BRES2019-016078-495 CALLE TAMPICO D� VOICE (760) 777-7125 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 11/6/2019 Permit Type/Subtype: BUILDING RESIDENTIAL/DWELLING - SINGLE FAMILY DETACHED Owner: Application Number: BRES2019-0160 JOE W. STEMMER JR. Property Address: 54575 AVENIDA VELASCO 54575 AVENIDA VELASCO APN: 774283014 LA QUINTA, CA 92253 Application Description: STEMMER / 1,878SF DWELLING/VB/RES-3/CLASS A-FR/13D Property Zoning: Application Valuation: $122,526.70 Applicant: LJ u Contractor: JOE W STEMMER JRD JOE W STEMMER JR 42215 WASHINGTON ST#355 42215 WASH INGTON ST#355 PALM DESERT, CA 92211 NOV 0 6 2019 PALM DESERT, CA 92211 CITY OF LA QUINTA (760)880-3525 DESIGN & DEVELOPMENT DEPARTMENT Llc. No.: 605857 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of tqe Business a ofessions Code, and my License is in full force and effect. License Class: 1 License No.: 605857 Date: h , I 1 Contractor: OWNER-BUIIA.W-R DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. workers' compensation insurance carrier and policy number are: Car ri E?fEfyiPT Policy Number: I certify that in the performance of the work for which this permit is issued, I shall of employ any person in any manner w as to become subject to the workers' compensation laws of California, and agree that, if I should a subject to the workers' compensation provisions of$ecti 37 0 ofthe b ode, I shall forthwith comply with those rovisions. Date: Applican WARNING: FAILURE TO SECURE WOR E 'COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above inf mation is correct. I agree to comply with all city and county ordinances and state laws lating to building construction, and hereby authorize representatives of this cfl to r upon the above - mentioned ro rty for inspection purposes, Date: fl J Signature (Applicant orAgentl• Date: 11/6/2019 Application Number: BRES2019-0160 Property Address: 54575 AVENIDA VELASCO APN: 774283014 Application Description: STEMMER / 1,878SF DWELLING/VB/RES-3/CLASS A-FR/13D Property Zoning: Application Valuation: $122,526.70 Applicant: JOE W STEMMER JR 42215 WASHINGTON ST #355 PALM DESERT, CA 92211 Owner: JOE W. STEMMER JR. 54575 AVENIDA VELASCO LA QUINTA, CA 92253 Contractor: JOE W STEMMER JR 42215 WASH INGTON ST#355 PALM DESERT, CA 92211 (760)880-3525 LIc No.: 605857 Detail: STEMMER / 1,878 SF DWELLING [VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 2016 CALIFORNIA BUILDING CODES. FINANCIAL INFORMATION DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $5.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $5.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - CIVIC CENTER 252-0000-43200 0 $942.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - LIBRARIES 253-0000-43200 0 $344.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - PARKS/REC 251-0000-43200 0 $2,048.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 DESCRIPTION ACCOUNT CITY AMOUNT DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 DESCRIPTION ACCOUNT CITY AMOUNT TEMP POWER SERVICE 101-0000-42403 0 $26.68 DESCRIPTION ACCOUNT CITY AMOUNT TEMP POWER SERVICE PC 101-0000-42600 0 $18.68 Total Paid for ELECTRICAL: $45.36 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0 $27.22 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF, PC 101-0000-42600 0 $11.20 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $160.10 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $52.83 Total Paid for ELECTRICAL - NEW CONSTRUCTION: $251.35 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT <=7KSF 101-0000-42408 0 $40.02 DESCRIPTION ACCOUNT CITY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT <=7KSF PC 101-0000-42600 0 $40.02 Total Paid for GRADING: $80.04 DESCRIPTION ACCOUNT I CITY AMOUNT CONDENSER/COMPRESSOR 101-0000-42402 0 $40.02 DESCRIPTION ACCOUNT CITY AMOUNT CONDENSER/COMPRESSOR PC 101-0000-42600 0 $26.68 DESCRIPTION ACCOUNT CITY AMOUNT EXHAUST HOOD 101-0000-42402 0 $13.34 DESCRIPTION ACCOUNT CITY AMOUNT EXHAUST HOOD PC 101-0000-42600 0 $5.34 DESCRIPTION ACCOUNT CITY AMOUNT FURNACE 101-0000-42402 0 $40.02 DESCRIPTION ACCOUNT CITY AMOUNT FURNACE PC 101-0000-42600 0 $26.68 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN 101-0000-42402 0 $53.36 DESCRIPTION ACCOUNT CITY AMOUNT VENT FAN PC 101-0000-42600 0 $21.36 Total Paid for MECHANICAL: $226.80 DESCRIPTION ACCOUNT CITY AMOUNT MULTI -SPECIES RESIDENTIAL 8.1-14 UNITS - 2019 UPDATE 101-0000-20310 0 $554.00 Total Paid for MULTI -SPECIES RESIDENTIAL: $554.00 DESCRIPTION ACCOUNT QTY AMOUNT NEW CONSTRUCTION PERMIT 101-0000-42400 0 $572.68 Total Paid for NEW CONSTRUCTION PERMIT: $572.68 DESCRIPTION ACCOUNT CITY AMOUNT NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $1,131.57 Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,131.57 DESCRIPTION ACCOUNT CITY AMOUNT PLAN CHECK DEPOSIT- RESIDENTIAL 101-0000-42600 1 $750.00 Total Paid for PLAN CHECK DEPOSIT - RESIDENTIAL: $750.00 DESCRIPTION ACCOUNT CITY AMOUNT BACKFLOW DEVICE 101-0000-42401 0 $13.34 DESCRIPTION ACCOUNT CITY AMOUNT BACKFLOW DEVICE PC 101-0000-42600 0 $5.34 DESCRIPTION ACCOUNT CITY AMOUNT BUILDING SEWER 101-0000-42401 0 $26.68 DESCRIPTION ACCOUNT CITY AMOUNT BUILDING SEWER PC 101-0000-42600 0 $18.68 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $146.74 DESCRIPTION ACCOUNT CITY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $146.74 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 1-4 OUTLETS 101-0000-42401 0 $13.34 DESCRIPTION ACCOUNT CITY AMOUNT GAS SYSTEM, 1-4 OUTLETS PC 101-0000-42600 0 $26.68 DESCRIPTION ACCOUNT CITY AMOUNT ROOF DRAIN 101-0000-42401 0 $13.34 DESCRIPTION ACCOUNT QTY AMOUNT ROOF DRAIN PC 101-0000-42600 0 $13.34 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT 101-0000-42401 0 $13.34 DESCRIPTION ACCOUNT CITY AMOUNT WATER HEATER/VENT PC 101-0000-42600 0 $8.00 DESCRIPTION ACCOUNT CITY AMOUNT WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $13.34 DESCRIPTION ACCOUNT CITY AMOUNT WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $13.34 Total Paid for PLUMBING FEES: $472.24 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 $21.00 Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 DESCRIPTION ACCOUNT CITY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $15.93 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $15.93 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 DESCRIPTION ACCOUNT CITY AMOUNT 101-0000-42600 ($750.00) DESCRIPTION ACCOUNT CITY AMOUNT SINGLE FAMILY DETACHED 2018 UPDATE 224-0000-20320 0 $750.00 DESCRIPTION ACCOUNT CITY AMOUNT SINGLE FAMILY DETACHED 2018 UPDATE 224-0000-20320 0 $1,560.00 Total Paid for TUMF - RESIDENTIAL: $1,560.00 PERMIT# ZO(� — df'(o0 PLAN LOCATION - Project Address: 54575 Ave Velasco Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: 774-283-014 new SFR 1878 Sq Ft. ::ant Name: Joe W. Stemmer 42215 Washington St, #355 City, ST, Zip: Palm Desert, CA 92211 Telephone: 760-880-3525 Email: Stemmer@dc.rr.com Valuation of Project $ 200,000 ;..tor Name: Joe W. Stemmer Jr New SFD Construction: Address:42215 Washington St, #355 Conditioned Space 1878 SF City, St. Zip Palm Desert, CA 92211 Garage 450 SF 1'elephone:760-880-3525 Patio/Porch 150 SF Email:jstemmer@de.rr.eom Fire Sprinklers 1878 SF State Lic: 605857 City Bus Lic:763387 f ;rch/Eng Name: GLS Design i.. Construction Type: new conventional Occupancy: SFR Address:74991 Joni Dr. Ste 9 Grading: City, St, Zip Palm Desert. CA 92211 Telephone: 760-880-3525 Bedrooms: 3 Stories:l 7# Units: Email: jstemmer@dc.rr.com [StaLeLic: 605857 00, Bus Lic:763387 Property Owner's Name: Contractor New Commercial / Tenant Improvements: .Address: Total Building SF City. ST. Zip Construction Type: Occupancy: Telephone: Email: 78495 CALLE TAMPICO LA QUINTA, CA 92253 760-777-7000 CERTIFICATE OF COMPLIANCE Desert Sands Unified School District x��o 47950 Dune Palms Road Q uinta, CA 92253 Date: 11/6/2019 La �' =:•�r• No.: 19-01524-1 (760)771-8515 ° !'.'' ' Owner: Joe Stemmer Email: Address: 54575 Avenida Velasco Jurisdiction: La Quinta City: La Quinita Tract #: Type: Single Family Residential Lot # Street No. Street Name Sq. Feet APN Permit No. 54575 Avenida Velasco 1878 774-283-014 Comments: RECEIVED NOV 0 6 2019 CITY OF LA QUINTA DESIGN AND DEVELOPMENT DEPARTMENT At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement mobile homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fess imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $3.79 X 1878 S.F. or $7,117.62 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued. Fees Paid By: CCJBl3VA ljoe Stemmer Check No.: 505052204 Bank Name/Recipient of Certificate Telephone: Funding: Residential By Scott L. Bailey Superintendent Fee Collected/ Exempted by: Rodney Slagle Certificate Fees Due: $7,117.62 Original Payment(s) Rec'd: $0.00 New Payment Rec'd: $7,117.62 Over/Under: $0.00 NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you mad, pros:ese Vie fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District(`s) behalf, whichever is earlier.' Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL. 'ORDING REQUESTED BY v�°yers Title - IE 1kECORDED MAIL THIS DOCUMENT AND TAX STATEMENTS TO: Joe W. Stemmer Jr., President 42215 Washington Street, #355 Palm Desert, California 92211 DOC # 2019-0120411 04/10/2019 11:15 AM Fees: $17.00 Page 1 of 2 Recorded in Official Records County of Riverside Peter Aldana Assessor -County Clerk -Recorder '"This document was electronically submitted to the County of Riverside for recording" Receipted by: LISA #580 APN: 774-283-014-4 Escrow No: PDL16900-LT139-NB 1 Title No: 619640579 GRANT DEED Space above this line for Recorder's use T$AE UNDERSIGNED GRANTORS) DECLARE(S) DOCUMENTARY TRANSFER TAX IS $82.SO El computed on full value of property conveyed ® City of La Quir;ta, ^ W FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Jean Burns, SurVM �.J 'I"Sif�Op� -1,Q,-1JUy-nS �Q�,j'y�,�� �W5� LYSA ikrinutto,5-7 hereby GRANT(S) to I" W. Stemmer Jr., Construction, Inc. ;lowing described real property in the County of Riverside, State of CALIFORNIA: For legal description of the real property herein, see Exhibit A attached hereto and made a part hereof. Commonly known as: APN: 774-283-014-4 , La Quinta, CA 92253 Dated: April 2 2019 The Burns Family Trust UTA March 6, 1987 . ea n Bu ms, 5�)rvwi (1Twskr' A notary public or other officer completing this certificate verifies only the identity of the individual who signed the mert to which this certificate is attached, and not the truthfulness, accuracy, or validity of that document. OF CALIFORNIA ) ) SS. '-UJNTY OF On dt 4 it ZO/ m before me, _., Notary Public, personally appeared !.r proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to w;thin instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized :::apacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of 'rich the person(s) acted, executed the instrument. y under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true correct. WITNESS my hand and official seal. 4 CHRISi{H119SEN a COMM. #2174926 i c Notary Puh1It • Callfomia Signature " Icy Comm l]le Cou sr' 1 �: Maii tax statements to: Return address as shown above Building Permit Number: { KW2_619 — (o0 Project Description: i SFR Exempt: 0 (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan Plan Submittal Date 7/30/2019 Job Site Address! 54575 Avenida Velasco Owner's Name Number, Street, or PO City, State, Postal C Owner's Phone Nur Owner's E-Mail Add Joe W. Stemmer Jr. 42215 Washington St #355 Palm Desert, CA. 92211 760-880-3525 i ste nn m erCo? d c,r rc o m Project Manager's Namel Joe Stemmer Jr. Project Managers Phone Number 760-880-3525 Project Manager's E-mail Address jstemmerndc.mcom Builder 1 Contractor; Joe Stemmer Jr. Number, Street or PO Box' 42215 Washington St. #355 City, State, Postal Code' Palm Desert, CA. 92211 Project Square Footage I Approx. 1,835 sq ft F j � +City Approval By Renado Gouktlock-DEC/Burrtec Wast Date of City Approval Al k. n l,Q _ Materials To Be Discarded: Product Trash Asphalt Brick/Block Cardboard ' Commingled Concrete _ Drywall Donated / Reuse' Tons 7.00 Not recyclable 0.00 Recyclable 0.00 Recyclable 0.00 Recyclable 0.00 Recyclable 8.00 Recyclable 0.75 Recyclable 0,00 Recyclable Product Masonry (broken) Plaster Scrap Metal Tile (floor) Tile (roof) Wood Landscape Debris w o N to o V O LU Z a Tons 0,05 I Recyclable 0.20 1 Recyclable tr)<rIr] "Describe Items Ij Totals: Recycle Trash Projected Diversion: I understand it is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste Is diverted from landfiliing. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for lhe,owner. However, the DMP Is still issued in the name of the property owners) and the owner retains legal responsibility for ensuring that the provisions of the DMP re a hared t . T property owners} and general contractor shall be kept informed of the diversion progress through bi-mon hly parts. E IF- auling, ail refuse material from this project site must be taken to an approved recycler or transfer Superintendant Clate I BUILDING ENERGY ANALYSIS REPORT PROJECT: STEMMER RESIDENCE 54575 AVENIDA VELASCO LA QUINTA, CA 92253 Project Designer: GLS ARCHITECTURE GROUP INC. 74991 JONI DR #9 PALM DESERT, CA 92260 760 340.3528 Report Prepared by: Armando Chavez 44890 SEELEY LA QUINTA, CA 92253 0160 _ 760 278.1840 -•CITY OF I._A, BUILDING DIVISION R:,.. IE ED FOR , CODE C[- MPLIANCE i DATF P-Y. Job Number: c7f Fl OF— 18-GLS/051 - 039 Date: 7/8/2019 [?ECEI\/PDE JUL 09 2019 My OF L4 QUINTA SIGN A . 0 OFVE�OPMEf T DEPARTMEar The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF-1 R-PRF-01-E Certificate of Compliance 3 Form RMS-1 Residential Measures Summary 12 Form MF-1 R Mandatory Measures Summary 13 HVAC System Heating and Cooling Loads Summary 17 ! EnergyPro 7.1 by EnergySoft Job Number: ID: 18-GLS/051 - 039 User Number: 20648 1 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: STEMMER RESIDENCE Calculation Date/Time: 11:05, Mon, Jul 08, 2019 Calculation Description: Title 24 Analysis Input File Name: 039 - 54575 AVENIDA VELASCO.ribd16x CF1R-PRF-01 Page 1 of 9 GENERAL INFORMATION 01 Project Name STEMMER RESIDENCE 02 Calculation Description Title 24 Analysis 03 Project Location 54575 AVENIDA VELASCO 04 City LA QUINTA 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 09 Software Version CBECC-Res 2016.3.1 (1019) 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 90 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ftZ) 1878 15 Number of Zones 1 16 Slab Area (ftZ) 1878 17 Number of Stories 1 18 ! Addition Cond. Floor Area(ft2) n/a 19 Natural Gas Available Yes 20 Addition Slab Area (ftZ) n/a 21 Glazing Percentage (%) 14.8% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ftZ-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 0.27 3.23 -2.96 -1096.3% Space Cooling 82.62 68.78 13.84 16.8% IAQ Ventilation 1.19 1.19 0.00 0.0% Water Heating 6.75 12.31 -5.56 -82.4% Photovoltaic Offset ----- 0.00 0.00 ---- Compliance Energy Total 90.83 85.51 5.32 5.9% Registration Number: 219_P010108331 B-000-000-0000000-000o Registration Date/Time: 2019-07-08 11:10:15 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-07-08 11:06:31 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: STEMMER RESIDENCE Calculation Date/Time: 11:05, Mon, Jul 08, 2019 Calculation Description: Title 24 Analysis Input File Name: 039 - 54575 AVENIDA VELASC0.ribd16x CF1 R-PRF-01 Page 2 of 9 ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR 54.3 52.1 0.0 52.1 ❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. ❑ Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified. Notes: • PV generation will be capped @ proposed design electric use no batte REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis • Cool roof • Insulation below roof deck • Window overhangs and/or fins Exposed slab floor in conditioned zone I HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis Additional detail is provided in the building components tables below Building -level Verifications: • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: • -- None -- Registration Number: 219-P010108331B-000-000-0000000-0000 Registration Date/Time: 2019-07-08 11:10:15 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-07-08 11:06:31 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: STEMMER RESIDENCE Calculation Date/Time: 11:05, Mon, Jul 08, 2019 Calculation Description: Title 24 Analysis Input File Name: 039 - 54575 AVENIDA VELASCO.ribd16x CF1R-PRF-01 Page 3 of 9 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems STEMMER RESIDENCE 1878 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 (N) 1878 Conditioned HVAC1 1878 8 DHW Sys 1 n/a OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) 518 - N (N) 1878 R-15 + R4 0 Right 518 46 90 400 - E (N) 1878 R-15 + R4 90 Front 400 152.58 90 518 - S (N) 1878 R-15 + R4 180 Left 518 48 90 400 - W (N) 1878 R-15 + R4 270 Back 400 53 90 1878 (N) 1878 R-38 + R-11 n/a n/a 1878 n/a n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic (N) 1878 Attic Roof(N) 1878 Ventilated 0.2 0.86 0.88 No Yes Registration Number: 219-P010108331B-000-000-0000000-0000 Registration Date/Time: 2019-07-0811:10:15 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-07-08 11:06:31 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: STEMMER RESIDENCE Calculation Date/Time: 11:05, Mon, Jul 08, 2019 Calculation Description: Title 24 Analysis Input File Name: 039 - 54575 AVENIDA VELASCO.ribdl6x CF1 R-PRF-01 Page 4 of 9 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ftZ) U-factor SHGC Exterior Shading 4050-6 Window 518 - N (Right-0) 40 5.0 1 20.0 0A4 0.25 Insect Screen (default) 4016-7 Window 518 - N (Right-0) 4.0 1.5 1 6.0 0.44 0.25 Insect Screen (default) 4050-8 Window 518 - N (Right-0) 4.0 5-0 1 20.0 0.44 0.25 Insect Screen (default) 3076-9 Window 400 - E (Front-90) 3.0 7.5 1 22.5 0.37 0.25 Insect Screen (default) 12676-10 Window 400 - E (Front-90) 125 7.5 1 93.8 0.48 0.25 Insect Screen (default) 3010-11 Window 400 - E (Front-90) 3.0 1 0 1 3.0 0.37 0.25 Insect Screen (default) 6010-12 Window 400 - E (Front-90) 10.0 6.0 0.1 6.0 0.37 0.25 Insect Screen (default) 6010-13 Window 400 - E (Front-90) 10.0 6.0 0.1 6.0 0.37 0.25 Insect Screen (default) 4010-1 Window 518 - S (Left-180) 4.0 1.0 1 4.0 0.37 0.25 Insect Screen (default) 4010-2 Window 518 - S (Left-180) 4.0 1.0 1 4.0 0.37 0.25 Insect Screen (default) 5080-3 Window 518 - S (Left-180) 5.0 8.0 1 40.0 0.48 0.25 Insect Screen (default) 5010-4 Window 400 - W (Back-270) 5.0 1.0 1 5.0 0.44 0.25 Insect Screen (default) 6080-5 Window 400 - W (Back-270) 6.0 8.0 1 48.0 0.48 0.25 Insect Screen (default) OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ftZ) U-factor 2880 400 - E 21.3 0.50 Registration Number: 219-P010108331B-000-000-0000000-0000 Registration Date/Time: 2019-07-08 11:10:15 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-07-08 11:06:31 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: STEMMER RESIDENCE Calculation Date/Time: 11:05, Mon, Jul 08, 2019 Calculation Description: Title 24 Analysis Input File Name: 039 - 54575 AVENIDA VELASCO.ribdl6x CF1 R-PRF-01 Page 5 of 9 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 4050-6 1.5 0.1 4 4 0 0 0 0 0 0 0 0 0 4016-7 1.5 0.1 4 4 0 0 0 0 0 0 0 0 0 4050-8 1.5 0.1 4 4 0 0 0 0 0 0 0 0 0 3076-9 10 0.1 10 10 0 0 0 0 0 0 0 0 0 12676-10 10 0.1 10 10 0 0 0 0 0 1 0 0 0 0 3010-11 10 0.1 10 10 0 0 0 0 0 0 0 0 0 6010-12 10 0.1 10 10 0 0 0 0 0 0 0 0 0 6010-13 10 0.1 10 10 0 0 0 0 0 0 0 0 0 4010-1 1.5 0.1 4 4 0 0 0 0 0 0 0 0 0 4010-2 1.5 0.1 4 4 0 0 0 0 0 0 0 0 0 5080-3 1.5 0.1 4 4 0 0 0 0 0 0 0 0 0 5010-4 1.5 0.1 4 4 0 0 0 0 0 0 0 0 0 6080-5 15 0.1 4 4 0 0 0 0 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Construction Name Surface Type Construction Type Framing Total Cavity R-value Winter Design U-factor Assembly Layers Attic Roof(N) 1878 Attic Roofs Wood Framed Ceiling 2x4 Top Chord of Roof Truss @ 24 in. O.C. R 11 0.088 • Cavity/Frame: R-11 /2x4 Top Chrd Roof Deck: Wood Siding/sheathing/decking Roofing: Light Roof (Asphalt Shingle) R-38 + R-11 Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 • Inside Finish: Gypsum Board Cavity/Frame: R-9.1 /2x4 Over Ceiling Joists: R-28.9 insul. R-15 + R4 Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 15 0.064 • Inside Finish: Gypsum Board • Cavity / Frame: R-15 / 2x4 • Sheathing/Insulation: R4 Sheathing Exterior Finish: 3 Coat Stucco Registration Number: 219-P010108331B-000-000-0000000-0000 Registration Date/Time: 2019-07-08 11:10:15 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-07-08 11:06:31 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: STEMMER RESIDENCE Calculation Date/Time: 11:05, Mon, Jul 08, 2019 Calculation Description: Title 24 Analysis Input File Name: 039 - 54575 AVENIDA VELASCO.ribd 1 6x CF1 R-PRF-01 Page 6 of 9 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated 18782 (N) 1878 1878 0.1 None 0 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Standard DHW Heater 1 (1) 1 .0% WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Uniform Energy Factor / Energy Factor / Efficiency Input Rating / Pilot / Thermal Efficiency Tank Insulation R-value (Int/Ext) Standby Loss / Recovery Eff First Hour Rating / Flow Rate NEEA Heat Pump Brand / Model / Other Tank Location or Ambient Condition DHW Heater 1 Gas Small Storage 1 50 0.575 EF <= 75 kBtu/hr R-0/R-0 0 n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC1 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Efficiency Heating Component 1 CntrlFurnace 1 80 AFUE Registration Number: 219-P010108331B-000-000-0000000-0000 Registration Date/Time: 2019-07-08 11:10:15 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-07-08 11:06:31 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: STEMMER RESIDENCE Calculation Date/Time: 11:05, Mon, Jul 08, 2019 Calculation Description: Title 24 Analysis Input File Name: 039 - 54575 AVENIDA VELASCO.ribd16x CF1R-PRF-01 Page 7 of 9 HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Name System Type Number of Units Efficiency EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 I SplitAirCond I 1 I 11 I T1-hers-cool 14 Not Zonal Single Speed Cooling Component HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Not Required Not Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Sealed and tested 8 Attic None Air Distribution System 1-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required 50 Not Required Not Required Not Required Not Required n/a HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 Registration Number: 219-P010108331B-000-000-0000000-0000 Registration Date/Time: 2019-07-08 11:10:15 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-07-08 11:06:31 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: STEMMER RESIDENCE Calculation Date/Time: 11:05, Mon, Jul 08, 2019 Calculation Description: Title 24 Analysis Input File Name: 039 - 54575 AVENIDA VELASCO.ribd16x CF1 R-PRF-01 Page 8 of 9 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ IAQ Recovery HERS Verification SFam IAQVentRpt I 49 0.25 Default 0 Required PROJECT NOTES -- ALL EXISTING AND PROPOSED INPUT DATA USED IN THIS REPORT WAS PROVIDED BY THE PLANS PREPARER. -- LOAD CALCULATIONS AND AC SIZING EQUIPMENT SHALL BE VERIFIED BY THE AC CONTRACTIOR PRIOR TO PLACEMENT OF ITS ORDER. LOADS DOCUMENTED IN THIS REPORT ARE SUGGUESTED LOADS ONLY. -- AC EQUIPMENT'S EFFICENCY SHALL BE EQUAL (OR BETTER) THAN REQUIRED BY THIS REPORT. -- ANY ALTERATION OR DEVIATION FROM THIS REPORT WILL BE GENERAL CONTRACTOR'S RESPONSABILITY. Registration Number: 219-Po1o108331B-000-000-0000000-0000 Registration Date/Time: 2019-07-0811:10:15 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-07-08 11:06:31 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: STEMMER RESIDENCE Calculation Date/Time: 11:05, Mon, Jul 08, 2019 Calculation Description: Title 24 Analysis Input File Name: 039 - 54575 AVENIDA VELASCO.ribd16x CF1 R-PRF-01 Page 9 of 9 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signaturr-- ARMANDO CHAVEZ Company: Signature Date: TITLE 24 OF THE DESERT 2019-07-08 11:09:23 Address: CEA/HERS Certification Identification (If applicable): 74800 Shirley #62 N.A. City/State/Zip: Phone: PALM DESERT, CA 92260 760-278-1840 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature- Ruben Romero Company: Date Signed: GLS ARCHITECTURE GROUP INC 2019-07-08 11:10:15 Address: License: 74491 JONI DR SUITE #9 N.A. City/State/Zip: Phone: Palm Desert, CA 92260 760-340-3528 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 219-P010108331B-000-000-0000000-0000 Registration Date/Time: 2019-07-08 11:10.15 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Easy to Verify HERS Provider: CaICERTS inc Report Generated at: 2019-07-08 11:06:31 'RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name STEMMER RESIDENCE Project Address 54575 AVENIDA VELASCO Building Type 53 Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration California Energy Climate Zone Total Cond. Floor Area Addition LA QUINTA CA Climate Zone 15 1,878 n/a Date 7/8/2019 # of Units 1 INSULATION Construction Type Cavit Area (ft2) Special Features Status Roof Wood Framed Attic Slab Unheated Slab -on -Grade Wall Wood Framed Door Opaque Door R 38 - no insulation R 15 - no insulation 1,878 Add=R-11.0 Cool Roof 1,878 Perim = 0' 1,536 Add=R-4.0 21 New New New New FENESTRATION Orientation Area ft2 Total Area: 276 Glazing Percentage- 14.8� NewfAltered Average U_Factor: U-Fac SHGC Overhang Sidefins Exterior Shades A•45 Status Right (N) 46.0 Front (E) 37.5 0.440 0.25 1.5 0.370 0.25 10.0 none Bug Screen none Bug Screen New New Front (E) 93.8 0.480 0.25 10.0 none Bug Screen New Left (S) 8.0 0.370 0.25 1.5 none Bug Screen New Left (S) 40.0 0.480 0.25 1.5 none Bug Screen New Rear (W) 5.0 0.440 0.25 1.5 none Bug Screen New Rear (W) 48.0 0.480 0.25 1.5 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC DISTRIBUTION Location Heating -Cooling Duct Duct Location R-Value Status HVAC Ducted WATER HEATING Qty. Type Ducted Attic 8.0 Gallons Min. Eff Distribution New Status 1 Small Storage Gas 50 0.58 Standard New EnergyPro 7.1 by Ener vSoft User Number: 20648 ID: 18-GLS1051 - 039 Page 12 of 17 2016 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. 'Exceptions may apply. (Original 08/2016 Building Envelope Measures: § 110.6(a)l: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfmlftl or less when tested per NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 101/l.S,21A440-2011." § 110.6(a)5: Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES 110.6-A and 110.E-13 for compliance and must be caulked and/or weatherstri ed.' § 110.7; Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material, § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 110.8 when the installation of a cool roof is specified on the CF1 R. § 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043. Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling.' § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-factor of 0.074 or § 150.0(c): less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembly! § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.' § 150.0(f): Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration; and, when installed as W of a heated slab floor, meet the requirements of § 11 0.8. § 150.0f9)1: Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This requirement also applies to controlled ventilation crawl spacefor buildings complying with the exception to § 150.0(d)_ § 150 0(gJ2. Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all insulation In all exterior walls vented attics, and unvented attics with air -permeable insulation. 150.0 § (q)' Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-factor of 0.58; or the weighted averse U-factor of all fenestration must not exceed 0.58.' Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)lA: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § i50.0(eJ1 B: Combustion Intake. Masonry or factory -built fireplaces musl have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -filling damper or combustion -air control device.' § 150.0(e)l C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0-§ 110.1 Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the Energy Commission.' § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heats is h' her than the cut-off temperature for supplementary heating.* § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat." Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. § 110.3(c)7: Isolation Valves. instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs or other fitti s on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed. § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- anceswithout an electrical supply voltage connection with pilot lights that consume less than 150 Btulhr are exem t);and pool and spa heaters.' Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)l: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J using design conditions specified in S 150.0(h)2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any dryer vent. § 150.0(h)3B: Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's instructions. § 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have _ R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures.' § 150,00)2B: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve." § 150.00)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution piping for steam and h dronic heating s stems or hot waters stems must meet the requirements in TABLE 120.3-A.` § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the material. § 150.00)3B: Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class II vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)1: 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150.0(n)3; Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation SRCC or by a listing agency that is approved L!Y the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certify to the customer, in writing,that the insulation meets this requirement. CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSIISMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)1: (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must bemechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than'/< inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts.' Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such toe is used in combination with mastic and draw bands. § 150.0(m)3. Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0 m 11 and Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure drop, and labeling requirements of § 150.0(m)12. 2016 Low -Rise Residential Mandatory Measures Summary Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central forced airs stems.' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(o): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providingwhole-building hole -building ventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testing. in accordance with Reference Residential Appendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.* § 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines or built-in or built-u connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover, § 110.4(b)3. Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. 150.0 § (p)' Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves.' Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9.' § 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must be certified to the Energy Commission according to Reference Joint Appendix JAB. § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms, These electrical boxes must be served by a dimmer, vacancy sensor control, or fanspeed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings. § 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)1 F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0 k .' Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1 G: with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix JA8." § 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E." § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G: functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5 ; and meets all other requirements in 4 150.0(k)2. Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5 f ; and all other requirements in 150.0(k)2. § 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it provides the funcUonalily of a dimmer according to § 110,g, and complies with all other applicable requirements in § 150.0(k)2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancy sensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JAB, exce t luminaires in closets less than 70 square feet and luminaires in hallways.' § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or EMCS. Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either § 150.0 k 3A or with the applicable requirements in §§ 110.9. 130.0. 130.2, 130.4. 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0 k 3B or§ 150.0 k 3D must comply with the applicable re uirements in §§ 110.9, 130.0. 130.2, 130.4, 140.7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehiclesper site must comply with the applicable requirements in §§ 110.9. 130.0. 130.2, 130.4. 140.7 and 141.0. § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of power as determined according to § 130.0(c). § 150.0(k)5; Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1. 130.4. 140.6, and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turninq the light fully on and off from all designed aths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the requirements of § 110.10 b through § 110.10 el. § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1: greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.' § 110,10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north, § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment.' Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane." § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system, § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110,10(b) through 1 10.10c must be provided to the occupant. § 110.10(e)l: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and permanently marked as "For Future Solar Electric". HVA(; SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name STEMMER RESIDENCE System Name HVAC _ Date 7/8/2019 Floor Area 1,878 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 819 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 84,000 18.086 1,976 317 14,628 Total Output Btuh 84,000 0 Output Btuhls ft 44.7 1.044 719 Cooling System 0 0 Output per System 60,000 0 0 0 0 Total Output Btuh 60,000 2,233 1,976 -2,233 Total Output Tons 5.0 1,044 719 Total Output (Btuh/s ft) 31.9 Total Output s ft/Ton 375.6 22,407 13,833 Air System CFM per System 1,835 HVAC EQUIPMENT SELECTION Airflow cfm 1,835 5 TON 80/14/11 44,853 5.632 84,000 Airflow cfm/s ft 0.98 Airflow cfm/Ton 367.0 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 44,853 5.632 84,000 Jan 1 AM Outside Air cfmis ft 0.00 Note: values above aiven at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF Outside Air 0 cfm AL 68 OF 69 OF 112 °F Heating Coil Supply Fan 1,835 cfm ROOM [3Fi COOLING SYSTEM PSYCHROMETRICS .Airstream Temperatures at Time of Cooling Peak Outside Air 0 cfm 76/61 OF 77 / 62 OF 54 / 52 OF 54 l 52 OF Cooling Coil Supply Fan 1,835 cfm 54 / 53 OF 44.8% ROOM 75/ EnergyPro 7.1 by EnergySoff User Number.- 20648 ID: 18-GLS/051 - 039 Page 17 of 17