BRES2018-0065 Revision 1Contractor Name:
Address:
City, St, Zip
Telephone:
Email:
State Lic:
City Bus Lic:
Property Owner's Name:
Address:
City, ST, Zip
Telephone:
Email:
New SFD Construction:
Conditioned Space
Garage
Patio/Porch
Fire Sprinklers
SF
SF
SF
SF
�•t - New Commercial / Tenant Improvements:
Total Building SF
Construction Type: Occupancy:
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
OFFICE USE ONLY
# Submittal Required Received
Plan Sets
Structural Calcs
Truss Calcs
Title 24 Calcs
i Soils Report
Grading Plan (PM10)
Landscape Plan
Subcontractor List
Grant Deed
HOA Approval
School Fees
M
Debris Tian
approval
orks approval
Fire approval
City Business License
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Williams Residence Calculation Date/Time: 16:15, Fri, Jun 14, 2019
Calculation Description: Title 24 Analysis
Input File Name: Williams Res Lot 17D-17 (1).ribdl6x
CF1 R-PRF-01
Page 1 of 12
GENERAL INFORMATION
01
Project Name
Williams Residence
02
Calculation Description
Title 24 Analysis
03
Project Location
80886 Via Pessaro
04
City
La Quinta
05 Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.3.1 (1149)
08
Climate Zone
CZ15
Software Version
EnergyPro 7.2
10
Building Type
Single Family
11 Front Orientation (deg/Cardinal)
100
12
Project Scope
Newly Constru
tr-�n9
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft2)
4888
CITY OF LA
Number of Zones
4
16
Slab Area (ft2)
3934ESUILTANU
Number of Stories
2
18
Addition Cond. Floor Area(ft2)
n/a
r, Natural Gas Available
Yes
20
Addition Slab Area (ft2)
n/a
Glazing Percentage (%)
26.3%
COMPLIANCE RESULTS
IFE
C3rCC-
01
Building Complies with Computer Performanc
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
1 This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
3.25
6.63
-3.38
-104.0%
Space Cooling
89.40
82.65
6.75
7.6%
IAQ Ventilation
0.88
0.88
0.00
0.0%
Water Heating
3.36
2.84
0.52
15.5%
Photovoltaic Offset
---
0.00
0.00
--
Compliance Energy Total
96.89
93.00
3.89
4.0%
Registration Number: 217-P010370072E-000-000-0000000-0000 Registration Dateffime: 2019-06-14 16:27:54 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-06-14 16:16:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Williams Residence Calculation Datefrime: 16:15, Fri, Jun 14, 2019
Calculation Description: Title 24 Analysis
Input File Name: Williams Res Lot 17131-17 (1).ribd16x
CFI R-PRF-01
Page 2 of 12
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency
EDR of Proposed Efficiency
EDR Value of Proposed PV + Battery Final Proposed EDR
50.9
49.2
0.0 49.2
❑
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV)
renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified.
Notes:
• Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering NEM rules
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High quality insulation installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Verified Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Low -leakage Air Handling Unit
Domestic Hot Water System Verifications:
• —None —
Registration Number: 217-P010370072E-000-000-0000000-0000 Registration Date/Time: 2019-06-14 16:27:54 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-06-14 16:16:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Williams Residence Calculation Date/Time: 16:15, Fri, Jun 14, 2019
Calculation Description: Title 24 Analysis
Input File Name: Williams Res Lot 17D-17 (1).ribd16x
CF1 R-PRF-01
Page 3 of 12
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ftZ)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Williams Residence
4888
1
5
4
0
1
ZONE INFORMATION
01 1
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ftz)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Casita
Conditioned
HVAC 41
950
10
DHW Sys 1
n/a
Bed 2,3
Conditioned
HVAC 32
1099
11
DHW Sys 1
n/a
Great Room
Conditioned
HVAC 23
1885
12
DHW Sys 1
n/a
Upstairs Master
Conditioned
HVAC 14
954
10
DHW Sys 1
n/a
Registration Number: 217-P010370072E-000-000-0000000-0000 Registration Dateffime: 2019-06-14 16:27:54 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-06-14 16:16:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Williams Residence Calculation Date/Time: 16:15, Fri, Jun 14, 2019
Calculation Description: Title 24 Analysis
Input File Name: Williams Res Lot 1713-17 (1).ribdl6x
CF1 R-PRF-01
Page 4 of 12
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ft2)
Tilt (deg)
10d Wall
Casita
R-21 Wall
10
Right
365
75.5
90
100d Wall
Casita
R-21 Wall
100
Front
435
43
90
190d Wall
Casita
R-21 Wall
190
Left
400
60.5
90
280d Wall
Casita
R-21 Wall
280
Back
405
88.5
90
325d Wall
Casita
R-21 Wall
325
- specify -
50
24
90
Interior Surface
Casita»Bed 2,3
R-0 Interior Wall
n/a
n/a
150
0
n/a
Roof
Casita
R-38 Roof Attic VENTED
n/a
n/a
950
n/a
n/a
10d Wall 2
Bed 2,3
R-21 Wall
10
Right
110
16.5
90
100d Wall 2
Bed 2,3
R-21 Wall
100
Front
235
33.5
90
190d Wall 2
Bed 2,3
R-21 Wall
190
Left
485
24
90
280d Wall 2
Bed 2,3
R-21 Wall
280
Back
475
58
90
Interior Surface 2
Bed 2,3>>Casita
R-0 Interior Wall
n/a
n/a
150
0
n/a
Interior Surface 3
Bed 2,3—Great Room
R-0 Interior Wall
n/a
n/a
440
0
n/a
Roof 2
Bed 2.3
R-38 Roof Attic VENTED
n/a
n/a
428
n/a
n/a
10d Wall 3
Great Room
R-21 Wall
10
Right
600
277.5
90
100d Wall 3
Great Room
R-21 Wall
100
Front
738
269.5
90
190d Wall 3
Great Room
R-21 Wall
190
Left
174
0
90
280d Wall 3
Great Room
R-21 Wall
280
Back
450
57
90
Interior Surface 4
Great Room»Bed 2,3
R-0 Interior Wall
n/a
n/a
440
0
n/a
Interior Surface 5
Great Room
R-0 Interior Wall
n/a
n/a
255
0
n/a
Roof 3
Great Room
R-38 Roof Attic VENTED
n/a
n/a
1390
n/a
n/a
10d Wall
Upstairs Master
R-21 Wall
10
Right
365
120
90
100d Wall 4
Upstairs Master
R-21 Wall
100
Front
423
26.5
90
190d Wall 4
Upstairs Master
R-21 Wall
190
Left
365
88.5
90
280d Wall 4
Upstairs Master
R-21 Wall
280
Back
423
48
90
Interior Surface 6
Upstairs Master»Bed 2,3
R-0 Interior Wall
n/a
n/a
255
0
n/a
Roof 4
Upstairs Master
R-38 Roof Attic VENTED
n/a
n/a
954
n/a
n/a
R19
Upstairs Master
R-19 Floor Crawlspace
n/a
n/a
954
n/a
n/a
Registration Number: 217-P010370072E-000-000-0000000-0000 Registration DateMme: 2019-06-14 16:27:54 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-06-14 16:16:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Williams Residence Calculation DatelTime: 16:15, Fri, Jun 14, 2019
Calculation Description: Title 24 Analysis
Input File Name: Williams Res Lot 17D-17 (1).ribd16x
CF1 R-PRF-01
Page 5 of 12
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Casita
Attic RoofCasita
Ventilated
3
0.1
0.85
Yes
No
Attic Bed 2,3
Attic RoofBed 2,3
Ventilated
0
0.1
0.85
Yes
No
Attic Great Room
Attic RoofGreat Room
Ventilated
0
0.1
0.85
Yes
No
Attic Upstairs Master
Attic RoofUpstairs Master
Ventilated
0
0.1
0.85
Yes
No
Registration Number: 217-P010370072E-000-000-0000000-0000 Registration DatelTme: 2019-06A416:27:54 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-06-14 16:16:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Williams Residence Calculation Date/Time: 16:15, Fri, Jun 14, 2019
Calculation Description: Title 24 Analysis
Input File Name: Williams Res Lot 1713-17 (1).ribd16x
CF1 R-PRF-01
Page 6 of 12
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft2)
U-factor
SHGC
Exterior Shading
17 - 6080FR
Window
10d Wall (Right-10)
--
-
1
48.0
0.51
0.26
Insect Screen (default)
21 - 5056CS
Window
10d Wall (Right-10)
-
1
27.5
0.59
0.17
Insect Screen (default)
22 - 2056CS
Window
100d Wall (Front-100)
1
11.0
0.60
0.17
Insect Screen (default)
23 - 2056CS
Window
100d Wall (Front-100)
-
--
1
11.0
0.60
0.17
Insect Screen (default)
24 - 2030CSfTG
Window
100d Wall (Front-100)
-
1
6.0
0.60
0.17
Insect Screen (default)
25 - 3050CS
Window
100d Wall (Front-100)
-
-
1
15.0
0.60
0.17
Insect Screen (default)
26 - 3056CS
Window
190d Wall (Left-190)
-
1
16.5
0.60
0.17
Insect Screen (default)
27 - 3056CS
Window
190d Wall (Left-190)
-
1
16.5
0.60
0.17
Insect Screen (default)
28 - 5056CS
Window
190d Wall (Left-190)
-
-
1
27.5
0.59
0.17
Insect Screen (default)
19 - 3056CS
Window
280d Wall (Back-280)
-
-
1
16.5
0.60
0.17
Insect Screen (default)
20 - 9080PD
Window
280d Wall (Back-280)
-
-
1
72.0
0.32
0.28
Insect Screen (default)
18 - 3080FR
Window
325d Wall (- specify -325)
---
-
1
24.0
0.51
0.26
Insect Screen (default)
15 - 3056CS
Window
10d Wall 2 (Right-10)
--
-
1
16.5
0.60
0.17
Insect Screen (default)
16 - 5056CS
Window
100d Wall 2 (Front-100)
--
--
1
27.5
0.59
0.17
Insect Screen (default)
14 - 2030CS
Window
100d Wall 2 (Front-100)
--
1
6.0
0.60
0.17
Insect Screen (default)
1 - 3080FR
Window
280d Wall 2 (Back-280)
-
-
1
24.0
0.51
0.26
Insect Screen (default)
2 - 3080FR
Window
280d Wall 2 (Back-280)
-
---
1
24.0
0.51
0.26
Insect Screen (default)
3 - 2050CS
Window
280d Wall 2 (Back-280)
-
-
1
10.0
0.60
0.17
Insect Screen (default)
7 - 10070 FGlrG
Window
10d Wall 3 (Right-10)
-
-
1
70.0
0.35
0.22
Insect Screen (default)
9 - 8650 BI-FOLD
Window
10d Wall 3 (Right-10)
8.5
5.0
1
42.5
0.37
0.23
Insect Screen (default)
11 - 16.5X10 PSGD
Window
10d Wall 3 (Right-10)
16.5
10.0
1
165.0
0.37
0.23
Insect Screen (default)
12-16.5X10 PSGD
Window
100d Wall 3 (Front-100)
16.5
10.0
1
165.0
0.37
0.23
Insect Screen (default)
13 - PR3080FR
Window
100d Wall 3 (Front-100)
-
-
1
48.0
0.51
0.26
Insect Screen (default)
8 - 3080FR
Window
100d Wall 3 (Front-100)
3.0
8.0
1
24.0
0.51
0.26
Insect Screen (default)
10 - 6650 BI-FOLD
Window
100d Wall 3 (Front-100)
---
-
1
32.5
0.38
0.23
Insect Screen (default)
4 - 3080FR
Window
280d Wall 3 (Back-280)
-
1
24.0
0.51
0.26
Insect Screen (default)
5 - 3056CS
Window
280d Wall 3 (Back-280)
--
1
16.5
0.60
0.17
Insect Screen (default)
6 - 3056CS
Window
280d Wall 3 (Back-280)
--
1
16.5
0.60
0.17
Insect Screen (default)
33 - 12080 PD
Window
10d Wall 4 (Right-10)
-
---
1
96.0
0.32
0.28
Insect Screen (default)
Registration Number: 217-Po10370072E-000-000-0000000-0000 Registration DateRme: 2019-06-14 16:27:54 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-06-14 16:16:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Williams Residence Calculation Date/Time: 16:15, Fri, Jun 14, 2019
Calculation Description: Title 24 Analysis
Input File Name: Williams Res Lot 1713-17 (1).ribdl6x
CF1 R-PRF-01
Page 7 of 12
34 - 2040FG
Window
10d Wall 4 (Right-10)
1
8.0
0.35
0.22
Insect Screen (default)
35 - 2040FG
Window
10d Wall 4 (Right-10)-
-
1
8.0
0.35
0.22
Insect Screen (default)
36 - 2040FG
Window
10d Wall 4 (Right-1 0)
- -
-
1
8.0
0.35
0.22
Insect Screen (default)
37 - 3056FG
Window
100d Wall 4 (Front-100)
-
--
1
16.5
0.35
0.22
Insect Screen (default)
41 - 2050CS
Window
100d Wall 4 (Front-100)
--
--
1
10.0
0.60
0.17
Insect Screen (default)
38 - 2040FG
Window
190d Wall 4 (Left-190)
-
1
8.0
0.35
0.22
Insect Screen (default)
39 - 2040FG
Window
190d Wall 4 (Left-190)
-
--
1
8.0
0.35
0.22
Insect Screen (default)
40 - 2040FG
Window
190d Wall 4 (Left-190)
--
-
1
8.0
0.35
0.22
Insect Screen (default)
42 - 3080FR
Window
190d Wall 4 (Left-190)
-
-
1
24.0
0.51
0.26
Insect Screen (default)
43 - 3056FR
Window
190d Wall 4 (Left-190)
--
-
1
16.5
0.60
0.17
Insect Screen (default)
44 - 3080FR
Window
190d Wall 4 (Left-190)
-
1
24.0
0.51
0.26
Insect Screen (default)
29 - 2050CS
Window
280d Wall 4 (Back-280)
-
-
1
9.0
0.51
0.26
Insect Screen (default)
30 - 2030CS
Window
280d Wall 4 (Back-280)
--
1
6.0
0.60
0.17
Insect Screen (default)
31 - 3056CS
Window
280d Wall 4 (Back-280)
-
-
1
16.5
0.60
0.17
Insect Screen (default)
32 - 3056CS
Window
280d Wall 4 (Back-280)
-
-
1
16.5
0.60
0.17
Insect Screen (default)
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (ft2)
U-factor
3080SC
190d Wall 2
24.0
0.50
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right
Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
9- 8650 BI-FOLD
8
0.1
8
8
0
0
0
0
0
0
0
0
0
11 - 16.5X10 PSGD
8
0.1
8
8
0
0
0
0
0
0
0
0
0
12 - 16.5X10 PSGD
12
0.1
12
12
0
0
0
0
0
0
0
1 0
0
8- 3080FR
12
0.1
12
12
0
0
0
0
0
0
0
0
0
Registration Number: 217-P010370072E-000-000-0000000-0000 Registration DateRme: 2019-06-14 16:27:54 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-06-14 16:16:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Williams Residence Calculation Date/Time: 16:15, Fri, Jun 14, 2019
Calculation Description: Title 24 Analysis
Input File Name: Williams Res Lot 17D-17 (1).ribdl6x
CF1 R-PRF-01
Page 8 of 12
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
Rvalue
U-factor
Assembly Layers
• Around Roof Joists. R-6.0 insul.
• Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
• Roof Deck. Wood Siding/sheathing/decking
Attic RoofCasita
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 19
0.059
• Roofing. Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
• Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic VENTED
attic)
Wood Framed Ceiling i
2x4 @ 16 in. O.C.
R 38
0.025
- Over Ceiling Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
R-21 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.069
• Exterior Finish: 3 Coat Stucco
• Inside Finish: Gypsum Board
• Cavity/Frame: no insul. /2x4
R-0 Interior Wall
Interior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
none
0.277
• Other Side Finish: Gypsum Board
• Around Roof Joists: R-6.0 insul.
• Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
• Roof Deck. Wood Siding/sheathing/decking
Attic RoofBed 2,3
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 19
0.059
• Roofing. Light Roof (Asphalt Shingle)
• Around Roof Joists: R-6.0 insul.
• Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
• Roof Deck: Wood Siding/sheathing/decking
Attic RoofGreat Room
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 19
0.059
• Roofing: Light Roof (Asphalt Shingle)
• Around Roof Joists. R-6.0 insul.
- Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
• Roof Deck: Wood Siding/sheathing/decking
Attic RoofUpstairs Master
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 19
0.059
• Roofing: Light Roof (Asphalt Shingle)
• Floor Surface: Carpeted
Floors Over
R 19 in 5-1/2 in.
Floor Deck: Wood Siding/sheathing/decking
R-19 Floor Crawlspace
Crawlspace
Wood Framed Floor
2x6 @ 16 in. O.C.
cavity (R-18)
0.050
Cavity/Frame: R-19 in 5-1/2 in. (R-18) /2x6
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R value & Depth
Carpeted Fraction
Heated
Slab -on -Grade
Casita
950
170
None
0.8
No
Slab -on -Grade 2
Bed 2,3
1099
190
None
0.8
No
Slab -on -Grade 3
Great Room
1885
225
None
0.8
No
Registration Number: 217-P010370072E-000-000-0000000-0000 Registration DateMme: 2019-06-14 16:27:54 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-06-14 16:16:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Williams Residence Calculation Date/Time: 16:15, Fri, Jun 14, 2019
Calculation Description: Title 24 Analysis
Input File Name: Williams Res Lot 17D-17 (1).ribdl6x
CF1 R-PRF-01
Page 9 of 12
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
n/a
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Standard
DHW Heater 1 (3)
3
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Input Rating I
Tank
Standby
Heater
Tank
Uniform Energy
Pilot /
Insulation
Loss /
First Hour
NEEA Heat Pump
Tank Location
Element
Number
Volume
Factor / Energy
Thermal
R-value
Recovery
Rating /
Brand / Model 1
or Ambient
Name
Type
Tank Type
of Units
(gal)
Factor / Efficiency
Efficiency
(Int/Ext)
Eff
Flow Rate
Other
Condition
DHW Heater 1
Gas
Small
3
0
0.97 EF
<= 200 kBtu/hr
R-0/R-0
0
n/a
n/a
n/a
Instantaneous
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC 41
Other Heating and Cooling
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
System
HVAC 32
Other Heating and Cooling
Heating Component 2
Cooling Component 2
HVAC Fan 2
Air Distribution System 2
System
HVAC 23
Other Heating and Cooling
Heating Component 3
Cooling Component 3
HVAC Fan 3
Air Distribution System 3
System
HVAC 14
Other Heating and Cooling
Heating Component 4
Cooling Component 4
HVAC Fan 4
Air Distribution System 4
System
HVAC - HEATING UNIT TYPES
01
02
03
04
Name
System Type
Number of Units
Efficiency
Heating Component 1
CntrlFumace
1
80 AFUE
Heating Component 2
CntrlFumace
1
80 AFUE
Heating Component 3
CntrlFumace
2
80 AFUE
Heating Component 4
CntrlFumace
1
80 AFUE
Registration Number: 217-P010370072E-000-000-0000000-0000 Registration Date/Time: 2019-06-14 16:27:54 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-06-14 16:16:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Williams Residence Calculation DatelTime: 16:15, Fri, Jun 14, 2019
Calculation Description: Title 24 Analysis
Input File Name: Williams Res Lot 1713-17 (1).ribd16x
CFI R-PRF-01
Page 10 of 12
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
08
Efficiency
Name
System Type
Number of Units
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
1
13
16
Not Zonal
Single Speed
Cooling Component
1-hers-cool
Cooling Component 2
SplitAiiCond
1
13
16
Not Zonal
Single Speed
Cooling Component
2-hers-cool
Cooling Component 3
SplitAirCond
2
13
16
Not Zonal
Single Speed
Cooling Component
3-hers-cool
Cooling Component 4
SplitAirCond
1
13
16
Not Zonal
Single Speed
Cooling Component
4-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
Cooling Component 2-hers-cool
Required
350
Required
Required
Required
Cooling Component 3-hers-cool
Required
350
Required
Required
Required
Cooling Component 4-hers-cool
Required
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Specified Lower Leakage
8
Attic
None
Air Distribution System
Target
1-hers-dist
Air Distribution System 2
DuctsAttic
Specified Lower Leakage
8
Attic
None
Air Distribution System
Target
2-hers-dist
Air Distribution System 3
DuctsAttic
Specified Lower Leakage
8
Attic
None
Air Distribution System
Target
3-hers-dist
Air Distribution System 4
DuctsAttic
Specified Lower Leakage
8
Attic
None
Air Disfibution System
Target
4-hers-list
Registration Number: P17-P010370072E-000-000-0000000-0000 Registration DateRme: 2019-06-1416:27:54 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-06-14 16:16:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Williams Residence Calculation Date/Time: 16:15, Fri, Jun 14, 2019
Calculation Description: Title 24 Analysis
Input File Name: Williams Res Lot 17D-17 (1).ribd16x
CFI R-PRF-01
Page 11 of 12
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
Required
Air Distribution System 2-hers-dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
Required
Air Distribution System 3-hers-dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
Required
Air Distribution System 4-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
Required
HVAC-FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1-hers-fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.58
HVAC Fan 2-hers-fan
HVAC Fan 3
Single Speed PSC Furnace Fan
0.58
HVAC Fan 3-hers-fan
HVAC Fan 4
Single Speed PSC Furnace Fan
0.58
HVAC Fan 4-hers-fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.58
HVAC Fan 2-hers-fan
Required
0.58
HVAC Fan 3-hers-fan
Required
0.58
HVAC Fan 4-hers-fan
Required
0.58
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
94
0.25
Default
0
Required
Registration Number: 217-P010370072E-000-000-0000000-0000 Registration DateMme: 2019-06-14 16:27:54 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-06-14 16:16:31
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Williams Residence Calculation Date/Time: 16:15, Fri, Jun 14, 2019
Calculation Description: Title 24 Analysis
Input File Name: Williams Res Lot 17D-17 (1).ribdl6x
CF1 R-PRF-01
Page 12 of 12
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
7;ri-'7e0z `
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2019-06-14 16:27:54
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
r6wel5cw
Tim Scott
Company:
Date Signed:
Scott Design and Title 24, Inc.
2019-06-14 16:27:54
Address:
License:
77085 Michigan Drive
NA
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration
Provider responsibility for the accuracy of the information.
0
Easy to Verify
at CaICERTS.com
Registration Number: 217-P010370072E-000-000-0000000-0000 Registration Date/Time: 2019-06-14 16:27:54 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-06-14 16:16:31