BWFE2019-023878-495 CALLE TAMPICO DCII LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT Permit Type/Subtype: WALL/FENCE/SPECIAL/ENGINEERED DESIGN Application Number: BWFE2019-0238 Property Address: 54475 AVENIDA DIAZ APN: 774233026 Application Description: LENNOX / 80LF OF TREX INTERIOR SIDE YARD FENCING Property Zoning: Application Valuation: $5,800.00 Applicant: D CARLA EILEEN LENNOX &HUSSAIN MIRZA 54475 AVENIDA DIAZ LA QUINTA, CA 92253 NOV 18 2019 CITY OF LA QUINTA DESIGN & DEVELUPIAENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class:rrB License No.: 1030332 Date: l Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Na Lender's VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 11/18/2019 Owner: CARLA EILEEN LENNOX & HUSSAIN MIRZA 54475 AVENIDA DIAZ LA QUINTA, CA 92253 Contractor: HUITRON CONSTRUCTION CO 50427 RIGO CT COACHELLA, CA 92236 (760)457-9960 Llc. No.: 1030332 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the Work For which this permit is issued. I have and will maintain workers' compensation insurance, as required by Sect, 3700 of the Labor Cade, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: UNCHMA_RK INSURANCE CQME8NY _ Policy Number: CST5015396 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I all rthwith comply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. A I certify that I have read this application and state that a ab a infor atien is c I agree to comply with all city and county ordinances an slat laws rel ling to b construction, and hereby authorize representatives oft s cit o ente upon the mentioned property for inspection purposes. , Date: [l ►nature (Applicant or41 Date: 11/18/2019 Application Number: BWFE2019-0238 Property Address: 54475 AVENIDA DIAZ APN: 774233026 Application Description: LENNOX / 80LF OF TREX INTERIOR SIDE YARD FENCING Property Zoning: Application Valuation: $5,800.00 Applicant: CARLA EILEEN LENNOX & HUSSAIN MIRZA 54475 AVENIDA DIAZ LA QUINTA, CA 92253 Owner: CARLA EILEEN LENNOX & HUSSAIN MIRZA 54475 AVENIDA DIAZ LA QUINTA, CA 92253 Contractor: HUITRON CONSTRUCTION CO 50427 RIGO CT COACHELLA, CA 92236 (760)457-9960 Llc. No.: 1030332 Detail- 9OLF OF 6' TALL TREX 14ORIZONS FENCE [WAYNE MARKHAM BENNETT ENGINEERINQ]. TREX FENCING TO BE LOCATED WITHIN PROPERTY LINE PER SITE PLAN AND STRUCTURAL SECTION DETAIL. FENCING MATERIAL -SHALL NOT BE VISIBLE FROM STREET PER CITY OF LA QUINTA MUNICIPAL CODE SECTION 9.60.030(E). THE AREA BETWEEN THE BACK OF CURB AND ANY FENCING SHALL BR LANDSCAPED, HAVE A SUITABLE PERMANENT IRRIGATION SYSTEM, AND BE CONTINUOUSLY MAINTAINED BY THE PROPERTY OWNER: PER 2016 CALIFORNIA BUILDING CODES. FINANCIAL 1 • DESCRIPTION ACCOUNT CITY AMOUNT WALL/FENCE - FIRST 100LF 101-0000-42404 0 $53.67 DESCRIPTION ACCOUNT CITY AMOUNT WALL/FENCE - FIRST 100LF PC 101-0000-42600 0 $67.08 Total Paid for BLOCK WALL 2019: $120.75 DESCRIPTION ACCOUNT CITY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT CITY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 Total Paid for RECORDS MANAGEMENT FEE: $10.00 DESCRIPTION ACCOUNT CITY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 ta Qwkra CALIFORNIA PERMIT #�W FEZ 019 — Q 2 3 PLAN LOCATION: Project Address: r Project Description: Pool, Remodel, Add't, Elect, Plumb, Mech APN #: h Applicant Name: Address: City, ST, Zip: Telephone: Email: Valuation of Project $ 6,90 0 Contractor Name: D New SFD Construction: Address: v Conditioned Space SF City, St, Zip QV ��� Garage SF Telephone: Patio/Porch SF Email: v n ` vv\-Fire Sprinklers SF State Lic:- City Bus Lic: Arch/Eng Name: Construction Type: Occupancy: Address: Grading: City, St, Zip 3 Telephone: 9 Bedrooms: Stories: # Units: Email: dANIA State L41� ( 3;X City Bus Lic: Property Owner's Name: a F"j- Ccl New Commercial / Tenant Improvements: Address: r71 Total Building SF City, ST, Zip Construction Type: Occupancy; Telephone: Email: 7M95 CALLE TAMPICO LA QUINTA, CA 92253 (760)777-7125 W W W . LAQU I NTACA. GOV OFFICE USE ONLY # Submittal Req'd Rec'd Plan Sets Structural Calcs Truss Calcs Title 24 Calcs Soils Report Grading Plan (PM10) Landscape Plan Subcontractor List Grant Deed HOA Approval School Fees Burrtec Debris Plan Planning approval Public Works approval Fire approval City Business License m v N E N C ' - - - - Way Ily signed I Way f� ���� n nett F TREX HORIZONS COMPOSITE FENCE AT GRADE MPS q � 1.15 B e �� 08:39: 7' 0' ¢Q C41326+ (NON-STRUCTURAL DECORATIVE AT -GRADE BARRIER) * WHEn1 I ICGn Gne POOL A �.�..I d �) �! Q W ~ W W r a S OW O U' oW [ 6 L 1 0 Z 0 POST EP MANUF IN WELL' COMPACTED SOIL, TYP. 6' TREX HORIZONSI MATERIAL NEEDED FOR 8' SECTION 5 X 5 POST CAP PYRAMID, FLAT OR CROWN I 15" X 5" POST 1.5 " X 1.25" HORIZONTAL RAIL E�o U1 �J I 1"X5.75" INTERLOCKING PICKET :i a C .. V 1 717-11 rnITPE>I nrVrnlr- 6' TREX HORIZONSI MATERIAL NEEDED FOR 8' SECTION 0.875" X 1.5" VERTICAL BACK RAIL 0.5" X 1.5" VERTICAL FRONT RAIL 1.25" X 1.125" HORIZONTAL TOP RAIL BRACKET CITY OF LA QUINTA BUILDING DIVISION I REVIEWED FOR CODE CO PLIANCE DATE..'' 18 �9 ICY_ GENERAL NOTES ERTICAL FRONT AND ACK RAIL I 6' COMPOSITE FENCE SCALE:NTS DESIGN PRESSURE & REQUIRED FOOTER MOMENT POST POST VULT INSERT REQ HEIGHT SPA ING (MPH) REQUIRED? MOMENT (FT) (FT) (LB -FT) 6 8 1 95 NOINSERT 1756.8 E7 �OFCAOI tO / sir 1. THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE 2015 INTERNATIONAL BUILDING CODE & 2016 CALIFORNIA BUILDING CODE. 2. DESIGN BASED ON ASCE 7-10 USING V.It= 110-180 MPH (3 SEC GUST), EXPOSURE 'C', RISK CATEGORY I, USING THE SOLID SIGN METHOD, 0% OPEN USED IN CALCULATIONS. 3. THIS FENCE DESIGN TO BE USED AT GROUND SURFACE ONLY, WITH USE LIMITED TO DECORATIVE BARRIER PURPOSES ONLY. THIS FENCE IS NOT INTENDED TO MEET CODES GOVERNING ELEVATED BALCONIES OR STRUCTURAL RAILINGS. 4. COMPOSITE WOOD MATERIAL INFORMATION: ALL COMPOSITE WOOD MATERIAL TO HAVE A FLEX STR. OF 4000PSI MIN. 5. ALL CONCRETE AND EPDXY TO REACH A MIN. COMPRESSIVE STRENGTH OF 3000 PSI IN 7 DAYS. CONCRETE FOOTERS SHALL CONTAIN MINIMUM 0.1% FIBERMESH CONTENT PER CUBIC YARD. 6. THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALL MEMBERS FROM DISSIMILAR MATERIALS TO PREVENT ELECTROLYSIS. 7. SURROUNDING SOIL TO BE COMPACTED TO 98% OPTIMUM DENSITY, 2500 PSF MIN AND SHALL BE CLASSIFIED OR VERIFIED BY OTHERS PRIOR TO CONSTRUCTION AND SHALL BE SANDY GRAVEL CLASS ONLY. 8. POOL ACCESS GATES WHEN PROVIDED SHALL BE AT LEAST 48" ABOVE GRADE & EQUIPPED WITH A SELF CLOSING, SELF LATCHING LOCKING DEVICE NOT LESS THAN 54" FROM BOT OF GATE. GATE MUST OPEN OUTWARD AWAY FROM POOL & MUST HAVE NO OPENING >1/2" WITHIN 18" OF RELEASE MECHANISM. 9. ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY OTHERS. 10. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. 11. ANYTHING LESS THAN THE HEIGHT AND POST SPACING SHOWN HEREIN MAY BE AS PER MANUFACTURER PLANS FOR DIMENSIONAL CONFORMITY, PROVIDED COMPONENTS AND EXTRUSIONS ARE PER THIS DESIGN AND THERE ARE NO INCREASED TRIBUTARIES. 12. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. 13. ENGINEERING EXPRESS HAS NOT VISITED THIS ]OBSITE. INFORMATION CONTAINED HEREIN IS BASED ON CONTRACTOR SUPPLIED DATA AND MEASUREMENTS. USE OF THIS DOCUMENT BY THE END USER CONSTITUTES ACCEPTANCE THAT THE SIGNING ENGINEER, AND ENGINEERING EXPRESS, SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS. WORK SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. ENGINEERING EXPRESS SHALL BE I NOTIFIED AND GIVEN AN OPPORTUNITY TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION PRIOR TO MODIFICATION OF EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS. SIGNATURE ON SHEET 1, THIS SHEET IS PART OF A DIGITALLY SIGNED FILE, SHALL REMAIN IN DIGITAL FORMAT, & PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED. IF THERE IS NO DIGITAL SIGNATURE ON SHEET 1 OR THIS SHEET DOES NOT CONTAIN AN ENGINEER'S ORIGINAL SIGNATURE & SEAL, t7 N W ¢ n awe H L Cc) IY co I O Z=In W LLJ m m = o z U Co f � W ID Lu z LU co � w Z a Q Z W 3Gow ­1 ­1 (D)E c p U" D1 cc n, U V/ C L � X 0• z Q co � E U O U a g Z O 0. LU > z N w Q CY �g OR LU It LL Lr) �aa zoNoo a- z : o�ozow w ?o �owz'w daw'mg r�owa Nmwo= z mezzo¢ U q Io Nwr woo¢ �a3�a {a 19-18480 „ 1 SCALE: NTS UNLESS NOTED 3 1.5 " X 1.25" I RAIL BRACKET ATTACHMENT 2 SCALE: NTS DETAIL L 0 m m U LL E v E 6 0 m 1.25" X 1.125" HORIZONTAL TOP RAIL BRACKET ATTACH BRACKET TO POST WITH (2) #8 SMS 0.5" X 1.5" VERTICAL FRONT RAIL ATTACH RAIL BRACKETS TO POST WITH #8 SMS AT EACH ANCHOR LOCATION (5 PER EACH VERTICAL RAIL, MIN) 0.5" X 1.5" VERTICAL FRONT RAIL 1.5 " X 1.25" HORIZONTAL RAIL LEVATION VIEW OF THE POST CALE: NTS DETAIL 1.25" X 1.125" L'7RIZONTAL TOP RAIL :ACKET MA Q EN0/ Q� KBRM��lp C41326 m y CIVIC �P OFCAOI 875" X 1.5" VERTICAL kCK RAIL 1"X5.75" INTERLOCKING PICKET RAIL BRACKET SECTION 7 SCALE: NTS DETAIL ]TING AT TREX POST 4 TOP VIEW OF THE POST 2 SCALE: NTS DETAIL IF THIS NATURE ON SHEET 1, THIS :ET IS PART OF A DIGITALLY WED FILE, SHALL REMAIN IN ATAL FORMAT, & PRINTED PIES OF THIS DOCUMENT E NOT CONSIDERED SIGNEI D SEALED. IF THERE IS NO ;ITAL SIGNATURE ON SHEET 1 THIS SHEET DOES NOT VTAIN AN ENGINEER'S IGINAL SIGNATURE & SEAL, N W Q d Lu � m In �o W m 0 Z=M W w 00 LL. m m = 00 Z U FNwko W Lu co zu,za Q Z LU 3 Ln "w '-4-1 0) E c o u U gC ^, c VJ c LL Z Q � � U Lu U p Q gLuZ w>5 Iraq Lu Q)P U LL Ln W H NS -O C 2 0 W 3 Q EE Z Z !C S m w�a= o- O :J LL iooic� zp�0 0-oz U i W U W Z U r ¢ O w > W Z Z C Z ONy�j O� W o �<3sa 19-18480 SCALE: NTS UNLESS NOTED -i?::WFCZOIci- 023o G CrY RECEIVED NOV 1 � 2019 CM OF LA QUINTA DESIGN AND DEVELOPMENT DEPARTMENT k ,z 1� M � O c� l30 LA