Loading...
BWFE2019-021678-495 CALLE TAMPICO D "'ill LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Permit Type/Subtype: WALL/FENCE/CITY STANDARD/PRE-APPROVED Application Number: BWFE2019-0216 Property Address: 77234 CASA DEL SOL APN: 773360002 Application Description: GERVAIS / PROPERTY BLOCK WALLS Property Zoning: Application Valuation: $7,000.00 Applicant: DCORONEL ENTERPRISES INC 42760 MADIO STREET OCT z 5 20t9 INDIO, CA 92201 nD CITY OF !A QUINTA DESIGN & DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.; Date:�10 Contractor: [CO OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Na Lender's Add VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/25/2019 Owner: GT LLC. 4776 WEST MILL RIVER COURT COEUR D'ALENE, ID 83814 Contractor: CORONEL ENTERPRISES INC 42760 MADIO STREET INDIO, CA 92201 (760)775-1234 Llc. No.: 727199 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of t r which this permit is issued. $ wo have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: IEN+ HMARX INSURANCE COMPANY Policy Number:SST5014903 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become sub t to the workers' compensation provisions of Se 'on 370 of the L Zir Code, sha forthwith comply with those provisions. Date: [� _)-S `11 Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state layis relatl q0 uildin construction, and hereby authorize representatives oft city t enter ❑n t e abov mentioned property for inspection purposes. Date: lv Signature (Applicant or Agent, �. DESCRIPTION ACCOUNT CITY AMOUNT RETAINING/COMBINATION WALL EA 501-F 101-0000-42400 0 $64.40 DESCRIPTION ACCOUNT QTY AMOUNT WALL/FENCE - EA ADDITIONAL 50LF 101-0000-42404 0 $64.40 DESCRIPTION ACCOUNT QTY AMOUNT WALL/FENCE - FIRST 100LF 101-0000-42404 0 $53.67 DESCRIPTION ACCOUNT QTY AMOUNT WALL/FENCE - FIRST 100LF PC 101-0000-42600 0 $67.08 Total Paid for BLOCK WALL 2019: $249.55 DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 za Qall�tra - GE,M .y":hr DESERT - PERMIT # U F O PLAN LOCATION: - Project Address: `-/ -7 3 �, \ \ Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: Applicant Name: Address: `( a� 6 v o % L LN-- G _ City, ST, Zip: hone:o IV1.0 : t Valuation of Project $ Contractor Name: New SFD Construction: Address: Q J Conditioned Space SF City, St, Zip \�,, LA 1 DL Garage SF Telephone: •76,0 ` 13 Patio/Porch SF Email: C�a.a er C_O Fire Sprinklers SF State Lic:`-7A--� �- City Bus Lic:. Arch/Eng Name: Construction Type: Occupancy: Grading: Address: City, St, Zip Telephone: Bedrooms: Stories: # Units: Email: State Lic: City Bus Lic: Property Owner's Name: New Commercial / Tenant Improvements: Address: �A Nk r Total Building SF City, ST, Zip Construction Type: Occupancy: Telephone: Email: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 k ORCO Z--0" TO Y--0" RETAINING WALL W/LEVEL BACKFILL SPECIAL INSPEC770N NOTE: TTE7j�A PER THE 2d16 CBC: PRQVIpE LEVEL B SPECL41 INSPECTION PER TMS AM PREOURE - ISM pSF 402-13/ACI530-13/ASCE 6.13 TABLE 3.1.2 OF THE LENT FLUID PRESSURE 63 ACE. MASONRY STEM PRIOR TO GROUTING TO VERIFY GR4pE BLE LATERAL PASSIVE PRESSURE = 150 PCF 7REINFORZING SIZE AND PROPER PLACEMENT OF REINFQRCEMENTAND STRENGTH - 2000 PSI @ 28 DAYS. TO ENSURE THE GROUT SPACE IS THE PROPER SIZE WITHOUT RCING STEEL :GRADE 60. I MASONRY COMPRESSION STRENGTH. OBSTRUCTION OTHER THANNORMAL MORTAR FUNS. (f1 S'AtU5•yAIiM MI L�srwrNCAsxnara Tq RROTECTMPLA[L� 2'-0"MIN. LEVEL mcr u .I4 HORZ COME [COMPACTED TO MIN 9" ATTOP REM ME COMPACTION PER ASTM 1557-0 p� '[DOWEL ®EDGEOFR"CNU ����6777F WATERPROOF MCKS1DE Z' C1R OF RETAINING WALL W/ X z� ORP WATERSTM 4'D& SOR7SIEA°PNL` Wj' 1 Cf. 1/116xA9 • ROPE TD UR AE OR INSTALL WEEP HOLES. M F4HORZ. L @I2'000NT.CONT.Z'O/C 'D'&R A' 12' tl 6 NOTE: DIMENSIONSARE NOT TO SCALE NOTES: 1. CONCXCTE BL04X SHALL BE ORCO MANUFACTURED WHIL7i CONFORMS TY7 ASTM C 90, W60GELOCK BLOCK, SLUMP BLOCK AND SPLITFACEBLQCKAREACCEPTABLE 2. CONCRETE FOR FOO77N6 SHALL BE I PART CEMENT TO 2412 PARTS SAND 703.112 PAR M GRAVEL WITH A M4XIMUA1 OF I-112 GALLONSOFWATER PERSAO'L PM7LINIDCEMENTSHALL CONFORM TO AST74 C 150 TYPE 111V. Fc = 2500 PSI 3, REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. RESIR5HALLBECENTEREDINTHE CONCRETE BL0CKCELL IN WHICH IT IS LDCATT'D. 5. CONCRETE BLOCK SHALL BE LAYED IN A RUNNING BOND PATTERN WITH VERTTC4L CONT7NUITY OF THE CELLS UNO. 6, ALL BLOCK CELLS SHALL BE SOLID GROUTED. 7. USE TYPES MORTAR PROPOR77ONED USING ASTM C 270 PART CEMENT TO 112 PART LIME TO 4-112 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE I PART CEMENT TD 3 PARTS S4ND (GROUT MAY CONTAIN 2 PARTS 318" FFA GRAVEL IF WEATHER CMDMT W ARE FAVORM$lEAND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BEADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATTON OF THE CONSTMENTS. 9. BLOCK STEM AMYBEWET-SET1-112"INTOTHEFOOTINGWHILE THE CONCRETE IS PLASTIC BLOCKSTEM MAYBE PLACED TO EITHER EDGE OF THE TRENCH TYPE F0077NG 10. F007ING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. ll. FIRST INSPEC77ON TO BEAFTER FOOTING TRENCHES ARE READY FOR CONCRETEAND ALL REQUIRED STEEL IS 77ED IN PLACE SECOND INSPEC77ON TO BE WHEN THE REQUIRED VER77CAL IS IN PLACEAND THEBLOCK WALL IS RE4DYTO GROUT. 12. MAXIMUM CONTROL JOINT SPACING.' 20' 01C. 'HT' 'A' 'B' 'CDOWEL 'D' BAR 'K' 2"-0" 6" 2'-3" 1¢L4®32" 0/C II33" NIA 9.. 21'J 3"-0" 1'-0" 2'-9' 1{4016" PIC 45" #4016' 0/C 72" —117" 27J Com"try CITY OF LA QUrNTA 77234 C45A DEL SOL LA QUINTA, C4LIF0RNI4 ORCO WALL SYSTEM FORCES PER 2016 CBC CHAPTER 16 WIND FORCES TO WALLS PER ASCE 7-10 SECTION 29.4 ^ CHECK WIND FORCE CALCULATION FOR BASIC 85 MPH 8 95 MPH 5 SECOND GUST SPEED EXPOSURE C CONDITION USING ASCE 7-10 CHAPTER 29 WIND LOADS 8 USING SECTION 29.3.2 TO FIND THE 3 SEC. VELOCITY PRESSURE OH OH= 0,00256 Kz Kzr K0 Vz... (29.5-1), WHERE.' Kz = 0.57 FOR EXP B AND Kz = 0.85 FOR EXP C FROM TABLE 29.5-1: KZT = l.0 DEFAULT PER SECTION 26.8-1 8 KD = 0.85 FROM SECTION 26.6-1 THEREFORE, FOR 85 MPH 8 95 MPH 5 SEC. WIND GUST SPEED: OR= (0.00256)(0.85)(1.0)(0.85)010)z = 22.4 PSF 8 OR =(0.00256)(0.85)(1.0)(0.85)(120)z = 26.6 PSF NOW USING SECTION 6.5.14 FOR SOLID FREESTANDING WALLS: FH= ON G CF AS.. (29.4-1), WHERE: G= a 85 FROM SECTION 26. 9.1 Cr = 1.40 PER FIGURE 29.4-1 USING AVERAGE ASPECT RATIO (WALL LENGTH TO HIGTH) OF 2. NOTE: CF RANGES FROM 1.48 FOR A 5' WIDE RETURN WALL TO 1.3 FOR A 60' PANEL. THEREFORE FOR Il0 MPH - (22.4 PSFO ASAQ A, = 16 7 PSF. 8 FOR l20 MPH = (ZO 6 PSF9O. *S10 41 A, - J1.7 PSF. WIND FORCE FOR EXPOSURE C CONDITIONS V,, IN MPH 100 /10 /20 130 1 /40 1.50 On = 0 00256 K, K,r V' I wneRe K,= 0 B5, K,.=40, Ho= 0 BS 1. 1&5 PSF 22.4 PSF 26 6 PSF 52.2 PSF 36. J PSF 416 PSF Fx = wimp FORCE PER S0. Ff. F„ = Ox G C, A, PER SECTION 20 4-1 22.0 PSf 26.7 PSF JL7 PSF JB. 4 PSF 412 PSF 4 9.5 PSF WHERE 6=0 85 AND C,= 14 APE. Fx =WIND FORCE BY USING 0. 60 LOAD 78 g$ 9J IOI IOB Ilb FACTOR PER CBC 1605 J. l EON /6-5 PROJECT SITE WIND ZONE- V ULT = ll ° MPH EXPOSURE C THEREFORE WIND FORCE = 24_-�- PSF ..<-- 63a��5 SEISMIC FORCES PER 2016 CBC (ASCE 7-10 SECT, 15.4.1e) YHOFL'Ssf CH FOR NONSU/LD/NG STRUCTURES: - FREE STANDING WALLS AND PILASTERS- - PROJECT SITE CLASS D - FUNDAMENTAL PERIOD T GREATER THAN 0. 06 SEC NO. 83660 ° ,* EA'P 0313111011 �. CALCULATED USING EQUATION 12.8-7 AND TABLE 12.8-2 �i p � 1 V 14 � ■ 4 ar CA00a PER EQN. 15.4-2, SEISMIC BASE SHEAR FOR FLEXIBLE NONBUILDING STRUCTURES NOT SIMILAR TO BUILDINGS. V= N.80)(S/)/(R/I)J W , WHERE 1 = I.0 8 FA = 1.1 FROM TABLE I1.4-1 6 R = J.0 FROM TABLE 15.4.2 SEISMIC FORCE FOR I SEC. PERIOD CONDITIONS S, FROM FIG. 12-2 60 1 70 1 80 1 90 /00 f 1/0 V = ((0.80)(S))/(R/0J W -1 0. 22w 0.24 w 0.25w 0.27W o. 30W - ! 0. 32W PROJECT SITE SEISMIC INFORMATION: S1 S V=o.?�-W f CMU WALL WEIGHTS PER SO. FT. BLOCK TYPE 6' CMU W/ JOINT REINFORCEMENT B' CMU 16XI6 PILASTER GROUTED 10/C 419'0/C 4010/C 32'O/C 24'0/C I6'0/C J2'O/C 24'0/C 16'O/C SOLID SOLID WT. PER S0, FT 34 PSF 55 PSF 37 PSF 39 PSF 45 PSF 48 PSF 52 PSF 60 PSF BO PSF 160 PSF THEREFORE SEISMIC FORCE IS: V 3 ::� PSF) _ 9 q PSF ORCO Block & Hardscape 11100 Beach Blvd Stanton, CA 90680 Tel. (714) 527-2239 This Wall in File: 0userMgvE drive - orco block compan Project Name/Number : city of la qu Title City pf La Quints Dsgnr: GV Description.... (01 a) 2':0" ret project files Page: 1 Date: 1 S OCT 2019 Ratampro (c) 1967.2010. Build n.1B.11aa Lloonae: KW.06059a01 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13 License. To ORCO BLOCK COMPANY, INC. Criteria Retained Height = 2.00 ft Wall height above soil = 6.00 ft Slope Behind Wall _ 0,00 Height of Soil over Toe = 6.00 in Water height over heel = 0.0 ft Surcharge Loads Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 Ibs Axial Live Load = 0.01bs Axial Load Eccentricity= 0.0 In Design Summar Wall Stability Ratios Overturning n 1.54 OK Sliding = 1.55 OK Total Bearing Load _ 949 Ibs ...resultant ecc. = 7.62 in Soil Pressure @ Toe = 1,292 psf OK Soil Pressure @ Heel = 0 psf OK Allowable - 1,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 1,808 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 7.5 psi OK Footing Shear @ Heel = 0.7 psi OK Allowable = 75.0 psi Sliding Cafes Lateral Sliding Force = 379.6lbs less 100 % Passive Force = - 304.7 Ibs less 100% Friction Force = - 2B4.71bs Added Force Req'd = 0.0 Ibs OK ...,for 1.5 Stability = 0.0 Ibs OK Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing Load Factors Building Code CBC 2016,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 Soil Data f Allow Soil Beanng = 1,500.0 psf Equivalent Fluid Pressure Method Active Heel Pressure = 63-0 psf/ft Passive Pressure = 150.0 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction = 0.300 Soil height to ignore for passive pressure = 12.00 in Lateral Load Applied to Stem Lateral Load = 0.0 Oft ...Height to Top = 0.00 ft ...Height to Bottom = 0.00 ft Load Type = Wind (W) (Strength Level) Wind on Exposed Stem = 26,7 psf (Strength Level) I �I1 .i 1 Adjacent Footing Load Adjacent Fooling Load r 0.0lbs Footing Width 0.00 ft Eccentricity 0.00 in Wall to Ftg CL Dist 0.00 ft Footing Type Line Load Base Above/Below Soil at Back of Wall 0.0 ft Poisson's Ratio = 0.300 Stem Construction end Bottom Stem OK Stem OK Design Height Above Ftg ft. 2.00 0.00 Wall Material Above "HI" a Masonry Masonry Design Method a LRFD LRFD LRFD Thickness . 6.00 8.00 Reber Size # 4 # 4 Rebar Spacing 32.00 32.00 Rebar Placed at = Center Edge Design Data fb/FB + fa/Fa a 0.543 0.540 Total Force @ Section Service Level Ibs = Strength Level Ibs = 160.2 361.8 Moment,... Actual Service Level ft-#= Strength Level ft-# = 480.6 935.4 Moment,..,. Allowable 114= 884.2 1,727-9 Shear..... Actual Service Level psi = Strength Level psi = 9.1 4.0 Shear..... Allowable psi = 80.5 80.5 Anet (Masonry) in2 = 17.53 91.50 Rebar Depth 'd' in = 2.75 5.25 Masonry Data f'm psi = 2,000 2,000 Fy psi= 60,000 60,000 Solid Grouting No Yes Modular Ration' = 16.11 16.11 Wall Weight psf = 42.0 78.0 Equiv. Solid Thick. in = 3.90 7.60 4Ror essra�fi Masonry Block Type = Medium Weight a�n JERpVrp F Masonry Design Method Concrete Data f'c = psi =a LRFD ro n ON n 1 Fy psis NO 63660 * EXP 03/31/2021 9rF CiV ❑Ftt ; OF CAME Project Name/Number : city of Is qu ORCO Block & Hardscape Title City pf La Quints Page : 2 11100 Beach Blvd Dsgnr: GV Date: 18 OCT 2019 Stanton, CA 90680 Description.... Tel. (714) 527-2239 (01 a) 2'•0" ret This Wall in File: c luse+slgverdugolaneddve - orco block rompanyldoGumWtfslrFlalnpr0 prolecl files no lam Pro ieJ 1687.2018. atlihl 11.18.11.29 Licanse : KW06059401 License To . ORCO BLOCK COMPANY, INC. Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13 Footing Dimensions & Strengths Footing Design Results Toe Width - 1.58 ft Toe Heel Heel Width 0.67 Factored Pressure = 1,806 0 psi Total Footing Width 2.25 Mu': Upward = 1,452 0 ft-k Footing Thickness M 12.00 in Mu': Downward = 378 0 ft-# Mu: Design = 1,075 0 h-# Key Width 12.00 in Actual 1-Way Shear = 7.48 0,74 psi Key Depth 9.00 in Allow 1-Way Shear = 40.00 40.00 psi Key Distance from Toe m 0.50 it Toe Reinforcing = None Spec'd Pc = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd Min. As % 0.0014 Other Acceptable Sizes & Spacings Cover @ Top 2.00 @ Btm = 3.00 in Toe: Not req'd: Mu < phi'S'lambda'sgrt(f'c)'Sm Heel: Not req'd: Mu < phi'5'lambda'sgrt(f'c)'Sm Key: Not req'd: Mu < phi'5"lambda'sgrt(f'c)'Sm Min footing T&S reinf Area 0.45 in2 Min footing T&S reinf Area per foot 0.20 in2 M If one layer of horizontal bars: If two layers of horizontal bars: #4@ 11.90 in #40 23.81 in #5@ 18.45 in #5@ 36.90 in #6@ 26.19 in #6@ 52.38 in Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... ..,..RESISTING..... Force Distance Moment Force Distance Moment Item Ibs h it-# Ibs it ft-# Heel Active Pressure = 283.5 1.00 283.5 Soil Over Heel = 2.25 Surcharge over Heel = Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem = Load @ Stem Above Soil = 96.1 6.00 576.7 ' Axial Live Load on Stem = - Soil Over Toe = 91.0 0.79 72.0 Surcharge Over Toe = Total 379.6 O.T.M. 860.2 Stem Weight(s) = 408.0 1.86 760.9 Earth @ Stem Transitions= Footing Weighl = 337.5 1.12 379.6 Resisting/Overturning Ratio = 1.54 Key Weight = 112.5 1.00 112.5 Vertical Loads used for Soil Pressure = 949-0 Ibs Vert. Component = Total = 949.0 Ibs R.M.= 1,325.0 ' tidal live load NOT included in total displayed or used for overturning fe819tance, but is included for soil pre"wre calculation. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Too of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci PROF EsSroN Horizontal Dail @ Top of Wall (approximate only) 0.128 in �qa� V4ERotrGC lli(_1�1.itr_111r�tl;_.Iwll c_.�1i t.alr.: 111e_hri;;1 ;plill.0 iu Jncs_:juir^c_.iP�l!i{•�-Ilull,r�l lug. _Iri< D z . NO 93660 * EXP 03/31/2021 .0 9TE C l v i °ill Y OF CAI''F Project Name/Number : city of la qu ORCO Block & Hardscape Title City 91 La Quints Page: 1 11100 Beach Blvd Dsgnr: GV Date: 18 OCT 2019 Stanton, CA 90680 Description,.,. Tel. (714) 527-2239 (01b) 3'-0" ret This Wall in File: c:\users\gverdugo\onedrive - orco block company\documents\retainpro p(ojecl files Rot olnAro(c] too 7.2010. Build II.I a.11.29 Licunse: KW-05059401 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACi 530-13 License To: ORCO BLOCK COMPANY, INC. Criteria ! Soil Data Retained Height = 3 00 ft Allow Soil Bearing = 1,500.0 psf I Wall height above soil = 6.00 It Equivalent Fluid Pressure Method Active Heel Pressure . - 63.0 psf/ft Slope Behind Wall = 0.00 Height of Soil over Toe = 6,00 in = Water height over heel = 0.0 ft Passive Pressure = 150.0 psf/ft Soil Density, Heel = 115.00 pcf Soil Density, Toe = 115.00 pcf FootingIlSoil Friction ~ = 0.300 " Soil height to ignore for passive pressure = 12 00 in Surcharge Loads Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Design Summary Wall Stability Ratios Overturning = 1.61 OK Sliding = 1.55 OK Total Bearing Load = 1,231 Ibs ...resultant ecc. = 8.51 in Soil Pressure 0 Toe = 1,233 psf OK Soil Pressure ® Heel = 0 psf OK Allowable - 1,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 1,726 psf ACI Factored @ Heel = 0 psf Footing Shear ® Toe = 9.6 psi OK Footing Shear ® Heel = 0.7 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 600.1 Ibs less 100 % Passive Force =' - 563.0 Ibs less 100 % Friction Force = - 369.2 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 Stability = 0,0 Ibs OK Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing Load Factors Building Code CBC 2016,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 Lateral Load Applied to Stem Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom = 0.00 ft Load Type = Wlnd (W) (Strength Level) Wind on Exposed Stem = 26.7 psf (Strength Level) Stem Construction Design Height Above Ftg ft = Wall Material Above "Ht" _ Design Method = Thickness = Reber Size = Reber Spacing = Rebar Placed at = Design Data fb/FB +fa/Fa Total Force ® Section Service Level Ibs = Strength Level Ibs = Moment.... Actual Service Level ft-# = Strength Level ft-# = Moment..,..Allowable ft-#= Shear..... Actual Service Level psi = Strength Level psf = Shear.....Allowable psi = Anet(Masonry) In2= Reber Depth 'd' In = Masonry Data I'm psi = Fy psi = Solid Grouting = Modular Ration' Wall Weight psi= 2nd Slem OK 3.00 Masonry -RFD 6.00 # 4 32.00 Center 0.543 Adjacent Footing Load Adjacent Footing Load = 0.0lbs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Fig CL Dist - 0.00 ft Footing Type Line Load Base Above/Below Soil _ at Back of Wall - 0.0 ft Poisson's Ratio = 0.300 Bottom Slem OK 0.00 Masonry LRFD LRFD 8.00 # 4 16.00 Edge 0.419 160.2 613.8 480.6 1,414.E 884.2 3,368.0 9.1 6.7 80.5 60.5 17.53 91.50 2.75 5.25 2,000 2,000 60,000 60,000 No Yes 16.11 16.11 42.0 78.0 Equiv. Solid Thick. in= 3.90 7.60 tRdfESS/cNa Masonry Block Type = Medium Weight tic 4011ODCO r R Masonry Design Method = LRFD k~ Concrete Data I; m m Pc psl+ v m p D n . Fy PSI = NO 83660 * E%P 03/31/2021 sT CI \r Spy tp 09 ct'01 BLOCK CO., INC. Since 1946 ANGELUS BLOCK MASONRY FENCE WALL SYSTEM DESIGN CRITERIA: 1. DESIGN CRITERIA PER 2016 CBC 2. ALLOWABLE SOIL BEARING PRESSURE - 1500pef 3. ALLOWABLE SOIL PASSIVE PRESSURE - 150pcf 4. COEFFICIENT OF FRICTION m 0.25, COHESION = Opef 5. CANTILEVER ACTIVE = 30pcf 6. MASONRY COMPRESSIVE STRENGTH, rm = 1500psi, SPECIAL INSPECTION NOT REQUIRED PER CBC SECTION 1704.2, EXCEPTION 2, 'U' OCCUPANCY. 7. USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE PROJECT SPECIFIC SITE. NOTES: 1. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 GRADE 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER, CENTER VERTICAL BARS IN CELLS. 6' to 8' High Site Wall Eccentric Spread Footing C o 110mph (uit) Risk Category I 6' Wide CMU OPTIONAL WAL �6 S'CD. LAODI pS STU FOR JOINT REl1'IF I COURSE, AT F COURSE, AND 2. JOINT REINFORCEMENT ("LADDER" TYPE) SHALL BE COLD -DRAWN STEEL WIRE CONFORMING TO ASTM A951. PROVIDE MINIMUM 6 INCH LAP SPLICES. 6" WIDE 3. STRENGTH OF CONCRETE FOR FOOTINGS = 2500psi 0 2B DAYS, UNLESS GROUT CELLS OTHERWISE REQUIRED BY SOILS REPORT. w/ REINF. 4. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90, ANGELUS BLOCK PRECISION, SPLIT FACE, BURNISHED, OR SHOTBLAST, WITH OR WITHOUT MORTARLESS HEAD JOINTS (TONGUE -AND -GROOVE), OR ANGELUS BLOCK SLUMPSTONE SHALL BE USED. 5. MORTAR SHALL BE SPEC MIX TYPE S PRE13LENDED MASONRY MORTAR AS MANUFACTURED BY E-Z MIX INC., CONFORMING TO PROPORTIONS AND 'X' BARS PER REQUIREMENTS OF ASTM C270, OR SPEC MIX IWWR MASONRY MORTAR AS SCHEDULE MANUFACTURED BY E-Z MIX INC., CONFORMING TO PROPERTY CTR. OF WALL REQUIREMENTS OF ASTM C270. 6. GROUT SHALL CONFORM TO ASTM C476, WITH AN 8-11 INCH SLUMP, AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2000psi. 7. FIRST COURSE MAY BE WET -SET 1 1/2 INCHES MAX. WHILE CONCRETE OWLS. TO MAT IS PLASTIC. VERT. REINF. 1 24" MIN. 8. CONCRETE BLOCK SHALL BE LAID IN RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS. F.G. 9. VERTICAL CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF 40'-O"o.c. OR 20'-0"o.c. IF WALL IS TO BE STUCCO COATED OR MORTAR WASHED WET -SET FIRS 10. GROUT ALL CELLS WITH REINFORCEMENT. COURSE 11. INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL FOOTING REINFORCING IS TIED IN PLACE. B. AFTER VERTICAL 2-Y4 CONT.— REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT. E2. FOR TYPICAL FOOTING STEP AND DRAINAGE BLOCK -OUT DETAILS SEE DETAIL SHEET S-5.1. CONT. CONC. t3. DO NOT PLACE FOOTING WITHIN 5'-0' OF A SLOPE MA50013Y FENCE WALL SU(EDULE 'H' MAX. 'X' BARS B' MIN. 76" LONG CMU 16' LONG CMU 6'-0" 1 414G48"o.c. I 94054"o.c. 1 2'—ti" 6' 1 7-4" 1 N4032"o.c. I #4036"o.c. 1 3'-0" 1 3' I GHL !NC. t2U gas-3addic St. ( Co,; ­_A J17113 F 625 939 .59$ F 6,6 ?J8 i1485 ti . -�.ighl o;m CITY OF LA QUINTA BUILDING DIVISION APPROVED FOR CONSTRUCTION BY: A. ,,,DATE: 04/27/2017 VLK SiCNLUULL r1o` 858�31 �; �c EXP. 9-30-18 OF CA��F% DATE SIGNED 4-12-17 S-1.1LQ #16-077 0 w En V a d4 *5LOCKC�M. ANGELUS BLOCK MASONRY FENCE WALL SYSTEM DESIGN CRITERIA, 1. DESIGN CRITERIA PER 2016 CBC 2. ALLOWABLE SOIL BEARING PRESSURE = 1500psf 3, ALLOWABLE SOIL PASSIVE PRESSURE = 150pcf 4, COEFFICIENT OF FRICTION = 0.25, COHESION = Opsf 5. CANTILEVER ACTIVE = 30pc1 6. MASONRY COMPRESSIVE STRENGTH, f'm = 1500pol. SPECIAL INSPECTION NOT REQUIRED PER CBC SECTION 1704.2, EXCEPTION 2, 'U' OCCUPANCY. 7. USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE PROJECT SPECIFIC SITE. I. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615 GRADE 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24 INCHES, WHICHEVER IS GREATER. CENTER VERTICAL BARS IN CELLS. 2. JOINT REINFORCEMENT ("LADDERS TYPE) SHALL BE COLD -DRAWN STEEL WIRE CONFORMING TO ASTM A951. PROVIDE MINIMUM 6 INCH LAP SPLICES. 3. STRENGTH OF CONCRETE FOR FOOTINGS = 2500psi ® 28 DAYS, UNLESS OTHERWISE REQUIRED BY SOILS REPORT. 4, CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS BLOCK PRECISION, SPLIT FACE, BURNISHED, OR SHOTBLAST, WITH OR WITHOUT MORTARLESS HEAD JOINTS (TONGUE —AND —GROOVE), OR ANGELUS BLOCK SLUMPSTONE SHALL BE USED. 5. MORTAR SHALL 8E SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS MANUFACTURED BY E-2 MIX INC., CONFORMING TO PROPORTIONS AND REQUIREMENTS OF ASTM C270. OR SPEC MIX IWR MASONRY MORTAR AS MANUFACTURED BY E—Z Mix INC., CONFORMING TO PROPERTY REQUIREMENTS OF ASTM C270. 6. GROUT SHALL CONFORM TO ASTM C476, WITH AN 8-11 INCH SLUMP, AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2000ps1. 7. FIRST COURSE MAY BE WET -SET 1 1/2 INCHES MAX. WHILE CONCRETE IS PLASTIC. 8. CONCRETE BLOCK SHALL BE LAID IN RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS. 9. VERTICAL CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF 40'-O"o.c. OR 20'-0"o.c. IF WALL IS TO BE STUCCO COATED OR MORTAR WASHED 10. GROUT ALL CELLS WITH REINFORCEMENT. 11. INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL FOOTING REINFORCING IS TIED IN PLACE. B. AFTER VERTICAL REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT. 12. FOR TYPICAL FOOTING STEP AND DRAINAGE BLOCK -OUT DETAILS SEE DETAIL SHEET S-5.1. 13. DO NOT PLACE FOOTING WITHIN 5-0" OF A SLOPE MASONRY FENCE RETAINING WALL SCHEOULE .H. 'X' BARS Y BARS 'B' MIN. 'C' MIN. 16" LONG CMU 16" LONG CMU 2'-0" 4032"o.c. 4048"o.c. 2'-9 N A 2'-8" 4032"o.c. 44D48"o.c. S-0" N/A T-4' #4032"o.c. #4048"o.c. 3'-5" N/A 4'-0" #4032"o.c. 4048"o.c. J 3'-' GHL INC. • =, 259id ;i95 6' High Wall 2' to 4' Retaining Heel -in Footing C ® 110mph (uft.) Risk Category I 6'/8" Wide CMU OPTIONAL WALL CAP - 16 STD. LADDER TYPE #S STO FOR SLUMPSTONE) JOINT REINF_ AT TOP COURSE, - AT FIRST COURSE, AND 24"o.c. AT FENCE 6" WIDE (NOM.) CMU w/ 'Y' BARS PER SCHEDULE W CTR. OF WALL. GROUT CELLS w/ REINF. #4 HORIZ. 024",3.:, ® RETAINING 4"0 SDR 35 PERF. PIPE w/ 1c.f. 3/4" GRAVEL WRAPPED IN MIRAFI 140N FILTER FABRIC- - SLOPE TO DRAIN. WATERPROOF BACKSIDE OF RETAINING WALL 8" WIDE (NOM.) CMU FULLY GROUTED 'X' BARS PER SCHEDULE, LAP 24" MIN. F.G. - WET -SET FIRST COURSE #4 CONT #4 CONT. ® 12"o.c.— CONT. CONC. FTG. CONC. KEY LOADING 1. SEISMIC, 5% DAMPING ® 1 SECOND ACCELERATION Cs=0.33Wt. 2. FOUNDATION SIZES BASED ON MAXIMUM WIND OR SEISMIC LOADING. CITY OF LA QUINITA BUILDING DIVISION APPROVED FOR CONSTRUCTION BY: A. SATE: 04/27/2017 M 'H' + 12" DISTANCE TO EDGE OF NEAREST ADJACENT FOUNDATION o a rOPTIONAL CHAMFER BACKFILL- III WELL GRADED, CLEAN SANDS OR GRAVEL OR COMBINATION USC= GW,GP OR SW,SP 21" OUTSIDE FACE OF BLOCK TO o OF VERT = x U 0 o: a N " U Y 12„ I 12" 'B' MIN. PER SCHEDULE ,PROFLSS, t7 rq c NO. B5 81 m is EXP. 9-30-18 C .I V `�, y�x of c++�-�F�¢ DATE SIGNED 4-12-17 S-1.6LQ #16-077 GENERAL INFORMATION AREA TABULATIONS OWNER: GREG & TERRI GERVAIS RESIDENCE 3,353 SO. FT. LOT 2, CASA DEL SOL GARAGE I MECHANICAL 1,139 50. FT. LA QUINTA, CA 92253 COVERED PATIO 986 SQ. FT LEGAL DESCRIPTION: LOT 2, TR 28409 TOTAL STRUCTURE 5,478 SQ FT APN: 773-360-002 TOTAL SITE 12,197 SQ. FT. 5,478 / 12,197 PROJECT ADDRESS: LOT 2, CASA DEL SOL TOTAL LOT COVERAGE 44.9% LA QUINTA, CA 92253 ' - - - ZONING. RM - RESIDENTIAL MEDIL • • • • OCCUPANCY: R-1 _ TYPE V-B NON -RATED L� 7 i 77i7 � L 3 R At.L RAVEL PA PIANTER I I I I I GRAVdL AC CONDENSER i SET ON TXT CONC. ) PAD TOP OF PAD TO 3•- —a BE NO LESS THAN 3' ABOVE GRADE (E) 6-0- HIGH BLOCK WALL CON I i WALK LOT 3 p� m ° } � GARAGE CONIC. q 1,139 SO FT WALK F.F. - 6570 F.G. - 65.20 IN13060 \ WROUGHT IRON GATE ^ (N) 6'-0' HIGH BLOCK WALL PV TV --- TEAR CREEK CHANNEL (E)6-0-HfGH BLOCK WALL IN28'0756-Ei ---- - (127.1T �V-V,5PLANTER PLANTER ±r.r Ir r1r�lrw� x t�.rn�.t'�r,���,L���r>A+�� ,r�.Lr..r►�.r.�►►,r,.�aa�.e.l•� t i "Y i -" :. ._...................... .. _._........... a a o . BBO COVERED PATIO CONC. DECK 726 SQ.FT. '% 2_3y :_:� \ LOT 2 RESIDENCE 3,353 SQ.FT. F.F. - 67 70 F.G•-67.20 z r PLANTER ---- i �, C VERED PA O I -- "� i77 SOFT, 11 P! PLA! I !! � CONIC. STEPS ❑ �A Li ON 65_ ...>> t 4' HIGH ILLUMINATEDPLANTER �- STREET NUMBERS •--ate ' VISIBLE AND LEGIBLE FROM THE STREET -__ - -64-- CONC STEPS � �} kk CONG. DRIVEWAY .... .. Z'I {i _ - CASA _ DEL � SOL A xTic .s S `i' «"� Ax),dtll 6[.G gWraoll- oil 6 THE DEVELOPER / CONTRACTOR / OWNER IS RESPONSIBLE FOR THE VERIFICATION OF EXISTING CURB (OR EDGE OF STREET PAVING IF NO CURB EXISTS) LOCATION FROM PROPERTY LINES) WITH THE PUBLIC WORKS DEPARTMENT. I I I � --- --- .._ _........... ... ...._. __...... ........... • I r�-jL� CONC.DECK I �r � I G{iAVEL r- I I 6-0- HIGH t � I BLOCK WALL p 1 I I r LOT 1 I 16'•�- II 4 SFtBACK Wi6'-0"HIGH BLOCK WALL I I I � ?-1 CONIC. ' •+�5 PATIO I I 1 OVERE-y.ATIO .. _ 83 SQ.FT. 0 - •... _ 1 I WROUGHT +� I IRON GATE � � I ( I ` CONC. PATIOXPOkl TER»1 � I I \\� J T .. SITE PLAN SCALE: 1/8" = V-0" I NORTH CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY 7 713 y CASA OEL 5*04,