Loading...
0209-003 (SFD) Compaction Reportn iInformation � ®ToBuild On Engineering • Consuiting • Testing REPORT OF FIELD COMPACTION TESTS TESTED FOR: MIKE DIAZ PROJECT: 51-265'CALLE RHONDO PO BOX 1595 LA QUINTA, CA LA QUINTA, CA 92253 • +- 1 ^ DATE: December 18, 2000 OUR REPORT NO.:073-00350-2 TEST DATA: (1) Fine to medium grained silty sand. OPT. MOIST. = 12.0% TEST NO. TEST DEPTH ELEVATION : SOIL ID NUMBER MAXIMUM LAB DRY t DENSITY WATER CONTENT WET DENSITY DENSITY P=RCENT COMPACTION COMMENTS' Spec. 9.0% Min 1 811. FG 1 118.0 10.4 123.9 112.2 95.1 1 - A 2 811 FG 1 118.0 10.9 125.3 113.0 95.8 1 - A 3 811 FG. 1 118.0 10.2 125.6 114.0 96.6 1 - A 4 811 FG 1 118.0 10.5 125:2 113.3 :96.0 1 - A r, r• r TEST LOCATION: House pad. 1 NE corner. 2 NW corner. 3 SW corner. . 4 SE corner. NOTES: TESTS PERFORMED PER ASTM D2922-96 & ASTM D3b17-96 'COMMENTS: 1. FILL MATERIAL A. TEST RESULTS COMPLY WITH SPECIFICATIONS DENSITIES SHOWN: Lbs. per cubic foot 2. BACKFILL B. PERCENT COMPACTION DOES NOT COMPLY WATER CONTENT: Percent of dry weight. 3. BASE COURSE . WITH SPECIFICATIONS PERCENT COMPACTION: Based on maximum dry 4. SUBBASE C., RETEST OF PREVIOUS TEST density obtained on sample indicated by 5. SOIL CEMENT D. MOIS—URE IN EXCESS OF SPECIFICATIONS soil ID number. 6. OTHER E. ,MOIS . URE BELOW SPECIFICATIONS * (1) ASTM D-1557, Procedure A TEST INSTRUMENT: STANDARD COUNT M: D: REMARKS: PSI did not monitor the material placement. ADJUSTMENT DATA M: D: Respectfully submitted, TECHNICIAN: Juan Nunez Professional Service Industries, Inc. THESE TEST RESULTS APPLY ONLY TO THE SPECIFIC LOCATIONS NOTED AND MAY NOT REPRESENT ANY OTHER LOCATIONS OR ELEVATIONS. W REPORTS MAY NOT BE REPRODUCED. EXCEPT IN FULL, WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES. INC. �-= Professional Service Industries, Inc. • 42-240 Green Way, Suite C • Palm Desert, CA 92211 • Phone 760/341-5796 • Fax 760/341-5794 PSI A•100.2�4)F