantee or warranty, expressed or implied, is made as to such use or effects incidental to such use, handling or possession or the results to be
obtained, whether in accordance with the directions or claimed so to be. The manufacturer expressly disclaims responsibility therefore. Furthermore, nothing contained
herein shall be construed as a recommendation to use any product in conflict with existing laws and/or patents covering any material or use.
2020 Bruck Street, Columbus, Ohio 43207 International
CUSTOMER SERVICE 1-800-669-4583
TECH SERVICE 1-800-347-GLUE Franklin
www.titebond.com 02008 Franklin International. All rights reserved.
ON
S(0010� 0
UNTREK
Your Solar Energy Company
SUNTREK INDUSTRIES
5 HOLLAND #215
1RVINE, CA 92618
C-46 LIC. #859460
(949) 348-9276
PROJECT
POOL THERMAL/
SHW SYSTEM
W
U
Z
W
0
VJ
W
2
L.L
U)
LOCATION
Q
tY ti
H0)
LU
pZ
OCY
CD �
O J
0)
00
2
W
W
Z
Q
J
O
O
IZ
Q
J
O
T-
DESIGNER
A. HILL
ATTACHMENT
DETAIL
REVISIONS
ADHESIVE SPEC
SHEET NO.
PT-2
SolarTouch Control Panel
Solar Collectors
Building
Height
Additional Notes-
1 - Solar Collectors lay flat on roof, NOT TO EXCEED
3" HIGHT FROM ROOF SURFACE OR RACKING
2. Solar Collectors will not exceed maximum building height
3. Solar Energy appurtenances shall be screened to the maximum extent
possible without compromising the effectiveness of the solar collectors.
4. All PVC piping exposed to sunlight shall be protected
from UV radiation.
5. A time switch or similar control mechanism shall be installed
(existing) as apart of the pool water circulation control system
that will allow the pump to be set or programmed to run only
during off-peak electric demand period, and for the minimum time
necessary to maintain the water condition required by applicable.
Public health standards. Sec.114(b)3ii, 2016 Califirnia Energy Code.
1So `
Vouch
F
Water 60F
rget Temp 80F
System @ 0 0 0
Status Menu Less More EnW
OPERATION
Menu: Press to access menu and scroll through options.
Less/More: Press arrows to lower or raise target temperature.
Move cursor up/down to adjust setting
within menus.
Enter: Press to select a menu item. Save a setting.
Disable and Re -Enable SolarTouch system:
Press and hold Enter for three seconds.
Ralnpmal rTYPE 3)Conlml Paewenel for O Fareuppl conneclionsM
for Indoor or oNdooruse.sul�l1 No.14W1e AWccond ors
swimmingG PWVape appift0rs 3LLIS eull Wlar el heel0-0(IQ 'F}
ELECTRICAL RATINGS: E324842
INPUT POWER: 120VAC..4AMP u, 24OVAC, 2ALp.M Hz.
COld1ECF TO ORE SOLM OKY SEE AC WIRING DVZM*ME ENCLOSURE
OUTPUTS:
LOW VOLTAGE: 24 VAC, 85AMP i
HIGH VOLTAGE: 16DWED DAY CONTACT • wxw_084o VAC, mho Hz, 10 NMI
PER RELAY CONTACT OUTPUT. ;�
YP?7lkt WFE�L'X
Solar PoQ13gHlfl
ronrmr system � wnr,00n�advgnrmrgF
ACFON/RIIrNaq Voq URI+MI�1 �
g4�w1ALL 11W T4WL ,
o LA Q U I II -1
10ILDING DIVISION
EVIEIVED FOR
CODE
r-OMPLIANCE
C1.).Liquid Crystal Display (LCD): The system LCD displays backlighting for easy
viewing of the menu items and status messages. Each button press will light the
display. When an event message is displayed, the backlight will also be on.
System Status LED indicator: When indicator is green, the system is running
normally. If indicator is red an error occurred. See page 10 for error conditions.
Menu Button: Access Main Menu and exit menus. Press and hold this button to
access the Advanced Menu. Scroll through menu options. While in a menu or sub -
menu, access a previous menu level or item. If no menu activity is detected after 30
seconds, the main screen is displayed. All menu settings are permanently saved
and retained even after the unit is power off.
Less / More buttons: Lower or Raise target water temperature.
Move cursor Up/Down to adjust menu setting within menus.
Ca Enter button: Select a menu item and save a menu setting. Press this button to
view Solar water set point temperature setting. The display will automatically revert
back to the monitoring water and solar temperatures after 30 seconds from the last
selection. Note: Press and hold the Enter button to disable Heating, Cooling and
Freeze Protect (display shows "SolarTouch Disabled'). Press and hold the Enter
button again to enable SolarTouch.
SUNTREi
Your Solar Energy Company
SUNTREK INDUSTRIES
5 HOLLAND #215
IRVINE, CA 92618
C-46 LIC. #859460
(949) 348-9276
PROJECT
POOL THERMAL/
SHW SYSTEM
W
%U
�i
W
U)
W
LOCATION
Q
CO 0)
w�
oZ
o:D
0
0�
0
rn
w
2
W
W
Z
Q
2
J
O
tl
Q
J
O
U)
2
DESIGNER
A. HILL
IPT CONTROLLER
SPEC SHEET
REVISIONS
�A POOL SOLAR COLLECTOR DEPICTION
� SOLAR CONTROL
SHEET NO.
PT-3
s-
SRCCSearch Collector Record Detail
https://securedb.fsec.ucf.edu/srGc/coll-detail?srcc-ld=2005004A
SOLAR COLLECTOR CERTIFIED SOLAR COLLECTOR
CERTIFICATION AND RATING
Is L °R 9UPPLIEtt: Suntrek Industries, Inc.
5 Holland, Building 215
R CC Irvine, CA 92618 USA
e MODEL:
COLLECTOR TYPE: SunTrek Unglazed Flat -Plate
e SRCC OG-100 CERTIFICATIONM 2005004A
- .
ALL SIZES OF THIS COLLECTOR MODEL ARE CERTIFIED
COLLECTOR THERMAL
PERFORMANCE RATING
Megajoules Per Square Meter Per Day
Thousands of BTU Per Square Foot Per Day
CATEGORY
(Ti-Ta)
CLEAR
DAY
MILDLY
CLOUDY
I CLOUDY
DAY
CATEGORY
(Ti-Ta)
CLEAR
DAY
MILDLY
CLOUDY
CLOUDY
DAY
A (-5 °C)
19.7
15.7
11.8
A (-9 °F)
1.7
1.4
1.0
B (5 °C)
12.7
8.9
5.1
IB (9 °F)
1.1
0.8
0.4
C (20 °C)
5.5
2.2
0.0
C (36 °F)
0.5
0.2
0.0
D (50 °C)
0.0
0.0
0.0
ID (90 °F)
0.0
0.0
0
E (80 °C)
00
0.0
0.0
E (144 °F)
0.0
0.0
0.0
A- Pool Heating (Wane Climate) B- Pool Heating (Cool Climate) C- Water Heating (Warm Climate) D- Water Heating (Cool Climate) E-
Air Conditioning
Original Certification Date: 10-JUN-05
COLLECTOR SPECIFICATIONS
Gross Area:
Dry Weight:
Test Pressure:
3.869 m
2 41.64 ft 2 Net Aperature Area: 3.87 m2 41.64 ft2
213 kg 47. lb Fluid Capacity: 8.7 liter 2.3 gal
414. KPa 60. psig
COLLECTOR MATERIALS
Frame:
Cover (Outer):
Cover (Inner):
/
Absorber Material: Tube - EPDMPlate - None
Absorber Coating: None
TECHNICAL INFORMATION
Pressure Drop
None Flow AP
None mills gpm Pa in HZO
None
Insulation Side: None
Insulation Back: None
Efficiency Equation (NOTE: Based on gross area and (P)--PI-Tal
Y INTERCEPT
SLOPE
S I UNITS: rl= 0,856-17.93390 (P)/I
0.03856 (P)2/I
0.860
-17.678 Wlm2 °C
I P UNITS: rl= 0.856-3.15906 (P)/I
0.00377 (P)2/1
0.860
-3.114 BWhr ft2.°F
Incident Angle Modifier I(S)=I/cos0 -1, 01<0<=601]
Model Tested:
SunTrek
KTu = 1 -0.083 (S) 0.059 (S)2
Test Fluid:
Water
Kta = 1 -0.03 (S) Linear Fit
Test Flow Rate:
70.1 ml /s.m2
0.1032 gpm/ft2
REMARKS: Tests conducted outdoors.
Technical Specifications for Suntrek Solar Pool Collectors
SUNTREK
Collector:Extruded Ethylene Propylene Diene Monomer (EPDM) elastomer extrusion Your S olar Energy Company
Water channel: ID = .190, OD = .333" Weight: 1 lb. per square foot dry, 1.5 lb. per square foot wet
Manifold: Polypropylene; 2"in diameter, 72 channels
Maximum operating temperature: 1601
Maximum operating pressure:40 psi
BTU rating:1024 sqft/day
Optimum flow rate:1 gpm per 0.1 sgft
1 sq. foot Volumetric capacity= .053 +/- 2% US Gallons (.201 +/- 2% Liters)
Made in the USA
US Patent #: Des. 420,420
Head Loss:.008'persgft @ .1gpm per sqft
6.0"
.1901,L L�.jk AOL ALAML A11iLj1&,"LML
.333" Jam"
EPDM Elastomer Water Channels
28"
24"
_... ....... .......
/� .............
. •• . ..........I ..... ....
sGrJraec 5.2 2? 375"
One Piece Polypropylene Manifold
CITY Ok LA QUIN
NSF-50 Approved BILD1� WED FOR
CODE
COMPLIANCE
NSFIANSI SleiMad ra
Engineered for maximum performance, Suntrek solar pool heaters ark Igned ungi _U im ' ow
water channels. this innovative design improves the transformation of�ar energy into thermal energy for heating
your pool water. The material used for the Suntrek thermal heater is EPDM elastomer, which under normal operating
conditions will have a useful life of more than 20 years. The Suntrek heater becomes virtually a permanent part of
your pool and adds considerable value to your home or business. ,
Corporate Headquarters: 5 Holland #215 Irvine, CA 92618 (949) 348-9276 Fax (949) 348-1626
'OLAR COLLECTOR & MANIFOLD DETAIL
www.suntreksolar.com
S(0`ss`�
UNTREK
Your Solar Energy Company
SUNTREK INDUSTRIES
5 HOLLAND #215
IRVINE, CA 92618
C-46 LIC. #859460
(949) 348-9276
PROJECT
POOL THERMAL/
SHW SYSTEM
LOCATION
2
W LU
U �
Z Q cn
W (D
�� Z
co
W LU t- _
0j J
20< 0
17
Q0 Q
10-
J
U) O
DESIGNER
A. HILL
PT COLLECTOR
SPEC SHEETS
REVISIONS
SHEET NO.
PT-4