Loading...
BRES2018-0255 Revision 1r►ry mi cc& CALIFORNIA PERMIT # PLAN LOCATION: Project Address: �� ��0?� �4uv�t�� Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: Z.- Applicant Name: dC��►� Address: y YC�tJV,k City, ST, Zip: Telephone: Email: Valuation of Project $ Contractor Name: a-0-4 L,3 (fe) ws New SFD Construction: Address: (� lsk lGWCL4 Conditioned Space SF City, St, Zip .-, Garage SF Telephone: 7� 0 f. r�7S Patio/Porch SF Email: V" 1 1� Fire Sprinklers SF State Lic: City Bus Lic: Arch/Eng Name: Construction Type: Occupancy: Address: Grading: City, St, Zip -1 Bedrooms: Stories: # Units: Telephone: Email: State Lic: City Bus Lic: Property Owner's Name: ~� �GiC New Commercial / Tenant Improvements: Address: Total Building SF City, ST, Zip Construction Type: Occupancy: Telephone: Email: 78495 CALLE TAMPICO LA QUINTA, CA 92253 (760)777-7125 W W W. LAQU I N TACA. GOV OFFICE USE ONLY # Submittal Req'd Req'd Plan Sets Structural Calcs Truss Calcs Title 24 Calcs Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License A CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Wallace Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 07:06, Wed, Nov 13, 2019 Input File Name: Wallace Residence.ribd16x CFI R-PRF-01 Page 1 of 21 GENERAL INFORMATION 01 Project Name Wallace Residence 02 Calculation Description Title 24 Analysis 03 Project Location 81-303 Columbus Way Madison Club 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 0 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 10517 15 Number of Zones 10 16 Slab Area (ft2) 8817 17 Number of Stories 2 18 Addition Cond. Floor Area(ft2) n/a 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) n/a 21 I to 8 COMPLIANCE RESULTS 01 Building Complies with Computer Performance _' ' ' %0' L-" %9 V 11 Y 1 h 02 This building incorporates features that require field testing and/or verification by a certified I ER ]��pro d HERS provider.. 03 This building incorporates one or more Special Features shown below I FOR CONSTRUCTION I rrt ENERGY USE SUMMARY oa 05 os 1 DATI I13Y 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin rcent Improvement Space Heating 5.58 5.09 0.49 8.8% Space Cooling 96.57 93.44 3.13 3.2% IAQ Ventilation 0.69 0.69 0.00 0.0% Water Heating 1.56 1.49 007 4.5% Photovoltaic Offset ---- 0.00 0.00 -- Compliance Energy Total 104.40 100.71 3.69 3.5% �RE52o18-0255 Registration Number: 219-P010241011A-000-000-0000000-0000 Registration Date/Time: 2019-11-13 07:21:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-11-13 07:09:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Wallace Residence Calculation Date/Time: 07:06, Wed, Nov 13, 2019 Calculation Description: Title 24 Analysis Input File Name: Wallace Residence.ribd16x CFI R-PRF-01 Page 2 of 21 ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR 44.0 42.6 0.0 42.6 ❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified. Notes: • Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Window overhangs and/or fins • Non-standard duct location (any location other than attic) HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High quality insulation installation (QII) • Building Envelope Air Leakage • IAQ mechanical ventilation • High R-value Spray Foam Insulation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Verified low -leakage ducts in conditioned space must meet maximum 25 cfm leakage to outside (RA3.1.4.3.8) Domestic Hot Water System Verifications: • Pipe Insulation, All Lines , Registration Number: 219-P010241011A-000-000-0000000-0000 Registration DateMme: 2019-11-13 07:21:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-11-13 07:09:18 I CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Wallace Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 07:06, Wed, Nov 13, 2019 Input File Name: Wallace Residence.ribd16x Page 3 of 21 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Wallace Residence 10517 1 6 10 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Zone 1 Conditioned HVAC Systrem 11 1228 12 DHW Sys 1 n/a Zone 2 Conditioned HVAC System 22 1298 12 1 DHW Sys 1 n/a Zone 3 Conditioned HVAC System 33 1314 12 DHW Sys 1 n/a Zone 4 Conditioned HVAC System 44 1031 12 DHW Sys 1 n/a Zone 5 Conditioned HVAC System 55 1363 12 DHW Sys 1 n/a Zone 6 Conditioned HVAC System 66 814 12 DHW Sys 1 n/a Zone 7 Conditioned HVAC System 77 900 9 DHW Sys 1 n/a Zone 8 Conditioned HVAC System 88 800 9 DHW Sys 1 n/a Zone 9 Conditioned HVAC System 99 1259 12 DHW Sys 1 n/a Zone 10 Conditioned HVAC System 1010 510 12 DHW Sys 1 n/a Registration Number: 219-P010241011A-000-000-0000000-0000 Registration DateMme: 2019-11-13 07:21:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-11-13 07:09:18 i CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Wallace Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 07:06, Wed, Nov 13, 2019 Input File Name: Wallace Residence.ribd16x Page 4 of 21 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) South Exterior Wall Zone 1 R-21 Wall1 180 Back 812 226.5 90 East Exterior Wall Zone 1 R-21 Wall1 90 Left 956 102 90 West Exterior Wall Zone 1 R-21 Wall1 270 Right 620 0 90 North Interior Surface Zone 1»Zone 5 R-21 Wall n/a n/a 216 0 n/a West Interior Surface Zone 1»Zone 2 R-21 Wall n/a n/a 132 0 n/a Roof 3 Zone 1 R-38 Roof Attic Plus n/a n/a 1228 n/a n/a North Exterior Wall Zone 2 R-21 Wall'! 0 Front 794 194.022 90 South Exterior Wall 2 Zone 2 R-21 Wall1 180 Back 1037 437.033 90 West Exterior Wall 2 Zone 2 R-21 Wall1 270 Right 620 20 90 North Interior Surface 2 Zone 2»Zone 4 R-21 Wall n/a n/a 140 0 n/a East Interior Surface Zone 2»Zone 1 R-21 Wall n/a n/a 120 0 n/a West Interior Surface 2 Zone 2»Zone 5 R-21 Wall n/a n/a 312 0 n/a Roof 4 Zone 2 R-38 Roof Attic Plus n/a n/a 1298 n/a n/a North Exterior Wall 2 Zone 3 R-21 Wall1 0 Front 608 77 90 East Exterior Wall 2 Zone 3 R-26 Wall 90 Left 1196 36.0006 90 West Exterior Wall 3 Zone 3 R-21 Wall1 270 Right 1052 189 90 South Interior Surface Zone 3»Zone 1 R-21 Wall n/a n/a 252 0 n/a West Interior Surface 3 Zone 3»Zone 2 R-21 Wall n/a n/a 84 0 n/a North Interior Surface 3 Zone 3»Zone 9 R-21 Wall n/a n/a 492 0 n/a North Exterior Wall 3 Zone 4 R-21 Wall1 0 Front 656 76 90 East Exterior Wall 3 Zone 4 R-21 Wall1 90 Left 956 275.994 90 North Interior Surface 4 Zone 4—Zone 6 R-21 Wall n/a n/a 96 0 n/a South Interior Surface 2 Zone 4»Zone 2 R-21 Wall n/a n/a 216 0 n/a West Interior Surface 4 Zone 4»Zone 6 R-21 Wall n/a n/a 552 0 n/a Roof 5 Zone 4 R-38 Roof Attic Plus n/a n/a 1025.98 n/a n/a North Exterior Wall 4 Zone 5 R-21 Wall1 0 Front 414 6 90 South Exterior Wall 3 Zone 5 R-21 Wall1 180 Back 584 162 90 East Exterior Wall 4 Zone 5 R-21 Wall1 90 Left 812 0 90 West Exterior Wall 4 Zone 5 R-26 Wall 270 Right 910 113.01 90 North Interior Surface 5 Zone 5»Zone 6 R-21 Wall n/a n/a 312 0 n/a Registration Number: 219-P010241011A-000-000-0000000-0000 Registration DateMme: 2019-11-1307:21:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-11-13 07:09:18 1 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Wallace Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 07:06, Wed, Nov 13, 2019 Input File Name: Wallace Residence.ribd16x Page 5 of 21 East Interior Surface 2 Zone 5»Zone 2 R-21 Wall n/a n/a 312 0 n/a Roof 6 Zone 5 R-38 Roof Attic Plus n/a n/a 1339.98 n/a n/a North Exterior Wall 5 Zone 6 R-21 Wall1 0 Front 704 39 90 West Exterior Wall 5 Zone 6 R-26 Wall 270 Right 1216 214 90 South Interior Surface 3 Zone 6»Zone 5 R-21 Wall n/a n/a 292 0 n/a East Interior Surface 3 Zone 6»Zone 10 R-24 Wall n/a n/a 1092 0 n/a Roof 7 Zone 6 R-38 Roof Attic Plus n/a n/a 814 n/a n/a North Exterior Wall 6 Zone 7 R-21 Wall1 0 Front 860 189 90 South Exterior Wall 4 Zone 7 R-21 Wall1 180 Back 340 0 90 East Exterior Wall 5 Zone 7 R-21 Wall1 90 Left 872 74.7 90 West Exterior Wall 6 Zone 7 R-21 Wall1 270 Right 1004 204 90 South Interior Surface 4 Zone 7»Zone 8 R-21 Wall n/a n/a 324 0 n/a Roof 8 Zone 7 R-38 Roof Attic Plus n/a n/a 900 n/a n/a Interior Surface Zone 7»Zone 3 R-30 Floor No Crawlspace n/a n/a 900 n/a n/a South Exterior Wall 5 Zone 8 R-26 Wall 180 Back 1068 96 90 East Exterior Wall 6 Zone 8 R-26 Wall 90 Left 944 225 90 West Exterior Wall 7 Zone 8 R-26 Wall 0 Front 860 8 90 North Exterior Wall 7 Zone 8 R-26 Wall 0 Front 670 49 90 North Interior Surface 6 Zone 8»Zone 7 R-21 Wall n/a n/a 324 0 n/a Roof 9 Zone 8 R-38 Roof Attic Plus n/a n/a 800 n/a n/a West Interior Surface 6 Zone 8»Zone 3 R-30 Floor No Crawlspace n/a n/a 800 n/a n/a North Exterior Wall 8 Zone 9 R-26 Wall 0 Front 848 14 90 East Exterior Wall 7 Zone 9 R-26 Wall 90 Left 1040 240 90 West Exterior Wall 8 Zone 9 R-26 Wall 270 Right 1040 13 90 South Interior Surface 5 Zone 9»Zone 3 R-21 Wall n/a n/a 288 0 n/a Roof 10 Zone 9 R-38 Roof Attic Plus n/a n/a 1259 n/a n/a North Exterior Wall 9 Zone 10 R-24 Wall1 0 Front 288 102 90 East Exterior Wall 8 Zone 10 R-24 Wall1 90 Left 270 68 90 South Exterior Wall 6 Zone 10 R-24 Wall1 180 Back 1920 72 90 Wwest Exterior Wall Zone 10 R-24 Wall1 270 Right 196 6 90 West Interior Surface 5 Zone 10»Zone 6 R-21 Wall n/a n/a 160 0 n/a Interior Surface 2 Zone 10»Zone 10 R-30 Floor No Crawlspace n/a n/a 510 n/a n/a Registration Number: 219-P010241011A-000-000-0000000-0000 Registration Dateffime: 2019-11-13 07:21:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-11-13 07:09:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Wallace Residence Calculation Date/Time: 07:06, Wed, Nov 13, 2019 Calculation Description: Title 24 Analysis Input File Name: Wallace Residence.ribd16x CFI R-PRF-01 Page 6 of 21 OPAQUE SURFACES - Cathedral Ceilings 01 02 03 04 05 06 07 08 09 10 Name Zone Type Orientation Area (ft2) Skylight Area (ft2) Roof Rise (x in 12) Roof Reflectance Roof Emittance Cool Roof Roof Zone 4 R-38 Roof Attic Plus1 Front 5.12 5.02 0.2 0.1 0.85 No Roof 2 Zone 5 R-38 Roof Attic Plus1 Front 23.12 23.02 0.2 0.1 0.85 No ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Zone 1 Attic RoofZone 1 Unventilated 0.2 0.1 085 No No Attic Zone 2 Attic RoofZone 2 Unventilated 0.2 0.1 0.85 No No Attic Zone 4 Attic RoofZone 4 Unventilated 0.2 0.1 0.85 No No Attic Zone 5 Attic RoofZone 5 Unventilated 0.2 0.1 0.85 No No Attic Zone 6 Attic RoofZone 6 Unventilated 0.2 0.1 0.85 No No Attic Zone 7 Attic RoofZone 7 Unventilated 0.2 0.1 0.85 No No Attic Zone 8 Attic RoofZone 8 Unventilated 0.2 0.1 0.85 No No Attic Zone 9 Attic RoofZone 9 Unventilated 0.2 0.1 0.85 No No 9 Registration Number: 219-P010241011A-000-000-0000000-0000 Registration DateMme: 2019-11-13 07:21:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-11-13 07:09:18 I CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Wallace Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 07:06, Wed, Nov 13, 2019 Input File Name: Wallace Residence.ribdl6x Page 7 of 21 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft) U-factor SHGC Exterior Shading Window A Window South Exterior Wall (Back-180) 1 180.0 0.32 0.31 Insect Screen (default) Window 25 Window South Exterior Wall (Back-180) ---- ---- 1 46.5 0.30 0.24 Insect Screen (default) Window K1 Window East Exterior Wall (Left-90) ---- 1 24.0 0.42 0.17 Insect Screen (default) Window 26 Window East Exterior Wall (Left-90) 6.5 12.0 1 78.0 0.30 0.24 Insect Screen (default) Window Al Window North Exterior Wall (Front-0) 7.0 12.0 1 84.0 0.70 0.70 Insect Screen (default) Window 01 Window North Exterior Wall (Front-0) 59 12.0 1.003 71.0 0.30 0.24 Insect Screen (default) Window 02 Window North Exterior Wall (Front-0) 12.9 3.0 1.008 39.0 0.30 0.24 Insect Screen (default) Window 11 Window South Exterior Wall 2 (Back-180) 22.0 12.0 1 264.0 0.30 0.24 Insect Screen (default) Window 22 Window South Exterior Wall 2 (Back-180) 22.0 2.0 1 44.0 0.30 0.24 Insect Screen (default) Window 23 Window South Exterior Wall 2 (Back-180) 11.2 9.2 1.029 106.0 0.34 0.20 Insect Screen (default) Window 24 Window South Exterior Wall 2 (Back-180) 11.2 2.0 1.027 23.0 0.30 0.24 Insect Screen (default) Window 51 Window West Exterior Wall 2 (Right-270) ---- 1 20.0 0.30 0.24 Insect Screen (default) Window 30 Window North Exterior Wall 2 (Front-0) ---- ---- 1 77.0 0.30 0.24 Insect Screen (default) Window M1 Window East Exterior Wall 2 (Left-90) --- - 1 24.0 0.42 0.17 Insect Screen (default) Window 27 Window East Exterior Wall 2 (Left-90) 59 2.0 1.017 12.0 0.30 0.24 Insect Screen (default) Window 31 Window West Exterior Wall 3 (Right-270) --- --- 1 189.0 0.30 0.24 Insect Screen (default) Window B2 Window North Exterior Wall 3 (Front-0) 76 10.0 1 76.0 0.32 0.31 Insect Screen (default) Window B1 Window East Exterior Wall 3 (Left-90) 7.1 10.0 1.014 72.0 0.32 0.31 Insect Screen (default) Window 03 Window East Exterior Wall 3 (Left-90) --- •••• 1 204.0 0.30 0.24 Insect Screen (default) Skylight SO4 Skylight Roof (Front-0) 1 25 0.30 0.30 Skylight S05 Skylight Roof (Front-0) 1 2.5 0.30 0.30 Window 15 Window North Exterior Wall 4 (Front-0) • • • ---- 1 6.0 0.30 1 0.24 Insect Screen (default) Window H1 Window South Exterior Wall 3 (Back-180) 10.0 10.0 1 100.0 0.32 0.31 Insect Screen (default) Window 19 Window South Exterior Wall 3 (Back-180) 2.6 10.0 1 26.0 0.30 0.24 Insect Screen (default) Window 21 Window South Exterior Wall 3 (Back-180) 30 10.0 1 30.0 0.30 0.24 Insect Screen (default) Window 17 Window South Exterior Wall 3 (Back-180) 1 6.0 0.30 0.24 Insect Screen (default) Window 14 Window West Exterior Wall 4 (Right-270) 1 5 6.0 1 9.0 0.30 0.24 1 Insect Screen (default) Window 16 Window West Exterior Wall 4 (Right-270) 11.0 4.1 0.998 45.0 030 0.24 Insect Screen (default) Window 18 Window West Exterior Wall 4 (Right-270) 1.5 6.0 1 9.0 0.30 0.24 Insect Screen (default) Registration Number: 219-P010241011A-000-000-0000000-0000 Registration DateMme: 2019-11-13 07:21:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-11-13 07:09:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Wallace Residence Calculation Date/Time: 07:06, Wed, Nov 13, 2019 Calculation Description: Title 24 Analysis Input File Name: Wallace Residence.ribdl6x CFI R-PRF-01 Page 8 of 21 Window 20 Window West Exterior Wall 4 (Right-270) 3.0 10.0 1 30.0 0.30 0.24 Insect Screen (default) Window 51 2 Window West Exterior Wall 4 (Right-270) ---- ---- 1 20.0 0.30 0.24 Insect Screen (default) Skylight S02 Skylight Roof 2 (Front-0) 1 2.5 0.30 0.30 Skylight S01 Skylight Roof 2 (Front-0) 1 18.0 0.32 0.39 Skylight S03 Skylight Roof 2 (Front-0) 1 2.5 0.30 0.30 Window 09 Window North Exterior Wall 5 (Front-0) ---- 1 27.0 0.30 0.24 Insect Screen (default) Window 10 Window North Exterior Wall 5 (Front-0) 1 12.0 0.30 0.24 Insect Screen (default) Window 11 Window West Exterior Wall 5 (Right-270) 1 13.0 0.30 0.24 Insect Screen (default) Window 12 Window West Exterior Wall 5 (Right-270) 1 45.0 0.30 0.24 Insect Screen (default) Window 13 Window West Exterior Wall 5 (Right-270) 1 12.0 0.30 0.24 Insect Screen (default) Window E1 Window West Exterior Wall 5 (Right-270) 8.0 9.0 1 72.0 0.35 0.22 Insect Screen (default) Window F1 Window West Exterior Wall 5 (Right-270) ---- 1 72.0 0.35 0.22 Insect Screen (default) Window 43 Window North Exterior Wall 6 (Front-0) 4.0 10.0 1 40.0 0.30 0.24 Insect Screen (default) Window 44 Window North Exterior Wall 6 (Front-0) 4.0 10.0 1 40.0 0.30 0.24 Insect Screen (default) Window 46 Window North Exterior Wall 6 (Front-0) 3.0 10.0 1 30.0 0.30 0.24 Insect Screen (default) Window 47 Window North Exterior Wall 6 (Front-0) 3.0 10.0 1 30.0 0.30 0.24 Insect Screen (default) Window P1 Window North Exterior Wall 6 (Front-0) 5.0 9.8 1 49.0 0.42 0.17 Insect Screen (default) Window 40 Window East Exterior Wall 5 (Left-90) --- 1 22.0 0.30 0.24 Insect Screen (default) Window 41 Window East Exterior Wall 5 (Left-90) - 1 12.7 0.30 0.24 Insect Screen (default) Window 42 Window East Exterior Wall 5 (Left-90) ---- 1 40.0 0.30 0.24 Insect Screen (default) Window 45 Window West Exterior Wall 6 (Right-270) 3.5 10.0 1 35.0 0.30 0.24 Insect Screen (default) Window 48 Window West Exterior Wall 6 (Right-270) ---- 1 33.0 0.30 0.24 Insect Screen (default) Window 49 Window West Exterior Wall 6 (Right-270) ---- ---- 1 29.0 0.30 0.24 Insect Screen (default) Window 50 Window West Exterior Wall 6 (Right-270) 1 35.0 0.30 0.24 Insect Screen (default) Window R1 Window West Exterior Wall 6 (Right-270) - - - 1 72.0 0.35 0.22 Insect Screen (default) Window 32 Window South Exterior Wall 5 (Back-180) - 1 52.0 0.30 0.24 1 Insect Screen (default) Window 33 Window South Exterior Wall 5 (Back-180) ---- ---- 1 24.0 0.30 0.24 Insect Screen (default) Window 35 Window South Exterior Wall 5 (Back-180) 1 8.0 0.30 0.24 Insect Screen (default) Window 36 Window South Exterior Wall 5 (Back-180) ---- 1 12.0 0.30 0.24 Insect Screen (default) Window 37 Window East Exterior Wall 6 (Left-90) 1 39.0 0.30 024 Insect Screen (default) Window 38 Window East Exterior Wall 6 (Left-90) 58 10.0 1 580 0.30 0.24 Insect Screen (default) Window 39 Window East Exterior Wall 6 (Left-90) 4.8 10.0 1 48.0 030 0.24 Insect Screen (default) Window P3 Window East Exterior Wall 6 (Left-90) ---- -- 1 80.0 0.35 0.22 Insect Screen (default) Registration Number: 219-P010241011A-000-000-0000000-0000 Registration Date/Time: 2019-11-13 07:21:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-11-13 07:09:18 t CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Wallace Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 07:06, Wed, Nov 13, 2019 Input File Name: Wallace Residence.ribd16x CF1 R-PRF-01 Page 9 of 21 Window 34 Window West Exterior Wall 7 (Front-0) 4.0 2.0 1 8.0 030 0.24 Insect Screen (default) Window Q1 Window North Exterior Wall 7 (Front-0) 5.0 9.8 1 49.0 0.42 0.17 Insect Screen (default) Window 28 Window North Exterior Wall 8 (Front-0) 1 14.0 0.30 0.24 Insect Screen (default) Window N2 Window East Exterior Wall 7 (Left-90) --- ---- 1 80.0 0.59 0.57 Insect Screen (default) Window N3 Window East Exterior Wall 7 (Left-90) ---- --- 1 80.0 0.59 0.57 Insect Screen (default) Window N4 Window East Exterior Wall 7 (Left-90) ---- ---- 1 80.0 0.59 057 Insect Screen (default) Window 29 Window West Exterior Wall 8 (Right-270) ---- ---- 1 13.0 0.30 024 Insect Screen (default) Window W04 Window North Exterior Wall 9 (Front-0) ---- ---- 1 280 0.30 0.24 Insect Screen (default) Window W06 Window North Exterior Wall 9 (Front-0) ---• 1 65.0 0.30 0.24 Insect Screen (default) Window W07 Window North Exterior Wall 9 (Front-0) - - 1 9.0 0.30 0.24 Insect Screen (default) Window 05 Window East Exterior Wall 8 (Left-90) ---- ---- 1 68.0 0.30 0.24 Insect Screen (default) Window D21 Window South Exterior Wall 6 (Back-180) ---- --- 1 72.0 0.35 0.22 Insect Screen (default) Window 08 Window Wwest Exterior Wall (Right-270) - - 1 6.0 0.30 0.24 Insect Screen (default) Registration Number: 219-P010241011A-000-000-0000000-0000 Registration Dateffime: 2019-11-13 07:21:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-11-13 07:09:18 i CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Wallace Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 07:06, Wed, Nov 13, 2019 Input File Name: Wallace Residence.ribd16x Page 10 of 21 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up Window 26 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window Al 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 01 4 0.1 4 4 0 0 0 0 0 0 0 1 0 0 Window 02 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 11 12 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 22 12 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 23 12 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 24 12 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 27 8 0.1 8 8 0 0 0 0 0 0 0 0 0 Window B2 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window B1 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window H1 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 19 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window 21 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 14 4 1 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 16 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 18 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 20 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Window E1 8 0.1 8 8 0 0 0 0 0 0 0 0 0 Window 43 6 0.1 6 6 0 0 0 0 0 0 0 0 0 Window 44 12 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 46 12 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 47 12 0.1 4 4 0 0 0 0 0 0 0 0 0 Window P1 12 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 45 12 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 38 12 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 39 12 0.1 4 4 0 0 0 0 0 0 0 0 0 Window 34 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Registration Number: 219-P010241011A-000-000-0000000-0000 Registration Dateffime: 2019-11-13 07:21:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-11-13 07:09:18 I CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Wallace Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 07:06, Wed, Nov 13, 2019 Input File Name: Wallace Residence.ribd16x CFI R-PRF-01 Page 11 of 21 Window Q1 12 0.1 4 4 0 0 0 0 0 0 0 0 0 Registration Number: 219-Po10241011A-000-000-0000000-0000 Registration DateRme: 2019-11-13 07:21:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-11-13 07:09:18 I CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Wallace Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 07:06, Wed, Nov 13, 2019 Input File Name: Wallace Residence. ribd16x CF1 R-PRF-01 Page 12 of 21 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers • Under Roof Joists: R-27.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofZone 1 Attic Roofs Wood Framed Ceiling in. O.C. R 40 0.025 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: R-21 / 2x6 R-21 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. O.0 R 21 0.064 Other Side Finish: Gypsum Board Inside Finish: Gypsum Board Cavity / Frame: R-21 / 2x6 R-21 Wall'! Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.069 Exterior Finish: 3 Coat Stucco Ceilings (below Inside Finish: Gypsum Board R-38 Roof Attic Plus attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. none 0.481 Cavity/Frame: no insul. /2x4 • Under Roof Joists: R-27.0 insul. • Cavity / Frame: R-13.0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofZone 2 Attic Roofs Wood Framed Ceiling in. O.C. R 40 0.025 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: R-26 / 2x8 R-26 Wall Exterior Walls Wood Framed Wall 2x8 @ 16 in. O.C. R 26 0.055 Exterior Finish: 3 Coat Stucco • Under Roof Joists: R-27.0 insul. • Cavity / Frame: R-13.0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofZone 4 Attic Roofs Wood Framed Ceiling in. O.C. R 40 0.025 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Sheathing/Insulation: R40 Sheathing • Cavity / Frame: no insul. / 2x4 • Roof Deck: Wood Siding/sheathing/decking R-38 Roof Attic Plusl Cathedral Ceilings Wood Framed Ceiling 2x4 @ 24 in. O.C. none 0.024 Roofing: Light Roof (Asphalt Shingle) • Under Roof Joists: R-27.0 insul. Cavity / Frame: R-13.0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofZone 5 Attic Roofs Wood Framed Ceiling in. O.C. R 40 0.025 Roofing: Light Roof (Asphalt Shingle) Under Roof Joists: R-27.0 insul. Cavity / Frame: R-13.0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck. Wood Siding/sheathing/decking Attic RoofZone 6 Attic Roofs Wood Framed Ceiling in. O.C. R 40 0 025 Roofing: Light Roof (Asphalt Shingle) Inside Finish: Gypsum Board Cavity / Frame: R-24 / 2x6 R-24 Wall Interior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 24 0.060 Other Side Finish: Gypsum Board Registration Number: 219-P010241011A-000-000-0000000-0000 Registration DateMme: 2019-11-13 07:21:05 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-11-13 07:09:18 I CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Wallace Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 07:06, Wed, Nov 13, 2019 Input File Name: Wallace Residence.ribd16x CF1 R-PRF-01 Page 13 of 21 Under Roof Joists: R-27.0 insul. Cavity / Frame: R-13.0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofZone 7 Attic Roofs Wood Framed Ceiling in. O.C. R 40 0.025 Roofing: Light Roof (Asphalt Shingle) • Floor Surface: Carpeted • Floor Deck: Wood Siding/sheathing/decking Cavity/Frame: R-38 in 11-1/4 in. (R-37) / R 38 in 11-1/4 2x12 R-30 Floor No Crawlspace Interior Floors Wood Framed Floor 2x12 @ 16 in. O.C. in. cavity (R-37) 0.028 Ceiling Below Finish: Gypsum Board • Under Roof Joists: R-27.0 insul. Cavity / Frame: R-13.0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofZone 8 Attic Roofs Wood Framed Ceiling in. O.C. R 40 0.025 Roofing: Light Roof (Asphalt Shingle) • Under Roof Joists: R-27.0 insul. • Cavity / Frame: R-13.0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofZone 9 Attic Roofs Wood Framed Ceiling in. O.C. R 40 0.025 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: R-24 / 2x6 R-24 Wall1 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 24 0.065 Exterior Finish: 3 Coat Stucco SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Slab -on -Grade Zone 1 1228 90 None 1 No Slab -on -Grade 2 Zone 2 1298 70 None 1 No Slab -on -Grade 3 Zone 3 1314 110 None 1 No Slab -on -Grade 4 Zone 4 1031 120 None 1 No Slab -on -Grade 5 Zone 5 1363 140 None 1 No Slab -on -Grade 6 Zone 6 814 70 None 1 No Slab -on -Grade 7 Zone 9 1259 140 None 1 No Slab -on -Grade 8 Zone 10 510 30 None 1 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Required Required 2018.4 Registration Number: 219-P010241011A-000-000-0000000-0000 Registration Date/Time: 2019-11-13 07:21:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-11-13 07:09:18 I CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Wallace Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 07:06, Wed, Nov 13, 2019 Input File Name: Wallace Residence.ribd16x CF1 R-PRF-01 Page 14 of 21 WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW (HERS req'd) Pipe Insulation, All Lines DHW Heater 1 (2) 2 .0% WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Uniform Energy Factor / Energy Factor / Efficiency Input Rating / Pilot / Thermal Efficiency Tank Insulation R-value (Int/Ext) Standby Loss / Recovery Eff First Hour Rating / Flow Rate NEEA Heat Pump Brand / Model / Other Tank Location or Ambient Condition DHW Heater 1 Gas Small Storage 2 55 0.97 EF — 75 kBtu/hr R-0/R-0 0 n/a n/a n/a WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/2 Pipe Insulation, All Lines n/a n/a n/a n/a n/a Registration Number: 219-P010241011A-000-000-0000000-0000 Registration Date/Time: 2019-11-13 07:21:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-11-13 07:09:18 , CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Wallace Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 07:06, Wed, Nov 13, 2019 Input File Name: Wallace Residence.ribd16x CFI R-PRF-01 Page 15 of 21 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC Systrem 11 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC System 22 Other Heating and Cooling System Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2 HVAC System 33 Other Heating and Cooling System Heating Component 3 Cooling Component 3 HVAC Fan 3 Air Distribution System 3 HVAC System 44 Other Heating and Cooling System Heating Component 4 Cooling Component 4 HVAC Fan 4 Air Distribution System 4 HVAC System 55 Other Heating and Cooling System Heating Component 5 Cooling Component 5 HVAC Fan 5 Air Distribution System 5 HVAC System 66 Other Heating and Cooling System Heating Component 6 Cooling Component 6 HVAC Fan 6 Air Distribution System 6 HVAC System 77 Other Heating and Cooling System Heating Component 7 Cooling Component 7 HVAC Fan 7 Air Distribution System 7 HVAC S stem 88 y Other Heating and Cooling System Heatin 9 Component 8 Cooling Component 8 HVAC Fan 8 Air Distribution System 8 HVAC System 99 Heat Pump Heating and Cooling System Heat Pump System 9 Heat Pump System 9 HVAC Fan 9 Air Distribution System 9 HVAC System 1010 Heat Pump Heating and Cooling System Heat Pump System 10 Heat Pump System 10 HVAC Fan 10 Air Distribution System 10 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Efficiency Heating Component 1 CntrlFurnace 1 80 AFUE Heating Component 2 CntrlFurnace 1 80 AFUE Heating Component 3 CntrlFurnace 1 96 AFUE Heating Component 4 CntrlFurnace 1 96 AFUE Heating Component 5 CntrlFurnace 1 96 AFUE Heating Component 6 CntrlFurnace 1 80 AFUE Heating Component 7 CntrlFurnace 1 96 AFUE Heating Component 8 CntrlFurnace 1 96 AFUE Registration Number: 219-P010241011A-000-000-0000000-0000 Registration DateMme: 2019-11-13 07:21:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-11-13 07:09:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Wallace Residence Calculation Date/Time: 07:06, Wed, Nov 13, 2019 Calculation Description: Title 24 Analysis Input File Name: Wallace Residence. ribd 1 6x CF1 R-PRF-01 Page 16 of 21 HVAC - HEAT PUMPS 01 02 03 04 05 1 06 07 08 09 10 11 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER Heat Pump System 9 SplitHeatPump 1 8.3 34800 27300 19.3 12.3 Not Zonal Multi -speed Heat Pump System 9-hers-cool Heat Pump System 10 SplitHeatPump 1 10 37000 22000 22 145 Not Zonal Multi -speed Heat Pump System 10-hers-cool HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Efficiency Name System Type Number of Units EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 SplitAirCond 1 13 20.5 Not Zonal Multi -speed Cooling Component 1-hers-cool Cooling Component 2 SplitAirCond 1 13 20.5 Not Zonal Multi -speed Cooling Component 2-hers-cool Cooling Component 3 SplitAirCond 1 12 20 Not Zonal Multi -speed Cooling Component 3-hers-cool Cooling Component 4 SplitAirCond 1 13 20 Not Zonal Multi -speed Cooling Component 4-hers-cool Cooling Component 5 SplitAirCond 1 13 20 Not Zonal Multi -speed Cooling Component 5-hers-cool Cooling Component 6 SplitAirCond 1 13 21 Zonally Controlled Multi -speed Cooling Component 6-hers-cool Cooling Component 7 SplitAirCond 1 13 20 Not Zonal Multi -speed Cooling Component 7-hers-cool Cooling Component 8 SplitAirCond 1 13 20 Not Zonal Multi -speed Cooling Component 8-hers-cool Registration Number: 219-P010241011A-000-000-0000000-0000 Registration Date/Time: 2019-11-13 07:21:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-11-13 07:09:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFI R-PRF-01 Project Name: Wallace Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 07:06, Wed, Nov 13, 2019 Input File Name: Wallace Residence.ribd16x Page 17 of 21 HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Required Required Cooling Component 2-hers-cool Required 350 Required Required Required Cooling Component 3-hers-cool Required 350 Required Required Required Cooling Component 4-hers-cool Required 350 Required Required Required Cooling Component 5-hers-cool Required 350 Required Required Required Cooling Component 6-hers-cool Required 350 Required Required Required Cooling Component 7-hers-cool Required 350 Required Required Required Cooling Component 8-hers-cool Required 350 Required Required Required Heat Pump System 9-hers-cool Required 350 Required Required Not Required Heat Pump System 10-hers-cool Required 350 Required Required Required Registration Number: 219-P010241011A-000-000-0000000-0000 Registration Dateffime: 2019-11-13 07:21:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-01162019-1149 Report Generated at: 2019-11-13 07:09:18 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Wallace Residence Calculation Date/Time: 07:06, Wed, Nov 13, 2019 Calculation Description: Title 24 Analysis Input File Name: Wallace Residence.ribd16x CFI R-PRF-01 Page 18 of 21 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 Lowl-lCod Sealed and tested 8 Conditioned zone (VLL) None Air Distribution System 1-hers-dist Air Distribution System 2 Lowl-lCod Sealed and tested 8 Conditioned zone (VLL) None Air Distribution System 2-hers-dist Air Distribution System 3 Lowl-lCod Sealed and tested 8 Conditioned zone (VLL) None Air Distribution System 3-hers-dist Air Distribution System 4 LowLlCod Sealed and tested 8 Conditioned zone (VLL) None Air Distribution System 4-hers-dist Air Distribution System 5 Lowl-lCod Sealed and tested 8 Conditioned zone (VLL) None Air Distribution System 5-hers-dist Air Distribution System 6 Lowl-lCod Sealed and tested 8 Conditioned zone (VLL) None Air Distribution System 6-hers-dist Air Distribution System 7 LowLlCod Sealed and tested 8 Conditioned zone (VLL) None Air Distribution System 7-hers-dist Air Distribution System 8 LowLlCod Sealed and tested 8 Conditioned zone (VLL) None Air Distribution System 8-hers-dist Air Distribution System 9 Lowl-lCod Sealed and tested 8 Conditioned zone (VLL) None Air Distribution System 9-hers-dist Air Distribution System 10 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 10-hers-dist Registration Number: 219-Po10241011A-000-000-0000000-0000 Registration DateMme: 2019-11-13 07:21:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-11-13 07:09:18 / CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Wallace Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 07:06, Wed, Nov 13, 2019 Input File Name: Wallace Residence.ribd16x Page 19 of 21 HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required See RA3.1.4.3.8 Required Not Required Not Required Not Required n/a Air Distribution System 2-hers-dist Required See RA3.1.4.3.8 Required I Not Required Not Required Not Required n/a Air Distribution System 3-hers-dist Required See RA3.1.4.3 8 Required Not Required Not Required Not Required n/a Air Distribution System 4-hers-disc Required See RA3.1.4.3.8 Required Not Required Not Required Not Required n/a Air Distribution System 5-hers-dist Required See RA3.1.4.3.8 Required Not Required Not Required Not Required n/a Air Distribution System 6-hers-dist Required See RA3.1.4.3.8 Required Not Required Not Required Not Required n/a Air Distribution System 7-hers-dist Required See RA3.1.4.3.8 Required Not Required Not Required Not Required n/a Air Distribution System 8-hers-dist Required See RA3.1.4.3.8 Required Not Required Not Required Not Required n/a Air Distribution System 9-hers-dist Required See RA3.1.4.3 8 Required Not Required Not Required Not Required n/a Air Distribution System 10-hers-dist Required 5.0 Not Required I Not Required Not Required Not Required n/a HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2-hers-fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.58 HVAC Fan 3-hers-fan HVAC Fan 4 Single Speed PSC Furnace Fan 0.58 HVAC Fan 4-hers-fan HVAC Fan 5 Single Speed PSC Furnace Fan 0.58 HVAC Fan 5-hers-fan HVAC Fan 6 Single Speed PSC Furnace Fan 0.58 HVAC Fan 6-hers-fan HVAC Fan 7 Single Speed PSC Furnace Fan 0.58 HVAC Fan 7-hers-fan HVAC Fan 8 Single Speed PSC Furnace Fan 0.58 HVAC Fan 8-hers-fan HVAC Fan 9 Single Speed PSC Furnace Fan 0.58 HVAC Fan 9-hers-fan HVAC Fan 10 Single Speed PSC Furnace Fan 0.58 HVAC Fan 10-hers-fan Registration Number: 219-P010241011A-000-000-0000000-0000 Registration DateMme: 2019-11-13 07:21:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-11-13 07:09:18 f CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Wallace Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 07:06, Wed, Nov 13, 2019 Input File Name: Wallace Residence. ribd 1 6x CFI R-PRF-01 Page 20 of 21 HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 HVAC Fan 2-hers-fan Required 0.58 HVAC Fan 3-hers-fan Required 0.58 HVAC Fan 4-hers-fan Required 0.58 HVAC Fan 5-hers-fan Required 0.58 HVAC Fan 6-hers-fan Required 0.58 HVAC Fan 7-hers-fan Required 0.58 HVAC Fan 8-hers-fan Required 058 HVAC Fan 9-hers-fan Required 0.58 HVAC Fan 10-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 158 0.25 Default 0 Required Registration Number: 219_P010241011A-000-000-0000000-0000 Registration Date/Time: 2019-11-13 07:21:05 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-11-13 07:09:18 ( CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Wallace Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 07:06, Wed, Nov 13, 2019 Input File Name: Wallace Residence.ribd16x CF1 R-PRF-01 Page 21 of 21 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: fOAe4 2?i Butch White Company: Signature Date: Breeze Air Conditioning LLC 2019-11-13 07:21:05 Address: CEA/HERS Certification Identification (If applicable): 75-145 ST CHARLES PLACE City/State/Zip: Phone: PALM DESERT, CA 92211 760-346-0855 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Butch White Company: Date Signed: Breeze Air Conditioning LLC 2019-11-13 07:21:05 Address: License: 75-145 ST CHARLES PLACE 1045015 City/State/Zip: Phone: PALM DESERT, CA 92211 760-346-0855 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 219-P010241011A-000-000-0000000-0000 Registration Date/Time: 2019-11-13 07:21:05 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Easy to Verify at CaICERTS.com HERS Provider: CaICERTS inc. Report Generated at: 2019-11-13 07:09:18