BRES2019-017478-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Permit Type/Subtype:
Application Number:
Property Address:
APN:
Application Description
Property Zoning:
Application Valuation:
Applicant:
LUCASCORONEL
77935 CALLE TAMPICO #102
LA QUINTA, CA 92253
c&t�t44Q"
DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT
BUILDING RESIDENTIAL/ADDITION
BRES2019-0174
52640 AVENIDA NAVARRO
773305007
HACIENDA AGENCY INC / ADDITION & REMODEL
$30,000.00
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 11/22/2019
Owner:
HACIENDA AGENCY, INC.
77935 CALLE TAMPICO STE 201
LA QUINTA, CA 92253
aContractor:
PD CORONEL ENTERPRISES INC
NOV 2 2 201942760 MADIO STREET
INDIO, CA 92201
CITY OF LAQUINTA (760)775-1234
DESIGN &DEVEOPMENTDEPARTMENT LIc. No.:727199
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9
{commencing with Section 70001 of Division 3 of the Business and Professions Code, and
my License is in full force and effect.
License Class: j3 License No.: � �
Date:', — \ Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any
structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the
alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that he
or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to
construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State
License Law does not apply to an owner of property who builds or improves thereon,
and who contracts for the projects with a contractor(s) licensed pursuant to the
Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Narne:
Lender's Addres
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My workers' compensation insurance carrier and policy number are:
Carrier: BENCHMARK INSURANCE CQMPANY Policy Number: C,5T5014903
_ I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and a ree that, if I should become subject to the
workers' compensation provisions of S t 'on 370t
of the �atror Code, I all orthwith
comply with those provisions. l
Date: Lk - 7 -\ �_ Applican
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit issued
as a result of this application , the owner, and the applicant, each agrees to, and shall
defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not
commenced within 180 days from date of issuance of such permit, or cessation of work
for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of th ity t enter tt7
mentioned property for inspection purposes.
Date: {` w Signature (Applicant or Agent):
Date: 11/22/2019
Application Number:
BRES2019-0174
Property Address:
52640 AVENIDA NAVARRO
APN:
773305007
Application Description:
HACIENDA AGENCY INC / ADDITION & REMODEL
Property Zoning:
Application Valuation:
$30,000.00
Applicant:
LUCASCORONEL
77935 CALLE TAMPICO #102
LA QUINTA, CA 92253
Owner:
HACIENDA AGENCY, INC.
77935 CALLE TAMPICO STE 201
LA QUINTA, CA 92253
Contractor:
CORONEL ENTERPRISES INC
42760 MADIO STREET
INDIO, CA 92201
(760)775-1234
Ltc.-No.: 727199
Detail: 226 SF ADDITION TO LIVING SPACE, 628 SF OF REMODEL, AND RE -ROOF OF DWELLING. THIS INCLUDES NEW FENESTRATION, HVAC EQUIPMENT
AND A WATER HEATER. THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 2016 CALIFORNIA BUILDING CODES.
DESCRIPTION ACCOUNT QTY
101-0000-42600
DESCRIPTION ACCOUNT CITY
HOURLY CHARGE - ESGIL CIVIL ENGINEER 101-0000-42600 1.5
DESCRIPTION ACCOUNT QTY
HOURLY CHARGE - ESGIL CIVIL ENGINEER 101-0000-42600
DESCRIPTION
BSAS SB1473 FEE
DESCRIPTION
Credit Card Fee
DESCRIPTION
DEVICES, FIRST 20
DESCRIPTION
DEVICES, FIRST 20 PC
DESCRIPTION
DEVICES/FIXTURES, ADDITIONAL
DESCRIPTION
DEVICES/FIXTURES, ADDITIONAL PC
DESCRIPTION
SERVICES
DESCRIPTION
SERVICES PC
DESCRIPTION
CONDENSER/COMPRESSOR
DESCRIPTION
CONDENSER/COMPRESSOR PC
DESCRIPTION
EXHAUST HOOD
DESCRIPTION
EXHAUST HOOD PC
DESCRIPTION
FURNACE
DESCRIPTION
FURNACE PC
DESCRIPTION
VENT FAN
0
Total Paid for BLDG CITY STAFF - PER HOUR:
EACCOUNT CITY
-0000-20306 0
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA:
EEEACCOUNT CITY
101-0000-43505 0
Total Paid for Credit Card Fee:
ACCOUNT
CITY
101-0000-42403
0
ACCOUNT
CITY
101-0000-42600
0
ACCOUNT
CITY
101-0000-42403
0
ACCOUNT
CITY
101-0000-42600
0
ACCOUNT
CITY
101-0000-42403
0
ACCOUNT
CITY
101-0000-42600
0
Total Paid for ELECTRICAL:
ACCOUNT
CITY
101-0000-42402
0
ACCOUNT
CITY
101-0000-42600
0
ACCOUNT
CITY
101-0000-42402
0
ACCOUNT
QTY
101-0000-42600
0
ACCOUNT
QTY
101-0000-42402
0
ACCOUNT
CITY
101-0000-42600
0
ACCOUNT
CITY
101-0000-42402
0
AMOUNT
($124.50)
AMOUNT
$124.50
AMOUNT
$33.00
$33.00
AMOUNT
$2.00
$2.00
AMOUNT
$2.25
$2.25
AMOUNT
$26.68
AMOUNT
$26.68
AMOUNT
$53.40
AMOUNT
$13.40
AMOUNT
$26.68
AMOUNT
$13.34
$160.18
AMOUNT
$40.02
AMOUNT
$26.68
AMOUNT
$13.34
AMOUNT
$5.34
AMOUNT
$40.02
AMOUNT
$26.68
AMOUNT
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
VENT FAN PC
101-0000-42600
0
$10.68
Total Paid for MECHANICAL:
$189.44
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PLAN CHECK DEPOSIT - ADDITION/REMODEL
101-0000-42600
1
$125.00
Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL:
$125.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FIXTURE/TRAP
101-0000-42401
0
$66.70
DESCRIPTION
ACCOUNT
CITY
AMOUNT
FIXTURE/TRAP-PC
101-0000-42600
0
$66.70
DESCRIPTION
ACCOUNT
CITY
AMOUNT
GAS SYSTEM, 1-4 OUTLETS
101-0000-42401
0
$13.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
GAS SYSTEM, 1-4 OUTLETS PC
101-0000-42600
0
$26.68
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WATER HEATER/VENT
101-0000-42401
0
$13.34
DESCRIPTION
ACCOUNT
QTY
AMOUNT
WATER HEATER/VENT PC
101-0000-42600
0
$8.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WATER SYSTEM INST/ALT/REP
101-0000-42401
0
$13.34
DESCRIPTION
ACCOUNT
CITY
AMOUNT
WATER SYSTEM INST/ALT/REP PC
101-0000-42600
0
$13.34
Total Paid for PLUMBING FEES:
$221.44
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RECORDS MANAGEMENT FEE
101-0000-42416
0
7:]
$10.00
Total Paid for RECORDS MANAGEMENT FEE:
$10.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
REMODEL, EA ADDITIONAL 500 SF
101-0000-42400
0
$48.02
DESCRIPTION
ACCOUNT
CITY
AMOUNT
REMODEL, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$38.42
DESCRIPTION
ACCOUNT
CITY
AMOUNT
REMODEL, FIRST 100 SF
101-0000-42400
0
$54.43
DESCRIPTION
ACCOUNT
CITY
AMOUNT
REMODEL, FIRST 500 SF PC
101-0000-42600
0
$148.89
Total Paid for REMODEL:
$289.76
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RE -ROOF - FIRST 2,000 SF
101-0000-42404
0
$54.43
DESCRIPTION
ACCOUNT
CITY
AMOUNT
RE -ROOF - FIRST 2,000 SF PC
101-0000 42600
0
$108.87
Total Paid
for RE -ROOF:
$163.30
DESCRIPTION
ACCOUNT
CITY
AMOUNT
101-0000-42600
($0.50)
DESCRIPTION ACCOUNT
CITY
AMOUNT
SMI - RESIDENTIAL 101-0000-20308
0
$0.50
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $0.00
DESCRIPTION
ACCOUNT
CITY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
za Qa�fra
Al iFORNi_t --- -
Project Address: U /911[
APN #: '77�)3c — oo
Applicant Name:A1-.CI,z;4,&,6
Address: 7793sJ L £
City, ST, Zip: 7
Telephone:
Email: CaeeK
Contractor Name:
Address:
City, St, ZipCz
Telephone:
` v —
Email: liu Vet}cdr QL ",rto., t .c
State Lic: City Bus Lic:
Architect/Engineer Name:`QJr
Address: P,kol
City, St, Zip ._�� c ,r4 e -z Zip
Telephone: -� f s—
Email:�5w��-r r L� � a LR.. ,• r.. �.�..
State Lic: e City Bus Lic:
Property Owner's Name:
Address: '
City, ST, Zip z _
Telephone:
Email:
dC A,s fC /m, ri, ,d1
PERMIT # : IV(q—C) 1 7
f'LAIV LUL.A I lulu:
Project Description:
i d-AJ
77 Ce S
Valuation of Project D06 --�
New SFD Construction:
Conditioned Space
Garage
Patio/Porch
Fire Sprinklers
Construction
Grading:
Bedrooms: I Stories:
SF
SF
SF
SF
Occupancy:
# Units:
w Commercial / Tenant Improvements:
Total Building SF
Construction Type: Occupancy:
<%f C , C zc
78495 CALLE TAMPICO
LA QUINTA, CA 92253
760-777-7000
OFFICE USE ONLY
# Submittal Required Received
Plan Sets
l
Structural Calcs
Truss Calcs
Title 24 Calcs
Soils Report
Grading Plan (PM10)
Landscape Plan
Subcontractor List
Grant Deed
HOA Approval
School Fees
Burrtec Debris Plan
Planning approval
Public Works approval
Fire approval
City Business License
Date: 10/30/2019
No.: 19-01518-1
Owner: Hacienda Group
Address: 52640 Avenida Navarro
City: La Quinta
Type: Residential Addition < 500 sq ft
Lot # Street No
52640
Comments:
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
00%F11:0 S
a yn
47950 Dune Palms Road
ME.I.,�^°�Efi�
ru�aca enint� v
La Quinta, CA 92253
1- k{?lAr1 WE�IS �"
(760)771-8515
1�0[ 7.'[NDIO7A Y5•
Email:
Jurisdiction:
La Quinta
Tract #:
Street Name
Avenida Navarro
Sq. Feet APN Permit No.
226 773-305-007
RECEIVED
NOV 2 2 2019
CITY OF LA QUINTA
DESIGN AND DEVELOPMENT DEPARTMENT
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions
under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement
mobile homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
Exem pt
This certifies that school facility fess imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 226 S.F. or $0.00 have been paid for the property listed above and that building permits
and/or Certificates of Occupancy for this square footage in the proposed project may now be issued.
Fees Paid By: Err1Q11Cy Ro3ales Check No.: Bank Name/Recipient of Certificate Telephone:
Funding: Exempt
By Scott L. Bailey
Superintendent
Fee Collected/ Exempted by: Rodney Slagle
Certificate Fees Due:
Original Payment(s) Rec'd:
New Payment Rec'd:
Over/Under:
$0.00
$0.00
$0.00
$0.00
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you may protest the fees or
other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District(`s) behalf, whichever is earlier.
Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL.
RECORDING REQUESTED BY
Lawyers Title - IE
WHEN RECORDED MAIL THIS DOCUMENT
AND TAX STATEMENTS TO:
Hacienda -Agency , Inc.
Lucas'.Coronel, President
77935 Calle Tampico #201
La Quinta, CA 92253
DOC # 2019-0134185
04/19/2019 02:51 PM Fees: $17.00
Page 1 of 2
Recorded in Official Records
County of Riverside
Peter Aldana
Assessor -County Clerk -Recorder
'"This document was electronically submitted
to the County of Riverside for recording"
Receipted by: MARY #420
APN: 773-305-007-8 & 773-305-006-7
Escrow No: PDL17007-LT139-NB
Title No:
v
:�6.196r4' 0864
tl
I L ' w — 6 lq GRANT DEED Space above this line for Recorder's use
THE UNDERSIGNED GRANTOR(S) DECLARE(S)
DOCUMENTARY TRANSFER TAX IS $176.00,j
121 computed on full value of property conveyed
El City of La Quinta, AND
FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged,
James A. Pettigrew, a married man as his sole and separate property
hereby GRANT(S) to
Hacienda Agency Inc.
the following described real property in the County of Riverside, State of CALIFORNIA:
For legal description of the real property herein, see Exhibit A attached hereto and
made a part hereof.
Commonly known as: 52640 Avenida Navarro , La Quinta, CA 92253 and APN: 773-305-006-7, La Quinta
Date : Aril S.
®2019
J es A. Pettigrew
CA 92253
f A notary public or other officer completing this certificate verifies only the identity of the individual who signed the
document to which this certificate Is attached, and not the truthfulness, accuracy, or validity of that document.
STATE OF CALIFORNIA )
) SS.
COUNTY OF RIVERSIDE )
On April 12,E Z019 __ before me, _ Leticia L- Hernandez Notary Public, personally
appeared James A. Pettigrew
who proved to me on the basis of satisfactory evidence) to be the perso,, (s) whose name(" is/ a subscribed to
the within instrument and acknowledged to me that he/sheft�y executed the same in his/=r authorized
capacity(aes•), and that by his/hePAMir signature) on the instrument the person(A, or the entity upon behalf of
which the person) acted, executed the im... ent. //
I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true
and correct.
WITNESS my hand and official seal.
. �• , LETICIA L. HERNANDEZ
Notary Public - California x
Riverside County
F Commission x 2257383
Signatur -- My Comm. Expires Oct 1, 2022
DOC #2019-0134185 Page 2 of 2
Exhibit A
THE LAND REFERRED TO HEREIN IS SITUATED IN THE COUNTY OF RIVERSIDE, STATE OF
CALIFORNIA, AND IS DESCRIBED AS FOLLOWS:
LOT 17 AND 18 OF BLOCK 140 OF SANTA CARMELITA AT VALE LA QUINTA, UNIT NO. 15, IN THE CITY
OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA, AS PER MAP RECORDED IN BOOK 18,
PAGE 92 OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF RIVERSIDE COUNTY, CALIFORNIA.
ASSESSOR'S PARCEL NUMBER: 773-305-007-8 AND 773-305-006-7
Building Permit Number.
Project Description: SFR
,z
Exempt:
(Materials may contain hazardous wastes and
are not subject to recycling provisions)
of Construction Debris Management Plan
Plan Submittal
Job Site
Owners Name
Number, Street, or PO Box
City, State, Postal Code
Owner's Phone Number
Owner's E-Mall Address
10/10/2019
52640 AVE NAVARRO, LA QUINTA
HACIENDA GROUP
77935 CALLE TAMPICO, STE.201
LA QUINTA, CA. 92253
760-831-2008
A E ❑ INC -
Project Manager's Name LUCAS
Project Managers Phone Number 760-831-2008
Project Manager's E-mail Address I LUCASQtHACIE1`4(JAOI3OUAINC M Co
Bu Ider / Contra
Number, Street or PO
City, State, Postal C
Project Square Fool
Approval By Burrtec
Date of City Approval
CORONELENT
42760 MADIO ST
INDIO, CA.92201
226
Materials To Be Discarded:
Product
Tons
Trash
0.00
Not recyclable
Asphalt
0.00
Recyclable
Brick/Block
0.00
Recyclable
Cardboard
0.00
Recyclable
Commingled
0.00
Recyclable
Concrete
0.00
Recyclable
Drywall
0.00
Recyclable
Donated / Reuse"
O.Op
Recyclable
"Describe Items
Product
Tons
Masonry (broken)
0-C
Plaster
0,C
Scrap Metal
O.0
Tile (floor)
O.0
Tile (roo17
O.0
Wood
O.0
Landscape Debris
OX
Recyclable
Totals: Rec ate Trash Projected Diversion:
0-0 0.0 #DIV10!
I understand it is the property owner's responsibllity to submit copies of weight tickets or receipts to the District
Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the
Debris Management Plan (DMP) for the above named project shall guarantee that at least 65 % of the jobsite waste is
diverted from landrilling. The remaining material will be recycled or reused I will divert, for recycling or re -use, remaining
materials generated from the first day of the project through the completion of the project in accordance with this plan. This
DMP is issued in the name of the propertyowner(s) and shall remain their property throughout the construction and/or
demolition pro A contractor serving as agent weer may obtain a DMP for the owner. However, the DMP is still
i d in the na of the property owner(s) an the ow er relains legal responsibility for ensuring that the provisions of the
re adher . The pra ner{s] a d goneI contractor shall be kept informed of the diversion progress through
o rr,ty repp s If self-hau mg, all refuse m terlN fr this project site must be taken to an approved recycler or transfer
Own Developer! Projeet Manager I Suparintenrtanl Date
Z
LLJ
Ce
L.IL�
a
W
N
�
W
a
U'
�W
o �o
w
z o
z
Q
W
T-dy 4 4 auk&
P.O. Box 1504
LA QUINTA, CALIFORNIA 92247-1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
BUILDING & SAFETY DEPARTMENT
PROPERTY OWNER'S PACKAGE
(760) 777-7012
FAX (760) 777-7011
Disclosures & Forms for Owner -Builders Applying for Construction Permits
IMPORTANT! NOTICE TO PROPERTY OWNER
Dear Property Owner:
An application For a building permit has been submitted in your name listing yoursell' as the builder of the property
improvements specified at �z qc] v-4
We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of your
responsibilities and possible risk you may incur by having this permit issued in your name as the
Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision,
signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice
unless you, the property owner, obtain the prior approval of the permitting authority.
OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION
DIRECTIONS: Read and initial each statement below to signify you understand or verb this information.
I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder"
ding permit that erroneously implies that the property owner is providing his or her own labor and -material personally. 1, as
❑wner-Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person
and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those
injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers
on my property.
_ 22.. understand building permits are not required to be signed by property owners unless they are responsible for the
c ction and are not hiring a licensed Contractor to assume this responsibility.
_ I understand as an "Owner -Builder" I am the responsible party of record on the permit. I understand that I may protect
niy f from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my
own.
_ 4, I understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on
A 'ts and contracts.
i understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value
of y construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer"
un r state and Federal law.
__NG 1 understand if I am considered an "employer" under state and federal law, l must register with the state and federal
go nment, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment
compensati96 for each "employee." I also understand my failure to abide by these laws may subject me to serious financial
4sk.
. I understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential
ores cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed
ntractors and the number of structures does not exceed four within any calendar year, or all of the work is performed
under contract with a licensed general building Contractor.
8 undersland as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any
fin cial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the
workmanship or materials.
t 9 understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue
S ce, the United States Small Business Administration, the California Department of Benefit Payments, and the California
Division of Industrial Accidents. l also understand I may contact the California Contractors' State License Board (CSLB) at 1-
800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors.
m aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the
pa�fy leg l[y and financially responsible for proposed construction aq[ivity t the following address:
1. [agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all
jicaalbolle laws and requirements that govern Owner -Builders as well as employers.
. agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I
have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with
someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss
you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also
important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working
on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors,
you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers'
compensation insurance coverage.
Before a building permit can be issued, this form must be completed and signed by the property owner and returned to
the agency responsible for issuing the permit. Note: A copy of the properly oivner's driver's license, form notarization, or
other verification acceptable to the agent ' required to �bd when the permit is issued to verify the property
owner's signature. l
Signature of property owner Date: \1 l s
Note: The following Authorization Form is required to be completed by the property owner only when designating
an agent of the property owner to apply for a construction permit for the Owner -Builder.
AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF
Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize
the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder
Permit for my project.
Scope of Construction Project (or Description of Work): 5 —�pr ' - d � Za L- lk 7_26��,
Project Location or Address:
Name of Authorized Agent: .. sk ~e,/ Tel No �7, p — i5;-78 -3 3i -
Address of Authorized Agent:
I declare under penalty of perjury that I am the iroperly owner for the address listed above and l personally filled out the above
information and certify its accuracy. Note: A co y of the owner's driver's license, form notarization, or other verification
acceptable to the agency is required to be pre, led when the permit is issued to verify the properly owner's signature.
Property Owner's Signature: Date:---------------
���
CIENDA
GROUP, INQ
Real Estate • Finance L Commercial
s� my� /fie
RECEIVED
NOV 2 2 2019
CITY OF LA QUINTA
DESIGN AND DEVELOPMENT DEPARTMENT
77935 Calle Tampico, Suite 201 ♦ La Quinta, CA 92253 ♦ (760) 564-7514 Fax (760) 564-9874 ♦ Lucas@Hacienda group Inc. com
I BUILDING ENERGY ANALYSIS REPORT I
C � -T�l
'z.t3�q- o t1 H
Sz16k6
PROJECT:
Hacienda Group, Inc.
52640 Avenida Navarro - A.P.N.: 773-305-006
La Quinta, Ca 92253
Project Designer:
Santiago Lopez Ocampo - Drafting & Design
P.O. Box 1018
La Quinta, Ca 92247
760.485.8927
Report Prepared by:
SLO
Santiago Lopez-Ocampo
P.O. Box 1018
La Quinta, Ca 92247
760.485.8927
CITY OF LA OUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
DATE k-1+1120I�BYI -
Job Number:
LQ051619
Date:
5/16/2019
RECEIVED
MAY 2 8 2019
CRY OF fA QUINTA
DESIGN AND DEVELOPMENT DEPARTMENT
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards.
This program developed by EnergySoft Software — www.energysoft corn
I TABLE OF CONTENTS I
Cover Page 1
Table of Contents 2
Form CF-1 R-PRF-01-E Certificate of Compliance 3
Form RMS-1 Residential Measures Summary 11
Form MF-1 R Mandatory Measures Summary 13
HVAC System Heating and Cooling Loads Summary 17
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: 52640 Avenida Navarro Calculation Date/Time: 03:28, Thu, May 16, 2019
CFI R-PRF-01
Page 1 of 8
Calculation Description: Title 24 Analysis
Input File Name: 52640 Avenida Navarro.ribd16x
GENERAL INFORMATION
01
Project Name
52640 Avenida Navarro
02
Calculation Description
Title 24 Analysis
03
Project Location
52640 Avenida Navarro - A.P.N.: 773-305-006
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.3 1 (1149)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7 2
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
270
12
Project Scope
Addition and/or Alteration
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft)
984
15
Number of Zones
2
16
Slab Area (ft)
984
17
Number of Stories
1
18
Addition Cond. Floor Area (ftZ)
226
19
Natural Gas Available
No
LT71
Addition Slab Area (ftZ)
226
21
Glazing Percentage (%)
29.9%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater underthe supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ftZ-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
748
581
167
22.3%
Space Cooling
269.70
245.82
23.88
8.9%
IAQ Ventilation
0.00
000
0.00
0.0%
Water Heating
23.83
23.83
0.00
0.0%
Photovoltaic Offset
----
0.00
0.00
----
Compliance Energy Total
301.01
275.46
25.55
8.5%
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Non-standard roof reflectance
Registration Number: 219-P010112380A-000-000-0000000-0000 Registration Date/Time: 2019-05-16 03:51:39 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-05-16 03:29:49
CFI R-PRF-01
Page 2 of 8
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: 52640 Avenida Navarro Calculation Date/Time: 03:28, Thu, May 16, 2019
Calculation Description: Title 24 Analysis
Input File Name: 52640 Avenida Navarro.ribdl6x
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
--None--
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Verified Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
Domestic Hot Water System Verifications:
--None --
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Number of Dwelling
Number of Ventilation
Number of Water
Project Name
Conditioned Floor Area (ft2)
Units
Number of Bedrooms
Number of Zones
Cooling Systems
Heating Systems
52640 Avenida Navarro
984
1
3
2
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Existing
Conditioned
HVAC Systeml
' 758
8
DHW Sys 1
n/a
Addition
Conditioned
HVAC System1
226
8
DHW Sys 1
n/a
Registration Number: 219-P010112380A-000-000-0000000-0000 Registration Date/Time: 2019-05-16 03:51:39 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-05-16 03:29:49
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: 52640 Avenida Navarro Calculation Date/Time: 03:28, Thu, May 16, 2019
CFI R-PRF-01
Page 3 of 8
Calculation Description: Title 24 Analysis
Input File Name: 52640 Avenida Navarro.ribd16x
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
10
11
Name
Zone
Construction
Azimuth
Orientation
Gross Area
(ft)
Window & Door
Area (ftZ)
Tilt
(deg)
Wall
Exception
Status
Verified
Existing
Condition
Fr/W
Existing
Block Wall
270
Front
316.91
137.25
90
n/a
Existing
No
Le/N
Existing
Block Wall
0
Left
119.83
43.1
90
n/a
Existing
No
Re/E
Existing
Block Wall
90
Back
141.25
24.05
90
n/a
Existing
No
Ri/S
Existing
Block Wall
180
Right
206
36.1
90
n/a
Existing
No
Interior Surface
Existing»Addition
Block Wall1
175.58
0
n/a
Existing
No
Interior Surface 2
Existing»Addition
Block Wall1
86.08
0
n/a
Existing
No
Roof 2
Existing
R-38 Roof Attic
758
n/a
Altered
n/a
Le/N 2
Addition
R-21 Wall
0
Left
86.08
0
90
none
New
n/a
Re/E 2
Addition
R-21 Wall
90
Back
86.08
45.71
90
none
New
n/a
Roof 3
Addition
R-38 Roof Attic + RB - Sh
218
n/a
New
n/a
OPAQUE SURFACES — Cathedral Ceilings
01
02
03
04
05
06
07
08
09
10
11
12
Verified
Area
Skylight
Roof Rise
Roof
Roof
Cool
Existing
Name
Zone
Type
Orientation
(ft)
Area (ft2)
(x in 12)
Reflectance
Emittance
Roof
Status
Condifion
Roof
Addition
R-38 RoofAttic + RB
Left
8.1
8
3
018
0.9
No
New
n/a
ATTIC
01
02
03
04
05
06
07
08
09
10
Name
Construction
Type
Roof Rise
Roof
Reflectance I
Roof
Emittance
Radiant
Barrier
Cool
Roof
Status
Verified Existing
Condition
Attic Existing
Attic RoofExisting
Ventilated
3
0.18
0.9
No
No
Existing
No
Attic Addition
Attic RoofAddition
Ventilated
3
018
09
Yes
No
New
No
Registration Number: 219-P010112380A-000-000-0000000-0000 Registration Date/Time: 2019-05-16 03:51:39 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-05-16 03:29:49
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: 52640 Avenida Navarro Calculation Date/Time: 03:28, Thu, May 16, 2019
CFI R-PRF-01
Page 4 of 8
Calculation Description: Title 24 Analysis
Input File Name: 52640 Avenida Navarro.ribd 1 6x
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width (ft)
Height (ft)
Multiplier
Area (ft2)
U-factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
4042 Casement @ Bed
Fr/W (Front-270)
----
1
18.1
0.27
0.26
Insect Screen (default)
Altered
n/a
21064 Picture @ Living
Fr/W (Front-270)
----
----
1
17.9
0.28
0.33
Insect Screen (default)
Altered
n/a
3068 Fr.Dr. @ Entry
Fr/W (Front-270)
1
20.0
0.30
0.32
Insect Screen (default)
Altered
n/a
2864 Picture @ Living
Fr/W (Front-270)
-
1
16.9
0.28
0.33
Insect Screen (default)
Altered
n/a
21064 Picture @ Living 2
Fr/W (Front-270)
-
1
17.9
0.28
0.33
Insect Screen (default)
Altered
n/a
1464 Picture @ Living
Fr/W (Front-270)
----
1
8.4
0.28
0.33
Insect Screen (default)
Altered
n/a
6064 Casement @ Dining
Fr/W (Front-270)
----
-
1
38.0
0.27
0.26
Insect Screen (default)
Altered
n/a
4064 Picture @ Living
Le/N (Left-0)
-
-
1
25.3
0.28
0.33
Insect Screen (default)
Altered
n/a
2868 Fr.Dr. @ Dining
Le/N (Left-0)
-
1
17.8
0.30
0.32
Insect Screen (default)
Altered
n/a
3021 Casement @ Bath
Re/E (Back-90)
-
--
1
6.0
0.27
0.26
Insect Screen (default)
Altered
n/a
4042 Casement @ Bed2
Re/E (Back-90)
-
1
18.1
0.27
0.26
Insect Screen (default)
Altered
n/a
4042 Casement @ Bed2 2
Ri/S (Right-180)
--
-
1
18.1
0.27
0.26
Insect Screen (default)
Altered
n/a
4042 Casement @ Bed1 2
Ri/S (Right-180)
- -
--
1
18.1
0-27
0,26
Insect Screen (default)
Altered
n/a
8036 Casement @ Kitchen
Re/E 2 (Back-90)
----
-
1
28.0
0.27
0.26
Insect Screen (default)
New
n/a
3068 Fr.Dr. @ Laundry
Re/E 2 (Back-90)
1
17.7
0.30
0.32
Insect Screen (default)
New
n/a
2020 Skylight
Roof (Left-0)
-
----
1
4.0
0.42
0.32
None
New
n/a
2020 Skylight 2
Roof (Left-0)
----
----
1
4.0
0.42
0.32
None
New
n/a
Registration Number: 219-P010112380A-000-000-0000000-0000 Registration Date/Time: 2019-05-16 03:51:39 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-05-16 03:29:49
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: 52640 Avenida Navarro Calculation Date/Time: 03:28, Thu, May 16, 2019
CF1 R-PRF-01
Page 5 of 8
Calculation Description: Title 24 Analysis
Input File Name: 52640 Avenida Navarro.ribd16x
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-factor
Assembly Layers
• Cavity/Frame: no insul. /2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofExisting
Attic Roofs
Wood Framed Ceiling
in. O C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
Block Wall
Exterior Walls
Hollow Unit Masonry
0.671
Mass Layer: 6 in. NW CMU Solid Grout
Block Walll
Interior Walls
Hollow Unit Masonry
0.548
Mass Layer.' 6 in. NW CMU Solid Grout
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 24 in. O C
R 38
0.025
Over Ceiling Joists: R-28.9 insul.
• Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
• Roof Deck: Wood Siding/sheathing/decking
Attic RoofAddition
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
• Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
R-21 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in O.C.
R 21
0.069
• Exterior Finish: 3 Coat Stucco
• Inside Finish: Gypsum Board
Ceilings (below
• Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic + RB - Sh
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 38
0.025
• Over Ceiling Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-38 / 2x4
• Roof Deck: Wood Siding/sheathing/decking
R-38 Roof Attic + RB - Shl
Cathedral Ceilings
Wood Framed Ceiling
2x4 @ 24 in. O.0
R 38
0.036
• Roofing: Light Roof (Asphalt Shingle)
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ftZ)
Perimeter
(ft)
Edge Insul. R-value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Slab -on -Grade
Existing
758
0.1
None
0.8
No
Existing
No
Slab -on -Grade 2
Addition
226
0.1
None
0.8
No
New
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Not Required
Not Required
Not Required
n/a
Registration Number: 219-P010112380A-000-000-0000000-0000 Registration Date/Time: 2019-05-16 03:51:39 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-05-16 03:29:49
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: 52640 Avenida Navarro Calculation Date/Time: 03:28, Thu, May 16, 2019
CF1 R-PRF-01
Page 6 of 8
Calculation Description: Title 24 Analysis
Input File Name: 52640 Avenida Navarro. ribd 1 6x
WATER HEATING SYSTEMS
01
02
03
04
05
06 07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
M Status
Verified Existing
Condition
DHW Sys 1
DHW
Standard
DHW Heater 1
1
0 Altered
No
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Input Rating /
Tank
Standby
Heater
Tank
Uniform Energy
Pilot /
Insulation
Loss I
First Hour
Tank Location
Element
Number
Volume
Factor / Energy
Thermal
R-value
Recovery
Rating /
NEEA Heat Pump
or Ambient
Name
Type
Tank Type
of Units
(gal)
Factor / Efficiency
Efficiency
(Int/Ext)
Eff
Flow Rate
Brand / Model
Condition
DHW Heater 1
Gas
Small
Instantaneous
1
0
0 82 EF
<= 200 kBtu/hr
0
n/a
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
07
08
Distribution
Verified Existing
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Name
Status
Condition
HVAC Systeml
Heat Pump Heating and
Cooling System
Heat Pump System 1
Heat Pump System 1
HVAC Fan 1
Air Distribution
System
New
No
1
HVAC - HEAT PUMPS
01
02
03
04
I 05
06
07
08
09
10
11
Name
System
Type
Number of
Units
Heating
HSPF/COP Cap 47 Cap 17
Cooling
SEER EER
Zonally
Controlled
Compressor
Type
HERS
Verification
Heat Pump System 1
SplitHeatPump
1
9.5
60000
50000
157J 12.5
Not Zonal
Single Speed
Heat Pump System
1-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Heat Pump System 1-hers-cool
Required
350
Required
Required
Required
Registration Number: 219-P010112380A-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Registration DatefTime: 2019-05-16 03:51:39
Report Version - CF1 R-06232018-1149
HERS Provider: CaICERTS inc.
Report Generated at: 2019-05-16 03:29:49
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: 52640 Avenida Navarro Calculation DatelTime: 03:28, Thu, May 16, 2019
CF1 R-PRF-01
Page 7 of 8
Calculation Description: Title 24 Analysis
Input File Name: 52640 Avenida Navarro.ribd16x
HVAC - DISTRIBUTION SYSTEMS
01 02
03
04
05
06
07
08
09
10
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name Type
Duct Leakage
R-value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution Ducts located in attic
Air Distribution
System 1 (Ventilated and
Sealed and tested
8.0
Attic
Attic
None
New
No
System
Unventilated)
1-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
5-0
Not Required
Not Required
Not Required
Not Required
n/a
HVAC - FAN SYSTEMS & HERS VERIFICATION
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSG Furnace Fan
0.58
Required
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
0
0.25
Default
0
Not Required
Registration Number: 219-P010112380A-000-000-0000000-0000 Registration Date/Time: 2019-05-16 03:51:39 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149 Report Generated at: 2019-05-16 03:29:49
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: 52640 Avenida Navarro Calculation Date/Time: 03:28, Thu, May 16, 2019
Calculation Description: Title 24 Analysis Input File Name: 52640 Avenida Navarro.ribd16x
CF1 R-PRF-01
Page 8 of 8
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature
Santiago Lopez-Ocampo
Company:
Signature Date:
Santiago Lopez-Ocampo
2019-05-16 03:51:39
Address:
CEA/HERS Certification Identification (If applicable):
P.O. Box 1018
NA
City/State/Zip:
Phone:
La Quinta, CA 92247
760-485-8927
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3 The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signatured
Santiago Lopez-Ocampo
Company:
Date Signed:
Santiago Lopez-Ocampo
2019-05-16 03:51:39
Address:
License
P.O. Box 1018
NA
City/State/Zip:
Phone:
La Quinta, CA 92247
760-485-8927
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration
Provider responsibility for the accuracy of the information.
Easy to Verify
at CaICERTS.com
Registration Number: 219-P010112380A-000-000-0000000-0000 Registration DaterTime: 2019-05-16 03:51:39
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-06232018-1149
HERS Provider: CaICERTS inc
Report Generated at: 2019-05-16 03:29:49
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Hacienda Group, Inc.
Building Type
m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
5/16/2019
Project Address
52640 Avenida Navarro - A.P.N.: 773-305-
California Energy Climate Zone Total Cond. Floor Area
CA Climate Zone 15 984
Addition
226
# of Units
1
INSULATION
Construction Type
Cavity
Area
ft) Special Features Status
Slab Unheated Slab -on -Grade
- no insulation
758 Perim = 0'
Existing
Wall Hollow Unit Masonry
-
no insulation
180
Existing
Wall Hollow Unit Masonry
Demising Hollow Unit Masonry
- no insulation
- no insulation
77
176
Existing
Existing
Wall Hollow Unit Masonry
-
no insulation
117
Existing
Wall Hollow Unit Masonry
- no insulation
170
Existing
Roof Wood Framed Attic
R 38
758 Cool Roof
Altered
Demising Hollow Unit Masonry
- no insulation
86
Existing
FENESTRATION
Orientation Area ft2
Total Area: 294 Glazing Percentage: 29.9 %
U-Fac SHGC Overhang Sidefins
New/Altered Avera a U-Factor: 0.28
Exterior Shades Status
Front (W) 56.1
0.270
0.26 none
none
Bug Screen Altered
Front (W) 61.2
0.280
0.33 none
none
Bug Screen Altered
Front (W) 20.0
Left (N) 25.3
0.300
0.280
0.32 none
0.33 none
none
none
Bug Screen Altered
Bug Screen Altered
Left (N) 17.8
0.300
0.32 none
none
Bug Screen Altered
Rear (E) 52.1
0.270
0.26 none
none
Bug Screen Altered
Right (S) 36.1
0.270
0.26 none
none
Bug Screen Altered
Rear (E) 17.7
0,300
0.32 none
none
Bug Screen Altered
Skylight 4,0
0.420
0.32 none
none
None New
Skylight 4.0
0.420
0.32 none
none
None New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling
Min. Eff
Thermostat Status
1 Split Heat Pump 9.50 HSPF
HVAC DISTRIBUTION
Location Heating
Split Heat Pump 15.0 SEER
Cooling Duct Location
Setback New
Duct
R-Value Status
HVAC System Ducted
WATER HEATING
Qty. Type
Ducted Attic 8.0 New
Gallons Min. Eff Distribution Status
1 Small Instantaneous Gas
0
0.82
Standard
Altered
EnerqyPro 7.2 by EnergySoft User Number. 5732
ID: LQ051619 Pa a 11 of 17
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name Building Type m Single Family ❑ Addition Alone
Hacienda Group, Inc. ❑ Multi Family m Existing+ Addition/Alteration
Project Address California Energy Climate Zone Total Cond. Floor Area Addition
52640 Avenida Navarro - A.P.N.: 773-305 ° CA Climate Zone 15 984 226
Date
5/16/2019
# of Units
1
INSULATION Area
Construction Type Cavity (ft) Special Features
Status
Slab Unheated Slab -on -Grade - no insulation 226 Perim = 0'
Existing
Wall Wood Framed R 21 126
New
Roof Wood Framed Attic R 38 218 Cool Roof
New
FENESTRATION Total Area: 294 FGlaain Percentaq a 29.9 % New/Altered Average U-Factor:
Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades
0.28
Status
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat
Status
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R-Value
Status
WATER HEATING
-.Qty. Type Gallons Min. Eff Distribution
Status
EnergyPro 7.2 by Ene[gySoft User Number: 5732 ID: L0051619
Pa e 12 of 17
2016 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. "Exceptions may apply.
(Revised 04/20171
Building Envelope Measures:
§ 110.6(a)l
Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft' or less when tested per
NFRC-400 or ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-2011."
§ 110.6(a)5:
Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a).
§ 110.6(b):
Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES
110.6-A and 110.E-B for compliance and must be caulked and/or weatherstri ed.'
§ 110.7:
Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
asketed, or weather stripped.
§ 110.8(a):
Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material.
§ 110.8(g):
Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g).
§ 110.8(i):
Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing
material must meet the re uirements of § 11 0.8i when the installation of a cool roof is specified on the CF1 R.
§ 110.80):
Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043.
Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
§ 150.0(a):
insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited
to placing insulation either above or below the roof deck or on top of a drywall ceiling.'
§ 150.0(b):
Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value.
Above Grade Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-
§ 150.0(c):
factor of 0.074 or less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed
value of R-13 in a wood framed assembly.*
§ 150.0(d):
Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.'
§ 150.0(f):
Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light
deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8 .
§ 150.0(g)l:
Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This
requirement also applies to controlled ventilation crawl space for buildings complying with the exception to $150.0(d).
§ 150.0(g)2:
Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all
insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation.
150.0
§ (q)'
Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.'
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 150.0(e)lA:
Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)1 &
Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area
and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.'
§ 150.0(e)l C:
Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.'
§ 150.0(e)2:
Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of
the building, are prohibited.
Space Conditioning, Water Heating, and Plumbing System Measures:
§ 110.0-§ 110.3:
Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
appliances must be certified by the manufacturer to the Energy Commission.'
§ 110.2(a):
HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.`
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§ 110.2(b):
must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for
compression heating is higher than the cut-off temperature for supplementary heating.'
§ 110.2(c):
Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat.'
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
§ 110.3(c)5:
meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of §
110.3(c)5.
§ 110.3(c)7:
Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs
or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed.
§ 110.5:
Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli-
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt); and pool and spa heaters.'
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment
§ 150.0(h)l:
Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA
Manual J using design conditions specified in § 150.0(h)2.
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(h)3A:
Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any
dryer vent.
§ 150.0(h)3B:
Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by
manufacturer's instructions.
§ 150.00)1
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must
be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a
§ 150.00)2A:
nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter;
piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to
kitchen fixtures.'
_
§ 150.00)2B:
Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof
and non -crushable casing or sleeve.'
§ 150.00)2C:
Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution
piping for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.-
§ 150.00)3:
Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by
§ 150.00)3A:
aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can
cause degradation of the material.
§ 150.00)3B:
Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a
Class I or Class II vapor retarder.
Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a
§ 150.0(n)1:
120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside
termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr.
§ 150.0(n)2:
Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification
Corporation (SRCC) or by a listing agency that is approved by the Executive Director.
Ducts and Fans Measures:
§ 110.8(d)3:
Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a
contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement.
CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC
§§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or
a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing
§ 150.0(m)l:
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than'/< inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain
ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts.`
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
§ 150.0(m)2:
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such toe is used in combination with mastic and draw bands.
§ 150.0(m)3:
Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
mastics, sealants, and other requirements specified for duct construction.
§ 150.0(m)7:
Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
automatic dampers.
§ 150.0(m)8:
Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
§ 150.0(m)9:
wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation.
§ 150.0(m)10:
Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)l 1:
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with 6150.0(m)l land Reference Residential Appendix RA3.
Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,
pressure drop, and labeling requirements of § 150.0(m)l2.
Z2016 Low -Rise Residential Mandatory Measures Summary
Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable
space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the
§ 150.0(m)13:
supply plenum. The space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy _ 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central
forced airs stems.'
Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor
§150.0(o):
continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of
providing whole-buildinq ventilation.
§ 150.0(o)1A:
Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.7.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
§ 110.4(a):
that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heating.*
§ 110.4(b)1:
Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated
suction and return lines, or built-in or built-up connections to allow for future solar heating.
§ 110.4(b)2:
Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b)3:
Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
will allow all pumps to be set or programmed to run only during off-peak electric demand periods.
§ 110.5:
Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
150.0
§ (p)'
Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
rate, piping, filters, and valves.'
Lighting Measures:
§ 110.9:
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
of § 110.9.'
§ 110.9(e):
JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must
be certified to the Energy Commission according to Reference Joint Appendix JA8.
§ 150.0(k)1A:
Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or
§ 150.0(k)1 B:
other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fanspeed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)1 C:
labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C. A JA8-2016-E light source rated for
elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings.
§ 150.0(k)1 D:
Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than
20 kHz.
Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no
§ 150.0(k)1 E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled
by vacancy sensors.
§ 150.0(k)1 F:
Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
must meet the applicable requirements of § 150.0(k).'
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply
§ 150.0(k)1 G:
with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JAB-2016-E" as specified in Reference Joint Appendix
JA8.'
§ 150.0(k)1 H:
Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E."
§ 150.0(k)2A:
Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B:
Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.'
§ 150.0(k)2C:
Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually
switched ON and OFF.
§ 150.0(k)2D:
Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with
150.0(k).
§ 150.0(k)2F:
Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9,
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it:
§ 150.0(k)2G:
functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of §
130.5(f); and meets all other requirements in § 150.0(k)2.
Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the
§ 150.0(k)2H:
following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of §
130.5(f); and all other requirements in § 150.0(k)2.
§ 150.0(k)2L
Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(k)2J:
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
be controlled by a vacancy sensor.
§ 150.0(k)2K:
Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with
Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.*
§ 150.0(k)2L:
Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A:
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item
§ 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or
EMCS.
Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies,
§ 150.0(k)3B:
and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with
either § 150.0 k 3A or with the applicable requirements in §§ 110.9, 130.0, 130.2. 130.4. 140.7 and 141.0.
§ 150.0(k)3C:
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by
150.0 k 3B or § 150.0 k 3D must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)3D:
Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more
vehicles per site must comply witheplicable requirements in §§ 110.9. 130.0. 130.2, 130.4. 140.7, and 141.0.
§ 150.0(k)4:
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
power as determined according to § 130.0(c).
§ 150.0(k)5:
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
a plicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A:
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be high efficacy luminaires and controlled by an occupant sensor.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must:
§ 150.0(k)6B:
i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent. The occupant sensors must be capable of turning the Ii ht fullx on and off from all designed paths of ingress and egress.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1:
application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the
requirements of § 110.1 0b through § 110.10 e .
§ 110.10(a)2:
Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d).
Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local
jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet
each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas
§ 110.10(b)1:
greater than 10,000 square feet.
For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250
square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang
of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less
than 15 percent of the total roof area of the building excluding any skylight area.'
§ 110.10(b)2:
Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.*
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)3B:
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone, measured in the vertical lane.'
§ 110.10(b)4:
Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof
dead load and roof live load must be clearly indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for
§ 110.10(c):
routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system.
§ 110.10(d):
Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
110.10(c) must be provided to the occupant.
§ 110.10(e)1:
Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2:
breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or
main circuit location; and permanently marked as "For Future Solar Electric".
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Hacienda Group, Inc.
System Name
HVAC System
Date
5/16/2019
Floor Area
984
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,32E
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System 60,000
26,214
359
617
23,740
Total Output (Btuh)
j 60,000
0
Output Btuh/s ft
61,0
1,513
908
Cooling System
0
0
0
Output per System
36,000
0
0
0
Total Output (Btuh)
36,000
0
359
0
Total Output (Tons)
3•0
1,513
908
Total Output Btuh/s ft
36.6
Total Output s ft/Ton
328.0
1 29,240
25,556
Air System
CFM per System
1,000
HVAC EQUIPMENT SELECTION
Airflow (cfm)
1,000
High Efficiency Heat Pump
26,580
3,879
37,474
Airflow cfm/s ft
1.02
Airflow cfm/Ton
333.3
Outside Air %
0•0 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
26,580 3,8791 37,474
Aug 3 PM I Jan 1 AM
Outside Air cfm/s ft
0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS (Airstream
Temperatures at Time of Heating Peak
26 OF
Outside Air
0 cfm
67 OF
67 OF 105 IF 105 IF
f t% r'
LET-
Heating Coil Supply Fan
1,000 cfm
ROOM
68 OF
I -
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
112/73OF
Outside Air Ar 0 cfm AL
76 / 62 OF
76/62°F 55/54°F 55/54°F
lop
Cooling Coil Supply Fan 56 / 54 OF
1.000 cfm I ROOM
OOM
75 / 61 IF