Loading...
SBA 1994-249C.' C T-itit 4 4(4j Q" June 7, 1994 78-495 CALLE TAMPICO — LA OUINTA, CALIFORNIA 92253 - (619) 777-7000 FAX (619) 777-7101 Mr. A. P. Lench, II P.O. Box 450 La Quinta, CA 92253 SETBACK ADJUSTMENT: 94-249 LOCATION: 54-600 Avenida Ramirez Dear Skip: This letter is to report approval of your recent application for a setback adjustment, pursuant to Chapter 9.188 of the City of La Quinta Planning & Zoning regulations. The following setback adjustment has been approved subject to conditions and in accordance with attached Exhibit A. SETBACK ADJUSTMENT: Reduction of rear yard setback from 5 -feet to 3 -feet. JUN 0 8.1994 FOR: Pool/Spa CONDITIONS: BUILDING AND SAFETY 1. Obtain a building permit from the Building Department. 2. The fencing requirements of the S -R Zone shall be met. 3. The pool equipment shall be located 5 -feet from the side property line 4. A three inch (3) PVC conduit, schedule 40 or better, shall be placed within the public utility easement in your rear yard area. This would facilitate accessing the area in the future, should the need to replace public utility facilities arise. 'This conduit is to be capped off within five feet (5) of the side property lines, and should be placed at a maximum depth of thirty inches (30). After review it was determined that: 1. This adjustment is consistent with the intent and purpose of the Zoning Ordinance. 2. There are special circumstances applicable to the property, including such factors as size, shape, topography, location or surroundings that justify approval of the adjustment. These special circumstances are: small size of lot. 3. This adjustment will not be detrimental to the health, safety, and general welfare of the community or be detrimental to roperty in the vicinity of the �J parch'` bP(klARRadjWtA YA iL5%(jUb4te0CVj TA, CALIFORNIA 92253 LTRGT.23a S r If you should have any questions, please contact the undersigned. Very truly yours, JE MAN P TNI GJAND DEVELOPMENT DIRECTOR L � �Y 4qE- "T-ROUSDELL Associate Planner GT: kaf Attachment c Buiilding-and-Safety Department ) LTRGT.234 I EXISTING HOUSE r ON 3SdO ilTHX3 Va A/c = i - - 1N3WIUVd301N3Wd013A3019PJIIJNVId .063 ddV 5'-0" , SPA RAISED !' oo �. _.� STEP. • ST EPS - RTY i / 6'-6 WATER RETURN ' r-- - P L E UIP lEtL SKIMMER' DRAIIW PROPERTY LINE .. •b � � _� -- -- - .P®OLS: � ��r�P ,ti •, ;. — r .f. i BENCH ` 6'FT.; TO 3'FT .DEEP; WATER RETURN L. S UCCO WALL BEAM I - - - . STUCCO WALL" - PROPERTY LINE SCALE. 1/4" LEGAL DESCRIPTION: LOT M BLOCK 306, JOB 112 ADDRESS: 51608 AVENIDA RAMIREZ FOOL DLBOGNED FOR&: : MS. LISA GOEBEL, Z...'�,..�•�ma � a",�-ter.; ti :; ,.. �N `