Loading...
BMCH2019-044178-495 CALLE TAMPICO DuW1A2(/ VOICE (760) 777-7125 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 11/4/2019 Permit Type/Subtype: MECHANICAL/ Owner: Application Number: BMCH2O19-0441 MARCIA L. LUND TRUST Property Address: 80135 MERION 80135 MERION APN: 762191006 LA QUINTA, CA 92253 Application Description: LUND / (25 DUCT RUNS - (20) SUPPLIES AND (5) RETURNS Property Zoning: Application Valuation: $7,000.00 Applicant: Contractor: Contractor: IE INC D HARRISON ENTERPRISES INC DBA GENERAL AIR 31225 LA BAYA 31170 RESERVE DRIVE WESTLAKE VILLAGE, CA 91362 NOV 0 4 2019 THOUSAND PALMS, CA 92276 CITY OF LA QUINTA (760)343-7488 DESIGN&DEVELOPMENT DEPARTMENT Llc. No.:686310 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C20. C36 License No.: 686310 Date: �ITi 1 �t , Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's N Lender's Addres WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of th� v�ork for which this permit is issued. --� I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: CyCRESS INSURANCE COMPANY Policy Number: HAWC012965 — I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. I Date:!�I `-)I Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above - mentioned property for inspection purposes. Date: it kh Signature (Applicant or Agent): ,r­—�- "'_— Date: 11/4/2019 Application Number: BMCH2O19-0441 Property Address: 80135 MERION APN: 762191006 Application Description. LUND / (25 DUCT RUNS - (20) SUPPLIES AND (5) RETURNS Property Zoning: Application Valuation: $7,000.00 Applicant: IE INC 31225 LA BAYA WESTLAKE VILLAGE, CA 91362 Owner: MARCIA L. LUND TRUST 80135 MERION LA QUINTA, CA 92253 Contractor: HARRISON ENTERPRISES INC DBA GENERAL AIR 31170 RESERVE DRIVE THOUSAND PALMS, CA 92276 (760)343-7488 LIc. No.: 686310 Detail: REPLACE (25) DUCT RUNS (20) SUPPLIES AND (5) RETURNS. A-8 INSULATION PER 2016 CALIFORNIA BUILDING CODES. DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - OTHER EQUIPMENT 101-0000-42402 0 $40.25 DESCRIPTION ACCOUNT QTY AMOUNT HVAC CHANGEOUT - OTHER EQUIPMENT PC 101-0000-42600 0 $40.25 Total Paid for MECHANICAL CHANGEOUT 2019: $80.50 DESCRIPTION ACCOUNT CITY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $101.97 Total Paid for PERMIT ISSUANCE: $101.97 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 GF—%1 fthe € ESEFCY --- PERMIT # �" '�• — Q -1 Y' PLAN LOCATION: Project Address: 80135 Merion Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: Replace 25 duct runs - 20 supplies, 5 returns Applicant Name: Steven Schnierer Address: 31225 La Baya Drive Suite 213 City, ST, Zip: Westlake Village, CA 91362 Telephone: 818-735-7876 Email: swschnierer@outlook.com Valuation of Project S 7,000.00 Contractor Name: General Air Conditioning New SFD Construction: Address: 31170 Reserve Drive Conditioned Space SF City, St, Zip Thousand Palms, CA 92276 Garage SF Telephone: 760-343-7488 Patio/Porch SF Email: Fire Sprinklers SF State Lic: 686310 City Bus Lic: Arch/Eng Name: Construction Type: Occupancy: Address: Grading: City, St, Zip Telephone: Bedrooms: Stories: # Units: Email: State Lic: City Bus Lic: Property Owner's Name: Richard Lund New Commercial / Tenant Improvements: Address: 80135 Merion Total Building SF City, ST, Zip La Quinta, CA 92253 Construction Type: Occupancy: Telephone: Email: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 OFFICE USE ONLY # Submittal Req'd Rec'd Plan Sets -Structural-Calcs- Truss Calcs Title 24 Calcs Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License Dabs r City of La Qtinta DeParneent of Building and Safety 78495 Calls Tampico La QU[n'tk CA 92353 Re: GenwW Air Comlltianing and Plumbing Dear Permits Office: I hereby authorize for mineral Air Condi#o n MW and obtain a VAC mechanical It and/ora�LUMBING big pD file for P party located at; for my Hamm of Propely odor; �/ �� [ l / Gelllml Air CondWoNng MM pW td:ir� Su7o Re"M fl� Thousand PAW CA 97B CERTIFICATE OF COMPLIANCE Alterations to Space Conditioning Systems (formerly CF-IR-ALT HVAC) Project Name: Richard Lund I Date Prepared: CF1R-ALT-02-E (Page 1 of 3) 2019-11-04 A. General Information CF111-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CFIR-ALT-02 document for each dwelling unit. 01 Project Name Richard Lund 02 Date Prepared 2019-11-04 03 Project Location 80135 Merion 04 Building Type Single family 05 CA City La Quinta 06 Dwelling Unit Name Richard Lund 07 Zip Code 92253 08 Dwelling Unit Conditioned 3880 Floor Area (ftz) Number of Space 09 Climate Zone 15 10 Conditioning (SC) Systems in 1 this Dwelling Unit: B. Space Conditioning (SC) System Information 01 02 03 04 05 06 07 08 09 10 Is the SC Installing a SC System SC System CFA served system a refrigerant Installing new SC Installing Installing Installing Identification or Location or Area by this SC ducted containing system more than 40 entirely new entirely new Name Served System (ftz) system? component? components? feet of ducts? duct system? SC system? Alteration Type System 1 Location 1 3880 Yes No No Yes No No Extension of existing duct system C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)1Diib) 01 02 System Identification or Name New Duct R-Value System 1 R-8 Registration Number: 419-A020121009A-000-000-0000000-0000 Registration Date/Time: 2019-11-04 07:44:12 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-11-04 07:44:19 Schema Version: rev 20180426 CERTIFICATE OF COMPLIANCE CF111-ALT-02-E Alterations to Space Conditioning Systems (formerly CF-IR-ALT HVAC) (Page 2 of 3) Required Documentation: CF2R-MCH-01-E - Space Conditioning Systems - Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10,12 and 13) and R8 (CZ 11 and 14-16) CF211 and CF311-MCH-20-1­1 Duct Leakage Test - Leakage rate compliance: <=15%, or <=10% leakage to outside, or seal all accessible leaks Exceptions: Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH-20 duct leakage testing requirements D. Altered Space Conditioning System (Sections 150.2(b)1E and F) This section does not apply to this project. E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)iDiia and 150.2(b)1E, F) This section does not apply 'o this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C) This section does not apply to this project. Registration Number: 419-A020121009A-000-000-0000000-0000 Registration Date/Time: 2019-11-04 07:44:12 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-11-04 07:44:19 Schema Version: rev 20180426 CERTIFICATE OF COMPLIANCE MR-ALT-024 Alterations to Space Conditioning Systems (formerly CF-IR-ALT HVAC) (Page 3 of 3) Documentation Author's Declaration Statement 1.1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Cassidy Snow C S no-w Company: Signature Date: I Permit E Raters 2019-11-04 Address: CEA/ HERS Certification Identification (if applicable): 31225 La Baya Drive City/State/Zip: phone: Westlake Village CA 91362 918-735-7876 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for Clip building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for.approval.with this building perrait application. 5. 1 will ensure that a registered copy of this Certificate of Compliance shall be made 0vailabTewith t4e building permit(s) Issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is required to be Included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Responsible Designer Signature: Patrick Somers PatKck Some r Company: Date Signed: General Air Conditioning 2019-11-04 Address: License: 31170 Reserve Drive 686310 City/State/Zip: Phone: Thousand Palms CA 92276 760-343-7488 Digitally signed by CHEERS". This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 419-A020121009A-"-000-0000000-0000 Registration Date/Time: 2019-11-04 07:44:12 HERS Provider: CHEERS CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2019-11-04 07: 4:19 Schema Version: rev 20180426