BRES2015-0391 Title 24 Revision 1BUILDING ENERGY ANALYSIS REPORT cjp(e /(Opv PROJECT: Madison Club 23B 81-382 Amundson Ave. La Quinta, CA 92253:' Project Designer: Kristi Hanson Architects, Inc. 72-185 Painters Path STE A Palm Desert, CA 92260 (760) 776-4068 Report Prepared by: Jon Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, CA 9 2�� (760) 200-478 BUILD of CUNTA TNG & SAFETY A �EpT FO � CONs "2- E83 NSUCTION �A7-E Job Number: RE6.EIVED Date: APR 11 2016, 4/7/2016 CITY OF LA QUINTA COMMUNITY DEVELOPMENT The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. I iEnergyPro 6.7 by EnergySoft User Number: 6712 ID: of400 v TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R -PRF -01-E Certificate of Compliance Form RMS -1 Residential Measures Summary Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads EnergyPro 6.7 by EnergySoft Job Number: ID: User Number: 6712 1 2 3 19 21 25 30 35 40 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Club 23B Calculation Date/Time: 11:43, Thu, Apr 07, 2016 Calculation Description: Title 24 Analysis Input File Name: Madison Club 2313-Kristi Hanson-15.xml CFi R -MF -01 Page 1 of 16 GENERAL INFORMATION 01 Building Complies with Computer Performance 01 Project Name Madison Club 23B 03 This building Incorporates one or,more Speclal Features shown below .•� * /� _ .-. 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDV/ft2-yr) 03 Project Location 81-382 Amundson Ave. Compliance Margin Percent Improvement 04 City La Quinta 05 Standards Version Compliance 2015 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ15 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 135 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 8044 15 Number of Zones 5 16 Slab Area (ft2) 6474 17 Number of Stories 2 18 Addition Cond. Floor Area N/A 19 Natural Gas Available Yes 20 Addition Slab Area (ff) N/A 21 Glazing Percentage (%) 40.7% COMPLIANCE RESULTS _ 01 Building Complies with Computer Performance 02 This building Incorporates features that require field testing and/or verification by a certified HERS iater'under' the supervision of a CEC-approved HERS provider. 03 This building Incorporates one or,more Speclal Features shown below .•� * /� _ .-. 06 Registration Number: 215-N6343967C-000000000-0000 Registration Date/Time: 2016-04-07 11:58:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF113-03092016-744 Report Generated at: 2016-04-07 11:45:48 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 3.98 5.44 -1.46 -36.7% Space Cooling 110.01 105.93 4.08 3.7% IAQ Ventilation 1.11 1.11 0.00 0.0% Water Heating 3.19 4.25 -1.06 -33.2% Photovoltaic Offset ---- 0.00 0.00 ---- Compliance Energy Total 118.29 116.73 1.56 1.3% Registration Number: 215-N6343967C-000000000-0000 Registration Date/Time: 2016-04-07 11:58:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF113-03092016-744 Report Generated at: 2016-04-07 11:45:48 { CERTIFICATE OF COMPLIANCE- RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-IAF-01 Project Name: Madison Club 2313 Calculation Date/Time: 11:43, Thu, Apr 07, 2016 - Page 2 of 16• Calculation Description: -Title 24 Analysis Input File Name: Madison Club 2313-Kristi Hanson-15.xml - • - *r - - - REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for, this computer analysis. Window overhangs and/or fins HERS FEATURE SUMMARY ; The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. - Building -level Verifications: ' High Quality Insulation Installation (QII)- IAO mechanical ventilation Cooling System Verifications: , Minimum Airflow - Verified EER w Verified SEER • } Refrigerant Charge - Fan Efficacy Watts/CFM } HVAC Distribution System Verifications: j Duct Sealing _!J Domestic Hot Water System Veriflcatlons: None-- �� �'�i" '• r� N. F ENERGY DESIGN RATING ! / f U . 40�� II A( h ` j1 � K 11 `� 3 This is the sum of the annual TDV energy consumption for energy use`cornponentsincluded in the p&iformance compliance approach for the Standard Design Building (Energy Budget) and the annual . TDV energy consumption for lighting and components not regulated by Title 24, Part.6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. r y T i.. �� •� 91 1 1 i.J .tz - Eti - Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDVtf2-yr)' 152.56 151.00 1.56 1.0% includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING -FEATURES INFORMATION - - • = 01 02 03 04 05 06 07 Project Name • Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones' Number of Ventilation Cooling Systems Number of Water Heating Systems Madison Club 23B 8044 1 15 5 5 1 Registration Number: 215-1\16343967C-000000000-0000 Registration Date/Time: 2016-04-07 11:58:25 CA Building Energy Efficiency Standards 2013 Residential Compliance Report Version - CF1R-03092016-744 R r HERS Provider: CaICERTS inc. Report Generated at: 2016-04-07 11:45:48 CERTIFICATE OF COMPLIANCE- RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Club 23B Calculation Date/Time: 11:43, Thu, Apr 07, 2016 Calculation Description: Title 24 Analysis Input File Name: Madison Club 236-Kristi Hanson-15.xml CF1 R-fiF-01 Page 3 of 16 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 off nook dining Conditioned HVAC 1 off kit nookl 1621 9 DHW Sys 1 great entry Conditioned HVAC 2 grt enry2 1659 9 DHW Sys 1 masterguest Conditioned HVAC 3 mstr gest3 1781 9 DHW Sys 1 guest living Conditioned HVAC 4 gest liv4 1413 9 DHW Sys 1 2nd master Conditioned HVAC 5 2nd5 1570 9 DHW Sys 1 �j i 1l 0 V f Registration Number: 215-N6343967C-000000000-0000 Registration Date/Time: 2016-04-07 11:58:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF113-03092016-744 Report Generated at: 2016-04-07 11:45:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Club 23B Calculation Date/Time: 11:43, Thu, Apr 07, 2016 Calculation Description: Title 24 Analysis Input File Name: Madison Club 23B-Kristi Hanson-15.xml CF1 R -PAF -01 Page 4 of 16 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft) Tilt (deg) NE Wall off nook dining R-21 Wall (W.21.2x6.16) 45 Right 832 339 90 SE Wall off nook dining R-21 Wall (W.21.2x6.16) 135 Front 464 129.1 90 SW Wall off nook dining R-21 Wall (W.21.2x6.16) 225 Left 1616 467.313 90 NW Wall off nook dining R-21 Wall (W.21.2x6.16) 315 Back 400 238.8 90 Roof off nook dining R-38 Roof Attic 522 NE Wall 2 great entry R-21 Wall (W.21.2x6.16) 45 Right 684 120 90 SE Wall 2 great entry R-21 Wall (W.21.2x6.16) 135 Front 416 260.536 90 SW Wall 2 great entry R-21 Wall (W.21.2x6.16) 225 Left 684 90 NW Wall 2 great entry R-21 Wall (W.21.2x6.16) 315 Back 455 378.5 90 Roof 2 great entry R-38 Roof Attic 1659 NE Wall 3 masterguest R-21 Wall (W.21.2x6.16) 45 Right 657 142.4 90 SE Wall 3 masterguest R-21 Wall (W.21.2x6.16) 135 Front 576 104.2 90 SW Wall masterguest R-21 Wall (W.21.2x6.16)1 /225 Left 200 21.5 90 NW Wall 3 masterguest R-21 Wall (W.21.2x6.16) Y 315 Back 1 480 146.4 90 Roof 3 masterguest R-38 Roof Attic - 1781 NE Wall 4 guest living R-21 Wall (W.21.2x6.16) 45 -�,+ Right 907 203 90 SE Wall 4 guest living R-21 Wall (W.21.2x6.16) 135 Front 619 70.6 90 SW Wall 4 guest living R-21 Wall (W.21.2x6.16) 225 Left 907 199.6 90 NW Wall 4 guest living R-21 Wall (W.21.2x6.16) 315 Back 619 129.6 90 Roof 4 guest living R-38 Roof Attic 1413 NE Wall 5 2nd master R-21 Wall (W.21.2x6.16) 45 Right 780 126 90 SE Wall 5 2nd master R-21 Wail (W.21.2x6.16) 135 Front 350 27 90 SW Wall 5 2nd master R-21 Wall (W.21.2x6.16) 225 Left 780 174.9 90 NW Wall 5 2nd master R-21 Wall (W.21.2x6.16) 315 Back 350 17.8 90 Roof 5 2nd master R-38 Roof Attic 1570 Registration Number: 215-N6343967C-000000000-0000 Registration Date/Time: 2016-04-07 11:58:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03092016-744 Report Generated at: 2016-04-07 11:45:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Club 23B Calculation Date/Time: 11:43, Thu, Apr 07, 2016 Calculation Description: Title 24 Analysis Input File Name: Madison Club 236-Kristi Hanson-15.xml CF1 R -PRF -01 Page 5 of 16 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic off nook dining Attic Roofoff nook dining Ventilated 3 0.1 0.85 No No Attic great entry Attic Roofgreat entry Ventilated 3 0.1 0.85 No No Attic masterguest Attic Roofmasterguest Ventilated 3 0.1 0.85 No No Attic guest living Attic Roofguest living Ventilated 3 0.1 0.85 No No Attic 2nd master Attic Roof2nd master Ventilated 3 0.1 0.85 No No QRS PR, 0 i E R Registration Number: 215-N6343967C-000000000-0000 Registration Date/Time: 2016-04-07 11:58:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03092016-744 Report Generated at: 2016-04-07 11:45:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Club 23B Calculation Date/Time: 11:43, Thu, Apr 07, 2016 Calculation Description: Title 24 Analysis Input File Name: Madison Club 23B-Kristi Hanson-15.xml CF1 R-PhF-01 1 Page 6 of 16 WINDOWS 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multipll er Area (ft) 1.11 -factor SHGC Exterior Shading K3 Window NE Wall (Right -45) 11.0 10.0 1 110.0 0.28 0.18 Insect Screen (default) 17 Window NE Wall (Right -45) 11.6 10.0 1 116.0 0.32 0.24 Insect Screen (default) K2 Window NE Wali (Right -45) 11.3 10.0 1 113.0 0.28 0.18 Insect Screen (default) 12 Window SE Wall (Front -135) 10.9 10.0 1 109.0 0.28 0.18 Insect Screen (default) K3 2 Window SW Wall (Left -225) 11.0 10.0 1 110.0 0.28 0.18 Insect Screen (default) 11 Window SW Wall (Left -225) 12.1 10.0 1 121.0 0.32 0.24 Insect Screen (default) J2 Window SW Wall (Left -225) 2.0 8.0 1 16.0 0.28 0.18 Insect Screen (default) J1 Window SW Wall (Left -225) 2.0 8.0 1 16.0 0.28 0.18 Insect Screen (default) H1 Window SW Wall (Left -225) 5.3 4.0 1 21.2 0.28 0.18 Insect Screen (default) 10 Window SW Wall (Left -225) 11.0 10.0 1 110.0 0.32 0.24 Insect Screen (default) G2 Window SW Wall (Left -225) 6.3 6.9 1.001 43.5 0.28 0.18 Insect Screen (default) G3 Window SW Wall (Left -225) 2.8 2.0 1 5.6 0.28 0.18 Insect Screen (default) 08 Window SW Wall (Left -225) 3.0 8.0 1 24.0 0.32 0.24 Insect Screen (default) 07 Window NW Wall (Back -315) 19.9 10.0 1 199.0 0.32 0.24 Insect Screen (default) G1 Window NW Wall (Back -315) 19.9 2.0 1 39.8 0.28 0.18 Insect Screen (default) F3 Window NE Wall 2 (Right -45) ---- ---- 1 60.0 0.28 0.18 Insect Screen (default) F2 Window NE Wall 2 (Right -45) ---- ---- 1 60.0 0.28 0.18 Insect Screen (default) 61 Window SE Wall 2 (Front -135) 1.5 5.5 1.006 8.3 0.28 0.18 Insect Screen (default) A4 Window SE Wall 2 (Front -135) 2.9 12.2 1.001 35.4 0.28 0.18 Insect Screen (default) A5 Window SE Wall 2 (Front -135) 2.8 3.3 0.996 9.2 0.28 0.18 Insect Screen (default) 01 Window SE Wall 2 (Front -135) 8.5 10.0 1 85.0 0.32 0.24 Insect Screen (default) A3 Window SE Wall 2 (Front -135) 5.3 3.3 1.001 17.5 0.28 0.18 Insect Screen (default) Al Window SE Wall 2 (Front -135) 2.9 12.2 1.001 35.4 0.28 0.18 Insect Screen (default) A2 Window SE Wall 2 (Front -135) 2.8 3.3 1.006 9.3 0.28 0.18 Insect Screen (default) M1 Window SE Wall 2 (Front -135) ---- ---- 1 60.4 0.28 0.18 Insect Screen (default) F5 Window NW Wall 2 (Back -315) 5.8 9.5 1 55.1 0.28 0.18 Insect Screen (default) F6 Window NW Wall 2 (Back -315) 5.8 3.0 1 17.4 0.28 0.18 Insect Screen (default) 06 Window NW Wall 2 (Back -315) 17.0 12.0 = 204.0 0.32 0.24 Insect Screen (default) F4 Window NW Wall 2 (Back -315) 17.0 3.0 1 1 1 51.0 0.28 0.18 Insect Screen (default) Registration Number: 215-N6343967C-000000000-0000 Registration Date/Time: 2016-04-07 11:58:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03092016-744 Report Generated at: 2016-04-07 11:45:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Club 23B Calculation Date/Time: 11:43, Thu, Apr 07, 2016 Calculation Description: Title 24 Analysis Input File Name: Madison Club 23B-Kristi Hanson-15.xmi CF1 R -PAF -01 ' Page 7 of 16 F1 Window NW Wall 2 (Back -315) 5.1 10.0 1 51.0 0.28 0.18 Insect Screen (default) E1 Window NE Wall 3 (Right -45) ---- ---- 1 96.0 0.28 0.18 Insect Screen (default) E2 Window NE Wall 3 (Right -45) ---- ---- 1 19.2 0.28 0.18 Insect Screen (default) D3 Window NE Wall 3 (Right -45) ---- ---- 1 5.6 0.28 0.18 Insect Screen (default) D2 Window NE Wall 3 (Right -45) ---- ---- 1 21.6 0.28 0.18 Insect Screen (default) D1 Window SE Wall 3 (Front -135) ---- ---- 1 19.2 0.28 0.18 Insect Screen (default) 02 Window SE Wall 3 (Front -135) ---- ---- 1 85.0 0.32 0.24 Insect Screen (default) C1 Window SW Wall 3 (Left -225) ---- ---- 1 21.5 0.28 0.18 Insect Screen (default) 05 Window NW Wall 3 (Back -315) ---- ---- 1 78.0 0.32 0.24 Insect Screen (default) E5 Window NW Wall 3 (Back -315) ---- ---- 1 15.6 0.28 0.18 Insect Screen (default) E3 Window NW Wall 3 (Back -315) ---- ---- 1 44.0 0.28 0.18 Insect Screen (default) E4 Window NW Wall 3 (Back -315) ---- ---- 1 8.8 0.28 0.18 Insect Screen (default) 21 Window NE Wall 4 (Right -45) 10.0 9.0 1 90.0 0.32 0.24 Insect Screen (default) R2 Window NE Wall 4 (Right -45) 2.0 8.0 1 16.0 0.28 0.18 Insect Screen (default) R1 Window NE Wall 4 (Right -45) 2.0 8.0 1 16.0 0.28 0.18 Insect Screen (default) 19 Window NE Wall 4 (Right -45) 9.0 9.0 1 81.0 0.32 0.24 Insect Screen (default) 01 Window SE Wall 4 (Front -135) - 6.3 2.0 1 12.6 0.28 0.18 Insect Screen (default) P3 Window SE Wall 4 (Front -135) 2.0 9.0 1 18.0 0.28 0.18 Insect Screen (default) N4 Window SE Wall 4 (Front -135) 4.0 10.0 1 40.0 0.28 0.18 Insect Screen (default) P2 Window SW Wall 4 (Left -225) 2.0 9.0 1 18.0 0.28 0.18 Insect Screen (default) P1 Window SW Wall 4 (Left -225) 2.0 9.0 1 18.0 0.28 0.18 Insect Screen (default) N3 Window SW Wall 4 (Left -225) 6.2 10.0 1 62.0 0.28 0.18 insect Screen (default) N2 Window SW Wall 4 (Left -225) 6.2 10.0 1 62.0 0.28 0.18 Insect Screen (default) S2 Window SW Wall 4 (Left -225) 4.4 9.0 1 39.6 0.28 0.18 Insect Screen (default) N1 Window NW Wall 4 (Back -315) 4.0 10.0 1 40.0 0.28 0.18 Insect Screen (default) 18 Window NW Wall 4 (Back -315) 7.7 10.0 1 77.0 0.32 0.24 Insect Screen (default) S1 Window NW Wall 4 (Back -315) 6.3 2.0 1 12.6 0.28 0.18 insect Screen (default) 122 Window NE Wall 5 (Right -45) 4.0 9.0 1 36.0 0.28 0.18 Insect Screen (default) 22 Window NE Wall 5 (Right -45) 10.0 9.0 1 90.0 0.32 0.24 Insect Screen (default) M1 2 Window SE Wall 5 (Front -135) 7.2 2.0 1 14.4 0.28 0.18 Insect Screen (default) V1 Window SE Wall 5 (Front -135) 6.3 2.0 1 12.6 0.28 0.18 Insect Screen (default) W2 Window SW Wall 5 (Left -225) 4.9 3.0 1 14.7 0.28 0.18 Insect Screen (default) W1 Window SW Wall 5 (Left -225) 6.0 3.0 1 18.0 0.28 1 0.18 Insect Screen (default) Registration Number: 215-N6343967C-000000000-0000 Registration Date/Time: 2016-04-07 11:58:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03092016-744 Report Generated at: 2016-04-07 11:45:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Club 23B Calculation Date/Time: 11:43, Thu, Apr 07, 2016 Calculation Description: -Title 24 Analysis Input File Name: Madison Club 23B-Kristi Hanson-15.xml CF1 R-P§F-01 Page 8 of 16 23 Window SW Wall 5 (Left -225) 10.8 9.0 1 97.2 0.32 0.24 Insect Screen (default) U2 Window SW Wall 5 (Left -225) 8.7 3.0 1 26.1 0.28 0.18 Insect Screen (default) U1 Window SW Wall 5 (Left -225) 6.3 3.0 1 18.9 0.28 0.18 Insect Screen (default) Ti Window NW Wall 5 (Back -315) 8.9 2.0 1 17.8 0.28 0.18 Insect Screen (default) DOORS 01 02 03 04 Name Side of Building Area (ft) U -factor 26 SE Wall 20.1 0.50 'R 0 V Registration Number: 215-N6343967C-000000000-0000 Registration Date/Time: 2016-04-07 11:58:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03092016-744 Report Generated at: 2016-04-07 11:45:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Club 23B Calculation Date/Time: 11:43, Thu, Apr 07, 2016 Calculation Description: Title 24 Analysis Input File Name: Madison Club 236-Kristi Hanson-15.xml CF1 R -PRF -01 Page 9 of 16 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up DistL Bot Up Depth Top Up Dist R Bot Up K3 10 0.1 10 10 0 0 0 0 0 0 0 0 0 17 10 0.1 10 10 0 0 0 0 0 0 0 0 0 K2 10 0.1 10 10 0 0 0 0 0 0 0 0 0 12 10 0.1 10 10 0 0 0 0 0 0 0 0 0 K32 10 0.1 10 10 0 0 0 0 0 0 0 0 0 11 10 0.1 10 10 0 0 0 0 0 0 0 0 0 J2 10 0.1 10 10 0 0 0 0 0 0 0 0 0 11 10 0.1 10 10 0 0 0 0 0 0 0 0 0 H1 10 0.1 10 10 0 0 0 0 0 0 0 0 0 10 10 0.1 10 10 0 0 0 0 0 0 0 0 0 G2 10 0.1 �_ 10 ,. 10 r _.50 ,_ 0 _ 01, 0 0 0 0 0 0 G3 10 - .�0.1 10- X10 - 0 0'� ` 0 0 0 0 0 0 08 ,1 0, < " `0.1 �.'� _ 10 ,1 10-_ 0 . Or, „ 0 i 0:--j 0 0 0 0 0 07 18 `,`0.,1 i. 18 - ---jt18 t- a 0 ": f-0 lk J l- 0'-, 0r2 0 0 0 0 0 G1 18 0"! 18 F18— ' 0 "0 0— w 0` 0 0 0 0 0 B1 10 0.1 10 10 0 0 0 0 0 0 0 0 0 A4 10 0.1 10 10 0 0 0 0 0 0 0 0 0 A5 10 0.1 10 10 0 0 0 0 0 0 0 0 0 01 10 0.1 10 10 0 0 0 0 0 0 0 0 0 A3 10 0.1 10 10 0 0 0 0 0 0 0 0 0 Al 10 0.1 10 10 0 0 0 0 0 0 0 0 0 A2 10 0.1 10 10 0 0 0 0 0 0 0 0 0 F5 18 0.1 18 18 0 0 0 0 0 0 0 0 0 F6 18 0.1 18 18 0 0 0 0 0 0 0 0 0 06 18 0.1 18 18 0 0 0 0 0 0 0 0 0 F4 18 0.1 18 18 0 0 0 0 0 0 0 0 0 F1 18 0.1 18 18 0 0 0 0 0 0 0 0 0 21 100.1 10 10. 0 0 0 0 0 0 0 0 0 Registration Number: 215-N6343967C-000000000-0000 Registration Date/Time: 2016-04-07 11:58:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03092016-744 Report Generated at: 2016-04-07 11:45:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Club 23B Calculation DateMme: 11:43, Thu, Apr 07, 2016 Calculation Description: Title 24 Analysis Input File Name: Madison Club 236-Kristi Hanson-15.xm1 CF1 R-P1RF-01 ' Page 10 of 16 Registration Number: 215-N6343967C-000000000.0000 Registration Date/Time: 2016-04-07 11:58:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03092016-744 Report Generated at: 2016-04-07 11:45:48 ����0000�0�00 0�00000000�00 Registration Number: 215-N6343967C-000000000.0000 Registration Date/Time: 2016-04-07 11:58:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03092016-744 Report Generated at: 2016-04-07 11:45:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Club 23B Calculation Date/Time: 11:43, Thu, Apr 07, 2016 Calculation Description: Title 24 Analysis Input File Name: Madison Club 236-Kristi Hansbn-15.xm1 CF1 R -PRF -01 Page 11 of 16 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 02 03 04 05 Total Cavity Winter Design Name Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers off nook dining 1621 206 None 0.8 No • Cavity/Frame: no insul. /2x4 Top Chrd great entry 1659 106 2x4 Top Chord of Roof Truss @ 24 0.8 No Roof Deck: Wood Siding/sheathing/decking Attic Roofoff nook dining Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) guest living 1413 190 None 0.8 No • Inside Finish: Gypsum Board Ceilings (below Cavity/ Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-21 / 2x6 • Exterior Finish: Wood R-21 Wall (W.21.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.066 Siding/sheathing/decking • Cavity/Frame: no insul. /2x4 Top Chrd Roofgreat 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic entry Attic Roofs/, , Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) Cavity / Frame: no insul. / 2x4 Top Chrd - 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofmasterguest Attic Roofs _ Wood Framed Ceiling fin: O.0 -:z� r= ,--:i rr z,� none, 0.644 Roofing: Light Roof (Asphalt Shingle) 2x4 Top Chord Roof Truss @24 J Cavity/Frame: no insul. /2x4 Top Chrd Roof Deck: of it �`-' `in. L' 4 i �� , l Wood Siding/sheathing/decking Attic Roofguest living Attic Roofs ,Wood Framed Ceiling' O.C: `' Pnone 0.644 Roofing: Light Roof (Asphalt Shingle) �.J V I U), z i i Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roof2nd master Attic Roofs Wood Framed Ceiling I in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft) Perimeter (ft) Edge Insul. R -value & Depth Carpeted Fraction Heated Covered Slab off nook dining 1621 206 None 0.8 No Covered Slab 2 great entry 1659 106 None 0.8 No Covered Slab 3 masterguest 1781 115 None 0.8 No Covered Slab 4 guest living 1413 190 None 0.8 No BUILDING ENVELOPE - HERS VERIFICATION Ot 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required Registration Number: 215-N6343967C-000000000-0000 Registration Date/Time: 2016-04-07 11:58:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-03092016-744 Report Generated at: 2016-04-07 11:45:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Club 23B Calculation Date/Time: 11:43, Thu, Apr 07, 2016 Calculation Description: Title 24 Analysis Input File Name: Madison Club 23B-Kristi Hanson-15.xml CF1 R-P14F-01 Page 12 of 16 WATER HEATING SYSTEMS 01 02 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 - 1/3 DHW Pipe Insulation, All Lines DHW Heater 1 3 .0% WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.66 40000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name 1 Pipe Insulation f. Parallel Piping- - Compact Distribution Point -of Use Recirculation Control Central DHW Distribution DHW Sys 1 - 1/3 f HVAC Fan 1 Air Distribution System 1 Distribution System 1:HVAC Fan 1:1 --- --- SPACE CONDITIONING SYSTEMS i ` '' �'^ ial✓f ''� T3 01 02 - 03 - 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Cooling Component 1:Heating Component 1:Air Other Heating and Cooling Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 Distribution System 1:HVAC Fan 1:1 System Cooling Component 2:Heating Component 2:Air Other Heating and Cooling Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2 Distribution System 2:HVAC Fan 2:1 System Cooling Component 3:Heating Component 3:Air Other Heating and Cooling Heating Component 3 Cooling Component 3 HVAC Fan 3 Air Distribution System 3 Distribution System 3:HVAC Fan 3:1 System Cooling Component 4:Heating Component 4:Air Other Heating and Cooling Heating Component 4 Cooling Component 4 HVAC Fan 4 Air Distribution System 4 Distribution System 4:HVAC Fan 4:1 System Cooling Component 5:Heating Component 5:Air Other Heating and Cooling Heating Component 5 Cooling Component 5 HVAC Fan 5 Air Distribution System 5 Distribution System 5:HVAC Fan 5:1 System Registration Number: 215-N6343967C-000000000-0000 Registration Date/Time: 2016-04-07 11:58:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03092016-744 Report Generated at: 2016-04-07 11:45:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Club 23B Calculation Date/Time: 11:43, Thu, Apr 07, 2016 Calculation Description: Title 24 Analysis Input File Name: Madison Club 2313-Kristi Hanson-15.xml CFI R-P'hF-01 ' Page 13 of 16 HVAC - HEATING UNIT TYPES 01 02 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 2 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 3 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 4 CntrlFurnace - Fuel -fired central furnace 80 AFUE Heating Component 5 CntrlFurnace - Fuel -fired central furnace 80 AFUE HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 Name Verified Airflow Efficlency Verified EER Multi -speed Verified Refrigerant Charge Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond 13 16.5 Not Zonal Single Speed Cooling Component Required 350 Required Required Required Cooling Component 4 -hers -cool 1 -hers -cool Cooling Component 2 SplitAirCond f { 13-- ,- - .- 16.5 — f - Not Zonal Single Speed Cooling Component 2 -hers -cool Required Required Required Cooling Component 3 % SplitAirCond f. i 13 =� I ` 16.5 �• Not Zonal Single Speed Cooling Component , 3 -hers -cool Cooling Component 4 SplitAirCond. i y ' +� f: '6.5° Not Zonate Single Speed Cooling Component ` _13 ; - 4 -hers -cool Cooling Component 5 SplitAirCond 13 16.5 Not Zonal Single Speed Cooling Component 5 -hers -cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1 -hers -cool Required 350 Required Required Required Cooling Component 2 -hers -cool Required 350 Required Required Required Cooling Component 3 -hers -cool Required 350 Required Required Required Cooling Component 4 -hers -cool Required 350 Required Required Required Cooling Component 5 -hers -cool Required 350 Required Required Required Registration Number: 215-N6343967C-000000000-0000 Registration Date/Time: 2016-04-07 11:58:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03092016-744 Report Generated at: 2016-04-07 11:45:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Club 23B Calculation Date/Time: 11:43, Thu, Apr 07, 2016 Calculation Description: Title 24 Analysis Input File Name: Madison Club 236-Kristi Hanson-15.xml CF1 R-PIIF-01 Page 14 of 16 HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R -value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 'Not Required Not Required --- Air Distribution System 2 -hers -dist ' Required 6.0 ` 1 -hers -dist Air Distribution System 2 DuctsAttic Sealed and tested 8 Attic None Air Distribution System Not Requimcl "" " NotRequiredl _:Not Required Not Required - Air Distribution System 4 -hers -dist 2 -hers -dist Air Distribution System 3 DuctsAttic Sealed and tested 8 Attic None Air Distribution System Required 6.0 Not Required Not Required Not Required Not Required 3 -hers -dist Air Distribution System 4 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 4 -hers -dist Air Distribution System 5 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 5 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage . Verification Duct Leakage Target (%)< Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handier Air Distribution System 1 -hers -dist Required '6.0 Not Required Not Required 'Not Required Not Required --- Air Distribution System 2 -hers -dist ' Required 6.0 ` Not Required . �_NotRequired Not Required Not Required --- Air Distribution System 3 -hers -dist Required - 6.0-' =- Not Requimcl "" " NotRequiredl _:Not Required Not Required - Air Distribution System 4 -hers -dist Required 6.0 Not Required Not Required Not Required Not Required --- Air Distribution System 5 -hers -dist Required 6.0 Not Required Not Required Not Required Not Required --- HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.58 HVAC Fan 2 -hers -fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.58 HVAC Fan 3 -hers -fan HVAC Fan 4 Single Speed PSC Furnace Fan 0.58 HVAC Fan 4 -hers -fan HVAC Fan 5 Single Speed PSC Furnace Fan 0.58 HVAC Fan 5 -hers -fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Registration Number: 215-N6343967C-000000000-0000 Registration Date/Time: 2016-04-07 11:58:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03092016-744 - Report Generated at: 2016-04-07 11:45:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE -METHOD Project Name: Madison Club 23B Calculation Date/Time: 11:43, Thu, Apr 07, 2016 Calculation Description: Title 24 Analysis _ Input File Name: Madison Club 2313-Kristi Hanson- 15.xml CF1 R -PRF -01 Page 15 of 16 Name Verified Fan Waft Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Required 0.58 HVAC Fan 2 -hers -fan Required 0.58 HVAC Fan 3 -hers -fan" Required 0.58 HVAC Fan 4 -hers -fan Required 0.58 HVAC Fan 5 -hers -fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt .200.44 0.25 Default 0 Required COOLING VENTILATION ,' i� , 01 _ �. 02 03 04 05 Name Cooling Vent CFM Cooling Vent Watts/CFM Total Watts Number of Fans WH Fan 1 61 �^' i' � -' , n)'0.52459( �� 32 1 WH Fan 2 + �61 �r j l� i l� 0.52459 --'�) ': 1 C i s 32 1 WH Fan 3 61. '-r . es L -� ,� `i 0.52459;—` WH Fan 4 r 61,j—� ; y f S 11 0.524,59 V j L I• 17- j�j 32 1 WH Fan 5 61 0.52459 32 1 PROJECT NOTES The Madison Club 23B Registration Number: 215-N6343967C-000000000-0000 Registration Date/Time: 2016-04-07 11:58:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-03092016-744 Report Generated at: 2016-04-07 11:45:48 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Club 23B Calculation Date/Time: 11:43, Thu, Apr 07, 2016 Calculation Description: Title 24 Analysis Input File Name: Madison Club 236=Kristi Hanson-15.xml CF1 R -PRF -01 Page 16 of 16 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Tim Scott Company: Signature Date: Scott Design and Title 24, Inc. 2016-04-07 11:58:25 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify•that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. ` 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: - (:{ i Responsible Designer Signature: -, T Tim Scott Company: ` ,� 9 --- r Date Signed: Scott Design and Title 24, Inc. 2016-04-07 11:58:25 Address: License: 77085 Michigan Drive NA City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-N6343967C-000000000-0006 Registration Date/Time: 2016-04-07 11:58:25 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF113-03092016-744 Report Generated at: 2016-04-07 11:45:48 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Madison Club 23B Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 4/7/2016 Project Address 81-382 Amundson Ave. La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 8,044 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status Roof Wood Framed Attic R 38 6,945 New Wall Wood Framed R 21 9,480 New Door Opaque Door no insulation 20 New Slab Unheated Slab -on -Grade no insulation 6,474 Perim = 617' New Demising Wood Framed R 13 3,280 New FENESTRATION Orientation Area ft2 I Total Area: 3,276 Glazing Percentage: 40.7 % U -Fac SHGC Overhang Sidefins New/Altered Average U -Factor: Exterior Shades 0.30 Status Right (NE) 255.0 0.280 0.18 10.0 none Bug Screen New Right (NE) 287.0 0.320 0.24 10.0 none Bug Screen New Front (SE) 309.1 0.280 0.18 10.0 none Bug Screen New Left (SW) 411.9 0.280 0.18 10.0 none Bug Screen New Left (SW) 255.0 0.320 0.24 10.0 none Bug Screen New Rear (NM 403.0 0.320 0.24 18.0 none Bug Screen New Rear (NW) 214.3 0.280 0.18 18.0 none Bug Screen New Right (NE) 262.4 0.280 0.18 none none Bug Screen New Front (SE) 85.0 0.320 0.24 10.0 none Bug Screen New Front (SE) 92.2 0.280 0.18 none none Bug Screen New Front (SE) 85.0 0.320 0.24 none none Bug Screen New Left (SW) 21.5 0.280 0.18 none none Bug Screen New Rear (NW) 78.0 0.320 0.24 none none Bug Screen New Rear (NM 68.4 0.280 0.18 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R -Value Status HVAC 1 off kit nook Ducted Ducted Attic 8.0 New HVAC 2 grt enry Ducted Ducted Attic 8.0 New HVAC 3 mstr gest Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 3 Small Storage Gas 50 0.66 All Pipes Ins New Ener Pro 6.7 by Ener Soft User Number: 6712 RunCode: 2016-04-07711:47:24 /D: Pae 19 of 49 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Madison Club 23B Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 4/7/2016 Project Address 81-382 Amundson Ave. La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 8,044 Addition n/a # of Units Fl INSULATION Construction Type Area Cavity (ft) Special Features Status FENESTRATION Total Area: 3,276 Glazing Percentage: 40.7 % New/Altered Average U -Factor: Orientation Area(ft) U -Fac SHGC Overhang Sidefins Exterior Shades 0.30 Status Rear (NM 70.4 0.280 0.18 10.0 none Bug Screen New Rear (NIA 77.0 0.320 0.24 10.0 none Bug Screen New Right (NE) 36.0 0.280 0.18 6.0 none Bug Screen New Right (NE) 90.0 0.320 0.24 none none Bug Screen New Left (Sly 77.7 0.280 0.18 6.0 none Bug Screen New Left (St9 97.2 0.320 0.24 6.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New 1 Central Furnace 80% AFUE Split Air Conditioner 16.5 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC 4 gest liv Ducted Ducted Attic 8.0 New HVAC 5 2nd Ducted Ducted Attic 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ener Pro 6.7 by Ener Soft User Number: 6712 RunCode: 2016-04-07T11:47:24 ID: Page 20 of 49 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. Exceptions may apply. Review the respective code section for more information. Building Envelope Measures: §110.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § 110.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of § 10-111 (a). § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § 110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § 110.8(i): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the installation of a cool roof is specified on the CF1R. § 110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFIR. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a § 150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. § 150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. § 150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - factor). § 150.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior § 150.0(g)1: walls, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II § 150.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of § 150.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). § 150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8 150.0 § (q)' Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U- factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: § 150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is e ui ed with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. §150.0(e)1C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: § 110.0-§ 110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. § 110.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of § 1 10.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- §110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. § 150.0(h) 1: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in § 150.0(h)2. § 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. § 150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c). §150.00)1 A: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150.00)1B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R- 12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system § 150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. § 150.0(j)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. 2013 Low -Rise Residential Mandatory Measures Summary 150.00)2C: Pipe for cooling system lines shall be insulated as specified in § 150.00)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. § 150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For § 150.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I § 150.00)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the § 150.0(n)1: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5. §150.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed §150.0(m)1: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '/< inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints § 150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other re uirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. §150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. §150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not § 150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be § 150.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of §150.0 m 12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The § 150.0(m)13: space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, § 150.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of> 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of § 150.0(o): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. §150.0(o)lA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. 2013 ,Low -Rise Residential Mandatory Measures Summary 110.4(b)1: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § 110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro- grammed to run only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. § I50.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. § 150.0(k)IA: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § 150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-13, as applicable. §150.0(k)IB: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with §150.0(k)IC: § 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. §150.0(k)1D: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no §150.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. §150.0(k)IF: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of § 150.0(k). § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. § 150.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § 150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k). § 150.0(k)2F: Lighting controls comply with applicable requirements of § 110.9. An Energy Management Control System (FMCS) may be used to comply with dimmer requirements if: it functions as a dimmer § 150.0(k)2G: according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. An Energy Management Control System (FMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if: it § 150.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. § 150.0(k)2I: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § I50.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. § 150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. § 150.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. § 150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. § I50.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing § 150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and § 150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 2013 ,Low -Rise Residential Mandatory Measures Summary a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically tum the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with § 110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically tum the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the § 150.0(k)9B: following requirements: i. Shall comply with § 150.0(k)9A; or ii. Shall comply with the applicable requirements in §110.9, §130.0, § 130.2, § 130.4, § 140.7 and §141.0. § 150.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0. § 150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0. §150.0(k)10: Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined according to § 13 0.0(c). §150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in § 110.9, § 130.0, § 130. 1, § 130.4, § 140.6, and § 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of § 150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: § 150.0(k)1213: i. Comply with the applicable requirements in § 110.9, § 130.0, § 130. 1, § 140.6 and § 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a § 110.10(a)1: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of § 110.10 through § 110.10 e . § 110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for § 110.10(b)1: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit § l 10.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c) shall be provided to the occupant. § 110.10(e)1: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a §110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric". d-IVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Madison Club 23B Date 4/7/2016 System Name HVAC 1 off kit nook Floor Area 1,621 ENGINEERING CHECKS SYSTEM LOAD Number of System 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL CFM 3,115 243 COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 110,000 33,156 2,867 721 35,004 Total Output Btuh 110,000 0 Output Btuh/s ft 67.9 1,562 1,336 Cooling System .01 0 Output per System 58,000 10,678 2,750 243 11,741 Total Output Btuh 58,000 1,489 1,562 1 48,448 5,617 -1,489 Total Output ons 4.8 1,336 Total Output Btuh/s ft 35.8 Total Output s ft/Ton 335.4 47,928 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 carrier 24ANB760/58MVB110- 36,577 15,187 110,000 Airflow cfm/s ft 1.23 110,000 Jan 1 AM Airflow cfm/Ton 413.8 Outside Air % 12.2 % Total Adjusted System Output 36,577 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 15,187 Aug 3 PM Outside Air cfm/s ft 0.15 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS jAirstream Temperatures at Time of Heating Peak 26 OF 66 OF Outside Air 243 cfm Supply Fan 2,000 cfm 71 OF 67 OF 118 OF Heating Coil ti•-.i-�..� 118 OF "OO,M 72 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 76/65°F 76/65°F 59/58°F Outside Air O 243 cfm Supply Fan Cooling Coil 2,000 cfm 71 /63°F 60 / 59 OF Q 67.0% ROOM 70/63°F EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2016-04-07T11:47:24 ID: Page 25 of 49 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Madison Club 23B Date 4/7/2016 System Name HVAC 2 grt enry Floor Area 1,659 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL CFM 2,180 249 COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Out ut per System 110,000 27,144 2,934 512 24,951 Total Output Btuh 110,000 0 Output Btuh/s ft 66.3 1,279 952 Cooling System 0 Output per System 58,000 10,964 3,550 249 12,064 Total Output Btuh 58,000 1,489 6,484 -1,489 Total Output Tons 4.8 1,279 952 Total Output Btuhls ft 35.0 Total Output s ft/Ton 343.2 1 42,155 37,430 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ANB760/58MVB110 39,916 11,204 110,000 Airflow cfm/s ft 1.21 Airflow cfm/Ton 413.8 110,000 Jan 1 AM Outside Air % 12.4% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 1 39,916 11,204 Aug 3 PM Outside Air cfm/s ft 0.15 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 66 OF Outside Air Ar 249 cfm Supply Fan 2,000 cfm 72 OF 67 OF 118 OF Heating Coil ��_...� 118 `F ROOM 72 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 76/64°F 76/65°F 58/57°F - Outside Air Ar Im 249 cfm Supply Fan Cooling Coil 2,000 cfm 71 /62°F _I 58 / 57 OF p 63.1 % ROOM 70/62°F I . EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-04-07T11:47:24 ID: Page 26 of 49 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Madison Club 23B Date 4/7/2016 System Name HVAC 3 mstr gest Floor Area 1,781 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL CFM 1,819 267 COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 110,000 22,257 3,150 436 21,112 Total Output Btuh 110,000 0 Output Btuh/s ft 61.8 1,049 806 Cooling System 0 0 Output per System 58,000 11,801 3,633 267 12,970 Total Output Btuh 58,000 1,489 6,783 -1,489 Total Output Tons 4.8 1,049 806 Total Output Btuh/s ft 32.6 Total Output s ftiTon 368.5 1 37,644 34,205 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ANB760/58MVB110 39,853 11,521 110,000 110,000 Jan 1 AM Airflow cfm/s ft 1.12 Airflow cfmrron 413.8 Outside Alr % 13-4% Total Adjusted System Output 39,853 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 11,521 Aug 3 PM Outside Air cfm/s ft 0.15 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 66 OF 66 OF 118 OF Ct Outside Air 267 cfm . Supply Fan Heating Coil 2,000 cfm 72 OF .—.. �.... 118 OF I,RQOM 72 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 76/65°F 77/65°F 58/57°F 0' Outside Air Ar 267 cfm Supply Fan Cooling Coil 2,000 cfm 70/62°F 59 / 57 OF 64.0% ROOM 70/62°F EnergyPro 6.7 by EnergySoft User Number., 6712 RunCode: 2016-04-07T11:47:24 ID: Page 27 of 49 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Madison Club 23B Date 4/7/2016 System Name HVAC 4 gest liv Floor Area 1,413 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,828 Return Vented Lighting Return Air Ducts Return Fan Ventilation 212 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 110,000 24,476 2,499 561 27,813 Total Output Btuh 110,000 0 Output Btuh/s ft 77.8 1,153 1,062 Cooling System 0 0 Output per System 58,000 9,351 3,369 212 10,263 Total Output Btuh 58,000 1,489 1,153 1 37,623 5,868 -1,489 Total Output Tons 4.8 1,062 Total Output Btuh/s ft 41.0 Total Output s ft/Ton 292.3 38,711 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ANB760/58MVB110 39,927 10,543 110,000 Airflow cfm/s ft 1.42 Airflow cfm/Ton 413.8 Outside Air % 10.6 % Total Adjusted System Output 39,927 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 10,543 Aug 3 PM 110,000 Outside Air cfm/s ft 0.15 Note: values above given at ARI conditions I Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 67 OF 67 OF 119 OF Outside Air 212 cfm Supply Fan Heating Coil 2,000 cfm 72 OF 119 OF ROOM In 72 OF COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112/78°F 75/63°F 76/64°F 57/56°F a - .�., _._. Outside Air -4 r O �I�Ip 212 cfm Supply Fan Cooling Coil 57 / 56 OF 2,000 cfm 61.0% ROOM 71 / 61 OF 70 / 61 OF EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-04-07711:47:24 ID: Page 28 of 49 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Madison Club 23B Date 4/7/2016 System Name HVAC 5 2nd Floor Area 1,570 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,507 Return Vented Lighting Return Air Ducts Return Fan Ventilation 236 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 110,000 19,641 2,777 343 16,916 Total Output Btuh 110,000 0 Output Btuh/s ft 70.1 925 646 Cooling System 0 0 Output per System 58,000 10,417 3,528 236 11,453 Total Output Btuh 58,000 1,489 925 33,398 6,305 -1,489 Total Output Tons 4.8 646 Total Output Btuh/s ft 36.9 Total Output s ft/Ton 324.8 E28172 Air System CFM per System 2,000 HVAC EQUIPMENT SELECTION Airflow cfm 2,000 Carrier 24ANB760/58MVB110 39,816 11,009 110,000 Airflow cfm/s ft 1.27 Airflow cfmfron 413.8 Outside Air % 11.8% Total Adjusted System Output 39,816 11,009 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM 110,000 Jan 1 AM Outside Air cfm/s ft 0.15 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 66 OF Outside Air 236 cfm Supply Fan 2,000 cfm 72 OF 67 OF 119 OF �,....1� Heating Coil 118 ,F Ft00M 72 OF L! COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time ofPeak .Cooling 112/78°F 75/64°F 76/64°F 57/56°F Ct ��Outside Air Ar 236 cfm Supply Fan Cooling Coil 58 / 57 OF 2,000 cfm 62.2% ROOM Fa 70/62°F 70/61 OF EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-04-07T11:47:24 ID: Page 29 of 49 ROOM LOAD SUMMARY Project Name Date Madison Club 238 4/7/2016 System Name Floor Area HVAC 1 off kit nook 1,621 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible I Latent CFM Sensible I Latent CFM I Sensible off nook dining Office Kitchen Nook & Di 1 1 3,1151 33,1561 Z 867 3,1151 33,1561 2,867 7211 35,004 PAGE TOTAL TOTAL* 3,115 33,156 2,8671 721 35,004 3,115 33,156 2,8671 721 35,0041 * Total includes ventilation load for zonal systems. EnergyPro 6.7 by Ener Soft User Number: 6712 RunCode: 2016-04-07T11:47:24 ID: Page 30 of 49 ROOM LOAD SUMMARY Project Name Date Madison Club 238 4/7/2016 System Name Floor Area HVAC 2 grt enry 1,659 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible I Latent CFM Sensible Latent I CFM I Sensible great entry Great Room and Entry 1 1 1 2,1801 27,1441 2,934 2,1801 27,1441 2,9341 5121 24,951 PAGE TOTAL TOTAL* 2,180 27,144 2,9341 512 24,951 F2,18OF 27,144 2,9341 512 24,951 * Total includes ventilation load for zonal systems. EnetigyPro 6.7 by Eneng Soft User Number: 6712 RunCode: 2016-04-07711:47:24 ID: Page 31 of 49 ROOM LOAD SUMMARY Project Name Date Madison Club 238 4/7/2016 HVAC 3 mstr gest 1,781 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM I Sensible I Latent CFM I Sensible I Latent CFM I Sensible masterguest Guest Master Bedroom I 1 1 1,8191 22,2571 3,150 1,8191 22,2571 3,150 4361 21,112 PAGE TOTAL TOTAL * 1,819 22,257 3,150 436 21,112 1,819 22,257 3,150 436 21,112 * Total includes ventilation load for zonal systems. Ener Pro 6.7 by Ener Soft User Number. 6712 RunCode: 2016-04-07T11:47:24 ID: Page 32 of 49 ROOM LOAD SUMMARY Project Name Date Madison Club 238 4/7/2016 System Name Floor Area HVAC 4 gest liv 1,413 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name I Mult. I CFM I Sensible I Latent CFM I Sensible I Latent CFM I Sensible guest living I Guest Living Area I 1 1 1,8281 24,4761 2,4991 1,8281 24,4761 2,499 5611 27,813 PAGE TOTAL TOTAL` 1,828 24,476 2,499 561 27,813 1,828 24,476 2,499 561 27,813 Total includes ventilation load for zonal systems. Ener Pro 6.7 by Ener Soft User Number: 6712 RunCode: 2016-04-07711:47:24 ID: Page 33 of 49 ROOM LOAD SUMMARY Project Name Date Madison Club 238 4/7/2016 System Name Floor Area HVAC 5 2nd 1,570 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. I CFM Sensible I Latent CFM I Sensible Latent CFM Sensible 2nd master 2nd Floor Master Bedrood 1 1,507 19,641 2,777 1,507 19,641 2,777 3431 16,916 PAGE TOTAL TOTAL* 1,507 19,641 2,777 343 16,916 1,5071 19,6411 2,7771 343 16,916 * Total includes ventilation load for zonal systems. Ener Pro 6.7 by Ener Soft User Number. 6712 RunCode: 2016-04-07711:47:24 ID: Page 34 of 49 ROOM HEATING PEAK LOADS Project Name Madison Club 23B Date 4/7/2016 ROOM INFORMATION DESIGN CONDITIONS Room Name Office Kitchen Nook & Dining Floor Area 1,621.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U-Value 522.0 X 0.0260 2,137.8 X 0.0690 584.1 X 0.2800 570.0 X 0.3200 20.1 X 0.5000 perim = 206.0 X 0.7300 856.0 X 0.1020 X X X X X X X X X X X X X X X X X X X X X X X X through an interior surface to another room X 1,621 X 9.00 X 0.361 Area Ceiling Height ACH X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F = c = = 0 = 0 = = = = = = = = = = = = = = = = = = = = 46 Btu/hr R-38 Roof Attic 46 624 R-21 Wall (W.21.2x6.16) 46 6,785 FIX door window slider. 28.18 46 7,523 OPP window door slider .32.24 46 8,390 Wood Door 46 462 Slab-On-Grade 46 6,917 'R-13 Wall 0 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction Page Total /60] X AT 30,703 = 4,301 TOTAL HOURLY HEAT LOSS FOR ROOM 35,004 EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-04-07T11:47:24 ID: Page 35 of 49 ROOM HEATING PEAK LOADS Project Name Madison Club 238 Date 4/7/2016 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Room and Entry Floor Area 1,659.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U-Value AT OF X 0.0260 X 46 X 0.0690 X 46 X 0.2800 X 46 X 0.3200 X 46 X 0.7300 X 46 X 0.1020 X 0 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to another room Page Total 9.00 X 0.361 /60] X Ceiling Height ACH AT Btu/hr = 1,984 = 4,698 = 6,054 = 4,254 = 3,559 = 0 = = = = = = = = = = = = = = = = = = = = = = = 20,549 46 = 4,402 R-38 Roof Attic 1,659.0 R-21 Wall (W.21.2x6.16) 1,480.0 FIX door window slider. 28.18 470.0 OPP window door slider .32.24 289.0 Slab-On-Grade perim = 106.0 'R-13 Wall 511.0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,659 X Area TOTAL HOURLY HEAT LOSS FOR ROOM 24,951 EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-04-07T11:47:24 ID: Page 36 of 49 ROOM HEATING PEAK LOADS Project Name Madison Club 23B Date 4/7/2016 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Master Bedroom Floor Area 1,781.0 ftZ Indoor Dry Bulb Tem erature 72 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area R-38 Roof Attic 1,781.0 R-21 Wall (W.21.2x6.16) 1,498.5 FIX door window slider. 28.18 251.5 OPP window door slider .32.24 163.0 Slab -On -Grade perim = 115.0 *R-13 Wall 712.0 Items shown with an asterisk (') denote conduction through an interior surface Infiltration:[ 1.00 X 1.064 X 1,781 X Schedule Air Sensible Area Fraction X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value AT'F 0.0260 X 46 = 0.0690 X 46 = 0.2800 X 46 c 0.3200 X 46 = 0.7300 X 46 = 0.1020 X 0 = X = X = X = X = X = X = X = X = X X = X = X = X = X = X = X = X = X X = X = X = X = X = X = X = another room Page Total 9.00 X 0.361 /60] X 46 Height ACH AT Btu/hr 2,130 4,756 3,239 Z399 3,862 0 16,387 = 4,725 TOTAL HOURLY HEAT LOSS FOR ROOM 21,112 EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-04-07T11:47:24 ID: Page 37 of 49 ROOM HEATING PEAK LOADS Project Name Madison Club 23B Date 4/7/2016 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Living Area Floor Area 1,413.0 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value 0.0260 X 0.0690 X 0.3200 X 0.2800 X 0.7300 X 0.1020 X X X X X X X X X X X X X X X X X X X X X X X X X X another room 9.00 X 0.361 Height ACH AT °F c = = c 0 0 = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr R-38 Roof Attic 1,413.0 46 1,690 R-21 Wall (W.21.2x6.16) Z449.2 46 7,774 OPP window door slider .32.24 248.0 46 3,651 FIX door window slider. 28.18 354.8 46 4,570 Slab -On -Grade perim = 190.0 46 6,380 *R-13 Wall 745.0 0 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,413 X Area Page Total /60] X AT 24,064 = 3,749 TOTAL HOURLY HEAT LOSS FOR ROOM 27,813 EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-04-07T11:47:24 ID: Page 38 of 49 ROOM HEATING PEAK LOADS Project Name Madison Club 23B Date 4/7/2016 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Master Bedroom Floor Area 1,570.0 ft2 Indoor Dry Bulb Temperature 72 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area R-38 Roof Attic 1,570.0 X R-21 Wall (W.21.2x6.16) 1,914.3 X FIX door window slider. 28.18 158.5 X OPP window door slider .32.24 187.2 X 'R-13 Wall 456.0 X X X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (') denote conduction through an interior surface to Infiltration:[ 1.00 X 1.064 X 1,570 X Schedule Air Sensible Area Ceiling Fraction U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F 46 c 46 = Btu/hr 0.0260 1,878 0.0690 6,076 0.2800 46 = 2,041 0.3200 46 = 2,756 0.1020 0 = 0 = = = = = = = = = = = = = = = = = = = = = = = another room 9.00 X 0.361 Height ACH Page Total /60] X 46 AT 12,751 = 4,166 TOTAL HOURLY HEAT LOSS FOR ROOM 16,916 EnergyPro 6.7 by EnergySoft User Number. 6712 RunCode: 2016-04-07T11:47:24 ID: Page 39 of 49 RESIDENTIAL ROOM COOLING LOAD SUMMARY Madison Club 23B ROOM INFORMATION Room Name Floor Area Indoor Dry Bulb Tem en Opaque Surfaces R-38 Roof Attic R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) Wood Door R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) *R-13 Wall DESIGN CONDITIONS Office Kitchen Nook & Dining Outdoor Dry Bulb Temperature 1,621.0 ft2 Outdoor Wet Bulb Temperature 70 °F Outdoor Dailv Ranee: Orientation (NE) (SE) (SE) (SW) (NW) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 522.0 0.0260 56.0 493.0 0.0690 29.0 334.9 0.0690 31.0 20.1 0.5000 31.0 1,148.7 0.0690 31.0 161.2 0.0690 30.2 856.0 0.1020 0.0 16.4 121.0 15.3 0.0 20.8 16.0 12.3 0.0 Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration K3 17 K2 12 K3 11 J2 J1 H1 Orientation (NE) (NE) (NE) (SE) (SW) (SW) (S W) (SW) (S W) Shaded Unshaded 4/7/2016 112 OF 78 OF 34 OF Btu/hr 986 716 312 1 3361 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF c = = = = = = = = 0.0 12.3 110.0 18.1 0.0 15.3 116.0 23.0 0.0 12.3 113.0 18.1 109.0 12.3 0.0 16.4 110.0 12.3 0.0 16.4 121.0 15.3 0.0 20.8 16.0 12.3 0.0 16.4 16.0 12.3 0.0 16.4 21.2 12.3 0.0 16.4 Page Total Btu/hr 1,987 2,671 2,042 1,338 1,351 1,852 196 1 1961 11, Internal Gain Btu/hr Occupants 4 9 Occupants X 245 Btuh/occ. = 1,191 Equipment 1,621 Floor Area X 0.50 w/sgff = 2,766 Infiltration: 1.064 X 1.27 X 66.86 X 42 = 3,782 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 33,1561 Latent Gain Btu/hr Occupants 4 9 Occupants X 155 Btuh/occ. = 754 Infiltration: 4,771 X 1.27 X 66.86 X 0.00523 = 2,113 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 7541 I EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-04-07711:47:24 ID: Page 40 of 49 1 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Madison Club 238 1 4/7/2016 ROOM INFORMATION DESIGN CONDITIONS Room Name Office Kitchen Nook & Dining Outdoor Dry Bulb Temperature 112 OF Floor Area 1, 621.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 10 (SM 110.0 X 15.3 + 0.0 X 20.8 = 1,684 G2 (SI49 43.5 X 12.3 + 0.0 X 16.4 = 534 G3 (s 149 5.6 X 12.3 + 0.0 X 16.4 = 69 08 IS 149 24.0 X 15.3 + 0.0 X 20.8 = 367 07 (NIA 0.0 X 15.3 + 199.0 X 23.0 = 4,582 G1 (NIAq 0.0 X 12.3 + 39.8 X 18.1 = 719 X + X = X + X = X + X = Page Total 7,95 Internal Gain Btu/hr Occupants 49 Occupants X 245 Btuh/occ. = 1,191 Equipment 1,621 Floor Area X 0.50 w/sgft = 2,766 Infiltration: 1.064 X 1.27 X 66.86 X Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 33,156 Latent Gain Btu/hr Occupants 4 9 Occupants X 155 Btuh/occ. = 754 Infiltration: 4,771 X 1.27 X 66.86 X F 2,113 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 754 Ener Pro 6.7 by EnetiqySoft User Number: 6712 RunCode: 2016-04-07T11:47:24 ID: Page 41 of 49 RESIDENTIAL ROOM COOLING LOAD SUMMARY Madison Club 238 1 4/7/2016 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Room and Entry Outdoor Dry Bulb Temperature 112 °F Floor Area 1,659.0 ft2 Outdoor Wet Bulb Temperature 78 °F Indoor Dry Bulb Temperature 70 OF Outdoor Dailv Ranae: 34 OF Opaque Surfaces R-38 Roof Attic R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W 21.2x6.16) R-21 Wall (W.21.2x6.16) *R-13 Wall Orientation (M (NE) (SE) (SW) (NM Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = c = = = = = = 1,659.0 0.0260 56.0 564.0 0.0690 29.0 155.5 0.0690 31.0 684.0 0.0690 31.0 76.5 0.0690 30.2 511.0 0.1020 0.0 9.2 12.3 0.0 16.4 85.0 15.3 0.0 20.8 17.5 12.3 0.0 Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration F3 F2 B1 A4 A5 01 A3 Al . A2 CAriPntatinn (NE) (NE) (SE) (SE) (SE) (SE) (SE) (SE) (SE) Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = 0.0 12.3 60.0 18.1 0.0 12.3 60.0 18.1 8.3 12.3 0.0 16.4 35.4 12.3 0.0 16.4 9.2 12.3 0.0 16.4 85.0 15.3 0.0 20.8 17.5 12.3 0.0 16.4 35.4 12.3 0.0 16.4 9.3 12.3 0.0 Page Total 1 5,499 Btu/hr 1,084 1,084 102 435 113 1,301 215 435 11 4,8831 Internal Gain Btu/hr Occupants 5 0 Occupants X 245 Btuh/occ. = 1,219 Equipment 1,659 Floor Area X 0.50 w/sgft Infiltration: 1.0e X 1.27 X 68.43 X 42 = C Air Sensible CFM ELA AT 1 TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 27,1441 Latent Gain Btu/hr Occupants 5 0 Occupants X 155 Btuh/occ. = 771 Infiltration: 4, 771 X 1.27 X 68.43 X 0.00523 = 2,163 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 7711 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Madison Club 238 4/7/2016 ROOM INFORMATION DESIGN CONDITIONS Room Name Great Room and Entry Outdoor Dry Bulb Temperature 112 OF Floor Area 1,659.0 ft- Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 °F Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr M1 (SE) 0.01 X 12.3 + 60.4 X 16.4 = 992 F5 (NKq 0.0 X 12.3 + 55.1 X 18.1 = 996 F6 (NM 0.0 X 12.3 + 17.4 X 18.1 = 314 06 (NM 0.0 X 15.3 + 204.0 X 23.0 = 4,697 F4 (NIM 0.0 X 12.3 + 51.0 X 18.1 = 921 F1 (NM 0.0 X 12.3 + 51.0 X 18.1 = 921 X + X = X + X = X + X = Page Total 8,842 Internal Gain Btu/hr Occupants 50 Occupants X 245 Btuh/occ. = 1,219 Equipment 1.659 Floor Area X 0.50 w/sgft = 2,831 Infiltration: 1.064 X 1.27 X 68.43 X 42 = 3,870 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 27,144 Latent Gain Btu/hr Occupants 5.0 Occupants X 155 Btuh/occ. = 771 Infiltration: 4,771 X 1.27 X 68.43 X F7 2,163 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 771 Ener Pro 6.7 by Ener Soft User Number. 6712 RunCode: 2016-04-07T11:47:24 ID: Page 43 of 49 c RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Madison Club 238 4/7/2016 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Master Bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 1, 781.0 ft- Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces R-38 Roof Attic R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) *R-13 Wall Orientation I'm (NE) (SE) (SIM (NM Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,781.0 0.0260 56.0 514.6 0.0690 29.0 471.8 0.0690 31.0 178.5 0.0690 31.0 333.6 0.0690 30.2 712.0 0.1020 0.0 0.0 12.3 19.2 16.4 0.0 15.3 85.0 20.8 0.0 12.3 21.5 Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) I Fanastratinn E1 E2 D3 D2 D1 02 C1 05 E5 Orientation (NE) (NE) (NE) (NE) (SE) (SE) (SW) (NW) (NM Shaded Unshaded Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 12.3 96.0 18.1 0.0 12.3 19.2 18.1 0.0 12.3 5.6 18.1 0.0 12.3 21.6 18.1 0.0 12.3 19.2 16.4 0.0 15.3 85.0 20.8 0.0 12.3 21.5 16.4 0.0 15.3 78.0 23.0 0.0 12.3 15.6 18.1 Page Total Btu/hr 2,5931 1,030 1,009 382 5,710 Btu/hr 1,735 347 101 390 315 1,771 353 1,796 28 7,0901 Internal Gain Btu/hr Occupants 5 3 Occupants X 245 Btuh/occ. = 1,� Equipment 1.781 Floor Area X 0.50 w/sqn = 3,1 Infiltration: 1.064 X 1.27 X 73.46 X 42 = , Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22,257 Latent Gain Btu/hr Occupants 5 3 Occupants X 155 Btuh/occ. = 828 Infiltration: 4,771 X 1.27 X 73.46 X 0.00523 = 2,322 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 828 IEnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-04-07T11:47:24 ID: Page 44 of 49 1 A RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Madison Club 23B 4/7/2016 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Master Bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 1,781.0 ft- Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr E3 (NtM 0.0 X 12.3 + 44.0 X 18.1 = 795 E4 (NK9 0.0 X 12.3 + 8.8 X 18.1 = 159 X + X = X + X = X + X = X + X = X + X = X + X = X + X = Page Total 954 Internal Gain Btu/hr Occupants 53 Occupants X 245 Btuh/occ.=L 1,309 Equipment 1,781 Floor Area X 0.50 w/sgft = 3,039 Infiltration: 1.064 X 1.27 X 73.46 X 42 = 4,155 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 22,257 Latent Gain Btu/hr Occupants 5 3 Occupants X 155 Btuh/occ. = 828 Infiltration: 4,771 X 1.27 X 73.46 X 0.00523 = 2,322 Air Sensible CFM ELA OW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 828 Ener Pro 6.7 by Ener Soft User Number. 6712 RunCode: 2016-04-07711:47:24 ID: Page 45 of 49 .f RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Madison Club 236 4/7/2016 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Living Area Outdoor Dry Bulb Temperature 112 OF Floor Area 1,413.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Ranqe: 34 OF Opaque Surfaces R-38 Roof Attic R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) *R-13 Wall Orientation (M (NE) (SE) (SW) (NM Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,413.0 0.0260 56.0 704.0 0.0690 29.0 548.4 0.0690 31.0 707.4 0.0690 31.0 489.4 0.0690 30.2 745.0 0.1020 0.0 221 40.0 0.0 491 18.0 0.0 221 18.0 0.0 221 Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 21 R2 R1 19 Q1 P3 N4 P2 P1 Orientation (NE) (NE) (NE) (NE) (SE) (SE) (SE) (S W) (SIM Btu/hr 1,409 1,173 1,513 1,021 1 7,1731 Shaded Area X X X X X X X X GLF 15.3 + 12.3 + 12.3 + 15.3 + 12.3+ 12.3 + 12.3 + 12.3 + 12.3 + Unshaded Area X X X X X X X X GLF 23.0 = 18.1 = 18.1 = 23.0 = 16.4= 16.4 = 16.4 = 16.4 = 16.4 = Page Total Btu/hr 0.01 90.0 2,072 0.0 16.0 289 0.0 16.0 289 0.0 81.0 1,865 12.6X 0.0X 155 18.0 0.0 221 40.0 0.0 491 18.0 0.0 221 18.0 0.0 221 5,824 Internal Gain Btu/hr Occupants 4 2 Occupants X 245 Btuh/occ. = 1,039 Equipment 1,413 Floor Area X 0.50 w/sgft = 2,411 Infiltration: 1.064 X 1.27 X 58.28 X 42 = 3,297 Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 24,4761 Latent Gain Btu/hr Occupants 4 2 Occupants X 155 Btuh/occ. = 657 Infiltration: 4,771 X 1.27 X 58.28 X 0.00523 = 1,842 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 6571 r -J RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Madison Club 238 4/7/2016 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Living Area Outdoor Dry Bulb Temperature 112 OF Floor Area 1,413.0 ft-- Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 T Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr N3 (SM 62.0 X 12.3 + 0.0 X 16.4 = 761 N2 (SIAL 62.0 X 12.3 + 0.0 X 16.4 = 761 S2 (SKq 39.6 X 12.3 + 0.0 X 16.4 = 486 N1 (NK9 0.0 X 12.3 + 40.0 X 18.1 = 723 18 (NKK 0.0 X 15.3 + 77.0 X 23.0 = 1,773 51 (NM 0.0 X 12.3 + 12.6 X 18.1 = 228 X + X = X+ X = X + X = Page Total 4, 732 Internal Gain Btu/hr Occupants 4 2 Occupants X 245 Btuh/occ. = 1,039 Equipment 1,413 Floor Area X 0.50 w/sgft = 2,411 Infiltration: 1.064 X 1.27 X 58.28 X 42 = 3,297 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 24,476 Latent Gain Btu/hr Occupants 4 2 Occupants X 155 Btuh/occ. = 657 Infiltration: 4,771 X 1.27 X 58.28 X 0.00523 = 11842 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 657 Ener Pro 6.7 by Ener Soft User Number: 6712 RunCode: 2016-04-07711:47:24 ID: Page 47 of 49 _ti RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Madison Club 23B 4/7/2016 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Master Bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 1,570.0 ft-- Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF 1 Outdoor Dailv Ranae: 34 OF Opaque Surfaces R-38 Roof Attic R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) R-21 Wall (W.21.2x6.16) 'R-13 Wall Orientation Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 1,570.0 0.0260 56.0 654.0 0.0690 29.0 323.0 0.0690 31.0 605.1 0.0690 31.0 332.2 0.0690 30.2 456.0 0.1020 0.0 14.7 12.3 0.0 16.4 18.0 12.3 0.0 16.4 96.8 15.3 0.4 Page Total Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 12 22 M1 V1 W2 W1 23 U2 U1 Orientation (NE) (NE) (SE) (SE) (SW) (S W) (S W) (S W) (SIM Shaded Unshaded Area X X X X X X X X GLF + + + + + + + + Area X X X X X X X X GLF = = = = = = = 0.0 12.3 36.0 18.1 0.0x 15.3+ 90.0x 23.0= 14.4 12.3 0.0 16.4 0.0 12.3 12.6 16.4 14.7 12.3 0.0 16.4 18.0 12.3 0.0 16.4 96.8 15.3 0.4 20.8 26.1 12.3 0.0 16.4 18.9 12.3 0.0 Page Total Btu/hr 2,286 1,309 691 1,2941 6,2731 Btu/hr 650 2,072 177 207 181 221 1,490 320 Internal Gain Btu/hr Occupants 4 7 Occupants X 245 Btuh/occ. = 1,1 Equipment 1,570 Floor Area X 0.50 w/sgft = 2,6 Infiltration: 1.064 X 1.27 X 64.76 X 42 = Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 19,6411 Latent Gain Btu/hr Occupants 4 7 Occupants X 155 Btuh/occ. _ Infiltration: 4,771 X 1.27 X 64.76 X 0.00523 = C Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 7301 I EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2016-04-07711:47:24 ID: Pape 48 of 49 1 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Madison Club 23B 4/7/2016 ROOM INFORMATION DESIGN CONDITIONS Room Name 2nd Floor Master Bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 1, 570.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr TI (NVt9 0.0 X 12.3 + 17.8 X 18.1 c 322 X + X = X + X = X + X = X + X = X + X = X + X = X + X = X. + X = Page Total 322 Internal Gain Btu/hr Occupants 4 7 Occupants X 245 Btuh/occ. = 1,154 Equipment 1,570 Floor Area X 0.50 w/sgft = 2,679 Infiltration: 1.064 X 1.27 X 64.76 X 42 = 3,663 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 19,641 Latent Gain Btu/hr Occupants 4 7 Occupants X 155 Btuh/occ. = 730 Infiltration: 4,771 X 1.27 X 64.76 X 0.00523 = 2,047 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 730 Ener Pro 6.7 by EnerjqySoft User Number: 6712 RunCode: 2016-04-07711:47:24 ID: Page 49 of 49